Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Proc Natl Acad Sci U S A ; 120(31): e2303928120, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37494398

RESUMEN

Although sensor technologies have allowed us to outperform the human senses of sight, hearing, and touch, the development of artificial noses is significantly behind their biological counterparts. This largely stems from the sophistication of natural olfaction, which relies on both fluid dynamics within the nasal anatomy and the response patterns of hundreds to thousands of unique molecular-scale receptors. We designed a sensing approach to identify volatiles inspired by the fluid dynamics of the nose, allowing us to extract information from a single sensor (here, the reflectance spectra from a mesoporous one-dimensional photonic crystal) rather than relying on a large sensor array. By accentuating differences in the nonequilibrium mass-transport dynamics of vapors and training a machine learning algorithm on the sensor output, we clearly identified polar and nonpolar volatile compounds, determined the mixing ratios of binary mixtures, and accurately predicted the boiling point, flash point, vapor pressure, and viscosity of a number of volatile liquids, including several that had not been used for training the model. We further implemented a bioinspired active sniffing approach, in which the analyte delivery was performed in well-controlled 'inhale-exhale' sequences, enabling an additional modality of differentiation and reducing the duration of data collection and analysis to seconds. Our results outline a strategy to build accurate and rapid artificial noses for volatile compounds that can provide useful information such as the composition and physical properties of chemicals, and can be applied in a variety of fields, including disease diagnosis, hazardous waste management, and healthy building monitoring.


Asunto(s)
Nariz , Olfato , Humanos , Nariz Electrónica , Aprendizaje Automático , Gases
2.
Sci Transl Med ; 15(690): eadd9779, 2023 04 05.
Artículo en Inglés | MEDLINE | ID: mdl-37018418

RESUMEN

Implantable tubes, shunts, and other medical conduits are crucial for treating a wide range of conditions from ears and eyes to brain and liver but often impose serious risks of device infection, obstruction, migration, unreliable function, and tissue damage. Efforts to alleviate these complications remain at an impasse because of fundamentally conflicting design requirements: Millimeter-scale size is required to minimize invasiveness but exacerbates occlusion and malfunction. Here, we present a rational design strategy that reconciles these trade-offs in an implantable tube that is even smaller than the current standard of care. Using tympanostomy tubes (ear tubes) as an exemplary case, we developed an iterative screening algorithm and show how unique curved lumen geometries of the liquid-infused conduit can be designed to co-optimize drug delivery, effusion drainage, water resistance, and biocontamination/ingrowth prevention in a single subcapillary-length-scale device. Through extensive in vitro studies, we demonstrate that the engineered tubes enabled selective uni- and bidirectional fluid transport; nearly eliminated adhesion and growth of common pathogenic bacteria, blood, and cells; and prevented tissue ingrowth. The engineered tubes also enabled complete eardrum healing and hearing preservation and exhibited more efficient and rapid antibiotic delivery to the middle ear in healthy chinchillas compared with current tympanostomy tubes, without resulting in ototoxicity at up to 24 weeks. The design principle and optimization algorithm presented here may enable tubes to be customized for a wide range of patient needs.


Asunto(s)
Otitis Media con Derrame , Humanos , Otitis Media con Derrame/diagnóstico , Ventilación del Oído Medio/métodos , Oído Medio/patología , Prótesis e Implantes , Antibacterianos
3.
Biotechnol Adv ; 34(3): 250-71, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26485407

RESUMEN

Analyte-sensitive hydrogels that incorporate optical structures have emerged as sensing platforms for point-of-care diagnostics. The optical properties of the hydrogel sensors can be rationally designed and fabricated through self-assembly, microfabrication or laser writing. The advantages of photonic hydrogel sensors over conventional assay formats include label-free, quantitative, reusable, and continuous measurement capability that can be integrated with equipment-free text or image display. This Review explains the operation principles of photonic hydrogel sensors, presents syntheses of stimuli-responsive polymers, and provides an overview of qualitative and quantitative readout technologies. Applications in clinical samples are discussed, and potential future directions are identified.


Asunto(s)
Hidrogeles , Fotones , Diseño de Equipo , Sistemas de Atención de Punto
4.
ACS Appl Mater Interfaces ; 5(5): 1575-82, 2013 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-23286349

RESUMEN

Infrared (IR) sensors employing optical readout represent a promising class of devices for the development of thermographic imagers. We demonstrate an infrared radiation detection principle based on thermally tunable one-dimensional (1D) photonic crystals acting as optical filters, integrated with organic and inorganic light emitting diodes (OLEDs and LEDs, respectively). The optical filters are composed of periodically assembled mesoporous TiO2 and SiO2 layers. Due to the thermal tunability of the transmission spectrum of the optical filter, the intensity of light passing through the filter is modulated by temperature. The tuned spectrum lies in the visible region and, therefore, can be directly detected by a visible-light photodetector. The thermal response of the luminance of the OLED-photonic crystal ensemble is 3.8 cd m(-2) K(-1). Furthermore, we demonstrate that the local temperature profile can be time and spatially resolved with a resolution of 530 by 530 pixel, thus enabling a potential application as an infrared imaging sensor featuring low power consumption and low fabrication costs.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA