Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Radiologia (Engl Ed) ; 66(2): 107-113, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38614527

RESUMEN

INTRODUCTION AND OBJECTIVES: To compare gonad doses with and without a gonad protector and to optimize the use of gonadal protectors in infants thorax radiography. MATERIALS AND METHODS: Two pediatric anthropomorphic phantoms are used: an X-ray system for KXO-50SS/DRX-3724HD, and a digital radiography system for CALNEO Smart C12, with and without a gonad protector during infants thorax radiography. A real time skin dosimeter is placed on the X-ray system, and a real time skin dosimeter is inserted on the front side of the mammary gland, the front and back sides of the true pelvis level, and on the ovaries and testes. The X-ray system is irradiated 15 times using phantoms with and without a gonad protector. The measured entrance patient doses values of for the real time skin dosimeter are compared for each phantom, with and without the gonad protector. RESULTS: The medium of measured entrance patient doses values for front side dose of the true pelvis level with and without the protector are 10.00 and 5.00 µGy at newborn, and 10.00 and 0.00µGy at one year, respectively. The medium of measured entrance patient doses values for the back side dose of the true pelvis level with and without the protector are 0.00 and 0.00 µGy at both newborn one year, respectively. The measured entrance patient doses cannot be detected in the ovaries and testes with or without the protector. No significant differences are observed in the measured entrance patient doses values for the front and back side doses of the pelvis, ovaries, and testes at newborn and one year, with and without the protector (p>0.05). CONCLUSIONS: No significant difference was observed in gonad dose measurements with and without the gonad protector during infants chest radiography. We believe that gonadal protector wearing is not necessary.


Asunto(s)
Gónadas , Lactante , Recién Nacido , Humanos , Niño , Radiografía
2.
Radiography (Lond) ; 30(1): 382-387, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38150883

RESUMEN

INTRODUCTION: To compare CT (computed tomography) values for enhancement of the abdominal aorta and liver parenchyma during dynamic contrast enhancement (CE) CT in cirrhotic patients with and without splenomegaly (SM). METHODS: We considered 258 patients (83 males and 46 females for the splenomegaly group, and 83 males and 46 females for the control group) for this retrospective study. We measured CT values in the abdominal aorta and hepatic parenchyma during the hepatic arterial (HAP) and portal venous (PVP) phases. The aortic CE at HAP and the hepatic parenchymal CE at PVP were compared between the two groups. For success rate of scans, we also calculated the optimal CE rates (>280 HU in the abdominal aorta and >50 HU in the hepatic parenchyma) for each group. RESULTS: In the SM group, the CE for abdominal aorta was decreased during the aortic phase for a dynamic CE-CT (p < 0.05). When evaluating the success rates, they were found to be 65.1 % and 58.9 % in the SM group and 81.4 % and 72.3 % in the non-SM group (p < 0.05). CONCLUSION: The success rate of scans and CE for the abdominal aorta during the aortic phase exhibited a significant decrease during dynamic CE-CT scans on patients with SM. Patients with SM may have reduced diagnostic ability with typical contrast injection protocols. IMPLICATIONS FOR PRACTICE: It may be necessary to change the injection rates and contrast medium volume during CE-CT depending on the presence or absence of SM.


Asunto(s)
Medios de Contraste , Esplenomegalia , Masculino , Femenino , Humanos , Estudios Retrospectivos , Esplenomegalia/diagnóstico por imagen , Cirrosis Hepática/complicaciones , Cirrosis Hepática/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
3.
Radiography (Lond) ; 30(1): 408-415, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38176131

RESUMEN

INTRODUCTION: This study aimed to compare the vascular enhancement and radiation dose in preoperative transcatheter aortic valve implantation (TAVI) computed tomography (CT) with a reduced contrast medium (CM) using volume scans in 256-multidetector row CT (MDCT) with a standard CM using 64-MDCT. METHODS: This study included 78 patients with preoperative TAVI CT with either 64- or 256-MDCT. The CM was injected at 1.5 mL/kg in the 64-MDCT group and 1.0 mL/kg in the 256-MDCT group. We compared vascular enhancement of the aortic root and access routes, image quality (IQ) scores, and radiation dose in both groups. RESULTS: Despite the reduced CM (by 33 %) in the 256-MDCT group, the mean vascular enhancement of the right and left subclavian arteries was significantly higher than that in the 64-MDCT group [284 and 267 Hounsfield units (HU) vs. 376 and 359 HU; p < 0.05]; however, no significant differences in the mean vascular enhancement in the ascending aorta, abdominal aorta at the celiac level, and bilateral common femoral arteries were observed between the two groups (p > 0.05 for all). The median IQ scores at the aortic root were higher in the 256-MDCT group than in the 64-MDCT group (3 vs. 4; p < 0.05), and those at the femoral access routes were comparable (4 vs. 4; p = 0.33). The mean effective dose was significantly reduced by 30 % in the 256-MDCT group (23.6 vs. 16.3 mSv; p < 0.05). CONCLUSION: In preoperative TAVI CT, volume scans using 256-MDCT provide comparable or better vascular enhancement and IQ with a 30 % reduction in CM and radiation dose than those using 64-MDCT. IMPLICATIONS FOR PRACTICE: Volume scan using 256-MDCT for preoperative TAVI CT may reduce CM and radiation dose in TAVI patients with renal dysfunction.


Asunto(s)
Estenosis de la Válvula Aórtica , Yodo , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Tomografía Computarizada Multidetector , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Dosis de Radiación , Aorta Abdominal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA