Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38940255

RESUMEN

INTRODUCTION: Gliflozins are recommended as first-line treatment in patients with heart failure and/or cardiovascular comorbidities and are demonstrated to reduce atrial fibrillation (AF) occurrence. However, it is not well known which gliflozin yields the larger cardioprotection in terms of AF occurrence reduction. Hence, we aimed to compare data regarding AF recurrence associated with different gliflozins. METHODS: An accurate search of online scientific libraries (from inception to June 1, 2023) was performed. Fifty-nine studies were included in the meta-analysis involving 108 026 patients, of whom 60 097 received gliflozins and 47 929 received placebo. RESULTS: Gliflozins provided a statistically significant reduction of AF occurrence relative to standard of care therapy in the overall population (relative risks [RR]: 0.8880, 95% CI: [0.8059; 0.9784], p = .0164) and in patients with diabetes and cardiorenal diseases (RR: 0.8352, 95% CI: [0.7219; 0.9663], p = .0155). Dapagliflozin significantly decreased AF occurrence as compared to placebo (0.7259 [0.6337; 0.8316], p < .0001) in the overall population, in patients with diabetes (RR: 0.2482, 95% CI: [0.0682; 0.9033], p = .0345), with diabetes associated with cardiorenal diseases (RR: 0.7192, 95% CI: [0.5679; 0.9110], p = .0063) and in the subanalysis including studies with follow-up ≥1 year (RR: 0.7792, 95% CI: [0.6508; 0.9330], p = .0066). No significant differences in terms of AF protection were found among different gliflozins. CONCLUSIONS: Dapagliflozin use was associated with significant reduction in AF risk as compared to placebo in overall population and patients with diabetes, whereas the use of other gliflozins did not significantly reduce AF occurrence.

2.
J Cardiovasc Electrophysiol ; 35(3): 379-388, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38185855

RESUMEN

BACKGROUND: The mechanism of typical slow-fast atrioventricular nodal re-entrant tachycardia (AVNRT) and its anatomical and electrophysiological circuit inside the right atrium (RA) and Koch's Triangle (KT) are not well known. OBJECTIVE: To identify the potentials of the compact AV node and inferior extensions and to perform accurate mapping of the RA and KT in sinus rhythm (SR) and during AVNRT, to define the tachycardia circuit. METHODS: Consecutive patients with typical AVNRT were enrolled in 12 Italian centers and underwent mapping and ablation by means of a basket catheter with small electrode spacing for ultrahigh-density mapping and a modified signal-filtering toolset to record the potentials of the AV nodal structures. RESULTS: Forty-five consecutive cases of successful ablation of typical slow-fast AVNRT were included. The mean SR cycle length (CL) was 784.1 ± 6 ms and the mean tachycardia CL was 361.2 ± 54 ms. The AV node potential had a significantly shorter duration and higher amplitude in sinus rhythm than during tachycardia (60 ± 40 ms vs. 160 ± 40 ms, p < .001 and 0.3 ± 0.2 mV vs. 0.09 ± 0.12 mV, p < .001, respectively). The nodal potential duration extension was 169.4 ± 31 ms, resulting in a time-window coverage of 47.6 ± 9%. The recording of AV nodal structure potentials enabled us to obtain 100% coverage of the tachycardia CL during slow-fast AVNRT. CONCLUSION: Detailed recording of the potentials of nodal structures is possible by means of multipolar catheters for ultrahigh-density mapping, allowing 100% of the AVNRT CL to be covered. These results also have clinical implications for the ablation of right-septal and para-septal arrhythmias.


Asunto(s)
Ablación por Catéter , Taquicardia por Reentrada en el Nodo Atrioventricular , Humanos , Nodo Atrioventricular/cirugía , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Ablación por Catéter/métodos , Atrios Cardíacos , Electrodos
3.
Front Cardiovasc Med ; 11: 1420916, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39175628

RESUMEN

Background: Typical isthmus-dependent atrial flutter (AFL) is traditionally treated through radiofrequency (RF) ablation to create a bidirectional conduction block across the cavo-tricuspid isthmus (CTI) in the right atrium. While this approach is successful in many cases, certain anatomical variations can present challenges, making CTI ablation difficult. Methods: We enrolled four patients with typical counter-clockwise AFL who displayed an epicardial bridge at the CTI. Patients underwent high-resolution mapping of the right atrium and CTI ablation. Results: Post-mapping identified areas of early focal activation outside the lesion line which suggested the presence of an epi-endocardial bridge with an endocardial breakthrough, confirmed by recording a unipolar rS pattern on electrograms at that site. A stable CTI block was achieved in all patients only after ablation at the site of the epi-endocardial breakthrough. Conclusions: The presence of an epicardial bridge at the CTI, allowing conduction to persist despite endocardial ablation, should be considered in challenging cases of CTI-dependent AFL. Understanding this phenomenon and utilizing appropriate mapping and ablation techniques are essential for achieving successful and lasting CTI block.

4.
J Clin Med ; 13(9)2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38731236

RESUMEN

The implantation of cardiac electronic devices (CIEDs), including pacemakers and defibrillators, has become increasingly prevalent in recent years and has been accompanied by a significant rise in cardiac device infections (CDIs), which pose a substantial clinical and economic burden. CDIs are associated with hospitalizations and prolonged antibiotic therapy and often necessitate device removal, leading to increased morbidity, mortality, and healthcare costs worldwide. Approximately 1-2% of CIED implants are associated with infections, making this a critical issue to address. In this contemporary review, we discuss the burden of CDIs with their risk factors, healthcare costs, prevention strategies, and clinical management.

5.
J Clin Med ; 13(6)2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38541971

RESUMEN

Ventricular tachycardias (VTs) and electrical storms (ES) are life-threatening conditions mostly seen in the setting of structural heart disease (SHD). Traditional management strategies, predominantly centered around pharmacological interventions with antiarrhythmic drugs, have demonstrated limited efficacy in these cases, whereas catheter ablation is related with more favorable outcomes. However, patients with hemodynamically unstable, recurrent VT or ES may present cardiogenic shock (CS) that precludes the procedure, and catheter ablation in patients with SHD portends a multifactorial intrinsic risk of acute hemodynamic decompensation (AHD), that is associated with increased mortality. In this setting, the use of mechanical circulatory support (MCS) systems allow the maintenance of end-organ perfusion and cardiac output, improving coronary flow and myocardial mechanics, and minimizing the effect of cardiac stunning after multiple VT inductions or cardioversion. Although ablation success and VT recurrence are not influenced by hemodynamic support devices, MCS promotes diuresis and reduces the incidence of post-procedural kidney injury. In addition, MCS has a role in post-procedural mortality reduction at long-term follow-up. The current review aims to provide a deep overview of the rationale and modality of MCS in patients with refractory arrhythmias and/or undergoing VT catheter ablation, underlining the importance of patient selection and timing for MCS and summarizing reported clinical experiences in this field.

6.
Int J Cardiol ; 401: 131682, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38176657

RESUMEN

BACKGROUND: Gender-related discrepancies in personal and professional life have been reported among radio-exposed workers. We assessed this topic among cardiac catheterization workers in Italy, with a focus on gender and working position. METHODS: Radio-exposed workers affiliated with the Italian Association of Hospital Cardiologists were invited to answer an online survey, which included 41 questions formatted as multiple choice. RESULTS: Overall, 237 workers responded. The proportion of males was significantly higher than that of females in the population aged >50 years. A greater portion of females than males perceived female-gender discrimination regarding career advancement (77.2% vs 30.9%, p < 0.001) and work compensation (49.1% vs. 17.1%, p < 0.001). There was no difference in perceived gender- discrimination in terms of career advancement opportunities between physician and non-physicians. A larger portion of females than males experienced workplace discrimination (51.8% of females vs. 8.1% of males, p < 0.0001). Non-physician responders made up 38.8% of all respondents and reported a lower yearly radiation exposure than physicians. Non-physicians were more aware of the laws regulating lab access during pregnancy than physicians (93.5% vs. 48.3%, p < 0.0001). A greater percentage of female nurses than physicians communicate without hesitation the pregnancy status to their employers (45.6% vs 20%, p < 0.001). CONCLUSIONS: Gender-based career disparities were perceived among physicians and non-physician staff of cardiology interventional laboratories. Strategies should be implemented to ensure gender equality in career opportunities and to increase knowledge of radioprotection and the laws regulating access to laboratories during pregnancy.


Asunto(s)
Cardiólogos , Cardiología , Médicos , Exposición a la Radiación , Masculino , Humanos , Femenino , Embarazo , Laboratorios , Encuestas y Cuestionarios
7.
Int J Cardiol ; 412: 132330, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38964558

RESUMEN

BACKGROUND: Using three-dimensional (3D) modalities for optimal pre-procedure planning in transcatheter aortic valve replacement (TAVR) is critical for procedural success. However, current methods rely on visualizing images on a two-dimensional screen, using shading and colors to create the illusion of 3D, potentially impeding the accurate comprehension of the actual anatomy structures. In contrast, a new Mixed Reality (MxR) based software enables accurate 3D visualization, imaging manipulation, and quantification of measurements. AIMS: The study aims to evaluate the feasibility, reproducibility, and accuracy of dimensions of the aortic valve complex as measured with a new holographic MxR software (ARTICOR®, Artiness srl, Milano, Italy) compared to a widely used software for pre-operative sizing and planning (3mensio Medical Imaging BV, Bilthoven, The Netherlands). METHODS: This retrospective, observational, double-center study enrolled 100 patients with severe aortic stenosis who underwent cardiac computed tomography (CCT) before TAVR. The CCT datasets of volumetric aortic valve images were analyzed using 3Mensio and newly introduced MxR-based software. RESULTS: Ninety-eight percent of the CCT datasets were successfully converted into holographic models. A higher level of agreement between the two software systems was observed for linear metrics (short, long, and average diameter). In comparison, agreement was lower for area, perimeter, and annulus-to-coronary ostia distance measurements. Notably, the annulus area, annular perimeter, left ventricular outflow tract (LVOT) area, and LVOT perimeter were significantly and consistently smaller with the MxR-based software compared to the 3Mensio. Excellent interobserver reliability was demonstrated for most measurements, especially for direct linear measurements. CONCLUSIONS: Linear measurements of the aortic valve complex using MxR-based software are reproducible compared to the standard CCT dataset analyzed with 3Mensio. MxR-based software could represent an accurate tool for the pre-procedural planning of TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Holografía , Reemplazo de la Válvula Aórtica Transcatéter , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Humanos , Estudios Retrospectivos , Holografía/métodos , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Masculino , Anciano de 80 o más Años , Anciano , Imagenología Tridimensional/métodos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Reproducibilidad de los Resultados , Realidad Aumentada , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA