Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
J Vasc Surg ; 77(2): 446-453.e3, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36028158

RESUMEN

OBJECTIVE: This study reports the results of a prospective, multicenter trial designed to evaluate the safety and effectiveness of the polymer based Endologix Alto Stent Graft System in treating abdominal aortic aneurysms (AAAs), with sealing 7 mm below the top of the fabric in aortic neck diameters from 16 to 30 mm. METHODS: Seventy-five patients were treated with Alto devices between March 2017 and February 2018 in 16 centers in the United States for infrarenal AAAs (max diameter ≥5.0 cm in diameter or size increase by 0.5 cm in 6 months or diameter ≥1.5 times the adjacent normal aorta). Patients were followed for 30 days, 6 months, and 1 year by clinical evaluation and computed tomography and abdominal x-ray imaging. Treatment success was defined as technical success and freedom from AAA enlargement, migration, type I or III endoleak, AAA rupture or surgical conversion, stent graft stenosis, occlusion, kink, thromboembolic events, and stent fracture attributable to the device requiring secondary intervention through 12 months. Preoperative characteristics, perioperative variables, follow-up clinical evaluations, and radiographic examination results through the first 1 year were analyzed. RESULTS: The mean patient age was 73 years, with 93% of patients being male. The 30-day major adverse event rate was 5.3%. At 1 year, the primary endpoint was met with a treatment success rate of 96.7%. Through 1-year post-treatment, all-cause mortality was 4.0%. No AAA-related mortality occurred. AAA enlargement was 1.6%, type I endoleak rate was 1.4%, with 100% freedom from type III endoleaks, device migration, device fracture, stent occlusion, or AAA rupture. The device-related secondary intervention rate was 2.7%. CONCLUSIONS: This prospective study demonstrates the Endologix Alto is safe and effective in treating AAAs with appropriate anatomy at 1 year. The safety endpoint is met by a 5.3% 30-day major adverse event rate, whereas the effectiveness endpoint is met by a treatment success rate of 96%.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Masculino , Estados Unidos , Anciano , Femenino , Prótesis Vascular/efectos adversos , Estudios Prospectivos , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/terapia , Diseño de Prótesis , Stents/efectos adversos , Resultado del Tratamiento , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones
2.
Catheter Cardiovasc Interv ; 97(6): 1120-1126, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-32649037

RESUMEN

BACKGROUND: Supersaturated oxygen (SSO2 ) has recently been approved by the U.S. Food and Drug Administration for administration after primary percutaneous coronary intervention (pPCI) in patients with anterior ST-segment elevation myocardial infarction (STEMI) based on its demonstration of infarct size reduction in the IC-HOT study. OBJECTIVES: To describe the 1-year clinical outcomes of intracoronary SSO2 treatment after pPCI in patients with anterior STEMI. METHODS: IC-HOT was a prospective, open-label, single-arm study in which 100 patients without cardiogenic shock undergoing successful pPCI of an occluded left anterior descending coronary artery were treated with a 60-min SSO2 infusion. One-year clinical outcomes were compared with a propensity-matched control group of similar patients with anterior STEMI enrolled in the INFUSE-AMI trial. RESULTS: Baseline and postprocedural characteristics were similar in the two groups except for pre-PCI thrombolysis in myocardial infarction 3 flow, which was less prevalent in patients treated with SSO2 (9.6% vs. 22.9%, p = .02). Treatment with SSO2 was associated with a lower 1-year rate of the composite endpoint of all-cause death or new-onset heart failure (HF) or hospitalization for HF (0.0% vs. 12.3%, p = .001). All-cause mortality, driven by cardiovascular mortality, and new-onset HF or HF hospitalization were each individually lower in SSO2 -treated patients. There were no significant differences between groups in the 1-year rates of reinfarction or clinically driven target vessel revascularization. CONCLUSIONS: Infusion of SSO2 following pPCI in patients with anterior STEMI was associated with improved 1-year clinical outcomes including lower rates of death and new-onset HF or HF hospitalizations.


Asunto(s)
Infarto del Miocardio , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/terapia , Oxígeno , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/terapia , Resultado del Tratamiento
3.
Circulation ; 140(23): 1895-1903, 2019 12 03.
Artículo en Inglés | MEDLINE | ID: mdl-31553222

RESUMEN

BACKGROUND: The Absorb everolimus-eluting bioresorbable vascular scaffold (BVS) provides early drug delivery and mechanical support similar to those of metallic drug-eluting stents, followed by complete resorption in ≈3 years with recovery of vascular structure and function. The ABSORB III trial demonstrated noninferior rates of target lesion failure (cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization) at 1 year with BVS compared with cobalt chromium everolimus-eluting stents. Between 1 and 3 years and cumulative to 3 years, adverse event rates (particularly target vessel myocardial infarction and scaffold thrombosis) were increased after BVS. We sought to assess clinical outcomes after BVS through 5 years, including beyond the 3-year time point of complete scaffold resorption. METHODS: Clinical outcomes from ABSORB III were analyzed by randomized device (intention to treat) cumulative to 5 years and between 3 and 5 years. RESULTS: Rates of target lesion failure, target vessel myocardial infarction, and scaffold thrombosis were increased through the 5-year follow-up with BVS compared with everolimus-eluting stents. However, between 3 and 5 years, reductions in the relative hazards of the BVS compared with everolimus-eluting stents were observed, particularly for target lesion failure (hazard ratio, 0.83 [95% CI, 0.55-1.24] versus 1.35 [95% CI, 1.02-1.78]; Pint=0.052) and scaffold thrombosis (hazard ratio, 0.26 [95% CI, 0.02-2.87] versus 3.23 [95% CI, 1.25-8.30]; Pint=0.056) compared with the 0- to 3-year time period. CONCLUSIONS: In the ABSORB III trial, cumulative 5-year adverse event rates were increased after BVS compared with everolimus-eluting stents. However, the period of excess risk for BVS ended at 3 years, coincident with complete scaffold resorption. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov. Unique identifier: NCT01751906.


Asunto(s)
Implantes Absorbibles , Estenosis Coronaria/cirugía , Implantes de Medicamentos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea , Aleaciones de Cromo , Ensayos Clínicos Fase III como Asunto/estadística & datos numéricos , Trombosis Coronaria/epidemiología , Stents Liberadores de Fármacos , Estudios de Equivalencia como Asunto , Everolimus/uso terapéutico , Estudios de Seguimiento , Humanos , Estudios Multicéntricos como Asunto/estadística & datos numéricos , Infarto del Miocardio/epidemiología , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto/estadística & datos numéricos , Método Simple Ciego , Andamios del Tejido , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 96(4): 793-801, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31721430

RESUMEN

OBJECTIVES: We sought to compare clinical outcomes after percutaneous coronary intervention (PCI) in patients on versus not on hemodialysis (HD) and examine whether high on-treatment platelet reactivity (HPR) further impacts outcomes among patients on HD. BACKGROUND: Both chronic kidney disease (CKD) and HPR are predictors of major adverse cardiac events (MACE) after PCI. METHODS: Two-year outcomes of patients from the prospective, multicenter ADAPT-DES study (N = 8,582) were analyzed according to HD status at enrollment. All patients underwent platelet function testing with the VerifyNow assay; HPR on clopidogrel was defined as P2Y12 reaction units (PRU) >208. RESULTS: Compared with non-HD patients, patients on HD (n = 85) had significantly higher baseline PRU (median 254 vs. 188, p = .001) and more frequently had HPR (61.7% vs. 42.5%, p < .001). HD was associated with increased 2-year rates of MACE (death, myocardial infarction (MI) or definite stent thrombosis (ST); 23.4% vs. 10.7%, p < .001). HD was also strongly associated with 2-year overall mortality, cardiac death, MI, target vessel revascularization, major bleeding, stroke and ST. Following adjustment for HPR and other covariates, HD was independently associated with overall mortality, MI, ST, and major bleeding at 2 years. The relationship between HD status and 2-year MACE was consistent in patients with and without HPR (Pinteraction = .78). CONCLUSIONS: Nearly two-thirds of patients on HD exhibited HPR on clopidogrel, and both HD and HPR were independently associated with 2-year adverse outcomes after DES implantation. However, the deleterious impact of HD on clinical outcomes was present in both patients with and without HPR.


Asunto(s)
Aspirina/uso terapéutico , Clopidogrel/uso terapéutico , Enfermedad de la Arteria Coronaria/terapia , Terapia Antiplaquetaria Doble , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/uso terapéutico , Diálisis Renal , Insuficiencia Renal Crónica/terapia , Anciano , Aspirina/efectos adversos , Clopidogrel/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/mortalidad , Trombosis Coronaria/prevención & control , Stents Liberadores de Fármacos , Terapia Antiplaquetaria Doble/efectos adversos , Terapia Antiplaquetaria Doble/mortalidad , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/mortalidad , Inhibidores de Agregación Plaquetaria/efectos adversos , Pruebas de Función Plaquetaria , Estudios Prospectivos , Sistema de Registros , Diálisis Renal/efectos adversos , Diálisis Renal/mortalidad , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/mortalidad , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
5.
Lancet ; 392(10157): 1530-1540, 2018 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-30266412

RESUMEN

BACKGROUND: Previous studies showed more adverse events with coronary bioresorbable vascular scaffolds (BVS) than with metallic drug-eluting stents (DES), although in one randomised trial angina was reduced with BVS. However, these early studies were unmasked, lesions smaller than intended for the scaffold were frequently enrolled, implantation technique was suboptimal, and patients with myocardial infarction, in whom BVS might be well suited, were excluded. METHODS: In the active-controlled, blinded, multicentre, randomised ABSORB IV trial, patients with stable coronary artery disease or acute coronary syndromes aged 18 years or older were recruited from 147 hospitals in five countries (the USA, Germany, Australia, Singapore, and Canada). Enrolled patients were randomly assigned (1:1) to receive polymeric everolimus-eluting BVS (Absorb; Abbott Vascular, Santa Clara, CA, USA) with optimised implantation technique or cobalt-chromium everolimus-eluting stents (EES; Xience; Abbott Vascular, Santa Clara, CA, USA). Randomisation was stratified by diabetic status, whether patients would have been eligible for enrolment in the previous ABSORB III trial, and site. Patients and clinical assessors were masked to randomisation. The primary endpoint was target lesion failure (cardiac death, target vessel myocardial infarction, or ischaemia-driven target lesion revascularisation) at 30 days, tested for non-inferiority with a 2·9% margin for the risk difference. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT02173379, and is closed to accrual. FINDINGS: Between Aug 15, 2014, and March 31, 2017, we screened 18 722 patients for eligibility, 2604 of whom were enrolled. 1296 patients were assigned to BVS, and 1308 patients were assigned to EES. Follow-up data at 30 days and 1 year, respectively, were available for 1288 and 1254 patients with BVS and for 1303 and 1272 patients with EES. Biomarker-positive acute coronary syndromes were present in 622 (24%) of 2602 patients, and, by angiographic core laboratory analysis, 78 (3%) of 2893 of lesions were in very small vessels. Target lesion failure at 30 days occurred in 64 (5·0%) patients assigned to BVS and 48 (3·7%) patients assigned to EES (difference 1·3%, upper 97·5% confidence limit 2·89; one-sided pnon-inferiority=0·0244). Target lesion failure at 1 year occurred in 98 (7·8%) patients assigned to BVS and 82 (6·4%) patients assigned to EES (difference 1·4%, upper 97·5% confidence limit 3·4; one-sided pnon-inferiority=0·0006). Angina, adjudicated by a central events committee at 1 year, occurred in 270 (20·3%) patients assigned to BVS and 274 (20·5%) patients assigned to EES (difference -0·3%, 95% CI -3·4% to 2·9%; one-sided pnon-inferiority=0·0008; two-sided psuperiority=0·8603). Device thrombosis within 1 year occurred in nine (0·7%) patients assigned to BVS and four (0·3%) patients assigned to EES (p=0·1586). INTERPRETATION: Polymeric BVS implanted with optimised technique in an expanded patient population resulted in non-inferior 30-day and 1-year rates of target lesion failure and angina compared with metallic DES. FUNDING: Abbott Vascular.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/terapia , Andamios del Tejido , Síndrome Coronario Agudo/terapia , Anciano , Materiales Biocompatibles , Enfermedad de la Arteria Coronaria/patología , Método Doble Ciego , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Femenino , Estudios de Seguimiento , Humanos , Inmunosupresores/administración & dosificación , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
6.
Am Heart J ; 211: 68-76, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30897527

RESUMEN

BACKGROUND: Chronic total occlusion (CTO) percutaneous coronary intervention (PCI) typically requires a greater number of stents and longer stent length than non-CTO PCI, placing these patients at greater risk for adverse ischemic events. We sought to determine whether the association between high platelet reactivity (HPR) and the risk of ischemic events is stronger after CTO than non-CTO PCI. METHODS: Patients undergoing successful PCI in the multicenter ADAPT-DES study were stratified according to whether they underwent PCI of a CTO. HPR was defined as VerifyNow platelet reaction units >208. The study primary endpoint was the 2-year risk target vessel failure ([TVF] defined as cardiac death, myocardial infarction, or target lesion revascularization). RESULTS: CTO PCI was performed in 400 of 8448 patients. HPR was present in 34.5% of CTO PCI patients and 43.1% of non-CTO PCI patients (P = .0007). Patients undergoing CTO PCI with versus without HPR had significantly higher 2-year rates of TVF (15.0% versus 8.3%, P = .04) without significant differences in bleeding. HPR was an independent predictor of 2-year TVF (adjusted HR 1.16, 95% CI 1.02-1.34, P = .03) whereas CTO PCI was not (adjusted HR 0.89, 95% CI 0.65-1.22, P = .48). There was a significant interaction between CTO versus non-CTO PCI and PRU as a continuous variable for 2-year TVF (Pinteraction = 0.02). CONCLUSIONS: In ADAPT-DES, HPR was associated with an increased 2-year risk of TVF after PCI, an association that was at least as strong after CTO PCI compared with non-CTO PCI.


Asunto(s)
Plaquetas/fisiología , Oclusión Coronaria/sangre , Oclusión Coronaria/cirugía , Stents Liberadores de Fármacos/efectos adversos , Isquemia Miocárdica/etiología , Intervención Coronaria Percutánea/efectos adversos , Anciano , Aspirina/uso terapéutico , Femenino , Fibrinolíticos/uso terapéutico , Humanos , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/uso terapéutico , Complicaciones Posoperatorias , Estudios Prospectivos , Diseño de Prótesis
7.
Catheter Cardiovasc Interv ; 93(5): 882-890, 2019 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-30265429

RESUMEN

BACKGROUND: In the randomized AMIHOT-II trial, supersaturated oxygen [SSO2 ] delivered into the left anterior descending (LAD) artery via an indwelling intracoronary infusion catheter following primary percutaneous coronary intervention (PCI) significantly reduced infarct size in patients with anterior ST-segment elevation myocardial infarction (STEMI) but resulted in a numerically higher incidence of safety events. OBJECTIVES: The IC-HOT study evaluated the safety of SSO2 therapy selectively delivered to the left main coronary artery (LMCA) for 60 minutes after PCI in patients with anterior STEMI. METHODS: SSO2 therapy was administered to the LMCA after stent implantation in 100 patients with anterior STEMI and proximal or mid-LAD occlusion presenting within 6 hours of symptom onset. The primary endpoint was the 30-day composite rate of net adverse clinical events (NACE) (death, reinfarction, clinically driven target vessel revascularization, stent thrombosis, severe heart failure, or TIMI major/minor bleeding) compared against an objective performance goal of 10.7%. Cardiac magnetic resonance imaging was performed at 4 and 30 days to assess infarct size. RESULTS: SSO2 delivery was successful in 98% of patients. NACE at 30 days occurred 7.1% of patients (meeting the primary safety endpoint of the study); there were no deaths, only one stent thrombosis and one case of severe heart failure. Median [interquartile range] infarct size was 24.1% [14.4%, 31.6%] at 4 days and 19.4% [8.8%, 28.9%] at 30 days. CONCLUSION: Following primary PCI in acute anterior STEMI, infusion of SSO2 via the LMCA was feasible and was associated with a favorable early safety profile.


Asunto(s)
Infarto de la Pared Anterior del Miocardio/terapia , Cateterismo Cardíaco , Hiperoxia , Oxígeno/administración & dosificación , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST/terapia , Infarto de la Pared Anterior del Miocardio/diagnóstico por imagen , Trombosis Coronaria/etiología , Estudios de Factibilidad , Femenino , Insuficiencia Cardíaca/etiología , Humanos , Infusiones Intraarteriales , Imagen por Resonancia Magnética , Masculino , Oxígeno/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Estudios Prospectivos , Factores de Riesgo , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Stents , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
8.
N Engl J Med ; 373(20): 1905-15, 2015 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-26457558

RESUMEN

BACKGROUND: In patients with coronary artery disease who receive metallic drug-eluting coronary stents, adverse events such as late target-lesion failure may be related in part to the persistent presence of the metallic stent frame in the coronary-vessel wall. Bioresorbable vascular scaffolds have been developed to attempt to improve long-term outcomes. METHODS: In this large, multicenter, randomized trial, 2008 patients with stable or unstable angina were randomly assigned in a 2:1 ratio to receive an everolimus-eluting bioresorbable vascular (Absorb) scaffold (1322 patients) or an everolimus-eluting cobalt-chromium (Xience) stent (686 patients). The primary end point, which was tested for both noninferiority (margin, 4.5 percentage points for the risk difference) and superiority, was target-lesion failure (cardiac death, target-vessel myocardial infarction, or ischemia-driven target-lesion revascularization) at 1 year. RESULTS: Target-lesion failure at 1 year occurred in 7.8% of patients in the Absorb group and in 6.1% of patients in the Xience group (difference, 1.7 percentage points; 95% confidence interval, -0.5 to 3.9; P=0.007 for noninferiority and P=0.16 for superiority). There was no significant difference between the Absorb group and the Xience group in rates of cardiac death (0.6% and 0.1%, respectively; P=0.29), target-vessel myocardial infarction (6.0% and 4.6%, respectively; P=0.18), or ischemia-driven target-lesion revascularization (3.0% and 2.5%, respectively; P=0.50). Device thrombosis within 1 year occurred in 1.5% of patients in the Absorb group and in 0.7% of patients in the Xience group (P=0.13). CONCLUSIONS: In this large-scale, randomized trial, treatment of noncomplex obstructive coronary artery disease with an everolimus-eluting bioresorbable vascular scaffold, as compared with an everolimus-eluting cobalt-chromium stent, was within the prespecified margin for noninferiority with respect to target-lesion failure at 1 year. (Funded by Abbott Vascular; ABSORB III ClinicalTrials.gov number, NCT01751906.).


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Inmunosupresores/administración & dosificación , Anciano , Angina de Pecho/terapia , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria , Stents Liberadores de Fármacos/efectos adversos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Metales , Persona de Mediana Edad , Diseño de Prótesis
9.
N Engl J Med ; 373(2): 145-53, 2015 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-26106946

RESUMEN

BACKGROUND: The treatment of peripheral artery disease with percutaneous transluminal angioplasty is limited by the occurrence of vessel recoil and restenosis. Drug-coated angioplasty balloons deliver antiproliferative agents directly to the artery, potentially improving vessel patency by reducing restenosis. METHODS: In this single-blind, randomized trial conducted at 54 sites, we assigned, in a 2:1 ratio, 476 patients with symptomatic intermittent claudication or ischemic pain while at rest and angiographically significant atherosclerotic lesions to angioplasty with a paclitaxel-coated balloon or to standard angioplasty. The primary efficacy end point was primary patency of the target lesion at 12 months (defined as freedom from binary restenosis or from the need for target-lesion revascularization). The primary safety end point was a composite of freedom from perioperative death from any cause and freedom at 12 months from limb-related death (i.e., death from a medical complication related to a limb), amputation, and reintervention. RESULTS: The two groups were well matched at baseline; 42.9% of the patients had diabetes, and 34.7% were current smokers. At 12 months, the rate of primary patency among patients who had undergone angioplasty with the drug-coated balloon was superior to that among patients who had undergone conventional angioplasty (65.2% vs. 52.6%, P=0.02). The proportion of patients free from primary safety events was 83.9% with the drug-coated balloon and 79.0% with standard angioplasty (P=0.005 for noninferiority). There were no significant between-group differences in functional outcomes or in the rates of death, amputation, thrombosis, or reintervention. CONCLUSIONS: Among patients with symptomatic femoropopliteal peripheral artery disease, percutaneous transluminal angioplasty with a paclitaxel-coated balloon resulted in a rate of primary patency at 12 months that was higher than the rate with angioplasty with a standard balloon. The drug-coated balloon was noninferior to the standard balloon with respect to safety. (Funded by Lutonix-Bard; LEVANT 2 ClinicalTrials.gov number, NCT01412541.).


Asunto(s)
Angioplastia de Balón/instrumentación , Arteria Femoral , Paclitaxel/administración & dosificación , Enfermedad Arterial Periférica/terapia , Arteria Poplítea , Anciano , Angioplastia de Balón/efectos adversos , Complicaciones de la Diabetes/terapia , Femenino , Arteria Femoral/diagnóstico por imagen , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/mortalidad , Arteria Poplítea/diagnóstico por imagen , Radiografía , Método Simple Ciego , Fumar , Grado de Desobstrucción Vascular
10.
Am Heart J ; 205: 77-86, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30196181

RESUMEN

BACKGROUND: Whether high on-aspirin platelet reactivity (HAPR) confers an increased risk of adverse outcomes after percutaneous coronary intervention (PCI) remains unclear. We sought to examine the specific relationship between HAPR and clinical outcomes in ADAPT-DES. METHODS: A total of 8,526 "all-comer" patients in the ADAPT-DES registry who underwent placement of drug-eluting stents (DES) and were treated with aspirin and clopidogrel were assessed to measure platelet reactivity. HAPR was characterized as ≥550 aspirin reaction units and high on-clopidogrel platelet reactivity as >208 P2Y12 reaction units. Univariable and propensity-adjusted multivariable analyses were used to assess the relationship between HAPR and clinical outcomes. RESULTS: HAPR was present in 478 (5.6%) patients. Patients with HAPR were older and had more comorbid illnesses and more complex coronary anatomy. During 2-year follow-up, HAPR was not associated with increased rates of major adverse cardiac events (MACE), stent thrombosis, myocardial infarction, or all-cause mortality. In propensity-adjusted multivariable analyses, HAPR was not an independent predictor of MACE after successful PCI (multivariable adjusted hazard ratio: 1.04; 95% CI 0.64-1.69, P = .87). Nor was HAPR associated with reduced bleeding. Even among patients with concomitant high on-clopidogrel platelet reactivity, HAPR was not associated with worse ischemic outcomes (adjusted hazard ratio for 2-year MACE: 1.06; 95% CI 0.55-2.00, P = .87). CONCLUSIONS: HAPR was infrequently present in a large registry of patients undergoing PCI. There was no clear relationship between HAPR and 2-year clinical outcomes. Investigations of antiplatelet regimens without aspirin after DES implantation are ongoing and should inform future management of patients undergoing PCI.


Asunto(s)
Clopidogrel/administración & dosificación , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/métodos , Activación Plaquetaria/efectos de los fármacos , Sistema de Registros , Anciano , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Relación Dosis-Respuesta a Droga , Femenino , Estudios de Seguimiento , Humanos , Inyecciones Intravenosas , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/administración & dosificación , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
11.
Catheter Cardiovasc Interv ; 87(7): 1231-41, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26397982

RESUMEN

OBJECTIVES: To examine the benefit of the Tryton dedicated side branch (SB) stent compared with provisional stenting in the treatment of complex bifurcation lesions involving large SBs. BACKGROUND: The TRYTON Trial was designed to evaluate the utility of a dedicated SB stent to treat true bifurcation lesions involving large (≥2.5 mm by visual estimation) SBs. Patient enrolled in the trial had smaller SB diameters than intended (59% SB ≤2.25 mm by Core Lab QCA). The TRYTON Trial did not meet its primary endpoint due to an increased rate of peri-procedural myocardial infarctions (MIs). METHODS: The TRYTON Trial randomized 704 patients to the Tryton SB stent with main vessel DES versus provisional SB treatment with main vessel DES. The rates of the primary end point of target vessel failure and the secondary powered end point of angiographic percent diameter stenosis in the SB at 9 months were assessed and compared between the two treatment strategies among patients with a SB ≥2.25 mm diameter at baseline determined by Core Lab QCA. RESULTS: Among the 704 patients enrolled in the TRYTON Trial, 289 patients (143 provisional and 146 Tryton stent; 41% of entire cohort) had a SB ≥2.25 mm. The primary end point of TVF was numerically lower in the Tryton group compared with the provisional group (11.3% vs. 15.6%, P = 0.38), and was within the non-inferiority margin. No difference among the rates of clinically driven target vessel revascularization (3.5% vs. 4.3% P = 0.77) or cardiac death (0% both groups) were seen. In-segment percent diameter stenosis of the SB was significantly lower in the Tryton group compared with the provisional group (30.4% vs. 40.6%, P = 0.004). CONCLUSIONS: Analysis of the TRYTON Trial cohort of SB ≥2.25 mm supports the safety and efficacy of the Tryton SB stent compared with a provisional stenting strategy in the treatment of bifurcation lesions involving large SBs. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/terapia , Stents , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Trombosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento
12.
Circulation ; 129(4): 463-70, 2014 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-24281330

RESUMEN

BACKGROUND: Prior small to modest-sized studies suggest a benefit of intravascular ultrasound (IVUS) guidance in noncomplex lesions. Whether IVUS guidance is associated with improved clinical outcomes after drug-eluting stent (DES) implantation in an unrestricted patient population is unknown. METHODS AND RESULTS: Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents (ADAPT-DES) was a prospective, multicenter, nonrandomized "all-comers" study of 8583 consecutive patients at 11 international centers designed to determine the frequency, timing, and correlates of stent thrombosis and adverse clinical events after DES. Propensity-adjusted multivariable analysis was performed to examine the relationship between IVUS guidance and 1-year outcomes. IVUS was utilized in 3349 patients (39%), and larger-diameter devices, longer stents, and/or higher inflation pressures were used in 74% of IVUS-guided cases. IVUS guidance compared with angiography guidance was associated with reduced 1-year rates of definite/probable stent thrombosis (0.6% [18 events] versus 1.0% [53 events]; adjusted hazard radio, 0.40; 95% confidence interval, 0.21-0.73; P=0.003), myocardial infarction (2.5% versus 3.7%; adjusted hazard radio, 0.66; 95% confidence interval, 0.49-0.88; P=0.004), and composite adjudicated major adverse cardiac events (ie, cardiac death, myocardial infarction, or stent thrombosis) (3.1% versus 4.7%; adjusted hazard radio, 0.70; 95% confidence interval, 0.55-0.88; P=0.002). The benefits of IVUS were especially evident in patients with acute coronary syndromes and complex lesions, although significant reductions in major adverse cardiac events were present in all patient subgroups those with including stable angina and single-vessel disease. CONCLUSIONS: In ADAPT-DES, the largest study of IVUS use to date, IVUS guidance was associated with a reduction in stent thrombosis, myocardial infarction, and major adverse cardiac events within 1 year after DES implantation. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00638794.


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/métodos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Ultrasonografía Intervencional , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Análisis Multivariante , Infarto del Miocardio/epidemiología , Estudios Prospectivos , Factores de Riesgo , Trombosis/epidemiología , Resultado del Tratamiento
13.
Catheter Cardiovasc Interv ; 86 Suppl 1: S51-7, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25512256

RESUMEN

OBJECTIVES: We sought to evaluate the feasibility and safety of catheter-based supersaturated oxygen (SSO2 ) delivery via the left main coronary artery (LMCA) following primary percutaneous coronary intervention (PCI). BACKGROUND: In the multicenter, randomized AMIHOT-II trial, SSO2 delivered into the proximal or mid left anterior descending (LAD) artery via an indwelling intracoronary infusion catheter in patients with acute anterior ST-segment elevation myocardial infarction (STEMI) following primary PCI significantly reduced infarct size but resulted in a numerically higher incidence of safety events. METHODS: Patients with acute anterior STEMI presenting within 6 hr of symptom onset were enrolled at three centers. Following successful LAD stenting, SSO2 was infused into the LMCA via a diagnostic catheter for 60 min. The primary safety endpoint was the 30-day rate of target vessel failure (composite of death, reinfarction, or target vessel revascularization). Cardiac magnetic resonance imaging (cMRI) was performed at 3-5 and 30 days to assess infarct size. RESULTS: Twenty patients with acute anterior STEMI were enrolled. The infarct lesion was located in the proximal LAD in 7 cases (35%) and the mid LAD in 13 cases (65%). Following primary PCI, SSO2 was delivered successfully in all cases. Target vessel failure within 30 days occurred in 1 patient (5%). Median [interquartile range] infarct size was 13.7% [5.4-20.6%] at 3-5 days and 9.6% [2.1-14.5%] at 30 days. CONCLUSIONS: Following primary PCI in acute anterior STEMI, infusion of SSO2 via the LMCA is feasible, and is associated with a favorable early safety and efficacy profile.


Asunto(s)
Electrocardiografía , Infarto del Miocardio/terapia , Oxígeno/administración & dosificación , Cateterismo Cardíaco , Angiografía Coronaria , Vasos Coronarios , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Inyecciones Intraarteriales , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Intervención Coronaria Percutánea , Resultado del Tratamiento
14.
Lancet ; 382(9892): 614-23, 2013 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-23890998

RESUMEN

BACKGROUND: The relation between platelet reactivity and stent thrombosis, major bleeding, and other adverse events after coronary artery implantation of drug-eluting stents has been incompletely characterised. We aimed to determine the relation between platelet reactivity during dual therapy with aspirin and clopidogrel and clinical outcomes after successful coronary drug-eluting stent implantation. METHODS: ADAPT-DES was a prospective, multicentre registry of patients successfully treated with one or more drug-eluting stents and given aspirin and clopidogrel at 10-15 US and European hospitals. We assessed platelet reactivity in those patients after successful percutaneous coronary intervention using VerifyNow point-of-care assays, and assigned different cutoffs to define high platelet reactivity. The primary endpoint was definite or probable stent thrombosis; other endpoints were all-cause mortality, myocardial infarction, and clinically relevant bleeding. We did a propensity-adjusted multivariable analysis to determine the relation between platelet reactivity and subsequent adverse events. This study is registered with ClinicalTrials.gov, number NCT00638794. FINDINGS: Between Jan 7, 2008, and Sept 16, 2010, 8665 patients were prospectively enrolled at 11 sites, of which 8583 were eligible. At 1-year follow-up, stent thrombosis had occurred in 70 (0·8%) patients, myocardial infarction in 269 (3·1%), clinically relevant bleeding in 531 (6·2%), and death in 161 (1·9%) patients. High platelet reactivity on clopidogrel was strongly related to stent thrombosis (adjusted HR 2·49 [95% CI 1·43-4·31], p=0·001) and myocardial infarction (adjusted HR 1·42 [1·09-1·86], p=0·01), was inversely related to bleeding (adjusted HR 0·73 [0·61-0·89], p=0·002), but was not related to mortality (adjusted HR 1·20 [0·85-1·70], p=0·30). High platelet reactivity on aspirin was not significantly associated with stent thrombosis (adjusted HR 1·46 [0·58-3·64], p=0·42), myocardial infarction, or death, but was inversely related to bleeding (adjusted HR 0·65 [0·43-0·99], p=0·04). INTERPRETATION: The findings from this study emphasise the counter-balancing effects of haemorrhagic and ischaemic complications after stent implantation, and suggest that safer drugs or tailored strategies for the use of more potent agents must be developed if the benefits of greater platelet inhibition in patients with cardiovascular disease are to be realised. FUNDING: Boston Scientific, Abbott Vascular, Medtronic, Cordis, Biosensors, The Medicines Company, Daiichi-Sankyo, Eli Lilly, Volcano, and Accumetrics.


Asunto(s)
Enfermedad Coronaria/cirugía , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Agregación Plaquetaria/efectos de los fármacos , Aspirina/uso terapéutico , Pruebas de Coagulación Sanguínea , Clopidogrel , Enfermedad Coronaria/tratamiento farmacológico , Estenosis Coronaria/etiología , Estenosis Coronaria/prevención & control , Stents Liberadores de Fármacos/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Sistemas de Atención de Punto , Estudios Prospectivos , Sistema de Registros , Factores de Riesgo , Ticlopidina/análogos & derivados , Ticlopidina/uso terapéutico , Factores de Tiempo , Resultado del Tratamiento
15.
J Soc Cardiovasc Angiogr Interv ; 3(6): 102049, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39132596

RESUMEN

Background: Despite advances in therapy options, pulmonary embolism (PE) continues to carry a high risk of mortality and morbidity. Currently, therapeutic options are limited with only 2 US Food and Drug Administration-cleared catheter-based embolectomy devices approved for the treatment of intermediate-risk PE. The novel Helo PE thrombectomy catheter (Endovascular Engineering, Inc) has a flexible and collapsible funnel with an internal agitator for a dual mechanism of treatment for acute PE. We sought to investigate the safety and feasibility of the novel Helo PE thrombectomy catheter in intermediate-risk PE. Methods: A prospective, single-arm feasibility study evaluating the Helo PE catheter was performed in patients presenting with intermediate-risk PE. Patients underwent preprocedural and postprocedural computed tomography angiography. Primary efficacy was the difference in preprocedural to postprocedural right ventricle/left ventricle (RV/LV) ratio. Primary and secondary safety outcomes were all-cause mortality, major life-threatening bleeding, device-related serious adverse events, pulmonary or cardiac injury, and clinical decompensation at 48 hours postprocedure and at 30 days. Results: A total of 25 patients from 8 centers were consented and included in the analysis. Preprocedural computed tomography angiography revealed an RV/LV ratio of 1.53 ± 0.27. All patients underwent a successful thrombectomy procedure. Postprocedure, the RV/LV ratio was reduced to 1.15 ± 0.18, translating into a 23.2 ± 12.81% decrease from baseline. No patients underwent adjunctive thrombolysis. Two patients had adjunctive catheter-directed embolectomy with an alternative device. Two patients had postprocedural anemia requiring transfusion but did not meet criteria for major life-threatening bleeding by VARC-2 criteria. There were no major adverse events including no deaths, major bleeding, pulmonary injury, or vascular complications at 48 hours or 30 days post procedure. Conclusions: In this multicenter first-in-human study, use of the Helo PE thrombectomy catheter was feasible and safe for the treatment of acute PE.

17.
Catheter Cardiovasc Interv ; 82(3): 352-9, 2013 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-22927100

RESUMEN

BACKGROUND: The provisional approach for bifurcation stenting with side-branch balloon angioplasty is associated with dissections and suboptimal results requiring kissing balloon techniques or bailout stenting. We hypothesized that using a scoring balloon for the side branch and a drug-eluting stent for the main vessel might improve outcomes of true bifurcation lesions. METHODS AND RESULTS: A total of 93 patients with complex bifurcations were enrolled in a multicenter, single-arm, prospective clinical trial. A drug-eluting stent was deployed in the main vessel following dilatation of the side-branch stenosis with a scoring balloon. The overall angiographic success rate was 93.5%, and procedural success rate was 91.4%. The final diameter stenosis was 13.9% ± 7.2% for the main vessel and 33.3% ± 22.9% for the side branch. Crossover to stent deployment in the side branch was required in 10.8%. The postscoring balloon dissection rate was 8.2% and 6% (all ≤ class C) for the main vessel and side branch respectively, which was reduced to 1.1 and 2.1% poststenting. At 9-month follow-up, the composite MACE rate [cardiac death, myocardial infarction, or target lesion revascularization (TLR)] was 5.4%, including a TLR rate of 3.3% (1.1% from hospital discharge to 9 months). CONCLUSION: The 9-month results of the AGILITY trial support a simple provisional strategy for treating complex true bifurcation lesions with deployment of a drug-eluting stent in the main vessel after dilatation of the side-branch vessel with a scoring balloon. This strategy was associated with excellent and safe procedural results, a low rate of crossover to side-branch stenting, and favorable outcomes.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Estenosis Coronaria/terapia , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Angiografía Coronaria , Estenosis Coronaria/diagnóstico , Estenosis Coronaria/mortalidad , Trombosis Coronaria/etiología , Stents Liberadores de Fármacos , Diseño de Equipo , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Estudios Prospectivos , Sistema de Registros , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
18.
Circ Cardiovasc Interv ; 16(2): e012433, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36802804

RESUMEN

BACKGROUND: Poor myocardial reperfusion due to distal embolization and microvascular obstruction after percutaneous coronary intervention is associated with increased risk of morbidity and mortality. Prior trials have not shown a clear benefit of routine manual aspiration thrombectomy. Sustained mechanical aspiration may mitigate this risk and improve outcomes. The objective of this study is to evaluate sustained mechanical aspiration thrombectomy before percutaneous coronary intervention in high thrombus burden acute coronary syndrome patients. METHODS: This prospective study evaluated the Indigo CAT RX Aspiration System (Penumbra Inc, Alameda CA) for sustained mechanical aspiration thrombectomy before percutaneous coronary intervention at 25 hospitals across the USA. Adults presenting within 12 hours of symptom onset with high thrombus burden and target lesion(s) located in a native coronary artery were eligible. The primary end point was a composite of cardiovascular death, recurrent myocardial infarction, cardiogenic shock, or new or worsening New York Heart Association class IV heart failure within 30 days. Secondary end points included Thrombolysis in Myocardial Infarction thrombus grade, Thrombolysis in Myocardial Infarction flow, myocardial blush grade, stroke, and device-related serious adverse events. RESULTS: From August 2019 through December 2020, a total of 400 patients were enrolled (mean age 60.4 years, 76.25% male). The primary composite end point rate was 3.60% (14/389 [95% CI, 2.0-6.0%]). Rate of stroke within 30 days was 0.77%. Final rates of Thrombolysis in Myocardial Infarction thrombus grade 0, Thrombolysis in Myocardial Infarction flow 3, and myocardial blush grade 3 were 99.50%, 97.50%, and 99.75%, respectively. No device-related serious adverse events occurred. CONCLUSIONS: Sustained mechanical aspiration before percutaneous coronary intervention in high thrombus burden acute coronary syndrome patients was safe and was associated with high rates of thrombus removal, flow restoration, and normal myocardial perfusion on final angiography.


Asunto(s)
Acinonyx , Síndrome Coronario Agudo , Oclusión Coronaria , Trombosis Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Accidente Cerebrovascular , Trombosis , Masculino , Animales , Femenino , Vasos Coronarios/diagnóstico por imagen , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/terapia , Síndrome Coronario Agudo/complicaciones , Succión , Estudios Prospectivos , Resultado del Tratamiento , Trombosis/etiología , Trombectomía/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Oclusión Coronaria/etiología , Accidente Cerebrovascular/etiología , Trombosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/terapia , Angiografía Coronaria
19.
J Am Coll Cardiol ; 82(3): 183-195, 2023 07 18.
Artículo en Inglés | MEDLINE | ID: mdl-37207924

RESUMEN

BACKGROUND: Bioresorbable vascular scaffolds (BVS) were designed to improve late event-free survival compared with metallic drug-eluting stents. However, initial trials demonstrated worse early outcomes with BVS, in part due to suboptimal technique. In the large-scale, blinded ABSORB IV trial, polymeric everolimus-eluting BVS implanted with improved technique demonstrated noninferior 1-year outcomes compared with cobalt chromium everolimus-eluting stents (CoCr-EES). OBJECTIVES: This study sought to evaluate the long-term outcomes from the ABSORB IV trial. METHODS: We randomized 2,604 patients at 147 sites with stable or acute coronary syndromes to BVS with improved technique vs CoCr-EES. Patients, clinical assessors, and event adjudicators were blinded to randomization. Five-year follow-up was completed. RESULTS: Target lesion failure at 5 years occurred in 216 (17.5%) patients assigned to BVS and 180 (14.5%) patients assigned to CoCr-EES (P = 0.03). Device thrombosis within 5 years occurred in 21 (1.7%) BVS and 13 (1.1%) CoCr-EES patients (P = 0.15). Event rates were slightly greater with BVS than CoCr-EES through 3-year follow-up and were similar between 3 and 5 years. Angina, also centrally adjudicated, recurred within 5 years in 659 patients (cumulative rate 53.0%) assigned to BVS and 674 (53.3%) patients assigned to CoCr-EES (P = 0.63). CONCLUSIONS: In this large-scale, blinded randomized trial, despite the improved implantation technique, the absolute 5-year rate of target lesion failure was 3% greater after BVS compared with CoCr-EES. The risk period for increased events was limited to 3 years, the time point of complete scaffold bioresorption; event rates were similar thereafter. Angina recurrence after intervention was frequent during 5-year follow-up but was comparable with both devices.(Absorb IV Randomized Controlled Trial; NCT02173379).


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Implantes Absorbibles , Everolimus , Diseño de Prótesis , Stents , Andamios del Tejido , Resultado del Tratamiento
20.
J Am Heart Assoc ; 12(1): e026482, 2023 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-36565189

RESUMEN

Background Diabetes mellitus and high platelet reactivity (HPR) on clopidogrel are both associated with increased risk of ischemic events after percutaneous coronary intervention, but whether the HPR-associated risk of adverse ischemic events differs by diabetes mellitus status is unknown. Methods and Results ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a prospective, multicenter registry of patients treated with coronary drug-eluting stents. HPR was defined as P2Y12 reaction units >208 by the VerifyNow point-of-care assay. Cox multivariable analysis was used to assess whether HPR-associated risk of major adverse cardiac events (MACE; cardiac death, myocardial infarction, or stent thrombosis) varied for patients with insulin-treated diabetes mellitus (ITDM), non-ITDM, and no diabetes mellitus. Diabetes mellitus and HPR were included in an interaction analysis. Of 8582 patients enrolled, 2429 (28.3%) had diabetes mellitus, of whom 998 (41.1%) had ITDM. Mean P2Y12 reaction units were higher in patients with diabetes mellitus versus without diabetes mellitus, and HPR was more frequent in patients with diabetes mellitus. HPR was associated with consistently increased 2-year rates of MACE in patients with and without diabetes mellitus (Pinteraction=0.36). A significant interaction was present between HPR and non-insulin-treated diabetes mellitus versus ITDM for 2-year MACE (adjusted hazard ratio [HR] for non-ITDM, 2.28 [95% CI, 1.39-3.73] versus adjusted HR for ITDM, 1.02 [95% CI, 0.70-1.50]; Pinteraction=0.01). Conclusions HPR was more common in patients with diabetes mellitus and was associated with an increased risk of MACE in both patients with and without diabetes mellitus. In patients with diabetes mellitus, a more pronounced effect of HPR on MACE was present in lower-risk non-ITDM patients than in higher-risk patients with ITDM. Registration URL: https://clinicaltrials.gov/ct2/show/NCT00638794; Unique identifier: NCT00638794. ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents).


Asunto(s)
Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Intervención Coronaria Percutánea , Humanos , Inhibidores de Agregación Plaquetaria/efectos adversos , Estudios Prospectivos , Factores de Riesgo , Plaquetas , Clopidogrel/uso terapéutico , Clopidogrel/farmacología , Isquemia/etiología , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/complicaciones , Diabetes Mellitus/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA