Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Biomech Eng ; 146(8)2024 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-38270929

RESUMEN

Cervical remodeling is critical for a healthy pregnancy. Premature tissue changes can lead to preterm birth (PTB), and the absence of remodeling can lead to post-term birth, causing significant morbidity. Comprehensive characterization of cervical material properties is necessary to uncover the mechanisms behind abnormal cervical softening. Quantifying cervical material properties during gestation is challenging in humans. Thus, a nonhuman primate (NHP) model is employed for this study. In this study, cervical tissue samples were collected from Rhesus macaques before pregnancy and at three gestational time points. Indentation and tension mechanical tests were conducted, coupled with digital image correlation (DIC), constitutive material modeling, and inverse finite element analysis (IFEA) to characterize the equilibrium material response of the macaque cervix during pregnancy. Results show, as gestation progresses: (1) the cervical fiber network becomes more extensible (nonpregnant versus pregnant locking stretch: 2.03 ± 1.09 versus 2.99 ± 1.39) and less stiff (nonpregnant versus pregnant initial stiffness: 272 ± 252 kPa versus 43 ± 43 kPa); (2) the ground substance compressibility does not change much (nonpregnant versus pregnant bulk modulus: 1.37 ± 0.82 kPa versus 2.81 ± 2.81 kPa); (3) fiber network dispersion increases, moving from aligned to randomly oriented (nonpregnant versus pregnant concentration coefficient: 1.03 ± 0.46 versus 0.50 ± 0.20); and (4) the largest change in fiber stiffness and dispersion happen during the second trimester. These results, for the first time, reveal the remodeling process of a nonhuman primate cervix and its distinct regimes throughout the entire pregnancy.


Asunto(s)
Cuello del Útero , Nacimiento Prematuro , Animales , Femenino , Embarazo , Matriz Extracelular , Análisis de Elementos Finitos , Macaca mulatta
2.
J Biomech Eng ; 146(7)2024 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-38491978

RESUMEN

Birthing mechanics are poorly understood, though many injuries during childbirth are mechanical, like fetal and maternal tissue damage. Several biomechanical simulation models of parturition have been proposed to investigate birth, but many do not include the uterus. Additionally, most solid models rely on segmenting anatomical structures from clinical images to generate patient geometry, which can be time-consuming. This work presents two new parametric solid modeling methods for generating patient-specific, at-term uterine three-dimensional geometry. Building from an established method of modeling the sagittal uterine shape, this work improves the uterine coronal shape, especially where the fetal head joins the lower uterine wall. Solid models of the uterus and cervix were built from five at-term patients' magnetic resonance imaging (MRI) sets. Using anatomy measurements from MRI-segmented models, two parametric models were created-one that employs an averaged coronal uterine shape and one with multiple axial measurements of the coronal uterus. Through finite element analysis, the two new parametric methods were compared to the MRI-segmented high-fidelity method and a previously published elliptical low-fidelity method. A clear improvement in the at-term uterine shape was found using the two new parametric methods, and agreement in principal Lagrange strain directions was observed across all modeling methods. These methods provide an effective and efficient way to generate three-dimensional solid models of patient-specific maternal uterine anatomy, advancing possibilities for future research in computational birthing biomechanics.


Asunto(s)
Imagenología Tridimensional , Útero , Femenino , Humanos , Útero/diagnóstico por imagen , Imagen por Resonancia Magnética , Cuello del Útero , Simulación por Computador
3.
J Biomech Eng ; 146(11)2024 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-38766990

RESUMEN

During vaginal delivery, the delivery requires the fetal head to mold to accommodate the geometric constraints of the birth canal. Excessive molding can produce brain injuries and long-term sequelae. Understanding the loading of the fetal brain during the second stage of labor (fully dilated cervix, active pushing, and expulsion of fetus) could thus help predict the safety of the newborn during vaginal delivery. To this end, this study proposes a finite element model of the fetal head and maternal canal environment that is capable of predicting the stresses experienced by the fetal brain at the onset of the second phase of labor. Both fetal and maternal models were adapted from existing studies to represent the geometry of full-term pregnancy. Two fetal positions were compared: left-occiput-anterior and left-occiput-posterior. The results demonstrate that left-occiput-anterior position reduces the maternal tissue deformation, at the cost of higher stress in the fetal brain. In both cases, stress is concentrated underneath the sutures, though the location varies depending on the presentation. In summary, this study provides a patient-specific simulation platform for the study of vaginal delivery and its effect on both the fetal brain and maternal anatomy. Finally, it is suggested that such an approach has the potential to be used by obstetricians to support their decision-making processes through the simulation of various delivery scenarios.


Asunto(s)
Encéfalo , Análisis de Elementos Finitos , Segundo Periodo del Trabajo de Parto , Humanos , Femenino , Embarazo , Encéfalo/fisiología , Encéfalo/embriología , Segundo Periodo del Trabajo de Parto/fisiología , Feto/fisiología , Estrés Mecánico , Soporte de Peso , Fenómenos Biomecánicos
4.
J Biomech Eng ; 144(6)2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35348624

RESUMEN

Cervical remodeling is critical for a healthy pregnancy. The proper regulation of extracellular matrix (ECM) turnover leads to remodeling throughout gestation, transforming the tissue from a stiff material to a compliant, extensible, viscoelastic tissue prepared for delivery. Small leucine-rich proteoglycans (SLRPs) regulate structural fiber assembly in the cervical ECM and overall tissue material properties. To quantify the SLRPs' mechanical role in the cervix, whole cervix specimens from nonpregnant and late pregnant knockout mice of SLRPs, decorin and biglycan, were subjected to cyclic load-unload, ramp-hold, and load-to-failure mechanical tests. Further, a fiber composite material model, accounting for collagen fiber bundle waviness, was developed to describe the cervix's three-dimensional large deformation equilibrium behavior. In nonpregnant tissue, SLRP knockout cervices have the same equilibrium material properties as wild-type tissue. In contrast, the load-to-failure and ramp-hold tests reveal SLRPs impact rupture and time-dependent relaxation behavior. Loss of decorin in nonpregnant (NP) cervices results in inferior rupture properties. After extensive remodeling, cervical strength is similar between all genotypes, but the SLRP-deficient tissue has a diminished ability to dissipate stress during a ramp-hold. In mice with a combined loss of decorin and biglycan, the pregnant cervix loses its extensibility, compliance, and viscoelasticity. These results suggest that decorin and biglycan are necessary for crucial extensibility and viscoelastic material properties of a healthy, remodeled pregnant cervix.


Asunto(s)
Cuello del Útero , Matriz Extracelular , Animales , Biglicano/genética , Decorina/genética , Proteínas de la Matriz Extracelular/genética , Femenino , Ratones , Ratones Noqueados , Embarazo
5.
J Biomech Eng ; 141(9)2019 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-31374123

RESUMEN

The cervix is essential to a healthy pregnancy as it must bear the increasing load caused by the growing fetus. Preterm birth is suspected to be caused by the premature softening and mechanical failure of the cervix. The objective of this paper is to measure the anisotropic mechanical properties of human cervical tissue using indentation and video extensometry. The human cervix is a layered structure, where its thick stromal core contains preferentially aligned collagen fibers embedded in a soft ground substance. The fiber composite nature of the tissue provides resistance to the complex three-dimensional loading environment of pregnancy. In this work, we detail an indentation mechanical test to obtain the force and deformation response during loading which closely matches in vivo conditions. We postulate a constitutive material model to describe the equilibrium material behavior to ramp-hold indentation, and we use an inverse finite element method based on genetic algorithm (GA) optimization to determine best-fit material parameters. We report the material properties of human cervical slices taken at different anatomical locations from women of different obstetric backgrounds. In this cohort of patients, the anterior internal os (the area where the cervix meets the uterus) of the cervix is stiffer than the anterior external os (the area closest to the vagina). The anatomic anterior and posterior quadrants of cervical tissue are more anisotropic than the left and right quadrants. There is no significant difference in material properties between samples of different parities (number of pregnancies reaching viable gestation age).


Asunto(s)
Cuello del Útero/citología , Análisis de Elementos Finitos , Ensayo de Materiales , Fenómenos Mecánicos , Adulto , Anisotropía , Fenómenos Biomecánicos , Cuello del Útero/diagnóstico por imagen , Femenino , Humanos , Persona de Mediana Edad , Modelos Biológicos , Imagen Molecular , Estrés Mecánico
6.
Nano Lett ; 18(10): 6113-6120, 2018 10 10.
Artículo en Inglés | MEDLINE | ID: mdl-30169958

RESUMEN

Solid electrolytes are crucial for the development of solid state batteries. Among different types of solid electrolytes, poly(ethylene oxide) (PEO)-based polymer electrolytes have attracted extensive attention owing to their excellent flexibility and easiness for processing. However, their relatively low ionic conductivities and electrochemical instability above 4 V limit their applications in batteries with high energy density. Herein, we prepared poly(vinylidene fluoride) (PVDF) polymer electrolytes with an organic plasticizer, which possesses compatibility with 4 V cathode and high ionic conductivity (1.2 × 10-4 S/cm) at room temperature. We also revealed the importance of plasticizer content to the ionic conductivity. To address weak mechanical strength of the PVDF electrolyte with plasticizer, we introduced palygorskite ((Mg,Al)2Si4O10(OH)) nanowires as a new ceramic filler to form composite solid electrolytes (CPE), which greatly enhances both stiffness and toughness of PVDF-based polymer electrolyte. With 5 wt % of palygorskite nanowires, not only does the elastic modulus of PVDF CPE increase from 9.0 to 96 MPa but also its yield stress is enhanced by 200%. Moreover, numerical modeling uncovers that the strong nanowire-polymer interaction and cross-linking network of nanowires are responsible for such significant enhancement in mechanically robustness. The addition of 5% palygorskite nanowires also enhances transference number of Li+ from 0.21 to 0.54 due to interaction between palygorskite and ClO4- ions. We further demonstrate full cells based on Li(Ni1/3Mn1/3Co1/3)O2 (NMC111) cathode, PVDF/palygorskite CPE, and lithium anode, which can be cycled over 200 times at 0.3 C, with 97% capacity retention. Moreover, the PVDF matrix is much less flammable than PEO electrolytes. Our work illustrates that the PVDF/palygorskite CPE is a promising electrolyte for solid state batteries.

7.
Reproduction ; 156(1): 71-79, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29712877

RESUMEN

The cervix shortens and softens as its collagen microstructure remodels in preparation for birth. Altered cervical tissue collagen microstructure can contribute to a mechanically weak cervix and premature cervical dilation and delivery. To investigate the local microstructural changes associated with anatomic location and pregnancy, we used second-harmonic generation microscopy to quantify the orientation and spatial distribution of collagen throughout cervical tissue from 4 pregnant and 14 non-pregnant women. Across patients, the alignment and concentration of collagen within the cervix was more variable near the internal os and less variable near the external os. Across anatomic locations, the spatial distribution of collagen within a radial zone adjacent to the inner canal of the cervix was more homogeneous than that of a region comprising the middle and outer radial zones. Two regions with different collagen distribution characteristics were found. The anterior and posterior sections in the outer radial zone were characterized by greater spatial heterogeneity of collagen than that of the rest of the sections. Our findings suggest that the microstructural alignment and distribution of collagen varies with anatomic location within the human cervix. These observed differences in collagen microstructural alignment may reflect local anatomic differences in cervical mechanical loading and function. Our study deepens the understanding of specific microstructural cervical changes in pregnancy and informs investigations of potential mechanisms for normal and premature cervical remodeling.


Asunto(s)
Cuello del Útero/diagnóstico por imagen , Cuello del Útero/metabolismo , Colágeno/metabolismo , Adulto , Femenino , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Nacimiento Prematuro , Tomografía de Coherencia Óptica , Adulto Joven
8.
J Biomech Eng ; 139(5)2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28303276

RESUMEN

Preterm birth is the leading cause of childhood mortality and can lead to health risks in survivors. The mechanical functions of the uterus, fetal membranes, and cervix have dynamic roles to protect the fetus during gestation. To understand their mechanical function and relation to preterm birth, we built a three-dimensional parameterized finite element model of pregnancy. This model is generated by an automated procedure that is informed by maternal ultrasound measurements. A baseline model at 25 weeks of gestation was characterized, and to visualize the impact of cervical structural parameters on tissue stretch, we evaluated the model sensitivity to (1) anterior uterocervical angle, (2) cervical length, (3) posterior cervical offset, and (4) cervical stiffness. We found that cervical tissue stretching is minimal when the cervical canal is aligned with the longitudinal uterine axis, and a softer cervix is more sensitive to changes in the geometric variables tested.


Asunto(s)
Análisis de Elementos Finitos , Fenómenos Mecánicos , Ultrasonografía , Adulto , Fenómenos Biomecánicos , Cuello del Útero/anatomía & histología , Cuello del Útero/diagnóstico por imagen , Femenino , Humanos , Embarazo , Útero/anatomía & histología , Útero/diagnóstico por imagen
9.
Am J Obstet Gynecol ; 215(4): 478.e1-478.e11, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27166013

RESUMEN

BACKGROUND: Premature cervical remodeling resulting in spontaneous preterm birth may begin with premature failure or relaxation at the internal os (termed "funneling"). To date, we do not understand why the internal os fails or why funneling occurs in some cases of premature cervical remodeling. Although the human cervix is thought to be mostly collagen with minimal cellular content, cervical smooth muscle cells are present in the cervix and can cause cervical tissue contractility. OBJECTIVE: To understand why the internal os relaxes or why funneling occurs in some cases of premature cervical remodeling, we sought to evaluate cervical smooth muscle cell content and distribution throughout human cervix and correlate if cervical smooth muscle organization influences regional cervical tissue contractility. STUDY DESIGN: Using institutional review board-approved protocols, nonpregnant women <50 years old undergoing hysterectomy for benign indications were consented. Cervical tissue from the internal and external os were immunostained for smooth muscle cell markers (α-smooth muscle actin, smooth muscle protein 22 calponin) and contraction-associated proteins (connexin 43, cyclooxygenase-2, oxytocin receptor). To evaluate cervical smooth muscle cell morphology throughout the entire cervix, whole cervical slices were obtained from the internal os, midcervix, and external os and immunostained with smooth muscle actin. To correlate tissue structure with function, whole slices from the internal and external os were stimulated to contract with 1 µmol/L of oxytocin in organ baths. In separate samples, we tested if the cervix responds to a common tocolytic, nifedipine. Cervical slices from the internal os were treated with oxytocin alone or oxytocin + increasing doses of nifedipine to generate a dose response and half maximal inhibitory concentration. Student t test was used where appropriate. RESULTS: Cervical tissue was collected from 41 women. Immunohistochemistry showed cervical smooth muscle cells at the internal and external os expressed mature smooth muscle cell markers and contraction-associated proteins. The cervix exhibited a gradient of cervical smooth muscle cells. The area of the internal os contained 50-60% cervical smooth muscle cells that were circumferentially organized in the periphery of the stroma, which may resemble a sphincter-like pattern. The external os contained approximately 10% cervical smooth muscle cells that were randomly scattered in the tissue. In organ bath studies, oxytocin stimulated the internal os to contract with more than double the force of the external os (1341 ± 693 vs 523 ± 536 integrated grams × seconds, respectively, P = .009). Nifedipine significantly decreased cervical tissue muscle force compared to timed vehicle control (oxytocin alone) at doses of 10(-5) mol/L (vehicle 47% ± 15% vs oxytocin + nifedipine 24% ± 16%, P = .007), 10(-4) mol/L (vehicle 46% ± 16% vs oxytocin + nifedipine -4% ± 20%, P = .003), and 10(-3) mol/L (vehicle 42% ± 14% vs oxytocin + nifedipine -15% ± 18%, P = .0006). The half maximal inhibitory concentration for nifedipine was 1.35 × 10(-5) mol/L. CONCLUSION: Our findings suggest a new paradigm for cervical tissue morphology-one that includes the possibility of a specialized sphincter at the internal os. This new paradigm introduces novel avenues to further investigate potential mechanisms of normal and premature cervical remodeling.


Asunto(s)
Cuello del Útero/citología , Miocitos del Músculo Liso/fisiología , Adulto , Cuello del Útero/efectos de los fármacos , Cuello del Útero/fisiopatología , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Inmunohistoquímica , Persona de Mediana Edad , Miocitos del Músculo Liso/efectos de los fármacos , Miocitos del Músculo Liso/patología , Nifedipino/farmacología , Oxitócicos/farmacología , Oxitocina/farmacología , Nacimiento Prematuro/etiología , Nacimiento Prematuro/fisiopatología , Tocolíticos/farmacología , Contracción Uterina/efectos de los fármacos
10.
Am J Obstet Gynecol ; 212(3): 321.e1-8, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25281365

RESUMEN

OBJECTIVE: The mechanical strength of the cervix relies on the cross-linking of the tissue's collagen network. Clinically, the internal os is functionally distinct from the external os. We sought to detect specific collagen cross-links in human cervical tissue and determine whether cross-link profiles were similar at the internal and external os. STUDY DESIGN: Transverse slices of cervical tissue were obtained at the internal and external os from 13 nonpregnant, premenopausal women undergoing a benign hysterectomy. To understand how cross-links were distributed throughout the entire cervix and at the internal and external os, biopsies were obtained from 3 circumferential zones in 4 quadrants from each slice. Biopsies were pulverized, lyophilized, reduced with sodium borohydride, hydrolyzed with hydrochloric acid, and reconstituted in heptafluorobutyric acid buffer. Hydroxyproline was measured by ultraperformance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-ESI-MS/MS), converted to total collagen, and normalized by dry weight. Collagen cross-links pyridinoline (PYD), deoxypyridinoline (DPD), dihydroxylysinonorleucine (DHLNL), and the nonenzymatic advanced glycation end product pentosidine (PEN) were measured by UPLC-ESI-MS/MS and reported as cross-link density ratio (cross-link/total collagen). Generalized estimated equation analysis was used to compare results between the internal and external os and to compare quadrants and zones within slices from the internal and external os to determine if cross-link profiles were similar. RESULTS: A total of 592 samples from 13 patients were analyzed. Collagen cross-links are detectable in the human cervix by UPLC-ESI-MS/MS. When comparing all samples from the internal and external os, similar levels of collagen content, PYD, DHLNL, and DPD were found, but PEN density was higher at the external os (0.005 vs 0.004, P = .001). When comparing all internal os samples, significant heterogeneity was found in collagen content and cross-link densities across zones and quadrants. The external os exhibited heterogeneity only across zones. CONCLUSION: Collagen cross-links (PYD, DPD, DHLNL, and PEN) are detectable by UPLC-ESI-MS/MS in the human cervix. The internal os exhibits significant collagen cross-link heterogeneity compared with the external os. Further studies are needed to evaluate how collagen cross-link heterogeneity correlates to the mechanical strength and function of the human cervix.


Asunto(s)
Cuello del Útero/ultraestructura , Colágeno/química , Adulto , Aminoácidos/química , Arginina/análogos & derivados , Arginina/química , Femenino , Humanos , Modelos Lineales , Lisina/análogos & derivados , Lisina/química , Persona de Mediana Edad , Premenopausia , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masas en Tándem
11.
J Biomech Eng ; 136(2): 021017, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24390076

RESUMEN

The remodeling of the cervix from a rigid barrier into a compliant structure, which dilates to allow for delivery, is a critical process for a successful pregnancy. Changes in the mechanical properties of cervical tissue during remodeling are hypothesized to be related to the types of collagen crosslinks within the tissue. To further understand normal and abnormal cervical remodeling, we quantify the material properties and collagen crosslink density of cervical tissue throughout pregnancy from normal wild-type and Anthrax Toxin Receptor 2 knockout (Antxr2-/-) mice. Antxr2-/- females are known to have a parturition defect, in part, due to an excessive accumulation of extracellular matrix proteins in the cervix, particularly collagen. In this study, we determined the mechanical properties in gestation-timed cervical samples by osmotic loading and measured the density of mature collagen crosslink, pyridinoline (PYD), by liquid chromatography tandem mass spectrometry (LC-MSMS). The equilibrium material response of the tissue to loading was investigated using a hyperelastic material model where the stresses in the material are balanced by the osmotic swelling tendencies of the glycosaminoglycans and the tensile restoring forces of a randomly-oriented crosslinked collagen fiber network. This study shows that the swelling response of the cervical tissue increased with decreasing PYD density in normal remodeling. In the Antxr2-/- mice, there was no significant increase in swelling volume or significant decrease in crosslink density with advancing gestation. By comparing the ECM-mechanical response relationships in normal and disrupted parturition mouse models this study shows that a reduction of collagen crosslink density is related to cervical softening and contributes to the cervical remodeling process.


Asunto(s)
Cuello del Útero/fisiología , Matriz Extracelular/metabolismo , Colágenos Fibrilares/metabolismo , Mecanotransducción Celular/fisiología , Modelos Biológicos , Parto/fisiología , Embarazo/fisiología , Adaptación Fisiológica/fisiología , Animales , Simulación por Computador , Módulo de Elasticidad/fisiología , Femenino , Dureza/fisiología , Humanos , Ratones , Ratones Noqueados , Receptores de Péptidos/genética , Viscosidad
12.
bioRxiv ; 2024 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-38076933

RESUMEN

Uterine rupture is an intrinsically biomechanical process associated with high maternal and fetal mortality. A previous Cesarean section (C-section) is the main risk factor for uterine rupture in a subsequent pregnancy due to tissue failure at the scar region. Finite element modeling of the uterus and scar tissue presents a promising method to further understand and predict uterine ruptures. Using patient dimensions of an at-term uterus, a C-section scar was modeled with an applied intrauterine pressure to study how scars affect uterine stress. The scar positioning and uterine thickness were varied, and a defect was incorporated into the scar region. The modeled stress distributions confirmed clinical observations as the increased regions of stress due to scar positioning, thinning of the uterine walls, and the presence of a defect are consistent with clinical observations of features that increase the risk of uterine rupture.

13.
J Mech Behav Biomed Mater ; 151: 106348, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38198930

RESUMEN

The uterus has critical biomechanical functions in pregnancy and undergoes dramatic material growth and remodeling from implantation to parturition. The intrinsic material properties of the human uterus and how they evolve in pregnancy are poorly understood. To address this knowledge gap and assess the heterogeneity of these tissues, the time-dependent material properties of all human uterine layers were measured with nanoindentation. The endometrium-decidua layer was found to be the least stiff, most viscous, and least permeable layer of the human uterus in nonpregnant and third-trimester pregnant tissues. In pregnancy, the endometrium-decidua becomes stiffer and less viscous with no material property changes observed in the myometrium or perimetrium. Additionally, uterine material properties did not significantly differ between third-trimester pregnant tissues with and without placenta accreta. The foundational data generated by this study will facilitate the development of physiologically accurate models of the human uterus to investigate gynecologic and obstetric disorders.


Asunto(s)
Decidua , Placenta , Embarazo , Humanos , Femenino , Útero , Miometrio
14.
J Mech Behav Biomed Mater ; 154: 106509, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38518513

RESUMEN

Gelatin methacryloyl (GelMA) hydrogels are widely used for a variety of tissue engineering applications. The properties of gelatin can affect the mechanical properties of gelatin gels; however, the role of gelatin properties such as bloom strength on GelMA hydrogels has not yet been explored. Bloom strength is a food industry standard for describing the quality of gelatin, where higher bloom strength is associated with higher gelatin molecular weight. Here, we evaluate the role of bloom strength on GelMA hydrogel mechanical properties. We determined that both bloom strength of gelatin and weight percent of GelMA influenced both stiffness and viscoelastic ratio; however, only bloom strength affected diffusivity, permeability, and pore size. With this library of GelMA hydrogels of varying properties, we then encapsulated Swan71 trophoblast spheroids in these hydrogel variants to assess how bloom strength affects trophoblast spheroid morphology. Overall, we observed a decreasing trend of spheroid area and Feret diameter as bloom strength increased. In identifying clear relationships between bloom strength, hydrogel mechanical properties, and trophoblast spheroid morphology, we demonstrate that bloom strength should considered when designing tissue engineered constructs.


Asunto(s)
Gelatina , Andamios del Tejido , Hidrogeles , Ingeniería de Tejidos , Metacrilatos
15.
Artículo en Inglés | MEDLINE | ID: mdl-38758337

RESUMEN

Successful pregnancy highly depends on the complex interaction between the uterine body, cervix, and fetal membrane. This interaction is synchronized, usually following a specific sequence in normal vaginal deliveries: (1) cervical ripening, (2) uterine contractions, and (3) rupture of fetal membrane. The complex interaction between the cervix, fetal membrane, and uterine contractions before the onset of labor is investigated using a complete third-trimester gravid model of the uterus, cervix, fetal membrane, and abdomen. Through a series of numerical simulations, we investigate the mechanical impact of (i) initial cervical shape, (ii) cervical stiffness, (iii) cervical contractions, and (iv) intrauterine pressure. The findings of this work reveal several key observations: (i) maximum principal stress values in the cervix decrease in more dilated, shorter, and softer cervices; (ii) reduced cervical stiffness produces increased cervical dilation, larger cervical opening, and decreased cervical length; (iii) the initial cervical shape impacts final cervical dimensions; (iv) cervical contractions increase the maximum principal stress values and change the stress distributions; (v) cervical contractions potentiate cervical shortening and dilation; (vi) larger intrauterine pressure (IUP) causes considerably larger stress values and cervical opening, larger dilation, and smaller cervical length; and (vii) the biaxial strength of the fetal membrane is only surpassed in the cases of the (1) shortest and most dilated initial cervical geometry and (2) larger IUP.

16.
bioRxiv ; 2024 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-38712283

RESUMEN

A successful pregnancy relies on the proper cellular, biochemical, and mechanical functions of the uterus. A comprehensive understanding of uterine mechanical properties during pregnancy is key to understanding different gynecological and obstetric disorders such as preterm birth, placenta accreta, leiomyoma, and endometriosis. This study sought to characterize the macro-scale equilibrium material behaviors of the human uterus in non-pregnancy and late pregnancy under both compressive and tensile loading. Fifty human uterine specimens from 16 patients (8 nonpregnant [NP] and 8 pregnant [PG]) were tested using spherical indentation and uniaxial tension coupled with digital image correlation (DIC). A three-level incremental load-hold protocol was applied to both tests. A microstructurally-inspired material model considering fiber architecture was applied to this dataset. Inverse finite element analysis (IFEA) was then performed to generate a single set of mechanical parameters to describe compressive and tensile behaviors. The freeze-thaw effect on uterine macro mechanical properties was also evaluated. PG tissue exhibits decreased overall stiffness and increased fiber network extensibility compared to NP uterine tissue. Under indentation, ground substance compressibility was similar between NP and PG uterine tissue. In tension, the fiber network of the PG uterus was found to be more extensible and dispersed than in nonpregnancy. Lastly, a single freeze-thaw cycle did not systematically alter the macro-scale material behavior of the human uterus.

17.
Sci Rep ; 14(1): 586, 2024 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-38182631

RESUMEN

Mammalian pregnancy requires gradual yet extreme remodeling of the reproductive organs to support the growth of the embryos and their birth. After delivery, the reproductive organs return to their non-pregnant state. As pregnancy has traditionally been understudied, there are many unknowns pertaining to the mechanisms behind this remarkable remodeling and repair process which, when not successful, can lead to pregnancy-related complications such as maternal trauma, pre-term birth, and pelvic floor disorders. This study presents the first longitudinal imaging data that focuses on revealing anatomical alterations of the vagina, cervix, and uterine horns during pregnancy and postpartum using the mouse model. By utilizing advanced magnetic resonance imaging (MRI) technology, T1-weighted and T2-weighted images of the reproductive organs of three mice in their in vivo environment were collected at five time points: non-pregnant, mid-pregnant (gestation day: 9-10), late pregnant (gestation day: 16-17), postpartum (24-72 h after delivery) and three weeks postpartum. Measurements of the vagina, cervix, and uterine horns were taken by analyzing MRI segmentations of these organs. The cross-sectional diameter, length, and volume of the vagina increased in late pregnancy and then returned to non-pregnant values three weeks after delivery. The cross-sectional diameter of the cervix decreased at mid-pregnancy before increasing in late pregnancy. The volume of the cervix peaked at late pregnancy before shortening by 24-72 h postpartum. As expected, the uterus increased in cross-sectional diameter, length, and volume during pregnancy. The uterine horns decreased in size postpartum, ultimately returning to their average non-pregnant size three weeks postpartum. The newly developed methods for acquiring longitudinal in vivo MRI scans of the murine reproductive system can be extended to future studies that evaluate functional and morphological alterations of this system due to pathologies, interventions, and treatments.


Asunto(s)
Imagen por Resonancia Magnética , Útero , Femenino , Humanos , Embarazo , Animales , Ratones , Útero/diagnóstico por imagen , Proyectos de Investigación , Vagina/diagnóstico por imagen , Periodo Posparto , Mamíferos
18.
J Mech Behav Biomed Mater ; 150: 106344, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38160642

RESUMEN

The fetal membranes are an essential mechanical structure for pregnancy, protecting the developing fetus in an amniotic fluid environment and rupturing before birth. In cooperation with the cervix and the uterus, the fetal membranes support the mechanical loads of pregnancy. Structurally, the fetal membranes comprise two main layers: the amnion and the chorion. The mechanical characterization of each layer is crucial to understanding how each layer contributes to the structural performance of the whole membrane. The in-vivo mechanical loading of the fetal membranes and the amount of tissue stress generated in each layer throughout gestation remains poorly understood, as it is difficult to perform direct measurements on pregnant patients. Finite element analysis of pregnancy offers a computational method to explore how anatomical and tissue remodeling factors influence the load-sharing of the uterus, cervix, and fetal membranes. To aid in the formulation of such computational models of pregnancy, this work develops a fiber-based multilayer fetal membrane model that captures its response to previously published bulge inflation loading data. First, material models for the amnion, chorion, and maternal decidua are formulated, informed, and validated by published data. Then, the behavior of the fetal membrane as a layered structure was analyzed, focusing on the respective stress distribution and thickness variation in each layer. The layered computational model captures the overall behavior of the fetal membranes, with the amnion being the mechanically dominant layer. The inclusion of fibers in the amnion material model is an important factor in obtaining reliable fetal membrane behavior according to the experimental dataset. These results highlight the potential of this layered model to be integrated into larger biomechanical models of the gravid uterus and cervix to study the mechanical mechanisms of preterm birth.


Asunto(s)
Nacimiento Prematuro , Recién Nacido , Embarazo , Femenino , Humanos , Membranas Extraembrionarias , Amnios , Feto , Pruebas Mecánicas
19.
bioRxiv ; 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38746471

RESUMEN

The coordinated biomechanical performance, such as uterine stretch and cervical barrier function, within maternal reproductive tissues facilitates healthy human pregnancy and birth. Quantifying normal biomechanical function and detecting potentially detrimental biomechanical dysfunction (e.g., cervical insufficiency, uterine overdistention, premature rupture of membranes) is difficult, largely due to minimal data on the shape and size of maternal anatomy and material properties of tissue across gestation. This study quantitates key structural features of human pregnancy to fill this knowledge gap and facilitate three-dimensional modeling for biomechanical pregnancy simulations to deeply explore pregnancy and childbirth. These measurements include the longitudinal assessment of uterine and cervical dimensions, fetal weight, and cervical stiffness in 47 low-risk pregnancies at four time points during gestation (late first, middle second, late second, and middle third trimesters). The uterine and cervical size were measured via 2-dimensional ultrasound, and cervical stiffness was measured via cervical aspiration. Trends in uterine and cervical measurements were assessed as time-course slopes across pregnancy and between gestational time points, accounting for specific participants. Patient-specific computational solid models of the uterus and cervix, generated from the ultrasonic measurements, were used to estimate deformed uterocervical volume. Results show that for this low-risk cohort, the uterus grows fastest in the inferior-superior direction from the late first to middle second trimester and fastest in the anterior-posterior and left-right direction between the middle and late second trimester. Contemporaneously, the cervix softens and shortens. It softens fastest from the late first to the middle second trimester and shortens fastest between the late second and middle third trimester. Alongside the fetal weight estimated from ultrasonic measurements, this work presents holistic maternal and fetal patient-specific biomechanical measurements across gestation.

20.
J Biomech Eng ; 135(2): 021024, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23445069

RESUMEN

The mechanical integrity of the uterine cervix is critical for a pregnancy to successfully reach full term. It must be strong to retain the fetus throughout gestation and then undergo a remodeling and softening process before labor for delivery of the fetus. It is believed that cervical insufficiency (CI), a condition in pregnancy resulting in preterm birth (PTB), is related to a cervix with compromised mechanical strength which cannot resist deformation caused by external forces generated by the growing fetus. Such PTBs are responsible for infant developmental problems and in severe cases infant mortality. To understand the etiologies of CI, our overall research goal is to investigate the mechanical behavior of the cervix. Permeability is a mechanical property of hydrated collagenous tissues that dictates the time-dependent response of the tissue to mechanical loading. The goal of this study was to design a novel soft tissue permeability testing device and to present direct hydraulic permeability measurements of excised nonpregnant (NP) and pregnant (PG) human cervical tissue from women with different obstetric histories. Results of hydraulic permeability testing indicate repeatability for specimens from single patients, with an order of magnitude separating the NP and PG group means (2.1 ± 1.4×10(-14) and 3.2 ± 4.8×10(-13)m(4)/N[middle dot]s, respectively), and large variability within the NP and PG sample groups. Differences were found between samples with similar obstetric histories, supporting the view that medical history may not be a good predictor of permeability (and therefore mechanical behavior) and highlighting the need for patient-specific measurements of cervical mechanical properties. The permeability measurements from this study will be used in future work to model the constitutive material behavior of cervical tissue and to develop in vivo diagnostic tools to stage the progression of labor.


Asunto(s)
Cuello del Útero/citología , Ensayo de Materiales/métodos , Adulto , Fenómenos Biomecánicos , Cuello del Útero/metabolismo , Femenino , Humanos , Persona de Mediana Edad , Permeabilidad , Embarazo , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA