Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Opt Express ; 30(7): 10269-10279, 2022 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-35472998

RESUMEN

The two-way quantum clock synchronization has been shown to provide femtosecond-level synchronization capability and security against symmetric delay attacks, thus becoming a prospective method to compare and synchronize distant clocks with enhanced precision and safety. In this letter, a field test of two-way quantum synchronization between a H-maser and a Rb clock linked by a 7 km-long deployed fiber is implemented by using time-energy entangled photon-pair sources. Limited by the intrinsic frequency stability of the Rb clock, the achieved time stability at 30 s is measured as 32 ps. By applying a fiber-optic microwave frequency transfer technology to build frequency syntonization between the separated clocks, the limit set by the intrinsic frequency stability of the Rb clock is overcome. A significantly improved time stability of 1.9 ps at 30 s is achieved, which is mainly restrained by the low number of acquired photon pairs due to the low sampling rate of the utilized coincidence measurement system. Such implementation demonstrates the high practicability of the two-way quantum clock synchronization method for promoting field applications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA