Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
BMC Musculoskelet Disord ; 15: 194, 2014 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-24894637

RESUMEN

BACKGROUND: Loss of reduction and screw perforation causes high failure rates in the treatment of proximal humerus fractures. The purpose of the present study was to evaluate the early postoperative complications using modern Dynamic Locking Screws (DLS 3.7) for plating of proximal humerus fractures. METHODS: Between 03/2009 and 12/2010, 64 patients with acute proximal humerus fractures were treated by angular stable plate fixation using DLSs in a limited multi-centre study. Follow-up examinations were performed three, six, twelve and twenty-four weeks postoperatively and any complications were carefully collected. RESULTS: 56 of 64 patients were examined at the six-month follow-up. Complications were observed in 12 patients (22%). In five cases (9%), a perforation of the DLS 3.7 occurred. CONCLUSIONS: Despite the use of modern DLS 3.7, the early complications after plating of proximal humerus fractures remain high. The potential advantage of the DLS 3.7 regarding secondary screw perforation has to be confirmed by future randomized controlled trials.


Asunto(s)
Tornillos Óseos/efectos adversos , Fijación Interna de Fracturas/instrumentación , Complicaciones Posoperatorias/etiología , Fracturas del Hombro/cirugía , Anciano , Placas Óseas , Diseño de Equipo , Femenino , Estudios de Seguimiento , Curación de Fractura , Humanos , Masculino , Persona de Mediana Edad , Osteonecrosis/etiología , Centros Traumatológicos
2.
Knee Surg Sports Traumatol Arthrosc ; 22(2): 448-55, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23370985

RESUMEN

PURPOSE: Operative treatment for middle-third clavicle fractures has been increasing as recent data has demonstrated growing patient dissatisfaction and functional deficits after non-operative management. A controlled biomechanical comparison of the characteristics of locked intramedullary (IM) fixation versus superior pre-contoured plating for fracture repair and hardware removal is warranted. Therefore, the purpose of the present study was to investigate potential differences between these devices in a biomechanical model. METHODS: Thirty fourth-generation composite clavicles were randomized to one of five groups with 6 specimens each and tested in a random order. The groups tested were intact, repair with plate, repair with IM device, plate removal, and IM device removal. The lateral end of the clavicles was loaded to failure at a rate of 60 mm/min in a cantilever bending setup. Failure mechanism, energy (J), and torque (Nm) at the site of failure were recorded. RESULTS: Failure torque of the intact clavicle (mean ± standard deviation) was 36.5 ± 7.3 Nm. Failure torques of the IM repair (21.5 ± 9.0 Nm) and plate repair (18.2 ± 1.6 Nm) were not significantly different (n.s.) but were significantly less than the intact group (P < 0.05). Failure torque following IM device removal (30.2 ± 6.5 Nm) was significantly greater than plate removal (12.9 ± 2.0 Nm) (P < 0.05). No significant differences were observed between the intact and IM device removal groups (n.s.). CONCLUSION: The results of the current study demonstrate that IM and plate devices provide similar repair strength for middle-third clavicle fractures. However, testing of the hardware removal groups found the IM device removal group to be significantly stronger than the plate removal group.


Asunto(s)
Placas Óseas , Tornillos Óseos , Clavícula/lesiones , Fijación Interna de Fracturas/instrumentación , Fracturas Óseas/cirugía , Fijadores Internos , Fenómenos Biomecánicos , Clavícula/cirugía , Remoción de Dispositivos , Fijación Interna de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Humanos , Torque
3.
Acta Orthop ; 76(2): 241-4, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16097551

RESUMEN

INTRODUCTION: Os acromiale is a rare anatomical condition; its incidence in cadaver studies has been found to be approximately 8%. In this retrospective study we investigated the incidence and types of os acromiale in patients with rotator cuff tears. METHODS: We assessed operation notes and axillary radiographs for the presence and the type of os acromiale in 1000 consecutive patients with open rotator cuff repairs. RESULTS: 62 patients (6.2%) showed an os acromiale in the axillary radiographs. In 6 of these the os acromiale was not described in the operation notes. 57 os meso-acromiale and 5 os pre-acromiale were found. The average number of tendons involved in the cuff tear was the same (1.4) in patients with and without os acromiale. The average age of patients with os acromiale was 55 years, and 56 years in patients without os acromiale. INTERPRETATION: Os acromiale is a co-condition in patients with rotator cuff tear. The prevalence of os acromiale in patients with rotator cuff tear is similar to that in a standard population with unknown integrity status of the rotator cuff. Thus, it seems debatable whether an os acromiale is a pathological condition leading to rotator cuff tears.


Asunto(s)
Acromion/patología , Lesiones del Manguito de los Rotadores , Acromion/anomalías , Acromion/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Estudios Retrospectivos , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA