Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Front Neurosci ; 15: 613844, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33790731

RESUMEN

Sieve electrodes stand poised to deliver the selectivity required for driving advanced prosthetics but are considered inherently invasive and lack the stability required for a chronic solution. This proof of concept experiment investigates the potential for the housing and engagement of a sieve electrode within the medullary canal as part of an osseointegrated neural interface (ONI) for greater selectivity toward improving prosthetic control. The working hypotheses are that (A) the addition of a sieve interface to a cuff electrode housed within the medullary canal of the femur as part of an ONI would be capable of measuring efferent and afferent compound nerve action potentials (CNAPs) through a greater number of channels; (B) that signaling improves over time; and (C) that stimulation at this interface generates measurable cortical somatosensory evoked potentials through a greater number of channels. The modified ONI was tested in a rabbit (n = 1) amputation model over 12 weeks, comparing the sieve component to the cuff, and subsequently compared to historical data. Efferent CNAPs were successfully recorded from the sieve demonstrating physiological improvements in CNAPs between weeks 3 and 5, and somatosensory cortical responses recorded at 12 weeks postoperatively. This demonstrates that sieve electrodes can be housed and function within the medullary canal, demonstrated by improved nerve engagement and distinct cortical sensory feedback. This data presents the conceptual framework for housing more sophisticated sieve electrodes in bone as part of an ONI for improving selectivity with percutaneous connectivity toward improved prosthetic control.

2.
Mil Med ; 185(Suppl 1): 462-469, 2020 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-32074371

RESUMEN

INTRODUCTION: While debate persists over how to best prevent or treat amputation neuromas, the more pressing question of how to best marry residual nerves to state-of-the-art robotic prostheses for naturalistic control of a replacement limb has come to the fore. One potential solution involves the transposition of terminal nerve ends into the medullary canal of long bones, creating the neural interface within the bone. Nerve transposition into bone is a long-practiced, clinically relevant treatment for painful neuromas. Despite neuropathic pain relief, the physiological capacity of transposed nerves to conduct motor and sensory signals required for prosthesis control remains unknown. This pilot study addresses the hypotheses that (1) bone provides stability to transposed nerves and (2) nerves transposed into bone remain physiologically active, as they relate to the creation of an osseointegrated neural interface. METHODS: New Zealand white rabbits received transfemoral amputation, with the sciatic nerve transposed into the femur. RESULTS: Morphological examination demonstrates that nerves remain stable within the medullary canal, while compound nerve action potentials evoked by electrical stimulation of the residual nerve within the bone could be achieved at 12 weeks (p < 0.0005). CONCLUSION: Transposed nerves retain a degree of physiological function suitable for creating an osseointegrated neural interface.


Asunto(s)
Prótesis Anclada al Hueso/veterinaria , Red Nerviosa/fisiopatología , Conducción Nerviosa/fisiología , Prótesis e Implantes/veterinaria , Potenciales de Acción , Animales , Proyectos Piloto , Conejos/lesiones , Robótica/métodos , Robótica/tendencias
3.
J Neurosci Methods ; 331: 108504, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-31711884

RESUMEN

BACKGROUND: Chronic stability and high degrees of selectivity are both essential but somewhat juxtaposed components for creating an implantable bi-directional PNI capable of controlling of a prosthetic limb. While the more invasive implantable electrode arrays provide greater specificity, they are less stable over time due to compliance mismatch with the dynamic soft tissue environment in which the interface is created. NEW METHOD: This paper takes the surgical approach of transposing nerves into bone to create neural interface within the medullary canal of long bones, an osseointegrated neural interface, to provide greater stability for implantable electrodes. In this context, we describe the surgical model for transfemoral amputation with transposition of the sciatic nerve into the medullary canal in rabbits. We investigate the capacity to create a neural interface within the medullary canal histolomorphologically. In a separate proof of concept experiment, we quantify the chronic physiological capacity of transposed nerves to conduct compound nerve action potentials evoked via an Osseointegrated Neural Interface. COMPARISON WITH EXISTING METHOD(S): The rabbit serves as an important animal model for both amputation neuroma and osseointegration research, but is underutilized for the exploration neural interfacing in an amputation setting. RESULTS: Our findings demonstrate that transposed nerves remain stable over 12 weeks. Creating a neural interface within the medullary canal is possible and does not impede nerve regeneration or physiological capacity. CONCLUSIONS: This article represents the first evidence that an Osseointegrated Neural Interface can be surgically created, capable of chronic stimulation/recording from amputated nerves required for future prosthetic control.


Asunto(s)
Amputados , Miembros Artificiales , Animales , Electrodos Implantados , Humanos , Regeneración Nerviosa , Oseointegración , Diseño de Prótesis , Conejos
4.
J Neurosci Methods ; 336: 108602, 2020 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-31981569

RESUMEN

BACKGROUND: A number of peripheral nerve interfaces for nerve stimulation and recording exist for the purpose of controlling neural prostheses, each with a set of advantages and disadvantages. The ultimate goal of neural prostheses is a seamless bi-directional communication between the peripheral nervous system and the prosthesis. Here, we developed an interfacing electrode array, the "cuff and sieve electrodes" (CASE), integrating microfabricated cuff and sieve electrodes to a single unit, to decrease the weaknesses faced by these electrode designs in isolation. This paper presents the design and fabrication of CASE with ex vivo and in vivo testing towards chronic application. METHODS: Electroplating on electrode sites was performed to improve electrical properties of CASE. The surface morphology and chemical compound were characterized using scanning electron microscopy and energy-dispersive spectroscopy, respectively. Electrochemical impedance spectroscopy and cyclic voltammetry were performed to evaluate the electrical properties of CASE and determine viability for in vivo applications. Terminal CASE implantations were performed in a rat sciatic transection model to test the ease of implantation and capacity to write sensory information into the biological system. RESULTS: The modified platinum film resulted in reducing impedance magnitude (9.18 kΩ and 2.27 kΩ) and increasing phase angle (over 70°). CASE stimulation of the sciatic nerve at different amplitudes elicited significantly different cortical responses (p < 0.005) as demonstrated by somatosensory evoked potentials, recorded via micro-electrocorticography. CONCLUSIONS: The ability to elicit cortical responses from sciatic nerve stimulation demonstrates the proof of concept for both the implantation and chronic monitoring of CASE interfaces for innovative prosthetic control.


Asunto(s)
Miembros Artificiales , Prótesis Neurales , Animales , Impedancia Eléctrica , Estimulación Eléctrica , Electrodos , Electrodos Implantados , Nervios Periféricos , Ratas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA