Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-36974970

RESUMEN

AIMS: In patients with prolonged atrioventricular (AV) conduction and pacemaker (PM) indication due to sinus node disease (SND) or intermittent AV-block who do not need continuous ventricular pacing (VP), it may be difficult to determine which strategy to adopt. Currently, the standard of care is to minimize unnecessary VP by specific VP avoidance (VPA) algorithms. The superiority of this strategy over standard DDD or DDD rate-responsive (DDD/DDDR) in improving clinical outcomes is controversial, probably owing to the prolongation of the atrialventricular conduction (PR interval) caused by the algorithms. Conduction system pacing (CSP) may offer the most physiological-VP approach, providing appropriate AV conduction and preventing pacing-induced dyssynchrony. METHODS AND RESULTS: PhysioVP-AF is a prospective, controlled, randomized, single-blind trial designed to determine whether atrial-synchronized conduction system pacing (DDD-CSP) is superior to standard DDD-VPA pacing in terms of 3-year reduction of persistent-AF occurrence. Cardiovascular hospitalization, quality-of-life, and safety will be evaluated. Patients with indication for permanent DDD pacing for SND or intermittent AV-block and prolonged AV conduction (PR interval > 180 ms) will be randomized (1:1 ratio) to DDD-VPA (VPA-algorithms ON, septal/apex position) or to DDD-CSP (His bundle or left bundle branch area pacing, AV-delay setting to control PR interval, VPA-algorithms OFF). Approximately 400 patients will be randomized in 24 months in 13 Italian centres. CONCLUSION: The PhysioVP-AF study will provide an essential contribution to patient management with prolonged AV conduction and PM indication for sinus nodal disease or paroxysmal 2nd-degree AV-block by determining whether CSP combined with a controlled PR interval is superior to standard management that minimizes unnecessary VP in terms of reducing clinical outcomes.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Estudios Prospectivos , Método Simple Ciego , Síndrome del Seno Enfermo/complicaciones , Síndrome del Seno Enfermo/diagnóstico , Síndrome del Seno Enfermo/terapia
2.
Molecules ; 28(18)2023 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-37764449

RESUMEN

This paper reviews the current knowledge regarding modifications to chlorophylls during the processing of green table olives treated with alkali. Particular attention is given to the pheophytinization reactions (substitution of Mg2+ by 2H+ in the chlorophyll chromophore group) that can take place because of pH and/or temperature changes and the possible sequential substitution of the 2H+ with Cu2+ within the chlorophyll porphyrin ring. These reactions may have a direct impact on the commercial value of olive productions as some naturally forming Cu-chlorophylls complexes (i) are identical to strictly forbidden colorants for table olives (E141) and (ii) have been identified as responsible for the unwelcome appearance of the so-called green staining alteration (characterized by bluish-green zones distributed over the olive skin of the drupes).


Asunto(s)
Olea , Porfirinas , Olea/química , Cobre/química , Clorofila/química
3.
Molecules ; 28(10)2023 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-37241990

RESUMEN

Chlorophyll pigments are thought to be responsible for the highly appreciated green color of unfermented Castelvetrano-style table olives, but no studies have considered the effects of a controlled addition of copper during storage or packaging at the industrial level. For this purpose, chlorophyll derivatives were analyzed in Nocellara cultivar table olives debittered industrially using the Castelvetrano method, via means of HPLC and MS analyses, following the addition of copper in alkaline brines stored at 4 °C for 3 months in 220 L barrels, and during the subsequent storage in acid brines in commercial 400 g packages at 4 °C for up to 18 months. The presence of copper in storage or in packaging brines both contributed significantly to maintaining the green color of the olives, which was associated with a specific pattern of chlorophyll derivatives, as evidenced by principal component analysis. Notably, re-greening was rapidly achievable also for olives that had yellowed for 18 months at a copper concentration below the limit of EU legislation. Finally, by means of PCA, we also demonstrated that a short-term thermic treatment can work as an accelerated predictive tool in determining the fate of chlorophyll derivatives.


Asunto(s)
Cobre , Olea , Cobre/análisis , Clorofila/análisis , Sales (Química) , Fermentación
4.
Indian Pacing Electrophysiol J ; 23(6): 177-182, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37598755

RESUMEN

INTRODUCTION: Restoring physiological cardiac electrical activity in patients with conduction disease can be crucial for the survival and quality of life. Conduction system pacing (CSP) is a valuable option, although it is limited by technical challenges in difficult anatomies. 3D electroanatomical mapping (3D-EAM) can support CSP ensuring high electro-anatomical precision and low fluoroscopy. OBJECTIVES: We evaluated the feasibility and effectiveness of a systematic 3D-EAM use to guide CSP in difficult anatomical scenarios (highly dilated atria, congenital cardiomyopathies, failed biventricular implants (BiV) and pacing-induced cardiomyopathy (PICM)). METHODS: Forty-three consecutive patients (27 males, 75 ± 10 years old) with standard pacing indications and difficult anatomical scenarios were included. The right atrium, His cloud, and atrio-ventricular septum were reconstructed by 3D-EAM. The His bundle (HB) was the initial target, while left bundle branch area pacing (LBBAP) was aimed at in case of unsatisfactory parameters, sub-optimally paced QRS, or impossibility of reaching the HB. RESULTS: CSP was successful in 37 (86%) patients (15 HBP; 22 LBBAP). Mean mapping, fluoroscopy, and procedural times were 18 ± 7 min, 7 ± 5 min, 98 ± 47 min, respectively. The mean pacing threshold, R wave sensing, and pacing impedance of CSP lead were 1.2 ± 0.5V@0.5ms, 11.4 ± 6.2 mV, 736 ± 306 Ω, respectively. Baseline and paced QRS were 139 ± 38 ms and 114 ± 23 ms, respectively. No procedural complications were observed. CONCLUSIONS: 3D-EAM allowed the accurate definition of the His cloud and high ventricular septum and effectively guided CSP. It facilitated CSP in complex anatomies, with a procedural success rate of 86%. The results were satisfactory and reproducible, with acceptable fluoroscopy and procedural times.

5.
Molecules ; 27(3)2022 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-35163926

RESUMEN

The fate of phenolic compounds in oil and food during cooking vary according to the type of cooking. From a nutritional point of view, reviews largely suggest a preference for using extra-virgin olive oil at a low temperature for a short time, except for frying and microwaving, for which there appears to be no significant advantages compared to olive oil. However, due to the poorly pertinent use of terminology, the different protocols adopted in studies aimed at the same objective, the different type and quality of oils used in experiments, and the different quality and quantity of PC present in the used oils and in the studied vegetables, the evidence available is mainly contradictory. This review tries to reanalyse the main experimental reports on the fate, accessibility and bioavailability of phenolic compounds in cooking oils and cooked vegetables, by considering different cooking techniques and types of oil and foods, and distinguishing experimental findings obtained using oil alone from those in combination with vegetables. The re-analysis indicates that incomplete and contradictory observations have been published in the last few years and suggests that further research is necessary to clarify the impact of cooking techniques on the phenolic compounds in oil and vegetables during cooking, especially when considering their nutritional properties.


Asunto(s)
Culinaria/métodos , Calor , Aceite de Oliva/química , Fenoles/análisis
6.
J Cardiovasc Electrophysiol ; 32(1): 110-116, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33179400

RESUMEN

INTRODUCTION: In patients with sinus node disease (SND), the dual-chamber pacemaker (PM) is programmed in DDDR mode with an algorithm to avoid unnecessary right ventricular (RV) pacing. This pacing mode may prolong PR interval with consequently atrioventricular (AV) asynchrony which is associated with a higher risk of atrial fibrillation (AF). We evaluate whether preserving AV synchrony by setting a fixed AV delay during physiological RV pacing, that is, His bundle pacing (HBP), could reduce the risk of AF occurrence in comparison with a standard pacing mode with an algorithm to avoid unnecessary RV pacing (DDD-VPA). METHODS AND RESULTS: We collected retrospective data from 313 consecutive patients who had undergone PM for SND. The first occurrence of persistent AF (>7 consecutive days) as a function of the pacing mode was evaluated. HBP and DDD-VPA were implemented in 82 and 231 patients, respectively. Persistent AF occurred in 128 (40.9%) patients over a median follow-up of 70 months (67-105). The DDD-VPA pacing mode was significantly correlated with the occurrence of persistent AF only when the basal PR was long (>180 ms). The risk of persistent AF was significantly lower in patients on HBP than in those on DDD-VPA, adjusted HR = .57 (95% CI, .36- .89, p=.014). Other independent predictors of persistent AF occurrence were: A history of AF (HR = 3.91; 95% CI, 2.48-6.19, p = .001), age, and long PR interval (HR = 2.98; 95% CI, 2.00-4.43, p=.001). CONCLUSION: In SND patients and long basal PR interval, the HBP may reduce the risk of persistent AF in comparison with the DDD-VPA.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Humanos , Estudios Retrospectivos , Síndrome del Seno Enfermo/diagnóstico , Síndrome del Seno Enfermo/terapia
7.
Molecules ; 26(2)2021 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-33477637

RESUMEN

This review reports recent knowledge on the role of ingredients (barley, hop and yeasts), including genetic factors, on the final yield of phenolic compounds in beer, and how these molecules generally affect resulting beer attributes, focusing mainly on new attempts at the enrichment of beer phenols, with fruits or cereals other than barley. An entire section is dedicated to health-related effects, analyzing the degree up to which studies, investigating phenols-related health effects of beer, have appropriately considered the contribution of alcohol (pure or spirits) intake. For such purpose, we searched Scopus.com for any kind of experimental model (in vitro, animal, human observational or intervention) using beer and considering phenols. Overall, data reported so far support the existence of the somehow additive or synergistic effects of phenols and ethanol present in beer. However, findings are inconclusive and thus deserve further animal and human studies.


Asunto(s)
Bebidas Alcohólicas/análisis , Cerveza/análisis , Grano Comestible/química , Estado de Salud , Hordeum/química , Fenoles/metabolismo , Levaduras/química , Animales , Humanos
8.
Semin Cancer Biol ; 56: 185-195, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-28912082

RESUMEN

The mitogen-activated protein kinases (MAPKs) are fundamental in inflammation and cancer control, through the crosstalk between the redox regulated nuclear factor E2-related factor 2 (Nrf2) and nuclear factor-kB (NFκB) gene expression. MAPKs regulate various cellular activities involved in cancer progression, including proliferation, apoptosis and immune escape and blockade of upstream kinases is a current therapeutic strategy. However, these therapies are associated with some adverse effects and with the paradoxical activation of the MAPKs pathway. In the context of cancer prevention and treatment, it has been suggested that dietary factors are able to modulate cancer initiation and progression by interacting with the MAPKs. Within these dietary factors, virgin olive oil (VOO) is of particular interest due to its content in squalene, already used as drug delivery system in cancer therapy. The aim of this review is to discuss the studies pointing to the effects of olive-derived foodstuff and nutraceuticals on MAPKs signalling cascades. The reviewed experimental studies suggest that the stress-activated JNK and p38 MAPKs could be targets of olive-derived nutraceuticals. The latter, including phytochemicals from olive cultivation and processing wastes, could be adjuvants in chemotherapies, whereas VOO could be considered a "natural delivery system" of bioactive phytochemicals due to its high content in squalene.


Asunto(s)
Sistema de Señalización de MAP Quinasas , Neoplasias/metabolismo , Animales , Antineoplásicos Fitogénicos/química , Antineoplásicos Fitogénicos/farmacología , Antineoplásicos Fitogénicos/uso terapéutico , Quimioprevención , Modelos Animales de Enfermedad , Susceptibilidad a Enfermedades , Sistemas de Liberación de Medicamentos , Humanos , Sistema de Señalización de MAP Quinasas/efectos de los fármacos , Nanopartículas/química , Neoplasias/tratamiento farmacológico , Neoplasias/etiología , Neoplasias/prevención & control , Olea/química , Estrés Oxidativo , Extractos Vegetales/química , Extractos Vegetales/farmacología , Extractos Vegetales/uso terapéutico , Nanomedicina Teranóstica
9.
J Cardiovasc Electrophysiol ; 31(4): 805-812, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31976602

RESUMEN

INTRODUCTION: His bundle pacing (HBP) is the most physiological pacing. The standard technique based on fluoroscopic approach might be challenging and fluoro consuming. Targeting the His guided exclusively by the electrical signals could enable a precise lead implant, thus reducing fluoroscopy time (FT) and X-ray dose, desirable both for patients and operators. The aim of the study is to evaluate the feasibility, efficacy, and safety both acutely and at 30 days of the electrogram (EGM)-guided HBP with minimal or no fluoroscopy. METHODS AND RESULTS: Between October and December 2018, 41 consecutive patients underwent EGM-guided HBP. Successful HBP was obtained in 39 (95%) patients, (30 males, 78 ± 10 years). Selective HBP (S-HBP) was achieved in 23 (59%), nonselective HBP (NS-HBP) in 16 (41%) patients. The final HBP lead position was reached in 31 (79.4%) patients without fluoroscopy, only guided by electrical signals. In eight patients a minimal fluoroscopy (mean, 8 seconds) has been required. The sheath's cutting and the slack of the lead were routinely performed under fluoroscopy. No difference was observed in FT for HBP lead placement in S-HBP and NS-HBP (mean, 8.1 ± 25 vs 7.5 ± 20 seconds, P = .8; median value 0 vs 0 seconds). No differences were observed in FT for the entire procedure, total dose area product and total procedural time in S-HBP and NS-HBP. Lead dislodgement occurred in one (2.6%) patient 1 day after the procedure. CONCLUSIONS: HBP could be performed safely and efficiently using the EGMs, with minimal or no fluoroscopy. Fluoroscopy was required during sheath removal and atrial lead placement.


Asunto(s)
Potenciales de Acción , Arritmias Cardíacas/terapia , Fascículo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Marcapaso Artificial , Radiografía Intervencional , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Fascículo Atrioventricular/diagnóstico por imagen , Estimulación Cardíaca Artificial/efectos adversos , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Dosis de Radiación , Exposición a la Radiación/prevención & control , Radiografía Intervencional/efectos adversos , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
10.
J Cardiovasc Electrophysiol ; 30(9): 1594-1601, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31310410

RESUMEN

INTRODUCTION: Several single-center short-term studies have demonstrated the feasibility, safety, and positive clinical outcomes of permanent His bundle pacing (HBP). We performed a retrospective study to evaluate long-term technical and safety performances of HBP in a large population of pacemaker patients from two different centers. METHODS AND RESULTS: The analysis includes 844 patients (345 female, mean age = 75 ± 9 years) who underwent successful permanent HBP for pacemaker indications from 2004 to 2016. The main endpoints were long term electrical performances including pacing threshold, sensing, impedance, and freedom from pacing related complications. The pacing indication was AV Block in 348 (41.2%) patients, sinus node disease in 147 (17.4%), any bradycardia indication in patients with atrial fibrillation in 335 (39.7%) patients and need for cardiac resynchronization therapy in 14 (1.7%) patients. Mean pacing capture thresholds and sensed R waves were 1.6 V and 5.8 mV, respectively at implant and 2.0 V and 6.1 mV at chronic follow-up. During the median follow up of 3 years (interquartile range = 1-6 years), HBP was free of any complication in 91.6% of patients. In the first 368 patients, HBP was achieved using a deflectable curve delivery system, while in 476 using the fixed curve sheath. A significant difference was found in the thresholds (2.4 ± 1.0 V and 1.7 ± 1.1 V, P < .001, respectively) and complications (11.9% and 4.2%, P < .001, respectively) between the two groups. CONCLUSIONS: Permanent HBP was safe and effective during long-term follow-up. The fixed curved delivery sheath offered significantly better electrical parameters and reliability over time. The results of this multicenter study are consistent with recent studies.


Asunto(s)
Bloqueo Atrioventricular/terapia , Bradicardia/terapia , Fascículo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial , Marcapaso Artificial , Síndrome del Seno Enfermo/terapia , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/fisiopatología , Bradicardia/diagnóstico , Bradicardia/fisiopatología , Estimulación Cardíaca Artificial/efectos adversos , Falla de Equipo , Femenino , Frecuencia Cardíaca , Humanos , Italia , Masculino , Persona de Mediana Edad , Pennsylvania , Estudios Retrospectivos , Síndrome del Seno Enfermo/diagnóstico , Síndrome del Seno Enfermo/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
11.
Europace ; 20(11): e171-e178, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29294014

RESUMEN

Aims: Right bundle branch block (RBBB) typically presents with only delayed right ventricular activation. However, some patients with RBBB develop concomitant delayed left ventricular (LV) activation. Such patients may show a specific electrocardiographic (ECG) pattern resembling RBBB in the precordial leads in association with an insignificant S-wave in lateral limb leads (atypical RBBB). We therefore postulated that the ECG pattern of atypical RBBB might be able to identify a subgroup of patients likely to respond to cardiac resynchronization therapy (CRT). The purpose of this study was to assess the impact of RBBB ECG morphology on CRT response in patients with heart failure (HF). Methods and results: We evaluated the echocardiographic clinical response of 66 patients with RBBB treated with CRT and followed up for almost 2 years. The patients were divided electrocardiographically into 2 groups: 31 with typical RBBB and 35 with atypical RBBB. Responders were classified in terms of reduction in LV end-systolic volume index (ESVi) ≥ 15% or reduction in the New York Heart Association (NYHA) Class ≥ 1 or Packer score variation (NYHA response with no HF-related hospitalization events or death). The atypical RBBB group presented a longer LV activation time compared with the typical RBBB group (111.9 ± 17.6 vs. 73.2 ± 15.4 ms; P < 0.001). In the atypical and typical RBBB groups, respectively, 71.4% and 19.4% of patients were ESVi responders (P = 0.001) 74.3% and 32.3% were NYHA responders (P = 0.002); similarly, 71.4% and 29.0% of patients exhibited a 2-year Packer score of 0 (P = 0.002). Conclusion: Patients with atypical RBBB, which is a pattern highly suggestive of concomitant delayed LV conduction, may show a satisfactory response to CRT.


Asunto(s)
Bloqueo de Rama , Terapia de Resincronización Cardíaca , Ecocardiografía/métodos , Sistema de Conducción Cardíaco/fisiopatología , Insuficiencia Cardíaca , Ventrículos Cardíacos/fisiopatología , Anciano , Bloqueo de Rama/complicaciones , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Electrocardiografía/métodos , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud
12.
Heart Lung Circ ; 27(2): 190-198, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28487060

RESUMEN

BACKGROUND: Available studies have already identified age, heart rate (HR) and systolic blood pressure (SBP) as strong predictors of early mortality in acute pulmonary embolism (PE). MATERIAL AND METHODS: One-hundred-seventy patients, with acute PE confirmed on computed tomography angiography (CTA) were enrolled. Thrombolysis In Myocardial Infarction (TIMI) risk index (TRI) was calculated using the formula [heart rate (HR) x (AGE/102)/ systolic blood pressure (SBP)]. Study outcomes were 30-day mortality and/or clinical deterioration. RESULTS: Receiver operating characteristics (ROC) curve revealed that a TRI ≥45 was highly specific for both outcomes (AUC 0.91, 95% CI 0.83-0.98, p<0.0001) with a positive predictive value (PPV) and negative predictive value (NPV) of 8.3 and 96% for 30-day mortality while PPV and NPV for 30-day mortality and/or clinical deterioration were 21.1 and 98.2%, respectively. Multivariate regression analysis showed that TRI ≥45 was an independent predictor of 30-day mortality (O.R. 22.24, 95% CI 2.54-194.10, p=0.005) independently from positive cTnI and RVD (O.R. 9.57, 95% CI 1.88-48.78, p=0.007; OR 24.99, 95% CI 2.84-219.48, p=0.004). Similarly, 30-day mortality and/or clinical deterioration was predicted by TRI ≥45 (O.R. 11.57, 95% CI 2.36-56.63, p=0.003) and thrombolysis (3.83, 95% CI 1.04-14.09, p=0.043), independently from age, RVD and positive cTnI. Cox regression analysis confirmed the role of TRI as independent predictor for both outcomes. Mantel-Cox analysis showed that after 30-day follow-up there was a statistically significant difference in the distribution of survival between patients with and without TRI ≥45 [log rank (Mantel-Cox) chi-square 17.04, p<0.0001]. CONCLUSIONS: Thrombolysis In Myocardial Infarction (TIMI) risk index (TRI) predicted both 30-days mortality (all-causes) and/or clinical deterioration in patients with acute PE.


Asunto(s)
Heparina/administración & dosificación , Embolia Pulmonar/tratamiento farmacológico , Medición de Riesgo/métodos , Terapia Trombolítica/métodos , Enfermedad Aguda , Anciano , Anticoagulantes/administración & dosificación , Angiografía por Tomografía Computarizada , Relación Dosis-Respuesta a Droga , Femenino , Estudios de Seguimiento , Humanos , Italia/epidemiología , Masculino , Pronóstico , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/mortalidad , Curva ROC , Tasa de Supervivencia/tendencias , Factores de Tiempo
13.
Food Microbiol ; 63: 239-247, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28040175

RESUMEN

Table olives are widely consumed worldwide but, due to the presence of NaCl in fermenting brines, they contain high levels of sodium. A promising strategy to lower sodium content is the reduction or substitution of NaCl in brines with other chlorides. However, these procedures may impact safety, spoilage, as well as quality and technological properties, including the evolution and final composition of the fermenting microbiota. In the present work the effects of partially replacing NaCl with KCl in fermenting brines on the microbiological quality of Nocellara del Belice olives produced by Spanish style (Sivigliano) or Castelvetrano methods have been analyzed. In both cases, the fermentation steps were performed in parallel, in brines containing either NaCl alone, or partially replaced with different proportions of KCl (25, 50 and 75%), while maintaining a final saline concentration of 9% (Sivigliano method) or 7% (Castelvetrano). To compare microbial dynamics in the experimental brines, changes in bacterial ecology were monitored during fermentation with a polyphasic approach, including both microbiological methods and culture-independent techniques based on DGGE and NGS analysis. The main microbial groups detected in the olive microbiota from both production procedures were LAB and yeasts. Overall, the data demonstrate that partial replacement of NaCl with KCl does not increase the risk of contamination, nor the overgrowth of pathogens or spoiler microbes.


Asunto(s)
Fermentación , Lactobacillaceae/efectos de los fármacos , Microbiota/fisiología , Olea/microbiología , Sales (Química)/química , Cloruro de Sodio/análisis , Biodiversidad , Reactores Biológicos , Microbiología de Alimentos , Inocuidad de los Alimentos , Concentración de Iones de Hidrógeno , Lactobacillaceae/genética , Microbiota/genética , Reacción en Cadena de la Polimerasa , Cloruro de Potasio/análisis , Cloruro de Potasio/farmacología , Cloruro de Sodio/farmacología , Levaduras/genética , Levaduras/aislamiento & purificación , Levaduras/fisiología
14.
Int J Food Sci Nutr ; 68(5): 538-545, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27931126

RESUMEN

Fatty acids and bioactive lipophilic and hydrophilic compounds (tocopherols, ß-carotene, lutein, squalene, total polyphenols and secoiridoids) in monocultivar Italian extra-virgin olive oil (EVOO) samples produced from the Leccino cultivar and six other yet uncharacterised cultivars (Rustica, Carpinetana, Dritta, Gentile di Chieti and Intosso) were analysed, also taking into account the effect of the type of decanter used for the oil extraction. Significant differences among cultivars were found for α-tocopherol and squalene, but not for carotenoids. Among phenols, cultivars significantly influenced oleuropein and ligstroside aglycones contents, but not those of the dialdehydic form of decarboxymethyl elenolic acid linked neither to tyrosol nor hydroxytyrosol. As previously reported, phenol is quantitatively affected by the type of decanter used for oil extraction. Accordingly, we found that the two-phases decanter preserved in the oil 1.5 times more phenolic compounds as compared with three-phases, whereas it did not influence the amount of lipophilic compounds. Moreover, our data statistically support the finding that type of decanter affects phenols also qualitatively. In fact, the two-phases decanter preferably preserved more the hydroxytyrosol secoiridoid derivatives than the tyrosol ones. Our results from one hand characterise for the first time oils previously unreported, from the other give some new indications on the relative role of factors relevant for the achievement of biologically active extra-virgin oil, i.e. the cultivar and technological ones.


Asunto(s)
Iridoides/química , Luteína/química , Aceite de Oliva/química , Escualeno/química , alfa-Tocoferol/química , beta Caroteno/química , Análisis de los Alimentos , Italia
15.
J Cardiovasc Electrophysiol ; 27(7): 840-5, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27094359

RESUMEN

INTRODUCTION: The longevity of defibrillators (ICD) is extremely important from both a clinical and economic perspective. We studied the reasons for device replacement, the longevity of removed ICD, and the existence of possible factors associated with shorter service life. METHODS AND RESULTS: Consecutive patients who underwent ICD replacement from March 2013 to May 2015 in 36 Italian centers were included in this analysis. Data on replaced devices were collected. A total of 953 patients were included in this analysis. In 813 (85%) patients the reason for replacement was battery depletion, while 88 (9%) devices were removed for clinical reasons and the remaining 52 because of system failure (i.e., lead or ICD generator failure or a safety advisory indication). The median service life was 5.9 years (25th-75th percentile, 4.9-6.9) for single- and dual-chamber ICD and 4.9 years (25th-75th percentile, 4.0-5.7) for CRT-D. On multivariate analysis, the factors CRT-D device, SC/DC ICD generator from Biotronik, percentage of ventricular pacing, and the occurrence of a system failure were positively associated with a replacement procedure. By contrast, the device from Boston Scientific was an independent protective factor against replacement. Considerable differences were seen in battery duration in both ICD and CRT-D. Specifically, Biotronik devices showed the shortest longevity among ICD and Boston Scientific showed the longest longevity among CRT-D (log-rank test, P < 0.001 for pairwise comparisons). CONCLUSION: Several factors were associated with shorter service life of ICD devices: CRT-D, occurrence of system failure and percentage of ventricular pacing. Our results confirmed significant differences among manufacturers.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Remoción de Dispositivos , Cardioversión Eléctrica/instrumentación , Suministros de Energía Eléctrica , Falla de Prótesis , Anciano , Femenino , Humanos , Italia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo
16.
Europace ; 18(3): 353-8, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26443444

RESUMEN

AIMS: Right ventricular pacing adversely affects left atrial (LA) structure and function that may trigger atrial fibrillation (AF). This study compares the occurrence of persistent/permanent AF during long-term Hisian area (HA), right ventricular septal (RVS), and right ventricular apex (RVA) pacing in patients with complete/advanced atrioventricular block (AVB). METHODS AND RESULTS: We collected retrospective data from 477 consecutive patients who underwent pacemaker implantation for complete/advanced AVB. Ventricular pacing leads were located in the HA, RVS, and RVA in 148, 140, and 189 patients, respectively. The occurrence of persistent/permanent AF was observed in 114 (23.9%) patients (follow-up 58.5 ± 26.5 months). Hisian area groups presented a lower rate of AF occurrence (16.9%) compared with RVS and RVA groups (25.7 and 28.0%, respectively), P = 0.049. Cox's proportional hazard model was used to estimate HR. The risk of persistent/permanent AF was significantly lower in the patients paced from HA compared with those paced from RVA, HR = 0.28 (95% CI 0.16-0.48, P = 0.0001). The RVS and RVA pacing groups showed a similar AF risk: HR 1.04 (95% CI 0.66-1.64, P = 0.856). Other independent predictors of persistent/permanent AF occurrence included previous (before device implantation) paroxysmal AF (HR = 4.08; 95% CI 3.15-7.31, P = 0.0001), LA diameter, and age, whereas baseline bundle-branch block was associated with a lower risk of AF occurrence (HR = 0.56; 95% CI 0.35-0.81, P = 0.003). CONCLUSIONS: HA pacing compared with RVA or RVS pacing seems to be associated with a lower risk of persistent/permanent AF occurrence. The risk of persistent/permanent AF was similar in the RVA vs. RVS groups.


Asunto(s)
Fibrilación Atrial/etiología , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/efectos adversos , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Marcapaso Artificial/efectos adversos , Función Ventricular Derecha , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/prevención & control , Función del Atrio Izquierdo , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/fisiopatología , Fascículo Atrioventricular/fisiopatología , Distribución de Chi-Cuadrado , Supervivencia sin Enfermedad , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Tabique Interventricular/fisiopatología
17.
Europace ; 16(7): 1033-9, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24473501

RESUMEN

AIMS: Right ventricular apex (RVA) pacing has adverse effects on left atrial (LA) function and may contribute to atrial arrhythmias. The effects of Hisian area (HA) pacing on LA function are still lacking. The objective of this study is to assess the left ventricular (LV) electromechanical activation/relaxation, systolic (S), diastolic (D) phases, and their effects on LA function during pacing from HA and RVA. METHODS AND RESULTS: Thirty-seven patients with normal cardiac function underwent permanent HA pacing. In all patients, a RVA backup lead was added. The patients first underwent 3 months of HA pacing, followed by 3 months of RVA pacing. After each 3-month period, we compared by echocardiography: S-D LV electromechanical delay (S-D EMD), S-D intra-LV dyssynchrony, LV S-D phases, and their function evaluated by myocardial performance index (MPI) and mitral annular tissue Doppler early diastolic velocity (E'), pulmonary arterial systolic pressure (PASP), and LA function (LA phasic volumes and their emptying fraction). Right ventricular apex compared with HA pacing increased S-D EMD (P < 0.001) and intra-LV dyssynchrony (P < 0.001). As a consequence, a significant longer LV isovolumetric contraction time (P < 0.001) and LV isovolumetric relaxation time (P = 0.05) were measured during RVA compared with HA pacing, whereas LV ejection time was shorter (P = 0.033). Moreover, HA pacing resulted in significantly better MPI (P = 0.039), higher value of E' (P = 0.049), and lower PASP (P < 0.001). Finally, RVA compared with HA pacing was associated to higher LA volumes pre-atrial contraction (P = 0.001) and minimal volume (P = 0.003) with reduction in passive emptying fraction (P < 0.001) and total emptying fraction (P = 0.005). CONCLUSION: Hisian area compared with RVA pacing resulted in a more physiological LV electromechanical activation/relaxation and consequently better LA function.


Asunto(s)
Función del Atrio Izquierdo , Bloqueo Atrioventricular/terapia , Fascículo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial/métodos , Ventrículos Cardíacos/fisiopatología , Función Ventricular Izquierda , Función Ventricular Derecha , Anciano , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial/efectos adversos , Ecocardiografía Doppler en Color , Ecocardiografía Doppler de Pulso , Electrocardiografía , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Contracción Miocárdica , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología
18.
J Cardiovasc Dev Dis ; 11(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38786966

RESUMEN

Cardiac resynchronization therapy (CRT) significantly improves clinical outcomes in patients with ventricular systolic dysfunction and dyssynchrony. Biventricular pacing (BVP) has a class IA recommendation for patients with symptomatic heart failure with reduced ejection fraction (HFrEF) and left bundle branch block (LBBB). However, approximately 30% of patients have a poor therapeutic response and do not achieve real clinical benefit. Pre-implant imaging, together with tailored programming and dedicated device algorithms, have been proposed as possible tools to improve success rate but have shown inconsistent results. Over the last few years, conduction system pacing (CSP) is becoming a real and attractive alternative to standard BVP as it can restore narrow QRS in patients with bundle branch block (BBB) by stimulating and recruiting the cardiac conduction system, thus ensuring true resynchronization. It includes His bundle pacing (HBP) and left bundle branch area pacing (LBBAP). Preliminary data coming from small single-center experiences are very promising and have laid the basis for currently ongoing randomized controlled trials comparing CSP with BVP. The purpose of this review is to delve into the emerging role of CSP as an alternative method of achieving CRT. After framing CSP in a historical perspective, the pathophysiological rationale and available clinical evidence will be examined, and crucial technical aspects will be discussed. Finally, evidence gaps and future perspectives on CSP as a technique of choice to deliver CRT will be summarized.

19.
J Interv Card Electrophysiol ; 67(1): 175-182, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37365481

RESUMEN

BACKGROUND: The Medtronic SelectSecure Model 3830 lumenless lead (Medtronic, Inc., Minneapolis, MN) is commonly used for conduction system pacing (CSP). However, with this increased use, the potential need for transvenous lead extraction (TLE) also will increase. While extraction of endocardial 3830 leads is rather well described especially in pediatric and adult congenital heart disease population, there is very limited data on extraction of CSP leads. In the present study, we reported our preliminary experience on TLE of CSP leads and provided technical considerations. METHODS: The study population comprised 6 consecutive patients (67% male; mean age 70 ± 22 years) with CSP leads (3830 leads), including left bundle branch pacing (LBBP) lead (n = 3) and His pacing lead (n = 3) undergoing TLE. Overall target leads were 17. The mean implant duration time of CSP leads was 97 ± 90 months [range 8-193). RESULTS: Manual traction was successful in 2 cases and mechanical extraction tools were required in the remaining cases. Sixteen leads (94%) were completely extracted, whereas incomplete removal was observed in one lead (6%) among 1 patient. Of note, in the only lead incompletely removed, we observed retention of < 1-cm remnant of lead material consisting of the screw of 3830 LBBP lead into the interventricular septum. No failure of lead extraction was reported and no major complications occurred. CONCLUSIONS: Our findings demonstrated that at an experienced center the success of TLE of chronically implanted CSP leads is high in the absence of major complications also when mechanical extraction tools are needed.


Asunto(s)
Cardiopatías Congénitas , Marcapaso Artificial , Humanos , Masculino , Adulto , Niño , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Estudios Retrospectivos , Remoción de Dispositivos , Cardiopatías Congénitas/cirugía , Estimulación Cardíaca Artificial , Trastorno del Sistema de Conducción Cardíaco
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA