Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 23 Suppl 1: e13799, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36382354

RESUMEN

This section focuses on the professional workforce comprised of the primary medical specialties that utilize ionizing radiation in their practices. Those discussed include the specialties of radiology and radiation oncology, as well as the subspecialties of radiology, namely diagnostic radiology, interventional radiology, nuclear radiology, and nuclear medicine. These professionals provide essential health care services, for example, the interpretation of imaging studies, the provision of interventional procedures, radionuclide therapeutic treatments, and radiation therapy. In addition, they may be called on to function as part of a radiologic emergency response team to care for potentially exposed persons following radiation events, for example, detonation of a nuclear weapon, nuclear power plant accidents, and transportation incidents. For these reasons, maintenance of an adequate workforce in each of these professions is essential to meeting the nation's future needs. Currently, there is a shortage for all physicians in the medical radiology workforce.


Asunto(s)
Medicina , Medicina Nuclear , Humanos , Estados Unidos , Diagnóstico por Imagen , Radiología Intervencionista , Recursos Humanos
2.
Radiat Environ Biophys ; 59(3): 389-405, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32556631

RESUMEN

Myriad radiation effects, including benefits and detriments, complicate justifying and optimizing radiation exposures. The purpose of this study was to develop a comprehensive conceptual framework and corresponding quantitative methods to aggregate the detriments and benefits of radiation exposures to individuals, groups, and populations. In this study, concepts from the ICRP for low dose were integrated with clinical techniques focused on high dose to develop a comprehensive figure of merit (FOM) that takes into account arbitrary host- and exposure-related factors, endpoints, and time points. The study built on existing methods with three new capabilities: application to individuals, groups, and populations; extension to arbitrary numbers and types of endpoints; and inclusion of limitation, where relevant. The FOM was applied to three illustrative exposure situations: emergency response, diagnostic imaging, and cancer radiotherapy, to evaluate its utility in diverse settings. The example application to radiation protection revealed the FOM's utility in optimizing the benefits and risks to a population while keeping individual exposures below applicable regulatory limits. Examples in diagnostic imaging and cancer radiotherapy demonstrated the FOM's utility for guiding population- and patient-specific decisions in medical applications. The major finding of this work is that it is possible to quantitatively combine the benefits and detriments of any radiation exposure situation involving an individual or population to perform cost-effectiveness analyses using the ICRP key principles of radiation protection. This FOM fills a chronic gap in the application of radiation-protection theory, i.e., limitations of generalized frameworks to algorithmically justify and optimize radiation exposures. This new framework potentially enhances objective optimization and justification, especially in complex exposure situations.


Asunto(s)
Exposición a la Radiación , Protección Radiológica , Socorristas , Humanos , Neoplasias/radioterapia , Dosis de Radiación , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/análisis , Liberación de Radiactividad Peligrosa , Radiografía
9.
Radiat Meas ; 58: 37-44, 2013 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-25147474

RESUMEN

Monte Carlo simulations are increasingly used for dose calculations in proton therapy due to its inherent accuracy. However, dosimetric deviations have been found using Monte Carlo code when high density materials are present in the proton beam line. The purpose of this work was to quantify the magnitude of dose perturbation caused by metal objects. We did this by comparing measurements and Monte Carlo predictions of dose perturbations caused by the presence of small metal spheres in several clinical proton therapy beams as functions of proton beam range, spread-out Bragg peak width and drift space. Monte Carlo codes MCNPX, GEANT4 and Fast Dose Calculator (FDC) were used. Generally good agreement was found between measurements and Monte Carlo predictions, with the average difference within 5% and maximum difference within 17%. The modification of multiple Coulomb scattering model in MCNPX code yielded improvement in accuracy and provided the best overall agreement with measurements. Our results confirmed that Monte Carlo codes are well suited for predicting multiple Coulomb scattering in proton therapy beams when short drift spaces are involved.

10.
Nucl Technol ; 183(1): 101-106, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25435594

RESUMEN

Monte Carlo simulations are increasingly used to reconstruct dose distributions in radiotherapy research studies. Many studies have used the MCNPX Monte Carlo code with a mesh tally for dose reconstructions. However, when the number of voxels in the simulated patient anatomy is large, the computation time for a mesh tally can become prohibitively long. The purpose of this work was to test the feasibility of using lattice tally instead of mesh tally for whole-body dose reconstructions. We did this by comparing the dosimetric accuracy and computation time of lattice tallies with those of mesh tallies for craniospinal proton irradiation. The two tally methods generated nearly identical dosimetric results, within 1% in dose and within 1 mm distance-to-agreement for 99% of the voxels. For a typical craniospinal proton treatment field, simulation speed was 4 to 17 times faster using the lattice tally than using the mesh tally, depending on the numbers of proton histories and voxels. We conclude that the lattice tally is an acceptable substitute for the mesh tally in dose reconstruction, making it a suitable potential candidate for clinical treatment planning.

11.
J Cancer Educ ; 27(2 Suppl): S128-35, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22314794

RESUMEN

As part of a 2-day conference on October 15 and 16, 2009, a nine-member task force composed of scientists, clinicians, educators, administrators, and students from across the USA was formed to discuss research, discovery, and technology obstacles to progress in cancer prevention and control, specifically those related to the cancer prevention workforce. This article summarizes the task force's findings on the current state of the cancer prevention workforce in this area and its needs for the future. The task force identified two types of barriers impeding the current cancer prevention workforce in research, discovery, and technology from reaching its fullest potential: (1) limited cross-disciplinary research opportunities with underutilization of some disciplines is hampering discovery and research in cancer prevention, and (2) new research avenues are not being investigated because technology development and implementation are lagging. Examples of impediments and desired outcomes are provided in each of these areas. Recommended solutions to these problems are based on the goals of enhancing the current cancer prevention workforce and accelerating the pace of discovery and clinical translation.


Asunto(s)
Investigación Biomédica , Tecnología Biomédica , Necesidades y Demandas de Servicios de Salud/organización & administración , Oncología Médica , Neoplasias/prevención & control , Guías de Práctica Clínica como Asunto , Competencia Profesional , Congresos como Asunto , Humanos , Oncología Médica/educación , Neoplasias/diagnóstico , Recursos Humanos
12.
Phys Med Biol ; 67(12)2022 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-35613603

RESUMEN

Objective. Patients who receive proton beam therapy are exposed to unwanted stray neutrons. Stray radiations increase the risk of late effects in normal tissues, such as second cancers and cataracts, and may cause implanted devices such as pacemakers to malfunction. Compared to therapeutic beams, little attention has been paid to modeling stray neutron exposures. In the past decade, substantial progress was made to develop semiempirical models of stray neutron dose equivalent, but models to routinely calculate neutron absorbed dose and kerma are still lacking. The objective of this work was to develop a new physics based analytical model to calculate neutron spectral fluence, kerma, and absorbed dose in a water phantom.Approach. We developed the model using dosimetric data from Monte Carlo simulations and neutron kerma coefficients from the literature. The model explicitly considers the production, divergence, scattering, and attenuation of neutrons. Neutron production was modeled for 120-250 MeV proton beams impinging on a variety of materials. Fluence, kerma and dose calculations were performed in a 30 × 180 × 44 cm3phantom at points up to 43 cm in depth and 80 cm laterally.Main Results. Predictions of the analytical model agreed reasonably with corresponding values from Monte Carlo simulations, with a mean difference in average energy deposited of 20%, average kerma coefficient of 21%, and absorbed dose to water of 49%.Significance. The analytical model is simple to implement and use, requires less configuration data that previously reported models, and is computationally fast. This model appears potentially suitable for integration in treatment planning system, which would enable risk calculations in prospective and retrospective cases, providing a powerful tool for epidemiological studies and clinical trials.


Asunto(s)
Terapia de Protones , Exposición a la Radiación , Humanos , Método de Montecarlo , Neutrones , Física , Estudios Prospectivos , Terapia de Protones/efectos adversos , Radiometría/métodos , Dosificación Radioterapéutica , Estudios Retrospectivos , Agua
13.
Biomed Phys Eng Express ; 8(2)2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-35045408

RESUMEN

The objective of this study was to confirm the feasibility of three-dimensionally-printed (3D-printed), personalized whole-body anthropomorphic phantoms for radiation dose measurements in a variety of charged and uncharged particle radiation fields. We 3D-printed a personalized whole-body phantom of an adult female with a height of 154.8 cm, mass of 90.7 kg, and body mass index of 37.8 kg/m2. The phantom comprised of a hollow plastic shell filled with water and included a watertight access conduit for positioning dosimeters. It is compatible with a wide variety of radiation dosimeters, including ionization chambers that are suitable for uncharged and charged particles. Its mass was 6.8 kg empty and 98 kg when filled with water. Watertightness and mechanical robustness were confirmed after multiple experiments and transportations between institutions. The phantom was irradiated to the cranium with therapeutic beams of 170-MeV protons, 6-MV photons, and fast neutrons. Radiation absorbed dose was measured from the cranium to the pelvis along the longitudinal central axis of the phantom. The dose measurements were made using established dosimetry protocols and well-characterized instruments. For the therapeutic environments considered in this study, stray radiation from intracranial treatment beams was the lowest for proton therapy, intermediate for photon therapy, and highest for neutron therapy. An illustrative example set of measurements at the location of the thyroid for a square field of 5.3 cm per side resulted in 0.09, 0.59, and 1.93 cGy/Gy from proton, photon, and neutron beams, respectively. In this study, we found that 3D-printed personalized phantoms are feasible, inherently reproducible, and well-suited for therapeutic radiation measurements. The measurement methodologies we developed enabled the direct comparison of radiation exposures from neutron, proton, and photon beam irradiations.


Asunto(s)
Fotones , Protones , Adulto , Femenino , Humanos , Neutrones , Impresión Tridimensional , Agua
14.
Phys Med Biol ; 66(6): 065007, 2021 03 04.
Artículo en Inglés | MEDLINE | ID: mdl-33545710

RESUMEN

Research in cancer care increasingly focuses on survivorship issues, e.g. managing disease- and treatment-related morbidity and mortality occurring during and after treatment. This necessitates innovative approaches that consider treatment side effects in addition to tumor cure. Current treatment-planning methods rely on constrained iterative optimization of dose distributions as a surrogate for health outcomes. The goal of this study was to develop a generally applicable method to directly optimize projected health outcomes. We developed an outcome-based objective function to guide selection of the number, angle, and relative fluence weight of photon and proton radiotherapy beams in a sample of ten prostate-cancer patients by optimizing the projected health outcome. We tested whether outcome-optimized radiotherapy (OORT) improved the projected longitudinal outcome compared to dose-optimized radiotherapy (DORT) first for a statistically significant majority of patients, then for each individual patient. We assessed whether the results were influenced by the selection of treatment modality, late-risk model, or host factors. The results of this study revealed that OORT was superior to DORT. Namely, OORT maintained or improved the projected health outcome of photon- and proton-therapy treatment plans for all ten patients compared to DORT. Furthermore, the results were qualitatively similar across three treatment modalities, six late-risk models, and 10 patients. The major finding of this work was that it is feasible to directly optimize the longitudinal (i.e. long- and short-term) health outcomes associated with the total (i.e. therapeutic and stray) absorbed dose in all of the tissues (i.e. healthy and diseased) in individual patients. This approach enables consideration of arbitrary treatment factors, host factors, health endpoints, and times of relevance to cancer survivorship. It also provides a simpler, more direct approach to realizing the full beneficial potential of cancer radiotherapy.


Asunto(s)
Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Terapia de Protones/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Anciano , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Fotones , Fenómenos Físicos , Radioterapia de Intensidad Modulada/métodos , Resultado del Tratamiento
15.
Med Phys ; 48(1): e1-e30, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33078858

RESUMEN

Proton therapy is an expanding radiotherapy modality in the United States and worldwide. With the number of proton therapy centers treating patients increasing, so does the need for consistent, high-quality clinical commissioning practices. Clinical commissioning encompasses the entire proton therapy system's multiple components, including the treatment delivery system, the patient positioning system, and the image-guided radiotherapy components. Also included in the commissioning process are the x-ray computed tomography scanner calibration for proton stopping power, the radiotherapy treatment planning system, and corresponding portions of the treatment management system. This commissioning report focuses exclusively on intensity-modulated scanning systems, presenting details of how to perform the commissioning of the proton therapy and ancillary systems, including the required proton beam measurements, treatment planning system dose modeling, and the equipment needed.


Asunto(s)
Terapia de Protones , Radioterapia de Intensidad Modulada , Calibración , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
16.
Radiat Meas ; 45(10): 1367-1368, 2010 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-21544230

RESUMEN

Treatment planning in proton therapy requires the calculation of absorbed dose distributions on beam shaping components and the patient anatomy. Analytical pencil-beam dose algorithms commonly used are not always accurate enough. The Monte Carlo approach is more accurate but extremely computationally intensive. The Fast Dose Calculator, a track-repeating algorithm, has been proposed as an alternative fast and accurate dose calculation. In this work FDC is applied to a proton therapy patient thoracic anatomy.

17.
Biomed Phys Eng Express ; 6(5): 055028, 2020 10 21.
Artículo en Inglés | MEDLINE | ID: mdl-33444259

RESUMEN

The human body contains approximately 20 billion blood vessels, which transport nutrients, oxygen, immune cells, and signals throughout the body. The brain's vasculature includes up to 9 billion of these vessels to support cognition, motor processes, and myriad other vital functions. To model blood flowing through a vasculature, a geometric description of the vessels is required. Previously reported attempts to model vascular geometries have produced highly-detailed models. These models, however, are limited to a small fraction of the human brain, and little was known about the feasibility of computationally modeling whole-organ-sized networks. We implemented a fractal-based algorithm to construct a vasculature the size of the human brain and evaluated the algorithm's speed and memory requirements. Using high-performance computing systems, the algorithm constructed a vasculature comprising 17 billion vessels in 1960 core-hours, or 49 minutes of wall-clock time, and required less than 32 GB of memory per node. We demonstrated strong scalability that was limited mainly by input/output operations. The results of this study demonstrated, for the first time, that it is feasible to computationally model the vasculature of the whole human brain. These findings provide key insights into the computational aspects of modeling whole-organ vasculature.


Asunto(s)
Algoritmos , Encéfalo/fisiología , Circulación Cerebrovascular , Biología Computacional/métodos , Simulación por Computador , Hemodinámica , Estudios de Factibilidad , Humanos
18.
Biomed Phys Eng Express ; 6(5): 055027, 2020 10 21.
Artículo en Inglés | MEDLINE | ID: mdl-33444258

RESUMEN

Vasculature is necessary to the healthy function of most tissues. In radiation therapy, injury of the vasculature can have both beneficial and detrimental effects, such as tumor starvation, cardiac fibrosis, and white-matter necrosis. These effects are caused by changes in blood flow due to the vascular injury. Previously, research has focused on simulating the radiation injury of vasculature in small volumes of tissue, ignoring the systemic effects of local damage on blood flow. Little is known about the computational feasibility of simulating the radiation injury to whole-organ vascular networks. The goal of this study was to test the computational feasibility of simulating the dose deposition to a whole-organ vascular network and the resulting change in blood flow. To do this, we developed an amorphous track-structure model to transport radiation and combined this with existing methods to model the vasculature and blood flow rates. We assessed the algorithm's computational scalability, execution time, and memory usage. The data demonstrated it is computationally feasible to calculate the radiation dose and resulting changes in blood flow from 2 million protons to a network comprising 8.5 billion blood vessels (approximately the number in the human brain) in 87 hours using a 128-node cluster. Furthermore, the algorithm demonstrated both strong and weak scalability, meaning that additional computational resources can reduce the execution time further. These results demonstrate, for the first time, that it is computationally feasible to calculate radiation dose deposition in whole-organ vascular networks. These findings provide key insights into the computational aspects of modeling whole-organ radiation damage. Modeling the effects radiation has on vasculature could prove useful in the study of radiation effects on tissues, organs, and organisms.


Asunto(s)
Algoritmos , Vasos Sanguíneos/efectos de la radiación , Sistema Cardiovascular/patología , Circulación Cerebrovascular/efectos de la radiación , Simulación por Computador , Hemodinámica , Traumatismos por Radiación/fisiopatología , Sistema Cardiovascular/efectos de la radiación , Biología Computacional , Estudios de Factibilidad , Humanos , Protones/efectos adversos , Traumatismos por Radiación/etiología
19.
Biomed Phys Eng Express ; 6(5): 055026, 2020 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-33444257

RESUMEN

The human body contains approximately 20 billion individual blood vessels that deliver nutrients and oxygen to tissues. While blood flow is a well-developed field of research, no previous studies have calculated the blood flow rates through more than 5 million connected vessels. The goal of this study was to test if it is computationally feasible to calculate the blood flow rates through a vasculature equal in size to that of the human body. We designed and implemented a two-step algorithm to calculate the blood flow rates using principles of steady-state fluid dynamics. Steady-state fluid dynamics is an accurate approximation for the microvascular and venous structures in the human body. To determine the computational feasibility, we measured and evaluated the execution time, scalability, and memory usage to quantify the computational requirements. We demonstrated that it is computationally feasible to calculate the blood flow rate through 17 billion vessels in 6.5 hours using 256 compute nodes. The computational modeling of blood flow rate in entire organisms may find application in research on drug delivery, treatment of cancer metastases, and modulation of physiological performance.


Asunto(s)
Algoritmos , Sistema Cardiovascular/fisiopatología , Simulación por Computador , Cuerpo Humano , Microvasos/fisiología , Modelos Cardiovasculares , Velocidad del Flujo Sanguíneo , Estudios de Factibilidad , Humanos , Hidrodinámica
20.
Med Phys ; 47(5): 2254-2266, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31943237

RESUMEN

PURPOSE: Photon radiotherapy techniques typically devote considerable attention to limiting the exposure of healthy tissues outside of the target volume. Numerous studies have shown, however, that commercial treatment planning systems (TPSs) significantly underestimate the absorbed dose outside of the treatment field. The purpose of this study was to test the feasibility of quickly and accurately calculating the total absorbed dose to the whole body from photon radiotherapy in individual patients. METHODS: We created an extended TPS by implementing a physics-based analytical model for the absorbed dose from stray photons during photon therapy into a research TPS. We configured and validated the extended TPS using measurements of 6- and 15-MV photon beams in water-box and anthropomorphic phantoms. We characterized the additional computation time required for therapeutic and stray dose calculations in a 44 × 30 × 180 cm3 water-box phantom. RESULTS: The extended TPS achieved superior dosimetric accuracy compared to the research TPS in both water and anthropomorphic phantoms, especially outside of the primary treatment field. In the anthropomorphic phantom, the extended TPS increased the generalized gamma index passing rate by a factor of 10 and decreased the median dosimetric discrepancy in the out-of-field region by a factor of 26. The extended TPS achieved an average discrepancy <1% in and near the treatment field and <1 mGy/Gy far from the treatment field in the anthropomorphic phantom. Characterization of computation time revealed that on average, the extended TPS only required 7% longer than the research TPS to calculate the total absorbed dose. CONCLUSIONS: The results of this work suggest that it is feasible to quickly and accurately calculate whole-body doses inside and outside of the therapeutic treatment field in individual patients on a routine basis using physics-based analytical dose models. This additional capability enables a more personalized approach to minimizing the risk of radiogenic late effects, such as second cancer and cardiac toxicity, as part of the treatment planning process.


Asunto(s)
Absorción de Radiación , Fotones/uso terapéutico , Radiometría/métodos , Humanos , Fotones/efectos adversos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA