Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Int Orthop ; 48(2): 419-426, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37672119

RESUMEN

PURPOSE: Short stems for total hip arthroplasty are an alternative to traditional conventional long stems. Short stems are designed to facilitate minimal-invasive surgery, improve bone-stock preservation, and mimic a physiological load distribution. However, there is little evidence of the long-term outcome of short stems. This study aims to analyze the ten year survival rates and clinical outcome of one specific metaphyseal short hip stem implant. METHODS: We retrospectively analyzed the patient records of the patients who underwent a total hip arthroplasty with a monoblock partial collum sparing metaphyseal short hip stem prosthesis in 2008 and 2009 in our clinic. Patients were contacted, and clinical follow-up was recorded using the German version of the modified Harris Hip Score. Furthermore, complications, revision surgery, and post-operative radiographs were analyzed. RESULTS: Data from 339 primary implantations in 322 patients were retrieved. The mean follow-up was 10.6 years. Seven patients underwent a revision. The ten year survival rate with any revision surgery as the endpoint was 97.5%. The mean modified Harris Hip Score was 86 points (range 30 to 91 points). Five patients had an intraoperative fracture of the femur (1.6%). Two patients (0.6%) had a dislocation of the hip. The stem tip-to-cortex distance, measured in the anterior posterior view, was 2.6 mm (range 0 to 8.3 mm). CONCLUSION: The ten year survival rate of our used monoblock partial collum sparing metaphyseal short hip stem implant is comparable to traditional stems for total hip arthroplasty.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios Retrospectivos , Estudios de Seguimiento , Diseño de Prótesis , Prótesis de Cadera/efectos adversos , Reoperación , Resultado del Tratamiento , Falla de Prótesis
2.
Int J Oral Maxillofac Surg ; 52(11): 1137-1144, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37019734

RESUMEN

The stability of a microvascular anastomosis is an important prerequisite for successful tissue transfer. Advances in tissue adhesives are potentially opening new avenues for their use in sutureless microsurgical anastomosis, however they have not yet gained clinical acceptance. In this ex vivo study, a novel polyurethane-based adhesive (PA) was used in sutureless anastomoses and its stability compared with that of sutureless anastomoses performed with fibrin glue (FG) and a cyanoacrylate (CA). Stability was assessed using hydrostatic (15 per group) and mechanical tests (13 per group). A total of 84 chicken femoral arteries were used in this study. The time taken to create the PA and CA anastomoses was significantly faster when compared to the FG anastomoses (P < 0.001): 1.55 ± 0.14 min and 1.39 ± 0.06 min, respectively, compared to 2.03 ± 0.35 min. Both sustained significantly higher pressures (289.3 mmHg and 292.7 mmHg, respectively) than anastomoses using FG (137.3 mmHg) (P < 0.001). CA anastomoses (0.99 N; P < 0.001) and PA anastomoses (0.38 N; P = 0.009) could both withstand significantly higher longitudinal tensile forces compared to FG anastomoses (0.10 N). Considering the background of an in vitro study, the PA and CA anastomosis techniques were shown to be similar to each other and superior to FG, due to their stability and faster handling. These findings need to be validated and confirmed in further in vivo studies.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA