Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(4): 715-726, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38348517

RESUMEN

INTRODUCTION: Heart failure (HF) and atrial fibrillation (AF) frequently co-exist. Contemporary classification of HF categorizes it into HF with reduced ejection fraction (HFrEF), HF with mildly reduced ejection fraction (HFmrEF), and HF with preserved ejection fraction (HFpEF). Aggregate data comparing the risk profile of AF between these three HF categories are lacking. METHODS: We conducted a systematic review and meta-analysis aimed at determining any significant differences in AF-associated all-cause mortality, HF hospitalizations, cardiovascular mortality (CV), and stroke between HFrEF, HFmrEF, and HFpEF. A systematic search of PubMed, EMBASE, and Cochrane Library databases until February 28, 2023. Data were combined using DerSimonian-Laird random effects model. RESULTS: A total of 22 studies comprising 248 323 patients were retained: HFrEF 123 331 (49.7%), HFmrEF 40 995 (16.5%), and HFpEF 83 997 (33.8%). Pooled baseline AF prevalence was 36% total population, 30% HFrEF, 36% HFmrEF, and 42% HFpEF. AF was associated with a higher risk of all-cause mortality in the total population with pooled hazard ratio (HR) = 1.13 (95% confidence interval [CI] = 1.07-1.21), HFmrEF (HR = 1.25, 95% CI = 1.05-1.50) and HFpEF (HR = 1.16, 95% CI = 1.09-1.24), but not HFrEF (HR = 1.03, 95% CI = 0.93-1.14). AF was associated with a higher risk of HF hospitalizations in the total population (HR = 1.29, 95% CI = 1.14-1.46), HFmrEF (HR = 1.64, 95% CI = 1.20-2.24), and HFpEF (HR = 1.46, 95% CI = 1.17-1.83), but not HFrEF (HR = 1.01, 95% CI = 0.87-1.18). AF was only associated with CV in the HFpEF subcategory but was associated with stroke in all three HF subtypes. CONCLUSIONS: AF appears to be associated with a higher risk of all-cause mortality and HF hospitalization in HFmrEF and HFpEF. With these findings, the paucity of data and treatment guidelines on AF in the HFmrEF subgroup becomes even more significant and warrant further investigations.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Hospitalización , Volumen Sistólico , Función Ventricular Izquierda , Humanos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/mortalidad , Medición de Riesgo , Factores de Riesgo , Femenino , Masculino , Anciano , Pronóstico , Persona de Mediana Edad , Prevalencia , Causas de Muerte , Accidente Cerebrovascular/mortalidad , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/fisiopatología , Anciano de 80 o más Años , Factores de Tiempo
2.
J Cardiovasc Electrophysiol ; 35(10): 1962-1971, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39113311

RESUMEN

INTRODUCTION: High-frequency low-tidal-volume (HFLTV) ventilation during radiofrequency catheter ablation (RFCA) for paroxysmal atrial fibrillation (PAF) has been shown to be superior to standard ventilation (SV) in terms of procedural efficiency, acute and long-term clinical outcomes. Our study aimed to compare ablation lesions characteristics utilizing HFLTV ventilation versus SV during RFCA of PAF. METHODS: A retrospective analysis was conducted on patients who underwent pulmonary vein isolation (PVI) for PAF between August 2022 and March 2023, using high-power short-duration ablation. Thirty-five patients underwent RFCA with HFLTV ventilation and were matched with another cohort of 35 patients who underwent RFCA with SV. Parameters including ablation duration, contact force (CF), impedance drop, and ablation index were extracted from the CARTONET database for each ablation lesion. RESULTS: A total of 70 patients were included (HFLTV = 35/2484 lesions, SV = 35/2830 lesions) in the analysis. There were no differences in baseline characteristics between the groups. While targeting the same ablation index, the HFLTV ventilation group demonstrated shorter average ablation duration per lesion (12.3 ± 5.0 vs. 15.4 ± 8.4 s, p < .001), higher average CF (17.0 ± 8.5 vs. 10.5 ± 4.6 g, p < .001), and greater impedance reduction (9.5 ± 4.6 vs. 7.7 ± 4.1 ohms, p < .001). HFLTV ventilation group also demonstrated shorter total procedural time (61.3 ± 25.5 vs. 90.8 ± 22.8 min, p < .001), ablation time (40.5 ± 18.6 vs. 65.8 ± 22.5 min, p < .001), and RF time (15.3 ± 4.8 vs. 22.9 ± 9.7 min, p < .001). CONCLUSION: HFLTV ventilation during PVI for PAF was associated with improved ablation lesion parameters and procedural efficiency compared to SV.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Frecuencia Cardíaca , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Femenino , Masculino , Ablación por Catéter/efectos adversos , Estudios Retrospectivos , Persona de Mediana Edad , Resultado del Tratamiento , Anciano , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Factores de Tiempo , Potenciales de Acción , Bases de Datos Factuales
3.
Heart Fail Rev ; 29(1): 165-178, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37855988

RESUMEN

Cardiac resynchronization therapy (CRT) significantly reduces secondary mitral regurgitation (MR) in patients with severe left ventricular systolic dysfunction. However, uncertainty remains as to whether improvement in secondary MR correlates with improvement with mortality seen in CRT. We conducted a meta-analysis to determine the association of persistent unimproved significant secondary MR (defined as moderate or moderate-to-severe or severe MR) compared to improved MR (no MR or mild MR) post-CRT with all-cause mortality, cardiovascular mortality, and heart failure hospitalization. A systematic search of PubMed, EMBASE, and Cochrane Library databases till July 31, 2022 identified studies reporting clinical outcomes by post-CRT secondary MR status. In 12 prospective studies of 4954 patients (weighted mean age 66.8 years, men 77.8%), the median duration of follow-up post-CRT at which patients were re-evaluated for significant secondary MR was 6 months and showed significant relative risk reduction of 30% compared to pre-CRT. The median duration of follow-up post-CRT for ascertainment of main clinical outcomes was 38 months. The random effects pooled hazard ratio (95% confidence interval) of all-cause mortality in patients with unimproved secondary MR compared to improved secondary MR was 2.00 (1.57-2.55); p < 0.001). There was insufficient data to evaluate secondary outcomes in a meta-analysis, but limited data that examined the relationship showed significant association of unimproved secondary MR with increased cardiovascular mortality and heart failure hospitalization. The findings of this meta-analysis suggest that lack of improvement in secondary MR post-CRT is associated with significantly elevated risk of all-cause mortality and possibly cardiovascular mortality and heart failure hospitalization. Future studies may investigate approaches to address persistent secondary MR post-CRT to help improved outcome in this population.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Masculino , Humanos , Anciano , Insuficiencia de la Válvula Mitral/complicaciones , Terapia de Resincronización Cardíaca/efectos adversos , Resultado del Tratamiento , Estudios Prospectivos
4.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38812433

RESUMEN

AIMS: Significant changes in tricuspid regurgitation (TR) and mitral regurgitation (MR) post-cardiac implantable electronic devices (CIEDs) are increasingly recognized. However, uncertainty remains as to whether the risk of CIED-associated TR and MR differs with right ventricular pacing (RVP) via CIED with trans-tricuspid RV leads, compared with cardiac resynchronization therapy (CRT), conduction system pacing (CSP), and leadless pacing (LP). The study aims to synthesize extant data on risk and prognosis of significant post-CIED TR and MR across pacing strategies. METHODS AND RESULTS: We searched PubMed, EMBASE, and Cochrane Library databases published until 31 October 2023. Significant post-CIED TR and MR were defined as ≥ moderate. Fifty-seven TR studies (n = 13 723 patients) and 90 MR studies (n = 14 387 patients) were included. For all CIED, the risk of post-CIED TR increased [pooled odds ratio (OR) = 2.46 and 95% CI = 1.88-3.22], while the risk of post-CIED MR reduced (OR = 0.74, 95% CI = 0.58-0.94) after 12 and 6 months of median follow-up, respectively. Right ventricular pacing via CIED with trans-tricuspid RV leads was associated with increased risk of post-CIED TR (OR = 4.54, 95% CI = 3.14-6.57) and post-CIED MR (OR = 2.24, 95% CI = 1.18-4.26). Binarily, CSP did not alter TR risk (OR = 0.37, 95% CI = 0.13-1.02), but significantly reduced MR (OR = 0.15, 95% CI = 0.03-0.62). Cardiac resynchronization therapy did not significantly change TR risk (OR = 1.09, 95% CI = 0.55-2.17), but significantly reduced MR with prevalence pre-CRT of 43%, decreasing post-CRT to 22% (OR = 0.49, 95% CI = 0.40-0.61). There was no significant association of LP with post-CIED TR (OR = 1.15, 95% CI = 0.83-1.59) or MR (OR = 1.31, 95% CI = 0.72-2.39). Cardiac implantable electronic device-associated TR was independently predictive of all-cause mortality [pooled hazard ratio (HR) = 1.64, 95% CI = 1.40-1.90] after median of 53 months. Mitral regurgitation persisting post-CRT independently predicted all-cause mortality (HR = 2.00, 95% CI = 1.57-2.55) after 38 months. CONCLUSION: Our findings suggest that, when possible, adoption of pacing strategies that avoid isolated trans-tricuspid RV leads may be beneficial in preventing incident or deteriorating atrioventricular valvular regurgitation and might reduce mortality.


Asunto(s)
Desfibriladores Implantables , Insuficiencia de la Válvula Mitral , Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Humanos , Estimulación Cardíaca Artificial/efectos adversos , Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Marcapaso Artificial/efectos adversos , Pronóstico , Factores de Riesgo , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/fisiopatología
5.
Pacing Clin Electrophysiol ; 47(5): 697-701, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38597183

RESUMEN

BACKGROUND: Patients ≥80 with implantable cardioverter-defibrillators (ICDs) have high rates of hospitalization and mortality, yet few have documented advance directives. We sought to determine the prevalence of advance directives in adults ≥80 years with ICDs, focusing on those with frailty and cognitive impairment. METHODS: Prospective cohort study (July 2016-May 2019) in an electrophysiology clinic. Presence of advance directives (health care proxies [HCP] and living wills [LW], or medical orders for life-sustaining treatment [MOLST]) was determined by medical record review. Frailty and cognitive impairment were screened using 4-m gait speed and Mini-Cog. RESULTS: 77 Veterans were evaluated. Mean age 84 years, 100% male, 70% frail. Overall, 52 (68%) had an HCP and 37 (48%) had a LW/MOLST. Of 67 with cognitive testing, 36% were impaired. HCP documentation was similar among frail and non-frail (69% vs. 65%). LW/MOLST was more prevalent among frail versus non-frail (52% vs. 39%). There was no difference in HCP documentation by cognitive status (67%). A LW/MOLST was more frequent for cognitively impaired versus non-impaired (50% vs. 42%). Among 19 Veterans who were frail and cognitively impaired, 14 (74%) had an HCP and 11 (58%) had a LW/MOLST. CONCLUSIONS: Most Veterans had a documented advance directive, but a significant minority did not. Simple frailty and cognitive screening tools can rapidly identify patients for whom discussion of advance directives is especially important.


Asunto(s)
Directivas Anticipadas , Desfibriladores Implantables , Humanos , Masculino , Femenino , Anciano de 80 o más Años , Estudios Prospectivos , Disfunción Cognitiva , Fragilidad
6.
J Cardiovasc Electrophysiol ; 34(3): 497-501, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36640437

RESUMEN

BACKGROUND: Patients with cardiac implantable electronic devices (CIEDs) living in rural areas have difficulty obtaining follow-up visits for device interrogation and programming in specialized healthcare facilities. OBJECTIVE: To describe the use of an assisted reality device designed to provide front-line workers with real-time online support from a remotely located specialist (Realwear HTM-1; Realwear) during CIED assistance in distant rural areas. METHODS: This is a prospective study of patients requiring CIED interrogation using the Realwear HMT-1 in a remote rural population in Colombia between April 2021 and June 2022. CIED interrogation and device programming were performed by a general practitioner and guided by a cardiac electrophysiologist. Non-CIED-related medical interventions were allowed and analyzed. The primary objective was to determine the incidence of clinically significant CIED alerts. Secondary objectives were the changes medical interventions used to treat the events found in the device interrogations regarding non-CIED related conditions. RESULTS: A total of 205 CIED interrogations were performed on 139 patients (age 69 ± 14 years; 54% female). Clinically significant CIED alerts were reported in 42% of CIED interrogations, consisting of the detection of significant arrhythmias (35%), lead malfunction (3%), and device in elective replacement interval (3.9%). Oral anticoagulation was initiated in 8% of patients and general medical/cardiac interventions unrelated to the CIED were performed in 52% of CIED encounters. CONCLUSION: Remote assistance using a commercially available assisted reality device has the potential to provide specialized healthcare to patients in difficult-to-reach areas, overcoming current difficulties associated with RM, including the inability to change device programming. Additionally, these interactions provided care beyond CIED-related interventions, thus delivering significant social and clinical impact to remote rural populations.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Estudios Prospectivos , Arritmias Cardíacas/terapia
7.
Europace ; 25(1): 175-184, 2023 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-36196043

RESUMEN

AIMS: The aim of this study is to provide guidance for the clinical interpretation of electrocardiograms (ECGs) in prone position and to establish the electroanatomic explanations for the possible differences to supine position ECGs that may be observed. Additionally, to determine if prone back ECG can be used as an alternative to standard ECG in patients who may benefit from prone position. METHODS AND RESULTS: The ECG in supine (standard ECG), prone back (precordial leads placed on the patient's back), and prone anterior position (precordial leads placed in the standard position with the subjects in prone position) were prospectively examined on 85 subjects. Comparisons of ECG parameters between these positions were performed. Computed tomography (CT) scans were performed in both positions to determine possible electroanatomic aetiologies for prone-associated ECG changes. There were significant differences in QRS amplitude in Leads V1-V5 between supine and prone positions. Q waves were more frequently observed in prone back position vs. supine position (V1: 74.1 vs. 10.6%, P < 0.0001; V2: 23.5 vs. 0%, P < 0.0001, respectively). Flat and inverted T waves were more common in prone back leads (V1: 98 vs. 66%, P < 0.0001; V2: 96 vs. 8%, P < 0.0001; V3: 45 vs. 7%, P < 0.0001). The 3D-CT reconstructions measurements corroborated the significant inverse correlation between QRS amplitude and the distance from the centre of the heart to the estimated lead positions. CONCLUSION: In prone back position ECG, low QRS amplitude should not be misinterpreted as low voltage conditions, neither should Q waves and abnormal T waves are considered anteroseptal myocardial infarction. These changes can be explained by an increased impedance (due to interposing lung tissue) and by the increased distance between the electrodes to the centre of the heart.


Asunto(s)
Electrocardiografía , Posicionamiento del Paciente , Humanos , Posición Prona , Estudios Prospectivos , Electrocardiografía/métodos , Corazón
8.
Europace ; 23(8): 1262-1274, 2021 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-33496319

RESUMEN

AIMS: Response to cardiac resynchronization therapy (CRT) is associated with improved survival, and reduction in heart failure hospitalization, and ventricular arrhythmia (VA) risk. However, the impact of CRT super-response [CRT-SR, increase in left ventricular ejection fraction (LVEF) to ≥ 50%] on VA remains unclear. METHODS AND RESULTS: We undertook a meta-analysis aimed at determining the impact of CRT response and CRT-SR on risk of VA and all-cause mortality. Systematic search of PubMed, EMBASE, and Cochrane databases, identifying all relevant English articles published until 31 December 2019. A total of 34 studies (7605 patients for VA and 5874 patients for all-cause mortality) were retained for the meta-analysis. The pooled cumulative incidence of appropriate implantable cardioverter-defibrillator therapy for VA was significantly lower at 13.0% (4.5% per annum) in CRT-responders, vs. 29.0% (annualized rate of 10.0%) in CRT non-responders, relative risk (RR) 0.47 [95% confidence interval (CI) 0.39-0.56, P < 0.0001]; all-cause mortality 3.5% vs. 9.1% per annum, RR of 0.38 (95% CI 0.30-0.49, P < 0.0001). The pooled incidence of VA was significantly lower in CRT-SR compared with CRT non-super-responders (non-responders + responders) at 0.9% vs. 3.8% per annum, respectively, RR 0.22 (95% CI 0.12-0.40, P < 0.0001); as well as all-cause mortality at 2.0% vs. 4.3%, respectively, RR 0.47 (95% CI 0.33-0.66, P < 0.0001). CONCLUSIONS: Cardiac resynchronization therapy super-responders have low absolute risk of VA and all-cause mortality. However, there remains a non-trivial residual absolute risk of these adverse outcomes in CRT responders. These findings suggest that among CRT responders, there may be a continued clinical benefit of defibrillators.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Arritmias Cardíacas/terapia , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
9.
Heart Rhythm ; 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39094723

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is commonly associated with cardiac structural abnormalities including mitral regurgitation (MR). Contemporary guidelines recommend consideration of early rhythm control strategies including catheter ablation (CA) for AF. However, the long-term efficacy of CA is highly variable across studies and patient populations, and the effect of coexisting MR on AF recurrence remains unclear. OBJECTIVE: A systematic review and meta-analysis was performed to determine the impact of significant MR (defined as ≥moderate) on AF recurrence rate after CA and whether CA for AF is associated with significant changes in the severity of MR. METHODS: A systematic search of PubMed, Embase, Web of Science, and Cochrane databases for all English-language studies published to December 31, 2023, was performed. RESULTS: A total of 17 studies (N = 2624 patients) were retained for meta-analysis. The pooled recurrence proportion of AF after CA in patients with baseline significant MR was 36% (95% CI, 27%-46%) compared with 27% (14%-41%) in patients without. The pooled hazard ratio (95% CI) for AF recurrence after CA in the presence of significant MR was 2.47 (1.52-4.01; P < .001; Egger test P value, .0583). The pooled proportion of patients who witnessed MR improvement to nonsignificant (ie,

10.
Pacing Clin Electrophysiol ; 36(3): e74-6, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22469186

RESUMEN

Ultrasound imaging has been used in a range of cardiac interventions. We describe the use of intravascular ultrasound to assist in coronary sinus lead implantation in a patient where contrast venography was contraindicated.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Seno Coronario/diagnóstico por imagen , Ultrasonografía Intervencional , Anafilaxia/inducido químicamente , Medios de Contraste/efectos adversos , Humanos , Masculino , Implantación de Prótesis/métodos
11.
Pacing Clin Electrophysiol ; 36(1): 109-12, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23121111

RESUMEN

BACKGROUND: Few studies have examined the prevalence of permanent pacemaker (PPM) malfunction among patients with a previously implanted pacemaker admitted to the hospital with syncope. OBJECTIVE: This study sought to examine causes of syncope in patients with a previously implanted pacemaker admitted to our hospital with syncope. METHODS: We retrospectively reviewed our hospital admission database for patients who had both keywords "syncope" and "pacemaker" as their diagnoses from January 1, 1995 until June 1, 2012. One hundred and sixty-two patients who were admitted to the hospital because of syncope and had a PPM implanted prior to the index syncopal episode were included. All patients had pacemakers interrogated during the admission. Two independent physicians examined the discharge summary of each patient and determined the cause of syncope in each case. RESULTS: Of the 162 patients studied, eight (4.9%) were found to have pacemaker system malfunction as a cause of syncope. In 96 patients (59.2%), the cause of syncope could not be determined prior to hospital discharge. Among the identifiable causes of syncope, orthostatic hypotension was most prevalent (16%) followed by vasovagal (6%), severe aortic stenosis (4.3%), atrial arrhythmia (3.1%), acute and subacute infection (3.1%), and other less prevalent causes (3.1%). CONCLUSION: In this study, PPM system malfunction was rarely a cause of syncope in patients admitted to the hospital with a previously implanted device.


Asunto(s)
Causalidad , Falla de Equipo/estadística & datos numéricos , Marcapaso Artificial/estadística & datos numéricos , Admisión del Paciente/estadística & datos numéricos , Síncope/epidemiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Insuficiencia Cardíaca , Humanos , Israel/epidemiología , Masculino , Persona de Mediana Edad , Prevalencia , Factores de Riesgo
12.
J Electrocardiol ; 45(6): 764-9, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22819483

RESUMEN

OBJECTIVES: The aim of this study was to investigate if T-wave inversion (TWI) in the settings of electrocardiogram (ECG)-left ventricular hypertrophy (LVH) is associated with advanced diastolic dysfunction (DD) in subjects with preserved ejection fraction (EF). BACKGROUND: Animal studies suggested that an abnormal transmural repolarization sequence from endocardium to epicardium may contribute to DD. However, little is known about abnormal repolarization sequence and DD in humans. METHODS: We studied 231 patients with ECG-diagnosed LVH and with an EF of 50% or greater (measured within 6 months of the index ECG). T-wave inversion was assessed on leads I, aVL, V(4), V(5), or V(6). Diastolic dysfunction was defined based on echocardiographic estimation of the left atrial pressure. We used multiple logistic regression to estimate the odds ratio of DD comparing patients with TWI with those without TWI. RESULTS: The average age was 65.0 ± 14.2 years, and 61% were women. The mean EF was 61.8% ± 6.6%. Patients with TWIs were more likely to have coronary artery disease (P = .013) and diabetes (P = .007). There was a 5.6-fold increased odds of DD in patients with TWI compared with those without TWI in a model adjusting for sex, age, relative wall thickness, body mass index, hypertension, coronary artery disease, diabetes, hyperlipidemia, and smoking. When comparing different echocardiographic estimates of the left atrial pressure, patients with TWI displayed higher values for septal and lateral E/e', left atrial volume index, and right ventricular/right atrial peak systolic gradient (P < .01 for each parameter). CONCLUSIONS: T-wave inversion is associated with increased odds of DD in patients with ECG-LVH with preserved systolic function. The reversal of the normal sequence of repolarization manifested on the 12-lead ECG as TWI may be a factor to DD.


Asunto(s)
Electrocardiografía/métodos , Frecuencia Cardíaca , Hipertrofia Ventricular Izquierda/diagnóstico , Hipertrofia Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/fisiopatología , Anciano , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
Clin Cardiol ; 41(5): 652-659, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29532498

RESUMEN

BACKGROUND: The association between posttraumatic stress disorder (PTSD) and mortality in patients undergoing implantable cardioverter-defibrillator (ICD) placement has not been evaluated in US veterans. HYPOTHESIS: PTSD in veterans with ICD is associated with increased mortality. METHODS: We studied a retrospective cohort of 25 678 veterans who underwent ICD implantation between September 30, 2002, and December 31, 2011. Of these subjects, 3280 carried the diagnosis of PTSD prior to ICD implantation. Primary outcome was all-cause mortality between date of ICD implantation and end of follow-up (September 30, 2013). We used Cox proportional hazard models to compute multivariable adjusted hazard ratios with corresponding 95% confidence intervals for the relation between PTSD diagnosis and death following ICD placement. RESULTS: During a mean follow-up of 4.21 ± 2.62 years, 11 015 deaths were reported. The crude incidence rate of death was 87.8 and 103.9/1000 person-years for people with and without PTSD, respectively. We did not find an association between presence of PTSD before or after ICD implantation and incident death when adjusted for multiple risk factors (hazard ratio: 1.003, 95% confidence interval: 0.948-1.061). In secondary analysis, no statistically significant association was found. CONCLUSIONS: In this retrospective cohort study among more than 25 000 veterans undergoing ICD implantation, almost 13% had a diagnosis of PTSD. Subjects with PTSD were significantly younger, yet they had a higher incidence of coronary heart disease, major cardiac comorbidities, cancer, and mental health conditions. We found no association between presence of PTSD before or after ICD implantation and incident death when adjusting for all covariates.


Asunto(s)
Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/mortalidad , Trastornos por Estrés Postraumático/mortalidad , United States Department of Veterans Affairs , Anciano , Arritmias Cardíacas/diagnóstico , Causas de Muerte , Comorbilidad , Bases de Datos Factuales , Cardioversión Eléctrica/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Factores de Riesgo , Trastornos por Estrés Postraumático/diagnóstico , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología , Salud de los Veteranos
16.
J Am Heart Assoc ; 3(4)2014 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-24980132

RESUMEN

BACKGROUND: Inflammatory processes have been associated with an increased risk of atrial fibrillation (AF), potentially allowing for preventive therapy by anti-inflammatory agents such as aspirin. However, the effect of chronic aspirin on the incidence of AF has not been evaluated in a prospective cohort followed for an extended period. METHODS AND RESULTS: This study was comprised of a prospective cohort of 23 480 male participants of the Physicians' Health Study. Aspirin intake and covariates were estimated using self-reported questionnaires. Incident AF was ascertained through yearly follow-up questionnaires. Cox's regression, with adjustment for multiple covariates, was used to estimate relative risk of AF. Average age at baseline was 65.1±8.9 years. During a mean follow-up of 10.0 years, 2820 cases of AF were reported. Age-standardized incidence rates were 12.6, 11.1, 12.7, 11.3, 15.8, and 13.8/1000 person-years for people reporting baseline aspirin intake of 0, <14 days per year, 14 to 30 days per year, 30 to 120 days per year, 121 to 180 days per year, and >180 days per year, respectively. Multivariable adjusted hazard ratios (95% confidence interval) for incident AF were 1.00 (reference), 0.88 (0.76 to 1.02), 0.93 (0.76 to 1.14), 0.96 (0.80 to 1.14), 1.07 (0.80 to 1.14), and 1.04 (0.94 to 1.15) across consecutive categories of aspirin intake. Analysis of the data using time-varying Cox's regression model to update aspirin intake over time showed similar results. CONCLUSIONS: In a large cohort of males followed for a long period, we did not find any association between aspirin use and incident AF.


Asunto(s)
Antiinflamatorios no Esteroideos/uso terapéutico , Aspirina/uso terapéutico , Fibrilación Atrial/epidemiología , Anciano , Estudios de Cohortes , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Factores Protectores , Factores de Riesgo
17.
J Atr Fibrillation ; 6(1): 836, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-28496856

RESUMEN

Although atrial fibrillation is a very common medical problem in general population and has a high incidence in the setting of open heart surgery, there are very few therapies to prevent occurrence or recurrence of atrial fibrillation. N-3 polyunsaturated fatty acids have been shown to change basic physiologic properties of the atrial tissue to make it less susceptible to atrial fibrillation. In this review, we first describe basic physiological mechanisms thought to be responsible for these changes and then discuss observational and interventional studies evaluating the use n-3 polyunsaturated fatty acids for primary and secondary prevention of atrial fibrillation in the general population, in subjects undergoing open heart surgery, and in special subgroups of patients.

18.
Circ Arrhythm Electrophysiol ; 6(2): 252-6, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23515264

RESUMEN

BACKGROUND: Although previous studies have suggested that competitive athletes have a higher risk of atrial fibrillation than the general population, limited and inconsistent data are available on the association between regular physical activity and the risk of atrial fibrillation. METHODS AND RESULTS: A systematic, comprehensive literature search was performed using MEDLINE, EMBASE, and COCHRANE until 2011. Extracted data from the eligible studies were meta-analyzed using fixed effects model. Four studies, which included 95 526 subjects, were eligible for meta-analysis. For all of the studies included, the extreme groups (ie, maximum versus minimal amount of physical activity) were used for the current analyses. The total number of participants belonging to the extreme groups was 43 672. The pooled odds ratio (95% confidence interval) for atrial fibrillation among regular exercisers was 1.08 (0.97-1.21). CONCLUSIONS: Our data do not support a statistically significant association between regular physical activity and increased incidence of atrial fibrillation.


Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/fisiopatología , Actividad Motora , Medición de Riesgo/métodos , Salud Global , Humanos , Incidencia , Oportunidad Relativa , Factores de Riesgo
19.
Pacing Clin Electrophysiol ; 28(8): 851-4, 2005 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16105014

RESUMEN

We present the interesting case of a young man with borderline wide QRS complexes noted on electrocardiogram (ECG). The diagnosis of an unusual form of preexcitation was reached using observations from intracardiac tracings at electrophysiology study. Atrial pacing consistently resulted in further widening of the first conducted QRS complex, and the physiology underlying this unusual finding is explored.


Asunto(s)
Síndromes de Preexcitación/diagnóstico , Adulto , Estimulación Cardíaca Artificial/métodos , Diagnóstico Diferencial , Electrocardiografía , Humanos , Masculino , Síndromes de Preexcitación/fisiopatología , Síndromes de Preexcitación/terapia
20.
J Card Fail ; 9(2): 141-6, 2003 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-12751135

RESUMEN

BACKGROUND: Paired electrical stimulation and postextrasystolic potentiation (PESP) of contractility has been extensively studied in ventricular myocardium, but less is known about PESP of atrial contractility. Our aim was to determine whether PESP of atrial contractility could augment left ventricular (LV) preload and improve LV systolic performance. METHODS AND RESULTS: A paired electrical stimulus closely following the pacing stimulus was applied to isolated atrial and ventricular myocardium from 4 dog hearts, and the interval dependent force potentiation was examined. In isolated atrial myocardium, paired pacing increased the active tension from a baseline of 1.36 +/- 0.23 to 2.60 +/- 0.57 g/mm(2); in ventricular myocardium active tension increased from 2.58 +/- 0.42 to 3.81 +/- 0.27 g/mm(2) (both P <.01). Then, LV pressure (micromanometer) and segment length (ultrasonic crystals) were measured in the intact hearts of 7 anesthetized dogs in which premature stimuli were applied to the atrium. In intact hearts, paired pacing of the atrium (coupling interval 200 ms) increased LV end-diastolic pressure from 3.8 +/- 1.0 to 6.4 +/- 1.0 mm Hg; systolic pressure increased from 105 +/- 6 to 112 +/- 7 mm Hg (both P <.05). LV pressure-length loop area (regional stroke work) increased 10.5 +/- 0.2%. CONCLUSIONS: Isolated atrial myocardium exhibits substantial PESP of contractility, which is similar to ventricular myocardium. In the intact heart, atrial PESP augments LV systolic performance by effecting an increase in LV preload. This technique may provide a means of improving cardiac performance in patients with heart failure.


Asunto(s)
Función Atrial/fisiología , Estimulación Cardíaca Artificial , Contracción Miocárdica/fisiología , Función Ventricular Izquierda/fisiología , Animales , Estimulación Cardíaca Artificial/métodos , Perros
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA