Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Nature ; 632(8023): 131-138, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39020167

RESUMEN

A single dose of psilocybin, a psychedelic that acutely causes distortions of space-time perception and ego dissolution, produces rapid and persistent therapeutic effects in human clinical trials1-4. In animal models, psilocybin induces neuroplasticity in cortex and hippocampus5-8. It remains unclear how human brain network changes relate to subjective and lasting effects of psychedelics. Here we tracked individual-specific brain changes with longitudinal precision functional mapping (roughly 18 magnetic resonance imaging visits per participant). Healthy adults were tracked before, during and for 3 weeks after high-dose psilocybin (25 mg) and methylphenidate (40 mg), and brought back for an additional psilocybin dose 6-12 months later. Psilocybin massively disrupted functional connectivity (FC) in cortex and subcortex, acutely causing more than threefold greater change than methylphenidate. These FC changes were driven by brain desynchronization across spatial scales (areal, global), which dissolved network distinctions by reducing correlations within and anticorrelations between networks. Psilocybin-driven FC changes were strongest in the default mode network, which is connected to the anterior hippocampus and is thought to create our sense of space, time and self. Individual differences in FC changes were strongly linked to the subjective psychedelic experience. Performing a perceptual task reduced psilocybin-driven FC changes. Psilocybin caused persistent decrease in FC between the anterior hippocampus and default mode network, lasting for weeks. Persistent reduction of hippocampal-default mode network connectivity may represent a neuroanatomical and mechanistic correlate of the proplasticity and therapeutic effects of psychedelics.


Asunto(s)
Encéfalo , Alucinógenos , Imagen por Resonancia Magnética , Metilfenidato , Psilocibina , Humanos , Psilocibina/farmacología , Psilocibina/administración & dosificación , Masculino , Alucinógenos/farmacología , Alucinógenos/administración & dosificación , Adulto , Encéfalo/efectos de los fármacos , Encéfalo/fisiología , Encéfalo/diagnóstico por imagen , Femenino , Metilfenidato/farmacología , Metilfenidato/administración & dosificación , Adulto Joven , Mapeo Encefálico , Voluntarios Sanos , Hipocampo/efectos de los fármacos , Hipocampo/fisiología , Hipocampo/diagnóstico por imagen , Red Nerviosa/efectos de los fármacos , Red Nerviosa/fisiología , Red Nerviosa/diagnóstico por imagen
2.
Neuroimage ; 273: 120057, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37001834

RESUMEN

When does the mind begin? Infant psychology is mysterious in part because we cannot remember our first months of life, nor can we directly communicate with infants. Even more speculative is the possibility of mental life prior to birth. The question of when consciousness, or subjective experience, begins in human development thus remains incompletely answered, though boundaries can be set using current knowledge from developmental neurobiology and recent investigations of the perinatal brain. Here, we offer our perspective on how the development of a sensory perturbational complexity index (sPCI) based on auditory ("beep-and-zip"), visual ("flash-and-zip"), or even olfactory ("sniff-and-zip") cortical perturbations in place of electromagnetic perturbations ("zap-and-zip") might be used to address this question. First, we discuss recent studies of perinatal cognition and consciousness using techniques such as functional magnetic resonance imaging (fMRI), electroencephalography (EEG), and, in particular, magnetoencephalography (MEG). While newborn infants are the archetypal subjects for studying early human development, researchers may also benefit from fetal studies, as the womb is, in many respects, a more controlled environment than the cradle. The earliest possible timepoint when subjective experience might begin is likely the establishment of thalamocortical connectivity at 26 weeks gestation, as the thalamocortical system is necessary for consciousness according to most theoretical frameworks. To infer at what age and in which behavioral states consciousness might emerge following the initiation of thalamocortical pathways, we advocate for the development of the sPCI and similar techniques, based on EEG, MEG, and fMRI, to estimate the perinatal brain's state of consciousness.


Asunto(s)
Encéfalo , Estado de Conciencia , Lactante , Niño , Recién Nacido , Embarazo , Femenino , Humanos , Cognición , Magnetoencefalografía , Electroencefalografía/métodos
3.
J Cardiovasc Electrophysiol ; 34(9): 1802-1807, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37473404

RESUMEN

INTRODUCTION: Pulsed-field ablation (PFA) and the multielectrode radiofrequency balloon (RFB) are two novel ablation technologies to perform pulmonary vein isolation (PVI). It is currently unknown whether these technologies differ in lesion formation and lesion extent. We compared the acute lesion extent after PVI induced by PFA and RFB by measuring low-voltage area in high-density maps and the release of biomolecules reflecting cardiac injury. METHODS: PVI was performed with a pentaspline catheter (FARAPULSE) applying PFA or with the compliant multielectrode RFB (HELIOSTAR). Before and after PVI high-density mapping with CARTO 3 was performed. In addition, blood samples were taken before transseptal puncture and after post-PVI remapping and serum concentrations of high-sensitive Troponin I were quantified by immunoassay. RESULTS: Sixty patients undergoing PVI by PFA (n = 28, age 69 ± 12 year, 60% males, 39.3% persistent atrial fibrillation [AF]) or RFB (n = 32, age 65 ± 13 year, 53% males, 21.9% persistent AF) were evaluated. Acute PVI was achieved in all patients in both groups. Mean number of PFA pulses was 34.2 ± 4.5 and mean number RFB applications was 8.5 ± 3 per patient. Total posterior ablation area was significantly larger in PFA (20.7 ± 7.7 cm²) than in RFB (7.1 ± 2.09 cm²; p < .001). Accordingly, posterior ablation area for each PV resulted in larger lesions after PFA versus RFB (LSPV 5.2 ± 2.7 vs. 1.9 ± 0.8 cm², LIPV 5.5 ± 2.3 vs. 1.9 ± 0.8 cm², RSPV 4.7 ± 1.9 vs. 1.6 ± 0.5 cm², RIPV 5.3 ± 2.1 vs. 1.6 ± 0.7 cm,² respectively; p < .001). In a subset of 38 patients, increase of hsTropI was higher after PFA (625 ± 138 pg/mL, n = 28) versus RFB (148 ± 36 pg/mL, n = 10; p = .049) supporting the evidence of larger lesion extent by PFA. CONCLUSION: PFA delivers larger acute lesion areas and higher troponin release upon successful PVI than multielectrode RFB-based PVI in this single-center series.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Venas Pulmonares/cirugía , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Catéteres
4.
Circ J ; 87(7): 950-956, 2023 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-37286488

RESUMEN

BACKGROUND: A novel multielectrode radiofrequency balloon (RFB) catheter has been released for pulmonary vein isolation (PVI).Methods and Results: In this observational study consecutive patients with drug-refractory paroxysmal or persistent atrial fibrillation (AF) undergoing first-time PVI were enrolled in 2 high-volume ablation centers. All procedures were conducted in conjunction with a 3D-mapping system. Clinical, procedural and ablation parameters were systematically analyzed. 105 patients (58% male; 52% paroxysmal AF, 68±11.3 years mean age, left atrial volume index 38.6±14.8 mL/m2) were included. 241/412 (58.5%) PVs were successfully isolated with a single shot (SS), with a time-to-isolation of 11.6±8 s. Total number of radiofrequency applications was 892 (mean 2.2/PV), resulting in successful isolation of 408/412 (99%) PVs at the end of the procedure. Mean electrodes' impedance drop was significantly higher in the SS-PVI compared with non-SS applications (21.5±6.6 vs. 18.6±6.5 Ohm). Concordantly, higher temperature rise was observed in the SS vs. non-SS applications (10.9±4.9℃ vs. 9.6±4.7℃). CONCLUSIONS: In this multicenter real-world study, mean impedance drop and temperature rise were associated with successful SS-PVI applying the novel RFB catheter. These parameters may help to guide efficient usage of the new RF balloon.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Femenino , Resultado del Tratamiento , Ablación por Catéter/métodos , Fibrilación Atrial/cirugía , Atrios Cardíacos , Venas Pulmonares/cirugía , Catéteres , Recurrencia
5.
Macromol Rapid Commun ; 44(16): e2200332, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35689352

RESUMEN

Bioderived polymers are one of many current research areas that promise a sustainable future. Due to their unique properties, the bioderived polymer polydopamine has been in the spotlight over the last decades. Its ability to adhere to virtually any surface and its stability over a wide pH range as well as in several organic solvents make it a suitable candidate for various applications like coatings and biosensors. However, strong light absorption over a broad range of wavelengths and high quenching efficiency limit its uses. Therefore, new bioderived polymers with similar features to polydopamine but without fluorescence quenching properties are highly desirable. Herein, the electropolymerization of a bioderived analog of dopamine, 3-amino-l-tyrosine, is demonstrated. The resulting polymer, poly(amino-l-tyrosine), exhibits several characteristics complementary to or even exceeding those of polydopamine and its analog, polynorepinephrine, rendering poly(amino-l-tyrosine) attractive for the development of sensors and photoactive devices. Cyclic voltammetry, spectro-electrochemistry, and electrochemical quartz crystal microbalance measurements are applied to study the electrodeposition of this material, and the resulting films are compared to polydopamine and polynorepinephrine. Impedance spectroscopy reveals increased ion permeability of poly(amino-l-tyrosine) compared to polydopamine and polynorepinephrine. Moreover, the reduced fluorescence quenching of poly(amino-l-tyrosine) supports its use as coating for biosensors and organic semiconductors.


Asunto(s)
Técnicas Biosensibles , Polímeros , Polímeros/química , Tirosina , Dopamina/química , Tecnicas de Microbalanza del Cristal de Cuarzo
6.
J Cardiovasc Electrophysiol ; 33(1): 48-54, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34766404

RESUMEN

INTRODUCTION: Cryoballoon (CB) ablation for pulmonary vein isolation (PVI) is an effective treatment of atrial fibrillation (AF). Recently, a novel cryoablation system was introduced. The aim of the study was to compare the safety, efficacy and biophysical characteristics of a novel cryoablation system (POLARx™; Boston Scientific) to a commonly used and clinically well characterized system (Arctic Front Advance Pro™, AFA; Medtronic). METHODS AND RESULTS: Fifty consecutive patients with symptomatic AF, who underwent CB-based ablation with the POLARx were compared to 50 consecutive patients treated with the AFA. Acute PVI was achieved in 99.8% (POLARx 99.5%, AFA 100%, p = 1.00). Time to isolation (TTI) was comparable in both groups (POLARx 35 [27, 48] s, AFA 30 [21, 43] s, p = 0.165). The POLARx showed a lower balloon temperature at TTI (POLARx -44 [-50, -36] °C, AFA -31 [-38, -21] °C, p < 0.001) and lower nadir temperature (POLARx -60 [-65, -55] °C, AFA -48 [-54, -45] °C, p < 0.001). Procedure time (POLARx 80 [60, 105] min, AFA 62 [42, 80] min, p < 0.001), fluoroscopy time (POLARx 17 [13, 22] min, AFA 11 [7, 16] min, p < 0.001) and freeze cycles per patient (POLARx 5 [4, 6], AFA 4.5 [4, 5], p = 0.002) were higher in the POLARx group. Two cerebral ischemic events occurred in the POLARx group, two patients in each group had phrenic nerve injury. CONCLUSION: Both systems enable effective isolation of pulmonary veins. The POLARx required longer procedure and fluoroscopy times. Larger, prospective and randomized studies are needed to assess long-term efficacy and safety of this technology.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Criocirugía/métodos , Humanos , Estudios Prospectivos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Tecnología , Resultado del Tratamiento
7.
Eur Eat Disord Rev ; 30(1): 75-81, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34713530

RESUMEN

OBJECTIVE: Maternal eating disorders (EDs) are associated with adverse pregnancy and child outcomes. There is limited research investigating the influence of maternal EDs on foetal brain development. METHOD: Using foetal magnetoencephalography (fMEG), an auditory sequence was presented for 10 min to assess brain response latencies in foetuses of mothers with (n = 12) and without (n = 11) a history of anorexia nervosa (AN) in the third trimester of pregnancy. ED history and severity were assessed using the structured clinical expert interview eating disorder examination (EDE) and the self-report questionnaire EDE-Q. RESULTS: Foetuses of mothers with AN showed delayed foetal brain responses to auditory stimulation compared to foetuses of control women. Self-reported ED symptom severity explained 34% of variance in foetal brain response latencies in the AN group. CONCLUSIONS: ED pathology was strongly associated with foetal brain response latencies in the third trimester with longer latencies in foetuses of women with a history of AN reporting more ED symptoms. Follow-up on the children is pivotal to investigate if fMEG outcomes are associated with later child development.


Asunto(s)
Anorexia Nerviosa , Trastornos de Alimentación y de la Ingestión de Alimentos , Anorexia Nerviosa/diagnóstico , Encéfalo , Niño , Trastornos de Alimentación y de la Ingestión de Alimentos/diagnóstico , Femenino , Humanos , Embarazo , Encuestas y Cuestionarios
8.
Int Heart J ; 63(3): 504-509, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35650152

RESUMEN

Pulmonary vein (PV) isolation (PVI) by continuous, transmural and durable lesions is decisive for ensuring long-term freedom from atrial fibrillation (AF). AF ablation requires irrigated tip catheters to reduce thromboembolic complications. This precluded temperature-controlled delivery of radiofrequency (RF) energy.The aim of this study was to evaluate feasibility, acute efficacy, and safety of an irrigated, temperature-controlled ablation catheter [DiamondTemp™ (DT) Medtronic®] for PVI.Consecutive patients with AF underwent PVI using the DT catheter combined with high-power short-duration RF applications. Ablation settings were (1) a catheter tip temperature limit of 60°C, (2) a temperature-controlled power of 50 W, and (3) application duration of 10 seconds. The primary endpoint was acute isolation of PVs, reassessed after a 30-minute waiting period. Secondary endpoints included procedural parameters (defined as a catheter tip temperature of 50°C > 3 seconds, an impedance drop of 5-10 Ω) and the occurrence of serious adverse events.Fifty consecutive patients [mean age 66 ± 12 years, 38 (76%) women, 24 patients with paroxysmal AF (48%)] were included. Median procedure and left atrial dwell time was 89 [68; 107] and 63 [52; 79] minutes, respectively. Mean number of RF applications was 59 ± 20, and mean total RF duration was 14 ± 6 minutes. Acute PVI was achieved in all patients solely using DT ablation. Acute PV reconnection within the waiting period occurred in five patients; all reconnected PVs were successfully reisolated. One major complication occurred.In this study, the DT ablation system demonstrated high acute efficacy for PVI. Temperature-controlled ablation in conjunction with high-power short-duration applications might be effectively supported.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Resultado del Tratamiento
9.
Neuroimage ; 240: 118378, 2021 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-34246769

RESUMEN

Humans are highly attuned to patterns in the environment. This ability to detect environmental patterns, referred to as statistical learning, plays a key role in many diverse aspects of cognition. However, the spatiotemporal neural mechanisms underlying implicit statistical learning, and how these mechanisms may relate or give rise to explicit learning, remain poorly understood. In the present study, we investigated these different aspects of statistical learning by using an auditory nonlinguistic statistical learning paradigm combined with magnetoencephalography. Twenty-four healthy volunteers were exposed to structured and random tone sequences, and statistical learning was quantified by neural entrainment. Already early during exposure, participants showed strong entrainment to the embedded tone patterns. A significant increase in entrainment over exposure was detected only in the structured condition, reflecting the trajectory of learning. While source reconstruction revealed a wide range of brain areas involved in this process, entrainment in areas around the left pre-central gyrus as well as right temporo-frontal areas significantly predicted behavioral performance. Sensor level results confirmed this relationship between neural entrainment and subsequent explicit knowledge. These results give insights into the dynamic relation between neural entrainment and explicit learning of triplet structures, suggesting that these two aspects are systematically related yet dissociable. Neural entrainment reflects robust, implicit learning of underlying patterns, whereas the emergence of explicit knowledge, likely built on the implicit encoding of structure, varies across individuals and may depend on factors such as sufficient exposure time and attention.


Asunto(s)
Estimulación Acústica/métodos , Percepción Auditiva/fisiología , Encéfalo/fisiología , Aprendizaje/fisiología , Magnetoencefalografía/métodos , Red Nerviosa/fisiología , Adulto , Femenino , Humanos , Masculino , Adulto Joven
10.
J Cardiovasc Electrophysiol ; 32(2): 376-388, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33368769

RESUMEN

INTRODUCTION: Substrate-based catheter ablation approaches to ventricular tachycardia (VT) focus on low-voltage areas and abnormal electrograms. However, specific electrogram characteristics in sinus rhythm are not clearly defined and can be subject to variable interpretation. We analyzed the potential ablation target size using automatic abnormal electrogram detection and studied findings during substrate mapping in the VT isthmus area. METHODS AND RESULTS: Electrogram characteristics in 61 patients undergoing scar-related VT ablation using ultrahigh-density 3D-mapping with a 64-electrode mini-basket catheter were analyzed retrospectively. Forty-four complete substrate maps with a mean number of 10319 ± 889 points were acquired. Fractionated potentials detected by automated annotation and manual review were present in 43 ± 21% of the entire low-voltage area (<1.0 mV), highly fractionated potentials in 7 ± 8%, late potentials in 13 ± 15%, fractionated late potentials in 7 ± 9% and isolated late potentials in 2 ± 4%, respectively. Highly fractionated potentials (>10 ± 1 fractionations) were found in all isthmus areas of identified VT during substrate mapping, while isolated late potentials were distant from the critical isthmus area in 29%. CONCLUSION: The ablation target area varies enormously in size, depending on the definition of abnormal electrograms. Clear linking of abnormal electrograms with critical VT isthmus areas during substrate mapping remains difficult due to a lack of specificity rather than sensitivity. However, highly fractionated, low-voltage electrograms were found to be present in all critical VT isthmus sites.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Cicatriz/diagnóstico , Cicatriz/etiología , Humanos , Estudios Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía
11.
Europace ; 21(Supplement_1): i34-i42, 2019 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-30801126

RESUMEN

AIMS: A novel measure of local impedance (LI) has been found to predict lesion formation during radiofrequency current (RFC) catheter ablation. The aim of this study was to investigate the utility of this novel approach, while comparing LI to the well-established generator impedance (GI). METHODS AND RESULTS: In 25 consecutive patients with a history of atrial fibrillation, catheter ablation was guided by a 3D-mapping system measuring LI in addition to GI via an ablation catheter tip with three incorporated mini-electrodes. Local impedance and GI before and during RFC applications were studied. In total, 381 RFC applications were analysed. The baseline LI was higher in high-voltage areas (>0.5 mV; LI: 110.5 ± 13.7 Ω) when compared with intermediate-voltage sites (0.1-0.5 mV; 90.9 ± 10.1 Ω, P < 0.001), low-voltage areas (<0.1 mV; 91.9 ± 16.4 Ω, P < 0.001), and blood pool LI (91.9 ± 9.9 Ω, P < 0.001). During ablation, mean LI drop (△LI; 13.1 ± 9.1 Ω) was 2.15 times higher as mean GI drop (△GI) (6.1 ± 4.2 Ω, P < 0.001). Baseline LI correlated with △LI: a mean LI of 99.9 Ω predicted a △LI of 12.9 Ω [95% confidence interval (12.1-13.6), R2 0.41; P < 0.001]. This relationship was weak for baseline GI predicting △GI (R2 0.06, P < 0.001). Catheter movements were represented by rapid LI changes. The duration of an RFC application was not predictive for catheter-tissue coupling with no further change of △LI (P = 0.247) nor △GI (P = 0.376) during prolonged ablation. CONCLUSION: Local impedance can be monitored during ablation. Compared with the sole use of GI, baseline LI is a better predictor of impedance drops during ablation and may provide useful insights regarding lesion formation. However, further studies are needed to investigate if this novel approach is useful to guide catheter ablation.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Impedancia Eléctrica , Anciano , Mapeo Epicárdico , Femenino , Humanos , Masculino , Proyectos Piloto , Ondas de Radio
12.
J Cardiovasc Electrophysiol ; 29(4): 537-547, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29377448

RESUMEN

AIMS: To evaluate the incidence of newly diagnosed intracardiac thrombi (ICT) in respect to the mode of OAC in patients undergoing cardioversion (CV). METHODS AND RESULTS: We prospectively assessed transesophageal echocardiography (TEE) and OAC therapy prior to CV in AF patients with ≥48-hour duration scheduled for CV. A total of 60 first-time ICT (4.7%) were diagnosed in 1,286 TEE, with highest rate in patients without OAC (9.6% vs. OAC 4.1%, P  =  0.009) and an apparently lower rate in nonvitamin K antagonist anticoagulants (NOAC) therapy compared to vitamin K antagonist (VKA) (2.5% vs. 5.3%, P  =  0.02). VKA therapy control 4 weeks prior to CV was overall average (time in therapeutic range 60%) and patients showed more frequently clinical characteristics and TEE parameters associated with risk for ICT. Even among patients with effective OAC therapy (uninterrupted NOAC and VKA therapy with international normalized ratio (INR) ≥2.0 for 3 weeks), ICT occurred in 2.7%, but with no difference between both groups (P  =  0.22). There was no difference between different types of NOAC. Independent predictors for ICT were history of embolism, hypertension, BMI, absence of OAC, renal function, reduced atrial appendage flow, and presence of spontaneous echo contrast. CONCLUSION: NOAC therapy seems favorable in the overall prevention of ICT, although this is likely to be caused by suboptimal VKA therapy control and differences in the overall health status between VKA and NOAC patients. ICT occurred even with effective OAC therapy suggesting individual TEE-guided cardioversion in patients at risk.


Asunto(s)
Anticoagulantes/administración & dosificación , Fibrilación Atrial/terapia , Trombosis/prevención & control , Administración Oral , Anciano , Anticoagulantes/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Ecocardiografía Doppler de Pulso , Ecocardiografía Transesofágica , Cardioversión Eléctrica , Electrocardiografía , Femenino , Estado de Salud , Humanos , Incidencia , Relación Normalizada Internacional , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Factores de Tiempo , Resultado del Tratamiento
13.
Europace ; 20(3): 520-527, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-28340078

RESUMEN

Aims: During ablation in the vicinity of the coronary arteries establishing a safe distance from the catheter tip to the relevant vessels is mandatory and usually assessed by fluoroscopy alone. The aim of the study was to investigate the feasibility of an image integration module (IIM) for continuous monitoring of the distance of the ablation catheter tip to the main coronary arteries during ablation of ventricular arrhythmias (VA) originating in the sinus of valsalva (SOV) and the left ventricular summit part of which can be reached via the great cardiac vein (GCV). Methods and results: Of 129 patients undergoing mapping for outflow tract arrhythmias from June 2014 till October 2015, a total of 39 patients (52.4 ± 18.1 years, 17 female) had a source of origin in the SOV or the left ventricular summit. Radiofrequency (RF) ablation was performed when a distance of at least 5 mm could be demonstrated with IIM. A safe distance in at least one angiographic plane could be demonstrated in all patients with a source of origin in the SOV, whereas this was not possible in 50% of patients with earliest activation in the summit area. However, using the IIM a safe position at an adjacent site within the GCV could be obtained in three of these cases and successful RF ablation performed safely without any complications. Ablation was successful in 100% of patients with an origin in the SOV, whereas VAs originating from the left ventricular summit could be abolished completely in only 60% of cases. Conclusion: Image integration combining electroanatomical mapping and fluoroscopy allows assessment of the safety of a potential ablation site by continuous real-time monitoring of the spatial relations of the catheter tip to the coronary vessels prior to RF application. It aids ablation in anatomically complex regions like the SOV or the ventricular summit providing biplane angiograms merged into the three-dimensional electroanatomical map.


Asunto(s)
Arritmias Cardíacas/cirugía , Ablación por Catéter , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Técnicas Electrofisiológicas Cardíacas , Ventrículos Cardíacos/cirugía , Imagenología Tridimensional , Interpretación de Imagen Radiográfica Asistida por Computador , Seno Aórtico/cirugía , Potenciales de Acción , Adulto , Anciano , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/fisiopatología , Ablación por Catéter/efectos adversos , Estudios de Factibilidad , Femenino , Fluoroscopía , Frecuencia Cardíaca , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Factores de Riesgo , Seno Aórtico/diagnóstico por imagen , Seno Aórtico/fisiopatología , Resultado del Tratamiento , Función Ventricular Izquierda
14.
Europace ; 20(1): 43-49, 2018 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-27742775

RESUMEN

Introduction: Comparative data of early recurrence rates of atrial fibrillation (ERAF) following second-generation cryoballoon (CB-G2) and radiofrequency current (RFC) ablation for pulmonary vein isolation (PVI) in paroxysmal AF (PAF) are rare. We randomized PAF patients into either PVI with CB-G2 (group 1) or PVI with a combined RFC-approach applying contact force (CF) with the endpoint of unexcitability (group 2) to investigate ERAF. Methods and results: In group 1 (n = 30), CB-G2-PVI was performed. After CF-PVI in group 2 (n = 30), bipolar pacing on the ablation line and additional ablation until unexcitability was conducted. Follow-up included 48 h of in-hospital monitoring followed by 5-day Holter ECGs 1, 2, 3, 6, 12 months postablation to evaluate ERAF. Acute PVI was reached in 100% of group 2 and in 99% of group 1. Shorter procedure durations (98.0 ± 21.9 vs. 114.3 ± 18.7 min, P < 0.05) but extended fluoroscopy times (15.4 ± 3.9 vs. 10.0 ± 4.3 min, P < 0.05) were found in the CB-G2 group. Ten non-severe complications occurred (6 vs. 4 in group 1 and 2, P = 0.73). In group 2, five patients suffered from ERAF vs. seven patients in group 1 (P = 0.67). The time until the occurrence of ERAF was shorter in group 2 (1 day (q1-q3: 1-4.5)) when compared with group 1 (22 (q1-q3: 6-54) days, P = 0.025). Conclusion: ERAF rates were equal among groups; however, they occurred earlier in the initial phase after RFC ablation when compared with CB-G2. PVI utilizing cryoablation is associated with shorter procedure durations but extended fluoroscopy time while being similarly secure.


Asunto(s)
Fibrilación Atrial/cirugía , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Criocirugía/instrumentación , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Estimulación Cardíaca Artificial , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Electrocardiografía Ambulatoria , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Femenino , Fluoroscopía , Alemania , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Proyectos Piloto , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Radiografía Intervencional , Recurrencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
15.
J Cardiovasc Electrophysiol ; 28(9): 1058-1067, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28597532

RESUMEN

BACKGROUND: Ablation of scar-related ventricular tachycardia (VT), especially in noninducible VT or hemodynamically unstable patients, can be challenging. Thus, we evaluated feasibility of an ultra high-density 3-D mapping approach to characterize the ventricular substrate and, if possible, to map VT. METHODS AND RESULTS: Twenty-two patients (67 ± 2 years, mean LV-EF 36 ± 3%) with both ischemic and nonischemic cardiomyopathy and documented VT underwent mapping and catheter ablation using a 64-electrode mini-basket catheter. Substrate characterization included ultra high-density voltage maps, identification of areas of slow conduction and late potentials. Whenever VT was inducible activation mapping was performed. In 13 of 22 patients, the presumed clinical VT (in 16 of 22 any VT) was inducible. A total of 50 maps were generated (22 substrate maps, 28 during VT), mapping time was 33 ± 4 minutes, number of points was 10,937 ± 1,923. Low voltage areas were related with the site of origin in all mapped VT. Isochronal maps indicated areas of slow conduction in 14 of 22 patients, all in border zone scar. In 95% of patients, late potentials were found. Mapping time during VT was 9 ± 2 minutes, number of points 6,740 ± 1,140. Covered cycle length was 82 ± 5% (16 re-entry, 10 focal, and two undetermined). During 4 months follow-up, 90% remained free from VT recurrence. CONCLUSION: Ultra high-density mapping in patients with scar-related VT is feasible, safe and enables detailed insight into tachycardia mechanisms. Critical sites can be identified (1) by precise substrate characterization when VT is not inducible or hemodynamically not tolerated and (2) during short lasting episodes of VT in order to guide catheter ablation.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Cardiomiopatías/complicaciones , Ablación por Catéter/métodos , Cicatriz/complicaciones , Frecuencia Cardíaca/fisiología , Imagenología Tridimensional/métodos , Taquicardia Ventricular/cirugía , Anciano , Cardiomiopatías/diagnóstico , Cicatriz/diagnóstico , Electrocardiografía , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Curva ROC , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Resultado del Tratamiento
16.
J Cardiovasc Electrophysiol ; 28(10): 1127-1136, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28635023

RESUMEN

INTRODUCTION: The need for transesophageal echocardiography (TEE) before catheter ablation of atrial fibrillation (CA-AF) is still being questioned. The aim of this study is to analyze patients' (patients) risk factors of left atrial appendage thrombus (LAAT) prior to CA-AF in daily clinical practice, according to oral anticoagulation (OAC) strategies recommended by current guidelines. METHODS AND RESULTS: All patients scheduled for CA-AF from 01/2015 to 12/2016 in our center were included and either treated with NOACs (novel-OAC; paused 24-hours preablation) or continuous vitamin K antagonists (INR 2.0-3.0). All patients received a preprocedural TEE at the day of ablation. Two groups were defined: (1) patients without LAAT, (2) patients with LAAT. The incidence of LAAT was 0.78% (13 of 1,658 patients). No LAAT was detected in patients with a CHA2 DS2 -VASc score of ≤1 (n = 640 patients) irrespective of the underlying AF type. Independent predictors for LAAT are: higher CHA2 DS2 -VASc scores (odds ratio [OR] 1.54, 95%-confidence interval [CI]: 1.07-2.23, P = 0.0019), a history of nonparoxysmal AF (OR 7.96, 95%-CI: 1.52-146.64, P = 0.049), hypertrophic cardiomyopathy (HCM; OR 9.63, 95% CI: 1.36-43.05, P = 0.007), and a left ventricular ejection fraction (LVEF) < 30% (OR 8.32, 95% CI: 1.18-36.29, P = 0.011). The type of OAC was not predictive (P = 0.70). CONCLUSIONS: The incidence of LAAT in patients scheduled for CA-AF is low. Therefore, periprocedural OAC strategies recommended by current guidelines seem feasible. Preprocedural TEE may be dispensed in patients with a CHA2 DS2 -VASc score ≤1. However, a CHA2 DS2 -VASc score ≥2, reduced LVEF, HCM, or history of nonparoxysmal AF are independently associated with an increased risk for LAAT.


Asunto(s)
Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Ecocardiografía Transesofágica/métodos , Trombosis/diagnóstico por imagen , Anciano , Antiarrítmicos/uso terapéutico , Anticoagulantes/uso terapéutico , Fibrilación Atrial/epidemiología , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Estudios de Cohortes , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Medicina de Precisión , Valor Predictivo de las Pruebas , Medición de Riesgo , Volumen Sistólico , Trombosis/tratamiento farmacológico , Trombosis/epidemiología , Resultado del Tratamiento , Vitamina K/antagonistas & inhibidores
17.
J Cardiovasc Electrophysiol ; 28(3): 258-265, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27925337

RESUMEN

INTRODUCTION: Despite a rising demand for catheter ablation (CA) of atrial fibrillation (AF) in an elderly population, complication and success rates are not fully elucidated. We sought to compare complication rates of CA of AF in patients ≥75 versus <75 years of age. METHODS AND RESULTS: Patients with symptomatic, drug-refractory AF were prospectively enrolled from January 2007 to 2010 in this multicenter study. A total of 4,449 patients, group 1 ≥75 years and group 2 <75 years (n = 227, age 77.3 ± 2.2 vs. 59.7 ± 9.8 years, 52.0% vs. n = 4,222, 68.9% male, CHA2 DS2 -VASc-Score 3.7 ± 1.0 vs. 1.7 ± 1.2; P < 0.001, respectively), with paroxysmal AF (59.9% in group 1 vs. 63.3% in group 2, P = 0.30), and persistent AF (34.8% in group 1 vs. 29.4% in group 2, P = 0.082) underwent CA of AF. A centralized follow-up was obtained in 4,347 patients by the Institute for Myocardial Infarction Research (IHF, Ludwigshafen). There was a significant difference between periprocedural stroke rates in the elderly versus the younger cohort (1.3% vs. 0.1%, P < 0.01). In-hospital severe nonfatal complications did not differ significantly between the groups (4.4% vs. 2.7%, P = 0.14). Other procedure-related, in-hospital complications were not significantly different. After a mean follow-up of 472 ± 99 days (group 1) and 477 ± 94 days (group 2), no differences were found in complication rates. CONCLUSION: CA of AF in patients ≥75 years is associated with higher in-hospital stroke rates. In a 1-year follow-up, complication rates do not differ between the groups.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía , Accidente Cerebrovascular/etiología , Potenciales de Acción , Factores de Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Supervivencia sin Enfermedad , Femenino , Alemania , Frecuencia Cardíaca , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
18.
J Cardiovasc Electrophysiol ; 27(10): 1139-1150, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27325527

RESUMEN

INTRODUCTION: Conventional mapping of complex atrial tachycardias (ATs) can be challenging. Thus, we evaluated feasibility and utility of a novel, ultra high-density 3D mapping approach to characterize and map AT in these cases. METHODS AND RESULTS: Overall, 21 patients (67.4 ± 7.6 years; male: 52.4%, 1.9 ± 1.4 previous ablation procedures) with documented AT referred to our center underwent catheter ablation including ultra high-density mapping using a novel 64-electrode mini-basket catheter and an adjunctive 3D mapping system. A total of 24 AT (20 left atrial, 4 right atrial AT) were analyzed in 19 cases. In 2 patients, map acquisition failed due to scarce local electrograms and unstable AT cycle length, respectively. Underlying mechanisms were focal (n = 3), as well as local (n = 8) and macro (n = 13) reentry tachycardias with a mean cycle length of 311.8 ± 67.7 milliseconds. The analysis of propagation waves, activation and voltage revealed complex activation patterns and allowed for the identification of critical sites of AT initiation or maintenance without the need for further mapping techniques. In all cases critical sites could be verified by successful consecutive ablation. Mean mapping time was 19.4 ± 7.6 minutes, mean number of mapping points was 19,217 ± 10,270. Radiofrequency application until first effect was 165.1 ± 374.2 seconds; total procedure time was 157.6 ± 51.4 minutes, fluoroscopy time 21.7 ± 13.8 minutes, and total radiofrequency duration 1,016 ± 951.9 seconds, respectively. No severe complications occurred. CONCLUSION: Ultra high-density mapping of complex AT is safe and feasible. Further, it enables detailed insight into AT mechanisms. Critical AT sites can be identified precisely in order to guide successful catheter ablation.


Asunto(s)
Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Potenciales de Acción , Anciano , Ablación por Catéter/efectos adversos , Electrocardiografía , Estudios de Factibilidad , Femenino , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Radiografía Intervencional , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
19.
J Cardiovasc Electrophysiol ; 26(10): 1075-80, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26183341

RESUMEN

INTRODUCTION: Permanent pulmonary vein isolation (PVI) remains an essential goal of ablation therapy in patients with atrial fibrillation. Aim of this study was the intraindividual comparison of unexcitability to pacing along the ablation line versus dormant conduction (DC) as additional procedural endpoints. METHODS: A total of 58 patients with paroxysmal atrial fibrillation (PAF) underwent PVI by circumferential ablation of ipsilateral pulmonary veins (PVs), followed by testing for DC by adenosine administration. Irrespective of the presence of DC, pacing along the ablation line for left atrium capture was performed and additional radio frequency energy applied if necessary. PVs with initial DC were retested after achieving unexcitability. RESULTS: PVI was achieved in 224 of 224 PVs. In 33 of 224 PVs (15%) DC was revealed. At 92 of 112 ablation lines (82%) sites of excitability were found. Three (9%) of the initial 33 PVs with DC showed further DC after achieving unexcitability at repeated testing. Thirty-two of 33 assumed areas of unmasked PV-LA reconduction as revealed by DC-testing showed a corresponding site of excitability on the ablation line. After a follow-up of 11.6 ± 3.4 months 79% of patients were free of arrhythmia. CONCLUSIONS: Pacing for unexcitability can safely identify potential sites of DC and even sites that would have not been detected by testing for DC. Unexcitability, therefore, serves as a suitable and safe procedural endpoint not only for patients with contraindications to adenosine administration. Our data suggest that adenosine may be expendable when achieving unexcitability along the ablation line.


Asunto(s)
Adenosina , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Monitoreo Intraoperatorio/métodos , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Electrocardiografía/efectos de los fármacos , Electrocardiografía/métodos , Femenino , Sistema de Conducción Cardíaco/efectos de los fármacos , Sistema de Conducción Cardíaco/cirugía , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/efectos de los fármacos , Recurrencia , Resultado del Tratamiento
20.
J Cardiovasc Electrophysiol ; 26(7): 747-53, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25807878

RESUMEN

INTRODUCTION: Recently, a new image integration module (IIM, CartoUnivu™ Module) has been introduced to combine and merge fluoroscopy images with 3-dimensional-(3D)-electroanatomical maps (Carto® 3 System) into an accurate 3D view. The aim of the study was to investigate the influence of IIM on the fluoroscopy exposure during pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) in a prospective randomized trial. METHODS AND RESULTS: Between June and November 2014, a total of 60 patients with PAF (73.3% male, 64.0 ± 9.2 years), who underwent PVI with the endpoint of unexcitability of the ablation line, were randomized to either a conventional 3D mapping system (Carto® 3 System) or to an additional IIM on the basis of an assumed reduction of fluoroscopy exposure by the use of IIM. There were no significant differences in baseline characteristics. The median ablation procedure time was identical in both groups (140.7 ± 27.8 minutes vs. 140.8 ± 39.5 minutes; P = 0.851). A significant decrease of mean fluoroscopy time from 11.9 ± 2.1 to 7.4 ± 2.6 minutes (P < 0.0006) and median fluoroscopy dose from 882.9 to 476.5 cGycm(2) (P < 0.001) was achieved. The main reduction of radiation could be realized during creation of the 3D-map. No major complications occurred during the procedures. After a median follow-up of 125.7 ± 45.6 days 80% of the patients were free from any atrial arrhythmias. CONCLUSION: CartoUnivu™ module easily integrates into the workflow of PVI with the endpoint of unexcitability of the ablation line without prolonging the procedure time. It is associated with a marked reduction in fluoroscopic dose when compared to a conventional 3D mapping system.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Sistema de Conducción Cardíaco/cirugía , Venas Pulmonares/cirugía , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Intervencional/métodos , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Estudios de Factibilidad , Femenino , Fluoroscopía , Alemania , Sistema de Conducción Cardíaco/diagnóstico por imagen , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Valor Predictivo de las Pruebas , Estudios Prospectivos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Flujo de Trabajo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA