Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Eur J Nucl Med Mol Imaging ; 46(3): 623-637, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30564849

RESUMEN

PURPOSE: Sentinel lymph node biopsy is an essential staging tool in patients with clinically localized oral cavity squamous cell carcinoma. The harvesting of a sentinel lymph node entails a sequence of procedures with participation of specialists in nuclear medicine, radiology, surgery, and pathology. The aim of this document is to provide guidelines for nuclear medicine physicians performing lymphoscintigraphy for sentinel lymph node detection in patients with early N0 oral cavity squamous cell carcinoma. METHODS: These practice guidelines were written and have been approved by the European Association of Nuclear Medicine (EANM) and the International Atomic Energy Agency (IAEA) to promote high-quality lymphoscintigraphy. The final result has been discussed by distinguished experts from the EANM Oncology Committee, and national nuclear medicine societies. The document has been endorsed by the Society of Nuclear Medicine and Molecular Imaging (SNMMI). These guidelines, together with another two focused on Surgery and Pathology (and published in specialised journals), are part of the synergistic efforts developed in preparation for the "2018 Sentinel Node Biopsy in Head and Neck Consensus Conference". CONCLUSION: The present practice guidelines will help nuclear medicine practitioners play their essential role in providing high-quality lymphatic mapping for the care of early N0 oral cavity squamous cell carcinoma patients.


Asunto(s)
Carcinoma de Células Escamosas/patología , Neoplasias de la Boca/patología , Medicina Nuclear , Guías de Práctica Clínica como Asunto , Biopsia del Ganglio Linfático Centinela/métodos , Carcinoma de Células Escamosas/diagnóstico por imagen , Europa (Continente) , Humanos , Procesamiento de Imagen Asistido por Computador , Neoplasias de la Boca/diagnóstico por imagen , Estadificación de Neoplasias , Tomografía Computarizada por Tomografía de Emisión de Positrones , Protección Radiológica
2.
Semin Nucl Med ; 48(3): 299-306, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29626946

RESUMEN

The International Atomic Energy Agency (IAEA) developed a comprehensive program-Quality Management Audits in Nuclear Medicine (QUANUM). This program covers all aspects of nuclear medicine practices including, but not limited to, clinical practice, management, operations, and services. The QUANUM program, which includes quality standards detailed in relevant checklists, aims at introducing a culture of comprehensive quality audit processes that are patient oriented, systematic, and outcome based. This paper will focus on the impact of the implementation of QUANUM on daily routine practices in audited centers. Thirty-seven centers, which had been externally audited by experts under IAEA auspices at least 1 year earlier, were invited to run an internal audit using the QUANUM checklists. The external audits also served as training in quality management and the use of QUANUM for the local teams, which were responsible of conducting the internal audits. Twenty-five out of the 37 centers provided their internal audit report, which was compared with the previous external audit. The program requires that auditors score each requirement within the QUANUM checklists on a scale of 0-4, where 0-2 means nonconformance and 3-4 means conformance to international regulations and standards on which QUANUM is based. Our analysis covering both general and clinical areas assessed changes on the conformance status on a binary manner and the level of conformance scores. Statistical analysis was performed using nonparametric statistical tests. The evaluation of the general checklists showed a global improvement on both the status and the levels of conformances (P < 0.01). The evaluation of the requirements by checklist also showed a significant improvement in all, with the exception of Hormones and Tumor marker determinations, where changes were not significant. Of the 25 evaluated institutions, 88% (22 of 25) and 92% (23 of 25) improved their status and levels of conformance, respectively. Fifty-five requirements, on average, increased from nonconformance to conformance status. In 8 key areas, the number of improved requirements was well above the average: Administration & Management (checklist 2); Radiation Protection & Safety (checklist 4); General Quality Assurance system (checklist 6); Imaging Equipment Quality Assurance or Quality Control (checklist 7); General Diagnostic (checklist 9); General Therapeutic (checklist 12); Radiopharmacy Level 1 (checklist 14); and Radiopharmacy Level 2 (checklist 15). Analysis of results related to clinical activities showed an overall positive impact on both the status and the level of conformance to international standards. Similar results were obtained for the most frequently performed clinical imaging and therapeutic procedures. Our study shows that the implementation of a comprehensive quality management system through the IAEA QUANUM program has a positive impact on nuclear medicine practices.


Asunto(s)
Auditoría Clínica , Medicina Nuclear , Evaluación de Resultado en la Atención de Salud , Control de Calidad
3.
Semin Nucl Med ; 47(6): 680-686, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28969766

RESUMEN

An effective management system that integrates quality management is essential for a modern nuclear medicine practice. The Nuclear Medicine and Diagnostic Imaging Section of the International Atomic Energy Agency (IAEA) has the mission of supporting nuclear medicine practice in low- and middle-income countries and of helping them introduce it in their health-care system, when not yet present. The experience gathered over several years has shown diversified levels of development and varying degrees of quality of practice, among others because of limited professional networking and limited or no opportunities for exchange of experiences. Those findings triggered the development of a program named Quality Management Audits in Nuclear Medicine (QUANUM), aimed at improving the standards of NM practice in low- and middle-income countries to internationally accepted standards through the introduction of a culture of quality management and systematic auditing programs. QUANUM takes into account the diversity of nuclear medicine services around the world and multidisciplinary contributions to the practice. Those contributions include clinical, technical, radiopharmaceutical, and medical physics procedures. Aspects of radiation safety and patient protection are also integral to the process. Such an approach ensures consistency in providing safe services of superior quality to patients. The level of conformance is assessed using standards based on publications of the IAEA and the International Commission on Radiological Protection, and guidelines from scientific societies such as Society of Nuclear Medicine and Molecular Imaging (SNMMI) and European Association of Nuclear Medicine (EANM). Following QUANUM guidelines and by means of a specific assessment tool developed by the IAEA, auditors, both internal and external, will be able to evaluate the level of conformance. Nonconformances will then be prioritized and recommendations will be provided during an exit briefing. The same tool could then be applied to assess any improvement after corrective actions are taken. This is the first comprehensive audit program in nuclear medicine that helps evaluate managerial aspects, safety of patients and workers, clinical practice, and radiopharmacy, and, above all, keeps them under control all together, with the intention of continuous improvement.


Asunto(s)
Auditoría Administrativa , Energía Nuclear , Medicina Nuclear/normas , Cintigrafía , Humanos , Agencias Internacionales
4.
Semin Nucl Med ; 47(6): 687-693, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28969767

RESUMEN

The International Atomic Energy Agency has developed a program, named Quality Management Audits in Nuclear Medicine (QUANUM), to help its Member States to check the status of their nuclear medicine practices and their adherence to international reference standards, covering all aspects of nuclear medicine, including quality assurance/quality control of instrumentation, radiopharmacy (further subdivided into levels 1, 2, and 3, according to complexity of work), radiation safety, clinical applications, as well as managerial aspects. The QUANUM program is based on both internal and external audits and, with specifically developed Excel spreadsheets, it helps assess the level of conformance (LoC) to those previously defined quality standards. According to their level of implementation, the level of conformance to requested standards; 0 (absent) up to 4 (full conformance). Items scored 0, 1, and 2 are considered non-conformance; items scored 3 and 4 are considered conformance. To assess results of the audit missions performed worldwide over the last 8 years, a retrospective analysis has been run on reports from a total of 42 audit missions in 39 centers, three of which had been re-audited. The analysis of all audit reports has shown an overall LoC of 73.9 ± 8.3% (mean ± standard deviation), ranging between 56.6% and 87.9%. The highest LoC has been found in the area of clinical services (83.7% for imaging and 87.9% for therapy), whereas the lowest levels have been found for Radiopharmacy Level 2 (56.6%); Computer Systems and Data Handling (66.6%); and Evaluation of the Quality Management System (67.6%). Prioritization of non-conformances produced a total of 1687 recommendations in the final audit report. Depending on the impact on safety and daily clinical activities, they were further classified as critical (requiring immediate action; n = 276; 16% of the total); major (requiring action in relatively short time, typically from 3 to 6 months; n = 604; 36%); whereas the remaining 807 (48%) were classified as minor, that is, to be addressed whenever possible. The greatest proportion of recommendations has been found in the category "Managerial, Organization and Documentation" (26%); "Staff Radiation Protection and Safety" (17.3%); "Radiopharmaceuticals Preparation, Dispensing and Handling" (15.8%); and "Quality Assurance/Quality Control" and "Management of Equipment and Software" (11.4%). The lowest level of recommendations belongs to the item "Human Resources" (4%). The QUANUM program proved applicable to a wide variety of institutions, from small practices to larger centers with PET/CT and cyclotrons. Clinical services rendered to patients showed a good compliance with international standards, whereas issues related to radiation protection of both staff and patients will require a higher degree of attention. This is a relevant feedback for the International Atomic Energy Agency with regard to the effective translation of safety recommendations into routine practice. Training on drafting and application of standard operating procedures should also be considered a priority.


Asunto(s)
Auditoría Administrativa , Energía Nuclear , Medicina Nuclear/normas , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA