Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Ultraschall Med ; 42(2): 178-186, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32663881

RESUMEN

BACKGROUND: This prospective multicenter study funded by the DEGUM assesses the diagnostic accuracy of standardized contrast-enhanced ultrasound (CEUS) for the noninvasive diagnosis of hepatocellular carcinoma (HCC) in high-risk patients. METHODS: Patients at high risk for HCC with a histologically proven focal liver lesion on B-mode ultrasound were recruited prospectively in a multicenter approach. Clinical and imaging data were entered via online entry forms. The diagnostic accuracies for the noninvasive diagnosis of HCC were compared for the conventional interpretation of standardized CEUS at the time of the examination (= CEUS on-site) and the two CEUS algorithms ESCULAP (Erlanger Synopsis for Contrast-enhanced Ultrasound for Liver lesion Assessment in Patients at risk) and CEUS LI-RADS (Contrast-Enhanced UltraSound Liver Imaging Reporting and Data System). RESULTS: 321 patients were recruited in 43 centers; 299 (93.1 %) had liver cirrhosis. The diagnosis according to histology was HCC in 256 cases, and intrahepatic cholangiocarcinoma (iCCA) in 23 cases. In the subgroup of cirrhotic patients (n = 299), the highest sensitivity for the diagnosis of HCC was achieved with the CEUS algorithm ESCULAP (94.2 %) and CEUS on-site (90.9 %). The lowest sensitivity was reached with the CEUS LI-RADS algorithm (64 %; p < 0.001). However, the specificity of CEUS LI-RADS (78.9 %) was superior to that of ESCULAP (50.9 %) and CEUS on-site (64.9 %; p < 0.001). At the same time, the negative predictive value (NPV) of CEUS LI-RADS was significantly inferior to that of ESCULAP (34.1 % vs. 67.4 %; p < 0.001) and CEUS on-site (62.7 %; p < 0.001). The positive predictive values of all modalities were high (around 90 %), with the best results seen for CEUS LI-RADS and CEUS on-site. CONCLUSION: This is the first multicenter, prospective comparison of standardized CEUS and the recently developed CEUS-based algorithms in histologically proven liver lesions in cirrhotic patients. Our results reaffirm the excellent diagnostic accuracy of CEUS for the noninvasive diagnosis of HCC in high-risk patients. However, on-site diagnosis by an experienced examiner achieves an almost equal diagnostic accuracy compared to CEUS-based diagnostic algorithms.


Asunto(s)
Neoplasias de los Conductos Biliares , Carcinoma Hepatocelular , Neoplasias Hepáticas , Algoritmos , Carcinoma Hepatocelular/diagnóstico por imagen , Medios de Contraste , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Estudios Prospectivos , Ultrasonografía
2.
Ultraschall Med ; 40(2): 132-162, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30991429

RESUMEN

Ultrasound should be the first-line imaging method in the medical care of patients with inflammatory bowel disease. It can be used to differentiate between Crohn's disease and ulcerative colitis and to detect numerous complications like stenoses, fistulas, and abscesses. As the method is also highly suitable for follow-up, stressful endoscopic procedures and examinations involving radiation are less necessary. Comparison studies with MRI and CT show that ultrasound is not an inferior method and it is therefore included in all guidelines. Intensifying physician training in this method will help to ensure its comprehensive use.


Asunto(s)
Colitis Ulcerosa , Enfermedad de Crohn , Enfermedades Inflamatorias del Intestino , Colitis Ulcerosa/diagnóstico por imagen , Enfermedad de Crohn/diagnóstico por imagen , Humanos , Enfermedades Inflamatorias del Intestino/diagnóstico por imagen , Imagen por Resonancia Magnética , Ultrasonografía
4.
Ultrasound Med Biol ; 47(11): 3170-3180, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34417066

RESUMEN

The hallmark for the non-invasive diagnosis of hepatocellular carcinoma (HCC) with contrast-enhanced ultrasound (CEUS) in cirrhosis is arterial phase hyperenhancement (APHE), followed by late-onset (>60 s), mild washout. Large retrospective studies report this pattern of washout to occur in the vast majority of HCCs. However, a prospective multicenter validation of these findings is still missing. Thus, we initiated a prospective multicenter validation study assessing CEUS enhancement patterns in focal liver lesions of patients at risk for HCC. We analyzed lesions that were eventually histology proven in a real-life setting. CEUS patterns were assessed for subgroups of HCC, intrahepatic cholangiocellular carcinoma (iCCA) and non-HCC, non-iCCA lesions. The diagnosis was HCC in 316 lesions (median size: 40 mm), iCCA in 26 lesions (median size: 47.5 mm) and non-HCC, non-iCCA in 53 lesions (median size: 27 mm). Overall, 85.8% of HCCs exhibited APHE. APHE followed by washout occurred in 72.8% of HCCs and 50% of iCCAs and non-HCC, non-iCCA malignancies (p < 0.05). Early and marked washout was associated more commonly with iCCA; HCCs exhibited mostly late and mild washout (onset >4-6 min in 10% of cases). Our prospective data confirm that the typical pattern of APHE followed by late-onset, mild washout occurs in the majority of HCCs.


Asunto(s)
Neoplasias de los Conductos Biliares , Carcinoma Hepatocelular , Neoplasias Hepáticas , Conductos Biliares Intrahepáticos/diagnóstico por imagen , Carcinoma Hepatocelular/diagnóstico por imagen , Medios de Contraste , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Estudios Prospectivos , Estudios Retrospectivos , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA