Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Lancet Infect Dis ; 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38734012

RESUMEN

BACKGROUND: Lassa fever is a viral haemorrhagic fever with few options for diagnosis and treatment; it is also under-researched with knowledge gaps on its epidemiology. A point-of-care bedside test diagnosing Lassa fever, adhering to REASSURED criteria, is not currently available but is urgently needed in west African regions with high Lassa fever burden. We aimed to assess the validity and feasibility of a rapid diagnostic test (RDT) to confirm Lassa fever in people in Nigeria. METHODS: We estimated the diagnostic performance of the ReLASV Pan-Lassa RDT (Zalgen Labs, Frederick, MD, USA) as a research-use-only test, compared to RT-PCR as a reference standard, in 217 participants at a federal tertiary hospital in Abakaliki, Nigeria. We recruited participants between Feb 17, 2022, and April 17, 2023. The RDT was performed using capillary blood at the patient bedside and using plasma at the laboratory. The performance of the test, based on REASSURED criteria, was assessed for user friendliness, rapidity and robustness, sensitivity, and specificity. FINDINGS: Participants were aged between 0 and 85 years, with a median age of 33·0 years (IQR 22·0-44·3), and 24 participants were younger than 18 years. 107 (50%) participants were women and 109 (50%) were men; one participant had missing sex data. Although the specificity of the Pan-Lassa RDT was high (>90%), sensitivity at bedside using capillary blood was estimated as 4% (95% CI 1-14) at 15 min and 10% (3-22) at 25 min, far below the target of 90%. The laboratory-based RDT using plasma showed better sensitivity (46% [32-61] at 15 min and 50% [36-64] at 25 min) but did not reach the target sensitivity. Among the 52 PCR-positive participants with Lassa fever, positive RDT results were associated with lower cycle threshold values (glycoprotein precursor [GPC] gene mean 30·3 [SD 4·3], Large [L] gene mean 32·3 [3·7] vs GPC gene mean 24·5 [3·9], L gene mean 28·0 [3·6]). Personnel conducting the bedside test procedure reported being hindered by the inconvenient use of full personal protective equipment and long waiting procedures before a result could be read. INTERPRETATION: The Pan-Lassa RDT is not currently recommended as a diagnostic or screening tool for suspected Lassa fever cases. Marked improvement in sensitivity and user friendliness is needed for the RDT to be adopted clinically. There remains an urgent need for better Lassa fever diagnostics to promote safety of in-hospital care and better disease outcomes in low-resource settings. FUNDING: Médecins Sans Frontières.

2.
Front Immunol ; 15: 1305586, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38322252

RESUMEN

Introduction: One of the unexpected outcomes of the COVID-19 pandemic was the relatively low levels of morbidity and mortality in Africa compared to the rest of the world. Nigeria, Africa's most populous nation, accounted for less than 0.01% of the global COVID-19 fatalities. The factors responsible for Nigeria's relatively low loss of life due to COVID-19 are unknown. Also, the correlates of protective immunity to SARS-CoV-2 and the impact of pre-existing immunity on the outcome of the COVID-19 pandemic in Africa are yet to be elucidated. Here, we evaluated the natural and vaccine-induced immune responses from vaccinated, non-vaccinated and convalescent individuals in Southern Nigeria throughout the three waves of the COVID-19 pandemic in Nigeria. We also examined the pre-existing immune responses to SARS-CoV-2 from samples collected prior to the COVID-19 pandemic. Methods: We used spike RBD and N- IgG antibody ELISA to measure binding antibody responses, SARS-CoV-2 pseudotype assay protocol expressing the spike protein of different variants (D614G, Delta, Beta, Omicron BA1) to measure neutralizing antibody responses and nucleoprotein (N) and spike (S1, S2) direct ex vivo interferon gamma (IFNγ) T cell ELISpot to measure T cell responses. Result: Our study demonstrated a similar magnitude of both binding (N-IgG (74% and 62%), S-RBD IgG (70% and 53%) and neutralizing (D614G (49% and 29%), Delta (56% and 47%), Beta (48% and 24%), Omicron BA1 (41% and 21%)) antibody responses from symptomatic and asymptomatic survivors in Nigeria. A similar magnitude was also seen among vaccinated participants. Interestingly, we revealed the presence of preexisting binding antibodies (N-IgG (60%) and S-RBD IgG (44%)) but no neutralizing antibodies from samples collected prior to the pandemic. Discussion: These findings revealed that both vaccinated, non-vaccinated and convalescent individuals in Southern Nigeria make similar magnitude of both binding and cross-reactive neutralizing antibody responses. It supported the presence of preexisting binding antibody responses among some Nigerians prior to the COVID-19 pandemic. Lastly, hybrid immunity and heterologous vaccine boosting induced the strongest binding and broadly neutralizing antibody responses compared to vaccine or infection-acquired immunity alone.


Asunto(s)
COVID-19 , Pueblo de África Occidental , Humanos , Anticuerpos Neutralizantes , Anticuerpos ampliamente neutralizantes , COVID-19/inmunología , Ensayo de Immunospot Ligado a Enzimas , Inmunoglobulina G , Nigeria , Pandemias , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA