Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Chron Respir Dis ; 20: 14799731231198865, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37612250

RESUMEN

BACKGROUND: Respiratory rate (RR) is used for the diagnosis and management of medical conditions and can predict clinical changes. Heavy workload, understaffing, and errors related to poor recording make it underutilized. Wearable devices may facilitate its use. METHODS: RR measurements using a wearable photoplethysmography-based monitor were compared with medical grade devices in complementary clinical scenarios: Study one included a comparison to a capnograph in 35 healthy volunteers; Study two included a comparison to a ventilator monitor in 18 ventilated patients; and Study three included a comparison to capnograph in 92 COVID-19 patients with active pulmonary disease. Pearson's correlations and Bland-Altman analysis were used to assess the accuracy and agreement between the measurement techniques, including stratification for Body Mass Index (BMI) and skin tone. Statistical significance was set at p ≤ 0.05. RESULTS: High correlation was found in all studies (r = 0.991, 0.884, and 0.888, respectively, p < 0.001 for all). 95% LOA of ±2.3, 1.7-(-1.6), and ±3.9 with a bias of < 0.1 breaths per minute was found in Bland-Altman analysis in studies 1,2, and 3, respectively. In all, high accordance was found in all sub-groups. CONCLUSIONS: RR measurements using the wearable monitor were highly-correlated with medical-grade devices in various clinical settings. TRIAL REGISTRATION: ClinicalTrials.gov, https://clinicaltrials.gov/ct2/show/NCT03603860.


Asunto(s)
Frecuencia Respiratoria , Dispositivos Electrónicos Vestibles , Humanos , Índice de Masa Corporal , Monitoreo Fisiológico/métodos
2.
Rev Cardiovasc Med ; 23(1): 16, 2022 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-35092208

RESUMEN

Heart failure with reduced ejection fraction (HFrEF) is an increasing global pandemic affecting more than 30 million individuals worldwide. Importantly, HFrEF is frequently accompanied by the presence of cardiac and non-cardiac comorbidities that may greatly influence the management and prognosis of the disease. In this review article, we will focus on three important comorbidities in HFrEF; atrial fibrillation (AF), advanced renal disease, and elderly, which all have a paramount impact on progression of the disease, management strategies, and response to therapy. AF is very common in HFrEF and shares many risk factors. AF aggravates heart failure and contributes to HF-related adverse clinical outcomes; hence it requires special consideration in HFrEF management. The kidney function is largely affected by the reduced cardiac output developed in the setting of HFrEF, and the neurohormonal feedback effects create a complex interplay that pose challenges in the management of HFrEF when renal function is significantly impaired. Cardiorenal syndrome is a challenging sequela with increased morbidity and mortality thereby reflecting the delicate and complex balance between the heart and the kidney in HFrEF and renal failure conditions. Furthermore, patients with advanced renal failure have poor prognosis in the presence of HFrEF with limited treatment options. Finally, aging and frailty are important factors that influence treatment strategies in HFrEF with greater emphasis on tolerability and safety of the various HFrEF therapies in elderly individuals.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Insuficiencia Renal , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Humanos , Pronóstico , Volumen Sistólico
3.
Curr Opin Cardiol ; 36(2): 211-218, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33394706

RESUMEN

PURPOSE OF REVIEW: Despite numerous attempts, none of a wide variety of tested drugs achieved meaningful improvement in the outcomes of heart failure with preserved ejection fraction (HFpEF), making new therapeutic strategies a major unmet medical need. The medical device industry embraced the challenge, developing novel technologies directed to face specific aspects of the pathophysiology of HFpEF. This review focuses on some of the most promising technologies attaining meaningful clinical progress recently in the field of HFpEF therapy. RECENT FINDINGS: Implantable pulmonary artery pressure, monitoring for optimization of medical therapy, proved to be beneficial in heart failure admissions in a large postmarketing clinical study. Investigational devices, such as inter-atrial shunts and transvenous phrenic nerve stimulators for the treatment of central sleep apnea with Cheyne-Stokes breathing, are currently being evaluated in HFpEF cohorts in recent trials. SUMMARY: Device-based therapies for HFpEF demonstrated encouraging safety and efficacy results in various stages of the disease. Further efforts are needed to ensure that these devices will reach clinical use and contribute to the management of HFpEF patients.


Asunto(s)
Insuficiencia Cardíaca , Atrios Cardíacos , Insuficiencia Cardíaca/tratamiento farmacológico , Humanos , Volumen Sistólico
4.
Am J Physiol Cell Physiol ; 318(6): C1055-C1064, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-32130072

RESUMEN

Sphingolipids (SL) are a family of bioactive lipids and a major cellular membrane structural component. SLs include three main compounds: ceramide (Cer), sphingosine (Sp), and sphingosine-1-phosphate (S-1P), all of which have emerging roles in biological functions in cells, especially in the liver. They are under investigation in various liver diseases, including cirrhosis and end-stage liver disease. In this review, we provide an overview on the role of SLs in liver pathobiology and focus on their potential role in the development of hepatic fibrosis. We describe recent evidence and suggest SLs are a promising potential therapeutic target for the treatment of liver disease and fibrosis.


Asunto(s)
Cirrosis Hepática/metabolismo , Hígado/metabolismo , Esfingolípidos/metabolismo , Animales , Proliferación Celular , Inhibidores Enzimáticos/uso terapéutico , Matriz Extracelular/metabolismo , Matriz Extracelular/patología , Células Estrelladas Hepáticas/metabolismo , Células Estrelladas Hepáticas/patología , Humanos , Macrófagos del Hígado/metabolismo , Macrófagos del Hígado/patología , Hígado/efectos de los fármacos , Hígado/patología , Cirrosis Hepática/tratamiento farmacológico , Cirrosis Hepática/patología , Fosfotransferasas (Aceptor de Grupo Alcohol)/antagonistas & inhibidores , Fosfotransferasas (Aceptor de Grupo Alcohol)/metabolismo , Transducción de Señal
7.
Biomedicines ; 12(6)2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38927384

RESUMEN

Intradialytic hypotension (IDH) is a severe complication of hemodialysis (HD) with a significant impact on morbidity and mortality. In this study, we used a wearable device for the continuous monitoring of hemodynamic vitals to detect hemodynamic changes during HD and attempted to identify IDH. End-stage kidney disease patients were continuously monitored 15 min before starting the session and until 15 min after completion of the session, measuring heart rate (HR), noninvasive cuffless systolic and diastolic blood pressure (SBP and DBP), stroke volume (SV), cardiac output (CO), and systemic vascular resistance (SVR). Data were analyzed retrospectively and included comparing BP measured by the wearable devices (recorded continuously every 5 s) and the cuff-based devices. A total of 98 dialysis sessions were included in the final analysis, and IDH was identified in 22 sessions (22.5%). Both SBP and DBP were highly correlated (r > 0.62, p < 0.001 for all) between the wearable device and the cuff-based measurements. Based on the continuous monitoring, patients with IDH had earlier and more profound reductions in SBP and DBP during the HD treatment. In addition, nearly all of the advanced vitals differed between groups. Further studies should be conducted in order to fully understand the potential of noninvasive advanced continuous monitoring in the prediction and prevention of IDH events.

8.
Front Physiol ; 14: 1138647, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37064911

RESUMEN

Background: Currently-used tools for early recognition of clinical deterioration have high sensitivity, but with low specificity and are based on infrequent measurements. We aimed to develop a pre-symptomatic and real-time detection and warning tool for potential patients' deterioration based on multi-parameter real-time warning score (MPRT-WS). Methods: A total of more than 2 million measurements were collected, pooled, and analyzed from 521 participants, of which 361 were patients in general wards defined at high-risk for deterioration and 160 were healthy participants allocation as controls. The risk score stratification was based on cutoffs of multiple physiological parameters predefined by a panel of specialists, and included heart rate, blood oxygen saturation (SpO2), respiratory rate, cuffless systolic and diastolic blood pressure (SBP and DBP), body temperature, stroke volume (SV), cardiac output, and systemic vascular resistance (SVR), recorded every 5 min for a period of up to 72 h. The data was used to define the various risk levels of a real-time detection and warning tool, comparing it with the clinically-used National Early Warning Score (NEWS). Results: When comparing risk levels among patients using both tools, 92.6%, 6.1%, and 1.3% of the readings were defined as "Low", "Medium", and "High" risk with NEWS, and 92.9%, 6.4%, and 0.7%, respectively, with MPRT-WS (p = 0.863 between tools). Among the 39 patients that deteriorated, 30 patients received 'High' or 'Urgent' using the MPRT-WS (42.7 ± 49.1 h before they deteriorated), and only 6 received 'High' score using the NEWS. The main abnormal vitals for the MPRT-WS were SpO2, SBP, and SV for the "Urgent" risk level, DBP, SVR, and SBP for the "High" risk level, and DBP, SpO2, and SVR for the "Medium" risk level. Conclusion: As the new detection and warning tool is based on highly-frequent monitoring capabilities, it provides medical teams with timely alerts of pre-symptomatic and real-time deterioration.

9.
Biomed Pharmacother ; 161: 114334, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36905809

RESUMEN

INTRODUCTION: Diuretics are a mainstay therapy for congestive heart failure (CHF); however, over one-third of patients develop diuretic resistance. Second-generation artificial intelligence (AI) systems introduce variability into treatment regimens to overcome the compensatory mechanisms underlying the loss of effectiveness of diuretics. This open-labeled, proof-of-concept clinical trial sought to investigate the ability to improve diuretic resistance by implementing algorithm-controlled therapeutic regimens. METHODS: Ten CHF patients with diuretic resistance were enrolled in an open-labeled trial where the Altus Care™ app managed diuretics' dosage and administration times. The app provides a personalized therapeutic regimen creating variability in dosages and administration times within pre-defined ranges. Response to therapy was measured by the Kansas City Cardiomyopathy Questionnaire (KCCQ) score, 6-minute walk test (SMW), N-terminal pro-brain natriuretic peptide (NT-proBNP) levels, and renal function. RESULTS: The second-generation, AI-based, personalized regimen alleviated diuretic resistance. All evaluable patients demonstrated clinical improvement within ten weeks of intervention. A dose reduction (based on a three-week average before and last three weeks of intervention) was achieved in 7/10 patients (70 %, p = 0.042). The KCCQ score improved in 9/10 (90 %, p = 0.002), the SMW improved in 9/9 (100 %, p = 0.006), NT-proBNP was decreased in 7/10 (70 %, p = 0.02), and serum creatinine was decreased in 6/10 (60 %, p = 0.05). The intervention was associated with reduced number of emergency room visits and the number of CHF-associated hospitalizations. SUMMARY: The results support that the randomization of diuretic regimens guided by a second-generation personalized AI algorithm improves the response to diuretic therapy. Prospective controlled studies are needed to confirm these findings.


Asunto(s)
Diuréticos , Insuficiencia Cardíaca , Humanos , Inteligencia Artificial , Diuréticos/uso terapéutico , Estudios de Factibilidad , Fragmentos de Péptidos/uso terapéutico , Estudios Prospectivos
10.
Front Physiol ; 14: 1279314, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38033330

RESUMEN

Introduction: Body temperature is essential for diagnosing, managing, and following multiple medical conditions. There are several methods and devices to measure body temperature, but most do not allow continuous and prolonged measurement of body temperature. Noninvasive skin temperature sensor combined with a heat flux sensor, also known as the "double sensor" technique, is becoming a valuable and simple method for frequently monitoring body temperature. Methods: Body temperature measurements using the "double sensor" method in a wearable monitoring device were compared with oral and core body temperature measurements using medical grade thermometers, analyzing data from two prospective clinical trials of different clinical scenarios. One study included 45 hospitalized COVID-19 patients in which oral measurements were taken using a hand-held device, and the second included 18 post-cardiac surgery patients in which rectal measurements were taken using a rectal probe. Results: In study 1, Bland-Altman analysis showed a bias of -0.04°C [0.34-(-0.43)°C, 95% LOA] with a correlation of 99.4% (p < 0.001). In study 2, Bland-Altman analysis showed a bias of 0.0°C [0.27-(-0.28)°C, 95% LOA], and the correlation was 99.3% (p < 0.001). In both studies, stratifying patients based on BMI and skin tone showed high accordance in all sub-groups. Discussion: The wearable monitor showed high correlation with oral and core body temperature measurements in different clinical scenarios.

11.
Digit Health ; 9: 20552076231218885, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38053733

RESUMEN

Background: Recent technological developments enable big data-driven insights on diurnal changes. This study aimed to describe the trajectory of multiple and advanced parameters using a medical-grade wearable remote patient monitor. Methods: Parameters were monitored for 24 h in 256 ambulatory participants who kept living their normal life. Parameters included heart rate, blood pressure, stroke volume, cardiac index, systemic vascular resistance, blood oxygen saturation, and respiratory rate. Diurnal variations were evaluated, and analyses were stratified based on sex, age, and body mass index. Results: All parameters showed diurnal changes (p < 0.001). Females demonstrated higher heart rate and cardiac index with lower systemic vascular resistance. Obese participants had a higher blood pressure, and lower stroke volume and cardiac index. Systemic vascular resistance was higher among the elderly. Diurnal changes corresponded with awake-sleep hours and differed between sex, age, and body mass index groups. Conclusion: Wearable monitoring platforms could decipher hemodynamic changes in subgroups of individuals, and might help with efforts to provide personalized medicine, pre-symptomatic diagnosis and prevention, and drug development.

12.
Front Physiol ; 13: 911544, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35846008

RESUMEN

Vital signs obtained by photoplethysmography-based devices might be influenced by subcutaneous fat and skin color. This observational comparison study aimed to test the accuracy of blood pressure (BP) measurements between a photoplethysmography-based device and cuff-based BP device in ambulatory individuals, coming for a routine BP checkup. Systolic BP (SBP) and diastolic BP (DBP) measurements were stratified based on sex, BMI (<25; 25 ≤BMI<30; 30 ≤kg/m2), and skin color (types 1-3 and 4-6 by the Fitzpatrick scale). A total of 1548 measurements were analyzed. Correlations of SBP and DBP between the devices among males/females were between 0.914-0.987 (p < 0.001), and Bland-Altman analysis showed a bias of less than 0.5 mmHg for both sexes. Correlations of SBP and DBP between the devices among BMI groups were between 0.931-0.991 (p < 0.001), and Bland-Altman analysis showed a bias of less than 1 mmHg for all. Correlations of SBP and DBP between the devices among the skin color groups were between 0.936-0.983 (p < 0.001), and Bland-Altman analysis showed a bias of less than 1 mmHg for all. This study shows similar and high agreements between BP measurements obtained using a PPG-based non-invasive cuffless BP device and a cuff-based BP device across sex, BMI, and skin color groups.

13.
Crit Care Explor ; 4(2): e0624, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35128457

RESUMEN

OBJECTIVES: Cardiac output (CO) measurements in the ICU are usually based on invasive techniques, which are technically complex and associated with clinical complications. This study aimed to compare CO measurements obtained from a noninvasive photoplethysmography-based device to a pulse contour cardiac output device in ICU patients. DESIGN: Observational, prospective, comparative clinical trial. SETTING: Single-center general ICU. PATIENTS: Patients admitted to the general ICU monitored using a pulse contour cardiac output device as per the decision of the attending physician. INTERVENTIONS: Parallel monitoring of CO using a photoplethysmography-based chest patch device and pulse contour cardiac output while the medical team was blinded to the values obtained by the noninvasive device. MEASUREMENTS AND MAIN RESULTS: Seven patients (69 measurements) were included in the final analysis. Mean CO were 7.3 ± 2.0 L/m and 7.0 ± 1.5 L/m for thermodilution and photoplethysmography, respectively. Bland-Altman showed that the photoplethysmography has a bias of 0.3 L/m with -1.6 and 2.2 L/m 95% limit of agreement (LOA) and a bias of 2.4% with 95% LOA between -25.7% and 30.5% when calculating the percentage of difference from thermodilution. The values obtained by thermodilution and photoplethysmography were highly correlated (r = 0.906). CONCLUSIONS: The tested chest patch device offers a high accuracy for CO compared to data obtained by the pulse contour cardiac output and the thermodilution method in ICU patients. Such devices could offer advanced monitoring capabilities in a variety of clinical settings, without the complications of invasive devices.

14.
Sci Rep ; 12(1): 17132, 2022 10 12.
Artículo en Inglés | MEDLINE | ID: mdl-36224357

RESUMEN

Penetrating abdominal injury is a major cause of death in trauma. Sodium alginate hydrogel, a hemostatic agent, offers a platform for targeting both mechanical and biological injuries. The current study assessed the effect of Very Low Viscosity (high) G (VLVG) alginate following abdominal trauma in a swine model of penetrating abdominal injury. Seven anesthetized pigs were instrumented with invasive monitoring catheters and abdominal trauma was introduced by laparoscopic hepatectomy. Ten minutes after the induction of hypovolemic shock, three animals were intra-abdominally administered with VLVG alginate (study group) and four animals with saline (control group). During 8 h of continuous monitoring, various hemodynamic and biochemical variables were measured and liver biopsies for histological evaluation were taken. Hemodynamically, VLVG alginate-treated animals were more stable than controls, as reflected by their lower heart rate and higher blood pressure (p < 0.05 for both). They also had lower levels of liver enzymes and lactate, and less histopathological damage. We show that VLVG alginate might be a promising new agent for reducing penetrating intra-abdominal injury, with hemostatic and biocompatibility efficiency, and tissue preserving properties. Future effort of integrating it with a dispersal device may turn it into a valuable pre-hospital emergency tool to improve survival of trauma casualties.


Asunto(s)
Traumatismos Abdominales , Hemostáticos , Heridas Penetrantes , Traumatismos Abdominales/tratamiento farmacológico , Traumatismos Abdominales/cirugía , Alginatos , Animales , Estudios de Factibilidad , Hemostáticos/farmacología , Hemostáticos/uso terapéutico , Hidrogeles , Lactatos , Porcinos , Heridas Penetrantes/tratamiento farmacológico
15.
J Clin Med ; 12(1)2022 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-36614848

RESUMEN

There are no clear guidelines for diuretic administration in heart failure (HF), and reliable markers are needed to tailor treatment. Continuous monitoring of multiple advanced physiological parameters during diuresis may allow better differentiation of patients into subgroups according to their responses. In this study, 29 HF patients were monitored during outpatient intravenous diuresis, using a noninvasive wearable multi-parameter monitor. Analysis of changes in these parameters during the course of diuresis aimed to recognize subgroups with different response patterns. Parameters did not change significantly, however, subgroup analysis of the last quartile of treatment showed significant differences in cardiac output, cardiac index, stroke volume, pulse rate, and systemic vascular resistance according to gender, and in systolic blood pressure according to habitus. Changes in the last quartile could be differentiated using k-means, a technique of unsupervised machine learning. Moreover, patients' responses could be best clustered into four groups. Analysis of baseline parameters showed that two of the clusters differed by baseline parameters, body mass index, and diabetes status. To conclude, we show that physiological changes during diuresis in HF patients can be categorized into subgroups sharing similar response trends, making noninvasive monitoring a potential key to personalized treatment in HF.

16.
J Clin Med ; 10(19)2021 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-34640427

RESUMEN

Heart failure with reduced ejection fraction (HFrEF) is a clinical condition associated with cardiac contractility impairment. HFrEF is a significant public health issue with a high morbidity and mortality burden. Pathological left ventricular (LV) remodeling and progressive dilatation are hallmarks of HFrEF pathogenesis, ultimately leading to adverse clinical outcomes. Therefore, cardiac remodeling attenuation has become a treatment goal and a standard of care over the last three decades. Guideline-directed medical therapy mainly targeting the sympathetic nervous system and the renin-angiotensin-aldosterone system (RAAS) has led to improved survival and a reduction in HF hospitalization in this population. More recently, novel pharmacological therapies targeting other pathways implicated in the pathophysiology of HFrEF have emerged at an exciting rate, with landmark clinical trials demonstrating additive clinical benefits in patients with HFrEF. Among these novel therapies, angiotensin receptor-neprilysin inhibitors (ARNI), sodium-glucose cotransporter-2 inhibitors (SGLT2i), vericiguat (a novel oral guanylate cyclase stimulator), and omecamtiv mecarbil (a selective cardiac myosin activator) have shown improved clinical benefit when added to the traditional standard-of-care medical therapy in HFrEF. These new comprehensive data have led to a remarkable change in the medical therapy paradigm in the setting of HFrEF. This article will review the pivotal studies involving these novel agents and present a suggestive paradigm of pharmacological therapy representing the 2021 European Society of Cardiology (ESC) guidelines for the treatment of chronic HFrEF.

17.
J Clin Med ; 10(20)2021 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-34682813

RESUMEN

Despite significant advances in the management of heart failure (HF), further improvement in the outcome of this chronic and progressive disease is still considered a major unmet need. Recurrent hospitalizations due to decompensated HF frequently occur, resulting in increased morbidity and mortality rates. Past attempts at early detection of clinical deterioration were mainly based on monitoring of signs and symptoms of HF exacerbation, which have mostly given disappointing results. Extensive research of the pathophysiology of HF decompensation has indicated that hemodynamic alterations start days prior to clinical manifestation. Novel technologies aim to monitor these minute hemodynamic changes, allowing time for therapeutic interventions to prevent hemodynamic derangement and HF exacerbation. The latest noticeable advancements include assessment of lung fluid volume, wearable devices with integrated sensors, and microelectromechanical systems-based implantable devices for continuous measurement of cardiac filling pressures. This manuscript will review the rationale for monitoring HF patients and discuss previous and ongoing attempts to develop clinically meaningful monitoring devices to improve daily HF health care, with particular emphasis on the recent advances and clinical trials relevant to this evolving field.

18.
Front Med (Lausanne) ; 8: 693926, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34422859

RESUMEN

Background: Continuous blood pressure (BP) measurement in intensive care units is based on arterial line (AL) transducers, sometimes associated with clinical complications. Our objective was to evaluate continuous BP measurements obtained from a non-invasive, wireless photoplethysmography (PPG)-based device using two distinct configurations (wristwatch and chest-patch monitors) compared to an AL. Methods: In this prospective evaluation study, comparison of the PPG-based devices to the AL was conducted in 10 patients immediately following cardiac surgery. Pulse rate (PR), systolic BP (SBP), diastolic BP (DBP), and mean arterial pressure (MAP) were recorded using both the AL and the PPG-based devices simultaneously for an average of 432 ± 290 min starting immediately after cardiac surgery. Bland-Altman plots and Pearson's correlations were used to assess the accuracy and degree of agreement between techniques. Results: A total of ~4,000 data points were included in the final analysis. AL measurements for PR, SBP, DBP and MAP were significantly (p < 0.001) and strongly correlated with both the wristwatch (r = 0.99, r = 0.94, r = 0.93 and r = 0.96, respectively) and the chest-patch (r = 0.99, r = 0.95, r = 0.93 and r = 0.95, respectively) monitors. Both configurations showed a marginal bias of <1 mmHg for BP measurements and <1 beat/min for PR [95% limits of agreement -3,3 beat/min; BP measurements: (-6)-(-10), 6-10 mmHg] compared to AL measurements. Conclusion: The PPG-based devices offer a high level of accuracy for cardiac-related parameters compared to an AL in post-cardiac surgery patients. Such devices could provide advanced monitoring capabilities in a variety of clinical settings, including immediate post-operative and intensive care unit settings. Clinical Trial Registration:www.clinicaltrials.gov, NCT03603860.

19.
J Biophotonics ; 14(1): e202000329, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32888351

RESUMEN

Rupture of Abdominal aortic aneurysm (AAA) is among the 15 leading causes of death after age 65. Using high frequency ultrasound, we showed that photobiomodulation (PBM) prevents formation and progression of AAA in the angiotensin-II (Ang-II)-infused, apolipoprotein-e-deficient mouse model. In the current study we report that while challenge of porcine aortic Smooth Muscle Cells (SMCs) with Ang-II (1 µM) resulted in a marked decay in mitochondrial membrane potential (MitMP) vs non-challenged cells, treatment with PBM (continuous diode laser, 780 nm, 6.7 mW/cm2 , 5 minutes, 2 J/cm2 ) or pre-incubation with estrogen (50 nM, 1 hour) significantly attenuated this deterioration in MitMP. We also report that PBM and estrogen markedly affected porcine aortic SMC contraction and modified mitochondrial dispersion reflecting important influence on SMC function. These studies provide strong evidence of the important underlying role of mitochondria in the preventive effect of PBM on formation and progression of AAA and its reduced incidence and delayed onset in women.


Asunto(s)
Angiotensina II , Aneurisma de la Aorta Abdominal , Angiotensina II/farmacología , Animales , Apolipoproteínas E , Modelos Animales de Enfermedad , Estrógenos , Potencial de la Membrana Mitocondrial , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Miocitos del Músculo Liso , Porcinos
20.
Mil Med Res ; 8(1): 27, 2021 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-33894775

RESUMEN

BACKGROUND: Tension pneumothorax is one of the leading causes of preventable death on the battlefield. Current prehospital diagnosis relies on a subjective clinical impression complemented by a manual thoracic and respiratory examination. These techniques are not fully applicable in field conditions and on the battlefield, where situational and environmental factors may impair clinical capabilities. We aimed to assemble a device able to sample, analyze, and classify the unique acoustic signatures of pneumothorax and hemothorax. METHODS: Acoustic data was obtained with simultaneous use of two sensitive digital stethoscopes from the chest wall of an ex-vivo porcine model. Twelve second samples of acoustic data were obtained from the in-house assembled digital stethoscope system during mechanical ventilation. The thoracic cavity was injected with increasing volumes of 200, 400, 600, 800, and 1000 ml of air or saline to simulate pneumothorax and hemothorax, respectively. The data was analyzed using a multi-objective genetic algorithm that was used to develop an optimal mathematical detector through the process of artificial evolution, a cutting-edge approach in the artificial intelligence discipline. RESULTS: The in-house assembled dual digital stethoscope system and developed genetic algorithm achieved an accuracy, sensitivity and specificity ranging from 64 to 100%, 63 to 100%, and 63 to 100%, respectively, in classifying acoustic signal as associated with pneumothorax or hemothorax at fluid injection levels of 400 ml or more, and regardless of background noise. CONCLUSIONS: We present a novel, objective device for rapid diagnosis of potentially lethal thoracic injuries. With further optimization, such a device could provide real-time detection and monitoring of pneumothorax and hemothorax in battlefield conditions.


Asunto(s)
Inteligencia Artificial/normas , Auscultación/instrumentación , Hemoneumotórax/diagnóstico , Estetoscopios/normas , Animales , Inteligencia Artificial/tendencias , Auscultación/métodos , Auscultación/normas , Modelos Animales de Enfermedad , Estudios de Factibilidad , Hemoneumotórax/fisiopatología , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA