Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(2): 328-340, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38105441

RESUMEN

INTRODUCTION: The aim of the current study was to elucidated the reliable atrial fibrillation (AF) drivers identified by CARTOFINDER using OctaRay catheter. METHODS AND RESULTS: The reliability of focal and rotational activations identified by CARTOFINDER using OctaRay catheter was assessed by the sequential recordings in each site of both atrium before and after pulmonary vein isolation (PVI) in 10 persistent AF patients. The outcome measures were the reproducibility rate during the sequential recordings and the stability rate between pre- and post-PVI as reliable focal and rotational activations. The study results were compared with those under use of PentaRay catheter (N = 18). Total 68928 points of 360 sites in OctaRay group and 24 177 points of 311 sites in PentaRay were assessed. More focal activation sites were identified in OctaRay group than PentaRay group (7.9% vs. 5.7%, p < .001), although the reproducibility rate and the stability rate were significantly lower in OctaRay group (45.3% vs. 58.9%, p < .001; 11.2% vs. 28.4%, p < .001). Meanwhile, the prevalence of reproducible focal activation sites among overall points was comparable (3.6% vs. 3.3%, p = .08). Regarding rotational activation, more rotational activation sites were identified in OctaRay group (5.1% vs. 0.2%, p < .001), and the reproducibility rate and the stability rate were significantly higher in OctaRay group (45.2% and 12.5% vs. 0.0%, p < .001). Both reliable focal and rotational activation sites were characterized by significantly shorter AF-cycle length (CL) and higher repetition of focal and rotational activations during the recordings compared with the sites of non or unreliable focal and rotational activations. CONCLUSION: In CARTOFINDER, OctaRay catheter could identify reliable focal activation with high resolution and reliable rotational activation compared with PentaRay catheter. The repetitive focal and rotational activations with short AF-CL could be the potential target during ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Frecuencia Cardíaca , Reproducibilidad de los Resultados , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Catéteres , Venas Pulmonares/cirugía , Resultado del Tratamiento
2.
Circ J ; 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38719572

RESUMEN

BACKGROUND: Data on concomitant mitral regurgitation (MR) in patients with severe aortic stenosis (AS) are scarce.Methods and Results: We investigated the risk of concomitant MR in patients with severe AS in the CURRENT AS Registry-2 according to initial treatment strategy (transcatheter aortic valve implantation [TAVI], surgical aortic valve replacement [SAVR], or conservative). Among 3,365 patients with severe AS, 384 (11.4%) had moderate/severe MR (TAVI: n=126/1,148; SAVR: n=68/591; conservative: n=190/1,626). The cumulative 3-year incidence for death or heart failure (HF) hospitalization was significantly higher in the moderate/severe than no/mild MR group in the entire population (54.6% vs. 34.3%, respectively; P<0.001) and for each treatment strategy (TAVI: 45.0% vs. 31.8% [P=0.006]; SAVR: 31.9% vs. 18.7% [P<0.001]; conservative: 67.8% vs. 41.6% [P<0.001]). The higher adjusted risk of moderate/severe MR relative to no/mild MR for death or HF hospitalization was not significant in the entire population (hazard ratio [HR] 1.15; 95% confidence interval [CI] 0.95-1.39; P=0.15); however, the risk was significant in the SAVR (HR 1.92; 95% CI 1.04-3.56; P=0.04) and conservative (HR 1.30; 95% CI 1.02-1.67; P=0.04) groups, but not in the TAVI group (HR 1.03; 95% CI 0.70-1.52; P=0.86), despite no significant interaction (Pinteraction=0.37). CONCLUSIONS: Moderate/severe MR was associated with a higher risk for death or HF hospitalization in the initial SAVR and conservative strategies, while the association was less pronounced in the initial TAVI strategy.

3.
Ann Vasc Surg ; 100: 138-147, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38141967

RESUMEN

BACKGROUND: Prophylactic embolization of the inferior mesenteric artery (IMA) during endovascular aneurysm repair (EVAR) is recommended to prevent type 2 endoleak (T2EL). However, the impact of patent lumbar arteries (LAs) on T2ELs and aneurysm diameter has not been elucidated. METHODS: Fifty-seven consecutive patients who underwent EVAR at our institution between January 2013 and September 2022 and whose IMA had been occluded preoperatively or newly occluded postoperatively were included in the study. Predictive factors for aneurysm sac enlargement, sac shrinkage, and T2EL were investigated. RESULTS: T2ELs occurred in 22.8% of the patients. The 4-year cumulative incidence rates of sac enlargement and shrinkage were 6.7% and 64.6%, respectively. The number of postoperative patent LAs was identified as a risk factor for T2ELs (95% confidence interval [CI]: 1.54-12.7, P = 0.0065). The number of postoperative patent LAs was found to be a significant predictor of sac enlargement (adjusted hazard ratio [AHR] 3.15, 95% CI: 1.43-6.96, P = 0.0045) and shrinkage (AHR 0.63, 95% CI: 0.43-0.91, P = 0.014). CONCLUSIONS: The current study demonstrated that the number of postoperative patent LAs had a significant impact on the development of T2ELs and the change in aneurysm diameter in patients in whom the IMA was occluded after EVAR.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Embolización Terapéutica , Procedimientos Endovasculares , Humanos , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Reparación Endovascular de Aneurismas , Resultado del Tratamiento , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Aorta Abdominal/cirugía , Factores de Riesgo , Estudios Retrospectivos , Embolización Terapéutica/efectos adversos
4.
Circ J ; 87(2): 277-286, 2023 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-36351607

RESUMEN

BACKGROUND: There is a scarcity of studies comparing the clinical outcomes after percutaneous coronary intervention (PCI) for women and men stratified by the presentation of acute coronary syndromes (ACS) or stable coronary artery disease (CAD).Methods and Results: The study population included 26,316 patients who underwent PCI (ACS: n=11,119, stable CAD: n=15,197) from the CREDO-Kyoto PCI/CABG registry Cohort-2 and Cohort-3. The primary outcome was all-cause death. Among patients with ACS, women as compared with men were much older. Among patients with stable CAD, women were also older than men, but with smaller difference. The cumulative 5-year incidence of all-cause death was significantly higher in women than in men in the ACS group (26.2% and 17.9%, log rank P<0.001). In contrast, it was significantly lower in women than in men in the stable CAD group (14.2% and 15.8%, log rank P=0.005). After adjusting confounders, women as compared with men were associated with significantly lower long-term mortality risk with stable CAD but not with ACS (hazard ratio [HR]: 0.75, 95% confidence interval [CI]: 0.69-0.82, P<0.001, and HR: 0.92, 95% CI: 0.84-1.01, P=0.07, respectively). There was a significant interaction between the clinical presentation and the mortality risk of women relative to men (interaction P=0.002). CONCLUSIONS: Compared with men, women had significantly lower adjusted mortality risk after PCI among patients with stable CAD, but not among those with ACS.


Asunto(s)
Síndrome Coronario Agudo , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Femenino , Masculino , Puente de Arteria Coronaria/métodos , Estudios de Seguimiento , Intervención Coronaria Percutánea/métodos , Caracteres Sexuales , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/complicaciones , Síndrome Coronario Agudo/cirugía , Síndrome Coronario Agudo/complicaciones , Sistema de Registros
5.
Circ J ; 87(11): 1689-1702, 2023 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-36908119

RESUMEN

BACKGROUND: There is a paucity of data on the effect of optimal intravascular ultrasound (IVUS)-guided percutaneous coronary intervention (PCI) compared with standard PCI or coronary artery bypass grafting (CABG) in patients with multivessel disease.Methods and Results: The OPTIVUS-Complex PCI study multivessel cohort was a prospective multicenter single-arm study enrolling 1,021 patients undergoing multivessel PCI including the left anterior descending coronary artery using IVUS aiming to meet the prespecified criteria for optimal stent expansion. We conducted propensity score matching analyses between the OPTIVUS group and historical PCI or CABG control groups from the CREDO-Kyoto registry cohort-3 (1,565 and 899 patients) fulfilling the inclusion criteria for this study. The primary endpoint was a composite of death, myocardial infarction, stroke, or any coronary revascularization. In the propensity score-matched cohort (OPTIVUS vs. historical PCI control: 926 patients in each group; OPTIVUS vs. historical CABG control: 436 patients in each group), the cumulative 1-year incidence of the primary endpoint was significantly lower in the OPTIVUS group than in the historical PCI control group (10.4% vs. 23.3%; log-rank P<0.001) or the historical CABG control group (11.8% vs. 16.5%; log-rank P=0.02). CONCLUSIONS: IVUS-guided PCI targeting the OPTIVUS criteria combined with contemporary clinical practice was associated with superior clinical outcomes at 1 year compared with not only the historical PCI control, but also the historical CABG control.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Estudios de Seguimiento , Estudios Prospectivos , Resultado del Tratamiento , Sistema de Registros
6.
Circ J ; 86(11): 1769-1776, 2022 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-35444112

RESUMEN

BACKGROUND: There is scarce data evaluating the current practice pattern and clinical outcomes for patients with severe aortic stenosis (AS), including both those who underwent surgical aortic valve replacement (SAVR) or transcatheter aortic valve implantation (TAVI) and those who were managed conservatively in the TAVI era.Methods and Results: The Contemporary outcomes after sURgery and medical tREatmeNT in patients with severe Aortic Stenosis (CURRENT AS) Registry-2 is a prospective, physician-initiated, multicenter registry enrolling consecutive patients who were diagnosed with severe AS between April 2018 and December 2020 among 21 centers in Japan. The rationale for the prospective enrollment was to standardize the assessment of symptomatic status, echocardiographic evaluation, and other recommended diagnostic examinations such as computed tomography and measurement of B-type natriuretic peptide. Moreover, the schedule of clinical and echocardiographic follow up was prospectively defined and strongly recommended for patients who were managed conservatively. The entire study population consisted of 3,394 patients (mean age: 81.6 years and women: 60%). Etiology of AS was degenerative in 90% of patients. AS-related symptoms were present in 60% of patients; these were most often heart failure symptoms. The prevalence of high- and low-gradient AS was 58% and 42%, respectively, with classical and paradoxical low-flow low-gradient AS in 4.6% and 6.7%, respectively. CONCLUSIONS: The CURRENT AS Registry-2 might be large and meticulous enough to determine the appropriate timing of intervention for patients with severe AS in contemporary clinical practice.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Femenino , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Péptido Natriurético Encefálico , Estudios Prospectivos , Sistema de Registros , Factores de Riesgo , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Masculino
7.
Pacing Clin Electrophysiol ; 45(5): 688-695, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35415846

RESUMEN

BACKGROUND: ExTRa Mapping™ has developed to visualize rotational activation as atrial fibrillation (AF) drivers. The current study was sought to evaluate the instability of AF drivers by ExTRa Mapping™. METHODS: Variation of nonpassively activated ratio (%NP) among three-time repetitive recordings before and after pulmonary vein isolation (PVI) in left atrium was assessed in 26 persistent AF patients. The recoding time was set at 5 or 8 s for the respective patients. The outcome measures included %NP at each recording, mean value of the three-time recordings, and the instability index, which was defined as maximum difference per mean %NP × 100 (%). RESULTS: Total 683 sites 2049 recordings were assessed. Mean %NP was 33.3(23.3-42.7)%, and higher in sites with severe (≥50%) and patchy low voltage area than those without, but not in those with severe complex fractionated atrial electrogram area. There was significant correlation between actual and mean %NP (R = 0.86, P < .001), but maximum difference among the repetitive recordings was 16(10-24)%. The instability index of %NP was 55.9(30.9-83.6)%, and significantly lower at the recordings of 8 s compared with 5 s (50.6[28.6-78.4]% vs. 60.4[35.0-90.0]%, P = .004). Furthermore, it was higher at sites with lower reliability of the recordings. After PVI, mean %NP significantly decreased (28.7[18.3-36.7]% vs. 37.7[28.7-45.7]%, P < .001), but the instability index significantly increased compared with those before PVI (60.0[35.0-92.7]% vs. 48.9[29.1-75.0]%, P = .001). CONCLUSION: Rotational activation as AF drivers assessed by ExTRa Mapping™ is unstable, and repetitive and longer recording is required for the reliable assessment even after PVI.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Ablación por Catéter/efectos adversos , Técnicas Electrofisiológicas Cardíacas , Humanos , Venas Pulmonares/cirugía , Recurrencia , Reproducibilidad de los Resultados , Resultado del Tratamiento
8.
J Cardiovasc Electrophysiol ; 30(6): 926-933, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30912209

RESUMEN

LIMITATIONS OF THE ABLATION INDEX BACKGROUND: Ablation index (AI) is a novel marker of lesion quality from radiofrequency (RF) catheter ablation. However, AI reliability has not been fully validated by experimental data. The aim of the present study is to validate AI reliability for estimating lesion size using different settings for RF parameters: contact angle, power delivery, and contact force (CF). METHODS AND RESULTS: We evaluated the lesion size in porcine hearts (N = 108) after RF application at three different contact angles to the myocardium: perpendicular (90°), oblique (45°), and parallel (0°). At each angle, RF power at 25, 30, and 35 W was applied at target CF values of 5, 15, and 30 g as measured by the CF sensor to reach target AIs of 300, 400, 500, and 600. AI value was significantly correlated with lesion depth, width, and volume (R = 0.84, 0.82, and 0.87, respectively, all P < 0.001). Lesion depth decreased with smaller contact angles (45° and 0°). Furthermore, high-power RF energy (35 W) resulted in a significantly smaller lesion volume compared with standard-power energy (30 W). There were no significant differences in lesion size among CF settings. CONCLUSIONS: AI was strongly correlated with lesion depth, width, and volume, but only within a small range of contact angles and RF power delivery settings.


Asunto(s)
Catéteres Cardíacos , Ablación por Catéter/instrumentación , Ventrículos Cardíacos/cirugía , Miocardio/patología , Irrigación Terapéutica/instrumentación , Animales , Ventrículos Cardíacos/patología , Sus scrofa , Factores de Tiempo
9.
Pacing Clin Electrophysiol ; 42(6): 663-669, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30873619

RESUMEN

BACKGROUND: Electroanatomic voltage mapping (EAVM) of the left atrium (LA) with multielectrodes is usually acquired during sinus rhythm (SR), and the feasibility of EAVM during atrial fibrillation (AF) rhythm is unclear. METHODS: We performed EAVM of LA during both SR and AF rhythm in 44 patients undergoing catheter ablation for AF and validated the optimal cutoff value of low-voltage area (LVA) during AF rhythm for detecting LVA defined as bipolar voltages ≤0.5 mV during SR. RESULTS: In each session, mean 829 and 552 points were acquired by multielectrodes during SR and AF rhythm, respectively. Mean proportion of LVA was 4.9% among LA surface area of 276.2 cm2 . Differences of LVA proportions between SR and AF rhythm were 5.8% (P < 0.001), 4.2% (P < 0.001), 2.7% (P < 0.001), 1.2% (P = 0.01), and -0.5% (P = 0.17) at the cutoff value of 0.4, 0.35, 0.3, 0.25, and 0.2 mV during AF rhythm, respectively. There was a good correlation between LVA proportions during SR and AF rhythm with cutoff value of 0.2 mV (R = 0.88, P < 0.001) and 37 patients (84.1%) had the discrepancy of LVA proportions within 3%. Furthermore, there was no significant difference between LVA proportions at each segment of LA. The discrepancy was relatively large in patients with large LA dimension and LVA during SR. CONCLUSION: EAVM during AF rhythm was feasible and the optimal cutoff value of LVA was 0.2 mV for detecting LVA ≤ 0.5 mV during SR. However, the evidence is restricted to patients with relatively small LVA.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Anciano , Femenino , Humanos , Masculino
10.
Catheter Cardiovasc Interv ; 92(1): E9-E14, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-28940984

RESUMEN

OBJECTIVES: We developed a novel guidewire-integrated filter device with a handy-folding system (IFD: Inoue filter device). In vitro and in vivo studies were conducted to evaluate the feasibilityof the IFD. BACKGROUND: Although distal atheromatous and thrombotic embolizations remain unresolved critical issues during catheter interventions, distal protection devices are infrequently used partly because of reduced lower maneuverability. METHODS: In the in vitro experiment, we created an experimental circulation model composed of silicone latex tubes, a reservoir, and a roller pump. After the filter device was deployed in the tube, polystyrene fluorescent microspheres were injected and the capture rate was calculated. Ten trials were performed using the IFD and Spider FX. In the in vivo study, five independent operators deployed, and they retrieved the IFD in swine common iliac and internal carotid arteries. The procedural success rate as well as the delivery and retrieval time was evaluated. RESULTS: In the in vitro study, the mean capture rate was 94% and 35% in the IFD and Spider groups, respectively. In the in vivo study, all procedures were successful, with no complications. The mean delivery time was 281 ± 87 s and 194 ± 67 s and the mean retrieval time was 24 ± 9 and 13 ±1 s in the left internal carotid and the left common iliac arteries, respectively. CONCLUSION: Although further studies and improvements are required, the study results indicate that the IFD is feasible.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Arteria Carótida Interna , Cateterismo Periférico/instrumentación , Dispositivos de Protección Embólica , Arteria Ilíaca , Dispositivos de Acceso Vascular , Angiografía , Animales , Cateterismo Cardíaco/efectos adversos , Arteria Carótida Interna/diagnóstico por imagen , Cateterismo Periférico/efectos adversos , Remoción de Dispositivos , Arteria Ilíaca/diagnóstico por imagen , Ensayo de Materiales , Modelos Anatómicos , Modelos Animales , Modelos Cardiovasculares , Diseño de Prótesis , Sus scrofa , Factores de Tiempo
11.
Circ J ; 82(2): 376-387, 2018 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-28978818

RESUMEN

BACKGROUND: The comparative efficacy of second-generation (G2) vs. first-generation (G1) drug-eluting stents (DES) for calcified coronary lesions is unknown.Methods and Results:We compared the 3-year clinical outcomes of patients with G1- or G2-DES according to the presence or absence of calcified coronary lesions as assessed in an angiographic core laboratory using data from 2 large-scale prospective multicenter randomized trials, RESET and NEXT. G1-DES and G2-DES were implanted in 299 and 1,033 patients, respectively, in the Calc stratum (≥1 lesion with moderate/severe calcification), and 1,208 and 3,550 patients, respectively, in the Non-calc stratum (no/mild calcification). The patients in the Calc stratum had a significantly higher adjusted risk for the primary outcome measure (any target-lesion revascularization (TLR)) than those in the Non-calc stratum (HR: 1.38, 95% CI: 1.11-1.71, P=0.004). The cumulative 3-year incidence of any TLR was not significantly different between the G1-DES and G2-DES groups in both the Calc and Non-calc strata (12.1% vs. 9.7%, P=0.22, and 6.8% vs. 6.1%, P=0.44, respectively). After adjusting for confounders, the effect of G2DES relative to G1-DES for any TLR remained insignificant in both the Calc and Non-calc strata (HR: 0.78, 95% CI: 0.48-1.25, P=0.3, and HR: 0.84, 95% CI: 0.61-1.17, P=0.31, respectively, P interaction=0.55). CONCLUSIONS: The effect of G2-DES relative to G1-DES for TLR was not significantly different regardless of the presence or absence of lesion calcification.


Asunto(s)
Calcinosis/terapia , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos/normas , Anciano , Everolimus/administración & dosificación , Femenino , Humanos , Inmunosupresores , Masculino , Persona de Mediana Edad , Revascularización Miocárdica/normas , Sirolimus/administración & dosificación , Sirolimus/análogos & derivados , Resultado del Tratamiento
13.
Circulation ; 133(19): 1878-91, 2016 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-27009629

RESUMEN

BACKGROUND: Age and sex are important considerations in the choice between percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG) in daily clinical practice. METHODS AND RESULTS: Of 25 816 patients enrolled in the multicenter Coronary Revascularization Demonstrating Outcome Study in Kyoto (CREDO-Kyoto; Cohort-1, n=9877; Cohort-2, n=15 939), the present study population consisted of 5651 patients (men, n=3998; women, n=1653) with triple-vessel coronary artery disease who were considered to be pertinent in comparisons of PCI with CABG (PCI, n=3165; CABG, n=2486). Patients were divided into 3 groups according to the tertiles of age: ≤65 years (n=1972), 66 to 73 years (n=1820), and ≥74 years (n=1859). The excess adjusted mortality risk of PCI relative to CABG was significant in patients ≥74 years of age (hazard ratio [HR], 1.40; 95% confidence interval [CI], 1.10-1.79; P=0.006), whereas the risks were neutral in patients ≤65 years of age (HR, 1.05; 95% CI, 0.73-1.53; P=0.78) and in patients 66 to 73 years of age (HR, 1.03; 95% CI, 0.78-1.36; P=0.85; interaction P=0.003). The excess mortality risk of PCI relative to CABG was significant in men (HR, 1.24; 95% CI, 1.03-1.50; P=0.02) and trended to be significant in women (HR, 1.34; 95% CI, 0.98-1.84; P=0.07) without significant interaction between sex and the mortality risk of PCI relative to CABG (interaction P=0.40). CONCLUSIONS: There was a significant association between age and the mortality risk of PCI relative to CABG with excess risk in patients ≥74 years of age and neutral risk in younger patients. There was no significant sex-related difference in the mortality risk of PCI relative to CABG.


Asunto(s)
Envejecimiento , Puente de Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea/mortalidad , Caracteres Sexuales , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Puente de Arteria Coronaria/tendencias , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/tendencias , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento
14.
Circ J ; 81(8): 1129-1136, 2017 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-28381693

RESUMEN

BACKGROUND: In ST-segment elevation myocardial infarction (STEMI), QRS score at presentation ECG may reflect the progression of infarction and facilitate prediction of the degree of myocardial salvage achieved by reperfusion therapy.Methods and Results:Admission electrocardiogram (ECG) was studied in 2,607 patients with STEMI undergoing primary percutaneous coronary intervention (PCI) within 24 h of symptom onset. Patients were classified into 3 groups according to QRS score: low (0-3, n=1,227), intermediate (4-7, n=810), and high (≥8, n=570). An increase of infarct size estimated by median peak creatine phosphokinase was observed as QRS score increased (low score, 1,836 IU/L; inter-quartile range (IQR), 979-3,190 IU/L; intermediate score, 2,488 IU/L; IQR, 1,126-4,640 IU/L; high score, 3,454 IU/L; IQR, 1,759-5,639 IU/L; P<0.001). Higher QRS score was associated with higher long-term mortality (low, intermediate, and high score, 15.6%, 19.7%, and 23.7% at 5 years, respectively; log-rank P<0.001). The positive relationship of QRS score with mortality was consistently seen when stratified by infarct location. The association of high QRS score with increased mortality was most remarkably seen in patients with early (≤2 h) presentation (low, intermediate, and high score: 16.7%, 16.6%, and 28.1% at 5 years, respectively; log-rank P<0.001). CONCLUSIONS: Higher QRS score at presentation ECG was associated with larger infarct size, and higher long-term mortality in patients with STEMI undergoing primary PCI. QRS score appears to be important in the early risk stratification for STEMI.


Asunto(s)
Electrocardiografía , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio con Elevación del ST/sangre , Infarto del Miocardio con Elevación del ST/mortalidad , Infarto del Miocardio con Elevación del ST/fisiopatología , Infarto del Miocardio con Elevación del ST/cirugía
15.
Circ J ; 80(2): 526-34, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26742587

RESUMEN

BACKGROUND: ST-segment elevation (STE) in leads V1-2 is often observed in patients with severe aortic stenosis (AS), but its significance remains unknown. METHODS AND RESULTS: We retrospectively evaluated baseline ECGs and 5-year clinical outcomes in 211 consecutive patients with severe AS, defined as peak aortic jet velocity (Aortic Vmax) >4.0 m/s, or mean aortic pressure gradient >40 mmHg, or aortic valve area (AVA) <1.0 cm(2). The primary outcome measure was a composite of death or surgical aortic valve replacement (AVR). Patients with STE in leads V1-2(≥0.15 mV) had greater Aortic Vmax and smaller AVA than patients without. With a median follow-up of 4.9 years, the cumulative 5-year incidence of death or AVR was significantly higher in patients with STE in leads V1-2 than in patients without (91.4% vs. 77.1%; P=0.003). After adjusting for confounders, STE in leads V1-2 was independently associated with higher risk for death or AVR (hazard ratio, 1.53; 95% confidence interval, 1.06-2.22; P=0.02). In 64 asymptomatic patients without any indication for AVR at initial diagnosis of severe AS, the cumulative incidence of AVR was significantly higher in patients with STE in leads V1-2 than in patients without (57.6% vs. 30.5%; P<0.001). CONCLUSIONS: STE in leads V1-2 independently predicted poorer prognosis and more frequent need for AVR in patients with severe AS.


Asunto(s)
Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Presión Sanguínea , Electrocardiografía , Anciano , Anciano de 80 o más Años , Bases de Datos Factuales , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
16.
Circ J ; 80(2): 477-84, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26667590

RESUMEN

BACKGROUND: In the setting of elective percutaneous coronary intervention (PCI), intravascular ultrasound (IVUS)-guided PCI is associated with a reduction in the incidence of target vessel revascularization (TVR), but the impact of IVUS on long-term clinical outcome in the setting of emergency PCI for ST-segment elevation acute myocardial infarction (STEMI) is still unclear. METHODS AND RESULTS: The subjects consisted of 3,028 STEMI patients who underwent primary PCI within 24 h of symptom onset in the CREDO-Kyoto acute myocardial infarction registry. Of these, 932 patients (31%) underwent IVUS-guided PCI. Compared with the angiography-guided PCI without IVUS, IVUS-guided PCI was associated with significantly lower incidences of TVR (primary outcome measure; 22% vs. 27%, log-rank P<0.001) and definite stent thrombosis (ST; 1.2% vs. 3.1%, log-rank P=0.003). The cumulative incidence of all-cause death was not significantly different between the 2 groups. After adjusting for confounders, however, there were no significant differences between the 2 groups in risk for TVR (adjusted HR, 1.14; 95% CI: 0.86-1.51, P=0.38) and definite ST (adjusted HR, 0.58; 95% CI: 0.19-1.72, P=0.33). CONCLUSIONS: IVUS-guided PCI was not associated with a lower risk for TVR or ST in STEMI patients undergoing primary PCI.


Asunto(s)
Angiografía Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Sistema de Registros , Ultrasonografía Intervencional , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Japón/epidemiología , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/mortalidad , Infarto del Miocardio/cirugía
17.
Circ J ; 80(8): 1764-72, 2016 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-27350014

RESUMEN

BACKGROUND: Inter-facility transfer for primary percutaneous coronary intervention (PCI) from referring facilities to PCI centers causes a significant delay in treatment of ST-segment elevation acute myocardial infarction (STEMI) patients undergoing primary PCI. However, little is known about the clinical outcomes of STEMI patients undergoing inter-facility transfer in Japan. METHODS AND RESULTS: In the CREDO-Kyoto acute myocardial infarction (AMI) registry that enrolled 5,429 consecutive AMI patients in 26 centers in Japan, the current study population consisted of 3,820 STEMI patients who underwent primary PCI within 24 h of symptom onset. We compared long-term clinical outcomes between inter-facility transfer patients and those directly admitted to PCI centers. The primary outcome measure was a composite of all-cause death or heart failure (HF) hospitalization. There were 1,725 (45.2%) inter-facility transfer patients, and 2,095 patients (54.8%) with direct admission to PCI centers. The cumulative 5-year incidence of death/HF hospitalization was significantly higher in the inter-facility transfer patients than in those with direct admission (26.9% vs. 22.2%; log-rank P<0.001). After adjusting for potential confounders, the risk for death/HF hospitalization was significantly higher (adjusted hazard ratio: 1.22, 95% confidence interval: 1.07-1.40, P<0.001) in the inter-facility transfer patients than in those directly admitted. CONCLUSIONS: Inter-facility transfer was associated with significantly worse long-term clinical outcomes for patients with STEMI undergoing primary PCI. (Circ J 2016; 80: 1764-1772).


Asunto(s)
Admisión del Paciente , Transferencia de Pacientes , Intervención Coronaria Percutánea , Sistema de Registros , Infarto del Miocardio con Elevación del ST/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Japón/epidemiología , Masculino , Persona de Mediana Edad , Infarto del Miocardio con Elevación del ST/mortalidad
18.
Heart Vessels ; 30(6): 830-4, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25028168

RESUMEN

Balloon aortic valvuloplasty (BAV) has played a limited role in the management of patients with severe aortic stenosis. However, BAV is being performed more frequently these days with the emergence of transcatheter aortic valve implantation (TAVI). We previously described a technique named "looped Inoue balloon technique" to simplify the antegrade transvenous BAV by making a loop in the left atrium using two stylets. We present a case in which the looped Inoue balloon technique was successfully applied. The patient was an 83-year-old woman with progressive dyspnea due to severe aortic stenosis. The aortic valve area was 0.39 cm(2) with a mean transvalvular gradient of 46 mmHg. The patient was deemed high risk for surgical aortic valve replacement or TAVI in view of the multiple comorbidities and frailty. Antegrade BAV using the looped Inoue balloon technique was performed. The procedure was successful without any complications. The post procedural aortic valve area increased to 1.15 cm(2) with a mean pressure gradient of 23 mmHg. This is the first report of clinical use of the looped Inoue balloon technique for antegrade BAV.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Valvuloplastia con Balón/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano de 80 o más Años , Cateterismo Cardíaco , Ecocardiografía , Femenino , Atrios Cardíacos/cirugía , Humanos
19.
PLoS One ; 19(1): e0297263, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38271400

RESUMEN

OBJECTIVE: The frozen lesion formation created by cryoballoon ablation, especially with non-occluded applications, has not been fully evaluated. This study aimed to validate the lesion size under different cryoballoon ablation settings: application duration, push-up technique, and laminar flow. METHODS: The frozen lesion size was evaluated immediately after ending the freezing with three different application durations (120, 150, and 180 seconds) in porcine hearts (N = 24). During the application, the push-up technique was applied at 10, 20, and 30 seconds after starting the freezing with or without laminar flow. RESULTS: The lesion size was significantly correlated with the nadir balloon temperature (P<0.001). The lesion volume became significantly larger after 150 seconds than 120 seconds (1272mm3 versus 1709mm3, P = 0.004), but not after 150 seconds (versus 1876mm3 at 180 seconds, P = 0.29) with a comparable nadir balloon temperature. Furthermore, the lesion volume became significantly larger with the push-up technique with the largest lesion size with a 20-second push-up after the freezing (1193mm3 without the push-up technique versus 1585mm3 with a push-up at 10 seconds versus 1808mm3 with a push-up at 20 seconds versus 1714mm3 with a push-up at 30 seconds, P = 0.04). Further, the absence of laminar flow was not associated with larger lesion size despite a significantly lower nadir balloon temperature. CONCLUSION: The frozen lesion size created by cryoballoon ablation became larger with longer applications at least 150 seconds and with a push-up technique especially at 20 seconds after the freezing.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Animales , Porcinos , Congelación , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Criocirugía/métodos , Temperatura , Fibrilación Atrial/cirugía , Resultado del Tratamiento
20.
J Cardiol ; 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38521118

RESUMEN

BACKGROUND: Data on the incidence, timing, and severity of myocardial damage after anthracycline-based chemotherapy (AC) in Japanese patients with breast cancer are limited. METHOD: We evaluated cancer therapy-related cardiac dysfunction (CTRCD) in Japanese women with breast cancer (n = 51) after the first AC according to the definitions of the 2022 European Society of Cardiology onco-cardiology guideline, including assessment of high-sensitivity troponin I (TnI) and B-type natriuretic peptide (BNP) levels. RESULTS: CTRCD was detected in 67 % of the patients (3.9 %, 7.8 %, 9.8 %, 43 %, 37 %, 22 %, 20 %, and 9.8 % of patients at 1 week and 1, 2, 3, 6, 9, 12, and 15 months post-AC, respectively) without significant left ventricular ejection fraction reduction (<50 %) and heart failure. Elevated TnI levels (>26 pg/mL) were found in 43 % of patients, and elevated BNP levels (≥35 pg/mL) were observed in 22 % of patients during the follow-up period. CONCLUSIONS: Approximately two-thirds of the Japanese patients in this study experienced CTRCD, which was frequently observed at 3 or 6 months post-AC. However, all patients with CTRCD were diagnosed with mild asymptomatic CTRCD. Although, these patients were diagnosed with mild asymptomatic CTRCD, careful long-term follow-up will be required.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA