Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Med Phys ; 41(9): 091501, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25186375

RESUMEN

The radiation dose involved in any medical imaging modality that uses ionizing radiation needs to be well understood by the medical physics and clinical community. This is especially true of screening modalities. Digital breast tomosynthesis (DBT) has recently been introduced into the clinic and is being used for screening for breast cancer in the general population. Therefore, it is important that the medical physics community have the required information to be able to understand, estimate, and communicate the radiation dose levels involved in breast tomosynthesis imaging. For this purpose, the American Association of Physicists in Medicine Task Group 223 on Dosimetry in Tomosynthesis Imaging has prepared this report that discusses dosimetry in breast imaging in general, and describes a methodology and provides the data necessary to estimate mean breast glandular dose from a tomosynthesis acquisition. In an effort to maximize familiarity with the procedures and data provided in this Report, the methodology to perform the dose estimation in DBT is based as much as possible on that used in mammography dose estimation.


Asunto(s)
Mamografía/métodos , Intensificación de Imagen Radiográfica/métodos , Radiometría/métodos , Algoritmos , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/diagnóstico por imagen , Simulación por Computador , Humanos , Mamografía/instrumentación , Modelos Biológicos , Método de Montecarlo , Intensificación de Imagen Radiográfica/instrumentación , Sociedades Médicas , Estados Unidos
2.
Cardiovasc Intervent Radiol ; 31(2): 281-8, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18026792

RESUMEN

The purpose of this study was to assess the usefulness of a three-dimensional (3D) angiography system using a flat panel detector of direct conversion type in treatments with subsegmental transcatheter arterial chemoembolization (TACE) for hepatocellular carcinomas (HCCs). Thirty-six consecutive patients who underwent hepatic angiography were prospectively examined. First, two radiologists evaluated the degree of visualization of the peripheral branches of the hepatic arteries on 3D digital subtraction angiography (DSA). Then the radiologists evaluated the visualization of tumor staining and feeding arteries in 25 patients (30 HCCs) who underwent subsegmental TACE. The two radiologists who performed the TACE assessed whether the additional information provided by 3D DSA was useful for treatments. In 34 (94.4%) of 36 patients, the subsegmental branches of the hepatic arteries were sufficiently visualized. The feeding arteries of HCCs were sufficiently visualized in 28 (93%) of 30 HCCs, whereas tumor stains were sufficiently visualized in 18 (60%). Maximum intensity projection images were significantly superior to volume recording images for visualization of the tumor staining and feeding arteries of HCCs. In 27 (90%) of 30 HCCs, 3D DSA provided additional useful information for subsegmental TACE. The high-quality 3D DSA with flat panel detector angiography system provided a precise vascular road map, which was useful for performing subsegmental TACE of HCCs.


Asunto(s)
Angiografía/métodos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/métodos , Imagenología Tridimensional , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Adulto , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Artefactos , Niño , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Intensificación de Imagen Radiográfica/instrumentación , Interpretación de Imagen Radiográfica Asistida por Computador , Estadísticas no Paramétricas , Resultado del Tratamiento
3.
J Vasc Interv Radiol ; 18(12): 1508-16, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18057285

RESUMEN

PURPOSE: To assess the usefulness of cone-beam volume computed tomography (CT) (cone-beam CT) with use of flat panel detectors of the direct conversion type in conjunction with conventional digital subtraction angiography (DSA) in the diagnosis and treatment of patients with hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Forty-nine consecutive patients (52 suspicious lesions) were prospectively examined. All patients underwent intraarterial rotational angiography with a flat panel detector system, and the cone-beam CT scans were reconstructed from the volume data set. The authors evaluated the diagnostic quality of cone-beam CT for the transcatheter arterial chemoembolization (TACE) procedure. RESULTS: The diagnostic quality of conventional DSA plus cone-beam CT with regard to tumor staining was superior to that of DSA alone. Cone-beam CT showed tumor staining in five lesions that were difficult to diagnose with confidence on the basis of the DSA findings alone. The extent of contrast medium perfusion was sufficiently visualized on all cone-beam CT scans at the tip of the catheter positioned in either the segmental or subsegmental hepatic arteries. In 42 of the 52 lesions (81%), cone-beam CT provided additional useful information for therapeutic decision making or TACE compared with DSA. CONCLUSIONS: Intraarterial cone-beam CT with a flat panel detector can provide clinically acceptable image quality in the assessment of HCC, thereby improving the detection of tumor staining due to HCC and the visualization of the extent of contrast medium perfusion.


Asunto(s)
Angiografía de Substracción Digital/instrumentación , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/métodos , Arteria Hepática , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Radiografía Intervencional/instrumentación , Tomografía Computarizada por Rayos X/instrumentación , Pantallas Intensificadoras de Rayos X , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital/métodos , Antibióticos Antineoplásicos/administración & dosificación , Medios de Contraste , Epirrubicina/administración & dosificación , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Esponja de Gelatina Absorbible/administración & dosificación , Humanos , Aceite Yodado/administración & dosificación , Yopamidol/uso terapéutico , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/instrumentación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
4.
Eur Radiol ; 16(11): 2594-602, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16708219

RESUMEN

The purpose of this study was to compare the image quality of two-dimensional (2D) digital subtraction angiography (DSA) between a flat panel detector (FPD) of the direct conversion type with low radiation dose and a conventional image intensifier (I.I.)-TV system, and to assess 3D DSA with the FPD system in the depiction of intracranial vessels. Fifteen consecutive patients (five men, ten women; age range: 18-82 years; mean age: 55.5 years) were prospectively included in this study. All patients underwent 2D DSA with both the FPD and I.I.-TV system in one projection. The radiation doses during angiography were evaluated using a phantom. The 3D DSA images were created from the rotational DSA data with the FPD system. Two blinded radiologists independently evaluated 2D DSA with the FPD system and I.I.-TV system using a 5-point assessment scale (excellent to not visible) to assess the depiction of intracranial vessels. MIP and volume rendering (VR) images of 3D DSA with the FPD system were also evaluated using a 5-point scale (excellent to not visible). DSA and fluoroscopy dose measurements with the phantom showed a dose reduction of approximately 85% and 9% with the FPD system compared with the I.I.-TV system, respectively. For 2D DSA, the FPD system was significantly superior to the I.I.-TV system with respect to the visibility of the peripheral and perforating vessels (p<0.05). The peripheral and perforating vessels were also sufficiently visualized on MIP images of 3D DSA in all 15 cases. Our FPD system was found to be superior to the I.I.-TV system in visualizing small intracranial vessels combined with a significant reduction of radiation dose, and was able to create high-quality 3D DSA images on which high spatial resolution allowed precise visualization of small vessels such as perforating ones.


Asunto(s)
Angiografía de Substracción Digital , Encefalopatías/diagnóstico por imagen , Encefalopatías/patología , Angiografía Cerebral , Procesamiento de Imagen Asistido por Computador , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Aneurisma Roto/diagnóstico por imagen , Aneurisma Roto/patología , Angiografía de Substracción Digital/métodos , Arteria Carótida Interna/diagnóstico por imagen , Arteria Carótida Interna/patología , Angiografía Cerebral/métodos , Enfermedades Arteriales Cerebrales/diagnóstico por imagen , Enfermedades Arteriales Cerebrales/patología , Simulación por Computador , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/patología , Masculino , Meningioma/diagnóstico por imagen , Meningioma/patología , Persona de Mediana Edad , Variaciones Dependientes del Observador , Fantasmas de Imagen , Estudios Prospectivos , Dosis de Radiación , Proyectos de Investigación , Estadísticas no Paramétricas , Hemorragia Subaracnoidea/diagnóstico por imagen , Hemorragia Subaracnoidea/patología , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA