Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Clin Chem ; 69(2): 160-167, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36576352

RESUMEN

BACKGROUND: Fetal fraction (FF) measurement is considered important for reliable noninvasive prenatal testing (NIPT). Using minimal FF threshold as a quality parameter is under debate. We evaluated the variability in reported FFs of individual samples between providers and laboratories and within a single laboratory. METHODS: Genomic quality assessment and European Molecular Genetics Quality Network provide joint proficiency testing for NIPT. We compared reported FFs across all laboratories and stratified according to test methodologies. A single sample was sequenced repeatedly and FF estimated by 2 bioinformatics methods: Veriseq2 and SeqFF. Finally, we compared FFs by Veriseq and SeqFF in 87 351 NIPT samples. RESULTS: For each proficiency test sample we observed a large variability in reported FF, SDs and CVs ranging from 1.7 to 3.6 and 17.0 to 35.8, respectively. FF measurements reported by single nucleotide polymorphism-based methods had smaller SDs (0.5 to 2.4) compared to whole genome sequencing-based methods (1.8 to 2.9). In the internal quality assessment, SDs were similar between SeqFF (SD 1.0) and Veriseq v2 (SD 0.9), but mean FF by Veriseq v2 was higher compared to SeqFF (9.0 vs 6.4, P 0.001). In patient samples, reported FFs were on average 1.12-points higher in Veriseq than in SeqFF (P 0.001). CONCLUSIONS: Current methods do not allow for a reliable and consistent FF estimation. Our data show estimated FF should be regarded as a laboratory-specific range, rather than a precise number. Applying strict universal minimum thresholds might result in unnecessary test failures and should be used with caution.


Asunto(s)
Pruebas Prenatales no Invasivas , Embarazo , Femenino , Humanos , Atención Prenatal , Feto , Genómica , Genoma , Diagnóstico Prenatal/métodos , Aneuploidia
2.
BMC Cancer ; 22(1): 759, 2022 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-35820813

RESUMEN

BACKGROUND: Circulating cell free DNA (cfDNA) testing of plasma for EGFR somatic variants in lung cancer patients is being widely implemented and with any new service, external quality assessment (EQA) is required to ensure patient safety. An international consortium, International Quality Network for Pathology (IQNPath), has delivered a second round of assessment to measure the accuracy of cfDNA testing for lung cancer and the interpretation of the results. METHODS: A collaboration of five EQA provider organisations, all members of IQNPath, have delivered the assessment during 2018-19 to a total of 264 laboratories from 45 countries. Bespoke plasma reference material containing a range of EGFR mutations at varying allelic frequencies were supplied to laboratories for testing and reporting according to routine procedures. The genotyping accuracy and clinical reporting was reviewed against standardised criteria and feedback was provided to participants. RESULTS: The overall genotyping error rate in the EQA was found to be 11.1%. Low allelic frequency samples were the most challenging and were not detected by some testing methods, resulting in critical genotyping errors. This was reflected in higher false negative rates for samples with variant allele frequencies (VAF) rates less than 1.5% compared to higher frequencies. A sample with two different EGFR mutations gave inconsistent detection of both mutations. However, for one sample, where two variants were present at a VAF of less than 1% then both mutations were correctly detected in 145/263 laboratories. Reports often did not address the risk that tumour DNA may have not been tested and limitations of the methodologies provided by participants were insufficient. This was reflected in the average interpretation score for the EQA being 1.49 out of a maximum of 2. CONCLUSIONS: The variability in the standard of genotyping and reporting highlighted the need for EQA and educational guidance in this field to ensure the delivery of high-quality clinical services where testing of cfDNA is the only option for clinical management.


Asunto(s)
Ácidos Nucleicos Libres de Células , Neoplasias Pulmonares , Receptores ErbB/genética , Frecuencia de los Genes , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/genética , Mutación
3.
Clin Chem Lab Med ; 60(6): 821-829, 2022 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-35218176

RESUMEN

Disruptive imaging and laboratory technologies can improve clinical decision processes and outcomes in oncology. However, certain obstacles must be overcome before these technologies can be fully implemented as part of the standard for care. An integrative diagnostic approach represents a unique opportunity to unleash the full diagnostic potential and paves the way towards personalized cancer diagnostics. To meet this demand, an interdisciplinary Task Force of the EFLM was initiated as a consequence of an EFLM/ESR during the CELME 2019 meeting in order to evaluate the clinical value of CNAPS/CTC (circulating nucleic acids in plasma and serum/circulating tumor cells) in early detection of cancer. Here, an overview of current disruptive techniques, their clinical implications and potential value of an integrative diagnostic approach is provided. Furthermore, requirements such as the establishment of diagnostic tumor boards, development of adequate software solutions and a change of mindset towards a new generation of diagnosticians providing actionable health information are presented. This development has the potential to elevate the position and clinical recognition of diagnosticians.


Asunto(s)
Detección Precoz del Cáncer , Células Neoplásicas Circulantes , Biomarcadores de Tumor , Humanos , Células Neoplásicas Circulantes/patología
4.
Prenat Diagn ; 39(5): 379-387, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30767256

RESUMEN

OBJECTIVE: To ensure accurate and appropriate reporting of non-invasive prenatal testing (NIPT) results, the standard of testing should be measured and monitored by participation in external quality assessment (EQA) schemes. The findings from international pilot EQAs for NIPT for the common trisomies are presented. METHODS: In the first pilot, three EQA providers used artificially manufactured reference materials to deliver an EQA for NIPT. The second pilot used clinically collected maternal plasma samples. The testing and reporting for aneuploidy status was performed by participating laboratories using routine procedures. Reports were assessed against peer ratified criteria and EQA scores were returned to participants. RESULTS: Forty laboratories participated in the first. Genotyping accuracy was high; four laboratories reported a critical genotyping error (10%) and two reported partial results. Eighty seven laboratories participated in the second pilot using maternal plasma, two reporting a critical genotyping error (2.3%). For both rounds, report content was variable with key information frequently omitted or difficult to identify within the report. CONCLUSIONS: We have successfully delivered an international pilot EQA for NIPT. When compared with currently available manufactured materials, EQA for NIPT was best performed using clinically collected maternal plasma. Work is required to define and improve the standard of reporting.


Asunto(s)
Pruebas Prenatales no Invasivas/normas , Femenino , Humanos , Internacionalidad , Embarazo , Garantía de la Calidad de Atención de Salud
5.
BMC Cancer ; 18(1): 804, 2018 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-30092778

RESUMEN

BACKGROUND: Molecular analysis of circulating tumour DNA (ctDNA) is becoming increasingly important in clinical treatment decisions. A pilot External Quality Assessment (EQA) scheme for ctDNA analysis was organized by four European EQA providers under the umbrella organization IQN Path, in order to investigate the feasibility of delivering an EQA to assess the detection of clinically relevant variants in plasma circulating cell-free DNA (cfDNA) and to analyze reporting formats. METHODS: Thirty-two experienced laboratories received 5 samples for EGFR mutation analysis and/or 5 samples for KRAS and NRAS mutation analysis. Samples were artificially manufactured to contain 3 mL of human plasma with 20 ng/mL of fragmented ctDNA and variants at allelic frequencies of 1 and 5%. RESULTS: The scheme error rate was 20.1%. Higher error rates were observed for RAS testing when compared to EGFR analysis, for allelic frequencies of 1% compared to 5%, and for cases including 2 different variants. The reports over-interpreted wild-type results and frequently failed to comment on the amount of cfDNA extracted. CONCLUSIONS: The pilot scheme demonstrated the feasibility of delivering a ctDNA EQA scheme and the need for such a scheme due to high error rates in detecting low frequency clinically relevant variants. Recommendations to improve reporting of cfDNA are provided.


Asunto(s)
Ácidos Nucleicos Libres de Células/sangre , ADN Tumoral Circulante/sangre , Neoplasias/sangre , Garantía de la Calidad de Atención de Salud , Receptores ErbB/sangre , Humanos , Mutación , Neoplasias/patología , Proteínas Proto-Oncogénicas p21(ras)/sangre
6.
Clin Chem Lab Med ; 56(2): 220-228, 2018 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-28841569

RESUMEN

BACKGROUND: Circulating tumour DNA (ctDNA) is considered to have a high potential for future management of malignancies. This pilot external quality assessment (EQA) scheme aimed to address issues of analytical quality in this new area of laboratory diagnostics. METHODS: The EQA scheme consisted of three 2-mL EDTA-plasma samples spiked with fragmented genomic DNA with a mutant allele frequency ranging from 0% to 10% dedicated to the analysis of nine known sequence variations in KRAS codon 12/13 and of BRAF V600E. Laboratories reported: (1) time elapsed for processing, (2) storage temperatures, (3) methods for extraction and quantification, (4) genotyping methodologies and (5) results. RESULTS: Specimens were sent to 42 laboratories from 10 European countries; 72.3% reported to isolate cell-free DNA (cfDNA) manually, 62.5% used the entire plasma volume for cfDNA isolation and 38.5% used >10% of cfDNA extracted for downstream genotyping. Of the methods used for quantification, PicoGreen demonstrated the lowest coefficient of variation (33.7%). For genotyping, 11 different methods were reported with the highest error rate observed for Sanger sequencing and the lowest for highly sensitive approaches like digital PCR. In total, 197 genotypes were determined with an overall error rate of 6.09%. CONCLUSIONS: This pilot EQA scheme illustrates the current variability in multiple phases of cfDNA processing and analysis of ctDNA resulting in an overall error rate of 6.09%. The areas with the greatest variance and clinical impact included specimen volume, cfDNA quantification method, and preference of genotyping platform. Regarding quality assurance, there is an urgent need for harmonisation of procedures and workflows.


Asunto(s)
Técnicas de Química Analítica/normas , ADN Tumoral Circulante/análisis , ADN Tumoral Circulante/aislamiento & purificación , Técnicas de Genotipaje/normas , Técnicas de Química Analítica/métodos , Técnicas de Genotipaje/métodos , Humanos , Biopsia Líquida , Volumen Plasmático , Manejo de Especímenes , Flujo de Trabajo
7.
Hum Mutat ; 38(8): 912-921, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28471515

RESUMEN

Next-generation sequencing is radically changing how DNA diagnostic laboratories operate. What started as a single-gene profession is now developing into gene panel sequencing and whole-exome and whole-genome sequencing (WES/WGS) analyses. With further advances in sequencing technology and concomitant price reductions, WGS will soon become the standard and be routinely offered. Here, we focus on the critical steps involved in performing WGS, with a particular emphasis on points where WGS differs from WES, the important variables that should be taken into account, and the quality control measures that can be taken to monitor the process. The points discussed here, combined with recent publications on guidelines for reporting variants, will facilitate the routine implementation of WGS into a diagnostic setting.


Asunto(s)
Genoma Humano/genética , Exoma/genética , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Proteína 2 de Unión a Metil-CpG/genética , Polimorfismo de Nucleótido Simple/genética
8.
Br J Cancer ; 117(5): 710-716, 2017 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-28751759

RESUMEN

BACKGROUND: Thousands of clinically relevant variations in BRCA1 and BRCA2 have been discovered and this poses a significant challenge with respect to the accurate detection, analysis turn-around time, characterisation and interpretation of these sequence variants. METHODS: We evaluated the performance of different BRCA1/2 gene testing practices in routine diagnostic use in 20 European laboratories, with a focus on next-generation sequencing-based strategies as this is the technical approach implemented by or under adoption by most European clinical laboratories. Participant laboratories, selected on expertise and diagnostic service quality, tested 10 identical DNA samples containing a range of challenging pathogenic variants. RESULTS: A small number of errors in the detection of pathogenic and significant variants were identified (2.6% diagnostic error rate). There was a high degree of concordance (>97%) across all laboratories for all variants detected. No systematic technical flaw was identified in the strategies employed across the participating laboratories. CONCLUSIONS: The discrepancies identified are most likely due to human error or the way the methodology has been implemented locally, for example, next-generation sequencing bioinformatics pipelines, rather than technical limitations of the methods. The choice of BRCA1/2 testing method will therefore depend on multiple factors including required throughput and turn-around times, access to equipment, expertise and budget.


Asunto(s)
Análisis Mutacional de ADN/métodos , Genes BRCA1 , Genes BRCA2 , Pruebas Genéticas/métodos , Ensayos de Aptitud de Laboratorios , Servicios de Laboratorio Clínico , Técnicas de Laboratorio Clínico/normas , Biología Computacional/métodos , Europa (Continente) , Reacciones Falso Negativas , Reacciones Falso Positivas , Genotipo , Mutación de Línea Germinal , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos
9.
Prenat Diagn ; 37(7): 699-704, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28497584

RESUMEN

OBJECTIVE: Non-invasive prenatal testing (NIPT) for trisomies 13, 18 and 21 is used worldwide. Laboratory reports should provide clear, concise results with test limitations indicated, yet no national or local guidelines are currently available. Here, we aim to present minimum best practice guidelines. METHODS: All laboratories registered in the three European quality assurance schemes for molecular and cytogenetics were invited to complete an online survey focused on services provided for NIPT and non-invasive prenatal diagnosis. Laboratories delivering NIPT for aneuploidy were asked to submit two example reports; one high and one low risk result. Reports were reviewed for content and discussed at a meeting of laboratory providers and clinicians held at the ISPD 2016 conference in Berlin. RESULTS: Of the 122 laboratories that responded, 50 issued reports for NIPT and 43 of these submitted sample reports. Responses and reports were discussed by 72 attendees at the meeting. Consensus opinion was determined in several areas and used to develop best practice guidelines for reporting of NIPT results. CONCLUSIONS: Across Europe, there is considerable variation in reporting NIPT results. Here, we describe minimum best practice guidelines, which will be distributed to European laboratories, and reports audited in subsequent external quality assurance cycles. © 2017 The Authors. Prenatal Diagnosis published by John Wiley & Sons, Ltd.


Asunto(s)
Pruebas de Detección del Suero Materno/normas , Trisomía , Europa (Continente) , Femenino , Humanos , Embarazo
10.
Hum Mutat ; 37(6): 570-5, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26920083

RESUMEN

The Human Genome Variation Society (HGVS) recommendations provide standardized nomenclature for reporting variants. This should be encouraged in molecular pathology-both for issuing diagnostic reports and for correct data recording in electronic databases. Many providers of external quality assessment (EQA) promote the correct use of HGVS nomenclature by scoring variant descriptions used in EQA reports. This study focuses on the type and impact of variant nomenclature errors. An assessment was made of EGFR gene variant nomenclature by four EQA providers (European Society of Pathology [ESP], European Molecular Genetics Quality Network [EMQN], United Kingdom National External Quality Assessment Service for Molecular Genetics, and the French national Gen&Tiss EQA scheme) for two EQA distributions. Laboratories testing for oncology biomarkers make different errors when describing EGFR gene variants. Significant differences were observed regarding inclusion of the correct reference sequence: EMQN participants made fewer errors compared to ESP EQA participants (P-value = 0.015). The analysis of ESP EQA participants showed significant improvement over 2 years (P-value = 0.016). Results demonstrate the need for improvement of variant reporting according to HGVS guidelines. Consequences of using incorrect mutation nomenclature are currently perceived as low by many laboratories, but the impact will rise with an increased reliance on databases to assist in result analysis.


Asunto(s)
Bases de Datos Factuales/normas , Terminología como Asunto , Receptores ErbB/genética , Guías como Asunto , Proyecto Genoma Humano/organización & administración , Humanos , Mutación , Control de Calidad
11.
Virchows Arch ; 482(2): 347-355, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36355212

RESUMEN

Tumor mutational burden (TMB) has recently been approved as an agnostic biomarker for immune checkpoint inhibitors. However, methods for TMB testing have not yet been standardized. The International Quality Network for Pathology (IQNPath) organized a pilot external quality assessment (EQA) scheme for TMB testing. The aim of this program was the validation of the materials and the procedures for the EQA of this complex biomarker. Five formalin-fixed paraffin-embedded (FFPE) cell lines were selected to mimic the various TMB values observed in clinical practice. The FFPE samples were tested with the FoundationOne CDx (F1CDx) assay as the reference test and three commercially available targeted sequencing panels. Following this internal validation, the five cell lines were sent to 29 laboratories selected on the basis of a previous survey. Nineteen of the 23 laboratories that submitted results (82.6%) used targeted sequencing for TMB estimation. Only two laboratories performed whole exome sequencing (WES) and two assessed TMB by clinical exome. A high variability in the reported TMB values was observed. The variability was higher for samples with the highest TMB value according to the F1CDx test. However, good reproducibility of the TMB score was shown by laboratories using the same panel. The majority of laboratories did not indicate a TMB cut-off value for clinical interpretation. In conclusion, this pilot EQA scheme suggests that it is feasible to run such an EQA program for TMB assessment. However, the results of our pilot highlight the numerous challenges for the standardization of this test.


Asunto(s)
Biomarcadores de Tumor , Neoplasias , Humanos , Reproducibilidad de los Resultados , Estudios de Factibilidad , Mutación , Biomarcadores de Tumor/genética , Neoplasias/diagnóstico , Neoplasias/genética , Neoplasias/patología , Carga Tumoral
12.
Virchows Arch ; 2023 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-37202567

RESUMEN

Demand for large-scale tumour profiling across cancer types has increased in recent years, driven by the emergence of targeted drug therapies. Analysing alternations in plasma circulating tumour DNA (ctDNA) for cancer detection can improve survival; ctDNA testing is recommended when tumour tissue is unavailable. An online survey of molecular pathology testing was circulated by six external quality assessment members of IQN Path to registered laboratories and all IQN Path collaborative corporate members. Data from 275 laboratories across 45 countries were collected; 245 (89%) perform molecular pathology testing, including 177 (64%) which perform plasma ctDNA diagnostic service testing. The most common tests were next-generation sequencing-based (n = 113). Genes with known stratified treatment options, including KRAS (n = 97), NRAS (n = 84), and EGFR (n = 130), were common targets. The uptake of ctDNA plasma testing and plans to implement further testing demonstrates the importance of support from a well-designed EQA scheme.

13.
Virchows Arch ; 481(3): 335-350, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35857102

RESUMEN

Biomarker testing is crucial for treatment selection in advanced non-small cell lung cancer (NSCLC). However, the quantity of available tissue often presents a key constraint for patients with advanced disease, where minimally invasive tissue biopsy typically returns small samples. In Part 1 of this two-part series, we summarise evidence-based recommendations relating to small sample processing for patients with NSCLC. Generally, tissue biopsy techniques that deliver the greatest quantity and quality of tissue with the least risk to the patient should be selected. Rapid on-site evaluation can help to ensure sufficient sample quality and quantity. Sample processing should be managed according to biomarker testing requirements, because tissue fixation methodology influences downstream nucleic acid, protein and morphological analyses. Accordingly, 10% neutral buffered formalin is recommended as an appropriate fixative, and the duration of fixation is recommended not to exceed 24-48 h. Tissue sparing techniques, including the 'one biopsy per block' approach and small sample cutting protocols, can help preserve tissue. Cytological material (formalin-fixed paraffin-embedded [FFPE] cytology blocks and non-FFPE samples such as smears and touch preparations) can be an excellent source of nucleic acid, providing either primary or supplementary patient material to complete morphological and molecular diagnoses. Considerations on biomarker testing, reporting and quality assessment are discussed in Part 2.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Ácidos Nucleicos , Biomarcadores , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Carcinoma de Pulmón de Células no Pequeñas/patología , Testimonio de Experto , Fijadores , Formaldehído , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patología , Adhesión en Parafina , Fijación del Tejido/métodos
14.
Virchows Arch ; 481(3): 351-366, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35857103

RESUMEN

The diagnostic work-up for non-small cell lung cancer (NSCLC) requires biomarker testing to guide therapy choices. This article is the second of a two-part series. In Part 1, we summarised evidence-based recommendations for obtaining and processing small specimen samples (i.e. pre-analytical steps) from patients with advanced NSCLC. Here, in Part 2, we summarise evidence-based recommendations relating to analytical steps of biomarker testing (and associated reporting and quality assessment) of small specimen samples in NSCLC. As the number of biomarkers for actionable (genetic) targets and approved targeted therapies continues to increase, simultaneous testing of multiple actionable oncogenic drivers using next-generation sequencing (NGS) becomes imperative, as set forth in European Society for Medical Oncology guidelines. This is particularly relevant in advanced NSCLC, where tissue specimens are typically limited and NGS may help avoid tissue exhaustion compared with sequential biomarker testing. Despite guideline recommendations, significant discrepancies in access to NGS persist across Europe, primarily due to reimbursement constraints. The use of increasingly complex testing methods also has implications for the reporting of results. Molecular testing reports should include clinical interpretation with additional commentary on sample adequacy as appropriate. Molecular tumour boards are recommended to facilitate the interpretation of complex genetic information arising from NGS, and to collaboratively determine the optimal treatment for patients with NSCLC. Finally, whichever testing modality is employed, it is essential that adequate internal and external validation and quality control measures are implemented.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Biomarcadores , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Carcinoma de Pulmón de Células no Pequeñas/genética , Carcinoma de Pulmón de Células no Pequeñas/patología , Testimonio de Experto , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/tratamiento farmacológico , Neoplasias Pulmonares/genética , Mutación
15.
Eur J Cancer ; 176: 70-77, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36194905

RESUMEN

BACKGROUND: Predictive biomarkers are essential for selecting the best therapeutic strategy in patients with cancer. The International Quality Network for Pathology, the European Cancer Patient Coalition and the European Federation of Pharmaceuticals Industries and Associations evaluated the access to and quality of biomarker testing across Europe. METHODS: Data sources included surveys of 141 laboratory managers and 1.665 patients, and 58 in-depth interviews with laboratory managers, physicians and payers. Four access metrics (laboratory access, test availability, test reimbursement, test order rate) and three quality metrics (quality scheme participation, laboratory accreditation, test turnaround time) were applied to rank the results. RESULTS: The access to precision medicines is higher in countries with public national reimbursement processes in place. Lack of diagnostic laboratory infrastructure, inefficient organization and/or insufficient public reimbursement narrow the access to single biomarker tests in many European countries. In countries with limited public reimbursement, pharma and patients' out of pocket were the primary funding sources for testing. Uptake of multi-biomarker next generation sequencing (NGS) is highly varied, ranging from 0% to >50%. Financial constraints, a lack of NGS testing capabilities and the failure to include NGS testing in the guidelines represent the main barriers to NGS implementation. The quality of biomarker testing is highest in Western and Northern Europe, with more than 90% of laboratories participating in quality assurance schemes. CONCLUSIONS: Our data clearly indicate the need for a call to action to ensure the clinical implementation of precision medicine in Europe.


Asunto(s)
Neoplasias , Humanos , Neoplasias/diagnóstico , Neoplasias/genética , Medicina de Precisión , Oncología Médica , Europa (Continente) , Biomarcadores
16.
Female Pelvic Med Reconstr Surg ; 27(4): 217-222, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33315626

RESUMEN

ABSTRACT: Historically, our health care system has been based on a fee-for-service model, which has resulted in high-cost and fragmented care. The Center for Medicare & Medicaid Services is moving toward a paradigm in which health care providers are incentivized to provide cost-effective, coordinated, value-based care in an effort to control costs and ensure high-quality care for all patients. In 2015, the Medicare Access and Children's Health Insurance Program Reauthorization Act repealed the Sustainable Growth Rate and the fee-for-service model, replacing them with a 2-track system: Merit-based Incentive Payment System and the advanced Alternative Payment Model (aAPM) system. In 2016, the American Urogynecologic Society Payment Reform Committee was created and tasked with developing aAPMs for pelvic floor disorders. The purpose of this article is to describe the stress urinary incontinence aAPM framework, the data selected and associated data plan, and some of the challenges considered and encountered during the aAPM development.


Asunto(s)
Modelos Económicos , Mecanismo de Reembolso , Incontinencia Urinaria de Esfuerzo/economía , Incontinencia Urinaria de Esfuerzo/terapia , Femenino , Humanos , Medicare , Estados Unidos
17.
Virchows Arch ; 479(6): 1067-1072, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33856555

RESUMEN

While tumour mutation burden (TMB) is emerging as a possible biomarker for immune-checkpoint inhibitors (ICI), methods for testing have not been standardised as yet. In April 2019, the International Quality Network for Pathology (IQN Path) launched a survey to assess the current practice of TMB testing. Of the 127 laboratories that replied, 69 (54.3%) had already introduced TMB analysis for research purposes and/or clinical applications. Fifty laboratories (72.5%) used targeted sequencing, although a number of different panels were employed. Most laboratories tested formalin-fixed paraffin-embedded material (94.2%), while 18/69 (26%) tested also cell-free DNA. Fifty-five laboratories used both single nucleotide variants and indels for TMB calculation; 20 centers included only non-synonymous variants. In conclusion, the data from this survey indicate that multiple global laboratories were capable of rapidly introducing routine clinical TMB testing. However, the variability of testing methods raises concerns about the reproducibility of results among centers.


Asunto(s)
Biomarcadores de Tumor/genética , Análisis Mutacional de ADN , Secuenciación de Nucleótidos de Alto Rendimiento , Mutación INDEL , Neoplasias/genética , Polimorfismo de Nucleótido Simple , Australia , Canadá , Toma de Decisiones Clínicas , Europa (Continente) , Encuestas de Atención de la Salud , Humanos , Inhibidores de Puntos de Control Inmunológico/uso terapéutico , Ensayos de Aptitud de Laboratorios , Neoplasias/tratamiento farmacológico , Neoplasias/patología , Variaciones Dependientes del Observador , Medicina de Precisión , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
18.
Eur J Hum Genet ; 28(5): 558-566, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32055015

RESUMEN

Modern diagnostic methods (next-generation sequencing) are one of the current hopes with regard to a personalised medicine. By applying detailed genetic analysis, it is possible to not only improve the prediction of potential risks (as, e.g., concerning hereditary breast cancer) but also the precision of therapy by targeting it to a specific genetic variant. However, there is no international standard for creating, structuring and/or transferring the results of a genetic test report. This type of test report often contains large amounts of complex information, and a standardised and consistent structure would offer potential benefits to all. These include reduced expenditure of time (due to the elimination of information-conversion steps), improved safety (due to a reduction in the occurrence of transmission errors, misunderstanding or misinterpretation of content) and improved clinical information gathering (by the respective linkage to scientific data and literature). Especially in regard to secondary use, a standardised (electronic) format would improve the suitability of these data in retrospective studies and basic research. In this study, we analysed the format and content of 96 genetic testing reports (germline and somatic) from Germany, Switzerland and Austria. Based on these results, we summarised and discussed potentially critical data that were demonstrated to be reported inconsistently, and propose a baseline structure for reporting that would also ease future electronic conversion.


Asunto(s)
Registros Electrónicos de Salud/normas , Pruebas Genéticas/normas , Austria , Pruebas Genéticas/métodos , Alemania , Humanos , Reportes Públicos de Datos en Atención de Salud , Suiza
19.
J Mol Diagn ; 22(6): 736-747, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32205291

RESUMEN

Liquid biopsies have emerged as a useful addition to tissue biopsies in molecular pathology. Literature has shown lower laboratory performances when a new method of variant analysis is introduced. This study evaluated the differences in variant analysis between tissue and plasma samples after the introduction of liquid biopsy in molecular analysis. Data from a pilot external quality assessment scheme for the detection of molecular variants in plasma samples and from external quality assessment schemes for the detection of molecular variants in tissue samples were collected. Laboratory performance and error rates by sample were compared between matrices for variants present in both scheme types. Results showed lower overall performance [65.6% (n = 276) versus 89.2% (n = 1607)] and higher error rates [21.0% to 43.5% (n = 138) versus 8.7% to 16.7% (n = 234 to 689)] for the detection of variants in plasma compared to tissue, respectively. In the plasma samples, performance was decreased for variants with an allele frequency of 1% compared to 5% [56.5% (n = 138) versus 74.6% (n = 138)]. The implementation of liquid biopsy in the detection of circulating tumor DNA in plasma was associated with poor laboratory performance. It is important both to apply optimal detection methods and to extensively validate new methods for testing circulating tumor DNA before treatment decisions are made.


Asunto(s)
ADN Tumoral Circulante/sangre , Fijadores/farmacología , Formaldehído/farmacología , Neoplasias/sangre , Neoplasias/diagnóstico , Adhesión en Parafina/métodos , Fijación del Tejido/métodos , Biomarcadores de Tumor/sangre , ADN Tumoral Circulante/genética , Frecuencia de los Genes , Humanos , Biopsia Líquida , Oncología Médica/métodos , Mutación , Neoplasias/patología , Datos Preliminares
20.
Eur J Hum Genet ; 28(2): 202-212, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31570784

RESUMEN

Next-generation sequencing (NGS) is replacing other molecular techniques to become the de facto gene diagnostics approach, transforming the speed of diagnosis for patients and expanding opportunities for precision medicine. Consequently, for accredited laboratories as well as those seeking accreditation, both objective measures of quality and external review of laboratory processes are required. External quality assessment (EQA), or Proficiency Testing (PT), can assess a laboratory's service through an independent external agency, the EQA provider. The analysis of a growing number of genes and whole exome and genomes is now routine; therefore, an EQA must be delivered to enable all testing laboratories to participate. In this paper, we describe the development of a unique platform and gene target independent EQA scheme for NGS, designed to scale from current to future requirements of clinical diagnostic laboratories testing for germline and somatic variants. The EQA results from three annual rounds indicate that clinical diagnostic laboratories are providing an increasingly high-quality NGS service and variant calling abilities are improving. From an EQA provider perspective, challenges remain regarding delivery and performance criteria, as well as in analysing similar NGS approaches between cohorts with meaningful metrics, sample sourcing and data formats.


Asunto(s)
Pruebas Genéticas/normas , Mutación de Línea Germinal , Secuenciación de Nucleótidos de Alto Rendimiento/normas , Neoplasias/genética , Garantía de la Calidad de Atención de Salud/métodos , Análisis de Secuencia de ADN/normas , Algoritmos , Humanos , Neoplasias/diagnóstico , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA