Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Arthroplasty ; 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38848790

RESUMEN

BACKGROUND: Periprosthetic joint infection (PJI) continues to be one of the leading causes of failure following total hip arthroplasty (THA). The objectives of the study were to (1) determine the minimum 2-year infection-free survivorship of 2-stage revision THA, (2) determine the causative organisms for repeat 2-stage revision THA, and (3) characterize the results of failed 2-stage revisions and evaluate patient-reported outcome measures (PROMs). METHODS: A retrospective chart review was completed for patients who underwent 2-stage revision THA for PJI. Prospective data were collected on each patient, including demographics, causative organisms, complications, and type of reoperation. The PROMs, including Harris Hip Score, 12-item Short-Form Health Survey, and Western Ontario and McMaster Universities Osteoarthritis Index scores were obtained prior to 2-stage revision THA surgery and annually as part of standard clinical and radiographic follow-up. RESULTS: A total of 328 patients who underwent a 2-stage revision THA for a PJI were included in the study (mean age 67 years [range, 28 to 90], mean body mass index of 30.6 [range, 15 to 57]). The overall infection-free survivorship for 2-stage revision THA was 73.8% at a minimum of 2 years (range, 2 to 20). Overall, 194 (59.1%) patients who had successful infection eradication underwent a 2-revision THA only. The most common single organisms infected were Staphylococcus aureus (12.5%) and Staphylococcus epidermidis (11%). Higher reoperation rates were found in cases with methicillin-resistant Staphylococcus aureus and polymicrobial infections. All PROMs showed statistical improvement from preoperatively to the latest follow-up appointment. CONCLUSIONS: Two-stage revision THA is associated with a good success rate in the treatment of PJIs at mid-term to long-term follow-up. Polymicrobial and methicillin-resistant Staphylococcus aureus infections are poor prognostic factors, making the eradication of infection more difficult. The management of PJIs continues to be one of the most important orthopaedic challenges to treat.

2.
J Arthroplasty ; 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38522799

RESUMEN

BACKGROUND: Bicruciate-stabilized (BCS) total knee arthroplasty (TKA) designs attempt to approximate natural knee mechanics. Multiple surgical techniques, including gap balancing (GB) and measured resection (MR), have been developed to provide optimal implant positioning and soft-tissue balance. The goal of this study was to determine the effect of surgical technique on BCS TKA contact kinematics. Secondary goals included investigating the change of kinematics over time and comparing BCS TKA kinematics to a posterior-stabilized (PS) design. METHODS: The study included the BCS-GB, BCS-MR, and PS-MR groups. The BCS-GB and BCS-MR groups underwent weight-bearing radiostereometric analysis for multiple knee flexion angles at 3 months and 1 year postoperatively, whereas the PS-MR group was imaged at 1 year postoperatively. The medial and lateral contact kinematics were determined from implant poses. RESULTS: There were no differences in BCS TKA kinematics between the GB and MR techniques. There were differences in the mid-flexion ranges when comparing the 3-month and 1-year kinematics of the BCS design; however, they were less than 1.5 mm. Differences existed between the kinematics of the BCS and PS designs at all flexion angles for the medial condyle (P < .0006) and at 0° of flexion on the lateral condyle (P < .0001). CONCLUSIONS: Contact kinematics for a BCS design were similar for both surgical techniques, suggesting both are appropriate for this design. Small, likely clinically insignificant differences were found between 3-month and 1-year kinematics. The BCS TKA kinematics differed from the PS design; however, it is unclear whether these differences improve clinical outcomes.

3.
J Arthroplasty ; 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38710347

RESUMEN

BACKGROUND: Routine patellar resurfacing during primary total knee arthroplasty (TKA) remains controversial. To our knowledge, there are no studies reporting the long-term performance of a cemented biconvex all-polyethylene inlay component implanted at the time of primary TKA. The purpose of this study was to examine the 15-year survivorship and long-term clinical outcomes of this biconvex inlay patella used at our institution. METHODS: We retrospectively reviewed our prospectively collected institutional database and identified 2,530 patients who underwent cemented TKA with a single prosthetic design (from 1996 to 2007) where the patella was resurfaced using this cemented biconvex inlay patella. The mean age at surgery was 68 years (range, 29 to 93). The mean body mass index was 33.0 (range, 16.4 to 76.3), with 61.9% women. At the time of analysis, the mean time from surgery was 20.4 years (range, 15 to 26). We used Kaplan-Meier analysis to calculate survivorship at 15 years. We analyzed clinical outcomes using 3 patient-reported outcome measures collected prospectively. RESULTS: The 15-year survivorship with revision surgery for all causes as the end point was 97.1% (95% confidence interval 96.1 to 98.1%). The 15-year survivorship with revision surgery for a patella-related complication as the end point was 99.7% (95% confidence interval 99.4 to 1.0). At the final follow-up, patients showed significant improvement in scores for the Knee Society Clinical Rating System (P < .001), Western Ontario and McMaster University Osteoarthritis Index (P < .001), and Veterans Rand 12-Item Health Survey physical component (P < .001). CONCLUSIONS: Routine patellar resurfacing using a biconvex inlay patellar component has excellent survivorship and a low rate of complications at 15 years post-TKA.

4.
J Arthroplasty ; 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38521249

RESUMEN

BACKGROUND: Modular titanium fluted tapered (TFT) stems have demonstrated excellent clinical success for femoral revision total hip arthroplasty (THA) surgery. This study reports the short-term outcomes of a novel modern monoblock TFT stem used for revision and complex primary THA with a minimum of 2 years of follow-up. METHODS: We identified 126 patients who received a single monoblock TFT stem: 26 patients for complex THA (failed fracture fixation) and 100 patients for revision THA. The reasons for revision THA included 40 for previous periprosthetic joint infection, 42 for aseptic loosening, 9 for trunnionosis, and 9 for periprosthetic fractures. The Paprosky grading for femoral bone loss at the time of surgery and the measured subsidence of femoral stems at 3-month follow-up were determined. We evaluated the number and indications for reoperations. RESULTS: The mean time from surgery was 3.9 years (range, 2.0 to 6.9). A paired t-test analysis showed significant improvement from preoperative versus postoperative clinical outcome scores (P < .001) for Harris Hip Score (38.76 ± 15.24 versus 83.42 ± 15.38), Western Ontario and McMaster Universities Arthritis Index (45.6 ± 19.0 versus 69.9 ± 21.3), Veterans RAND 12 Item Health Survey Physical component (31.7 ± 8.1 versus 37.8 ± 11.3), and Veterans RAND 12 Item Health Survey Mental component (48.2 ± 12.2 versus 51.6 ± 12.5). The Paprosky grading for femoral bone loss was Grade 1 (3.9%), Grade 2 (35.7%), Grade 3A (47.6%), Grade 3B (11.1%), and Grade 4 (1.6%) cases. There were 18 reoperations (14.7%), with 13 for periprosthetic joint infection (7 treated with implant retention and 6 treated with a 2-stage revision), 4 for instability, and 1 for acetabular aseptic loosening. There were no aseptic failures of the stem. CONCLUSIONS: This novel modern monoblock TFT stem provided reliable femoral fixation and has increasingly supplanted the use of modular TFT stems for complex primary and revision surgery in our institution.

5.
J Arthroplasty ; 39(3): 689-694.e3, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37739141

RESUMEN

BACKGROUND: The objective of this study was to identify the rate and risk factors for revision total knee arthroplasty (TKA) within the first 5 years postoperative. Our secondary objective was to identify the rate of additional surgical procedures and death. METHODS: We conducted a retrospective cohort study among patients in Ontario, Canada who underwent an elective, primary TKA between April 1, 2007, and March 31, 2014, for osteoarthritis. We excluded patients under 40 years and who had undergone a TKA within the previous 15 years. Our final study cohort included 94,193 patients. We reported the proportion of the study cohort who experienced revision surgery within 2 and 5 years of the primary TKA; secondary surgery within 5 years. We conducted Cochran-Armitage tests for trends to assess changes in the proportion of patients who experienced each of the study outcomes, and multivariable logistic regressions to evaluate predictors of a revision TKA. RESULTS: There were 3,112 (3.3%) patients who had a revision within 5 years, and 1,866 (2.0%) within 2 years of their primary TKA. 3,316 (3.5%) had a secondary surgery (0.6% patellar resurfacing; 1.6% manipulation; 1.3% synovectomy; 0.5% washout; 0.9% debridement). Lower age, men, lower income, higher comorbidity score, depression, previous arthroscopy, lower surgeon volume, and general anesthesia were all significant positive predictors of revision. CONCLUSIONS: In our study cohort, 2.0% of patients had a revision TKA within 2 years, and 3.3% within 5 years of their primary TKA. Preoperative identification of risk factors may reduce the future prevalence of revision TKAs.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Masculino , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/etiología , Ontario/epidemiología , Reoperación/métodos , Articulación de la Rodilla/cirugía
6.
J Arthroplasty ; 38(6S): S355-S362, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36758840

RESUMEN

BACKGROUND: Contact kinematics in total knee arthroplasty (TKA) has been shown to affect tibial component migration. However, previous studies correlating kinematic variables to implant migration were completed with older TKA designs. The goal of this study was to determine if there are associations between contact kinematics and tibial component migration for a cemented, bicruciate stabilized (BCS) TKA system. METHODS: A total of 54 knees implanted with a BCS TKA system were analyzed using radiostereometric analysis (RSA). Patients underwent RSA exams at 2 weeks, 6 weeks, 3 months, 6 months, 1 year, and 2 years post operation to measure tibial component migration. At 1 year, contact kinematics was evaluated during a quasi-static deep knee bend. Linear regression analyses were performed between kinematic variables and migration values. RESULTS: Significant correlations were found between contact kinematics and tibial component migration. Excursion on the lateral condyle was the most consistent variable correlating with implant migration. Six patients had > 0.2 mm migrations from 1 to 2 years post operation indicating continuously migrating tibial components, and most had atypical contact kinematics. CONCLUSION: Kinematics was shown to influence tibial component migration. Reduced lateral excursion, suggesting a more constrained lateral condyle, resulted in greater implant migration. The 6 patients who had continuously migrating tibial components had demographic factors that may limit the ability to endure unintended force transmissions caused by abnormal kinematics. These results highlight the importance of restoring knee kinematics with this BCS TKA design to minimize improper force transmissions and resultant increased implant migrations.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Fenómenos Biomecánicos , Articulación de la Rodilla/cirugía , Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Rango del Movimiento Articular
7.
J Arthroplasty ; 38(7S): S223-S228, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36963526

RESUMEN

BACKGROUND: Subsidence remains a concern when utilizing tapered fluted titanium (TFT) femoral stems and may lead to leg length discrepancy, impingement, instability, and failure to obtain osseointegration. This study aims to compare stem subsidence across 3 modern TFT stems. Our secondary aim was to investigate the influence of bicortical contact or "scratch fit" on subsidence, as well as the role of intraoperative imaging in maximizing bicortical contact and preventing stem subsidence. METHODS: A retrospective review of 271 hip arthroplasties utilizing modern TFT stems at a single institution was performed. Three stem designs were included in the analysis: 1 monoblock TFT stem (n = 91) and 2 modular TFT stems (n = 90; n = 90). Patient demographics, Paprosky femoral bone loss classification, bicortical contact, utilization of intraoperative imaging, and stem subsidence (comparison of initial postoperative radiograph to the latest follow-up radiograph-minimum 3 months) were recorded. RESULTS: There was no statistically significant difference in overall subsidence (P = .191) or the incidence of subsidence >5 millimeters between stems (P = .126). Subgroup analysis based on femoral bone loss grading showed no difference in subsidence between stems. Increased bicortical contact was associated with reduced subsidence (P = .004). Intraoperative imaging was used in 46.5% (126 of 271) of cases; this was not correlated with bicortical contact (P = .673) or subsidence (P = .521). CONCLUSION: All 3 modern TFT stems were highly successful and associated with low rates of subsidence, regardless of modular or monoblock design. Surgeons should select the stem that they feel is most clinically appropriate.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Titanio , Diseño de Prótesis , Reoperación , Fémur/diagnóstico por imagen , Fémur/cirugía , Estudios Retrospectivos
8.
J Arthroplasty ; 38(6S): S297-S301, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37003457

RESUMEN

BACKGROUND: Hybrid fixation, utilizing diaphyseal press-fit stems and cement fixation in the tibial and femoral metaphyseal areas, has long been a strategy for revision total knee arthroplasty (rTKA). The purpose of this study was to evaluate the clinical outcomes and survivorships of hybrid fixation using a single rTKA revision system with a minimum of 5 years follow-up. METHODS: We reviewed our prospectively collected database to identify 281 patients who underwent rTKA using a single revision system with hybrid fixation and press-fit stems between July 2006 and August 2016. We reviewed the clinical outcome scores, including the Knee Society Score, Western Ontario and McMaster Universities Osteoarthritis index, and Veterans RAND 12 Item Health Survey. We also evaluated the 5 and 10-year survivorships and the indications for reoperations. The cohort had a mean age of 70 years (range, 45.2 to 92.0) and a mean body mass index of 33.4 (range, 17.3 to 55.8). The mean time from rTKA surgery was 11.1 years (range, 5.3 to 15.5). RESULTS: Paired t-test analyses showed significant improvements from preoperative versus postoperative clinical outcome scores (P < .001) for Knee Society Score, Western Ontario and McMaster Universities Osteoarthritis, and Veterans RAND 12 Item Health Survey Physical component. Prosthetic joint infections after index rTKA were the most common failure mode with 29 patients requiring reoperations. Rerevision due to aseptic loosening was uncommon (6 patients) with a cumulative survival rate of 95.2% at 5 years and 94.2% at 10 years. CONCLUSION: The use of this single rTKA system utilizing press fit stems combined with hybrid fixation provided significant improvements in the clinical outcomes and excellent survivorships at 5 and 10 years.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis , Humanos , Anciano , Articulación de la Rodilla/cirugía , Supervivencia , Diseño de Prótesis , Reoperación , Osteoartritis/cirugía , Estudios Retrospectivos , Falla de Prótesis , Resultado del Tratamiento
9.
J Arthroplasty ; 37(7S): S413-S415.e1, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35277309

RESUMEN

BACKGROUND: In March 2020, an emergency was declared in the province of Ontario owing to the COVID-19 pandemic. From March 19 to May 26, all elective total hip arthroplasty (THA) and total knee arthroplasty (TKA) procedures were deferred. The purpose of this study was to review the unit sales data of THA and TKA procedures in Ontario over this time period to identify any trends in surgical activity. METHODS: Unit sales data for all THA and TKA procedures performed in Ontario between January 2019 and December 2020 were reviewed. All orthopedic companies contributed to the data set. Femoral stems were considered an indicator of THA procedures, while primary femurs were considered an indicator of TKA procedures. Data were analyzed to determine trends in THA and TKA procedures during the deferral period and the relative change in THA and TKA activity following resumption. RESULTS: There was a 53% reduction in THA activity between March and May of 2020 when compared to the same interval in 2019. From June to September of 2019, THA sales activity was 87.3% that of TKA. From June to September of 2020, THA sales activity was 122.8% that of TKA. CONCLUSION: Provincial directives aimed at controlling the outbreak of COVID-19 contributed to a substantial reduction in THA and TKA activity in 2020. Compared to 2019, there was a disproportionate increase in THA compared to TKA activity in 2020 following resumption of surgical services. These data have implications in recovery planning for the surgical backlog of THA in Ontario.


Asunto(s)
Artroplastia de Reemplazo de Cadera , COVID-19 , COVID-19/epidemiología , Humanos , Ontario/epidemiología , Pandemias , Estudios Retrospectivos
10.
J Arthroplasty ; 37(7S): S692-S696, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35245689

RESUMEN

BACKGROUND: Oxidized zirconium (OxZi) femoral heads combine the decreased abrasive properties of ceramics with the toughness of metal alloys to lower wear and increase the durability of total hip arthroplasty. The purpose of this study was to compare the 10-year polyethylene wear rates between OxZi/XLPE and cobalt chrome (CoCr)/XLPE articulations. METHODS: A radiostereometric analysis (RSA) was performed on two cohorts of 23 patients who underwent total hip arthroplasty using either OxZi/XLPE or CoCr/XLPE at a minimum of 10-year follow-up. Cohorts were matched for age, gender, body mass index (BMI), and diagnosis. Polyethylene wear was measured using RSA to determine total and steady-state wear rates for both cohorts. Preoperative and postoperative patient-reported outcome measures (SF12, HHS, and Western Ontario and McMaster Universities Arthritis Index scores) were compared. RESULTS: The mean total head penetration rate was found to be statistically different between the entire cohorts (OxZi 0.048 ± 0.021 mm/y, CoCr 0.035 ± 0.017 mm/y, P = .02) but not when 28-mm heads only (OxZi 0.045 ± 0.016 mm/y, CoCr 0.034 ± 0.017 mm/y, P = .066) were directly compared. The mean steady-state wear rate was not significantly different between the entire cohorts (OxZi 0.031 ± 0.021 mm/y, CoCr 0.024 ± 0.019 mm/y, P = .24) or 28-mm head cohorts (OxZi 0.028 ± 0.019 mm/y, CoCr 0.024 ± 0.019 mm/y, P = .574). Outcome measures showed no statistical difference except for the Harris Hip Score where the OxZi cohort demonstrated higher median scores. CONCLUSION: Using RSA to evaluate the 10-year in-vivo head penetration, there was no statistically significant difference in steady-state wear rates between OxZi and CoCr articulations. Both bearing combinations demonstrated wear rates well below the threshold for osteolysis.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Aleaciones de Cromo , Cobalto , Estudios de Seguimiento , Prótesis de Cadera/efectos adversos , Humanos , Polietileno , Diseño de Prótesis , Falla de Prótesis , Análisis Radioestereométrico , Circonio
11.
J Arthroplasty ; 37(6S): S98-S104, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35569919

RESUMEN

BACKGROUND: Implant migration and altered kinematics have been thought to impact patient-reported outcome measures (PROMs) and postoperative patient satisfaction. In this study comparing satisfied and dissatisfied total knee arthroplasty (TKA) patients, we hypothesized that dissatisfied patients will have greater continuous implant migration and that there will be differences in joint kinematics, objective functional measurements, and PROMs between satisfied and dissatisfied patients. METHODS: The Knee Society Score Satisfaction Subsection questions regarding satisfaction with function were used at least 6 months postoperation to split 50 patients into satisfied and dissatisfied groups. Patients underwent radiostereometric analysis to evaluate migration and kinematics. A wearable sensor system obtained objective measurements of patient function during timed up and go tests. PROMs were recorded preoperation and postoperation. RESULTS: No statistically significant differences were found in migration between satisfied and dissatisfied groups. Statistical kinematic differences existed in lateral anteroposterior contact location at 20° and 40° of flexion at 1 year, where the dissatisfied group had more anteriorly located lateral contact. No statistically significant differences were present in objective functional measurements. Satisfied and dissatisfied groups had differing PROMs at 4 timepoints or greater for each questionnaire. CONCLUSIONS: No differences were found in tibial component migration or objectively measured function between satisfied and dissatisfied patients. Functionally dissatisfied patients had more anteriorly positioned contact on the lateral condyle in early flexion and reported more pain and unmet expectations. These findings suggest that improving the functional satisfaction of TKA requires restoration of kinematics in early flexion and management of patient's pain and expectations.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Fenómenos Biomecánicos , Humanos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Dolor/cirugía , Satisfacción del Paciente , Satisfacción Personal , Rango del Movimiento Articular
12.
J Arthroplasty ; 37(11): 2262-2271, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35598759

RESUMEN

BACKGROUND: The prevalence and outcomes of unexpected positive intraoperative cultures (UPC) in presumed aseptic revision total knee arthroplasty (TKA) are unclear. The purpose of this study was to determine the prevalence of UPC and infection-free implant survival in this patient population. Secondly, we aimed to compare the infection-free implant survival between cohorts based on number of UPCs and antibiotic treatment. METHODS: We reviewed our institutional database from 2006 to 2019 for all TKA revisions (n = 1795) to identify all presumed aseptic TKA revisions with intraoperative culture(s). After exclusions, 775 revisions were eligible and those with UPC were included in the Kaplan-Meier analysis to determine infection-free implant survival for the cohorts. RESULTS: The prevalence of UPC was 9.8%. The 2- and 5-year infection-free survival was 97.4% and 95.3%, respectively. The 5-year infection-free survival from the same microorganism as the UPC was 98.7%. Infection-free survival was similar for the 1 versus ≥2 UPC cohorts (P = .416), however was poorer for the cohort treated with antibiotics (P = .021). Only one of 3 subsequent PJI-related implant failures was caused by the same microorganism (polymicrobial) as the UPC. There were no subsequent infections in patients with a single UPC not treated with antibiotics. CONCLUSIONS: The prevalence of UPC was 9.8% and the infection-free implant survival is excellent. Infection-free survivorship from PJI caused by the same UPC microorganism is outstanding. Comparisons between cohorts must be interpreted with caution due to study limitations. A single UPC in patents without other signs of infection does not require antibiotic treatment. LEVEL OF EVIDENCE: IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Infecciones Relacionadas con Prótesis , Antibacterianos/uso terapéutico , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Prótesis de la Rodilla/efectos adversos , Prevalencia , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Reoperación/efectos adversos , Estudios Retrospectivos
13.
J Arthroplasty ; 37(6S): S263-S269, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35257822

RESUMEN

BACKGROUND: Bone loss remains an anticipated challenge in revision total knee arthroplasty (rTKA). Recent efforts to enhance rTKA fixation and stability have focused on metaphyseal implants, namely cones and sleeves. We sought to compare cone and sleeve implant survivorship in rTKA. METHODS: One hundred eighty patients who underwent rTKA with metaphyseal implants from 2005 to 2018 were retrospectively reviewed. A total of 83 cones (22 femoral, 62 tibial) and 121 sleeves (58 femoral, 63 tibial) were identified. The mean age at the time of surgery was 72 years (range 43-97). Intraoperative Anderson Orthopaedic Research Institute bone loss classifications included the following: type 2A (25), type 2B (98), and type 3 (81). Mean follow-up was 41 months. RESULTS: Revision-free survival for cones was 91.3% vs 92.2% for sleeves (P = .29). Twelve knees (4 cones, 8 sleeves) underwent irrigation, debridement, and polyethylene exchange with metaphyseal implant retention for acute postoperative periprosthetic joint infection (PJI). Development of chronic PJI warranted removal of 7 cones (8.4%), 6 of which were initially placed as part of a 2-stage revision TKA. Eight sleeves (6.6%) were removed for PJI, with all initially placed during a second stage reimplantation. In the absence of infection, survival was 100% and 99.1% for cones and sleeves, respectively. One sleeve was revised for periprosthetic fracture. CONCLUSION: Metaphyseal cones and sleeves offer equally durable survivorship in revision TKA. PJI was the most common mode of implant failure in this series. Importantly, no cases of cone or sleeve aseptic loosening were observed.


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Adulto , Anciano , Anciano de 80 o más Años , Artritis Infecciosa/cirugía , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Articulación de la Rodilla/cirugía , Persona de Mediana Edad , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Reoperación , Estudios Retrospectivos , Supervivencia
14.
J Arthroplasty ; 37(2): 252-258, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34710566

RESUMEN

BACKGROUND: The goal of this study is to investigate the migration and inducible displacement of a bicruciate-stabilized (BCS) total knee arthroplasty implanted using gap balancing (GB) or measured resection (MR) surgical techniques. We hypothesized equal migration and displacement between the techniques. METHODS: The study is a single-blinded, prospective, randomized controlled trial, with allocation of 71 patients to either GB or MR groups. Fifteen patients were withdrawn, resulting in 31 patients in the GB group and 25 in the MR group. Patients received the JOURNEY II™ BCS implant. Migration and inducible displacement were evaluated using radiostereometric analysis and patient examinations were performed at a 2-week baseline, and at 6 weeks, 3 months, 6 months, 1 year, and 2 years postoperation. RESULTS: No differences (P > .05) existed between GB and MR groups for any measurement of tibial or femoral migration. Both groups had tibial migrations below 0.5 mm from baseline to 6 months, and below 0.2 mm from both 6 months to 1 year and 1-2 years postoperation. No differences (P > .05) were found between GB and MR groups for inducible displacement. CONCLUSION: No differences were found in implant migration or inducible displacement between GB and MR groups. The BCS implant can be expected to have migration risks on par with industry standards and both surgical techniques are safe and effective options for implantation of this implant design.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Estudios Prospectivos , Análisis Radioestereométrico , Tibia/diagnóstico por imagen , Tibia/cirugía
15.
J Arthroplasty ; 35(6): 1662-1666, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32088053

RESUMEN

BACKGROUND: The rise in total hip arthroplasty (THA) has led to a concomitant increase in revision THAs. Tracking implant performance therefore remains a significant element of scientific inquiry to garner and maintain public trust in this procedure. There are few available reports of outcomes of a single manufacturer's total hip system outside registry data. METHODS: We performed a retrospective review of a prospectively generated database to evaluate outcomes of a single manufacturer's femoral stem and acetabular shell for THA. We report the functional outcomes, revision data, and survivorship for this total hip system. RESULTS: A total of 1942 primary THAs were implanted into 1672 patients. There were of 57 revisions. There were no cases of acetabular failure at 10-year follow-up. All functional outcome scores demonstrated significant improvements following THA. Kaplan-Meier survival analysis for all-cause revisions demonstrated 2-year implant survival of 97.6% (95% confidence interval [CI], 96.9-98.3), 5-year implant survival of 97.3% (95% CI, 96.5-98.1), and 10-year implant survival of 97.0% (95% CI, 96.0-98.0). When infection was excluded, implant survivorship improved to 99.2% (95% CI, 98.8-99.6) at 2 years, 98.9% (95% CI, 98.5-99.4) at 5 years, and 98.7% (95% CI, 98.1-99.4) at 10 years. CONCLUSION: This THA implant system comprising an uncemented press-fit acetabulum used alongside a triple-tapered femoral stem is an excellent option for THA. Implant survivorship at 2, 5, and 10 years is among the best reported for any total hip system in the world.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios de Seguimiento , Humanos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos , Supervivencia , Factores de Tiempo , Resultado del Tratamiento
16.
J Arthroplasty ; 35(5): 1323-1327, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31911095

RESUMEN

BACKGROUND: Rotating hinge knee prostheses (with or without distal femoral replacement) are indicated in cases of unreconstructible bony or soft tissue compromise. Despite their versatility, these implants have demonstrated high rates of mechanical failure. We aimed to review clinical outcomes of a novel hinged knee arthroplasty system. METHODS: We reviewed all cases in a prospective database of hinged total knee arthroplasty (with and without distal femoral arthroplasty) involving a single manufacturer's implant system at a large tertiary-level academic health sciences center. We collected reasons for surgery, implant survivorship, reasons for revision, and clinical outcomes (Short Form 12, Western Ontario and McMaster Universities Osteoarthritis Index, and Knee Society Scores). RESULTS: Seventy-six cases of hinged knee implants using the knee system under investigation were performed (39 hinged total knee and 37 distal femoral replacements) between 2011 and 2018, inclusive. Indications for surgery varied, with second-stage reimplantation most common for rotating hinge and fracture most common for distal femoral arthroplasty. There were 6 revisions in the rotating hinge group (none for aseptic loosening) and 5 in the distal femoral arthroplasty group (1 for aseptic loosening). Average follow-up was 2.89 ± 2.09 years. Postoperative Short Form 12 (Physical Component), Western Ontario and McMaster Universities Osteoarthritis Index, and Knee Society Scores were 30.12 ± 10.17, 55.90 ± 21.51, and 115.62 ± 45.20, respectively. CONCLUSION: This novel hinged knee system is a highly durable option for complex and revision knee arthroplasty. Early failures tend to be secondary to infection. We observed only a single case of aseptic loosening. Although these early results are encouraging, ongoing follow-up is required to determine long-term prognosis in patients receiving this implant.


Asunto(s)
Prótesis de la Rodilla , Humanos , Articulación de la Rodilla/cirugía , Diseño de Prótesis , Reoperación , Supervivencia
17.
Clin Orthop Relat Res ; 477(1): 80-90, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30794231

RESUMEN

BACKGROUND: Revision of TKA as a result of polyethylene wear is decreasing, but long-term wear performance of polyethylene is still a topic of interest to surgeons and device manufacturers seeking to improve longevity. Measuring wear of modern, wear-resistant implants has been described using radiostereometric analysis (RSA). Performing in vivo measurements would establish whether implant retrieval studies are representative of wear in well-performing knees. QUESTIONS/PURPOSES: For a single knee implant system, we sought to determine (1) the linear wear rate using RSA; (2) the association between demographic factors and wear rate; and (3) the association between limb alignment and wear rate. METHODS: A total of 49 patients with a minimum followup of 10 years (median, 12 years; range, 10-20 years) were retrospectively selected. During the examined period, 4082 TKAs were performed of which 2085 were the implant examined in this study. There were 71 of these patients who met the criteria including an available full-leg radiograph postoperatively, and 34 of these patients returned for examination along with 15 additional from a separate RSA study that also met the criteria. All patients received a posterior-stabilized, cobalt-chromium-on-conventional polyethylene total knee implant from a single implant system, which was the most commonly used at our institution at the time. Patients underwent standing RSA examinations from 0° to 120° of flexion at a single time point without the use of marker beads. Linear wear rates (including creep) were measured based on intersections between the femoral component and tibial insert models. Associations between wear and patient age at surgery, sex, height, weight, body mass index, tibial insert size, and limb alignment were examined. RESULTS: Using the maximum linear wear rate from any flexion angle, the lateral rate was 0.047 mm/year (interquartile range [IQR], 0.034-0.066 mm/year) and the medial rate was 0.052 mm/year (IQR, 0.040-0.069 mm/year). Using the median of the linear wear rates across all flexion angles, the lateral rate was 0.027 mm/year (IQR, 0.017-0.046 mm/year) and the medial rate was 0.038 mm/year (IQR, 0.022-0.054 mm/year). This rate for males was 0.049 mm/year medially (IQR, 0.042-0.077 mm/year) and 0.032 mm/year laterally (IQR, 0.026-0.059 mm/year), and for females was 0.027 mm/year medially (0.016-0.039 mm/year) and 0.020 mm/year laterally (IQR, 0.013-0.032 mm/year). The wear rate for males was greater medially (difference = 0.022 mm/year, p < 0.001) and laterally (difference = 0.012 mm/year, p = 0.008). There were associations between greater wear and increasing height (ρ = 0.48, p < 0.001 medially and ρ = 0.30, p = 0.04 laterally), decreasing body mass index (ρ = -0.31, p = 0.03 medially), and greater implant size (ρ = 0.34, p = 0.02 medially). Increasingly varus leg alignment was associated with greater medial wear (ρ = 0.33, p = 0.02). CONCLUSIONS: Greater wear rates were associated with demographic factors and leg alignment. Further RSA wear studies of other modern implant systems would provide complementary information to retrieval studies and valuable data on wear resistance. CLINICAL RELEVANCE: Good wear resistance was demonstrated by well-performing implants in patients at long-term followup with wear magnitudes in agreement with reported values from retrieval studies.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Análisis Radioestereométrico , Tomografía Computarizada por Rayos X , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Fenómenos Biomecánicos , Femenino , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiopatología , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Diseño de Prótesis , Rango del Movimiento Articular , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Estrés Mecánico , Factores de Tiempo , Resultado del Tratamiento
18.
J Arthroplasty ; 34(5): 932-938, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30745083

RESUMEN

BACKGROUND: The purpose of this study is to compare surgical and clinical outcomes between matched groups of morbidly obese (body mass index [BMI] >40 kg/m2) and non-morbidly obese (BMI <40 kg/m2) patients undergoing first-time revision total knee arthroplasty with a minimum 5-year follow-up. METHODS: Two groups of 87 patients (BMI >40 or <40 kg/m2) were matched 1:1 based on age at the time of revision, gender, and diagnosis for revision (aseptic or septic causes). RESULTS: The morbidly obese group had a significantly greater incidence of re-operation (34.5% [30/87] vs 16.1% [14/87], P = .005) and re-revision (27.6% [24/87] vs 12.6% [11/87], P = .014) with a significantly lower 10-year survivorship for re-operation (P = .05) and subsequent revision (P = .014). In particular, the aseptic sub-group had a greater incidence of re-operation (29.9% [20/67] vs 13.4% [9/67], P = .021) and re-revision (26.9% [18/67] vs 11.9% [8/67], P = .029). The non-morbidly obese group demonstrated higher final Western Ontario and McMaster Universities Index scores (63.1 ± 19.5 vs 55.5 ± 22.5, P = .030) and a greater change between pre-operative and final KSS (45.6 ± 44.3 vs 39.7 ± 48.4, P = .040) and SF-12 Mental component (3.6 ± 10.8 vs -1.4 ± 10.3, P = .013). CONCLUSION: Morbidly obese patients undergoing revision total knee arthroplasty have a greater risk of re-operation and re-revision while experiencing lower clinical outcome scores compared to non-morbidly obese patients. These patients should be informed of the higher potential for re-operation and the possibility of poor results.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/estadística & datos numéricos , Obesidad Mórbida/complicaciones , Complicaciones Posoperatorias/etiología , Reoperación/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Índice de Masa Corporal , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ontario/epidemiología , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/cirugía , Estudios Retrospectivos , Factores de Riesgo
19.
Knee Surg Sports Traumatol Arthrosc ; 26(6): 1610-1617, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29147742

RESUMEN

PURPOSE: To examine implant migration and articular behavior of primary total knee arthroplasty (TKA) at 10 years after index surgery and correlate to implant alignment. METHODS: Thirty-five patients underwent a cemented posterior stabilized total knee arthroplasty with a surgical objective of neutral alignment and were enrolled in a long-term radiostereometric analysis (RSA) study. At 10 years after surgery, patients were analyzed for implant migration using RSA as well as radiographic assessment of articular behavior at four positions of knee flexion. Implant position and alignment was measured on full-length radiographs. Patient demographics and reported outcomes were also collected. RESULTS: No difference between patient demographics or patient-reported outcomes were found. When categorized into neutral and varus groupings, no difference in migration was present. If alignment was considered as a continuous variable, there was no correlation between overall leg alignment and migration, however, migration increased with an increasing varus tibial alignment. Although contact location did not differ between neutral and varus groups through a range of motion, condylar liftoff was much more common in the varus group, of which all were lateral liftoff. CONCLUSIONS: Increased tibial varus results in increased implant migration. Overall varus limb alignment is correlated with isolated lateral compartment liftoff, and liftoff occurs more commonly than in neutral aligned knees. The increased migration and liftoff raise concerns about the longevity of malaligned total knee replacements. If a goal of overall varus limb alignment is desired for TKA, the tibia should remain neutral. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Desviación Ósea/diagnóstico por imagen , Prótesis de la Rodilla/efectos adversos , Osteoartritis de la Rodilla/cirugía , Falla de Prótesis , Tibia/cirugía , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/métodos , Fenómenos Biomecánicos , Desviación Ósea/etiología , Femenino , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico por imagen , Análisis Radioestereométrico , Rango del Movimiento Articular
20.
Clin Orthop Relat Res ; 475(12): 2970-2980, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28905208

RESUMEN

BACKGROUND: Tibial baseplate roughness and polyethylene-insert micromotion resulting from locking-mechanism loosening can lead to polyethylene backside wear in TKAs. However, many retrieval studies examining these variables have evaluated only older TKA implant designs. QUESTIONS: We used implant-retrieval analysis to examine if there were differences in: (1) backside damage scores, (2) backside damage modes, and (3) backside linear wear rates in five TKA implant designs owing to differing baseplate surface roughness and locking mechanisms. Additionally, we examined if (4) patient demographics influence backside damage and wear. METHODS: Five TKA implant models (four modern and one historical design) were selected with different tibial baseplate and/or locking mechanism designs. Six tibial inserts retrieved at the time of revision from each TKA model were matched for time in vivo, age of the patient at TKA revision, BMI, sex, revision number, and revision reason. Each insert backside was analyzed for: (1) visual total damage score and (2) individual visual damage modes, both by two observers and with an intraclass correlation coefficient of 0.66 (95% CI, 0.39-0.92), and (3) linear wear rate measured by micro-CT. Median primary outcomes were compared among the five designs. For our given sample size among five groups we could detect with 80% power a 10-point difference in damage score and an 0.11-mm per year difference in wear rate. RESULTS: The polished tibial design with a partial peripheral capture locking mechanism and anterior constraint showed a lower total damage score compared with the nonpolished tibial design with only a complete peripheral-rim locking mechanism (median, 12.5; range, 9.5-18.0; 95% CI, 9.58-16.42 versus median, 22.3; range, 15.5-27.0; 95% CI, 17.5-26.5; p = 0.019). The polished baseplate with a tongue-in-groove locking mechanism showed more abrasions than the nonpolished baseplate with a peripheral-rim capture and antirotational island (median, 7.25; range, 0.5-8.0; 95% CI, 2.67-8.99 versus median, 0.75; range, 0-1.5; 95% CI, 0.20-1.47; p = 0.016)). Dimpling was a unique wear mode to the nonpolished baseplates with the peripheral-rim capture and antirotational island (median, 5.5; range, 2.0-9.0; 95% CI, 2.96-8.38) and the peripheral-rim capture alone (median, 9.0; range, 6.0-10.0; 95% CI, 7.29-10.38). Overall, the linear wear rate for polished designs was lower than for nonpolished designs (0.0102 ± 0.0044 mm/year versus 0.0224 ± 0.0119 mm/year; p < 0.001). Two of the polished baseplate designs, the partial peripheral capture with anterior constraint (median, 0.083 mm/year; range, 0.0037-0.0111 mm/year; 95% CI, 0.0050-0.0107 mm versus median, 0.0245 mm/year; range, 0.014-0.046 mm/year; 95% CI, 0.0130-0.0414 mm; p = 0.008) and the tongue-in-groove locking mechanism (median, 0.0085 mm/year; range, 0.005-0.015 mm/year; 95% CI, 0.0045-0.0138 mm; p = 0.032) showed lower polyethylene linear wear rates compared with the nonpolished baseplate design with only a peripheral-rim capture. CONCLUSIONS: Total damage scores and linear wear rates were highest involving the nonpolished design with only a peripheral rim capture. There were no differences among the other TKA designs regarding damage and wear, but this finding should be considered in the setting of a relatively small sample size. CLINICAL RELEVANCE: Our study showed that in the complex interplay between baseplate surface finish and locking mechanism design, a polished baseplate with a robust locking mechanism had the lowest backside damage and linear wear. However, improvements in locking mechanism design in nonpolished baseplates potentially may offset some advantages of a polished baseplate. Further retrieval analyses need to be done to confirm such findings, especially analyzing current crosslinked polyethylene. Additionally, we need mid- and long-term studies comparing TKA revisions attributable to wear and osteolysis among implants before understanding if such design differences are clinically relevant.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Polietileno/química , Diseño de Prótesis , Falla de Prótesis , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Fenómenos Biomecánicos , Remoción de Dispositivos , Femenino , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiopatología , Masculino , Persona de Mediana Edad , Factores de Riesgo , Estrés Mecánico , Propiedades de Superficie , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA