Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 46(9): 1049-1055, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37527153

RESUMEN

BACKGROUND: Intermittent ventricular pre-excitation was considered a low-risk marker for sudden death. However, to date, some studies do not exclude the existence of accessory pathways (APs) with high-risk intermittent antegrade conductive properties. According to current European Guidelines, high-risk features of APs are antegrade pathway conduction ≤250 ms in baseline or during the adrenergic stimulus, inducibility of atrioventricular reciprocating tachycardias (AVRT), inducibility of pre-excited atrial fibrillation (AF), and presence of multiple APs. For all of these transcatheter ablation is recommended. The aim of our study was to evaluate the existence of differences in risk characteristics between patients with intermittent pre-excitation (IPX) and those with persistent pre-excitation (PPX), from a sample of adults with ventricular pre-excitation and symptoms like palpitations. METHODS: 293 adults [IPX: 51 (17.4%); PPX: 242 (82.6%)] underwent electrophysiological study and then catheter ablation of their APs if arrhythmia inducibility (AVRT/AF) was noted, or, conversely, if it was appreciated a fast AP antegrade conduction, in baseline or during intravenous isoproterenol infusion, or if multiple APs were detected. RESULTS: There were no statistically significant differences in demographic characteristics (age and gender), AVRT/AF inducibility, antegrade conductive properties, the prevalence of multiple APs, and APs locations between IPX and PPX patients. CONCLUSIONS: In our study, patients with IPX did not show significant differences in clinical and electrophysiological features versus PPX patients.


Asunto(s)
Fascículo Atrioventricular Accesorio , Fibrilación Atrial , Ablación por Catéter , Síndromes de Preexcitación , Síndrome de Wolff-Parkinson-White , Humanos , Adulto , Fascículo Atrioventricular Accesorio/cirugía , Fibrilación Atrial/cirugía , Factores de Riesgo , Electrocardiografía
2.
Heart Vessels ; 38(5): 680-688, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36418560

RESUMEN

No real-world data are available about the complications rate in drug-induced type 1 Brugada Syndrome (BrS) patients with an implantable cardioverter-defibrillator (ICD). Aim of our study is to compare the device-related complications, infections, and inappropriate therapies among drug-induced type 1 BrS patients with transvenous- ICD (TV-ICD) versus subcutaneous-ICD (S-ICD). Data for this study were sourced from the IBRYD (Italian BRugada sYnDrome) registry which includes 619 drug-induced type-1 BrS patients followed at 20 Italian tertiary referral hospitals. For the present analysis, we selected 258 consecutive BrS patients implanted with ICD. 198 patients (76.7%) received a TV-ICD, while 60 a S-ICD (23.4%). And were followed-up for a median time of 84.3 [46.5-147] months. ICD inappropriate therapies were experienced by 16 patients (6.2%). 14 patients (7.1%) in the TVICD group and 2 patients (3.3%) in S-ICD group (log-rank P = 0.64). ICD-related complications occurred in 31 patients (12%); 29 (14.6%) in TV-ICD group and 2 (3.3%) in S-ICD group (log-rank P = 0.41). ICD-related infections occurred in 10 patients (3.88%); 9 (4.5%) in TV-ICD group and 1 (1.8%) in S-ICD group (log-rank P = 0.80). After balancing for potential confounders using the propensity score matching technique, no differences were found in terms of clinical outcomes between the two groups. In a real-world setting of drug-induced type-1 BrS patients with ICD, no significant differences in inappropriate ICD therapies, device-related complications, and infections were shown among S-ICD vs TV-ICD. However, a reduction in lead-related complications was observed in the S-ICD group. In conclusion, our evidence suggests that S-ICD is at least non-inferior to TV-ICD in this population and may also reduce the risk of lead-related complications which can expose the patients to the necessity of lead extractions.


Asunto(s)
Síndrome de Brugada , Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Síndrome de Brugada/etiología , Puntaje de Propensión , Cardioversión Eléctrica/efectos adversos , Electrocardiografía/métodos , Muerte Súbita Cardíaca/epidemiología , Resultado del Tratamiento
3.
Indian Pacing Electrophysiol J ; 20(6): 243-249, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32768620

RESUMEN

PURPOSE: Electroanatomical mapping (EAM) could increase cardiac magnetic resonance imaging (CMR) sensitivity in detecting ventricular scar. Possible bias may be scar over-estimation due to inadequate tissue contact. Aim of the study is to evaluate contact-force monitoring influence during EAM, in patients with idiopathic right ventricular arrhythmias. METHODS: 20 pts (13 M; 43 ± 12 y) with idiopathic right ventricular outflow tract (RVOT) arrhythmias and no structural abnormalities were submitted to Smarttouch catheter Carto3 EAM. Native maps included points collected without considering contact-force. EAM scar was defined as area ≥1 cm2 including at least 3 adjacent points with signal amplitude (bipolar <0.5 mV, unipolar 3,5 mV), surrounded by low-voltage border zone. EAM were re-evaluated offline, removing points collected with contact force <5 g. Finally, contact force-corrected maps were compared to the native ones. RESULTS: An EAM was created for each patient (345 ± 85 points). After removing poor contact points, a mean of 149 ± 60 points was collected. The percentage of false scar, collected during contact force blinded mapping compared to total volume, was 6.0 ± 5.2% for bipolar scar and 7.1 ± 5.9% for unipolar scar, respectively. No EAM scar was present after poor contact points removal. Right ventricular areas analysis revealed a greater number of points with contact force < 5 g acquired in free wall, where reduced mean bipolar and unipolar voltage were recorded. CONCLUSIONS: To date this is the first work conducted on structurally normal hearts in which contact-force significantly increases EAM accuracy, avoiding "false scar" related to non-adequate contact between catheter and tissue.

5.
J Electrocardiol ; 51(2): 175-181, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29174022

RESUMEN

BACKGROUND: Left bundle branch block (LBBB) and left axis deviation (LAD) patients may have poor response to resynchronization therapy (CRT). We sought to assess if LBBB and LAD patients show a specific pattern of mechanical asynchrony. METHODS: CRT candidates with non-ischemic cardiomyopathy and LBBB were categorized as having normal QRS axis (within -30° and +90°) or LAD (within -30° and -90°). Patients underwent tissue Doppler imaging (TDI) to measure time interval between onset of QRS complex and peak systolic velocity in ejection period (Q-peak) at basal segments of septal, inferior, lateral and anterior walls, as expression of local timing of mechanical activation. RESULTS: Thirty patients (mean age 70.6years; 19 males) were included. Mean left ventricular ejection fraction was 0.28±0.06. Mean QRS duration was 172.5±13.9ms. Fifteen patients showed LBBB with LAD (QRS duration 173±14; EF 0.27±0.06). The other 15 patients had LBBB with a normal QRS axis (QRS duration 172±14; EF 0.29±0.05). Among patients with LAD, Q-peak interval was significantly longer at the anterior wall in comparison to each other walls (septal 201±46ms, inferior 242±58ms, lateral 267±45ms, anterior 302±50ms; p<0.0001). Conversely, in patients without LAD Q-peak interval was longer at lateral wall, when compared to each other (septal 228±65ms, inferior 250±64ms, lateral 328±98ms, anterior 291±86ms; p<0.0001). CONCLUSIONS: Patients with heart failure, presenting LBBB and LAD, show a specific pattern of ventricular asynchrony, with latest activation at anterior wall. This finding could affect target vessel selection during CRT procedures in these patients.


Asunto(s)
Bloqueo de Rama/prevención & control , Bloqueo de Rama/fisiopatología , Terapia de Resincronización Cardíaca/métodos , Disfunción Ventricular Izquierda/prevención & control , Disfunción Ventricular Izquierda/fisiopatología , Anciano , Bloqueo de Rama/diagnóstico por imagen , Ecocardiografía Doppler , Femenino , Humanos , Masculino , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico por imagen
6.
Indian Pacing Electrophysiol J ; 18(2): 61-67, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29102650

RESUMEN

BACKGROUND: The Amigo® Remote Catheter System is a relatively new robotic system for catheter navigation. This study compared feasibility and safety using Amigo (RCM) versus manual catheter manipulation (MCM) to treat paroxysmal atrial fibrillation (PAF). Contact force (CF) and force-time integral (FTI) values obtained during pulmonary vein isolation (PVI) ablation were compared. METHODS: Forty patients were randomly selected for either RCM (20) or MCM (20). All were studied with the Thermocool® SmartTouch® force-sensing catheter (STc). Contact Force (CF), Force Time Integral (FTI) and procedure-related data, were measured/stored in the CARTO®3. RESULTS: All cases achieved complete PVI without major complications. Mean CF was significantly higher in the RCM group (13.3 ± 7.7 g in RCM vs. 12.04 ± 7.42 g in MCM p < 0.001), as was overall mean FTI (425.6 gs ± 199.6 gs with RCM and 407.5 gs ± 288.0 gs in MCM (p = 0.007) and was more likely to fall into the optimal FTI range (400-1000) using RCM (66.1% versus 49.1%, p < 0.001). FTI was significantly more likely to fall within the optimal range in each PV, as was CF within its optimal range in the right PVs, but trended higher in the left PVs. Freedom from atrial tachyarrhythmia was 90.0% for the RCM and 70.0% for the MCM group (p = 0,12) at 540 days follow-up. CONCLUSIONS: This pilot study suggests that use of the Amigo RCM system, with STc catheter, seems to be safe and effective for PVI ablation in paroxysmal AF patients. A not statistically significant favorable trend was observed for RCM in term of AF-free survival.

7.
Indian Pacing Electrophysiol J ; 18(4): 127-132, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29476904

RESUMEN

BACKGROUND: Third-generation cryoballoon (CB3) is characterized by a 40% shorter distal tip designed to increase the rate of pulmonary veins real-time signal recording in order to measure time necessary to isolate veins, the "Time to effect" (TTE). Few data are currently available on clinical follow up of CB3 treated patients. METHODS: Sixtyeight consecutive patients (mean age 57.8 ±â€¯9.6 years, 48 male) with paroxysmal or persistent atrial fibrillation (AF) were enrolled. Thirthyfour (25 paroxysmal AF) underwent to a 28 mmCB3 pulmonary veins isolation and were compared to 34 treated (21 paroxysmal AF) with 28 mmCB2. RESULTS: CB3 use was correlated to significant increase of the possibility to measure TTE in every treated veins (left superior 82,35% vs 23,53%, left inferior 70,59% vs 38,24%, right superior 58,82% vs 14,71%, right inferior 52,94% vs 17,65%). When it is measured, TTE wasn't different between two groups. Higher nadir temperature was observed in CB3 patients (-39.4 ±â€¯5.2 °C vs -43.0 ±â€¯7.2 °C, p = 0.03). CB3 procedures were shorter (91.4 ±â€¯21.7 vs 110.9 ±â€¯31.8 min, p = 0.018), with a significant reduction in cryoenergy delivery time (24.2 ±â€¯8.5 vs 20.3 ±â€¯6.7 min, p < 0.05), and a significant reduction in left atrium dwell time (59.3 ±â€¯9.8 vs 69.3 ±â€¯10.8 min, p = 0.02, p < 0.05). At one year follow up period the Kaplan-Meier curve didn't show any significant difference in AF-free survival (Log p = 0,49). CONCLUSIONS: Novel CB3 is a useful tool in order to simplify AF cryoballoon ablation when compared to second generation cryoballoon, as observed in our experience. Follow up data seem confirm a clinical CB3 efficacy at least comparable CB2.

10.
BMJ Case Rep ; 17(1)2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38216160

RESUMEN

A young competitive athlete undergoes the diagnostic investigations protocol before returning to competitive practice (return to play protocol) after COVID-19 infection. Despite the paucisymptomatic presentation of COVID-19 infection and the absence of relevant anomalies in standard first-level diagnostic investigations, echocardiographic examination findings especially speckle tracking analysis (global longitudinal strain) along with some clinical aspects suggested further second-level investigations eventually allowing the identification of inflammatory myocardial damage.


Asunto(s)
COVID-19 , Miocarditis , Humanos , Miocarditis/diagnóstico por imagen , Miocarditis/etiología , COVID-19/complicaciones , Flujo de Trabajo , Volver al Deporte , Tensión Longitudinal Global , Atletas
11.
J Cardiovasc Dev Dis ; 11(4)2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38667740

RESUMEN

Heart failure (HF) represents a significant global health challenge that is still responsible for increasing morbidity and mortality despite advancements in pharmacological treatments. This review investigates the effectiveness of non-pharmacological interventions in the management of HF, examining lifestyle measures, physical activity, and the role of some electrical therapies such as catheter ablation, cardiac resynchronization therapy (CRT), and cardiac contractility modulation (CCM). Structured exercise training is a cornerstone in this field, demonstrating terrific improvements in functional status, quality of life, and mortality risk reduction, particularly in patients with HF with reduced ejection fraction (HFrEF). Catheter ablation for atrial fibrillation, premature ventricular beats, and ventricular tachycardia aids in improving left ventricular function by reducing arrhythmic burden. CRT remains a key intervention for selected HF patients, helping achieve left ventricular reverse remodeling and improving symptoms. Additionally, the emerging therapy of CCM provides a novel opportunity for patients who do not meet CRT criteria or are non-responders. Integrating non-pharmacological interventions such as digital health alongside specific medications is key for optimizing outcomes in HF management. It is imperative to tailor approaches to individual patients in this diverse patient population to maximize benefits. Further research is warranted to improve treatment strategies and enhance patient outcomes in HF management.

12.
World J Cardiol ; 16(5): 231-239, 2024 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-38817646

RESUMEN

The use of anticoagulation therapy could prove to be controversial when trying to balance ischemic stroke and intracranial bleeding risks in patients with concurrent cerebral amyloid angiopathy (CAA) and atrial fibrillation (AF). In fact, CAA is an age-related cerebral vasculopathy that predisposes patients to intracerebral hemorrhage. Nevertheless, many AF patients require oral systemic dose-adjusted warfarin, direct oral anticoagulants (such as factor Xa inhibitors) or direct thrombin inhibitors to control often associated with cardioembolic stroke risk. The prevalence of both CAA and AF is expected to rise, due to the aging of the population. This clinical dilemma is becoming increasingly common. In patients with coexisting AF and CAA, the risks/benefits profile of anticoagulant therapy must be assessed for each patient individually due to the lack of a clear-cut consensus with regard to its risks in scientific literature. This review aims to provide an overview of the management of patients with concomitant AF and CAA and proposes the implementation of a risk-based decision-making algorithm.

13.
Eur J Prev Cardiol ; 31(4): 486-495, 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38198223

RESUMEN

AIMS: Right bundle branch block (RBBB) morphology non-sustained ventricular arrhythmias (VAs) have been associated with the presence of non-ischaemic left ventricular scar (NLVS) in athletes. The aim of this cross-sectional study was to identify clinical and electrocardiogram (ECG) predictors of the presence of NLVS in athletes with RBBB VAs. METHODS AND RESULTS: Sixty-four athletes [median age 39 (24-53) years, 79% males] with non-sustained RBBB VAs underwent cardiac magnetic resonance (CMR) with late gadolinium enhancement in order to exclude the presence of a concealed structural heart disease. Thirty-six athletes (56%) showed NLVS at CMR and were assigned to the NLVS positive group, whereas 28 athletes (44%) to the NLVS negative group. Family history of cardiomyopathy and seven different ECG variables were statistically more prevalent in the NLVS positive group. At univariate analysis, seven ECG variables (low QRS voltages in limb leads, negative T waves in inferior leads, negative T waves in limb leads I-aVL, negative T waves in precordial leads V4-V6, presence of left posterior fascicular block, presence of pathologic Q waves, and poor R-wave progression in right precordial leads) proved to be statistically associated with the finding of NLVS; these were grouped together in a score. A score ≥2 was proved to be the optimal cut-off point, identifying NLVS athletes in 92% of cases and showing the best accuracy (86% sensitivity and 100% specificity, respectively). However, a cut-off ≥1 correctly identified all patients with NLVS (absence of false negatives). CONCLUSION: In athletes with RBBB morphology non-sustained VAs, specific ECG abnormalities at 12-lead ECG can help in detecting subjects with NLVS at CMR.


In athletes with right bundle branch block (RBBB) morphology non-sustained ventricular arrhythmias (VAs), the presence of a non-ischaemic left ventricular scar (NLVS) may be highly suspected if one or more of the following electrocardiogram (ECG) characteristics are present at the 12-lead resting ECG: low QRS voltages in limb leads, negative T waves in inferior leads, negative T waves in limb leads I­aVL, negative T waves in precordial leads V4­V6, presence of left posterior fascicular block, presence of pathologic Q waves, and poor R-wave progression in right precordial leads. This score should be externally validated in a larger population of athletes with VAs. In athletes with RBBB morphology non-sustained Vas, attention should be placed on the 12-lead resting ECG to suspect the presence of an NLVS. In athletes with RBBB VAs and the presence of one or more of the identified ECG characteristics, a cardiac magnetic resonance with late gadolinium enhancement is useful to rule out an NLVS.


Asunto(s)
Bloqueo de Rama , Complejos Prematuros Ventriculares , Masculino , Humanos , Adulto , Femenino , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/etiología , Cicatriz/patología , Medios de Contraste , Estudios Transversales , Gadolinio , Electrocardiografía
14.
Int J Cardiol ; 410: 132230, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38852859

RESUMEN

Transthoracic echocardiography (TTE) is routinely required during pre-participation screening in the presence of symptoms, family history of sudden cardiac death or cardiomyopathies <40-year-old, murmurs, abnormal ECG findings or in the follow-up of athletes with a history of cardiovascular disease (CVD). TTE is a cost-effective first-line imaging modality to evaluate the cardiac remodeling due to long-term, intense training, previously known as the athlete's heart, and to rule out the presence of conditions at risk of sudden cardiac death, including cardiomyopathies, coronary artery anomalies, congenital, aortic and heart valve diseases. Moreover, TTE is useful for distinguishing physiological cardiac adaptations during intense exercise from pathological behavior due to an underlying CVD. In this expert opinion statement endorsed by the Italian Society of Sports Cardiology, we discussed common clinical scenarios where a TTE is required and conditions falling in the grey zone between the athlete's heart and underlying cardiomyopathies or other CVD. In addition, we propose a minimum dataset that should be included in the report for the most common indications of TTE in sports cardiology clinical practice.


Asunto(s)
Cardiología , Ecocardiografía , Sociedades Médicas , Medicina Deportiva , Humanos , Ecocardiografía/métodos , Ecocardiografía/normas , Medicina Deportiva/métodos , Medicina Deportiva/normas , Italia , Sociedades Médicas/normas , Cardiología/normas , Cardiología/métodos , Muerte Súbita Cardíaca/prevención & control , Atletas , Testimonio de Experto/métodos , Testimonio de Experto/normas , Deportes/fisiología , Enfermedades Cardiovasculares/diagnóstico por imagen
15.
Heart Rhythm ; 21(5): 555-561, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38242222

RESUMEN

BACKGROUND: There are limited real-world data on the extended prognosis of patients with drug-induced type 1 Brugada electrocardiogram (ECG). OBJECTIVE: We assessed the clinical outcomes and predictors of life-threatening arrhythmias in patients with drug-induced type 1 Brugada ECG. METHODS: This multicenter retrospective study, conducted at 21 Italian and Swiss hospitals from July 1997 to May 2021, included consecutive patients with drug-induced type 1 ECG. The primary outcome, a composite of appropriate ICD therapies and sudden cardiac death, was assessed along with the clinical predictors of these events. RESULTS: A total of 606 patients (mean age 49.7 ± 14.7 years; 423 [69.8%] men) were followed for a median of 60.3 months (interquartile range 23.0-122.4 months). Nineteen patients (3.1%) experienced life-threatening arrhythmias, with a median annual event rate of 0.5% over 5 years and 0.25% over 10 years. The SCN5A mutation was the only predictor of the primary outcome (hazard ratio 4.54; P = .002), whereas a trend was observed for unexplained syncope (hazard ratio 3.85; P = .05). In patients who were asymptomatic at presentation, the median annual rate of life-threatening arrhythmias is 0.24% over 5 years and increases to 1.2% if they have inducible ventricular fibrillation during programmed ventricular stimulation. CONCLUSION: In patients with drug-induced type 1 Brugada ECG, the annual risk of life-threatening arrhythmias is low, with the SCN5A mutation as the only independent predictor. Unexplained syncope correlated with worse clinical outcomes. Ventricular fibrillation inducibility at programmed ventricular stimulation significantly increases the median annual rate of life-threatening arrhythmias from 0.24% to 1.2% over 5 years.


Asunto(s)
Síndrome de Brugada , Electrocardiografía , Sistema de Registros , Humanos , Masculino , Síndrome de Brugada/fisiopatología , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/epidemiología , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Pronóstico , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Italia/epidemiología , Estudios de Seguimiento , Desfibriladores Implantables , Suiza/epidemiología , Factores de Tiempo , Tasa de Supervivencia/tendencias , Adulto
16.
Clin Cardiol ; 46(9): 1021-1027, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37246477

RESUMEN

Ischemic heart disease (IHD) is one of the leading causes of death and morbidity in the world. The role of primary prevention is particularly relevant since IHD can be for a long time asymptomatic until the occurrence of a condition that could lead to plaque instabilization or increased oxygen demand. Secondary prevention is also essential to improve patients' prognosis and quality of life. The aim of this review is to provide a detailed and updated description of the role of sport and physical activity both in primary prevention and secondary prevention. In primary prevention, sport and physical activity are effective through the control of the main cardiovascular risk factors, such as hypertension and dyslipidemia. In secondary prevention, sport and physical activity can lead to a reduction in subsequent coronary events. Every effort must be made to encourage the performance of physical and sports activity both in asymptomatic subjects at risk and those with a history of IHD.


Asunto(s)
Isquemia Miocárdica , Deportes , Humanos , Prevención Secundaria , Calidad de Vida , Isquemia Miocárdica/prevención & control , Isquemia Miocárdica/epidemiología , Ejercicio Físico , Factores de Riesgo , Prevención Primaria
17.
Clin Cardiol ; 46(9): 1028-1037, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37349944

RESUMEN

BACKGROUND: Athletes represent a mainly healthy population, which however could be considered at risk of major arrhythmic events, especially in case of undiagnosed cardiomyopathies. For this reason, the periodical sports medicine examination and the electrocardiography are essential tools in the cardiovascular screening, even though they do not always succeed in identifying rhythm disturbances, particularly when asymptomatic or rarely symptomatic. HYPOTHESIS: Prolonged cardiac monitoring often enables clinicians to stratify the arrhythmic risk and reach the diagnosis. The technological progress of the last decades has produced an always-increasing number of heart rhythm monitoring devices, starting from the 24-hour electrocardiogram Holter monitoring and ending with the wide world of wearable devices. METHODS: In the literature, the extreme utility of this equipment in the patients affected by cardiovascular diseases and in the general population is well established. On the contrary, athletes-based randomized trials or large-scale epidemiological studies targeting the frequency of cardiac symptoms and the use of cardiac monitoring are missing, while an ever-growing number of case series and small observational studies are flourishing in recent years. RESULTS: The present review showcases the available electrocardiographic monitoring options, principally in the medical setting, listing their characteristics, their indications, their supporting evidence, and their general pros and cons. CONCLUSIONS: The ultimate goal of this review is guiding physicians through the wide variety of heart rhythm monitoring options in the specific subfield of sports cardiology, when an arrhythmia is suspected in an athlete, to tailor the diagnostic process and favor the best diagnostic accuracy.

18.
Ann Med Surg (Lond) ; 85(5): 2151-2154, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37228910

RESUMEN

The association of Standford type A acute aortic dissection with situs inversus totalis (SIT) is extremely rare and only a few cases are reported in the literature to date. Due to the particular rarity, this unusual condition, if not diagnosed quickly and correctly, can generate both clinical and surgical difficulties. Case presentation: We describe the case of a male Caucasian patient with SIT and aortic dissection type A, who occurred to our Emergency Department with a severe clinical condition of shock. Using the fast diagnostic approach with chest X-Ray and echocardiography followed by computed tomography investigation, a Standford type A acute aortic dissection and the presence of SIT were detected. The patient was subjected to surgical treatment with optimal results in a short time. Clinical discussion and conclusion: The event of aortic dissection is an extremely serious condition and the simultaneous presence of a critical clinical presentation with an unusual congenital anomaly could condition a correct and rapid diagnostic process. Only an accurate diagnostic investigation can give a quick diagnosis and useful elements for a correct therapeutic approach.

19.
J Clin Med ; 12(20)2023 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-37892812

RESUMEN

The subcutaneous implantable cardioverter-defibrillator (S-ICD) is a new technology for the management of ICD patients. But what is the patients' perspective? Previous studies on the transvenous ICD (TV-ICD) showed that device implantation is related not only to anxiety and depression because of the fear of ICD shocks, but also to many biopsychosocial factors like body image changes, perceived reduction of socialization and limitation in professional and sports activities. Anxiety and distress are more evident in younger women because of aesthetic reasons. The scar size and the position of the S-ICD can help these patients and positively influence their social relationships. Moreover, the position of the S-ICD reduces possible complications from catheters due to stress injury and can improve patients' professional life by avoiding some work activity limitations. An S-ICD can be also a good option for athletes in avoiding subclavian crash and reducing inappropriate shocks. However, some questions remain unsolved because an S-ICD is not suitable for patients with indications for pacing, cardiac resynchronization therapy or anti-tachycardia pacing. In conclusion, the use of an S-ICD can assist physicians in reducing the negative impact of implantation on the well-being of some groups of patients by helping them to avoid depression and anxiety as well as improving their noncompliance with their medical treatment.

20.
Int J Cardiol ; 391: 131220, 2023 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-37517780

RESUMEN

Premature ventricular beats (PVBs) are recorded in a sizeable proportion of athletes during pre-participation screening, especially if the evaluation includes both resting and exercise ECG. While in the majority of cases no underlying heart disease is present, in others PVBs may be the sign of a condition at risk of sudden cardiac death, including cardiomyopathies, congenital, coronary artery, heart valves and ion channels diseases. In this expert opinion document of the Italian Society of Sports Cardiology, we propose a multiparametric interpretation approach to PVBs in athletes and a stepwise diagnostic algorithm. The clinical work-up should include the assessment of the probable site of origin based on the ECG pattern of the ectopic QRS and of the arrhythmia behavior (including the number of different PVB morphologies, complexity, response to exercise and reproducibility), as well as first-line tests such as echocardiography. Based on this initial evaluation, most athletes can be reassured of the benign nature of PVBs and cleared for competition under periodical follow-up. However, when the clinical suspicion is high, further investigations with non-invasive (e.g. cardiac magnetic resonance, cardiac computed tomography, genetic testing) and, in very selected cases, invasive (e.g. endocardial voltage mapping and endomyocardial biopsy) tests should be carried out to rule out a high-risk condition. Importantly, such advanced tests should be performed in centers with a consolidated experience not only in the technique, but also in evaluation of athletes.


Asunto(s)
Cardiología , Complejos Prematuros Ventriculares , Humanos , Complejos Prematuros Ventriculares/diagnóstico , Electrocardiografía/métodos , Testimonio de Experto , Reproducibilidad de los Resultados , Atletas , Muerte Súbita Cardíaca/prevención & control , Italia/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA