Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Shoulder Elbow Surg ; 33(2): 409-416, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37748530

RESUMEN

BACKGROUND: Recently, a new generation of superior clavicle plates was developed featuring the variable-angle locking technology for enhanced screw positioning and a less prominent and optimized plate-to-bone fit design. On the other hand, minifragment plates in dual plating mode have demonstrated promising clinical results. The aim of the current study was to compare the biomechanical competence of single superior plating using the new-generation plate vs. dual plating using low-profile minifragment plates. METHODS: Sixteen paired human cadaveric clavicles were pairwise assigned to 2 groups for instrumentation with either a superior 2.7-mm variable-angle locking compression plate (group 1), or with one 2.5-mm anterior combined with one 2.0-mm superior matrix mandible plate (group 2). An unstable clavicle shaft fracture (AO/OTA 15.2C) was simulated by means of a 5-mm osteotomy gap. Specimens were cyclically tested to failure under craniocaudal cantilever bending, superimposed with bidirectional torsion around the shaft axis, and monitored via motion tracking. RESULTS: Initial construct stiffness was significantly higher in group 2 (9.28 ± 4.40 N/mm) compared to group 1 (3.68 ± 1.08 N/mm), P = .003. The amplitudes of interfragmentary motions in terms of axial and shear displacement, fracture gap opening and torsion, over the course of 12,500 cycles were significantly higher in group 1 compared to group 2, P ≤ .038. Cycles to 2 mm shear displacement were significantly lower in group 1 (22,792 ± 4346) compared to group 2 (27,437 ± 1877), P = .047. CONCLUSION: From a biomechanical perspective, low-profile 2.5/2.0-mm dual plates could be considered as a useful alternative for diaphyseal clavicle fracture fixation, especially in less common unstable fracture configurations.


Asunto(s)
Clavícula , Fracturas Óseas , Humanos , Clavícula/cirugía , Fenómenos Biomecánicos , Fracturas Óseas/cirugía , Fijación Interna de Fracturas/métodos , Tornillos Óseos , Placas Óseas
2.
Int Orthop ; 48(3): 643-649, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38015209

RESUMEN

PURPOSE: The number of seven required throws per knot was previously reported as providing sufficient security against slippage. A novel high-strength suture featuring dynamic tightening may allow for throw number reduction without compromising stability. The aims of this study were to (1) investigate the influence of the throw number and the effect of different ambient conditions on the knot security of two different high-strength sutures, and (2) compare their biomechanical competence. METHODS: Two sutures (FiberWire (FW) and DynaCord (DC)) were considered for preparing alternating surgical knots. The specimens were stratified for exposure to different media during biomechanical testing-namely air (dry), saline solution (wet), and fat (fatty-wet). A monotonic tensile ramp loading to failure was applied in each test run. For each suture and ambient condition, seven specimens with three to seven throws each were tested (n = 7), evaluating their slippage and ultimate force to failure. The minimum number of throws preventing suture unraveling was determined for each suture type and condition. RESULTS: For each suture type and condition, failure occurred via rupture in all specimens for the following minimum number of throws: FW-dry-7, wet-7, fatty-wet-7; DC-dry-6, wet-4, fatty-wet-5. When applying seven throws, FW demonstrated significantly larger slippage (6.5 ± 2.2 mm) versus DC (3.5 ± 0.4 mm) in wet (p = 0.004) but not in dry and fatty-wet conditions (p ≥ 0.313). CONCLUSIONS: The lower number of throws providing knot security of DC versus FW in the more realistic wet and fatty-wet conditions indicates that the novel DC suture may allow to decrease the foreign body volume and save surgical time without compromising the biomechanical competence.


Asunto(s)
Técnicas de Sutura , Suturas , Humanos , Ensayo de Materiales , Resistencia a la Tracción , Rotura , Técnicas de Sutura/efectos adversos
3.
Arch Orthop Trauma Surg ; 144(4): 1865-1873, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38267722

RESUMEN

PURPOSE: Gracilis muscle flaps are useful to cover defects of the hand. However, there are currently no studies describing outcome measurements after covering soft tissue defects using free flaps in the hand. AIM: To analyze mid-term results of gracilis muscle flap coverage for defects on the hand, with regard to functional and esthetic integrity. METHODS: 16 patients aged 44.3 (range 20-70) years were re-examined after a mean follow-up of 23.6 (range 2-77) months. Mean defect size was 124 (range 52-300) cm2 located palmar (n = 9), dorsal (n = 6), or radial (n = 1). All flaps were performed as microvascular muscle flaps, covered by split thickness skin graft. RESULTS: Flaps survived in 15 patients. 6 patients required reoperations. Reasons for revisions were venous anastomosis failure with total flap loss (n = 1) requiring a second gracilis muscle flap; necrosis at the tip of the flap (n = 1) with renewed split thickness skin cover. A surplus of the flap (n = 2) required flap thinning and scar corrections were performed in 2 patients. Mean grip strength was 25% (range 33.3-96.4%) compared to the contralateral side and mean patient-reported satisfaction 1.4 (range 1-3) (1 = excellent; 4 = poor). CONCLUSIONS: Gracilis muscle flaps showed a survival rate of 94%. Patients showed good clinical outcomes with acceptable wrist movements and grip strength as well as high reported satisfaction rates. Compared to fasciocutaneous free flaps, pliability and thinness especially on the palmar aspect of the hand are advantageous. Hence, covering large defects of the hand with a gracilis muscle flap can be a very satisfactory procedure. LEVEL OF EVIDENCE: IV observational.


Asunto(s)
Colgajos Tisulares Libres , Músculo Grácil , Procedimientos de Cirugía Plástica , Traumatismos de los Tejidos Blandos , Humanos , Músculo Grácil/cirugía , Mano/cirugía , Trasplante de Piel , Traumatismos de los Tejidos Blandos/cirugía , Resultado del Tratamiento , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano
4.
Arch Orthop Trauma Surg ; 144(6): 2905-2914, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38693291

RESUMEN

BACKGROUND: Early mobilization after tendon surgery is crucial to avoid commonly observed postoperative soft tissue adhesions. Recently, a new suture was introduced (DYNACORD; DC) with a salt-infused silicone core designed to minimize laxity and preserve consistent tissue approximation in order to avoid gap formation and allow early mobilization. AIMS: To compare the biomechanical competence of DC against a conventional high strength suture (FiberWire; FW) in a human cadaveric tendon transfer model with an early rehabilitation protocol. METHODS: Sixteen tendon transfers (flexor digitorum superficialis (FDS) IV to flexor pollicis longus (FPL)) were performed in 8 pairs human cadaveric forearms using either DC or FW. Markings were set 0.8 cm proximally and 0.7 cm distally to the level of the interweaving zone of the transfer. All specimens underwent repetitive thumb flexion against resistance in 9 intermittent series of 300 cycles each, simulating an aggressive postoperative rehabilitation protocol. After each series, the distance of the proximal marker to the interweaving zone (proximal), the length of the interweaving zone (intermediate) and the distance of the distal marker to the interweaving zone (distal) were measured. RESULTS: Pooled data over all nine series, normalized to the immediate postoperative status, demonstrated no significant differences between FW and DC (p ≥ 0.355) for the proximal and distal markers. However, at the intermediate zone, DC was associated with significant length shortening (p < 0.001) compared to FW without significant length changes (p = 0.351). Load to catastrophic failure demonstrated significant higher forces in FW (p = 0.011). Nevertheless, due to failure mainly proximal or distal of the transfer zone, these loads are not informative. CONCLUSION: From a biomechanical perspective, DC preserved tissue approximation and might be considered as a valid alternative to conventional high-strength sutures in tendon transfer surgery. DC might allow for a shorter interweaving zone and a more aggressive early postoperative rehabilitation program, possibly avoiding commonly observed postoperative soft tissue adhesions and stiffness.


Asunto(s)
Cadáver , Suturas , Transferencia Tendinosa , Humanos , Transferencia Tendinosa/métodos , Fenómenos Biomecánicos , Extremidad Superior/cirugía , Masculino , Técnicas de Sutura , Anciano , Femenino
5.
Arch Orthop Trauma Surg ; 144(4): 1611-1619, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38285222

RESUMEN

PURPOSE: Freehand distal interlocking of intramedullary nails remains a challenging task. Recently, a new training device for digitally enhanced hands-on surgical training (DEHST) was introduced, potentially improving surgical skills needed for distal interlocking. AIM: To evaluate whether training with DEHST enhances the performance of novices (first-year residents without surgical experience in freehand distal nail interlocking). METHODS: Twenty novices were randomly assigned to two groups and performed distal interlocking of a tibia nail in mock operation under operation-room-like conditions. Participants in Group 1 were trained with DEHST (five distal interlocking attempts, 1 h of training), while those in Group 2 did not receive training. Time, number of X-rays shots, hole roundness in the X-rays projection and hit rates were compared between the groups. RESULTS: Time to complete the task [414.7 s (range 290-615)] and X-rays exposure [17.8 µGcm2 (range 9.8-26.4)] were significantly lower in Group 1 compared to Group 2 [623.4 s (range 339-1215), p = 0.041 and 32.6 µGcm2 (range 16.1-55.3), p = 0.003]. Hole projections were significantly rounder in Group 1 [95.0% (range 91.1-98.0) vs. 80.8% (range 70.1-88.9), p < 0.001]. In Group 1, 90% of the participants achieved successful completion of the task in contrast to a 60% success rate in Group 2. This difference was not statistically significant (p = 0.121). CONCLUSIONS: In a mock-operational setting, training with DEHST significantly enhanced the performance of novices without surgical experience in distal interlocking of intramedullary nails and hence carries potential to improve safety and efficacy of this important and demanding surgical task to steepen the learning curve without endangering patients. LEVEL OF EVIDENCE: II.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de la Tibia , Humanos , Clavos Ortopédicos , Radiografía , Tibia , Fracturas de la Tibia/cirugía
6.
Medicina (Kaunas) ; 60(6)2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38929461

RESUMEN

Background and Objectives: Despite the established role of subtalar joint arthrodesis (SJA) for treatment of subtalar osteoarthritis, achieving bone union remains challenging, with up to 46% non-union rates. Adequate compression and stable fixation are crucial for successful outcomes, with internal screw fixation being the gold standard for SJA. The delta configuration, featuring highly divergent screws, offers stability, however, it can result in hardware irritation in 20-30% of patients. Solutions to solve this complication include cannulated compression screw (CCS) countersinking or cannulated compression headless screw (CCHS) application. The aim of this biomechanical study was to investigate the stability of a delta configuration for SJA utilizing either a combination of a posterior CCHS and an anterior CCS or a standard two-CCS combination. Materials and Methods: Twelve paired human cadaveric lower legs were assigned pairwise to two groups for SJA using either two CCSs (Group 1) or one posterior CCHS and one anterior CCS (Group 2). All specimens were tested under progressively increasing cyclic loading to failure, with monitoring of the talocalcaneal movements via motion tracking. Results: Initial stiffness did not differ significantly between the groups, p = 0.949. Talocalcaneal movements in terms of varus-valgus deformation and internal-external rotation were significantly bigger in Group 1 versus Group 2, p ≤ 0.026. Number of cycles until reaching 5° varus-valgus deformation was significantly higher in Group 2 versus Group 1, p = 0.029. Conclusions: A delta-configuration SJA utilizing a posterior CCHS and an anterior CCS is biomechanically superior versus a standard configuration with two CCSs. Clinically, the use of a posterior CCHS could prevent protrusion of the hardware in the heel, while an anterior CCS could facilitate less surgical time and thus less complication rates.


Asunto(s)
Artrodesis , Tornillos Óseos , Cadáver , Articulación Talocalcánea , Humanos , Artrodesis/métodos , Artrodesis/instrumentación , Articulación Talocalcánea/cirugía , Fenómenos Biomecánicos , Masculino , Femenino , Anciano , Osteoartritis/cirugía , Persona de Mediana Edad
7.
BMC Musculoskelet Disord ; 24(1): 279, 2023 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-37041618

RESUMEN

BACKGROUND: The aim of this study was to investigate the biomechanical performance of novel anterior variable-angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. METHODS: Sixteen pairs of human cadaveric knees were used to simulate two-part simple transverse AO/OTA 34-C1 and five-part complex AO/OTA 34-C3 patella fractures. The complex fracture pattern was characterized with a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral and an inferior fragment mimicking comminution around the distal patella pole. Eight pairs with simple fractures were split for fixation via either tension band wiring (TBW) through two parallel cannulated screws or anterior variable-angle locked plating, whereas other eight pairs with complex fractures were split for either TBW through two parallel cannulated screws plus circumferential cerclage wiring, or anterior variable-angle locked plating using a cortical caudo-cranial polar screw. Each specimen was tested over 5000 cycles with a range of motion from 90° flexion to full extension by pulling on the quadriceps tendon. Interfragmentary movements were captured by motion tracking. RESULTS: For both fracture types, the longitudinal and shear articular displacements, measured between the proximal and distal fragments at the central patella aspect between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following anterior variable-angle locked plating versus TBW, p ≤ 0.01. CONCLUSIONS: From a biomechanical perspective, anterior locked plating of both simple and complex patella fractures resulted in less interfragmentary displacement under extended cyclic loading.


Asunto(s)
Fracturas Óseas , Traumatismos de la Rodilla , Fractura de Rótula , Humanos , Fenómenos Biomecánicos , Fracturas Óseas/cirugía , Fijación Interna de Fracturas/métodos , Tornillos Óseos , Traumatismos de la Rodilla/cirugía
8.
Arch Orthop Trauma Surg ; 143(8): 4983-4991, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36821049

RESUMEN

BACKGROUND: Proximal humeral shaft fractures are surgically challenging and plate osteosynthesis with a long straight plate is one operative treatment option in these patients although endangering the radial nerve distally. Helical plates potentially avoid the radial nerve by twisting around the humeral shaft. Aim of the study was to investigate in a human cadaveric model the biomechanical competence of helical plates versus straight lateral plates used for fixation of proximal third comminuted humeral shaft fractures. METHODS: Eight pairs of humeral cadaveric humeri were instrumented using either a long 90°-helical plate (Group1) or a straight long PHILOS plate (Group2). An unstable proximal humeral shaft fracture was simulated by means of a 5 cm osteotomy gap. All specimens were tested under quasi-static loading in axial compression, internal and external rotation, and bending in four directions. Subsequently, progressively increasing cyclic loading in internal rotation until failure was applied and interfragmentary movements were monitored by motion tracking. RESULTS: During static testing flexion/extension deformation in Group1 was significantly higher, however, varus/valgus deformation as well as shear and torsional displacement under torsional load remained statistically indifferent between both groups. During cyclic testing shear and torsional displacements were both significantly higher in Group1 compared to Group 2. However, cycles to catastrophic failure remained statistically indifferent between the groups. CONCLUSIONS: From a biomechanical perspective, although 90°-helical plating is associated with higher initial stability against varus/valgus collapse and comparable endurance under dynamic loading, it demonstrates lower resistance to flexion/extension and internal rotation with bigger shear interfragmentary displacements versus straight lateral plating and, therefore, cannot be considered as its real alternative. Alternative helical plate designs should be investigated in the future.


Asunto(s)
Fracturas del Húmero , Fracturas del Hombro , Humanos , Fenómenos Biomecánicos , Fijación Interna de Fracturas , Placas Óseas , Fracturas del Húmero/cirugía , Húmero , Fracturas del Hombro/cirugía , Cadáver
9.
Medicina (Kaunas) ; 59(1)2023 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-36676737

RESUMEN

Background and Objectives: Combined fractures of the humeral head and shaft (FHS) are rare but frequently involve an intermuscular fracture as its characteristic pattern. The aim of this retrospective study was to investigate intramedullary nailed and plated FHS in terms of outcomes and complications. Materials and Methods: The present study included patients with FHS, treated via either intramedullary nailing or plating within a period of 10 years, with a minimum follow-up of 12 months. Functional outcome was assessed using the age- and sex-adapted Constant-Murley Score (CMS-K). Rates of complications and revision surgeries were registered. Results: Twenty-five patients (18 females, 7 males, age 60.1 ± 14.2 years, range 23-76 years) were included in the study. Nailing was performed in 16 patients (12 females, 4 males, age 62.6 ± 12.4 years), whereas plating was executed in nine patients (6 females, 3 males, age 55.8 ± 17.0 years). Follow-up among all patients was 45.1 ± 26.3 months (range 12-97 months). CMS-K was 70.3 ± 32.3 in the nailing group, with reoperation in four cases, and 76.0 ± 31.0 in the plating group, with one reoperation (p = 0.42). Patients with no metaphyseal fragment displacement (n = 19; CMS-K 76.7 ± 17.3) demonstrated significantly better functional outcomes versus those with secondary displacement of the metaphyseal fragments (n = 6; CMS-K 60.0 ± 17.1), p = 0.046. Conclusions: Comparable acceptable clinical outcome is obtained when comparing nailing with additional open cerclage or lag-screw fixation techniques versus plating with open reduction. However, a higher revision rate was observed after nailing. The correct metaphyseal fragment fixation seems to be crucial to avoid loss of reduction and hence the need for revision surgery, as well as a worse outcome.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas del Húmero , Masculino , Femenino , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Fijación Intramedular de Fracturas/métodos , Cabeza Humeral , Estudios Retrospectivos , Fracturas del Húmero/etiología , Fracturas del Húmero/cirugía , Placas Óseas/efectos adversos , Resultado del Tratamiento
10.
Medicina (Kaunas) ; 59(8)2023 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-37629669

RESUMEN

Background and purpose: Cannulated screws are standard implants for percutaneous fixa-tion of posterior pelvis ring injuries. The choice of whether to use these screws in combination with a washer is still undecided. The aim of this study was to evaluate the biomechanical competence of S1-S2 sacroiliac (SI) screw fixation with and without using a washer across three different screw designs. Material and Methods: Twenty-four composite pelvises were used and an SI joint injury type APC III according to the Young and Burgess classification was simulated. Fixation of the posterior pelvis ring was performed using either partially threaded short screws, fully threaded short screws, or fully threaded long transsacral screws. Biomechanical testing was performed under progressively increasing cyclic loading until failure, with monitoring of the intersegmental and bone-implant movements via motion tracking. Results: The number of cycles to failure and the corresponding load at failure (N) were significantly higher for the fully threaded short screws with a washer (3972 ± 600/398.6 ± 30.0) versus its counterpart without a washer (2993 ± 527/349.7 ± 26.4), p = 0.026. In contrast, these two parameters did not reveal any significant differences when comparing fixations with and without a washer using either partially threaded short of fully threaded long transsacral screws, p ≥ 0.359. Conclusions: From a biomechanical perspective, a washer could be optional when using partially threaded short or fully threaded long transsacral S1-S2 screws for treatment of posterior pelvis ring injuries in young trauma patients. Yet, the omission of the washer in fully threaded short screws could lead to a significant diminished biomechanical stability.


Asunto(s)
Técnicas Histológicas , Pelvis , Humanos , Pacientes , Programas Informáticos , Tornillos Óseos
11.
Medicina (Kaunas) ; 59(8)2023 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-37629740

RESUMEN

Background and Objectives: Providing high-quality care for patients in hand surgery is an everyday endeavor. However, the quality of life (QoL) and working conditions of hand surgeons ensuring these high-quality services need to be investigated. The aim of this study was to evaluate the QoL and working conditions of Swiss hand surgeons. Materials and Methods: A national survey with Swiss hand surgeons was conducted. Standardized questionnaires were completed anonymously online. Core topics included working conditions, QoL, satisfaction with the profession, and aspects of private life. Results: A total of 250 hand surgeons were invited to participate, of which 110 (44.0%) completed the questionnaire. Among all participants, 43.6% stated that they are on call 4-7 days per month, versus 8.2% never being on call. Overall, 84.0% of the residents, 50.0% of the senior physicians, 27.6% of the physicians in leading positions, and 40.6% of the senior consultants/practice owners, as well as 55.1% of the female and 44.3% of the male respondents, felt stressed by their job, even during holidays and leisure time. Out of all participants, 85.4% felt that work affects private relationships negatively. Despite the reported stress, 89.1% would choose hand surgery as a profession again. Less on-call duty (29.1%) and better pay (26.4%) are the most prioritized factors for attractiveness of a position at a hospital. Conclusions: The QoL of Swiss hand surgeons is negatively affected by their workload and working hours. Residents, senior physicians and female surgeons suffer significantly more often from depression, burnout or chronic fatigue in comparison to leading positions, senior consultants/practice owners and male surgeons. Better pay or less on-call duty would make the work more attractive in acute care hospitals.


Asunto(s)
Calidad de Vida , Cirujanos , Humanos , Femenino , Masculino , Condiciones de Trabajo , Ansiedad , Emociones
12.
Medicina (Kaunas) ; 59(4)2023 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-37109698

RESUMEN

Background and Objectives: Pubic ramus fractures are common in compound pelvic injuries known to have an increased rate of morbidity and mortality along with recurrent and chronic pain, impeding a patient's quality of life. The current standard treatment of these fractures is percutaneous screw fixation due to its reduced risk of blood loss and shorter surgery times. However, this is an intricate surgical technique associated with high failure rates of up to 15%, related to implant failure and loss of reduction. Therefore, the aim of this biomechanical feasibility study was to develop and test a novel intramedullary splinting implant for fixation of superior pubic ramus fractures (SPRF), and to evaluate its biomechanical viability in comparison with established fixation methods using conventional partially or fully threaded cannulated screws. Materials and Methods: A type II superior pubic ramus fracture according to the Nakatani classification was created in 18 composite hemi-pelvises via a vertical osteotomy with an additional osteotomy in the inferior pubic ramus to isolate the testing of three SPRF fixation techniques performed in 6 semi-pelvises each using either (1) a novel ramus intramedullary splint, (2) a partially threaded ramus screw, or (3) a fully threaded ramus screw. Results: No significant differences were detected among the fixation techniques in terms of initial construct stiffness and number of cycles to failure, p ≥ 0.213. Conclusion: The novel ramus intramedullary splint can be used as an alternative option for treatment of pubic ramus fractures and has the potential to decrease the rate of implant failures due to its minimally invasive implantation procedure.


Asunto(s)
Fracturas Óseas , Huesos Pélvicos , Humanos , Huesos Pélvicos/lesiones , Estudios de Factibilidad , Calidad de Vida , Fracturas Óseas/cirugía , Fijación de Fractura , Fijación Interna de Fracturas , Fenómenos Biomecánicos
13.
Medicina (Kaunas) ; 59(11)2023 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-38004092

RESUMEN

Background and Objectives: The surgical treatment of proximal humeral shaft fractures usually considers application of either long straight plates or intramedullary nails. By being able to spare the rotator cuff and avoid the radial nerve distally, the implementation of helical plates might overcome the downsides of common fixation methods. The aims of the current study were (1) to explore the biomechanical competence of different plate designs and (2) to compare their performance versus the alternative treatment option of using intramedullary nails. Materials and Methods: Twenty-four artificial humeri were assigned to the following four groups for simulation of an unstable proximal humeral shaft fracture and instrumentation: Group 1 (Straight-PHILOS), Group 2 (MULTILOC-Nail), Group 3 (45°-Helical-PHILOS), and Group 4 (90°-Helical-PHILOS). All specimens underwent non-destructive, quasi-static biomechanical testing under loading in axial compression, torsion in internal/external rotation, and pure bending in four directions, accompanied by motion tracking. Results: Axial stiffness/displacement in Group 2 was significantly higher/smaller than in all other groups (p ≤ 0.010). Torsional displacement in Group 2 was significantly bigger than in all other groups (p ≤ 0.017). Significantly smaller coronal plane displacement was identified in Group 2 versus all other groups (p < 0.001) and in Group 4 versus Group 1 (p = 0.022). Significantly bigger sagittal plane displacement was detected in Group 4 versus all other groups (p ≤ 0.024) and in Group 1 versus Group 2 (p < 0.001). Conclusions: Intramedullary nails demonstrated higher axial stiffness and smaller axial interfragmentary movements compared with all investigated plate designs. However, they were associated with bigger torsional movements at the fracture site. Although 90°-helical plates revealed bigger interfragmentary movements in the sagittal plane, they demonstrated improved resistance against displacements in the coronal plane when compared with straight lateral plates. In addition, 45°-helical plates manifested similar biomechanical competence to straight plates and may be considered a valid alternative to the latter from a biomechanical standpoint.


Asunto(s)
Fijación Intramedular de Fracturas , Humanos , Fijación Intramedular de Fracturas/métodos , Clavos Ortopédicos , Fenómenos Biomecánicos , Fijación Interna de Fracturas , Húmero , Placas Óseas
14.
Medicina (Kaunas) ; 59(2)2023 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-36837571

RESUMEN

Background and Objectives: Proximal humerus fractures (PHFs) are common in the elderly, but the treatment results are often poor. A clear understanding of fracture morphology and distribution of cortical bone loss is important for improved surgical decision making, operative considerations, and new implant designs. The aim of this study was to develop a 3D segmentation fracture mapping technique to create a statistical description of the spatial pattern and cortical bone loss of complex PHFs. Materials and Methods: Fifty clinical computed tomography (CT) scans of complex PHFs and their contralateral intact shoulders were collected. In-house software was developed for semi-automated segmentation and fracture line detection and was combined with manual fracture reduction to the contralateral template in a commercial software. A statistical mean model of these cases was built and used to describe probability maps of the fracture lines and cortical fragments. Results: The fracture lines predominantly passed through the surgical neck and between the tuberosities and tendon insertions. The superior aspects of the tuberosities were constant fragments where comminution was less likely. Some fracture lines passed through the bicipital sulcus, but predominantly at its edges and curving around the tuberosities proximally and distally. Conclusions: A comprehensive and systematic approach was developed for processing clinical CT images of complex fractures into fracture morphology and fragment probability maps and applied on PHFs. This information creates an important basis for better understanding of fracture morphology that could be utilized in future studies for surgical training and implant design.


Asunto(s)
Enfermedades Óseas Metabólicas , Fracturas Conminutas , Fracturas del Hombro , Humanos , Anciano , Fijación Interna de Fracturas , Fracturas del Hombro/cirugía , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Fracturas Conminutas/cirugía
15.
Arch Orthop Trauma Surg ; 142(12): 3787-3796, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34748055

RESUMEN

BACKGROUND: Recently, two novel concepts for intramedullary nailing of trochanteric fractures using a helical blade or interlocking dual screws have demonstrated advantages as compared to standard single-screw systems. However, these two concepts have not been subjected to a direct biomechanical comparison so far. The aims of this study were to investigate in a human cadaveric model with low bone quality (1) the biomechanical competence of nailing with the use of a helical blade versus interlocking screws, and (2) the effect of cement augmentation on the fixation strength of the helical blade. METHODS: Twelve osteoporotic and osteopenic human cadaveric femoral pairs were assigned for pairwise implantation using either a short TFN-ADVANCED Proximal Femoral Nailing System (TFNA) with a helical blade head element or a short TRIGEN INTERTAN Intertrochanteric Antegrade Nail (InterTAN) with interlocking screws. Six osteoporotic femora, implanted with TFNA, were augmented with bone cement. Four groups were created: group 1 (TFNA) paired with group 2 (InterTAN), both consisting of osteopenic specimens, and group 3 (TFNA augmented) paired with group 4 (InterTAN), both consisting of osteoporotic specimens. An unstable trochanteric AO/OTA 31-A2.2 fracture was simulated and all specimens were tested until failure under progressively increasing cyclic loading. RESULTS: Stiffness in group 3 was significantly higher versus group 4, p = 0.03. Varus (°) and femoral head rotation around the femoral neck axis (°) after 10,000 cycles were 1.9 ± 1.0/0.3 ± 0.2 in group 1, 2.2 ± 0.7/0.7 ± 0.4 in group 2, 1.5 ± 1.3/0.3 ± 0.2 in group 3 and 3.5 ± 2.8/0.9 ± 0.6 in group 4, being significantly different between groups 3 and 4, p = 0.04. Cycles to failure and failure load (N) at 5° varus or 10° femoral head rotation around the neck axis in groups 1-4 were 21,428 ± 6020/1571.4 ± 301.0, 20,611 ± 7453/1530.6 ± 372.7, 21,739 ± 4248/1587.0 ± 212.4 and 18,622 ± 6733/1431.1 ± 336.7, being significantly different between groups 3 and 4, p = 0.04. CONCLUSIONS: Nailing of trochanteric femoral fractures with use of helical blades is comparable to interlocking dual screws fixation in femoral head fragments with low bone quality. Bone cement augmentation of helical blades provides significantly greater fixation strength compared to interlocking screws constructs.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de Cadera , Humanos , Tornillos Óseos , Cementos para Huesos , Uñas , Cadáver , Fracturas de Cadera/cirugía , Clavos Ortopédicos , Fenómenos Biomecánicos
16.
Medicina (Kaunas) ; 58(6)2022 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-35744007

RESUMEN

Background and Objectives: Three-dimensional planning and guided osteotomy utilizing patient-specific instrumentation (PSI) with the contralateral side used as a reference have been proven as effective in the treatment of malunions following complex fractures of the distal radius. However, this approach has not yet been described in relation to fracture reduction of the distal radius. The aim of this study was to assess the technical and logistical feasibility of computer-assisted surgery in a clinical setting using PSI for fracture reduction and fixation. Materials and Methods: Five patients with varied fracture patterns of the distal radius underwent operative treatment with using PSI. The first applied PSI guide allowed specific and accurate placement of Kirschner wires inside the multiple fragments, with subsequent concurrent reduction using a second guide. Results: Planning, printing of the guides, and operations were performed within 5.6 days on average (range of 1-10 days). All patients could be treated within a reasonable period of time, demonstrating good outcomes, and were able to return to work after a follow-up of three months. Mean wrist movements (°) were 58 (standard deviation (SD) 21) in flexion, 62 (SD 15) in extension, 73 (SD 4) in pronation and 74 (SD 10) in supination at a minimum follow-up of 6 months. Conclusions: Three-dimensional planned osteosynthesis using PSI for treatment of distal radius fractures is feasible and facilitates reduction of multiple fracture fragments. However, higher costs must be taken into consideration for this treatment.


Asunto(s)
Fracturas del Radio , Hilos Ortopédicos , Fijación de Fractura , Fijación Interna de Fracturas , Humanos , Osteotomía/métodos , Fracturas del Radio/cirugía , Rango del Movimiento Articular , Resultado del Tratamiento
17.
Medicina (Kaunas) ; 58(6)2022 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-35744036

RESUMEN

Background and Objectives: Freehand distal interlocking of intramedullary nails is technically demanding and prone to handling issues. It requires precise placement of a screw through the nail under fluoroscopy guidance and can result in a time consuming and radiation expensive procedure. Dedicated training could help overcome these problems. The aim of this study was to assess construct and face validity of new Digitally Enhanced Hands-On Surgical Training (DEHST) concept and device for training of distal interlocking of intramedullary nails. Materials and Methods: Twenty-nine novices and twenty-four expert surgeons performed interlocking on a DEHST device. Construct validity was evaluated by comparing captured performance metrics-number of X-rays, nail hole roundness, drill tip position and drill hole accuracy-between experts and novices. Face validity was evaluated with a questionnaire concerning training potential and quality of simulated reality using a 7-point Likert scale. Results: Face validity: mean realism of the training device was rated 6.3 (range 4-7). Training potential and need for distal interlocking training were both rated with a mean of 6.5 (range 5-7), with no significant differences between experts and novices, p ≥ 0.234. All participants (100%) stated that the device is useful for procedural training of distal nail interlocking, 96% wanted to have it at their institution and 98% would recommend it to colleagues. Construct validity: total number of X-rays was significantly higher for novices (20.9 ± 6.4 versus 15.5 ± 5.3, p = 0.003). Success rate (ratio of hit and miss attempts) was significantly higher for experts (novices hit: n = 15; 55.6%; experts hit: n = 19; 83%, p = 0.040). Conclusion: The evaluated training device for distal interlocking of intramedullary nails yielded high scores in terms of training capability and realism. Furthermore, construct validity was proven by reliably discriminating between experts and novices. Participants indicate high further training potential as the device may be easily adapted to other surgical tasks.


Asunto(s)
Clavos Ortopédicos , Fijación Intramedular de Fracturas , Tornillos Óseos , Fluoroscopía , Fijación Intramedular de Fracturas/métodos , Humanos , Radiografía
18.
Medicina (Kaunas) ; 58(11)2022 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-36422175

RESUMEN

Background and Objectives: Intramedullary nailing of trochanteric fractures can be challenging and sometimes the clinical situation does not allow perfect implant positioning. The aim of this study was (1) to compare in human cadaveric femoral heads the biomechanical competence of two recently launched cephalic implants inserted in either an ideal (centre-centre) or less-ideal anterior off-centre position, and (2) to investigate the effect of bone cement augmentation on their fixation strength in the less-ideal position. Materials and Methods: Fourty-two paired human cadaveric femoral heads were assigned for pairwise implantation using either a TFNA helical blade or a TFNA screw as head element, implanted in either centre-centre or 7 mm anterior off-centre position. Next, seven paired specimens implanted in the off-centre position were augmented with bone cement. As a result, six study groups were created as follows: group 1 with a centre-centre positioned helical blade, paired with group 2 featuring a centre-centre screw, group 3 with an off-centre positioned helical blade, paired with group 4 featuring an off-centre screw, and group 5 with an off-centre positioned augmented helical blade, paired with group 6 featuring an off-centre augmented screw. All specimens were tested until failure under progressively increasing cyclic loading. Results: Stiffness was not significantly different among the study groups (p = 0.388). Varus deformation was significantly higher in group 4 versus group 6 (p = 0.026). Femoral head rotation was significantly higher in group 4 versus group 3 (p = 0.034), significantly lower in group 2 versus group 4 (p = 0.005), and significantly higher in group 4 versus group 6 (p = 0.007). Cycles to clinically relevant failure were 14,919 ± 4763 in group 1, 10,824 ± 5396 in group 2, 10,900 ± 3285 in group 3, 1382 ± 2701 in group 4, 25,811 ± 19,107 in group 5 and 17,817 ± 11,924 in group 6. Significantly higher number of cycles to failure were indicated for group 1 versus group 2 (p = 0.021), group 3 versus group 4 (p = 0.007), and in group 6 versus group 4 (p = 0.010). Conclusions: From a biomechanical perspective, proper centre-centre implant positioning in the femoral head is of utmost importance. In cases when this is not achievable in a clinical setting, a helical blade is more forgiving in the less ideal (anterior) malposition when compared to a screw, the latter revealing unacceptable low resistance to femoral head rotation and early failure. Cement augmentation of both off-centre implanted helical blade and screw head elements increases their resistance against failure; however, this effect might be redundant for helical blades and is highly unpredictable for screws.


Asunto(s)
Cementos para Huesos , Fracturas de Cadera , Humanos , Clavos Ortopédicos , Tornillos Óseos , Fracturas de Cadera/cirugía , Cadáver
19.
J Orthop Traumatol ; 23(1): 30, 2022 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-35809109

RESUMEN

BACKGROUND: Some patients have demonstrated evidence of heterotopic ossification (HO) following total hip arthroplasty (THA). Selective and non-selective non-steroidal anti-inflammatory drugs (NSAIDs) are used as prophylaxis for HO following THA. This meta-analysis compared selective versus non-selective NSAIDs as prophylaxis for HO following THA. MATERIAL AND METHODS: The present study was conducted according to the PRISMA 2020 guidelines. All the clinical investigations comparing selective versus non-selective NSAIDs as prophylaxis for HO following THA were accessed in February 2022. An assessment of the methodological quality and statistical analyses were performed through the risk of bias summary tool of the Review Manager 5.3 software (Cochrane Collaboration, Copenhagen). The modified Brooker staging system was used to rate the efficacies of the interventions. RESULTS: Data from 8 studies and 1526 patients were collected. 60.8% were female. No difference was found in the sample size, mean age, and percentage of females between the two groups at baseline. No statistically significant difference was found between selective and non-selective NSAIDs in term of efficacy. 72% (1078 of 1502) of the patients were classified as Brooker 0, 21% (322 of 1502) as Brooker I, 5% (80 of 1502) as Brooker II, 1% (16 of 1502) as Brooker III, and 0.1% (2 of 1502) as Brooker IV. CONCLUSION: Selective and non-selective NSAIDs were equally effective when used as prophylaxis for HO following THA. LEVEL OF EVIDENCE: Level III, systematic review and meta-analysis.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Osificación Heterotópica , Antiinflamatorios no Esteroideos/uso terapéutico , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Humanos , Masculino , Osificación Heterotópica/etiología , Osificación Heterotópica/prevención & control , Resultado del Tratamiento
20.
J Shoulder Elbow Surg ; 30(9): 2022-2031, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33545338

RESUMEN

BACKGROUND: Rock climbers are particularly susceptible to shoulder injuries due to repetitive upper-limb movements on vertical or overhanging terrain. However, the long-term effects of prolonged climbing on the shoulder joints are still unknown. PURPOSE: The purpose of this study was to analyze the prevalence of pain and degenerative changes in the shoulder joints after high-level rock climbing over at least 25 years. We hypothesized that specific climber-associated patterns of degeneration would be found. METHODS: Thirty-one adult male high-level rock climbers were compared to an age- and sex-matched control group of 31 nonclimbers. All participants underwent a detailed interview, standardized clinical examination, and bilateral (climbers) or unilateral (nonclimbers, dominant side) magnetic resonance imaging (MRI) scans. Clinical and MRI findings of the groups were compared. RESULTS: The lifetime prevalence of shoulder pain in the rock climbers was 77%. The rock climbers had significantly more abnormalities in the labrum (82% vs. 52%; P = .002), long biceps tendon (53% vs. 23%; P = .006), and cartilage (28% vs. 3%; P = .005). These increased changes positively correlated with climbing intensity. There were no differences between the 2 groups with respect to rotator cuff tendon pathology (68% vs. 58%; P = .331) and acromioclavicular joint degeneration (88% vs. 90%; P = .713). Despite the increased degenerative changes in the rock climbers, their Constant score (CS) was still better than that of the nonclimbers (CS 94, interquartile range [IQR] 92-97, vs. CS 93, IQR 91-95; P = .019). CONCLUSIONS: Prolonged high-level rock climbing leads to a high prevalence of shoulder pain and increased degenerative changes to the labrum, long biceps tendon, and cartilage. However, it is not related to any restriction in shoulder function.


Asunto(s)
Traumatismos en Atletas , Montañismo , Lesiones del Hombro , Adulto , Humanos , Imagen por Resonancia Magnética , Masculino , Hombro , Lesiones del Hombro/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA