Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Small ; : e2404223, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39082408

RESUMEN

This study demonstrates the developments of self-assembled optical metasurfaces to overcome inherent limitations in polarization density (P) and high refractive indices (n) within naturally occurring materials. The Maxwellian macroscopic description establishes a link between P and n, revealing a static limit in natural materials, restricting n to ≈4.0 at optical frequencies. Previously, it is accepted that self-assembly enables the creation of nanogaps between metallic nanoparticles (NPs), boosting capacitive enhancement of P and resultant exceptionally high n at optical frequencies. The work focuses on assembling gold (Au) NPs into a closely packed monolayer by rationally designing the polymeric ligand to balance attractive and repulsive forces, in that polymeric brush-mediated self-assembly of the close-packed Au NP monolayer is robustly achieved over a large-area. The resulting monolayer of Au nanospheres (NSs), nanooctahedras (NOs), and nanocubes (NCs) exhibits high macroscopic integrity and crystallinity, sufficiently enough for pushing n to record-high regimes. The systematic comparisons between each differently shaped Au NP monolayers elucidate the significance of capacitive coupling in achieving an unnaturally high n. The achieved n of 10.12 at optical frequencies stands as a benchmark, highlighting the potential of polyhedral Au NPs in advancing optical metasurfaces.

2.
J Sex Med ; 21(5): 500-504, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38481017

RESUMEN

BACKGROUND: Variations in climate have been associated with a greater risk of surgical site infections, urinary tract infections, and changes in the skin microbiome; however, limited data exist on the impact of climate on inflatable penile prosthesis (IPP) infections. AIM: We sought to evaluate the impact of climate on the risk of IPP infections in a large international, multicenter cohort. METHODS: We performed a multi-institutional, retrospective study of patients undergoing IPP surgery. We then evaluated whether the month or season, during which surgery was performed, affected device infections. Implant infections were defined as infections requiring device explantation. A univariate logistic regression analysis was undertaken. OUTCOMES: Our primary outcome was implant infection. RESULTS: A total of 5289 patients with a mean age of 62.2 ± 10.8 years received IPP placement. There was a fairly even distribution of implants performed in each season. A total of 103 (1.9%) infections were recorded. There were 32 (31.1%) IPP infections in patients who underwent surgery in the summer, followed by 28 (27.2%) in the winter, 26 (25.2%) in the spring, and 17 (16.5%) in the fall. No statistically significant differences were recorded in terms of season (P = .19) and month (P = .29). The mean daily temperature (P = .43), dew point (P = .43), and humidity (P = .92) at the time of IPP placement was not associated with infection. CLINICAL IMPLICATIONS: These findings provide reassurance to prosthetic urologists that infection reduction strategies do not need to be tailored to local climate. STRENGTHS AND LIMITATIONS: Climate data were not directly recorded for each hospital, but rather based on the monthly averages in the city where the surgery was performed. CONCLUSION: The climate at time of IPP placement and time of year of surgery is not associated with IPP infection risk.


Asunto(s)
Prótesis de Pene , Infecciones Relacionadas con Prótesis , Humanos , Masculino , Persona de Mediana Edad , Prótesis de Pene/efectos adversos , Estudios Retrospectivos , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Anciano , Estaciones del Año , Temperatura , Implantación de Pene/efectos adversos , Clima , Factores de Riesgo
3.
Nano Lett ; 23(4): 1546-1554, 2023 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-36757958

RESUMEN

For the colloidal nanophotonic structures, a transmission electron microscope (TEM) grid has been widely used as a substrate of dark-field microscopy because a nanometer-scale feature can be effectively determined by TEM imaging following dark-field microscopic studies. However, an optically lossy carbon layer has been implemented in conventional TEM grids. A broadband scattering from the edges of the TEM grid further restricted an accessible signal-to-noise ratio. Herein, we demonstrate that the freely suspended, ultrathin, and wide-scale transparent nanomembrane can address such challenges. We developed a 1 mm by 600 µm scale and 20 nm thick poly(vinyl formal) nanomembrane, whose area is around 180 times wider than a conventional TEM grid, so that the possible broadband scattering at the edges of the grid was effectively excluded. Also, such nanomembranes can be formed without the assistance of carbon support; allowing us to achieve the highest signal-to-background ratio of scattering among other substrates.

4.
J Urol ; 210(4): 678-687, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37490615

RESUMEN

PURPOSE: Glans vascular compromise had previously been considered a rare but devastating complication of the subcoronal incision for inflatable penile prosthesis surgery. Here, we describe the largest series of subcoronal implants to date to assess contemporary complication rates. MATERIALS AND METHODS: A retrospective review of subcoronal prosthesis placements by a single surgeon from Seoul, South Korea, was performed. Patients were randomly assigned either Coloplast Titan or AMS 700 device per institutional practice. RESULTS: A total of 898 patients who underwent subcoronal implants from May 2015 to March 2022 were analyzed. Median follow-up was 41 months (IQR 40). Preoperative patient comorbidities included diabetes (36.6%) and Peyronie's disease (4%). The most common complication was transient distal penile edema (74.7%). Transient incisional paresthesia (20.6%) was more common in patients with diabetes (31.9% vs 13.9%, P < .01). Five cases (0.5%) of distal penile skin necrosis were reported in patients who had previously been circumcised. Of these, 3 were managed successfully with wet-to-dry dressing, 1 required skin grafting, and 1 required device explant. Device infection without incisional compromise occurred in 2 cases (0.2%). There were no instances of glans necrosis or ischemia observed in this cohort. Of the first-time implants (817, 90.9%), most (62.3%) were successfully completed under local anesthetic alone, with the remainder of surgeries completed with the addition of adjunctive conscious sedation. CONCLUSIONS: Subcoronal incision for first-time or revision penile implant surgery is not a risk factor for glans ischemia or necrosis and can be safely completed under local anesthetic with or without conscious sedation.


Asunto(s)
Diabetes Mellitus , Disfunción Eréctil , Enfermedades del Pene , Implantación de Pene , Induración Peniana , Prótesis de Pene , Masculino , Humanos , Prótesis de Pene/efectos adversos , Implantación de Pene/efectos adversos , Anestésicos Locales , Pene/cirugía , Induración Peniana/complicaciones , Enfermedades del Pene/etiología , Enfermedades del Pene/cirugía , Necrosis/etiología , Necrosis/cirugía , Satisfacción del Paciente , Disfunción Eréctil/etiología
5.
J Urol ; 209(2): 399-409, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36383789

RESUMEN

PURPOSE: Our aim was to determine if the AUA-recommended prophylaxis (vancomycin + gentamicin alone) for primary inflatable penile prosthesis surgery is associated with a higher infection risk than nonstandard regimens. MATERIALS AND METHODS: We performed a multicenter, retrospective study of patients undergoing primary inflatable penile prosthesis surgery. Patients were divided into those receiving vancomycin + gentamicin alone and those receiving any other regimen. A Cox proportional-hazards model was constructed adjusted for major predictors. A subgroup analysis to identify the appropriate dosage of gentamicin was also performed. RESULTS: A total of 4,161 patients underwent primary inflatable penile prosthesis placement (2,411 received vancomycin + gentamicin alone and 1,750 received other regimens). The infection rate was similar between groups, 1% vs 1.2% for standard vs nonstandard prophylaxis. In the multivariable analysis, vancomycin + gentamicin (HR: 2.7, 95% CI: 1.4 to 5.4, P = .004) and diabetes (HR: 1.9, 95% CI: 1.03 to 3.4, P = .04) were significantly associated with a higher risk of infection. Antifungals (HR: 0.08, 95% CI: 0.03 to 0.19, P < .001) were associated with lower risk of infection. There was no statistically significant difference in infection rate between weight-based gentamicin compared to 80 mg gentamicin (HR: 2.9, 95% CI: 0.83 to 10, P = .1). CONCLUSIONS: Vancomycin + gentamicin alone for antibiotic prophylaxis for primary inflatable penile prosthesis surgery is associated with a higher infection risk than nonstandard antibiotic regimens while antifungal use is associated with lower infection risk. A critical review of the recommended antimicrobial prophylactic regimens is needed. Prospective research is needed to further elucidate best practices in inflatable penile prosthesis antimicrobial prophylaxis.


Asunto(s)
Disfunción Eréctil , Implantación de Pene , Prótesis de Pene , Masculino , Humanos , Profilaxis Antibiótica , Vancomicina/uso terapéutico , Estudios Retrospectivos , Estudios Prospectivos , Complicaciones Posoperatorias/cirugía , Prótesis de Pene/efectos adversos , Gentamicinas/uso terapéutico , Disfunción Eréctil/cirugía , Estudios Multicéntricos como Asunto
6.
Int J Mol Sci ; 24(3)2023 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-36768506

RESUMEN

Post-translational modifications of chromatin structure by histone acetyltransferase (HATs) play a pivotal role in the regulation of gene expression and diverse biological processes. However, the function of GNAT family HATs, especially Elp3, in the opportunistic human pathogenic fungus Aspergillus fumigatus is largely unknown. To investigate the roles of the GNAT family HATs Elp3 and GcnE in the A. fumigatus, we have generated and characterized individual null Δelp3 and ΔgcnE mutants. The radial growth of fungal colonies was significantly decreased by the loss of elp3 or gcnE, and the number of asexual spores (conidia) in the ΔgcnE mutant was significantly reduced. Moreover, the mRNA levels of the key asexual development regulators were also significantly low in the ΔgcnE mutant compared to wild type (WT). Whereas both the Δelp3 and ΔgcnE mutants were markedly impaired in the formation of adherent biofilms, the ΔgcnE mutant showed a complete loss of surface structure and of intercellular matrix. The ΔgcnE mutant responded differently to oxidative stressors and showed significant susceptibility to triazole antifungal agents. Furthermore, Elp3 and GcnE function oppositely in the production of secondary metabolites, and the ΔgcnE mutant showed attenuated virulence. In conclusion, Elp3 and GcnE are associated with diverse biological processes and can be potential targets for controlling the pathogenic fungus.


Asunto(s)
Aspergillus fumigatus , Proteínas Fúngicas , Humanos , Aspergillus fumigatus/metabolismo , Proteínas Fúngicas/genética , Proteínas Fúngicas/metabolismo , Histona Acetiltransferasas/genética , Histona Acetiltransferasas/metabolismo , Virulencia/genética , Esporas Fúngicas , Regulación Fúngica de la Expresión Génica
7.
Small ; 18(48): e2205001, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36310131

RESUMEN

The parallelization of multiple microfluidic droplet junctions has been successfully achieved so that the production throughput of the uniform microemulsions/particles has witnessed considerable progress. However, these advancements have been observed only in the case of a low viscous fluid (viscosity of 10-2 -10-3 Pa s). This study designs and fabricates a microfluidic device, enabling a uniform micro-emulsification of an ultraviscous fluid (viscosity of 3.5 Pa s) with a throughput of ≈330 000 droplets per hour. Multiple T-junctions of a dispersed oil phase, split from a single inlet, are connected into the single post-crossflow channel of a continuous water phase. In the proposed device, the continuous water phase undergoes a series circuit, wherein the resistances are continuously accumulated. The independent corrugations of the dispersed oil phase channel, under the theoretical guidance, compromise such increased resistances; the ratio of water to oil flow rates at each junction becomes consistent across T-junctions. Owing to the design being based on a fully 2D interconnection, single-step soft lithography is sufficient for developing the full device. This easy-to-craft architecture contrasts with the previous approach, wherein complicated 3D interconnections of the multiple junctions are involved, thereby facilitating the rapid uptake of high throughput droplet microfluidics for experts and newcomers alike.


Asunto(s)
Técnicas Analíticas Microfluídicas , Microfluídica , Dispositivos Laboratorio en un Chip , Emulsiones , Agua
8.
J Interv Cardiol ; 2021: 6698582, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34366721

RESUMEN

INTRODUCTION: Biolimus-eluting stents (BES) are known to be superior to bare-metal stents. This study aims to evaluate the safety and efficacy of BES compared to other drug-eluting stents (DES) based on big data from the Korea Acute Myocardial Infarction Registry (KAMIR). METHODS: The study analyzed a total of 9,759 acute myocardial infarction (AMI) patients who underwent percutaneous coronary intervention (PCI) with DES. Total death, cardiac death, recurrent MI, revascularization, stent thrombosis, target lesion failure (TLF, composite of cardiac death, recurrent myocardial infarction (MI), and target lesion revascularization), and major adverse cardiac events (MACE, composite of total death, recurrent MI, and revascularization) were analyzed in patients with AMI up to three years. Study populations were divided into BES (n = 2,020), everolimus-eluting stents (EES, n = 5,293), and zotarolimus-eluting stents (ZES, n = 2,446) groups. RESULTS: To adjust baseline potential confounders, an inverse probability weighting (IPTW) analysis was performed. After IPTW, at three years, total death (7.2%, 8.6%, and 9.5%, P < 0.001), cardiac death (4.1%, 5.3%, and 6.6%, P < 0.001), recurrent MI (1.6%, 2.6%, and 3.2%, P < 0.001), TLF (6.5%, 8.1%, and 9.1%, P < 0.001), and MACE (15.8%, 17.5%, and 18.2%, P < 0.001) were lowest in the BES group compared with the other DES groups in AMI patients. During the 3-year clinical follow-up, the BES group showed better outcomes of MACE (hazard ratio (HR), 0.773; 95% confidence interval (CI), 0.676-0.884; P < 0.001), TLF (HR, 0.659; 95% CI, 0.538-0.808; P < 0.001), total death (HR, 0.687; 95% CI, 0.566-0.835; P < 0.001), and cardiac death (HR,0.593; 95% CI, 0.462-0.541; P < 0.001) than the EES groups. CONCLUSIONS: In this study, BES was superior to EES or ZES in reducing total death, cardiac death, TLF, and MACE in AMI patients.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Antagonistas de Receptores de Angiotensina , Inhibidores de la Enzima Convertidora de Angiotensina , Stents Liberadores de Fármacos/efectos adversos , Humanos , Masculino , Infarto del Miocardio/epidemiología , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Sistema de Registros , República de Corea/epidemiología , Stents , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
9.
J Urol ; 204(5): 969-975, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32519913

RESUMEN

PURPOSE: American Urological Association (AUA) antibiotic prophylaxis recommendations may be insufficient for covering organisms commonly found in penile prosthesis infections. In this study we assess the difference between AUA recommended antibiotic prophylaxis and nonstandard prophylaxis in preventing device infections in penile prosthesis surgery performed in diabetic patients. MATERIALS AND METHODS: A multicenter, retrospective cohort study of diabetic patients undergoing primary penile prosthesis surgery was performed between April 2003 and August 2018. Eighteen institutions from the United States, Europe and Korea contributed. The association between antibiotic prophylaxis type and postoperative penile prosthesis infections, device explantations and revision surgeries was assessed. RESULTS: Standard AUA antibiotic prophylaxis was followed in 48.6% (391) of cases while nonstandard prophylaxis was used in 51.4% (413). Common nonstandard antibiotic prophylaxis included vancomycin-gentamycin-fluoroquinolone, clindamycin-fluoroquinolone, and vancomycin-fluoroquinolone among other combinations. Patients who received AUA prophylaxis had significantly more postoperative device infections (5.6% vs 1.9%, p <0.01) and explantations (8.3% vs 2.0%, p <0.001) compared to those who received nonstandard prophylaxis. Patients who received AUA prophylaxis had significantly higher odds of a postoperative device infection (OR 2.8, 95% CI 1.1-7.3) and explantation (OR 3.6, 95% CI 1.4-9.1) compared to those who received nonstandard prophylaxis. CONCLUSIONS: Diabetic men with erectile dysfunction who received standard AUA prophylaxis for penile prosthesis surgery had significantly greater odds of experiencing a postoperative device infection and device explantation compared to patients who received nonstandard prophylaxis. Our study provides a strong rationale for a prospective investigation to establish the most appropriate prophylaxis strategy in penile prosthesis surgery.


Asunto(s)
Profilaxis Antibiótica/normas , Diabetes Mellitus/inmunología , Disfunción Eréctil/cirugía , Prótesis de Pene/efectos adversos , Guías de Práctica Clínica como Asunto , Implantación de Prótesis/efectos adversos , Infecciones Relacionadas con Prótesis/epidemiología , Anciano , Antibacterianos/uso terapéutico , Profilaxis Antibiótica/métodos , Profilaxis Antibiótica/estadística & datos numéricos , Quimioterapia Combinada/métodos , Quimioterapia Combinada/normas , Quimioterapia Combinada/estadística & datos numéricos , Europa (Continente)/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Implantación de Prótesis/instrumentación , Infecciones Relacionadas con Prótesis/inmunología , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/prevención & control , Reoperación/estadística & datos numéricos , República de Corea/epidemiología , Estudios Retrospectivos , Sociedades Médicas/normas , Resultado del Tratamiento , Estados Unidos/epidemiología , Urología/normas
10.
J Sex Med ; 17(10): 2077-2083, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32807707

RESUMEN

BACKGROUND: Modern-day penile prostheses use infection retardant coating to decrease rates of postoperative infection, subsequently reducing explantation and revision rates as well. The Coloplast Titan models are dipped into antimicrobial solutions right before implantation, and the components used for dipping can be tailored toward the patient. AIM: To compare infection, explantation, and revision rates among different dipping solutions used before implantation for patients with diabetes receiving a Coloplast Titan implant. METHODS: We systematically reviewed 932 patients with diabetes receiving a primary penile implant across 18 different centers from the period April 2003 to August 2018. Of those patients, 473 received a Coloplast device, whereas 459 received an AMS device. Data regarding the type of antimicrobial solution used before implantation were recorded for 468 patients receiving a Coloplast Titan, including whether or not they suffered a postoperative infection and if they underwent explantation and/or revision. Outcome rates were compared using Fisher's exact and Pearson's chi-square tests, and logistic regression modeling was performed to account for covariates. OUTCOMES: The main outcome measures of this study were postoperative infection, explantation, and revision rates. RESULTS: Of the total 932 patients reviewed, 33 suffered a postoperative infection. Of 468 patients receiving Coloplast implants, there was a 3.4% infection rate. The most commonly used antibiotic combination before dipping was vancomycin + gentamicin (59.0%). There was a significantly lower rate of postoperative infection, explantation, and revision when vancomycin + gentamicin was used than those associated with the use of all other dipping solutions ([1.4% vs 6.4%; P = .004], [1.1% vs 8.3%; P < .001], and [2.5% vs 12.5; P < .001], respectively). After adjusting for age, body mass index, preoperative blood glucose level, and hemoglobin A1c, the use of other dips was an independent predictor of postoperative infection (odds ratio: 0.191; P = .049). The inclusion of rifampin in the dipping solution trended toward being a significant risk factor for infection (P = .057). Including antifungals in the dipping solution did not affect infection (P = .414), explantation (P = .421), or revision (P = .328) rates. CLINICAL IMPLICATIONS: Vancomycin + gentamicin was the most efficacious combination of antibiotics used for dipping in terms of preventing postoperative infection and subsequent explantation and revision. STRENGTHS AND LIMITATIONS: Data were sampled across multiple institutions providing a large sample that may be more representative of the population of interest. A key limitation of the study was its retrospective nature, which prevented us from controlling certain variables. CONCLUSION: The use of rifampin did not provide the same type of protection, possibly representing a shift in resistance patterns of common bacteria responsible for device infection. Towe M, Huynh LM, Osman MM, et al. Impact of Antimicrobial Dipping Solutions on Postoperative Infection Rates in Patients With Diabetes Undergoing Primary Insertion of a Coloplast Titan Inflatable Penile Prosthesis. J Sex Med 2020;17:2077-2083.


Asunto(s)
Diabetes Mellitus , Implantación de Pene , Prótesis de Pene , Diabetes Mellitus/tratamiento farmacológico , Gentamicinas/uso terapéutico , Humanos , Masculino , Estudios Retrospectivos
11.
J Cardiovasc Pharmacol ; 71(1): 38-45, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29286954

RESUMEN

BACKGROUND: Although ß-blockers are known to increase new-onset diabetes mellitus (DM), previous evidence have been controversial. It has been suggested that newer vasodilatory ß-blockers yield better glycemic control than older nonselective agents. The aim of this study was to evaluate the diabetogenicity of currently used newer ß-blockers based on ß1 receptor selectivity in a series of Asian population. METHODS: We investigated a total of 65,686 hypertensive patients without DM from 2004 to 2014. Patients with hemoglobin (Hb) A1c ≤6.0%, fasting blood glucose ≤110 mg/dL, and no history of diabetes or diabetic treatment were enrolled for analysis. Patients were divided into the ß-blockers group and non-ß-blockers group. Propensity score matching (PSM) analysis using a logistic regression model was performed to adjust for potential confounders. The primary end point was the cumulative incidence of new-onset DM, defined as a fasting blood glucose ≥126 mg/dL or HbA1c ≥6.5%, and major adverse cardiac and cerebral events (MACCE), defined as a composite of total death, nonfatal myocardial infarction, and cerebrovascular accidents. We investigated predictors of new-onset DM and MACCE based on 2 models, including clinical risk factors and co-medications, respectively. RESULTS: Mean follow-up duration was 30.91 ± 23.14 months in the entire group before adjustment. The ß-blockers group had a significantly higher incidence of new-onset DM and MACCE than the non-ß-blockers group. After PSM, analysis of a total of 2284 patients (1142 pairs, C-statistic = 0.752) showed no difference between the 2 groups in new-onset DM or MACCE. In multivariate analysis after PSM, baseline HbA1c, stroke, heart failure, nonselective ß-blockers, and age were independent predictors of new-onset DM. Selective ß1-blockers did not increase new-onset DM after adjustment for other antihypertensive medication and statins. CONCLUSIONS: In the era of newer ß-blockers, selective ß1-blockers were not associated with new-onset DM. More evidence is needed to verify this relationship and the underlying mechanisms.


Asunto(s)
Antagonistas de Receptores Adrenérgicos beta 1/uso terapéutico , Antihipertensivos/uso terapéutico , Presión Sanguínea/efectos de los fármacos , Diabetes Mellitus/epidemiología , Hipertensión/tratamiento farmacológico , Antagonistas de Receptores Adrenérgicos beta 1/efectos adversos , Adulto , Anciano , Antihipertensivos/efectos adversos , Diabetes Mellitus/inducido químicamente , Diabetes Mellitus/diagnóstico , Femenino , Humanos , Hipertensión/diagnóstico , Hipertensión/epidemiología , Hipertensión/fisiopatología , Incidencia , Masculino , Persona de Mediana Edad , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Seúl/epidemiología , Factores de Tiempo , Resultado del Tratamiento
12.
Clin Exp Pharmacol Physiol ; 45(6): 499-506, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29266345

RESUMEN

Recently, meta-analysis studies reported that hyperuricaemia is associated with higher incidence of type 2 diabetes mellitus (T2DM), however, there are limited data on the Asian population. The aim of this observational study is to estimate the long-term impact of hyperuricaemia on the new-onset T2DM and cardiovascular events. This study is based on a single-centre, all-comers, and large retrospective cohort. Subjects that visited from January 2004 to February 2014 were enrolled using the electronic database of Korea University Guro Hospital. A total of 10 505 patients without a history of T2DM were analyzed for uric acid, fasting glucose and haemoglobin (Hb) A1c level. Inclusion criteria included both Hb A1c <5.7% and fasting glucose level <100 mg/dL without T2DM. Hyperuricaemia was defined as a uric acid level ≥7.0 mg/dL in men, and ≥6.5 mg/dL in women. To adjust baseline confounders, a propensity score matching (PSM) analysis was performed. The impact of hyperuricaemia on the new-onset T2DM and cardiovascular events were compared with the non-hyperuricaemia during the 5-year clinical follow-up. After PSM, baseline characteristics of both groups were balanced. In a 5-year follow-up, the hyperuricaemia itself was a strong independent predictor of the incidence of new-onset T2DM (HR, 1.78; 95% CI, 1.12 to 2.8). Hyperuricaemia was a strong independent predictor of new-onset T2DM, which suggests a substantial implication for a correlation between uric acid concentration and insulin resistance (or insulin sensitivity). Also, hyperuricaemia is substantially implicated in cardiovascular risks and the further long-term cardiovascular events in the crude population, but it is not an independent predictor of long-term cardiovascular mortality in the matched population.


Asunto(s)
Pueblo Asiatico/estadística & datos numéricos , Diabetes Mellitus Tipo 2/complicaciones , Hiperuricemia/complicaciones , Anciano , Diabetes Mellitus Tipo 2/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad
13.
Int Heart J ; 58(5): 704-713, 2017 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-28966331

RESUMEN

There is limited long-term comparative clinical outcome data concerning angiography- versus intravascular ultrasound (IVUS)-guided percutaneous coronary intervention (PCI) in non-complex left main coronary artery (LMCA) disease treated with the single stenting technique in the drug-eluting stent (DES) era.The aim of this study was to investigate whether angiography-guided stenting is comparable to IVUS-guided stenting during 3-year clinical follow-up periods in patients with non-complex LM disease treated with the single stenting technique.A total of 196 patients treated with either angiography-guided (n = 74) or IVUS-guided (n = 122) PCI were included. The primary outcome was the occurrence of major adverse cardiac events (MACE) defined as total death, non-fatal myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), and non-target vessel revascularization (Non-TVR). To adjust for any potential confounders, propensity score (PS) adjusted analysis was performed.During 3-year follow-up, the PS adjusted Cox-proportional hazard ratio (HR) was not significantly different between the two groups for total death, cardiac death, and MI. Also, TLR and the combined rates of TVR and non-TVR were not significantly different. Finally, MACE was not significantly different between the two groups (HR: 0.63, 95% Confidence interval (CI): 0.33-1.17; P = 0.149).Angiography-guided PCI for non-complex LMCA diseases treated with the single stenting technique showed comparable results compared with IVUS-guided PCI in reducing clinical events during 3-year clinical follow-up in the DES era. Although IVUS guided PCI is the ideal strategy, angiography-guided PCI can be an option for LMCA PCI in some selected cases.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria , Vasos Coronarios/diagnóstico por imagen , Efectos Adversos a Largo Plazo , Intervención Coronaria Percutánea , Cirugía Asistida por Computador/métodos , Ultrasonografía Intervencional/métodos , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos/estadística & datos numéricos , Femenino , Estudios de Seguimiento , Humanos , Efectos Adversos a Largo Plazo/diagnóstico , Efectos Adversos a Largo Plazo/epidemiología , Efectos Adversos a Largo Plazo/etiología , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , República de Corea/epidemiología , Índice de Severidad de la Enfermedad , Análisis de Supervivencia
15.
Korean J Parasitol ; 52(6): 667-72, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25548419

RESUMEN

While imported falciparum malaria has been increasingly reported in recent years in Korea, clinicians have difficulties in making a clinical diagnosis as well as in having accessibility to effective anti-malarial agents. Here we describe an unusual case of imported falciparum malaria with severe hemolytic anemia lasting over 2 weeks, clinically mimicking a coinfection with babesiosis. A 48-year old Korean man was diagnosed with severe falciparum malaria in France after traveling to the Republic of Benin, West Africa. He received a 1-day course of intravenous artesunate and a 7-day course of Malarone (atovaquone/proguanil) with supportive hemodialysis. Coming back to Korea 5 days after discharge, he was readmitted due to recurrent fever, and further treated with Malarone for 3 days. Both the peripheral blood smears and PCR test were positive for Plasmodium falciparum. However, he had prolonged severe hemolytic anemia (Hb 5.6 g/dl). Therefore, 10 days after the hospitalization, Babesia was considered to be potentially coinfected. A 7-day course of Malarone and azithromycin was empirically started. He became afebrile within 3 days of this babesiosis treatment, and hemolytic anemia profiles began to improve at the completion of the treatment. He has remained stable since his discharge. Unexpectedly, the PCR assays failed to detect DNA of Babesia spp. from blood. In addition, during the retrospective review of the case, the artesunate-induced delayed hemolytic anemia was considered as an alternative cause of the unexplained hemolytic anemia.


Asunto(s)
Anemia Hemolítica/etiología , Anemia Hemolítica/patología , Babesiosis/diagnóstico , Babesiosis/patología , Malaria Falciparum/diagnóstico , Malaria Falciparum/patología , Plasmodium falciparum/aislamiento & purificación , Anemia Hemolítica/inducido químicamente , Antibacterianos/uso terapéutico , Antimaláricos/uso terapéutico , Artemisininas/efectos adversos , Artemisininas/uso terapéutico , Artesunato , Atovacuona/uso terapéutico , Azitromicina/uso terapéutico , Babesiosis/complicaciones , Babesiosis/tratamiento farmacológico , Benin , Sangre/parasitología , Coinfección/diagnóstico , Coinfección/patología , Combinación de Medicamentos , Francia , Humanos , Corea (Geográfico) , Malaria Falciparum/complicaciones , Malaria Falciparum/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Proguanil/uso terapéutico , Viaje , Resultado del Tratamiento
16.
Adv Mater ; 36(23): e2312748, 2024 Jun.
Artículo en Catalán | MEDLINE | ID: mdl-38450572

RESUMEN

A general guiding principle for colloidal crystallization is to tame the attractive enthalpy such that it slightly overwhelms the repulsive interaction. As-synthesized colloids are generally designed to retain a strong repulsive potential for the high stability of suspensions, encoding appropriate attractive potentials into colloids has been key to their crystallization. Despite the myriad of interparticle attractions for colloidal crystallization, the van der Waals (vdW) force remains unexplored. Here, it is shown that the implementation of gold cores into silica colloids and the resulting vdW force can reconfigure the pair potential well depth to the optimal range between -1 and -4 kBT at tens of nanometer-scale colloidal distances. As such, colloidal crystals with a distinct liquid gap can be formed, which is evidenced by photonic bandgap-based diffractive colorization.

17.
Sci Rep ; 14(1): 542, 2024 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-38177401

RESUMEN

In this study, the deoxidation process for off-grade titanium (Ti) sponge using magnesium (Mg) metal with a wire mesh strainer type of crucible was developed. Ti hydride (TiH2) feedstock, which was prepared by hydrogenating off-grade Ti sponge, was deoxidized using Mg in a molten magnesium chloride-potassium chloride salt at 933 K under an argon and 20% hydrogen (H2) mixed gas atmosphere. After deoxidation, the residual Mg-containing salt was separated in situ from the crucible to investigate the feasibility of minimizing salt loss during the leaching and production of pure TiH2. The results showed that the presence of residual Mg-containing salt inside the crucible strongly influenced whether a mixture of Ti and TiH2 or pure TiH2 was produced. When the salt was not sufficiently separated, a mixture of Ti and TiH2 was obtained and its oxygen (O) concentration was 0.121 mass% under certain conditions. Meanwhile, pure TiH2 was obtained by increasing the H2 gas flow rate during deoxidation. Therefore, these results demonstrate that the decrease of O concentration to below 0.180 mass% and the minimal loss of the salt are feasible.

18.
Urology ; 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38972393

RESUMEN

OBJECTIVE: To evaluate predictors of implant length for men undergoing primary IPP placement. METHODS: A multicenter, retrospective cohort study was performed for men undergoing primary IPP placement at 16 high-volume surgical centers. Patient demographics, comorbidities, operative approach, and implanted cylinder and rear-tip extender length were recorded. Associations between potential preoperative and intraoperative predictors of total device length were tested using non-parametric correlation and Kruskal-Wallis tests, followed by multiple regression. RESULTS: Of 3951 men undergoing primary IPP placement from July 2016 to July 2021, the median implant length was 20 cm (IQR: 19-22). Shorter implant length was associated with increasing age in years (ß = -0.01, P = .009), Asian ethnicity (ß = -2.34, P = .008), history of radical prostatectomy (ß = -0.35, P = .001), and use of an infrapubic surgical approach (ß = -1.02, P <.001). Black or African American ethnicity was associated with the implantation of longer devices (ß = 0.35, P <.001). No significant associations were recorded with BMI, history of intracavernosal injections, diabetes mellitus, tobacco use, radiation therapy, Peyronie's disease, priapism, or cavernosal dilation technique. CONCLUSION: The length of an implanted penile prosthesis was found to be associated with preoperative and intraoperative factors including history of radical prostatectomy and operative approach. The knowledge of these associations may assist in the preoperative counseling of patients receiving IPP and help create accurate postoperative expectations.

19.
JMIR Cardio ; 7: e45299, 2023 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-37099368

RESUMEN

BACKGROUND: An accurate quantitative analysis of coronary artery stenotic lesions is essential to make optimal clinical decisions. Recent advances in computer vision and machine learning technology have enabled the automated analysis of coronary angiography. OBJECTIVE: The aim of this paper is to validate the performance of artificial intelligence-based quantitative coronary angiography (AI-QCA) in comparison with that of intravascular ultrasound (IVUS). METHODS: This retrospective study included patients who underwent IVUS-guided coronary intervention at a single tertiary center in Korea. Proximal and distal reference areas, minimal luminal area, percent plaque burden, and lesion length were measured by AI-QCA and human experts using IVUS. First, fully automated QCA analysis was compared with IVUS analysis. Next, we adjusted the proximal and distal margins of AI-QCA to avoid geographic mismatch. Scatter plots, Pearson correlation coefficients, and Bland-Altman were used to analyze the data. RESULTS: A total of 54 significant lesions were analyzed in 47 patients. The proximal and distal reference areas, as well as the minimal luminal area, showed moderate to strong correlation between the 2 modalities (correlation coefficients of 0.57, 0.80, and 0.52, respectively; P<.001). The correlation was weaker for percent area stenosis and lesion length, although statistically significant (correlation coefficients of 0.29 and 0.33, respectively). AI-QCA tended to measure reference vessel areas smaller and lesion lengths shorter than IVUS did. Systemic proportional bias was not observed in Bland-Altman plots. The biggest cause of bias originated from the geographic mismatch of AI-QCA with IVUS. Discrepancies in the proximal or distal lesion margins were observed between the 2 modalities, which were more frequent at the distal margins. After the adjustment of proximal or distal margins, there was a stronger correlation of proximal and distal reference areas between AI-QCA and IVUS (correlation coefficients of 0.70 and 0.83, respectively). CONCLUSIONS: AI-QCA showed a moderate to strong correlation compared with IVUS in analyzing coronary lesions with significant stenosis. The main discrepancy was in the perception of the distal margins by AI-QCA, and the correction of margins improved the correlation coefficients. We believe that this novel tool could provide confidence to treating physicians and help in making optimal clinical decisions.

20.
Int J Impot Res ; 35(6): 564-568, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35941220

RESUMEN

Men with erectile dysfunction (ED) have high patient satisfaction after placement of inflatable penile prostheses (IPP). The impact on satisfaction and quality of life has never been studied in men who have sex with men (MSM). This study sought to assess the satisfaction rates and quality of life of MSM after placement of IPP for ED. This study was a multi-institutional, retrospective study that enrolled adult men who self-identified as MSM and underwent IPP placement. Two questionnaires were administered at one time point post-operatively, the Erectile Dysfunction Inventory of Treatment Satisfaction (EDITS), and the Quality of Life and Sexuality with Penile Prosthesis (QoLSPP) questionnaire. Results of these questionnaires were analyzed with descriptive statistics. Forty-nine MSM were assessed retrospectively with median age of 62 years with average follow-up of 15.2 months. Median EDITS score was 93.2/100 (range, 70.5-100). Median overall QoLSPP score was 72/80 (58-79), with median scores of 22/25 (16-25), 19/20 (13-20), 18/20 (12-20), and 14/15 (9-15), for the functional, personal, relational, and social domains respectively. Overall, MSM report high satisfaction rates and quality of life after IPP placement. A better understanding of the needs and demands of this patient population may lead to improved patient satisfaction and quality of life.


Asunto(s)
Disfunción Eréctil , Implantación de Pene , Prótesis de Pene , Minorías Sexuales y de Género , Masculino , Adulto , Humanos , Persona de Mediana Edad , Disfunción Eréctil/cirugía , Estudios Retrospectivos , Homosexualidad Masculina , Calidad de Vida , Implantación de Pene/métodos , Satisfacción del Paciente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA