Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 97(3): E425-E430, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-32681697

RESUMEN

OBJECTIVE: To compare post-procedural outcomes of trans-catheter valve replacement (TAVR) among safety-net (SNH) and non-safety net hospitals (non-SNH). BACKGROUND: SNH treat a large population of un-insured and low income patients; prior studies report worse outcome at these centers. Results of TAVR at these centers is limited. METHODS: Adults undergoing TAVR at hospitals in the US participating in the National In-patient sample (NIS) database from January 2014 to December 2015 were included. A 1:1 propensity-matched cohort of patients operated at SNH and non-SNH institutions was analyzed, on the basis of 16 demographic and clinical co-variates. Main outcome was all-cause post-procedural mortality. Secondary outcomes included stroke, acute kidney injury and length of post-operative stay. RESULTS: Between 2014 and 2015, 41,410 patients (mean age 80 ± 0.11 years, 46% female) underwent TAVR at 731 centers; 6,996 (16.80%) procedures were performed at SNH comprising 135/731 (18.4%) of all centers performing TAVR. SNH patients were more likely to be female (49% vs. 46%, p < .001); admitted emergently (31% vs. 21%; p < .001; at the lowest quartile for household income (25% % vs. 20%; p < .001) and from minorities (Blacks 5.9% vs. 3.9%; Hispanic 7.2% vs. 3.2%).Adjusted logistic regression was performed on 6,995 propensity-matched patient pairs. Post-procedural mortality [OR 0.99(0.98-1.007); p = .43], stroke [OR 1.009(0.99-1.02); p = .08], acute kidney injury [OR 0.99(0.96-1.01); p = .5] and overall length of stay (6.9 ± 0.1 vs. 7.1 ± 0.2 days; p = .57) were comparable in both cohorts. CONCLUSION: Post-procedural outcomes after TAVR at SNH are comparable to national outcomes and wider adoption of TAVR at SNH may not adversely influence outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Catéteres , Femenino , Mortalidad Hospitalaria , Humanos , Tiempo de Internación , Masculino , Complicaciones Posoperatorias , Factores de Riesgo , Proveedores de Redes de Seguridad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 93(3): 545-552, 2019 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-30312990

RESUMEN

OBJECTIVES: This study reports on the clinical effects of complete vs incompletely revascularized coronary artery disease on transcatheter aortic valve replacement (TAVR). BACKGROUND: There is a high prevalence of active coronary artery disease (CAD) in patients undergoing TAVR but preemptive revascularization remains controversial. METHODS: Patients were categorized into three cohorts: complete revascularization (CR), incomplete revascularization of a major epicardial artery (IR Major), and incomplete revascularization of a minor epicardial artery only (IR Minor). When feasible, SYNTAX scoring was performed for exploratory analysis. Analyses were performed using Cox proportional hazard models and Kaplan-Meier method. RESULTS: A total of 323 patients with active CAD were included. Adjusted outcomes showed that patients with IR Major had increased incidence of acute myocardial infarction (AMI) or revascularization compared with those in the CR cohort (HR 3.72, P = 0.048). No difference was noted in all-cause mortality or all-cause readmission rates. Exploratory secondary analysis with residual SYNTAX scores showed a significant interaction between disease burden and AMI/revascularization, as well as all-cause readmission. All-cause mortality remained unaffected based on residual SYNTAX scores. CONCLUSIONS: This is a retrospective single-center study reporting on pre-TAVR revascularization outcomes in patients with active CAD. In this analysis, we found that patients undergoing TAVR benefited from achieving complete revascularization to abate future incidence of AMI/revascularization. Despite this finding, all-cause mortality remained unaffected. Future efforts should focus on the role of functional assessment of the coronaries, as well as the long-term effects of complete revascularization in a larger patient cohort.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Cateterismo Periférico , Enfermedad de la Arteria Coronaria/terapia , Arteria Femoral , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Causas de Muerte , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Humanos , Masculino , Readmisión del Paciente , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Punciones , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
3.
Heart Lung Circ ; 28(12): 1896-1903, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30528815

RESUMEN

BACKGROUND: Re-admission is an important source of patient dissatisfaction and increased hospital costs. A simple calculator to determine the probability of re-admission may help guide patient dismissal planning. METHODS: Using the national readmissions database (NRD), we identified admissions for isolated primary coronary artery bypass (CABG) and stratified them according to 30-day readmission. Including pre, intra and postoperative variables, we prepared a logistic regression model to determine the probability for re-admission. The model was tested for reliability with boot-strapping and 10-fold cross-validation. RESULTS: From 135,699 procedures, 19,355 were readmitted at least once within 30days of dismissal. Patients who were readmitted were older (67±10 vs 65 ± 10 years, p<0.01), females (32% vs 24%; p<0.01) and had a higher Elixhauser comorbidity score (1.5±1.4 vs 1.1±1.2; p<0.01). Our final model (c- statistic=0.65) consisted of 16 pre and three postoperative factors. End-stage renal disease (OR 1.79 [1.57-2.04]) and length of stay>9days (OR 1.60 [1.52-1.68]) were most prominent indicators for readmission. Compared to Medicaid beneficiaries, those with private insurance (OR 0.62 [0.57-0.68]) and Medicare (OR 0.85 [0.79-0.92]) coverage were less likely to be readmitted. CONCLUSIONS: Our simple 30-days CABG readmission calculator can be used as a strategic tool to help reduce readmissions after coronary artery bypass surgery.


Asunto(s)
Toma de Decisiones Clínicas , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/economía , Bases de Datos Factuales , Medicaid/economía , Readmisión del Paciente/economía , Anciano , Comorbilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Medición de Riesgo , Estados Unidos
4.
Catheter Cardiovasc Interv ; 91(2): 345-353, 2018 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-28836345

RESUMEN

OBJECTIVE: Determine the feasibility and predictors of early discharge after minimalist transcatheter aortic valve replacement (TAVR). BACKGROUND: Duration of hospitalization has a direct impact on overall cost of care, but the clinical impact of length of stay (LOS) in patients undergoing minimalist TAVR remains unclear. METHODS: We studied 268 patients who underwent minimalist TAVR. Short LOS (sLOS) was defined as post-procedural LOS ≤ 3 days and observed in 163 patients. Prolonged LOS (pLOS) was observed in 105 patients. Propensity score matching based on 39 variables yielded 54 pairs of patients in each group. We analyzed 30-day mortality, 30-day re-hospitalization and long-term survival data. Multivariate regression models were used to define predictors of sLOS. RESULTS: Thirty-day mortality was 0% versus 5.5% in the sLOS and pLOS groups, respectively (P = 0.08). Incidence of re-hospitalization was higher in pLOS (13% vs. 3.7%). sLOS was associated with lower odds ratio of minor vascular complication (OR 0.1 [95% CI: 0.01, 0.75], P = 0.05), any bleeding (OR 0.35 [95% CI: 0.14, 0.87], P = 0.02), blood transfusion (OR 0.27 [95% CI: 0.08, 0.81], P = 0.02), and new pacemaker implantation (OR 0.23 [95% CI: 0.1, 0.53], P < 0.001). Discharge to home had a significantly higher odd ratio for sLOS (OR 8.67 [95% CI: 3.59, 23.11], P < 0.001). CONCLUSION: In appropriately selected patients, sLOS following minimalist TAVR approach in an experienced and high volume center is feasible and safe. Implementing such a strategy may reduce medical costs with the potential clinical benefit of early re-habilitation for the elderly TAVR population.


Asunto(s)
Válvula Aórtica/cirugía , Tiempo de Internación , Alta del Paciente , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Toma de Decisiones Clínicas , Estudios de Factibilidad , Femenino , Humanos , Masculino , Readmisión del Paciente , Seguridad del Paciente , Selección de Paciente , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
5.
J Card Surg ; 33(6): 316-321, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29726039

RESUMEN

BACKGROUND AND AIM: We examined the relationship between serum lactate and hemoglobin levels on renal function and postoperative outcome in low-risk elective coronary artery bypass graft (CABG) patients. METHODS: Intraoperative hemoglobin and lactate levels were measured in elective isolated CABG patients. Patients with renal dysfunction (baseline creatinine>2 mg/dL) were excluded. Multivariate logistic regression was used to determine associations between lactate, hemoglobin, and acute kidney injury (AKI). RESULTS: A total of 375 patients met study requirements, and 56/375 (15%) developed AKI. Of the patients who developed AKI, 43/278 (15.5%) were males, 13/97 (13.4%) females, and 11/44 (25%) African-Americans. Bivariate analysis between AKI and non-AKI subgroups found significant differences in age, race, baseline estimated glomerular filtration rate, preoperative hemoglobin, peak serum lactate, initial hemoglobin, and nadir hemoglobin. A high peak Lactate level (odds ratio [OR] 1.44[1.15-1.82]), low hemoglobin (OR 0.69[0.49-0.96]), and African American race (OR 2.26[0.96-5.05]) were independently associated with acute kidney injury. A significant relationship between decreasing intraoperative hemoglobin and increasing intraoperative serum lactate levels was observed exclusively in patients who developed postoperative AKI. Serum creatinine levels peaked, on average, 48 h postoperatively in the AKI subset of patients. CONCLUSION: In this series, 15% of patients who underwent elective cardiopulmonary bypass developed transient acute renal dysfunction. High lactate levels and low hemoglobin levels during cardiopulmonary bypass were associated with an increased risk of kidney injury.


Asunto(s)
Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/etiología , Puente de Arteria Coronaria , Procedimientos Quirúrgicos Electivos , Hemoglobinas , Lactatos/sangre , Complicaciones Posoperatorias/diagnóstico , Lesión Renal Aguda/epidemiología , Adulto , Anciano , Biomarcadores/sangre , Puente Cardiopulmonar , Femenino , Tasa de Filtración Glomerular , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Grupos Raciales , Riesgo , Factores Sexuales
7.
Circulation ; 132(22): 2108-17, 2015 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-26499963

RESUMEN

BACKGROUND: The mechanism(s) of persistent and long-standing persistent (LSP) atrial fibrillation (AF) is/are poorly understood. We performed high-density, simultaneous, biatrial, epicardial mapping of persistent and LSP AF in patients undergoing open heart surgery (1) to test the hypothesis that persistent and LSP AF are due to ≥ 1 drivers, either focal or reentrant, and (2) to characterize associated atrial activation. METHODS AND RESULTS: Twelve patients with persistent and LSP AF (1 month to 9 years duration) were studied at open heart surgery. During AF, electrograms were recorded from both atria simultaneously for 1 to 5 minutes from 510 to 512 epicardial electrodes with ECG lead II. Thirty-two consecutive seconds of activation sequence maps were produced per patient. During AF, multiple foci (QS unipolar atrial electrograms) of different cycle lengths (mean, 175 ± 18 ms) were present in both atria in 11 of 12 patients. Foci (2-4 per patient, duration 5-32 s) were either sustained or intermittent, were predominantly found in the lateral left atrial free wall, and likely acted as drivers. Random and nonrandom breakthrough activation sites (initial r or R in unipolar atrial electrograms) were also found. In 1 of 12 patients, only breakthrough sites were found. All wave fronts emanated from foci and breakthrough sites, and largely either collided or merged with each other at variable sites. Repetitive focal QS activation occasionally generated repetitive wannabe reentrant activation in 5 of 12 patients. No actual reentry was found. CONCLUSIONS: During persistent and LSP AF in 12 patients, wave fronts emanating from foci and breakthrough sites maintained AF. No reentry was demonstrated.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Mapeo Epicárdico/instrumentación , Mapeo Epicárdico/métodos , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/cirugía , Electrodos , Técnicas Electrofisiológicas Cardíacas/instrumentación , Técnicas Electrofisiológicas Cardíacas/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo , Ultrasonografía
8.
Catheter Cardiovasc Interv ; 88(7): E233-E238, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26268544

RESUMEN

Surgical mitral annuloplasty ring failure can result in symptomatic mitral stenosis or regurgitation which carries significant morbidity and mortality. Reoperation carries high surgical risks and the feasibility of transcatheter mitral valve-in-ring implantation is suggested by several case reports and series. In this article, we report two MVIR procedures focusing on preprocedural planning issues and intraprocedural tips. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral/métodos , Insuficiencia de la Válvula Mitral/terapia , Estenosis de la Válvula Mitral/terapia , Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/instrumentación , Angiografía por Tomografía Computarizada , Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Hemodinámica , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Anuloplastia de la Válvula Mitral/efectos adversos , Anuloplastia de la Válvula Mitral/instrumentación , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/fisiopatología , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/etiología , Estenosis de la Válvula Mitral/fisiopatología , Diseño de Prótesis , Falla de Prótesis , Retratamiento , Resultado del Tratamiento
9.
J Card Surg ; 31(8): 507-14, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27389823

RESUMEN

BACKGROUND: Valve selection in patients with end-stage renal disease (ESRD) is uncertain. We performed a systematic review and meta-analysis to compare clinical outcome in ESRD patients undergoing valve replacement. METHODS: We systematically searched multiple databases (2000-October 2015) to identify original studies comparing adverse events between mechanical and biological valve replacement in ESRD patients. End-points studied were: postoperative mortality, bleeding events, need for re-operation, and late survival. A random-effect inverse-variance weighted analysis was performed; event rates are compared as odds ratio (OR and 95% confidence interval) and hazard ratios (HR) for time-to-event data. Mechanical valve and tissue valve replacement were considered as study and control cohorts, respectively. RESULTS: Fifteen retrospective studies (5523 mechanical and 1600 tissue valve) were included in our meta-analysis. Early mortality was comparable (OR 1.15 [0.77; 1.72]; p = 0.49). The mean follow-up among studies ranged from 1.6-15 years. Bleeding was significantly higher after mechanical valve replacement (OR 2.55 [1.53; 4.26]; p = 0.0003). Structural valve degeneration was present in only 0.6% patients after a tissue valve replacement. Overall survival after valve replacement was poor (median 2.61 years); valve choice did not influence this outcome (pooled HR 0.87 [0.73; 1.04]; p = 0.14). CONCLUSION: Operative mortality in ESRD patients is comparable between mechanical and tissue valve replacement. Major bleeding episodes are significantly higher after mechanical valve replacement but structural degeneration in tissue valves during the follow-up period is low. Based on the findings from this meta-analysis, we would recommend using tissue valves in patients with ESRD.


Asunto(s)
Bioprótesis , Enfermedades de las Válvulas Cardíacas/cirugía , Válvulas Cardíacas/trasplante , Fallo Renal Crónico/complicaciones , Enfermedades de las Válvulas Cardíacas/complicaciones , Prótesis Valvulares Cardíacas , Humanos , Diseño de Prótesis , Estudios Retrospectivos
10.
Heart Surg Forum ; 19(1): E16-22, 2016 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-26913679

RESUMEN

BACKGROUND: Renal dysfunction is a common complication after cardiovascular surgery. Controversial issues have been discussed regarding the role of N-acetyl cysteine in the prevention of postoperative renal dysfunction. The purpose of this meta-analysis is to assess whether N-acetyl cysteine offers any protection against the development of acute renal dysfunction after cardiac surgery. METHODS: Multiple databases were searched for randomized trials comparing the role of N-acetyl cysteine and placebo in human patients undergoing cardiac surgery. End-points studied were: the incidence of acute renal failure, hemodialysis, early mortality, duration of hospital stay, and maximal change in creatinine values. Dichotomous variables were compared using the risk difference (RD) calculated with inverse weighting; continuous data was pooled as (standardized) mean difference. Results are presented with 95% confidence interval (P < .05 is significant); results are presented within 95% confidence interval. RESULTS: Thirteen randomized trials (713 and 707 patients in the N-acetyl cysteine and control groups, respectively) were included in the present analysis; nine dealing with patients at high-risk for acute renal failure. The incidence of postoperative acute renal dysfunction was 23% and 36% in the N-acetyl cysteine and control cohorts, respectively. N-acetyl cysteine therapy did not reduce acute renal dysfunction in the high-risk cohort [RD -0.03 (-0.09 to 0.02); P = .22; I2 = 24%]. Maximal change in creatinine levels after surgery was also comparable [standardized mean difference 0.07 (-0.23, 0.09); P = .39]. Early mortality was 2.9% and 3.7% in the N-acetyl cysteine and control cohorts respectively; [RD 0 (-0.03 to 0.02); P = .63; I2 = 20%]. Hospital stay (mean length of stay 10.4 and 10.1 days in the N-acetyl cysteine and control cohorts, respectively) was also similar in both cohorts [WMD 0.17 (-0.02 to 0.37) days; P = .81]. CONCLUSION: Prophylactic N-acetyl cysteine therapy does not reduce the incidence of renal dysfunction in high-risk patients undergoing cardiac surgery.


Asunto(s)
Acetilcisteína/uso terapéutico , Lesión Renal Aguda/mortalidad , Lesión Renal Aguda/prevención & control , Procedimientos Quirúrgicos Cardíacos/mortalidad , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/prevención & control , Anciano , Procedimientos Quirúrgicos Cardíacos/estadística & datos numéricos , Femenino , Depuradores de Radicales Libres/administración & dosificación , Depuradores de Radicales Libres/uso terapéutico , Mortalidad Hospitalaria , Hospitalización/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Ensayos Clínicos Controlados Aleatorios como Asunto , Fármacos Renales , Factores de Riesgo , Tasa de Supervivencia , Insuficiencia del Tratamiento , Resultado del Tratamiento
12.
Europace ; 17(12): 1834-9, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25911349

RESUMEN

AIMS: Postoperative atrial fibrillation (POAF), new-onset AF after open heart surgery (OHS), is thought to be related to pericarditis. Based on AF studies in the canine sterile pericarditis model, we hypothesized that POAF in patients after OHS may be associated with a rapid, regular rhythm in the left atrium (LA), suggestive of an LA driver maintaining AF. The aim of this study was to test the hypothesis that in patients with POAF, atrial electrograms (AEGs) recorded from at least one of the two carefully selected LA sites would manifest a rapid, regular rhythm with AEGs of short cycle length (CL) and constant morphology, but a selected right atrial (RA) site would manifest AEGs with irregular CLs and variable morphology. METHODS AND RESULTS: In 44 patients undergoing OHS, AEGs recorded from the epicardial surface of the RA, the LA portion of Bachmann's bundle, and the posterior LA during sustained AF were analysed for regularity of CL and morphology. Sustained AF occurred in 15 of 44 patients. Atrial electrograms were recorded in 11 of 15 patients; 8 of 11 had rapid, regular activation with constant morphology recorded from at least one LA site; no regular AEG sites were present in 3 of 11 patients. CONCLUSIONS: Atrial electrograms recorded during sustained POAF frequently demonstrated rapid, regular activation in at least one LA site, consistent with a driver maintaining AF.


Asunto(s)
Fibrilación Atrial/etiología , Aleteo Atrial/etiología , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Potenciales de Acción , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Aleteo Atrial/diagnóstico , Aleteo Atrial/fisiopatología , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Humanos , Factores de Tiempo , Resultado del Tratamiento
13.
J Card Surg ; 30(2): 125-34, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25533177

RESUMEN

BACKGROUND: Minimally invasive aortic valve replacement (mAVR) is increasingly preferred over conventional AVR (cAVR). However, data comparing these procedures present conflicting results. Hence, we conducted a systematic review and meta-analysis comparing clinical results in these cohorts. METHOD: Only randomized controlled trials (RCT) and propensity-matched observational studies (POS) (1998-2013) comparing clinical outcome of patients subjected to mAVR or cAVR were pooled. Continuous data was compared using mean/standardized mean difference (MD/SMD) while categorical results were pooled to obtain an odds ratio (OR) with a 95% confidence interval. RESULTS: A total of 18 studies (6 RCT and 12 POS) (1973 mAVR patients; 2697 cAVR patients) were analyzed. The mean ischemic time was significantly longer with mAVR (MD 9.42 minutes [4.25-14.59]; p < 0.01). However, early mortality (mAVR [1.8%] and cAVR [3%]) was comparable (OR 0.70 [0.46-1.06]; p = 0.09). Postoperative ventilation time was slightly shorter after mAVR (7.5 vs 11.1 hours; p = 0.07), and hospital discharge was earlier after mAVR (MD -1.05 [-1.64 to -0.46]; p < 0.01). However, mAVR failed to reduce transfusion requirement (OR 0.77 [0.51-1.14]; p = 0.19) or pain scores (SMD -0.25 [-0.65 to 0.13]; p = 0.20). Postoperative atrial fibrillation (p = 0.67) and stroke (p = 0.79) rates were comparable. Pooled rate of conversion to full sternotomy was 2.5%. Cosmetic satisfaction could not be pooled due to reporting heterogeneity. CONCLUSION: Minimally invasive aortic valve replacement can be performed safely despite the longer ischemic time. While minimally invasive surgery does demonstrate some advantages in postoperative recovery, we failed to find any other substantial improvement in outcome over conventional aortic valve replacement.


Asunto(s)
Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Anciano , Estudios de Cohortes , Bases de Datos Bibliográficas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Puntaje de Propensión , Ensayos Clínicos Controlados Aleatorios como Asunto
14.
J Card Surg ; 30(7): 547-54, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25989324

RESUMEN

INTRODUCTION: Levosimendan is implemented in patients with low cardiac output after cardiac surgery. However, the strength of evidence is limited by randomized controlled trials enrolling a small number of patients. Hence we have conducted a systematic review to determine the role of levosimendan in adult cardiac surgery. METHODS: PUBMED, WoS, Cochrane database, and SCOPUS were systematically queried to identify original English language peer-reviewed literature (inception-October 2014) comparing clinical results of adult cardiac surgery between levosimendan and control. Pooled odds ratio (OR) was calculated using the Peto method; p < 0.05 is significant; results are presented within 95% confidence intervals. Continuous data was compared using standardized mean difference/mean difference. RESULTS: Fourteen studies were included in the analysis. Levosimendan reduced early mortality in patients with reduced ejection fraction (5.5% vs. 9.1%) (OR 0.48 [0.23-0.76]; p = 0.004). This result was confirmed using sensitivity analysis. Postoperative acute renal failure was lower with levosimendan therapy (7.4% vs. 11.5%). Intensive care unit stay was shorter in the levosimendan cohort comparable in both groups (standardized mean difference -0.31 [-0.53, -0.09]; p = 0.006; I(2) = 33.6%). Levosimendan-treated patients stayed 1.01 (1.61-0.42) days shorter when compared to control (p = 0.001). CONCLUSION: Our meta-analysis demonstrates that Levosimendan improves clinical outcomes in patients with left ventricular dysfunction undergoing cardiac surgery. Results of the ongoing multicenter randomized controlled trial are awaited to provide more conclusive evidence regarding the benefit of this drug.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Cardiotónicos/uso terapéutico , Hidrazonas/uso terapéutico , Complicaciones Posoperatorias/tratamiento farmacológico , Complicaciones Posoperatorias/mortalidad , Piridazinas/uso terapéutico , Disfunción Ventricular Izquierda/tratamiento farmacológico , Disfunción Ventricular Izquierda/mortalidad , Lesión Renal Aguda/prevención & control , Adulto , Gasto Cardíaco Bajo/tratamiento farmacológico , Gasto Cardíaco Bajo/mortalidad , Gasto Cardíaco Bajo/prevención & control , Bases de Datos Bibliográficas , Humanos , Complicaciones Posoperatorias/prevención & control , Ensayos Clínicos Controlados Aleatorios como Asunto , Simendán , Disfunción Ventricular Izquierda/prevención & control
15.
J Card Surg ; 28(6): 693-4, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23930737

RESUMEN

We present a rare complication of sternotomy wire removal in a patient with history of coronary artery bypass graft four years prior now undergoing redo sternotomy for aortic valve replacement. Upon removal of the third sternotomy wire the patient experienced hemoptysis from intrapulmonary hemorrhage, requiring that the procedure be aborted; careful review of preoperative computed tomography (CT) demonstrated this sternotomy wire to be traversing through lung parenchyma.


Asunto(s)
Hemoptisis/etiología , Hemorragia/complicaciones , Fijadores Internos/efectos adversos , Complicaciones Intraoperatorias/etiología , Enfermedades Pulmonares/complicaciones , Esternotomía/efectos adversos , Esternotomía/métodos , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Puente de Arteria Coronaria , Implantación de Prótesis de Válvulas Cardíacas , Hemorragia/diagnóstico por imagen , Humanos , Enfermedades Pulmonares/diagnóstico por imagen , Masculino , Periodo Preoperatorio , Reoperación , Tomografía Computarizada por Rayos X
16.
Ann Thorac Surg ; 115(1): 72-78, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35283098

RESUMEN

BACKGROUND: We investigated outcomes of coronary artery bypass grafting (CABG) with endoscopic vein harvest (EVH) vs open vein harvest (OVH) within the Evaluation of XIENCE Versus CABG (EXCEL) trial. METHODS: All patients in EXCEL randomized to CABG were included in this study. For this analysis, the primary end points were ischemia-driven revascularization (IDR) and graft stenosis or occlusion at 5 years. Additional end points were as follows: a composite of death from any cause, stroke, or myocardial infarction; bleeding; blood product transfusion; major arrhythmia; and infection requiring antibiotics. Event rates were based on Kaplan-Meier estimates in time-to-first-event analyses. RESULTS: Of the 957 patients randomized to CABG, 686 (71.7%) received at least 1 venous graft with 257 (37.5%) patients in the EVH group and 429 (62.5%) patients in the OVH group. At 5 years, IDR was higher (11.5% vs 6.7%; P = .047) in the EVH group. At 5 years, rates of graft stenosis or occlusion (9.7% vs 5.4%; P = .054) and the primary end point (17.4% vs 20.9%; P = .27) were similar. In-hospital bleeding (11.3% vs 13.8%; P = .35), in-hospital blood product transfusion (12.8% vs 13.1%; P = .94), and infection requiring antibiotics within 1 month (13.6% vs 16.8%; P = .27) were similar between EVH and OVH patients. Major arrhythmia in the hospital (19.8% vs 13.5%; P = .03) and within 1 month (21.8% vs 15.4%; P = .03) was higher in EVH patients. CONCLUSIONS: IDR at 5 years was higher in the EVH group. EVH and OVH patients had similar rates of graft stenosis or occlusion and the composite of death, stroke, or myocardial infarction at 5 years.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Accidente Cerebrovascular , Humanos , Enfermedad de la Arteria Coronaria/cirugía , Constricción Patológica , Vena Safena/trasplante , Endoscopía , Resultado del Tratamiento
17.
Open Heart ; 10(1)2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37173100

RESUMEN

OBJECTIVE: To evaluate whether transcatheter or surgical aortic valve replacement (TAVR or SAVR) affects clinical and haemodynamic outcomes in symptomatic patients with moderately-severe aortic stenosis (AS). METHODS: Echocardiographic evidence of severe AS for enrolment in the Evolut Low Risk trial was based on site-reported measurements. For this post hoc analysis, core laboratory measurements identified patients with symptomatic moderately-severe AS (1.0

Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Calidad de Vida , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Resultado del Tratamiento
18.
Ann Thorac Surg ; 115(4): 929-938, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36610532

RESUMEN

BACKGROUND: Current guidelines recommend a target international normalized ratio (INR) range of 2.5 to 3.5 in patients with a mechanical mitral prosthesis. The Prospective Randomized On-X Anticoagulation Clinical Trial (PROACT) Mitral randomized controlled noninferiority trial assessed safety and efficacy of warfarin at doses lower than currently recommended in patients with an On-X (Artivion, Inc) mechanical mitral valve. METHODS: After On-X mechanical mitral valve replacement, followed by at least 3 months of standard anticoagulation, 401 patients at 44 North American centers were randomized to low-dose warfarin (target INR, 2.0-2.5) or standard-dose warfarin (target INR, 2.5-3.5). All patients were prescribed aspirin, 81 mg daily, and encouraged to use home INR testing. The primary end point was the sum of the linearized rates of thromboembolism, valve thrombosis, and bleeding events. The design was based on an expected 7.3% event rate and 1.5% noninferiority margin. RESULTS: Mean patient follow-up was 4.1 years. Mean INR was 2.47 and 2.92 (P <.001) in the low-dose and standard-dose warfarin groups, respectively. Primary end point rates were 11.9% per patient-year in the low-dose group and 12.0% per patient-year in the standard-dose group (difference, -0.07%; 95% CI, -3.40% to 3.26%). The CI >1.5%, thus noninferiority was not achieved. Rates (percentage per patient-year) of the individual components of the primary end point were 2.3% vs 2.5% for thromboembolism, 0.5% vs 0.5% for valve thrombosis, and 9.13% vs 9.04% for bleeding. CONCLUSIONS: Compared with standard-dose warfarin, low-dose warfarin did not achieve noninferiority for the composite primary end point. (PROACT Clinicaltrials.gov number, NCT00291525).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Tromboembolia , Trombosis , Humanos , Warfarina/efectos adversos , Anticoagulantes/efectos adversos , Estudios Prospectivos , Válvula Mitral/cirugía , Tromboembolia/etiología , Tromboembolia/prevención & control , Hemorragia/etiología , Trombosis/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
19.
Cardiovasc Revasc Med ; 42: 1-5, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35398007

RESUMEN

BACKGROUND: Death in high- and intermediate-risk patients after self-expanding transcatheter (TAVR) and surgical aortic valve replacement (surgery) differed in mechanisms and timing. In both risk groups, 1-year all-cause mortality was lower in TAVR than in surgery patients. The differences in mechanism and timing of death in low-risk patients has not been studied. This report explores the mechanisms of death during 3 time periods; 0 to 30 days (early), 31 to 120 days (recovery), and 121 to 365 days (late). METHODS: We retrospectively examined the mechanisms and timing of death following TAVR or surgery in the randomized Evolut Low Risk Trial. Patients were enrolled between March 2016 and November 2018 from 86 designated TAVR centers. Mechanisms of death were categorized as due to technical reasons, failure to repair, complications linked to death, failure to recover or other. RESULTS: All-cause mortality at 1 year was 2.2% for TAVR and 2.8% for surgery, p = 0.44. Early deaths included 3 TAVR patients, all due to technical reasons, and 8 surgery patients (1 technical, 5 complications and 2 failed to recover). Recovery period deaths included 6 TAVR patients (4 complications, 1 failed to recover and 1 other), and 1 surgery patient from complications of valve endocarditis. Late period deaths included 6 TAVR patients and 9 surgery patients, primarily due to complications. CONCLUSIONS: In this low-risk study cohort, no patient died from failure to repair the valve; reduction in procedural complications in the TAVR and surgery groups remain opportunities for further improvement in outcomes. Clinical Trial Registrations (clinicaltrials.gov): NCT02701283 (Evolut Low Risk).


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
20.
Ann Thorac Surg ; 2022 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-35101419

RESUMEN

This article has been withdrawn at the request of the author(s) and/or editor. The Publisher apologizes for any inconvenience this may cause. The full Elsevier Policy on Article Withdrawal can be found at https://www.elsevier.com/about/our-business/policies/article-withdrawal.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA