1.
Int J Mol Sci ; 23(21)2022 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-36362271

RESUMEN

Ultra-high dose rate (UHDR) irradiation regimes have the potential to spare normal tissue while keeping equivalent tumoricidal capacity than conventional dose rate radiotherapy (CONV-RT). This has been called the FLASH effect. In this work, we present a new simulation framework aiming to study the production of radical species in water and biological media under different irradiation patterns. The chemical stage (heterogeneous phase) is based on a nonlinear reaction-diffusion model, implemented in GPU. After the first 1 µs, no further radical diffusion is assumed, and radical evolution may be simulated over long periods of hundreds of seconds. Our approach was first validated against previous results in the literature and then employed to assess the influence of different temporal microstructures of dose deposition in the expected biological damage. The variation of the Normal Tissue Complication Probability (NTCP), assuming the model of Labarbe et al., where the integral of the peroxyl radical concentration over time (AUC-ROO) is taken as surrogate for biological damage, is presented for different intra-pulse dose rate and pulse frequency configurations, relevant in the clinical scenario. These simulations yield that overall, mean dose rate and the dose per pulse are the best predictors of biological effects at UHDR.


Asunto(s)
Dosificación Radioterapéutica , Simulación por Computador
2.
J Appl Clin Med Phys ; 17(3): 262-276, 2016 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-27167283

RESUMEN

Mandatory in several countries, in vivo dosimetry has been recognized as one of the next milestones in radiation oncology. Our department has implemented clinically an EPID based in vivo dosimetry system, EPIgray, by DOSISOFT S.A., since 2006. An analysis of the measurements per linac and energy over a two-year period was performed, which included a more detailed examination per technique and treat-ment site over a six-month period. A comparison of the treatment planning system doses and the doses estimated by EPIgray shows a mean of the differences of 1.9% (± 5.2%) for the two-year period. The 3D conformal treatment plans had a mean dose difference of 2.0% (± 4.9%), while for intensity-modulated radiotherapy and volumetric-modulated arc therapy treatments the mean dose difference was -3.0 (± 5.3%) and -2.5 (± 5.2%), respectively. In addition, root cause analyses were conducted on the in vivo dosimetry measurements of two breast cancer treatment techniques, as well as prostate treatments with intensity-modulated radiotherapy and volumetric-modulated arc therapy. During the breast study, the dose differences of breast treatments in supine position were correlated to patient setup and EPID positioning errors. Based on these observations, an automatic image shift correc-tion algorithm is developed by DOSIsoft S.A. The prostate study revealed that beams and arcs with out-of-tolerance in vivo dosimetry results tend to have more complex modulation and a lower exposure of the points of interest. The statistical studies indicate that in vivo dosimetry with EPIgray has been successfully imple-mented for classical and complex techniques in clinical routine at our institution. The additional breast and prostate studies exhibit the prospects of EPIgray as an easy supplementary quality assurance tool. The validation, the automatization, and the reduction of false-positive results represent an important step toward adaptive radiotherapy with EPIgray.


Asunto(s)
Neoplasias de la Mama/radioterapia , Órganos en Riesgo/efectos de la radiación , Neoplasias de la Próstata/radioterapia , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/instrumentación , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Radiometría/instrumentación , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Semiconductores
3.
Med Phys ; 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38569141

RESUMEN

BACKGROUND: Proton therapy is a form of radiotherapy commonly used to treat various cancers. Due to its high conformality, minor variations in patient anatomy can lead to significant alterations in dose distribution, making adaptation crucial. While cone-beam computed tomography (CBCT) is a well-established technique for adaptive radiation therapy (ART), it cannot be directly used for adaptive proton therapy (APT) treatments because the stopping power ratio (SPR) cannot be estimated from CBCT images. PURPOSE: To address this limitation, Deep Learning methods have been suggested for converting pseudo-CT (pCT) images from CBCT images. In spite of convolutional neural networks (CNNs) have shown consistent improvement in pCT literature, there is still a need for further enhancements to make them suitable for clinical applications. METHODS: The authors introduce the 3D vision transformer (ViT) block, studying its performance at various stages of the proposed architectures. Additionally, they conduct a retrospective analysis of a dataset that includes 259 image pairs from 59 patients who underwent treatment for head and neck cancer. The dataset is partitioned into 80% for training, 10% for validation, and 10% for testing purposes. RESULTS: The SPR maps obtained from the pCT using the proposed method present an absolute relative error of less than 5% from those computed from the planning CT, thus improving the results of CBCT. CONCLUSIONS: We introduce an enhanced ViT3D architecture for pCT image generation from CBCT images, reducing SPR error within clinical margins for APT workflows. The new method minimizes bias compared to CT-based SPR estimation and dose calculation, signaling a promising direction for future research in this field. However, further research is needed to assess the robustness and generalizability across different medical imaging applications.

4.
Phys Med Biol ; 69(4)2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38237181

RESUMEN

We introduce a new calibration method for dual energy CT (DECT) based on material decomposition (MD) maps, specifically iodine and water MD maps. The aim of this method is to provide the first DECT calibration based on MD maps. The experiments were carried out using a general electric (GE) revolution CT scanner with ultra-fast kV switching and used a density phantom by GAMMEX for calibration and evaluation. The calibration process involves several steps. First, we tested the ability of MD values to reproduce Hounsfield unit (HU) values of single energy CT (SECT) acquisitions and it was found that the errors were below 1%, validating their use for HU reproduction. Next, the different definitions of computedZvalues were compared and the robustness of the approach based on the materials' composition was confirmed. Finally, the calibration method was compared with a previous method by Bourqueet al, providing a similar level of accuracy and superior performance in terms of precision. Overall, this novel DECT calibration method offers improved accuracy and reliability in determining tissue-specific physical properties. The resulting maps can be valuable for proton therapy treatments, where precise dose calculations and accurate tissue differentiation are crucial for optimal treatment planning and delivery.


Asunto(s)
Terapia de Protones , Terapia de Protones/métodos , Tomografía Computarizada por Rayos X/métodos , Calibración , Reproducibilidad de los Resultados , Tomógrafos Computarizados por Rayos X , Fantasmas de Imagen
5.
Artículo en Inglés | MEDLINE | ID: mdl-38971383

RESUMEN

Although rare cancers, ocular tumors are a threat to vision, quality of life, and potentially life expectancy of a patient. Ocular proton therapy (OPT) is a powerful tool for successfully treating this disease. The Particle Therapy Co-Operative Ocular Group (PTCOG Ocular) formulated an Evidence and Expert-Based Executive Summary of Current Practices and Future Developments in OPT: Comparative dosimetric and clinical analysis with the different OPT systems is essential to set up planning guidelines, implement best practices, and establish benchmarks for eye preservation, vision, and quality of life measures. Contemporary prospective trials in select subsets of patients (e.g., tumors near the optic disc and/or macula) may allow for dosimetric and clinical analysis between different radiation modalities and beamline systems to evaluate differences in radiation delivery and penumbra, and resultant tumor control, normal tissue complication rates, and overall clinical cost-effectiveness. To date, the combination of multimodal imaging (fundus photography, ultrasound, etc.), ophthalmologist assessment, and clip surgery with radiation planning have been keys to successful treatment. Increased use of 3D imaging (CT/MRI) is anticipated although its spatial resolution might be a limiting factor (e.g., detection of flat diffuse tumor parts). Commercially produced ocular treatment planning systems are under development and their future use is expected to expand across OPT centers. Future continuity of OPT will depend on (i) maintaining and upgrading existing older dedicated low-energy facilities, (ii) maintaining shared, degraded beamlines at large proton therapy centers, and (iii) developing adapted gantry beams of sufficient quality to maintain the clinical benefits of sharp beam conformity. Option (i) potentially offers the sharpest beams, minimizing impact on healthy tissues, whilst (ii) and (iii) potentially offer the advantage of substantial long-term technical support and development as well as the introduction of new approaches. Significant patient throughputs and close cooperation between medical physics, ophthalmology, and radiotherapy, underpinned by mutual understanding, is crucial for a successful OPT service.

6.
Cancers (Basel) ; 15(23)2023 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-38067283

RESUMEN

(1) Background: Our purpose is to describe the design of a phase II clinical trial on 5-fraction proton therapy for chordomas and chondrosarcomas of the skull base and to present early results in terms of local control and clinical tolerance of the first prospective series. (2) Methods: A dose of 37.5 GyRBE in five fractions was proposed for chordomas and 35 GyRBE in five fractions for chondrosarcomas. The established inclusion criteria are age ≥ 18 years, Karnofsky Performance Status ≥ 70%, clinical target volume up to 50 cc, and compliance with dose restrictions to the critical organs. Pencil beam scanning was used for treatment planning, employing four to six beams. (3) Results: A total of 11 patients (6 chordomas and 5 chondrosarcomas) were included. The median follow-up was 12 months (9-15 months) with 100% local control. Acute grade I-II headache (64%), grade I asthenia and alopecia (45%), grade I nausea (27%), and grade I dysphagia (18%) were described. Late toxicity was present in two patients with grade 3 temporal lobe necrosis. (4) Conclusions: Hypofractionated proton therapy is showing encouraging preliminary results. However, to fully assess the efficacy of this therapeutic approach, future trials with adequate sample sizes and extended follow-ups are necessary.

7.
Med Phys ; 50(5): 3184-3190, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36852682

RESUMEN

BACKGROUND: Recent proposals of high dose rate plans in protontherapy as well as very short proton bunches may pose problems to current beam monitor systems. There is an increasing demand for real-time proton beam monitoring with high temporal resolution, extended dynamic range and radiation hardness. Plastic scintillators coupled to optical fiber sensors have great potential in this context to become a practical solution towards clinical implementation. PURPOSE: In this work, we evaluate the capabilities of a very compact fast plastic scintillator with an optical fiber readout by a SiPM and electronics sensor which has been used to provide information on the time structure at the nanosecond level of a clinical proton beam. MATERIALS AND METHODS: A 3 × 3 × 3 mm3 plastic scintillator (EJ-232Q Eljen Technology) coupled to a 3 × 3 mm2 SiPM (MicroFJ-SMA-30035, Onsemi) has been characterized with a 70 MeV clinical proton beam accelerated in a Proteus One synchrocyclotron. The signal was read out by a high sampling rate oscilloscope (5 GS/s). By exposing the sensor directly to the proton beam, the time beam profile of individual spots was recorded. RESULTS: Measurements of detector signal have been obtained with a time sampling period of 0.8 ns. Proton bunch period (16 ns), spot (10 µs) and interspot (1 ms) time structures could be observed in the time profile of the detector signal amplitude. From this, the RF frequency of the accelerator has been extracted, which is found to be 64 MHz. CONCLUSIONS: The proposed system was able to measure the fine time structure of a clinical proton accelerator online and with ns time resolution.


Asunto(s)
Terapia de Protones , Conteo por Cintilación , Fibras Ópticas , Protones , Plásticos
8.
Med Phys ; 49(3): 2039-2054, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34644403

RESUMEN

We review the current status of proton FLASH experimental systems, including preclinical physical and biological results. Technological limitations on preclinical investigation of FLASH biological mechanisms and determination of clinically relevant parameters are discussed. A review of the biological data reveals no reproduced proton FLASH effect in vitro and a significant in vivo FLASH sparing effect of normal tissue toxicity observed with multiple proton FLASH irradiation systems. Importantly, multiple studies suggest little or no difference in tumor growth delay for proton FLASH when compared to conventional dose rate proton radiation. A discussion follows on future areas of development with a focus on the determination of the optimal parameters for maximizing the therapeutic ratio between tumor and normal tissue response and ultimately clinical translation of proton FLASH radiation.


Asunto(s)
Neoplasias , Terapia de Protones , Humanos , Terapia de Protones/métodos , Protones , Radiación Ionizante , Dosificación Radioterapéutica
9.
Med Phys ; 49(3): 2026-2038, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35032035

RESUMEN

PURPOSE: In ultrahigh dose rate radiotherapy, the FLASH effect can lead to substantially reduced healthy tissue damage without affecting tumor control. Although many studies show promising results, the underlying biological mechanisms and the relevant delivery parameters are still largely unknown. It is unclear, particularly for scanned proton therapy, how treatment plans could be optimized to maximally exploit this protective FLASH effect. MATERIALS AND METHODS: To investigate the potential of pencil beam scanned proton therapy for FLASH treatments, we present a phenomenological model, which is purely based on experimentally observed phenomena such as potential dose rate and dose thresholds, and which estimates the biologically effective dose during FLASH radiotherapy based on several parameters. We applied this model to a wide variety of patient geometries and proton treatment planning scenarios, including transmission and Bragg peak plans as well as single- and multifield plans. Moreover, we performed a sensitivity analysis to estimate the importance of each model parameter. RESULTS: Our results showed an increased plan-specific FLASH effect for transmission compared with Bragg peak plans (19.7% vs. 4.0%) and for single-field compared with multifield plans (14.7% vs. 3.7%), typically at the cost of increased integral dose compared to the clinical reference plan. Similar FLASH magnitudes were found across the different treatment sites, whereas the clinical benefits with respect to the clinical reference plan varied strongly. The sensitivity analysis revealed that the threshold dose as well as the dose per fraction strongly impacted the FLASH effect, whereas the persistence time only marginally affected FLASH. An intermediate dependence of the FLASH effect on the dose rate threshold was found. CONCLUSIONS: Our model provided a quantitative measure of the FLASH effect for various delivery and patient scenarios, supporting previous assumptions about potentially promising planning approaches for FLASH proton therapy. Positive clinical benefits compared to clinical plans were achieved using hypofractionated, single-field transmission plans. The dose threshold was found to be an important factor, which may require more investigation.


Asunto(s)
Terapia de Protones , Oncología por Radiación , Radioterapia de Intensidad Modulada , Humanos , Terapia de Protones/métodos , Protones , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
10.
Phys Med Biol ; 66(11)2021 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-33910190

RESUMEN

Passive dosimetry with radiochromic films is widely used in proton radiotherapy, both in clinical and scientific environments, thanks to its simplicity, high spatial resolution and dose-rate independence. However, film under-response for low-energy protons, the so-called linear-energy transfer (LET) quenching, must be accounted and corrected for. We perform a meta-analysis on existing film under-response data with EBT, EBT2 and EBT3 GAFchromic™ films and provide a common framework to integrate it, based on the calculation of dose-averaged LET in the active layer of the films. We also report on direct measurements with the 10 MeV proton beam at the Center for Microanalysis of Materials (CMAM) for EBT2, EBT3 and unlaminated EBT3 films, focusing on the 20-80 keVµm-1LET range, where previous data was scarce. Measured film relative efficiency (RE) values are in agreement with previously reported data from the literature. A model on film RE constructed with combined literature and own experimental values in the 5-80 keVµm-1LET range is presented, supporting the hypothesis of a linear decrease of RE with LET, with no remarkable differences between the three types of films analyzed.


Asunto(s)
Dosimetría por Película , Protones , Calibración , Radiometría
11.
Br J Radiol ; 93(1107): 20190807, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32003574

RESUMEN

After years of lethargy, studies on two non-conventional microstructures in time and space of the beams used in radiation therapy are enjoying a huge revival. The first effect called "FLASH" is based on very high dose-rate irradiation (pulse amplitude ≥106 Gy/s), short beam-on times (≤100 ms) and large single doses (≥10 Gy) as experimental parameters established so far to give biological and potential clinical effects. The second effect relies on the use of arrays of minibeams (e.g., 0.5-1 mm, spaced 1-3.5 mm). Both approaches have been shown to protect healthy tissues as an endpoint that must be clearly specified and could be combined with each other (e.g., minibeams under FLASH conditions). FLASH depends on the presence of oxygen and could proceed from the chemistry of peroxyradicals and a reduced incidence on DNA and membrane damage. Minibeams action could be based on abscopal effects, cell signalling and/or migration of cells between "valleys and hills" present in the non-uniform irradiation field as well as faster repair of vascular damage. Both effects are expected to maintain intact the tumour control probability and might even preserve antitumoural immunological reactions. FLASH in vivo experiments involving Zebrafish, mice, pig and cats have been done with electron beams, while minibeams are an intermediate approach between X-GRID and synchrotron X-ray microbeams radiation. Both have an excellent rationale to converge and be applied with proton beams, combining focusing properties and high dose rates in the beam path of pencil beams, and the inherent advantage of a controlled limited range. A first treatment with electron FLASH (cutaneous lymphoma) has recently been achieved, but clinical trials have neither been presented for FLASH with protons, nor under the minibeam conditions. Better understanding of physical, chemical and biological mechanisms of both effects is essential to optimize the technical developments and devise clinical trials.


Asunto(s)
Tratamientos Conservadores del Órgano/métodos , Terapia de Protones/métodos , Animales , Gatos , Proliferación Celular , Daño del ADN , Reparación del ADN , Fraccionamiento de la Dosis de Radiación , Linfoma Cutáneo de Células T/radioterapia , Ratones , Órganos en Riesgo/efectos de la radiación , Oxígeno , Consumo de Oxígeno , Traumatismos por Radiación/prevención & control , Tolerancia a Radiación , Radiometría/métodos , Neoplasias Cutáneas/radioterapia , Análisis Espacio-Temporal , Porcinos , Pez Cebra
12.
Adv Radiat Oncol ; 5(4): 682-686, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32337386

RESUMEN

Uveal melanoma (UM) is a rare but life-threatening cancer of the eye. In light of the coronavirus disease (COVID-19) pandemic, hospitals and proton eye therapy facilities must analyze several factors to ensure appropriate treatment protocols for patients and provider teams. Practice considerations to limit COVID-19 transmission in the proton ocular treatment setting for UM are necessary. The Particle Therapy Co-Operative Group is the largest international community of particle/proton therapy providers. Participating experts have current or former affiliation with the member institutions of the Particle Therapy Co-Operative Group Ocular subcommittee with long-standing high-volume proton ocular programs. The practices reviewed in this document must be taken in conjunction with local hospital procedures, multidisciplinary recommendations, and regional/national guidelines, as each community may have its unique needs, supplies, and protocols. Importantly, as the pandemic evolves, so will the strategies and recommendations. Given the unique circumstances for UM patients, along with indications of potential ophthalmologic transmission as a result of health care providers working in close proximity to patients and intrinsic infectious risk from eyelashes, tears, and hair, practice strategies may be adapted to reduce the risk of viral transmission. Certainly, providers and health care systems will continue to examine and provide as safe and effective care as possible for patients in the current environment.

13.
Front Oncol ; 10: 613669, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33585238

RESUMEN

Proton therapy has advantages and pitfalls comparing with photon therapy in radiation therapy. Among the limitations of protons in clinical practice we can selectively mention: uncertainties in range, lateral penumbra, deposition of higher LET outside the target, entrance dose, dose in the beam path, dose constraints in critical organs close to the target volume, organ movements and cost. In this review, we combine proposals under study to mitigate those pitfalls by using individually or in combination: (a) biological approaches of beam management in time (very high dose rate "FLASH" irradiations in the order of 100 Gy/s) and (b) modulation in space (a combination of mini-beams of millimetric extent), together with mechanical approaches such as (c) rotational techniques (optimized in partial arcs) and, in an effort to reduce cost, (d) gantry-less delivery systems. In some cases, these proposals are synergic (e.g., FLASH and minibeams), in others they are hardly compatible (mini-beam and rotation). Fixed lines have been used in pioneer centers, or for specific indications (ophthalmic, radiosurgery,…), they logically evolved to isocentric gantries. The present proposals to produce fixed lines are somewhat controversial. Rotational techniques, minibeams and FLASH in proton therapy are making their way, with an increasing degree of complexity in these three approaches, but with a high interest in the basic science and clinical communities. All of them must be proven in clinical applications.

14.
Med Phys ; 36(3): 816-20, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19378742

RESUMEN

A simple device to check the machine output in rotational mode is described. Integral and instantaneous beam output in absolute dose can be measured and analyzed in a very simple manner. A method to correlate the results with the value obtained during the machine calibration in static beam and the reference value used by the treatment planning system for dose calculation in rotation beam is also described. Using this method and device, the daily output can be performed in rotational conditions which are closer to the treatment conditions. Measurement results using this device show differences in the beam output between static and rotational delivery which have to be considered carefully during the calibration process.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador/estadística & datos numéricos , Radioterapia de Intensidad Modulada/instrumentación , Fenómenos Biofísicos , Humanos , Neoplasias/radioterapia , Radioterapia de Alta Energía/instrumentación , Radioterapia de Alta Energía/estadística & datos numéricos , Radioterapia de Intensidad Modulada/estadística & datos numéricos , Rotación , Dispersión de Radiación
15.
Health Phys ; 117(5): 509-525, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31211755

RESUMEN

Patient-specific collimators used in proton therapy are activated after use. The aim of this work is to assess the residual activity in brass collimators considering clinical beams, so far studied only for monoenergetic beams, and to develop a model to calculate the activity. Eight brass collimators irradiated with different clinical and monoenergetic beams were included in the study. The collimators were analyzed with gamma spectrometry in the framework of three independent studies carried out at the two French proton therapy sites. Using FLUKA (a fully integrated particle physics Monte Carlo simulation package), simulations were performed to determine radionuclides and activities for all the collimators. The semiempirical model was built using data calculated with FLUKA for a range of clinical beams (different maximum proton energies, modulations, and doses). It was found that there was global coherence in experimental results from different studies. The relevant radionuclides at 1 mo postirradiation were Co, Co, and Zn, and additionally, Mn, Co, and Co for high-energy beams. For nondegraded monoenergetic beams, differences between FLUKA and spectrometry were within those reported in reference benchmark studies (±30%). Due to the use of perfect monochromatic sources in the FLUKA model, FLUKA results systematically underestimated experimental activities for clinical beams, especially for Zn, depending on the beam energy spread (modulation, degradation, beam line characteristics). To account for the energy spread, correction factors were derived for the semiempirical model. The model is applicable to the most relevant radionuclides and total amounts. Secondary neutrons have a negligible contribution to the activity during treatment with respect to proton activation.


Asunto(s)
Algoritmos , Modelos Estadísticos , Método de Montecarlo , Terapia de Protones/instrumentación , Terapia de Protones/métodos , Radiometría/instrumentación , Humanos , Dosis de Radiación
16.
Int J Radiat Oncol Biol Phys ; 102(3): 619-626, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-30017793

RESUMEN

PURPOSE: Recent in vivo investigations have shown that short pulses of electrons at very high dose rates (FLASH) are less harmful to healthy tissues but just as efficient as conventional dose-rate radiation to inhibit tumor growth. In view of the potential clinical value of FLASH and the availability of modern proton therapy infrastructures to achieve this goal, we herein describe a series of technological developments required to investigate the biology of FLASH irradiation using a commercially available clinical proton therapy system. METHODS AND MATERIALS: Numerical simulations and experimental dosimetric characterization of a modified clinical proton beamline, upstream from the isocenter, were performed with a Monte Carlo toolkit and different detectors. A single scattering system was optimized with a ridge filter and a high current monitoring system. In addition, a submillimetric set-up protocol based on image guidance using a digital camera and an animal positioning system was also developed. RESULTS: The dosimetric properties of the resulting beam and monitoring system were characterized; linearity with dose rate and homogeneity for a 12 × 12 mm2 field size were assessed. Dose rates exceeding 40 Gy/s at energies between 138 and 198 MeV were obtained, enabling uniform irradiation for radiobiology investigations of small animals in a modified clinical proton beam line. CONCLUSIONS: This approach will enable us to conduct FLASH proton therapy experiments on small animals, specifically for mouse lung irradiation. Dose rates exceeding 40 Gy/s were achieved, which was not possible with the conventional clinical mode of the existing beamline.


Asunto(s)
Neoplasias/radioterapia , Terapia de Protones/instrumentación , Animales , Calibración , Simulación por Computador , Modelos Animales de Enfermedad , Diseño de Equipo , Pulmón/efectos de la radiación , Ratones , Método de Montecarlo , Protones , Radiobiología , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
17.
Phys Med Biol ; 62(13): 5417-5439, 2017 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-28604370

RESUMEN

The scope of this work was to develop a synthetic single crystal diamond dosimeter (SCDD-Pro) for accurate relative dose measurements of clinical proton beams in water. Monte Carlo simulations were carried out based on the MCNPX code in order to investigate and reduce the dose curve perturbation caused by the SCDD-Pro. In particular, various diamond thicknesses were simulated to evaluate the influence of the active volume thickness (e AV) as well as the influence of the addition of a front silver resin (250 µm in thickness in front of the diamond crystal) on depth-dose curves. The simulations indicated that the diamond crystal alone, with a small e AV of just 5 µm, already affects the dose at Bragg peak position (Bragg peak dose) by more than 2% with respect to the Bragg peak dose deposited in water. The optimal design that resulted from the Monte Carlo simulations consists of a diamond crystal of 1 mm in width and 150 µm in thickness with the front silver resin, enclosed by a water-equivalent packaging. This design leads to a deviation between the Bragg peak dose from the full detector modeling and the Bragg peak dose deposited in water of less than 1.2%. Based on those optimizations, an SCDD-Pro prototype was built and evaluated in broad passive scattering proton beams. The experimental evaluation led to probed SCDD-Pro repeatability, dose rate dependence and linearity, that were better than 0.2%, 0.4% (in the 1.0-5.5 Gy min-1 range) and 0.4% (for dose higher than 0.05 Gy), respectively. The depth-dose curves in the 90-160 MeV energy range, measured with the SCDD-Pro without applying any correction, were in good agreement with those measured using a commercial IBA PPC05 plane-parallel ionization chamber, differing by less than 1.6%. The experimental results confirmed that this SCDD-Pro is suitable for measurements with standard electrometers and that the depth-dose curve perturbation is negligible, with no energy dependence and no significant dose rate dependence.


Asunto(s)
Diamante , Terapia de Protones , Radiometría/métodos , Método de Montecarlo , Dosificación Radioterapéutica , Dispersión de Radiación , Agua
18.
Bull Cancer ; 104(4): 380-384, 2017 Apr.
Artículo en Francés | MEDLINE | ID: mdl-28283183

RESUMEN

In this review, we present the synthesis of the newly acquired knowledge concerning high dose-rate irradiations and the hopes that these new radiotherapy modalities give rise to. The results were presented at a recent symposium on the subject.


Asunto(s)
Neoplasias/radioterapia , Dosificación Radioterapéutica , Animales , Electrones/uso terapéutico , Humanos , Ratones , Terapia de Protones , Radioterapia/efectos adversos , Radioterapia/instrumentación , Radioterapia/métodos
19.
Int J Radiat Oncol Biol Phys ; 65(3): 780-7, 2006 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-16647221

RESUMEN

PURPOSE: This study reports the results of proton beam radiotherapy based on a retrospective series of patients treated for uveal melanoma at the Orsay Center. METHODS AND MATERIALS: Between September 1991 and September 2001, 1,406 patients with uveal melanoma were treated by proton beam radiotherapy. A total dose of 60 cobalt Gray equivalent (CGE) was delivered in 4 fractions on 4 days. Survival rates were determined using Kaplan-Meier estimates. Prognostic factors were determined by multivariate analysis using the Cox model. RESULTS: The median follow-up was 73 months (range, 24-142 months). The 5-year overall survival and metastasis-free survival rates were 79% and 80.6%, respectively. The 5-year local control rate was 96%. The 5-year enucleation for complications rate was 7.7%. Independent prognostic factors for overall survival were age (p < 0.0001), gender (p < 0.0003), tumor site (p < 0.0001), tumor thickness (p = 0.02), tumor diameter (p < 0.0001), and retinal area receiving at least 30 CGE (p = 0.003). Independent prognostic factors for metastasis-free survival were age (p = 0.0042), retinal detachment (p = 0.01), tumor site (p < 0.0001), tumor volume (p < 0.0001), local recurrence (p < 0.0001), and retinal area receiving at least 30 CGE (p = 0.002). Independent prognostic factors for local control were tumor diameter (p = 0.003) and macular area receiving at least 30 CGE (p = 0.01). Independent prognostic factors for enucleation for complications were tumor thickness (p < 0.0001) and lens volume receiving at least 30 CGE (p = 0.0002). CONCLUSION: This retrospective study confirms that proton beam radiotherapy ensures an excellent local control rate. Further clinical studies are required to decrease the incidence of postirradiation ocular complications.


Asunto(s)
Melanoma/radioterapia , Terapia de Protones , Neoplasias de la Úvea/radioterapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Supervivencia sin Enfermedad , Fraccionamiento de la Dosis de Radiación , Enucleación del Ojo/estadística & datos numéricos , Femenino , Humanos , Melanoma/mortalidad , Persona de Mediana Edad , Recurrencia Local de Neoplasia/radioterapia , Recurrencia Local de Neoplasia/cirugía , Estudios Retrospectivos , Tasa de Supervivencia , Neoplasias de la Úvea/mortalidad
20.
Radiother Oncol ; 79(2): 208-10, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16712991

RESUMEN

We have designed a simple benchmark test for the user of a treatment planning system to check the calculation algorithm's ability to model the build up effect beyond an air/tissue interface. The expected result is expressed as an inhomogeneity correction factor CF derived from measurements and from Monte Carlo calculations for a full range of photon beam qualities. The linear regression lines obtained from plotting CF as a function of beam quality index form the basis for a quantitative check of the algorithm performance.


Asunto(s)
Algoritmos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Aire , Benchmarking , Humanos , Fantasmas de Imagen