Europace ; 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38938169

RESUMEN

BACKGROUND AND AIMS: Subclinical atrial fibrillation (AF) is associated with increased risk of progression to clinical AF, stroke, and cardiovascular death. We hypothesized that in pacemaker patients requiring dual-chamber rate-adaptive (DDDR) pacing, Closed Loop Stimulation (CLS) integrated into the circulatory control system through intracardiac impedance monitoring would reduce the occurrence of atrial high-rate episodes (AHREs) compared to conventional DDDR pacing. METHODS: Patients with sinus node dysfunctions (SND) and an implanted pacemaker or defibrillator were randomly allocated to dual-chamber CLS (n=612) or accelerometer-based DDDR pacing (n=598) and followed for 3 years. The primary endpoint was time to the composite endpoint of first AHRE lasting ≥6 minutes, stroke, or transient ischemic attack (TIA). All AHREs were independently adjudicated using intracardiac electrograms. RESULTS: The incidence of the primary endpoint was lower in the CLS arm (50.6%) than in the DDDR arm (55.7%), primarily due to the reduction in AHREs lasting between 6 hours and 7 days. Unadjusted site-stratified hazard ratio (HR) for CLS versus DDDR was 0.84 (95%-CI, 0.72-0.99; p=0.035). After adjusting for CHA2DS2-VASc score, the HR remained 0.84 (95%-CI, 0.71-0.99; p=0.033). In subgroup analyses, the incremental benefit of CLS was greatest in patients without atrioventricular block (HR, 0.76; p=0.006) and in patients without AF history (HR, 0.73; p=0.010). The contribution of stroke/TIA to the primary endpoint (1.3%) was low and not statistically different between study arms. CONCLUSIONS: Dual-chamber CLS in patients with SND is associated with a significantly lower AHRE incidence than conventional DDDR pacing.

2.
J Cardiovasc Electrophysiol ; 34(4): 947-956, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36709469

RESUMEN

INTRODUCTION: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds). METHODS AND RESULTS: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort. The TI decrease rate was defined as the percentage of rolling weeks with a continuously decreasing TI trend. The derivation cohort was used to determine a TI decrease rate threshold for a ≥99% specificity of arrhythmia prediction. The associated risk of VT/VF episodes was estimated in the validation cohort by dividing the available follow-up into 60-day assessment intervals. Analyses were performed separately for 1354 ICD and 1030 CRT-D patients. During a median follow-up of 2.0 years, 727 patients (30.4%) experienced 3298 confirmed VT/VF episodes. In the ICD group, a TI decrease rate of >60% was associated with a higher risk of VT/VF episode in a 60-day assessment interval (stratified hazard ratio, 1.42; 95% confidence interval (CI), 1.05-1.92; p = .023). The TI decrease preceded (40.8%) or followed (59.2%) the VT/VF episodes. In the CRT-D group, no association between TI decrease and VT/VF episodes was observed (p = .84). CONCLUSION: In our longitudinal analysis, TI decrease was associated with VT/VF episodes only in ICD patients. Preventive interventions may be difficult since episodes can occur before or after TI decrease.


Asunto(s)
Arritmias Cardíacas , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/terapia , Impedancia Eléctrica , Estudios Retrospectivos , Fibrilación Ventricular , Desfibriladores Implantables
3.
J Cardiovasc Electrophysiol ; 33(7): 1472-1479, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35499267

RESUMEN

INTRODUCTION: The Respiratory Disturbance Index (RDI) computed by an implantable cardioverter defibrillator (ICD) algorithm accurately identifies severe sleep apnea (SA). In the present analysis, we tested the hypothesis that RDI could also predict atrial fibrillation (AF) burden. METHODS: Patients with ejection fraction ≤35% implanted with an ICD were enrolled and followed up for 24 months. One month after implantation, patients underwent a polysomnographic study. The weekly mean RDI value was considered, as calculated during the entire follow-up period and over a 1-week period preceding the sleep study. The endpoints were as follows: daily AF burden of ≥5 min, ≥6 h, ≥23 h. RESULTS: Here, 164 patients had usable RDI values during the entire follow-up period. Severe SA (RDI ≥ 30 episodes/h) was diagnosed in 92 (56%) patients at the time of the sleep study. During follow-up, AF burden ≥ 5 min/day was documented in 70 (43%), ≥6 h/day in 48 (29%), and ≥23 h/day in 33 (20%) patients. Device-detected RDI ≥ 30 episodes/h at the time of the polygraphy, as well as the polygraphy-measured apnea hypopnea index ≥ 30 episodes/h, were not associated with the occurrence of the endpoints, using a Cox regression model. However, using a time-dependent model, continuously measured weekly mean RDI ≥ 30 episodes/h was independently associated with AF burden ≥ 5 min/day (hazard ratio [HR]: 2.13, 95% confidence interval [CI]: 1.24-3.65, p = .006), ≥6 h/day (HR: 2.75, 95% CI: 1.37-5.49, p = .004), and ≥23 h/day (HR: 2.26, 95% CI: 1.05-4.86, p = .037). CONCLUSIONS: In heart failure patients, ICD-diagnosed severe SA on follow-up data review identifies patients who are from two- to three-fold more likely to experience an AF episode, according to various thresholds of daily AF burden.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Síndromes de la Apnea del Sueño , Algoritmos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Insuficiencia Cardíaca/complicaciones , Humanos , Síndromes de la Apnea del Sueño/complicaciones , Síndromes de la Apnea del Sueño/diagnóstico , Síndromes de la Apnea del Sueño/terapia
4.
Medicina (Kaunas) ; 59(1)2022 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-36676690

RESUMEN

Background. Data on leadless pacemaker (LPM) implantation in an emergency setting are currently lacking. Objective. We aimed to investigate the feasibility of LPM implantation for emergency bradyarrhythmia, in patients referred for urgent PM implantation, in a large, multicenter, real-world cohort of LPM recipients. Methods. Two cohorts of LPM patients, stratified according to the LPM implantation scenario (patients admitted from the emergency department (ED+) vs. elective patients (ED−)) were retrieved from the iLEAPER registry. The primary outcome of the study was a comparison of the peri-procedural complications between the groups. The rates of peri-procedural characteristics (overall procedural and fluoroscopic duration) were deemed secondary outcomes. Results. A total of 1154 patients were enrolled in this project, with patients implanted due to an urgent bradyarrhythmia (ED+) representing 6.2% of the entire cohort. Slow atrial fibrillation and complete + advanced atrioventricular blocks were more frequent in the ED+ cohort (76.3% for ED+ vs. 49.7% for ED−, p = 0.025; 37.5% vs. 27.3%, p = 0.027, respectively). The overall procedural times were longer in the ED+ cohort (60 (45−80) mins vs. 50 (40−65) mins, p < 0.001), showing higher rates of temporary pacing (94.4% for ED+ vs. 28.9% for ED−, p < 0.001). Emergency LPM implantation was not correlated with an increase in the rate of major complications compared to the control group (6.9% ED+ vs. 4.2% ED−, p = 0.244). Conclusion. LPM implantation is a feasible procedure for the treatment of severe bradyarrhythmia in an urgent setting. Urgent LPM implantation was not correlated with an increase in the rate of major complications compared to the control group, but it was associated with longer procedural times.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Humanos , Bradicardia/terapia , Fibrilación Atrial/terapia , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 32(9): 2528-2535, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34252991

RESUMEN

INTRODUCTION: Factors influencing malignant arrhythmia onset are not fully understood. We explored the circadian periodicity of ventricular arrhythmias (VAs) in patients with implantable cardioverter and cardiac resynchronization defibrillators (ICD/CRT-D). METHODS: Time, morphology (monomorphic/polymorphic), and mode of termination (anti-tachycardia pacing [ATP] or shock) of VAs stored in a database of remote monitoring data were adjudicated. Episodes were grouped in six 4-h timeslots from 00:00 to 24:00. Circadian distributions and adjusted marginal odds ratios (ORs), with 95% confidence interval (CI), were analyzed using mixed-effect models and logit generalized estimating equations, respectively, to account for within-subject correlation of multiple episodes. RESULTS: Among 1303 VA episodes from 446 patients (63% ICD and 37% CRT-D), 120 (9%) self-extinguished, and 842 (65%) were terminated by ATP, 343 (26%) by shock. VAs clustered from 08:00 to 16:00 with 44% of episodes, as compared with 22% from 00:00 to 08:00 (p < .001) and 34% from 16:00 to 24:00 (p = .005). Episodes were more likely to be polymorphic at night with an adjusted marginal OR of 1.66 (CI, 1.15-2.40; p = .007) at 00:00-04:00 versus other timeslots. Episodes were less likely to be terminated by ATP in the 00:00-04:00 (success-to-failure ratio, 0.67; CI, 0.46-0.98; p = .039) and 08:00-12:00 (0.70; CI, 0.51-0.96; p = .02) timeslots, and most likely to be terminated by ATP between 12:00 and 16:00 (success-to-failure ratio 1.42; CI, 1.06-1.91; p = .02). CONCLUSION: VAs did not distribute uniformly over the 24 h, with a majority of episodes occurring from 08:00 to 16:00. Nocturnal episodes were more likely to be polymorphic. The efficacy of ATP depended on the time of delivery.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado del Tratamiento
6.
J Cardiovasc Electrophysiol ; 30(9): 1626-1635, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31165517

RESUMEN

INTRODUCTION: Clinical trials did not provide conclusive evidence concerning the benefit of prophylactic implantable cardioverter-defibrillators (ICDs) in patients with severe nonischemic cardiomyopathy (NICM). We aimed to compare incidence of appropriate sustained ventricular arrhythmia (SVA) and device therapy in ischemic cardiomyopathy (ICM) vs NICM ICD and/or cardiac resynchronization therapy (CRT-D) patients. METHODS AND RESULTS: We analyzed remote-monitoring data from devices of the Home Monitoring Expert Alliance network. SVA recordings were adjudicated by three independent electrophysiologists. Our cohort included 1,946 patients who received either an ICD (55%) or a CRT-D (45%) for primary prevention of sudden cardiac death. Median (interquartile range) age was 70 (62-77) years, 81% were male, and 52% were in the ICM group. Patients were remotely monitored for a maximum follow-up of 5 years. The 5-year product-limit estimate of SVA incidence in patients with an ICD was 47.3% (95% confidence interval [CI], 41.0%-53.9%) in the ICM group and 44.7% (36.9%-53.3%) in the NICM group. In patients with a CRT-D, SVA incidence was 45.7% (37.3%-55.0%) in ICM patients and 49.2% (40.4%-58.7%) in NICM patients. The adjusted hazard ratio for SVA in the ICM vs NICM group was 0.96 (95% CI: 0.70-1.30, P = .77) in ICD patients and 0.85 (95% CI: 0.61-1.18, P = .34) in CRT-D patients. SVAs triggered appropriate device therapies with similar incidence in all groups. CONCLUSION: In a large cohort of remotely monitored ICD and CRT-D recipients, SVA incidence did not significantly differ in ICM and NICM patients.


Asunto(s)
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Cardiomiopatías/fisiopatología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Prevención Primaria/instrumentación , Tecnología de Sensores Remotos , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Cardiomiopatías/diagnóstico , Cardiomiopatías/mortalidad , Causas de Muerte , Bases de Datos Factuales , Muerte Súbita Cardíaca/epidemiología , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Humanos , Incidencia , Italia/epidemiología , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidad , Isquemia Miocárdica/fisiopatología , Valor Predictivo de las Pruebas , Falla de Prótesis , Factores de Riesgo , Procesamiento de Señales Asistido por Computador , Factores de Tiempo , Resultado del Tratamiento
7.
Europace ; 21(12): 1890-1899, 2019 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-31665280

RESUMEN

AIMS: Female sex is considered an independent risk factor of transvenous leads extraction (TLE) procedure. The aim of the study was to evaluate the effectiveness of TLE in women compared with men. METHODS AND RESULTS: A post hoc analysis of risk factors and effectiveness of TLE in women and men included in the ESC-EHRA EORP ELECTRa registry was conducted. The rate of major complications was 1.96% in women vs. 0.71% in men; P = 0.0025. The number of leads was higher in men (mean 1.89 vs. 1.71; P < 0.0001) with higher number of abandoned leads in women (46.04% vs. 34.82%; P < 0.0001). Risk factors of TLE differed between the sexes, of which the major were: signs and symptoms of venous occlusion [odds ratio (OR) 3.730, confidence interval (CI) 1.401-9.934; P = 0.0084], cumulative leads dwell time (OR 1.044, CI 1.024-1.065; P < 0.001), number of generator replacements (OR 1.029, CI 1.005-1.054; P = 0.0184) in females and the number of leads (OR 6.053, CI 2.422-15.129; P = 0.0001), use of powered sheaths (OR 2.742, CI 1.404-5.355; P = 0.0031), and white blood cell count (OR 1.138, CI 1.069-1.212; P < 0.001) in males. Individual radiological and clinical success of TLE was 96.29% and 98.14% in women compared with 98.03% and 99.21% in men (P = 0.0046 and 0.0098). CONCLUSION: The efficacy of TLE was lower in females than males, with a higher rate of periprocedural major complications. The reasons for this difference are probably related to disparities in risk factors in women, including more pronounced leads adherence to the walls of the veins and myocardium. Lead management may be key to the effectiveness of TLE in females.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Remoción de Dispositivos , Complicaciones Intraoperatorias/epidemiología , Complicaciones Posoperatorias/epidemiología , Infecciones Relacionadas con Prótesis/terapia , Anciano , Anciano de 80 o más Años , Suministros de Energía Eléctrica , Europa (Continente) , Femenino , Humanos , Recuento de Leucocitos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Marcapaso Artificial , Sistema de Registros , Factores Sexuales , Factores de Tiempo , Insuficiencia de la Válvula Tricúspide/epidemiología , Trombosis de la Vena/epidemiología
8.
Heart Rhythm ; 20(10): 1429-1435, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37481220

RESUMEN

BACKGROUND: The impact of sex in clinical and procedural outcomes in leadless pacemaker (LPM) patients has not yet been investigated. OBJECTIVE: The purpose of this study was to investigate sex-related differences in patients undergoing LPM implantation. METHODS: Consecutive patients enrolled in the i-LEAPER registry were analyzed. Comparisons between sexes were performed within the overall cohort using an adjusted analysis with 1:1 propensity matching for age and comorbidities. The primary outcome was the comparison of major complication rates. Sex-related differences regarding electrical performance and all-cause mortality during follow-up were deemed secondary outcomes. RESULTS: In the overall population (n = 1179 patients; median age 80 years), 64.3% were men. After propensity matching, 738 patients with no significant baseline differences among groups were identified. During median follow-up of 25 [interquartile range 24-39] months, female sex was not associated with LPM-related major complications (hazard ratio [HR] 2.03; 95% confidence interval [CI] 0.70-5.84; P = .190) or all-cause mortality (HR 0.98; 95% CI 0.40-2.42; P = .960). LPM electrical performance results were comparable between groups, except for a higher pacing impedance in women at implant and during follow-up (24 months: 670 [550-800] Ω vs 616 [530-770] Ω; P = .014) that remained within normal limits. CONCLUSION: In a real-world setting, we found differences in sex-related referral patterns for LPM implantation with an underrepresentation of women, although major complication rate and LPM performance were comparable between sexes. Female patients showed higher impedance values, which had no impact on overall device performance. Electrical parameters remained within normal limits in both groups during the entire follow-up.

9.
Heart Rhythm ; 20(3): 395-404, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36496135

RESUMEN

BACKGROUND: Limited data on the real-world safety and efficacy of leadless pacemakers (LPMs) post-transvenous lead extraction (TLE) are available. OBJECTIVE: The purpose of this study was to assess the long-term safety and effectiveness of LPMs following TLE in comparison with LPMs de novo implantation. METHODS: Consecutive patients who underwent LPM implantation in 12 European centers joining the International LEAdless PacemakEr Registry were enrolled. The primary end point was the comparison of LPM-related complication rate at implantation and during follow-up (FU) between groups. Differences in electrical performance were deemed secondary outcomes. RESULTS: Of the 1179 patients enrolled, 15.6% underwent a previous TLE. During a median FU of 33 (interquartile range 24-47) months, LPM-related major complications and all-cause mortality did not differ between groups (TLE group: 1.6% and 5.4% vs de novo group: 2.2% and 7.8%; P = .785 and P = .288, respectively). Pacing threshold (PT) was higher in the TLE group at implantation and during FU, with very high PT (>2 V@0.24 ms) patients being more represented than in the de novo implantation group (5.4% vs 1.6 %; P = .004). When the LPM was deployed at a different right ventricular (RV) location than the one where the previous transvenous RV lead was extracted, a lower proportion of high PT (>1-2 V@0.24 ms) patients at implantation, 1-month FU, and 12-month FU (5.9% vs 18.2%, P = .012; 3.4% vs 12.9%, P = .026; and 4.3% vs 14.5%, P = .037, respectively) was found. CONCLUSION: LPMs showed a satisfactory safety and efficacy profile after TLE. Better electrical parameters were obtained when LPMs were implanted at a different RV location than the one where the previous transvenous RV lead was extracted.


Asunto(s)
Marcapaso Artificial , Humanos , Resultado del Tratamiento , Marcapaso Artificial/efectos adversos , Estimulación Cardíaca Artificial/efectos adversos , Sistema de Registros , Diseño de Equipo
10.
Int J Cardiol ; 371: 197-203, 2023 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-36115442

RESUMEN

BACKGROUND: Age-related differences on leadless pacemaker (LP) are poorly described. Aim of this study was to compare clinical indications, periprocedural and mid-term device-associated outcomes in a large real-world cohort of LP patients, stratified by age at implantation. METHODS: Two cohorts of younger and older patients (≤50 and > 50 years old) were retrieved from the iLEAPER registry. The primary outcome was to compare the underlying indication why a LP was preferred over a transvenous PM across the two cohorts. Rates of peri-procedural and mid-term follow-up major complications as well as LP electrical performance were deemed secondary outcomes. RESULTS: 1154 patients were enrolled, with younger patients representing 6.2% of the entire cohort. Infective and vascular concerns were the most frequent characteristics that led to a LP implantation in the older cohort (45.8% vs 67.7%, p < 0.001; 4.2% vs 16.4%, p = 0.006), while patient preference was the leading cause to choose a LP in the younger (47.2% vs 5.6%, p < 0.001). Median overall procedural (52 [40-70] vs 50 [40-65] mins) and fluoroscopy time were similar in both groups. 4.3% of patients experienced periprocedural complications, without differences among groups. Threshold values were higher in the younger, both at discharge and at last follow-up (0.63 [0.5-0.9] vs 0.5 [0.38-0-7] V, p = 0.004). CONCLUSION: When considering LP indications, patient preference was more common in younger, while infective and vascular concerns were more frequent in the older cohort. Rates of device-related complications did not differ significantly. Younger patients tended to have a slightly higher pacing threshold at mid-term follow-up.


Asunto(s)
Marcapaso Artificial , Humanos , Persona de Mediana Edad , Resultado del Tratamiento , Diseño de Equipo , Marcapaso Artificial/efectos adversos , Factores de Tiempo , Estimulación Cardíaca Artificial/efectos adversos
11.
Heart Rhythm ; 20(2): 233-240, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-37283031

RESUMEN

BACKGROUND: Elevated resting heart rate is a risk factor for cardiovascular events. OBJECTIVE: The purpose of this study was to investigate the clinical significance of nocturnal heart rate (nHR) and 24-hour mean heart rate (24h-HR) obtained by continuous remote monitoring (RM) of implantable devices. METHODS: We analyzed daily-sampled trends of nHR, 24h-HR, and physical activity in patients on ß-blocker therapy for chronic heart failure and with implantable cardioverter-defibrillators or cardiac resynchronization therapy defibrillators (CRT-Ds). Patients were grouped by average nHR and 24h-HR quartile during follow-up to estimate the respective incidence of nonarrhythmic death and device-treated ventricular tachycardia/fibrillation (VT/VF). RESULTS: The study cohort included 1330 patients (median age 69 years [interquartile range 61-77 years]; 41% [n = 550] with CRT-D; median follow-up 25 months [interquartile range 13-42 months]). Compared with patients in the lowest nHR quartile (≤57 beats/min) group, patients in the highest quartile group (>65 beats/min) had an increased risk of nonarrhythmic death (adjusted hazard ratio [AHR] 2.25; 95% confidence interval [CI] 1.13-4.50; P = .021) and VT/VF (AHR 1.98; 95% CI 1.40-2.79; P < .001) and were characterized by the lowest level of physical activity (P ≤ .0004 vs every other nHR quartiles). The highest 24h-HR quartile group (>75 beats/min) showed an increased risk of VT/VF (AHR 2.13; 95% CI 1.52-2.99; P < .001) and a weaker though significant association with nonarrhythmic mortality (AHR 1.80; 95% CI 1.00-3.22; P = .05) as compared with the lowest 24h-HR quartile group (≤65 beats/min). CONCLUSION: In remotely monitored patients with implantable cardioverter-defibrillator/CRT-D on ß-blocker therapy for heart failure, elevated heart rates (nHR >65 beats/min and 24h-HR >75 beats/min) were associated with increased mortality and VT/VF risk. nHR showed a stronger association than 24h-HR with worst prognosis and lowest physical activity.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Taquicardia Ventricular , Disfunción Ventricular Izquierda , Humanos , Persona de Mediana Edad , Anciano , Frecuencia Cardíaca , Pronóstico , Volumen Sistólico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia , Arritmias Cardíacas/terapia , Factores de Riesgo , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables/efectos adversos , Disfunción Ventricular Izquierda/complicaciones
12.
J Interv Card Electrophysiol ; 64(3): 607-619, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34709504

RESUMEN

PURPOSE: The purpose of this study was to assess the available mortality risk stratification models for implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy defibrillator (CRT-D) patients. METHODS: We conducted a review of mortality risk stratification models and tested their ability to improve prediction of 1-year survival after implant in a database of patients who received a remotely controlled ICD/CRT-D device during routine care and included in the independent Home Monitoring Expert Alliance registry. RESULTS: We identified ten predicting models published in peer-reviewed journals between 2000 and 2021 (Parkash, PACE, MADIT, aCCI, CHA2DS2-VASc quartiles, CIDS, FADES, Sjoblom, AAACC, and MADIT-ICD non-arrhythmic mortality score) that could be tested in our database as based on common demographic, clinical, echocardiographic, electrocardiographic, and laboratory variables. Our cohort included 1,911 patients with left ventricular dysfunction (median age 71, 18.3% female) from sites not using any risk stratification score for systematic patient screening. Patients received an ICD (53.8%) or CRT-D (46.2%) between 2011 and 2017, after standard physician evaluation. There were 56 deaths within 1-year post-implant, with an all-cause mortality rate of 2.9% (95% confidence interval [CI], 2.3-3.8%). Four predicting models (Parkash, MADIT, AAACC, and MADIT-ICD non-arrhythmic mortality score) were significantly associated with increased risk of 1-year mortality with hazard ratios ranging from 3.75 (CI, 1.31-10.7) to 6.53 (CI 1.52-28.0, p ≤ 0.014 for all four). Positive predictive values of 1-year mortality were below 25% for all models. CONCLUSION: In our analysis, the models we tested conferred modest incremental predicting power to ordinary screening methods.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Terapia de Resincronización Cardíaca/métodos , Dispositivos de Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables/efectos adversos , Femenino , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
13.
JACC Clin Electrophysiol ; 8(12): 1553-1562, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36543505

RESUMEN

BACKGROUND: Causes of sex differences in incidence of sustained ventricular arrhythmias (SVAs) are poorly understood. OBJECTIVES: This study aims to investigate sex-specific risk of SVAs and device therapies by balancing sex groups in relation to several baseline characteristics with the propensity score (PS). METHODS: We used a large remote monitoring dataset from implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds). Study endpoints were time to the first appropriate SVA, time to the first device therapy for SVA, and time to the first ICD shock. Results were compared between females and a PS-matched male subgroup. RESULTS: In a cohort of 2,532 patients with an ICD or CRT-D (median age, 70 years), 488 patients (19.3%) were women. After selecting 488 men PS-matched for 19 variables relative to baseline demographics, implant indications, principal comorbidities, and concomitant therapy, yet the SVA rate at the 2.1-year median follow-up was significantly lower in women than in man (adjusted HR: 0.65; 95% CI: 0.51-0.81; P < 0.001). Women also showed a reduced risk of any device therapy (HR: 0.59; 95% CI: 0.45-0.76; P < 0.001) and shocks (HR: 0.66; 95% CI: 0.47-0.94; P = 0.021). Differences in sex-specific SVA risk profile were not confirmed in CRT-D patients (HR: 0.78; 95% CI: 0.55-1.09; P = 0.14) nor in those with an ejection fraction <30% (HR: 0.80; 95% CI: 0.52-1.23; P = 0.31). CONCLUSIONS: After matching demographics, indications, principal comorbidities, and concomitant therapy, women still exhibited a lower SVA risk profile than men, except in the subgroups of CRT-D or/and ejection fraction <30%.


Asunto(s)
Desfibriladores Implantables , Humanos , Masculino , Femenino , Anciano , Desfibriladores Implantables/efectos adversos , Puntaje de Propensión , Resultado del Tratamiento , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Cardioversión Eléctrica
14.
Heart Rhythm ; 18(3): 374-381, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33283757

RESUMEN

BACKGROUND: Sleep apnea, as measured by polysomnography, is associated with adverse outcomes in heart failure. The DASAP-HF (Diagnosis and Treatment of Sleep Apnea in Patient With Heart Failure) study previously demonstrated that the respiratory disturbance index (RDI) computed by the ApneaScan algorithm (Boston Scientific) accurately identifies severe sleep apnea in implantable cardioverter-defibrillator (ICD) patients. OBJECTIVE: The purpose of the long-term study phase was to assess the incidence of clinical events after 24 months and investigate the association with RDI values. METHODS: Patients with left ventricular ejection fraction ≤35% implanted with an ICD were enrolled and followed-up for 24 months. The RDI calculated at 1 month after implantation was used to stratify patients (below or above 30 episodes/h). The endpoints were all-cause death and a combination of all-cause death or cardiovascular hospitalization. RESULTS: Of the 265 enrolled patients, 224 had usable RDI values. Severe sleep apnea (RDI ≥30 episodes/h) was diagnosed in 115 patients (51%). These patients were more frequently male (84% vs 72%; P = .030) and had higher creatinine levels. During median follow-up of 25 months, 19 patients (8%) died. Cardiovascular hospitalizations were reported in 19 patients (8%). The risk of all-cause death was higher in patients with RDI ≥30 episodes/h (hazard ratio [HR] 3.33; 95% confidence interval [CI] 1.35-8.21; P = .023), as well as the risk of all-cause death or cardiovascular hospitalization (HR 1.94; 95% CI 1.01-3.76; P = .048). At multivariate analysis, independent predictors of death were RDI ≥30 episodes/h (HR 4.02; 95% CI 1.16-13.97; P = .029) and creatinine levels (HR 2.36; 95% CI 1.26-4.42; P = .008). CONCLUSION: In heart failure patients implanted with an ICD, higher RDI values are associated with death and cardiovascular hospitalizations. Device-detected severe sleep apnea independently predicts death.


Asunto(s)
Algoritmos , Desfibriladores Implantables , Diagnóstico por Computador/métodos , Insuficiencia Cardíaca/terapia , Síndromes de la Apnea del Sueño/diagnóstico , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología , Anciano , Femenino , Estudios de Seguimiento , Francia/epidemiología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Incidencia , Italia/epidemiología , Masculino , Polisomnografía , Estudios Prospectivos , Factores de Riesgo , Síndromes de la Apnea del Sueño/fisiopatología , Tasa de Supervivencia/tendencias , Factores de Tiempo
15.
ESC Heart Fail ; 8(6): 5204-5212, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34514741

RESUMEN

AIMS: There are conflicting data on the benefit of cardiac resynchronization therapy (CRT) in heart failure (HF) patients with permanent atrial fibrillation (AF). We aimed to compare patient outcomes according to the presence or absence of permanent AF at device implantation. METHODS AND RESULTS: We retrospectively analysed remote monitoring data from 1141 CRT defibrillators. Propensity score with inverse-probability weighting method was used to balance AF and sinus rhythm (SR) groups. Analysis endpoints included total mortality, appropriate defibrillation shocks, and CRT percentage. There were 229 patients (20.1%) in the AF group and 912 patients (79.9%) in the SR group. Compared with SR patients, AF patients were older (median age, 77 vs. 72 years, P < 0.001), more frequently male (82.5% vs. 75.5%, P = 0.02), and had higher heart rate (75.7 vs. 71.0 b.p.m., P < 0.001). Of the 229 AF patients, 162 (70.7%) received suboptimal CRT (<98%) and 67 (29.3%) had adequate CRT (≥98%). During a median follow-up of 24 months, total mortality did not differ between AF and SR groups (propensity-score-weighted hazard ratio, HR 1.32 [95% confidence interval, 0.82-2.15], P = 0.25). The risk of appropriate shocks was significantly higher in the AF group with <98% CRT than in the SR group (weighted-HR, 1.99 [1.21-3.26], P = 0.006) and was similar in the AF group with ≥98% CRT versus the SR group (1.29 [0.66-2.53], P = 0.45). During follow-up, sinus rhythm was recovered in 23 patients in the AF group (10%) after a median time of 106 (42-256) days. The rate of sinus rhythm recovery in the AF group was 4.5 (95% CI, 2.8-6.7) per 100 patient-years; the rate of permanent AF occurrence in the SR group was 2.5 (95% CI, 1.9-3.3) per 100 patient-years. CONCLUSIONS: Although mortality was similar across patient groups, patients with permanent AF and suboptimal CRT had twofold higher risk of appropriate shocks than SR patients or AF patients with CRT ≥ 98%.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Anciano , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Terapia de Resincronización Cardíaca/métodos , Desfibriladores , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
16.
Int J Cardiol ; 305: 76-81, 2020 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-32046909

RESUMEN

BACKGROUND: Continuous monitoring by implantable loop recorder (ILR) can provide information relevant to rhythm control and oral anticoagulation (OAC) after atrial fibrillation (AF) ablation, but there is little agreement on patients' selection and appropriate management strategy. METHODS: An expert panel (EP) made up of eight Italian electrophysiologists with expertise in AF ablation, gathered to define an algorithm to guide continuous rhythm monitoring in AF patients who have undergone ablation. The process included a review of the current literature and two EP face-to-face meetings. Between the two meetings, an on-line survey was sent to 50 Italian electrophysiologists practicing AF ablation. Agreement level was considered reached when ≥70% of respondents agreed or were neutral. RESULTS: Two algorithms were developed to define patients for whom the ILR would be suggested support for (OAC) therapy discontinuation and rhythm management after AF ablation. Thirty-three out of 50 physicians responded to on-line survey (66% response rate). Together with EP members the responders accounted for electrophysiology centers performing about 50% of total yearly Italian AF ablation procedures. Agreement level was reached at the first survey round on all the questions, so the algorithms were not further modified and re-tested. CONCLUSIONS: EP developed two algorithms for ECG monitoring to guide OAC therapy discontinuation and rhythm management after AF ablation. These suggestions, validated by wide feedback and consensus of physicians performing AF ablations, might support the decision on the choice and the use of ECG monitoring techniques, based on specific patient characteristics.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Electrocardiografía Ambulatoria , Testimonio de Experto , Humanos , Italia/epidemiología , Resultado del Tratamiento
17.
J Arrhythm ; 36(2): 353-362, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32256887

RESUMEN

BACKGROUND: Parameters measured during implantable cardioverter defibrillator (ICD) implant also depend on bioelectrical properties of the myocardium. We aimed to explore their potential association with clinical outcomes in patients with single/dual-chamber ICD and cardiac resynchronization therapy defibrillator (CRT-D). METHODS: In the framework of the Home Monitoring Expert Alliance, baseline electrical parameters for all implanted leads were compared by the occurrence of all-cause mortality, adjudicated ventricular arrhythmia (VA), and atrial high-rate episode lasting ≥24 hours (24 h AHRE). RESULTS: In a cohort of 2976 patients (58.1% ICD) with a median follow-up of 25 months, event rates were 3.1/100 patient-years for all-cause mortality, 18.1/100 patient-years for VA, and 9.3/100 patient-years for 24 h AHRE. At univariate analysis, baseline shock impedance was consistently lower in groups with events than without, with a 40 Ω cutoff that better identified high-risk patients. However, at multivariable analysis, the adjusted-hazard ratios (HRs) lost statistical significance for any endpoint. Baseline atrial sensing amplitude during sinus rhythm was lower in patients with 24 h AHRE than in those without (2.45 [IQR: 1.65-3.85] vs 3.51 [IQR: 2.37-4.67] mV, P < .01). The adjusted HR for 24 h AHRE in patients with atrial sensing >1.5 mV vs those with values ≤1.5 mV was 0.52 (95% CI: 0.33-0.83), P = .006. CONCLUSIONS: Although lower baseline shock impedance was observed in patients with events, the association lost statistical significance at multivariable analysis. Conversely, low sinus rhythm atrial sensing (≤1.5 mV) measured with standard transvenous leads could identify subjects at high risk of atrial arrhythmia.

18.
Clin Cardiol ; 42(1): 76-83, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30421438

RESUMEN

BACKGROUND: This survey aimed to describe the organizational workflow of cardiac implantable electronic devices (CIEDs) remote monitoring (RM) service in ordinary practice. METHODS: A questionnaire was designed for our purpose and completed by 49 sites participating to the Italian Home Monitoring Expert Alliance. RESULTS: A dedicated organizational model for RM was set up for 86% of centers. The median RM team consisted of 2 (Interquartile range [IQR]: 1-3) physicians and 1 (IQR: 0-2) nurse. RM service was available in working hours and the median percentage of patients included was 100% (IQR: 10%-100%) for implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy (CRT) recipients and 5% (IQR:0%-30%) for pacemakers. In-office follow-up was performed every 12 and 6 months for pacemaker and ICD/CRT recipients, respectively. More than 90% of sites used to activate all technical alerts, with a prompt reaction in case of an out-of-range parameter. The threshold for atrial fibrillation (AF) daily burden notification in most cases ranged from 2.4 to 7.2 hours. All ventricular arrhythmias alerts were usually switched on: an inappropriate therapy or more than one appropriate episode triggered an urgent in-hospital visit. Concerning heart failure, low CRT percentage pacing alert was always used, while the other available notifications were less frequently switched on. CONCLUSIONS: This survey showed that RM service was usually set up with a primary nursing model including on average two responsible physicians and one nurse and mainly offered to ICD/CRT patients. Technical, AF and ventricular arrhythmia alerts triggered prompt reactions, while heart failure related indexes were generally less applied.


Asunto(s)
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Modelos Organizacionales , Monitoreo Ambulatorio/métodos , Encuestas y Cuestionarios , Telemedicina/organización & administración , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Italia , Masculino
19.
J Cardiovasc Med (Hagerstown) ; 20(3): 114-121, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30575601

RESUMEN

INTRODUCTION: Implantable cardioverter-defibrillator (ICD) alarm systems are an important means of monitoring device functioning. The aim of this study was to compare the ability of patients with sense two types of device alert systems: an audible alert and a vibratory alarm. METHODS: The ability to recognize the alarms was assessed in three alarm tests performed in a series of consecutive ICD patients enrolled during routine outpatient device follow-up. To avoid overestimating the rate of patients able to sense the alarm, the first test was performed without forewarning. Subsequently, the second test was performed after the patients had been forewarned. Finally, to assess the learning effect of a demonstration test, a third test was performed, again without forewarning. RESULTS: A total of 528 patients (65.4 ±â€Š14.4 years, 74.6% male) were enrolled: 347 (65.7%) with an audible alert-endowed device and 181 (34.3%) with a vibratory alarm-endowed device. When emitted without warning, the alarms were sensed by 72.4% of patients. When patients were forewarned, the probability of sensing the alarms rose to 92.5% (P < 0.001). In both cases, the vibratory alarm was more likely to be sensed than the audible alert (77.3 vs. 67.7% in the first case; 96.1 vs. 87.9% in the second case; all P < 0.05). CONCLUSION: ICD alarms emitted in an outpatient setting are sensed by a large proportion of patients, but not by all. Training patients by means of demonstration tests significantly increases the rate of patients who recognize the alarm. Vibratory alarm seems to be more effective than audible alert.


Asunto(s)
Estimulación Acústica , Alarmas Clínicas , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Estimulación Física , Falla de Prótesis , Anciano , Percepción Auditiva , Cardioversión Eléctrica/efectos adversos , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Umbral Sensorial , Detección de Señal Psicológica , Vibración
20.
Int J Cardiol ; 275: 104-106, 2019 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-30327133

RESUMEN

BACKGROUND: The occurrence of sustained ventricular arrhythmias (SVA) may be influenced by environmental factors. We aimed to investigate annual periodic trends of SVA from the intracardiac electrograms (IEGMs) stored in the implantable defibrillators (ICDs) or cardiac resynchronization therapy (CRT-D) recipients. METHODS: Data from the Home Monitoring Expert Alliance project, a pooled repository of remote monitoring transmissions were analyzed. All IEGMs stored were independently adjudicated by three cardiac electrophysiologists. Periodicity of SVA was evaluated with Generalized Estimating Equations (GEE) models, including periodic terms depending on months in a year. RESULTS: A total of 2936 ICD/CRT-D patients (median age 70 years, 79.6% male) were followed for a median period of 25[13-44] months. Most prevalent structural heart diseases were ischemic (50.8%) and idiopathic dilated (30.6%) cardiomyopathies. Overall, 942 (32.1%) patients experienced a total of 4824 SVA. At GEE analysis, we found a significant periodic component (p = 0.048) when considering both shocked and non-shocked episodes. SVA less frequently occurred in Junes and Julies (3.7 × 1000 patient-month). No evidence of significant periodicity was collected in the subgroup of ischemic patients. CONCLUSIONS: In this RM-based cohort of ICD/CRT-T patients, we observed an annual periodicity of SVA occurrence, with a lower incidence in summer months.


Asunto(s)
Desfibriladores Implantables , Técnicas Electrofisiológicas Cardíacas/métodos , Sistema de Registros , Estaciones del Año , Taquicardia Ventricular/epidemiología , Telemetría/estadística & datos numéricos , Anciano , Femenino , Humanos , Incidencia , Italia/epidemiología , Masculino , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/terapia