Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Neurophysiol ; 119(3): 1235-1247, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-29357460

RESUMEN

Response adaptation is the change of the firing rate of neurons induced by a preceding stimulus. It can be found in many sensory systems and throughout the auditory pathway. We investigated response adaptation in the external nucleus of the inferior colliculus (ICX) of barn owls ( Tyto furcata), a nocturnal bird of prey and specialist in sound localization. Individual neurons in the ICX represent locations in auditory space by maximally responding to combinations of interaural time and level differences (ITD and ILD). Neuronal responses were recorded extracellularly under ketamine-diazepam anesthesia. Response adaptation was observed in three double stimulation paradigms. In two paradigms, the same binaural parameters for both stimuli were chosen. A variation of the level of the second stimulus yielded a level increase sufficient to compensate for adaptation around 5 dB. Introducing a silent interstimulus interval (ISI) resulted in recovery from adaptation. The time course of recovery was followed by varying the ISI, and full recovery was found after an ISI of 50 ms. In a third paradigm, the ITD of the second stimulus was varied to investigate the representation of ITD under adaptive conditions. We found that adaptation led to an increased precision and improved selectivity while the best ITD was stable. These changes of representation remained for longer ISIs than were needed to recover from response adaptation at the best ITD. Stimuli with non-best ITDs could also induce similar adaptive effects if the neurons responded to these ITDs. NEW & NOTEWORTHY We demonstrate and characterize response adaptation in neurons of the auditory space map in the barn owl's midbrain with acoustic double-stimulation paradigms. An increase of the second level by 5 dB compensated for the observed adaptive effect. Recovery from adaptation was faster than in upstream nuclei of the auditory pathway. Our results also show that response adaptation might improve precision and selectivity in the representation of interaural time difference.


Asunto(s)
Percepción Auditiva/fisiología , Colículos Inferiores/fisiología , Neuronas/fisiología , Localización de Sonidos/fisiología , Estimulación Acústica , Potenciales de Acción , Animales , Femenino , Masculino , Estrigiformes
2.
Eur Surg Res ; 59(1-2): 48-57, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29462813

RESUMEN

BACKGROUND: Topical hemostatic agents are useful when hepatic hemorrhage is difficult to control. The aim of this study was to evaluate the hemostatic efficacy and safety of a biodegradable polyurethane-based adhesive, MAR VIVO-107 (MAR), in comparison with a clinically used fibrin glue. METHODS: Thirty female New Zealand white rabbits were randomly assigned to 3 study groups as follows: MAR (n = 10), fibrin glue (n = 10), and saline groups (n = 10). After standardized partial liver resection was performed, each agent was immediately applied to the wound area. Bleeding time until hemostasis and blood loss were recorded. After 7 days, body weight, hematology parameters, and serum levels of aspartate aminotransferase, alanine aminotransferase, and lactate dehydrogenase were measured. Simultaneously, the severity of intra-abdominal adhesion was evaluated. RESULTS: The mean bleeding time in the MAR (38 ± 10 s) and fibrin glue groups (65 ± 17 s) was significantly shorter than that in the saline group (186 ± 12 s). Similarly, the mean blood loss in the MAR (9 ± 3 g) and fibrin glue groups (9 ± 3 g) was significantly less than that in the saline group (23 ± 4 g). No significant differences in bleeding time and blood loss were found between the MAR and fibrin glue groups. The postoperative survival rate was 100% in all the groups. Body weight as well as hematological and serum biochemical values on day 7 were within the small and physiological range when compared with the preoperative baseline values, and significant differences were not detected among the MAR, fibrin glue, and saline groups. The severities of adhesion were similar between the 3 groups. CONCLUSION: Our data demonstrated that MAR was not inferior to fibrin glue in terms of hemostatic efficacy and safety.


Asunto(s)
Hemostasis Quirúrgica/métodos , Hemostáticos/farmacología , Hepatectomía/métodos , Adhesivos Tisulares/farmacología , Animales , Femenino , Adhesivo de Tejido de Fibrina/farmacología , Poliuretanos/farmacología , Cuidados Posoperatorios , Conejos
3.
Eur Surg Res ; 58(5-6): 193-203, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28433992

RESUMEN

BACKGROUND: The pig is one of the most frequently used large animal models for biomedical research, especially in the field of translational research and surgical models. While standard livestock breeds are used in short-term and acute studies, minipig breeds are the preferred breeds in long-term and chronic studies due to their limited growth and body weight. OBJECTIVE: In consideration of the 3R principle (refinement, reduction, replacement) and the increasing demand, the aim of this study was to generate a new, robust, non-specific-pathogen-free minipig breed, the Aachen minipig. METHODS: Phenotype, genotype, and hematological as well as clinical chemistry parameters were characterized, and reference values of the Aachen minipig were generated and compared to the values in the commonly used Göttingen minipig. Organ weights of the heart, kidney, liver, lung, spleen, and brain were determined using a laboratory balance. Blood samples were collected for hematology and clinical chemistry. Assessment of genetic diversity was performed by microsatellite markers. Nasal swabs were collected from 11 individual minipigs representing 6 races for DNA extraction. DNA was quantified and the identity and origin of the Aachen minipigs at the genomic level was determined by microsatellites. RESULTS: The Aachen minipig established here is based on the Mini-LEWE breed and consists of the Vietnamese potbelly pig, the Schwäbisch Hällisch Landpig, the German Landrace, and the Minnesota minipig. Relative organ weights (lung, heart, kidneys, brain), hematology (hemoglobin, hematocrit, platelet count, mean corpuscular hemoglobin concentration, segmented neutrophils, lymphocytes, eosinophils, basophils), and clinical chemistry parameters (sodium, calcium, chloride, alkaline phosphatase, aspartate aminotransferase, alanine aminotransferase, gamma-glutamyl transferase, lactate dehydrogenase, triglycerides, blood urea nitrogen, creatinine, total bilirubin, total protein, creatine kinase) of the Aachen minipigs and the Göttingen minipigs were not significantly different. Significant differences where only seen in relative organ weights (liver, spleen), hematology (red blood cell count, mean corpuscular volume, mean corpuscular hemoglobin, white blood cell count, banded neutrophils, monocytes), and clinical chemistry parameters (inorganic phosphorus, potassium, glucose, cholesterol, albumin, amylase). CONCLUSION: The Aachen minipig is a suitable model for research due to its similarity to other minipig breeds, especially the Göttingen minipig. The reference values established in this study may be used for the comparison of scientific data and encourage the use of the Aachen minipig as an animal model for biomedical research.


Asunto(s)
Modelos Animales , Porcinos Enanos/fisiología , Animales , Porcinos
4.
Surg Innov ; 24(5): 423-431, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28715950

RESUMEN

BACKGROUND: Despite modern surgical techniques, insufficient hemostasis after liver trauma is still a major cause of morbidity and mortality after injury. Therefore, efficient hemostatic agents are indicated. In this study, we evaluated the hemostatic efficacy of a novel synthetic wound adhesive (MAR-VIVO-107) based on polyurethane/polyurea, compared with a widely used fibrin adhesive (Tisseel). MATERIALS AND METHODS: Twelve German Landrace pigs were randomly assigned to 2 groups. The animals were operated under sterile conditions. A midline laparotomy was performed and the left liver lobe was isolated and resected, using a surgical scissor, in order to induce hepatic trauma. MAR-VIVO-107 or Tisseel was applied to the resected area. The animals were monitored for 60 minutes; thereafter, they were sacrificed under anesthesia. Blood and tissue samples were collected pre- and postresection for biochemical and hematological analyses. RESULTS: MAR-VIVO-107 versus Tisseel (mean ± SD, P value)-postsurgical survival rate was 100% in both groups. Bleeding time was significantly higher in Tisseel compared with MAR-VIVO-107 (10.3 ± 5.0 vs 3.7 ± 1.5 minutes, P = .0124). In trend, blood loss was less in the MAR-VIVO-107 group (54.3 ± 34.9 vs 105.5 ± 65.8 g, P = .222). Aspartate transaminase levels were significantly lower in the MAR-VIVO-107 group when compared with the Tisseel group (39.0 ± 10.0 vs 72.4 ± 23.4 U/L, P = .0459). CONCLUSION: The efficacy of MAR-VIVO-107 and comparable performance to the gold standard fibrin have been shown under pre-clinical conditions. MAR-VIVO-107 permits hemorrhage control within seconds, even in wet environment.


Asunto(s)
Hemostasis Quirúrgica/instrumentación , Hemostáticos/farmacología , Hepatectomía/métodos , Hígado/efectos de los fármacos , Hígado/cirugía , Adhesivos Tisulares/farmacología , Animales , Pérdida de Sangre Quirúrgica/prevención & control , Diseño de Equipo , Hemostasis Quirúrgica/métodos , Hemostáticos/administración & dosificación , Hemostáticos/uso terapéutico , Hígado/irrigación sanguínea , Polímeros , Poliuretanos , Porcinos , Adhesivos Tisulares/administración & dosificación , Adhesivos Tisulares/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA