RESUMEN
BACKGROUND: Stent implantation has become standard of care in older children and adults for treatment of branch pulmonary artery stenosis (BPAS) and coarctation aorta (CoAo). There are no stents approved or available for infants that have the potential to be dilated to adult diameters. The Minima stent was designed to fulfill this unmet need. METHODS: Multicenter, prospective, nonrandomized early feasibility study evaluating safety and effectiveness of the Minima stent for treatment of BPAS and CoAo. Primary endpoints included: (1) successful deployment across lesion, (2) stenosis relief defined by an increase in angiographic diameter of >50% and (3) freedom from stent explant, embolization or migration at 30 days and 6 months. RESULTS: Between 2/2022 and 5/2022, 10 pts underwent Minima stent implantation with a median age and weight of 9 months (4-43 months) and 7.6 kg (5.1-16.9 kg). Procedural success and predefined stenosis relief was achieved in all cases (CoAo [n = 4], BPAS [n = 6]). Adverse events occurred in 3 pts: transient diminished lower extremity pulse (n = 2), distal stent on-balloon displacement successfully managed in the catheterization suite (n = 1). There were no deaths or major adverse events. All patients were free from stent explant and migration at 30 days and 6 months with no evidence for significant restenosis at latest follow-up. CONCLUSIONS: Implantation of the Renata Minima stent was safe and effective for the treatment of BPAS and CoAo in this small cohort of infants and young children during early follow-up. Based on these early results, an expanded study with longer follow-up is warranted.
Asunto(s)
Coartación Aórtica , Estudios de Factibilidad , Diseño de Prótesis , Estenosis de Arteria Pulmonar , Stents , Humanos , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/terapia , Coartación Aórtica/fisiopatología , Lactante , Estudios Prospectivos , Masculino , Femenino , Resultado del Tratamiento , Estenosis de Arteria Pulmonar/diagnóstico por imagen , Estenosis de Arteria Pulmonar/fisiopatología , Estenosis de Arteria Pulmonar/terapia , Estenosis de Arteria Pulmonar/etiología , Factores de Tiempo , Preescolar , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/fisiopatología , Factores de Edad , Angioplastia de Balón/instrumentación , Angioplastia de Balón/efectos adversosRESUMEN
Therapies to support small infants in decompensated heart failure that are failing medical management are limited. We have used the hybrid approach, classically reserved for high-risk infants with single ventricle physiology, in patients with biventricular physiology with left ventricular failure. This approach secures systemic circulation, relieves left atrial hypertension, protects the pulmonary vasculature, and allows the right ventricle to support cardiac output. This approach can be used as a bridge to transplantation in select individuals. Infants without single ventricle congenital heart disease who were treated with the hybrid approach between 2008 and 2021 were included in analysis. Eight patients were identified. At the time of hybrid procedure, the median weight was 3.2 kg (range 2.4-3.6 kg) and the median age was 18 days (range 1-153 days). Seventy five percent were mechanically ventilated and 88% were on inotropic support. The median duration from hybrid procedure to transplant was 63 days (range 4-116 days). All patients experienced a good outcome (delisted for improvement or transplanted). The hybrid procedure is an appropriate therapeutic bridge to transplantation in a carefully selected subset of critically ill infants without single ventricle congenital heart disease in whom alternate therapies may confer increased risk for morbidity and mortality.
Asunto(s)
Cardiopatías Congénitas , Trasplante de Corazón , Síndrome del Corazón Izquierdo Hipoplásico , Lactante , Humanos , Resultado del Tratamiento , Ventrículos Cardíacos , Estudios RetrospectivosRESUMEN
BACKGROUND: The Harmony TPV25 transcatheter pulmonary valve (Medtronic Inc.) is constructed with a self-expanding stent frame comprising six zigged nitinol wires sewn together and covered with knitted polyester fabric, with flared inflow and outflow ends and a porcine pericardial valve sutured to the central portion of the device. It was approved for treatment of pulmonary regurgitation after prior right ventricular outflow tract repair in 2021. Early outcomes of this procedure have been excellent, but little is known about valve durability or ultimate mechanisms of dysfunction. METHODS: We collected data on patients who underwent reintervention for TPV25 dysfunction and described findings related to distortion of the stent frame and tissue accumulation. RESULTS: We describe six patients who underwent valve-in-valve implant for TPV25 obstruction (peak catheterization gradient peak 28-73 mmHg) 10-28 months after implant. In all cases, there was tissue accumulation within the inflow and valve-housing segments of the device and deformation of the self-expanding valve frame characterized by variable circumferential narrowing at the junction between the valve housing and the inflow and outflow portions of the device, with additional geometric changes in all segments. All six patients underwent valve-in-valve implant that results in a final peak gradient ≤10 mmHg and no regurgitation. DISCUSSION: The occurrence of short-term Harmony TPV25 dysfunction in multiple patients with a similar appearance of frame distortion and tissue accumulation within the inflow and valve housing portions of the device suggests that this may be an important failure mechanism for this valve. Potential causes of the observed findings are discussed. It is possible to treat this mechanism of TPV25 dysfunction with valve-in-valve implant using balloon expandable transcatheter valves.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Obstrucción del Flujo de Salida Ventricular Derecho , Obstrucción del Flujo Ventricular Externo , Humanos , Porcinos , Animales , Prótesis Valvulares Cardíacas/efectos adversos , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/cirugía , Resultado del Tratamiento , Cateterismo Cardíaco , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/cirugía , Stents/efectos adversos , Diseño de PrótesisRESUMEN
BACKGROUND: Pulmonary vein stenosis (PVS) is a rare pediatric condition associated with significant mortality and morbidity. PVS in patients following heart transplant (HT) has not yet been described. METHODS: Patients who had clinically significant PVS following a heart transplant during the time period of April 1, 2013 to April 30, 2023, at Seattle Children's Hospital were identified. Clinically significant PVS was defined as an atretic vein or a vein with a gradient of ≥4 mmHg across at least one vein by echocardiogram or during cardiac catheterization. Patients who had a diagnosis of PVS prior to their transplant were excluded. A total of six patients were identified. We collected clinical data on these patients from their pre-transplant course to their most recent status. RESULTS: The median age at HT was 7.5 months (range 2-13 months). The median time from HT to diagnosis of PVS was 3.5 months (range 0.3-13 months). At the last follow-up, the patients had had two to five pulmonary vein interventions, and there were no mortalities. The donor-to-recipient weight and total cardiac volume (TCV) ratios were less than 2.0 in five of six of the patients. CONCLUSIONS: PVS is a rare complication that is associated with patients who undergo HT during infancy. PVS develops soon after HT and screening should occur accordingly. Interestingly, high donor-to-recipient weight and TCV ratios are not necessarily associated with the development of PVS. Further work will need to be performed in order to determine the significance of PVS in post-HT patients.
RESUMEN
Kawasaki disease (KD) is an acute vasculitis that can cause coronary artery inflammation and aneurysm formation leading to early obstructive disease. We describe the use of PK Papyrus covered stents (Biotronic, Inc.) in three pediatric patients to exclude coronary artery aneurysms (CAA) from the circulation and relieve aneurysm associated stenoses. Follow-up angiography at 11-17 months postprocedure demonstrated persistent exclusion of CAA and varying degrees of in-stent restenosis (ISR). Two patients required percutaneous coronary intervention with drug eluting stent (DES) implantation to relieve in-stent stenosis. Our findings suggest that CAA exclusion with the PK Papyrus stent is possible and may be a valuable tool in simultaneously treating stenotic and thrombogenic CAA in pediatric KD patients. ISR of these non-DES remains an issue and may require additional interventions within the short-term to maintain vessel patency.
Asunto(s)
Aneurisma Coronario , Reestenosis Coronaria , Stents Liberadores de Fármacos , Síndrome Mucocutáneo Linfonodular , Intervención Coronaria Percutánea , Humanos , Niño , Síndrome Mucocutáneo Linfonodular/complicaciones , Síndrome Mucocutáneo Linfonodular/diagnóstico , Stents Liberadores de Fármacos/efectos adversos , Vasos Coronarios , Resultado del Tratamiento , Aneurisma Coronario/diagnóstico por imagen , Aneurisma Coronario/etiología , Aneurisma Coronario/terapia , Stents , Intervención Coronaria Percutánea/efectos adversos , Reestenosis Coronaria/etiología , Angiografía CoronariaRESUMEN
Determine outcomes of catheter intervention for aortic coarctation in infants. Aortic coarctation in infants following surgical repair and in high surgical risk native cases remains a challenging problem. Catheter intervention is an alternative to surgical intervention. Single-center, chart review of infants with biventricular anatomy who underwent coarctation stent placement or balloon angioplasty between 04/2004 and 04/2020. Outcomes of interest included change in aortic lumen diameter, peak gradient, number of re-interventions, time to re-intervention, and adverse events. Thirty-four patients were included in analysis, of those 16 underwent stent placement. Patients' mean age was 4.0 ± 3.0 months and weight of 5.3 ± 1.9 kg. Follow-up interval was 5.4 ± 5.1 years (0.2-16.1 years). Twelve (35%) patients underwent procedure due to ventricular dysfunction; the rest were for high resting gradient. Coarctation diameter increased from 2.4 ± 1.0 to 4.5 ± 1.3 (p < 0.01) and gradient decreased from 32.0 ± 18.4 mmHg to 9.2 ± 8.8 mmHg (p < 0.01). Thirteen (81%) of the stented patients required at least one re-intervention, at an average of 1.7 ± 3.2 years from the index procedure. Five (28%) of those undergoing balloon angioplasty required repeat intervention. There was no mortality due to the procedure and one late mortality. One patient had a serious procedural adverse event. On follow-up, 12 (35%) were on anti-hypertensive medications. Catheter intervention, including stent placement, for aortic coarctation in infants is feasible with an acceptable adverse event profile. Repeat interventions are common.
Asunto(s)
Angioplastia de Balón , Coartación Aórtica , Angioplastia de Balón/efectos adversos , Angioplastia de Balón/métodos , Antihipertensivos , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/cirugía , Estudios de Seguimiento , Humanos , Lactante , Recurrencia , Estudios Retrospectivos , Stents , Resultado del TratamientoRESUMEN
The Society for Cardiovascular Angiography and Interventions (SCAI) Think Tank is a collaborative venture that brings together interventional cardiologists, administrative partners, and select members of the cardiovascular industry community annually for high-level field-wide discussions. The 2021 Think Tank was organized into four parallel sessions reflective of the field of interventional cardiology: (a) coronary intervention, (b) endovascular medicine, (c) structural heart disease, and (d) congenital heart disease. Each session was moderated by a senior content expert and co-moderated by a member of SCAI's Emerging Leader Mentorship program. This document presents the proceedings to the wider cardiovascular community in order to enhance participation in this discussion, create additional dialog from a broader base, and thereby aid SCAI, the industry community and external stakeholders in developing specific action items to move these areas forward.
Asunto(s)
Cardiólogos , Cardiología , Cardiopatías Congénitas , Angiografía , Humanos , Resultado del TratamientoRESUMEN
Transcatheter closure of patent ductus arteriosus (PDA) in premature infants is a feasible, safe, and an effective alternative to surgical ligation and may be performed with an implant success rate of 97%. Major procedural complications related to transcatheter PDA closure in extremely low birth weight (ELBW) infants are relatively infrequent (< 3%) ,but may be associated with a fatality if not optimally managed. Operators performing transcatheter PDA closures should be knowledgeable about these potential complications and management options. Prompt recognition and treatment are often necessary to avoid serious consequences. With strict guidelines on operator training, proctoring requirements, and technical refinements, transcatheter PDA closure in ELBW infants can be performed safely with low complication rates. This article summarizes the consensus guidelines put forward by a panel of physicians for the prevention and management of periprocedural complications of transcatheter PDA closure with the Amplatzer Piccolo Occluder in ELBW infants.
Asunto(s)
Consenso , Conducto Arterioso Permeable/cirugía , Complicaciones Posoperatorias/prevención & control , Guías de Práctica Clínica como Asunto , Dispositivo Oclusor Septal/efectos adversos , Humanos , Lactante , Recien Nacido con Peso al Nacer Extremadamente BajoRESUMEN
OBJECTIVE: To assess the outcomes of the use of the percutaneous Impella RP device (Abiomed, Danvers, MA) in adolescents and young adults. BACKGROUND: Results of the Impella RP device have been reported in adults, but a multicenter experience in adolescents and young adults has yet to be reported. METHODS: Patients ≤21 years of age who underwent implantation of an Impella RP device for refractory right heart failure from June, 2016 to April, 2018 at nine U.S. Centers were included. RESULTS: A total of 12 adolescents, median age of 18 (14-21) years and median weight 74.4 (49-112.4) kg underwent Impella RP implantation (INTERMACS Profile 1 in nine and Profile 2 in three patients. The central venous pressure decreased from 20 (16-35) to 12 (7-17) mmHg, (p = .001). One patient was concomitantly supported with an intra-aortic balloon pump (IABP) and the rest with a percutaneous/surgically placed left ventricular assist device. There was one adverse event related to the Impella RP device (thrombosis requiring explant). The support duration was 6.5 days (4.8 hr-18.4 days) and survival to hospital discharge was 83%. At a median follow-up of 11 months (5 days-2.5 years), 8 of 12 (67%) patients are alive. CONCLUSIONS: In this multicenter experience, the Impella RP device was found to be efficacious and safe when used in adolescents and young adults. Further studies are warranted to identify suitable young/pediatric candidates for Impella RP therapy for right heart failure.
Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Hemodinámica , Implantación de Prótesis/instrumentación , Función Ventricular Derecha , Adolescente , Factores de Edad , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Mortalidad Hospitalaria , Humanos , Masculino , Diseño de Prótesis , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/mortalidad , Recuperación de la Función , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Adulto JovenRESUMEN
OBJECTIVES: Characterize the safety and effectiveness of the Amplatzer Piccolo Occluder for patent ductus arteriosus (PDA) closure. BACKGROUND: The presence of a hemodynamically significant PDA has been associated with an increased risk of morbidity and mortality in children born premature. METHODS: This was a single arm, prospective, multicenter, non-randomized study to evaluate the Amplatzer Piccolo Occluder to treat PDA in patients ≥700 g. From June 2017 to February 2019, 200 patients were enrolled at nine centers, with 100 patients weighing ≤2 kg. Primary effectiveness endpoint was the rate of PDA closure at 6-month follow-up. Primary safety endpoint was the rate of major complications through 6 months. Secondary endpoint was rate of significant pulmonary or aortic obstruction through 6 months' follow-up. RESULTS: The implant success rate was 95.5% (191/200) overall and 99% in patients ≤2 kg (99/100). The primary effectiveness endpoint was achieved in 99.4% of implanted patients. Four patients experienced a primary safety endpoint event (2 transfusions, 1 hemolysis, and 1 aortic obstruction). There were no branch pulmonary artery obstructions. Five patients, all ≤2 kg, were noted to have worsening of tricuspid regurgitation (TR) after the procedure. None of the TR incidences manifested clinically. The Amplatzer Piccolo Occluder received FDA approval in January 2019 and became the first device approved for PDA closure in patients ≥700 g. CONCLUSIONS: This study supports the safety and effectiveness of the Amplatzer Piccolo Occluder, particularly in patients between 700 g and 2 kg where there is currently a significant unmet need in the United States. ClinicalTrials.gov identifier: NCT03055858.
Asunto(s)
Cateterismo Cardíaco/instrumentación , Conducto Arterioso Permeable/terapia , Recien Nacido Extremadamente Prematuro , Recién Nacido de muy Bajo Peso , Dispositivo Oclusor Septal , Peso al Nacer , Cateterismo Cardíaco/efectos adversos , Circulación Coronaria , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/fisiopatología , Femenino , Edad Gestacional , Hemodinámica , Humanos , Recién Nacido , Masculino , Estudios Prospectivos , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento , Estados UnidosRESUMEN
The novel coronavirus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is highly infectious, carries significant morbidity and mortality, and has rapidly resulted in strained health care system and hospital resources. In addition to patient-related care concerns in infected individuals, focus must also relate to diminishing community spread, protection of staff, case selection, and concentration of resources. The current document based on available data and consensus opinion addresses appropriate catheterization laboratory preparedness for treating these patients, including procedure-room readiness to minimize external contamination, safe donning and doffing of personal protective equipment (PPE) to eliminate risk to staff, and staffing algorithms to minimize exposure and maximize team availability. Case selection and management of both emergent and urgent procedures are discussed in detail, including procedures that may be safely deferred or performed bedside.
Asunto(s)
Cateterismo Cardíaco/estadística & datos numéricos , Angiografía Coronaria/estadística & datos numéricos , Infecciones por Coronavirus/prevención & control , Infección Hospitalaria/prevención & control , Pandemias/prevención & control , Neumonía Viral/prevención & control , Guías de Práctica Clínica como Asunto/normas , COVID-19 , Cateterismo Cardíaco/normas , Cardiología , Angiografía Coronaria/métodos , Infecciones por Coronavirus/epidemiología , Femenino , Mortalidad Hospitalaria , Humanos , Laboratorios de Hospital , Liderazgo , Masculino , Mentores , Pandemias/estadística & datos numéricos , Equipo de Protección Personal/estadística & datos numéricos , Neumonía Viral/epidemiología , Sociedades Médicas , Análisis de Supervivencia , Estados UnidosRESUMEN
The society for cardiovascular angiography and interventions (SCAI) think tank is a collaborative venture that brings together interventional cardiologists, administrative partners, and select members of the cardiovascular industry community for high-level field-wide discussions. The 2020 think tank was organized into four parallel sessions reflective of the field of interventional cardiology: (a) coronary intervention, (b) endovascular medicine, (c) structural heart disease, and (d) congenital heart disease (CHD). Each session was moderated by a senior content expert and co-moderated by a member of SCAI's emerging leader mentorship program. This document presents the proceedings to the wider cardiovascular community in order to enhance participation in this discussion, create additional dialogue from a broader base, and thereby aid SCAI and the industry community in developing specific action items to move these areas forward.
Asunto(s)
Cateterismo Cardíaco/tendencias , Cardiología/tendencias , Angiografía Coronaria/tendencias , Cardiopatías/diagnóstico por imagen , Cardiopatías/terapia , Intervención Coronaria Percutánea/tendencias , Difusión de Innovaciones , Cardiopatías/fisiopatología , HumanosRESUMEN
OBJECTIVES: To define patient and ventricular size parameters to guide Impella device (Abiomed, Inc., Danvers, MA) placement for mechanical circulatory support (MCS) in small pediatric patients (10-30 kg). BACKGROUND: There are few options for MCS in children, and there are no data on minimum patient size requirements for placement of the Impella 2.5 device. METHODS: This was a multicenter study of echocardiographic and magnetic resonance imaging (MRI) derived dimensions of the left ventricle (LV) length and ascending aorta used to define minimum size parameters that are necessary for the placement of the Impella catheter. RESULTS: Data were collected from 44 cardiac MRIs conducted in healthy pediatric patients and 39 echocardiograms performed in pediatric patients with cardiomyopathy prior to surgical ventricular assist device (VAD) placement. The Impella 2.5 catheter is 7.5 cm from the pigtail to the aortic annulus marker, thus requiring an LV apical length of 7.5 cm to allow the device to function in an unconstrained fashion. In the cohort of patients undergoing consideration for VAD placement, a minimum LV length of 7.5 cm corresponded to a height of 122 cm, weight of 23 kg, and body surface area (BSA) of 0.89 m2 . In the MRI cohort, this corresponded to a height of 121 cm, weight of 23.9 kg, and BSA of 0.89 m2 . CONCLUSION: MCS with Impella devices is feasible in pediatric patients. This study defines anthropomorphic and anatomic measurements to guide providers in patient selection for MCS using the Impella devices.
Asunto(s)
Estatura , Peso Corporal , Toma de Decisiones Clínicas , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Implantación de Prótesis/instrumentación , Función Ventricular Izquierda , Superficie Corporal , Niño , Preescolar , Ecocardiografía , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/fisiopatología , Humanos , Lactante , Imagen por Resonancia Magnética , Masculino , Selección de Paciente , Diseño de Prótesis , Implantación de Prótesis/efectos adversos , Recuperación de la Función , Estudios Retrospectivos , Resultado del Tratamiento , Estados UnidosRESUMEN
OBJECTIVES: This study describes procedural and 1-year outcomes of the 16 mm Melody PB1016 valve in patients with dysfunctional RVOT conduits. BACKGROUND: The Melody PB1016 is a standard Melody valve produced from a 16 mm bovine jugular vein and is intended for deployment up to 20 mm. METHODS: This is a prospective, non-randomized, multicenter study of the procedural and short-term outcomes of Melody PB1016 TPV replacement within dysfunctional RVOT conduits. Data from eight centers were included in the analysis. RESULTS: During the study period, 39 patients underwent attempted Melody TPVR. Of the 39 patients, 30 underwent successful Melody TPVR. The majority of patients underwent placement of one or more stents prior to TPVR. There was a significant reduction in peak conduit pressure gradient following TPVR (38 mmHg vs. 11 mmHg, P < 0.001). There were three cases of confined conduit tears successfully treated with covered stents or the valve itself. Repeat catheterization was performed in one patient for early re-obstruction that was successfully treated with balloon valvuloplasty. At recent follow-up, there were no cases of more than mild valve regurgitation and the mean pulmonary valve gradient by echocardiogram remained reduced relative to pre-TPVR implant measurements (33.5 mmHg vs. 15.2 mmHg). There were no cases of valve stent fracture or endocarditis reported at the 1-year follow-up. CONCLUSIONS: Our analysis of TPVR with the PB1016 valve in RVOT conduits showed it to be safe and effective and can be performed in a wide range of conduit sizes with preserved valve function. ClinicalTrials.gov Identifier: NCT02347189.
Asunto(s)
Bioprótesis , Cateterismo Cardíaco/instrumentación , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Cardiopatías Congénitas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Venas Yugulares/trasplante , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/cirugía , Stents , Adolescente , Adulto , Animales , Canadá , Cateterismo Cardíaco/efectos adversos , Bovinos , Niño , Europa (Continente) , Femenino , Cardiopatías Congénitas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Xenoinjertos , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/fisiopatología , Recuperación de la Función , Resultado del Tratamiento , Estados Unidos , Adulto JovenRESUMEN
BACKGROUND: Pulmonary insufficiency is a consequence of transannular patch repair in Tetralogy of Fallot (ToF) leading to late morbidity and mortality. Transcatheter native outflow tract pulmonary valve replacement has become a reality. However, predicting a secure, atraumatic implantation of a catheter-based device remains a significant challenge due to the complex and dynamic nature of the right ventricular outflow tract (RVOT). We sought to quantify the differences in compression and volume for actual implants, and those predicted by pre-implant modeling. METHODS: We used custom software to interactively place virtual transcatheter pulmonary valves (TPVs) into RVOT models created from pre-implant and post Harmony valve implant CT scans of 5 ovine surgical models of TOF to quantify and visualize device volume and compression. RESULTS: Virtual device placement visually mimicked actual device placement and allowed for quantification of device volume and radius. On average, simulated proximal and distal device volumes and compression did not vary statistically throughout the cardiac cycle (P = 0.11) but assessment was limited by small sample size. In comparison to actual implants, there was no significant pairwise difference in the proximal third of the device (P > 0.80), but the simulated distal device volume was significantly underestimated relative to actual device implant volume (P = 0.06). CONCLUSIONS: This study demonstrates that pre-implant modeling which assumes a rigid vessel wall may not accurately predict the degree of distal RVOT expansion following actual device placement. We suggest the potential for virtual modeling of TPVR to be a useful adjunct to procedural planning, but further development is needed.
Asunto(s)
Cateterismo Cardíaco/instrumentación , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Modelos Cardiovasculares , Modelación Específica para el Paciente , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/cirugía , Tetralogía de Fallot/cirugía , Animales , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Humanos , Modelos Animales , Diseño de Prótesis , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/fisiopatología , Oveja Doméstica , Tomografía Computarizada por Rayos X , Resultado del TratamientoRESUMEN
OBJECTIVES: To quantify radiation exposure during pediatric cardiac catheterizations performed by multiple operators on a new imaging platform, the Artis Q.zen (Siemens Healthcare, Forchheim, Germany), and to compare these data to contemporary benchmark values. BACKGROUND: The Artis Q.zen has been shown to achieve significant radiation reduction during select types of pediatric cardiac catheterizations in small single-center studies. No large multicenter study exists quantifying patient dose exposure for a broad spectrum of procedures. METHODS: Retrospective collection of Air Kerma (AK) and dose area product (DAP) for all pediatric cardiac catheterizations performed on this new imaging platform at four institutions over a two-year time period. RESULTS: A total of 1,127 pediatric cardiac catheterizations were analyzed. Compared to dose data from earlier generation Artis Zee imaging systems, this study demonstrates 70-80% dose reduction (AK and DAP) for similar patient and procedure types. Compared to contemporary benchmark data for common interventional procedures, this study demonstrates an average percent reduction in AK and DAP from the lowest dose saving per intervention of 39% for AK and 27% for DAP for transcatheter pulmonary valve implantation up to 77% reduction in AK and 70% reduction in DAP for atrial septal defect closure. CONCLUSION: Use of next-generation imaging platforms for pediatric cardiac catheterizations can substantially decrease patient radiation exposure. This multicenter study defines new low-dose radiation measures achievable on a novel imaging system.
Asunto(s)
Cateterismo Cardíaco , Cardiopatías/diagnóstico por imagen , Cardiopatías/cirugía , Exposición a la Radiación , Radiografía Intervencional , Adolescente , Niño , Preescolar , Femenino , Fluoroscopía , Humanos , Lactante , Recién Nacido , Masculino , Dosis de Radiación , Estudios Retrospectivos , Medición de Riesgo , Factores de TiempoRESUMEN
We present a case of successful bicaval Melody valve implantation to treat severe mitral regurgitation in a 44-year-old man with d-transposition of the great arteries, repaired via a Mustard operation. The patient sustained injury to the anterior mitral valve leaflet during laser extraction of a ventricular pacing lead resulting in acute, severe, symptomatic mitral regurgitation. The presence of systemic venous baffles of similar caliber to right ventricular outflow tract conduits allowed for implantation of Melody valves within each baffle. The patient remains asymptomatic with excellent Melody valve function 14 months post procedure.
Asunto(s)
Operación de Switch Arterial , Remoción de Dispositivos/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Transposición de los Grandes Vasos/cirugía , Adulto , Operación de Switch Arterial/efectos adversos , Valvuloplastia con Balón , Ecocardiografía Doppler en Color , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/fisiopatología , Marcapaso Artificial/efectos adversos , Flebografía , Diseño de Prótesis , Radiografía Intervencional , Recuperación de la Función , Índice de Severidad de la Enfermedad , Transposición de los Grandes Vasos/fisiopatología , Resultado del TratamientoRESUMEN
BACKGROUND: The hybrid stage 1 palliation for hypoplastic left heart syndrome (HLHS) was first described in 1993 as a bridge to heart transplant for HLHS. There are limited data on this strategy as primary heart transplantation for HLHS has become less common. METHODS: This is an observational, single-center study comparing pre- and post-transplant outcomes of patients listed for transplant following hybrid palliation with those following surgical stage 1 palliation. RESULTS: From 2004 to 2017, 21 patients underwent hybrid palliation as a bridge to heart transplant and 28 patients were listed for transplant following surgical stage 1 palliation or aortic arch repair and pulmonary artery band placement. Premature birth and the presence of genetic or anatomic abnormalities were more common in the hybrid group. Need for extracorporeal membrane oxygenation (ECMO) support and ventricular dysfunction was more common in the surgical group. There was a trend toward shorter waitlist times in the surgical cohort (36 days vs 70 days, P = 0.06). There was no difference in waitlist mortality (19% vs 21%, P = 0.61). Survival at 1 and 5 years post-transplant was similar for the hybrid and surgical cohorts (5-year survival, 80% vs 85%, P = 0.94, respectively). There was no difference in the number of post-transplant interventions. CONCLUSIONS: Although the hybrid patients represented a higher risk cohort and demonstrated longer wait times, the waitlist and post-transplant mortality was equivalent between the two groups. For high-risk patients, the hybrid palliation as a bridge to transplant appears to be a reasonable strategy.
Asunto(s)
Trasplante de Corazón/métodos , Ventrículos Cardíacos/fisiopatología , Síndrome del Corazón Izquierdo Hipoplásico/cirugía , Cuidados Paliativos/métodos , Aorta Torácica/cirugía , Cardiología/métodos , Femenino , Puente Cardíaco Derecho , Humanos , Lactante , Recién Nacido , Masculino , Arteria Pulmonar/cirugía , Estudios Retrospectivos , Riesgo , Resultado del Tratamiento , Listas de EsperaRESUMEN
OBJECTIVES: The objective was to review the use of Impella devices (Abiomed Inc, Danvers, MA) for temporary circulatory support in pediatric and adolescent patients (age ≤ 21 yrs). BACKGROUND: Options for minimally invasive circulatory support in children are limited, and published data are confined to case reports and small case series. METHODS: This was a retrospective, multicenter review of Impella implants in pediatric and adolescent patients from 2009-15, using standardized data collection and INTERMACS definitions. RESULTS: A total of 39 implants were performed in 38 patients from 16 centers. Median age and weight were 16 yrs (4-21 yrs) and 62 kg (15-134 kg). The primary indication for implant was cardiogenic shock in 28 patients (72%). Cardiac allograft rejection, myocarditis, or cardiomyopathy were the underlying diagnosis in 23 patients (59%); 11 patients had congenital heart disease. The median duration of support was 45 hr (1-1224 hr). Indications for explant included ventricular recovery in 16 patients, transition to another device in 12, death in 5, and transplant in 1. Survival was 85% at 7 days and 68% at 30 days. Major adverse events occurred in 8 patients: hemolysis in 3, bleeding in 2, stroke in 1 (unclear if related to Impella), sepsis in 1, and critical leg ischemia in 1. An increase in aortic regurgitation was noted in three patients, with no evidence of valve injury. CONCLUSION: Temporary circulatory support with Impella devices is feasible in pediatric and adolescent patients, with acceptable risk profiles. More experience and follow up is needed to improve technical performance and patient selection. © 2017 Wiley Periodicals, Inc.
Asunto(s)
Procedimiento de Fontan/efectos adversos , Cardiopatías Congénitas/cirugía , Corazón Auxiliar , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Adolescente , Niño , Preescolar , Estudios de Factibilidad , Femenino , Cardiopatías Congénitas/fisiopatología , Humanos , Masculino , Diseño de Prótesis , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Izquierda/fisiopatología , Adulto JovenRESUMEN
BACKGROUND: There are limited mechanical circulatory support options for patients with single ventricle (SV) anatomy. This is a multicenter, retrospective study of the Impella pump to support the systemic ventricle in a cohort of SV patients with Fontan circulation. METHODS: Patients with SV anatomy supported with an Impella device from 2012 to 2015 were included. Demographic information, indication for support, adverse events and short-term outcome data were collected. RESULTS: Ten patients were included. The median age and weight at implant was 26 years (4-38 years) and 64 kg (15-102 kg). Indications for support were systemic ventricular failure with cardiogenic shock (n = 8) or high-risk electrophysiology (EP) procedures (n = 2). The median duration of support was 49 hr (2.7-264 hr). Support was discontinued for ventricular recovery in five patients, transition to another device in two patients, completion of EP procedure in two patients and death in one patient. Survival to hospital discharge was 80%. Adverse events occurred in 4 patients. There were two cases of hemolysis, one case of increasing aortic valve insufficiency with implant and one asymptomatic access site thrombus. There were no bleeding or thromboembolic events. CONCLUSIONS: Impella devices can provide temporary support for the systemic ventricle in SV patients as a bridge to recovery or additional device. Procedural survival and adverse event profiles are favorable. © 2017 Wiley Periodicals, Inc.