Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Shoulder Elbow Surg ; 33(5): 1004-1016, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38286183

RESUMEN

BACKGROUND: Previously, we reported early (2-year) findings from a randomized controlled trial comparing a second-generation uncemented trabecular metal-backed (TM) glenoid vs. cemented polyethylene glenoid (POLY) in patients undergoing a total shoulder arthroplasty. The purpose of the current study is to report disease-specific quality of life, clinical, patient-reported, and radiographic outcomes at midterm (5-year) from this trial. METHODS: Five surgeons from 3 centers participated. Patients 18-79 years with a primary diagnosis of glenohumeral osteoarthritis were screened for eligibility. Randomization to an uncemented TM or cemented POLY glenoid was performed intra-operatively after adequate bone stock was confirmed. Study intervals were baseline, 2- and 5-year postoperative. The primary outcome was the Western Ontario Osteoarthritis Shoulder (WOOS) quality of life score. Secondary outcomes included the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form, EuroQol-5 Dimensions, and 12-Item Short Form Health Survey scores and clinical and radiographic examinations. Radiographic images were reviewed for metal debris according to Endrizzi. Mixed effects repeated measures analysis of variance for within- and between-group comparisons were performed. RESULTS: Of the 104 patients who consented, 93 were randomized (46 TM; 47 POLY). There were no differences between groups at baseline (TM: mean age 66.5 years [standard deviation (SD) 6.4], 24 male and 22 female; and POLY: mean age 68.4 years [SD 5.5], 23 male / 24 female). Mean (SD) WOOS scores at baseline and 2 and 5 years were as follows: TM, 32 (21), 92 (13), and 93 (11); POLY, 27 (15), 93 (11), and 93 (10), respectively. No statistical or clinically relevant differences were noted with patient-reported outcomes between groups. Metal debris was observed in 11 (23.9%) patients, but outcomes were not negatively impacted, and debris severity was minor (grades 1 and 2). Complication rates were similar between groups (TM: 7 of 46 [15.2%], and POLY: 8 of 47 [17.0%]; P = .813). No aseptic glenoid failures were reported, but 1 patient in the TM group required revision because of infection. CONCLUSIONS: Our short-term (2-year) findings were maintained with longer follow-up. At 5 years postoperation, there were no statistically or clinically significant differences between an uncemented second-generation TM glenoid and a cemented polyethylene glenoid with respect to disease-specific quality of life or patient-reported outcomes. No glenoid implant failures were reported, and complication rates were similar between groups. Only one complication was glenoid related (1 infection in the TM group). Metal debris was observed in 23.9% of patients with a TM glenoid but did not negatively influence implant survival, patient-reported outcomes, or shoulder function.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Artroplastia de Reemplazo , Prótesis Articulares , Osteoartritis , Articulación del Hombro , Humanos , Masculino , Femenino , Anciano , Artroplastía de Reemplazo de Hombro/métodos , Polietileno , Artroplastia de Reemplazo/métodos , Calidad de Vida , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Resultado del Tratamiento , Osteoartritis/diagnóstico por imagen , Osteoartritis/cirugía , Metales , Diseño de Prótesis , Estudios de Seguimiento , Estudios Retrospectivos
2.
Bone Jt Open ; 2(9): 728-736, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34488426

RESUMEN

AIMS: To report early (two-year) postoperative findings from a randomized controlled trial (RCT) investigating disease-specific quality of life (QOL), clinical, patient-reported, and radiological outcomes in patients undergoing a total shoulder arthroplasty (TSA) with a second-generation uncemented trabecular metal (TM) glenoid versus a cemented polyethylene glenoid (POLY) component. METHODS: Five fellowship-trained surgeons from three centres participated. Patients aged between 18 and 79 years with a primary diagnosis of glenohumeral osteoarthritis were screened for eligibility. Patients were randomized intraoperatively to either a TM or POLY glenoid component. Study intervals were: baseline, six weeks, six-, 12-, and 24 months postoperatively. The primary outcome was the Western Ontario Osteoarthritis Shoulder QOL score. Radiological images were reviewed for metal debris. Mixed effects repeated measures analysis of variance for within and between group comparisons were performed. RESULTS: A total of 93 patients were randomized (46 TM; 47 POLY). No significant or clinically important differences were found with patient-reported outcomes at 24-month follow-up. Regarding the glenoid components, there were no complications or revision surgeries in either group. Grade 1 metal debris was observed in three (6.5%) patients with TM glenoids at 24 months but outcomes were not negatively impacted. CONCLUSION: Early results from this RCT showed no differences in disease-specific QOL, radiographs, complication rates, or shoulder function between uncemented second-generation TM and cemented POLY glenoids at 24 months postoperatively. Revision surgeries and reoperations were reported in both groups, but none attributed to glenoid implant failure. At 24 months postoperatively, Grade 1 metal debris was found in 6.5% of patients with a TM glenoid but did not negatively influence patient-reported outcomes. Longer-term follow-up is needed and is underway. Cite this article: Bone Jt Open 2021;2(9):728-736.

3.
J Clin Med ; 10(24)2021 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-34945069

RESUMEN

BACKGROUND: Malpositioning of the glenoid component in total shoulder arthroplasty (TSA) remains the primary source of loosening. The purpose of this study is firstly, to quantify postoperative glenoid component position in patients having a TSA and secondly, to explore whether glenoid component radiolucency is associated with glenoid position, clinical outcomes and patient-reported measures in the short-term (two year) follow-up period. METHODS: This study was a sub-study of a larger clinical trial that included patients who underwent a TSA and who were randomized into two different glenoid types with a minimum two-year follow-up period. Post-operative radiographic assessments (six weeks and two years) were used to measure glenoid component position (version, inclination, offset) and humeral head centering anterior-posterior (AP) and superior-inferior (SI), and to assess glenoid component radiolucent scoring (modified Lazarus). Pre-operative X-rays were used to measure glenoid version, inclination and Walch classification. Patient-reported measures (PROMs) included the EQ-5D health slider and the Western Ontario Osteoarthritis (WOOS) and American Shoulder and Elbow Surgeons (ASES) score and were captured at baseline and two years postoperative. Clinical outcomes including range of motion and complications were also documented. Statistical analysis included t-tests and regression modeling. RESULTS: Ninety-one patients with an average age of 69.9 ± 6.2 years were included in this study. Glenoid component position improved significantly in version (-19.4 ± 8.6° to -17.7 ± 8.5°; p < 0.045) and inclination (11.5 ± 7.1° to 5.9 ± 6.3°; p < 0.00001) from preoperative to six weeks postoperative. Glenoid component offset in SI and humeral head centering in AP remained unchanged throughout the follow-up. Radiolucency (Lazarus classification) was recorded in 21 cases (17.3%) with a Lazarus score of 1 (15 cases) and 2 (6 cases). The EQ-5D health slider, WOOS and ASES, and ROM confirmed continuous improvements from the preoperative scores to the two-year follow-up (p < 0.05). Regression models showed no correlation between glenoid component radiolucency at two years and the postoperative week six glenoid component position; however, female gender was a significant variable. CONCLUSION: Glenoid component changes from its original native glenoid were observed following TSA. Glenoid inclination was improved more than version from baseline, and the humeral head remained well-centered in AP and SI at two years. Radiolucency of the glenoid at two years is not negatively associated with PROMs or component position; however, female gender was identified as a significant predictor and warrants further investigation. Complications are not associated with glenoid position or radiolucency, but longer-term follow-up is required.

4.
Am J Sports Med ; 34(10): 1656-61, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16832127

RESUMEN

BACKGROUND: The effect of arthroscopic rotator interval closure on glenohumeral motion and translation is not well understood, nor is the ideal location or number of sutures required for closure. HYPOTHESIS: The number of arthroscopic rotator interval closure sutures and their placement will have a significant effect on glenohumeral range of motion and anterior-posterior translation. STUDY DESIGN: Controlled laboratory study. METHODS: Using a custom testing apparatus, the authors measured range of motion in 12 fresh-frozen cadaveric shoulders; anterior-posterior translation in adduction and neutral rotation was measured in 9. Specimens were initially tested without sutures and then tested after 3 interval closures using a random sequence of (1) an isolated medial suture at the level of the glenoid, (2) an isolated lateral suture 1 cm lateral to the glenoid, or (3) both sutures followed by removal of all sutures. RESULTS: Analysis of variance demonstrated that interval closure had a significant effect on decreasing flexion (mean, 6 degrees), external rotation (mean, 10 degrees), and anterior translation (mean, 3 mm) of the adducted shoulder. There was no significant difference between the 3 interval closures in any of the tests. CONCLUSION: Arthroscopic interval closure produced significant decreases in range of motion and anterior-posterior translation. The effects of single lateral or medial suture closures were similar to the use of 2 sutures. CLINICAL RELEVANCE: This study suggests that the initial effect of arthroscopic rotator interval closure on anterior translation of the shoulder will be similar whether 1 or 2 sutures are used. In vivo studies are necessary to determine if the effect of these 2 methods would be the same over time.


Asunto(s)
Inestabilidad de la Articulación/cirugía , Manguito de los Rotadores/cirugía , Articulación del Hombro/fisiopatología , Articulación del Hombro/cirugía , Técnicas de Sutura , Adulto , Anciano , Análisis de Varianza , Artroscopía/métodos , Fenómenos Biomecánicos , Cadáver , Humanos , Persona de Mediana Edad , Rango del Movimiento Articular
5.
Instr Course Lect ; 54: 371-80, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15948466

RESUMEN

Humeral head replacement has been widely used for the treatment of complex proximal humeral fractures. The procedure is associated with a high rate of patient satisfaction as well as reliable relief of pain. The functional outcomes, however, have been variable. Reported complications include infection, neurologic injury, intraoperative fracture, instability, tuberosity malunion and nonunion, rotator cuff tear, heterotopic ossification, glenoid erosion, and stiffness. When technical factors such as tuberosity malunion or component malpositioning are considered as postoperative complications, the incidence of complications is relatively high. This high rate of complications, in turn, may be related to the wide range of reported functional outcomes.


Asunto(s)
Artroplastia de Reemplazo , Complicaciones Posoperatorias , Fracturas del Hombro/cirugía , Humanos , Complicaciones Posoperatorias/epidemiología , Prevalencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA