Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38831052

RESUMEN

Displaced intra-articular calcaneus fractures (DIACFs) are difficult injuries to treat and are often encountered by orthopedic surgeons. For DIACFs treated nonoperatively or with open reduction internal fixation (ORIF), a common complication is painful subtalar arthritis and the need for a secondary subtalar fusion, which prolongs the overall recovery time. One treatment option to address this sequela involves ORIF with subtalar fusion as the primary treatment. We describe a reproducible, minimally invasive surgical technique for primary ORIF with subtalar fusion when the calcaneal tuberosity is amendable to cannulated screw fixation to treat these complex calcaneal fractures. Our technique offers advantages compared to other techniques in that it avoids screw traffic, allows easy bony compression of the subtalar joint, and minimizes soft tissue damage via percutaneous screw fixation. Fourteen fractured calcanei in 12 patients underwent our technique and all achieved bony union with a median time to fusion of 107.5 days (range, 54-530 days). Eight patients returned to work with the remaining 4 patients having an unknown work status at last follow-up, although 2 of these 4 patients resumed normal activities. Only 1 patient experienced a complication, which was an infection after achieving bony union, and was treated with successful hardware removal and our infection protocol. Overall, we conclude our surgical technique offers a successful option in the treatment of DIACFs when the calcaneal tuberosity is amendable to cannulated screw fixation.

2.
Eur J Orthop Surg Traumatol ; 33(6): 2555-2563, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36645494

RESUMEN

INTRODUCTION: Hip fractures are common injuries in the elderly, with an incidence that continues to rise. The femoral neck system (FNS) recently emerged as a novel treatment option for femoral neck fractures, but long-term survivability of the implant remains uncertain. The purpose of this study is to evaluate survivability of the FNS and assess risk factors for implant failure. METHODS: One hundred five adult patients who received the FNS (DePuy Synthes, Raynham, MA) for femoral neck fractures (AO/OTA 31B) were included. Surgeries were performed within a regional hospital system comprising 18 facilities. All patients had a minimum follow-up of 1 year. The primary outcome measures were cumulative incidence of implant failure and 1-year mortality, including risk factor analysis. RESULTS: Twelve implants failed at a follow-up ranging from 17 days to 8 months, and 7 failed within 90 days. Cumulative incidence of implant failure was 2% at 30 days, 7% at 90 days, 12% at 6 months, and 13% at 1 year. Causes of implant failure included cut-out (n = 5), non-union (n = 4), peri-implant fracture (n = 2), and avascular necrosis (n = 1). Univariate Cox regression identified Pauwels type III fractures and an increasing AP Parker ratio as significant risk factors for failure. Pauwels type III fractures showed a 5.48 times higher risk compared to Pauwels types I & II. Every 10% increase in AP Parker ratio increased risk of failure by 2.39 times. The 1-year mortality rate was 21%, and univariate logistic regression identified age as the only risk factor (odds ratio = 3.71). CONCLUSIONS: The incidence of implant failure and 1-year mortality rate in this study suggests that the FNS can provide reliable fixation compared to rates in the literature, but complications are not uncommon. Avoiding Pauwels type III fractures and optimizing implant placement appear crucial to preventing implant failure. LEVEL OF EVIDENCE: Therapeutic Level IV.


Asunto(s)
Fracturas del Cuello Femoral , Osteonecrosis , Humanos , Adulto , Anciano , Cuello Femoral , Fijación Interna de Fracturas/efectos adversos , Fracturas del Cuello Femoral/cirugía , Factores de Riesgo , Resultado del Tratamiento , Estudios Retrospectivos
4.
JBJS Case Connect ; 13(2)2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-37235705

RESUMEN

CASE: A 60-year-old woman sustained a type IV capitellum fracture from falling on an outstretched arm. Open reduction internal fixation (ORIF) was performed using an anconeus approach, and a transolecranon tunnel was created to place a trochlear screw. The patient showed good clinical outcomes with almost full range of motion at 6 months. CONCLUSION: With type IV capitellum fractures, the olecranon often obstructs the screw trajectory necessary for anterior-to-posterior fixation of trochlear fragments. Drilling a transolecranon tunnel through the proximal olecranon with the elbow flexed creates a viable pathway for screw placement from a more medial starting point than what is possible with traditional techniques.


Asunto(s)
Articulación del Codo , Fracturas del Húmero , Femenino , Humanos , Persona de Mediana Edad , Fracturas del Húmero/diagnóstico por imagen , Fracturas del Húmero/cirugía , Fijación Interna de Fracturas/métodos , Reducción Abierta , Articulación del Codo/diagnóstico por imagen , Articulación del Codo/cirugía , Tornillos Óseos
5.
J Orthop Case Rep ; 13(12): 159-164, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38162348

RESUMEN

Introduction: Ipsilateral fracture of the femur and tibia, known by the moniker "floating knee," is a serious injury that primarily results from high-energy trauma. Up to 53% of patients with floating knee injuries have concurrent ligamentous injuries, with the anterior cruciate ligament (ACL) as the most commonly affected ligament. Approximately 10% of multi-ligament knee injuries consist of injuries to both the ACL and posterolateral corner (PLC); however, the literature reporting the management of this patient population is sparse, particularly, with a lack of consensus on the timing and protocol of surgical treatment. Well-characterized treatment guidelines are needed for patients with concomitant floating knee and multi-ligament knee injuries. Case Report: A 26-year-old, previously healthy male involved in a high-speed motor vehicle collision presented with upper and lower extremity, skull, and facial fractures, sacropelvic dissociation, and epidural hematoma. Here we describe a rare instance of a floating knee with a multi-ligament knee injury treated through early reconstruction of the ACL, PLC, and anterolateral ligament following stabilization of long bone fractures. Post-injury day 18, the patient underwent single-stage reconstruction of his multi-ligament knee injury. The timing of this was chosen to allow for capsular scar formation to aid in arthroscopy. Conclusion: Our surgical algorithm consists of allograft reconstruction using an all-inside ACL technique and a modified anatomical PLC technique. We recommend early (1-3 weeks) surgical treatment of multi-ligament knee injuries for patients without a closed head injury; however, an individualized treatment approach should be sought, considering the severity of ligamentous injuries, pre-injury activity level, extent of soft-tissue damage, and the activity goals of the patient post-injury. In patients with floating knee injuries, the proposed surgical algorithm here may be utilized for successful multi-ligament knee injury reconstruction.

6.
J Orthop ; 45: 37-42, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37841905

RESUMEN

Introduction: Following closed reduction of hip dislocations, computed tomography (CT) is considered standard of care to identify occult fractures or intra-articular loose bodies that may be missed on X-ray. The purpose of this study was to evaluate the sensitivity of post-reduction X-rays and the usefulness of subsequent post-reduction CT imaging. Methods: All patients presenting to our hospital system for traumatic hip dislocations from 2013 to 2022 were retrospectively reviewed. Participants were included if they had a simple dislocation of a native hip, underwent closed reduction, and received post-reduction X-ray and CT imaging. A sensitivity analysis was performed for the detection of associated fractures and intraarticular loose bodies by post-reduction X-ray, using CT as a reference standard. Results: Thirty-five subjects with a mean age of 26 years were included. Post-reduction CT revealed 6 fractures and 3 loose bodies, whereas post-reduction X-ray identified 3/6 (50%) fractures and 3/3 (100%) loose bodies. Four cases received operative management, all of which were identified by X-ray. Post-reduction X-ray had a sensitivity of 67% for identifying pathology that was subsequently found on CT, and a sensitivity of 100% for identifying pathology requiring surgery. Of the 13 cases with pre-reduction CT scans, none had new findings identified on post-reduction CT. Conclusions: Post-reduction X-rays are effective in the evaluation of acute pathology associated with closed reduction of traumatic hip dislocations, especially for cases requiring operative management. Our findings suggest that if a fracture or loose body was not identified on post-reduction X-ray, a post-reduction CT added no value in surgical decision-making and was not necessary.

7.
Cureus ; 14(8): e28474, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36176851

RESUMEN

While amputation techniques have improved over time, questions remain around how to best treat neuromas and severed nerves in the amputee population, specifically for trauma-related amputees. This systematic review investigates and summarizes outcomes following targeted muscle reinnervation (TMR) for the trauma-related amputee population. Studies were classified based on primary or secondary TMR and relevant outcomes, including the ability to use a prosthesis, post-TMR opioid use, Patient-Reported Outcomes Measurement Information System (PROMIS) scores for phantom limb pain and residual limb pain, and overall pain resolution/reduction. Following TMR for trauma-related amputation, most patients experienced neuroma pain resolution (86.2%, 95% confidence interval [CI]: 67.2-95.0%) and overall pain reduction/resolution (90.7%, 95% CI: 82.2-95.4%). No differences were seen between primary and secondary TMR. Preliminary evidence indicates that TMR is effective for preventing or treating pain in patients with trauma-related amputation, whether used in the acute or delayed setting.

8.
Cureus ; 14(1): e20954, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35154934

RESUMEN

Background and objective There is a paucity of medical literature describing the preparedness of hospital institutions to withstand the population effects of a pandemic. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the virus that causes coronavirus disease 2019 (COVID-19), has had a global impact on all facets of medicine, which has ultimately affected the medical community in a significant manner. Furthermore, there is a scarcity of research regarding the effects of COVID-19 on trauma and acute care surgery injury and admission rates. We conducted this study to examine the effects of the COVID-19 pandemic on both pediatric and adult trauma admissions, injury types, and mechanisms of injury. Materials and methods Data from the Trauma Registry was extracted for all adult (>15 years) and pediatric (<15 years) patients who consulted trauma surgery, acute care surgery, or orthopedic surgery at our center in the year immediately prior to the pandemic (March 1, 2019-February 29, 2020) and during the COVID-19 pandemic (March 1, 2020-February 28, 2021). Patient demographics, cause of injury, injury type and mechanism, and procedures performed were recorded. Results We documented a 4.2% increase in adult encounters compared to the preceding year. There was a significant difference in the distribution of mechanism of injury of adult patients between the two time periods, with the most changes seen in motor-vehicle auto, gunshot, and other vehicle injuries. However, no significant difference was seen in trauma type or intent (assault, self-inflicted, unintentional). Pediatric encounters increased by 6.4% during the COVID-19 pandemic compared to the pre-COVID-19 period. Overall, there was no detectable association between the distribution of encounters by the mechanism of injury and the time period for pediatric encounters. Conclusion This retrospective review of trauma encounters through both pre-COVID-19 and COVID-19 periods outlines the differences in factors such as demographics, injury mechanisms, and injury types between the two time periods. Overall, we expected a decrease in orthopedic-related trauma admissions during the COVID-19 pandemic; however, there was actually an increase of 4.1% in adult encounters and that of 6.4% in pediatric encounters. Our study lays out possible trends in injury patterns that can be correlated with the COVID-19 pandemic and the lockdown period. This information is useful for the healthcare system in that it demonstrates that resources should not be cut down or removed from surgical specialties. At level I facilities, resources need to be allocated for and continued to be provided to emergency rooms and operative services, including supplies and staffing. These departments need to be well-equipped to handle an increased number of trauma patients.

9.
J Orthop Surg Res ; 17(1): 210, 2022 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-35392956

RESUMEN

INTRODUCTION: Schatzker type III fractures of the tibial plateau require elevation of the depressed portions to regain articular congruity. Balloon tibioplasty has been used as an alternative to conventional metal instruments for elevation of the lateral tibial plateau. This study compared functional outcomes following balloon tibioplasty or conventional osteosynthesis techniques in patients with type III fractures of the tibial plateau. MATERIALS AND METHODS: A systematic literature search was performed using PubMed, EMBASE, and Cochrane Library to identify studies published through March 29, 2021, pertaining to balloon tibioplasty or conventional osteosynthesis techniques for type III fractures. Non-human studies, opinion or editorial pieces, systematic reviews, case series (< 5 patients), and articles published in a non-English language were excluded. Primary outcomes were Rasmussen clinical score, range of motion, and Knee Society Score (KSS). A Joanna Briggs Institute (JBI) risk of bias assessment was performed for all studies. RESULTS: A total of 95 studies were identified, with 10 studies (and 132 total patients) meeting inclusion criteria: 1 study focused on balloon tibioplasty, 8 studies reported outcomes following conventional osteosynthesis, and 1 study compared outcomes of the two techniques. Mean follow-up times varied widely, from 4 to 76.3 months. Where reported, balloon tibioplasty resulted in good to excellent functional outcomes as indicated by Rasmussen clinical scores (mean 28.3 in a case series; mean 28.9 in a randomized controlled trial) and range of motion (≥ 140° in both studies) 1-2 years following surgery. KSS was not reported consistently enough for comparison. Studies ranged from low to high risk of bias according to the JBI assessment. CONCLUSIONS: Balloon tibioplasty can lead to excellent functional outcomes in patients with depression fractures of the lateral tibial plateau. More research is needed to directly compare outcomes following treatment with balloon tibioplasty or conventional osteosynthesis techniques.


Asunto(s)
Fracturas de la Tibia , Fijación Interna de Fracturas/métodos , Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto , Rango del Movimiento Articular , Estudios Retrospectivos , Tibia , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Resultado del Tratamiento
10.
PLoS One ; 16(2): e0244685, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33566803

RESUMEN

Stable isotope analysis is an increasingly used molecular tool to reconstruct the diet and ecology of elusive primates such as unhabituated chimpanzees. The consumption of C4 plant feeding termites by chimpanzees may partly explain the relatively high carbon isotope values reported for some chimpanzee communities. However, the modest availability of termite isotope data as well as the diversity and cryptic ecology of termites potentially consumed by chimpanzees obscures our ability to assess the plausibility of these termites as a C4 resource. Here we report the carbon and nitrogen isotope values from 79 Macrotermes termite samples from six savanna woodland chimpanzee research sites across equatorial Africa. Using mixing models, we estimated the proportion of Macrotermes C4 plant consumption across savanna woodland sites. Additionally, we tested for isotopic differences between termite colonies in different vegetation types and between the social castes within the same colony in a subset of 47 samples from 12 mounds. We found that Macrotermes carbon isotope values were indistinguishable from those of C3 plants. Only 5 to 15% of Macrotermes diets were comprised of C4 plants across sites, suggesting that they cannot be considered a C4 food resource substantially influencing the isotope signatures of consumers. In the Macrotermes subsample, vegetation type and caste were significantly correlated with termite carbon values, but not with nitrogen isotope values. Large Macrotermes soldiers, preferentially consumed by chimpanzees, had comparably low carbon isotope values relative to other termite castes. We conclude that Macrotermes consumption is unlikely to result in high carbon isotope values in either extant chimpanzees or fossil hominins.


Asunto(s)
Isótopos de Carbono/análisis , Conducta Alimentaria/fisiología , Isópteros/metabolismo , África , Animales , Conducta Animal/fisiología , Carbono/metabolismo , Dieta , Ecología , Bosques , Pradera , Isópteros/química , Nitrógeno/metabolismo , Isótopos de Nitrógeno/análisis , Pan troglodytes/metabolismo , Plantas
11.
Injury ; 52(6): 1534-1538, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33097198

RESUMEN

INTRODUCTION: The early generations of proximal tibial locking plates demonstrated inferior results when compared to dual plating in bicondylar tibial plateau fractures with posteromedial fragments (PMF). Modern plates have multiple rows of locking screws and variable angle technology -which tote the ability to capture the PMF. The purpose of this study was to determine if the modern plates could capture the PMF in a large series of bicondylar tibial plateau fractures. MATERIALS & METHODS: Axial computer topography (CT) scans of 114 bicondylar tibial plateau fractures with PMF were analyzed. Five proximal tibia locking plates-in seven total configurations-were applied to radiopaque tibiae models. All possible screws were placed. Templates of screw trajectories were created based on the model CT scans. These were superimposed onto patient CT scan images to assess for screw penetration into the PMF. Number of screws fully within the PMF were recorded. Capture of the PMF was defined as having at least two screws within the fragment. RESULTS: On average, all plates were able to capture 81.6% of PMF with an average of 3.77 [95% Confidence Interval (CI): 3.47-4.07] screws. However, their ability to capture all fragments varied greatly, from 55.7%-95.2% in fixed angle constructs. Overall, variable angle constructs had a significantly higher capture rate (98.5% vs. 74.9%; p<0.0001) and more screws in the PMF (5.88 [95% CI: 5.58-6.17] vs 2.93 [95% CI: 2.62-3.24]; p<0.0001) when compared to fixed angle constructs. CONCLUSION: Newer generation locking plates vary greatly in their ability to capture the PMF. Variable angle technology dramatically increases the ability to capture the majority of PMFs. Prior biomechanical and clinical studies may yield substantially different results if repeated with these newer implants. Use of newer generation locked plates should not replace thorough preoperative planning.


Asunto(s)
Tibia , Fracturas de la Tibia , Placas Óseas , Fijación Interna de Fracturas , Humanos , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía
12.
J Med Entomol ; 46(3): 572-9, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19496429

RESUMEN

We demonstrate that the addition of bed bug, Cimex lectularius, alarm pheromone to desiccant formulations greatly enhances their effectiveness during short-term exposure. Two desiccant formulations, diatomaceous earth (DE) and Dri-die (silica gel), were applied at the label rate with and without bed bug alarm pheromone components, (E)-2-hexenal, (E)-2-octenal, and a (E)-2-hexenal:(E)-2-octenal blend. First-instar nymphs and adult females were subjected to 10-min exposures, and water loss rates were used to evaluate the response. Optimal effectiveness was achieved with a pheromone concentration of 0.01 M. With Dri-die alone, the water loss was 21% higher than in untreated controls, and water loss increased nearly two times with (E)-2-hexenal and (E)-2-octenal and three times with the (E)-2-hexenal: (E)-2-octenal blend. This shortened survival of first-instar nymphs from 4 to 1 d, with a similar reduction noted in adult females. DE was effective only if supplemented with pheromone, resulting in a 50% increase in water loss over controls with the (E)-2-hexenal:(E)-2-octenal blend, and a survival decrease from 4 to 2 d in first-instar nymphs. Consistently, the addition of the pheromone blend to desiccant dust was more effective than adding either component by itself or by using Dri-die or DE alone. Based on observations in a small microhabitat, the addition of alarm pheromone components prompted bed bugs to leave their protective harborages and to move through the desiccant, improving the use of desiccants for control. We concluded that short exposure to Dri-die is a more effective treatment against bed bugs than DE and that the effectiveness of the desiccants can be further enhanced by incorporation of alarm pheromone. Presumably, the addition of alarm pheromone elevates excited crawling activity, thereby promoting cuticular changes that increase water loss.


Asunto(s)
Chinches/efectos de los fármacos , Desecación , Control de Insectos/métodos , Feromonas/farmacología , Animales , Chinches/crecimiento & desarrollo , Tierra de Diatomeas , Femenino , Ninfa/efectos de los fármacos , Gel de Sílice , Dióxido de Silicio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA