RESUMEN
Characterization at the subunit level enables detailed mass spectrometric characterization of posttranslational modifications (PTMs) of monoclonal antibodies (mAbs). The implemented reduction often leaves the intramolecular disulfide bridges intact. Here, we present a capillary electrophoretic (CE) method based on a neutral-coated capillary for the separation of immunoglobulin G-degrading enzyme of Streptococcus pyogenes (IdeS) digested and reduced mAb subunits followed by mass spectrometry (MS), MS/MS identification, and trapped ion mobility mass spectrometry (timsTOF). Our CE approach enables the separation of (i) different subunit moieties, (ii) various reduction states, and (iii) positional isomers of these partly reduced subunit moieties. The location of the remaining disulfide bridges can be determined by middle-down electron transfer higher energy collisional dissociation (EThcD) experiments. All these CE-separated variants show differences in ion mobility in the timsTOF measurements. Applying the presented CE-MS/MS method, reduction parameters such as the use of chaotropic salts were studied. For the investigated antibodies, urea improved the subunit reduction significantly, whereas guanidine hydrochloride (GuHCl) leads to multiple signals of the same subunit in the CE separation. The presented CE-MS method is a powerful tool for the disulfide-variant characterization of mAbs on the subunit level. It enables understanding disulfide bridge reduction processes in antibodies and potentially other proteins.
Asunto(s)
Disulfuros , Espectrometría de Masas en Tándem , Disulfuros/química , Electroforesis Capilar/métodos , Anticuerpos Monoclonales/química , Procesamiento Proteico-PostraduccionalRESUMEN
Capillary sieving electrophoresis utilizing SDS (CE(SDS)) is one of the most applied methods for the analysis of antibody (mAb) size heterogeneity in the biopharmaceutical industry. Inadequate peak identification of observed protein fragments is still a major issue. In a recent publication, we introduced an electrophoretic 2D system, enabling online mass spectrometric detection of generic CE(SDS) separated peaks and identification of several mAb fragments. However, an improvement regarding system stability and handling of the approach was desired. Here, we introduce a novel 8-port valve in conjunction with an optimized decomplexation strategy. The valve contains four sample loops with increased distances between the separation dimensions. Thus, successively coinjection of solvent and cationic surfactant without any additional detector in the second dimension is enabled, simplifying the decomplexation strategy. Removal efficiency was optimized by testing different volumes of solvents as presample and cationic surfactant as postsample zone. 2D measurements of the light and heavy chain of the reduced NIST mAb with the 8-port valve and the optimized decomplexation strategy demonstrates the increased robustness of the system. The presented novel set-up is a step toward routine application of CE(SDS)-CZE-MS for impurity characterization of proteins in the biopharmaceutical field.
Asunto(s)
Electroforesis Capilar/métodos , Espectrometría de Masas/métodos , Nanotecnología/instrumentación , Anticuerpos Monoclonales/análisis , Anticuerpos Monoclonales/química , Electroforesis Capilar/instrumentación , Diseño de Equipo , Cadenas Pesadas de Inmunoglobulina/análisis , Cadenas Pesadas de Inmunoglobulina/química , Cadenas Ligeras de Inmunoglobulina/análisis , Cadenas Ligeras de Inmunoglobulina/química , Espectrometría de Masas/instrumentaciónRESUMEN
Hemoglobin (Hb) constitutes an important protein in clinical diagnostics-both in humans and animals. Among the high number of sequence variants, some can cause severe diseases. Moreover, chemical modifications such as glycation and carbamylation serve as important biomarkers for conditions such as diabetes and kidney diseases. In clinical routine analysis of glycated Hb, sequence variants or other Hb proteoforms can cause interference, resulting in wrong quantification results. We present a versatile and flexible capillary zone electrophoresis-mass spectrometry screening method for Hb proteoforms including sequence variants and modified species extracted from dried blood spot (DBS) samples with virtually no sample preparation. High separation power was achieved by application of a 5-layers successive multiple ionic polymer layers-coated capillary, enabling separation of positional isomers of glycated α- and ß-chains on the intact level. Quantification of glycated Hb was in good correlation with the results obtained in a clinical routine method. Identification and characterization of known and unknown proteoforms was performed by fragmentation of intact precursor ions. N-Terminal and lysine glycation could be identified on the α- and ß-chain, respectively. The versatility of the method was demonstrated by application to dog and cat DBS samples. We discovered a putative new sequence variant of the ß-chain in dog (T38 â A). The presented method enables separation, characterization, and quantification of intact proteoforms, including positional isomers of glycated species in a single run. Combined with the simple sample preparation, our method represents a valuable tool to be used for deeper characterization of clinical and veterinary samples.
Asunto(s)
Electroforesis Capilar/veterinaria , Hemoglobinas/química , Espectrometría de Masas en Tándem/veterinaria , Animales , Electroforesis Capilar/métodos , Humanos , Espectrometría de Masas en Tándem/métodosRESUMEN
Capillary electrophoresis (CE) offers fast and high-resolution separation of charged analytes from small injection volumes. Coupled to mass spectrometry (MS), it represents a powerful analytical technique providing (exact) mass information and enables molecular characterization based on fragmentation. Although hyphenation of CE and MS is not straightforward, much emphasis has been placed on enabling efficient ionization and user-friendly coupling. Though several interfaces are now commercially available, research on more efficient and robust interfacing with nano-electrospray ionization (ESI), matrix-assisted laser desorption/ionization (MALDI) and inductively coupled plasma mass spectrometry (ICP) continues with considerable results. At the same time, CE-MS has been used in many fields, predominantly for the analysis of proteins, peptides and metabolites. This review belongs to a series of regularly published articles, summarizing 248 articles covering the time between June 2016 and May 2018. Latest developments on hyphenation of CE with MS as well as instrumental developments such as two-dimensional separation systems with MS detection are mentioned. Furthermore, applications of various CE-modes including capillary zone electrophoresis (CZE), nonaqueous capillary electrophoresis (NACE), capillary gel electrophoresis (CGE) and capillary isoelectric focusing (CIEF) coupled to MS in biological, pharmaceutical and environmental research are summarized.
Asunto(s)
Electroforesis Capilar , Espectrometría de Masas , Animales , Biomarcadores/análisis , Biomarcadores/metabolismo , Electroforesis Capilar/instrumentación , Electroforesis Capilar/métodos , Humanos , Espectrometría de Masas/instrumentación , Espectrometría de Masas/métodos , Metabolómica , RatonesRESUMEN
Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) is the fundamental technique for protein separation by size. Applying this technology in capillary format, gaining high separation efficiency in a more automated way, is a key technology for size separation of proteins in the biopharmaceutical industry. However, unequivocal identification by online mass spectrometry (MS) is impossible so far, due to strong interference in the electrospray process by SDS and other components of the SDS-MW separation gel buffer. Here, a heart-cut two-dimensional electrophoretic separation system applying an electrically isolated valve with an internal loop of 20 nL is presented. The peak of interest in the CE (SDS) separation is transferred to the CZE-MS, where electrospray-interfering substances of the SDS-MW gel are separated prior to online electrospray ionization mass spectrometry. An online SDS removal strategy for decomplexing the protein-SDS complex is implemented in the second dimension, consisting of the co-injection of organic solvent and cationic surfactant. This online CE (SDS)-CZE-MS system allows MS characterization of proteoforms separated in generic CE (SDS), gaining additional separation in the CZE and detailed MS information. In general, the system can be applied to all kinds of proteins separated by CE (SDS). Here, we present results of the CE (SDS)-CZE-MS system on the analysis of several biopharmaceutically relevant antibody impurities and fragments. Additionally, the versatile application spectrum of the system is demonstrated by the analysis of extracted proteins from soybean flour. The online hyphenation of CE (SDS) resolving power and MS identification capabilities will be a powerful tool for protein and mAb characterization. Graphical abstract Two-dimensional capillary electrophoresis system hyphenated with mass spectrometry for the characterization of CE (SDS)-separated proteins. As first dimension, a generic and high MS-interfering CE (SDS) separation is performed for size separation. After heart-cut transfer of the unknown CE (SDS) protein peak, via a four-port nanoliter valve to a volatile electrolyte system as second dimension, interference-free mass spectrometric data of separated mAb fragments and soybean proteins are obtained.
Asunto(s)
Electroforesis Capilar/instrumentación , Glycine max/química , Proteínas de Soja/aislamiento & purificación , Espectrometría de Masa por Ionización de Electrospray/instrumentación , Electroforesis en Gel de Poliacrilamida , Diseño de Equipo , Dodecil Sulfato de Sodio/química , Proteínas de Soja/análisisRESUMEN
Macroecology strives to identify ecological patterns on broad spatial and temporal scales. One such pattern, Rapoport's rule, describes the tendency of species' latitudinal ranges to increase with increasing latitude. Several mechanisms have been proposed to explain this rule. Some invoke climate, either through glaciation driving differential extinction of northern species or through increased seasonal variability at higher latitudes causing higher thermal tolerances and subsequently larger ranges. Alternatively, continental tapering or higher interspecific competition at lower latitudes may be responsible. Assessing the incidence of Rapoport's rule through deep time can help to distinguish between competing explanations. Using fossil occurrence data from the Palaeobiology Database, we test these hypotheses by evaluating mammalian compliance with the rule throughout the Caenozoic of North America. Adherence to Rapoport's rule primarily coincides with periods of intense cooling and increased seasonality, suggesting that extinctions caused by changing climate may have played an important role in erecting the latitudinal gradients in range sizes seen today.
Asunto(s)
Causalidad , Ecología , Animales , MamíferosRESUMEN
Size heterogeneity analysis by capillary sieving electrophoresis utilizing sodium dodecyl sulfate (CE(SDS)) with optical detection is a major method applied for release and stability testing of monoclonal antibodies (mAbs) in biopharmaceutical applications. Identification of mAb-fragments and impurities observed with CE(SDS) is of outstanding importance for the assessment of critical quality attributes and development of the analytical control system. Mass spectrometric (MS) detection is a powerful tool for protein identification and characterization. Unfortunately, CE(SDS) is incompatible with online MS-hyphenation due to strong ionization suppression of SDS and other separation buffer components. Here, we present a comprehensive platform for full characterization of individual CE(SDS)-separated peaks by CE(SDS)-capillary zone electrophoresis-top-down-MS. The peak of interest is transferred from the first to the second dimension via an 8-port valve to remove MS-incompatible components. Full characterization of mAb byproducts is performed by intact mass determination and fragmentation by electron transfer dissociation, higher-energy collisional dissociation, and ultraviolet photodissociation. This enables online determination of intact mass as well as sequence verification of individual CE(SDS)-separated peaks simultaneously. A more substantiated characterization of unknown CE(SDS) peaks by exact localization of modifications without prior digestion is facilitated. High sensitivity is demonstrated by successful mass and sequence verification of low abundant, unknown CE(SDS) peaks from two stressed mAb samples. Good fragmentation coverages are obtained by MS2, enabling unequivocal identification of these mAb-fragments. Also, the differentiation of reduced/non-reduced intra-protein disulfide bonds is demonstrated. In summary, a reliable and unambiguous online MS2 identification of unknown compounds of low-abundant individual CE(SDS) peaks is enabled.
Asunto(s)
Anticuerpos Monoclonales , Electroforesis Capilar , Fragmentos de Inmunoglobulinas , Espectrometría de Masas , Dodecil Sulfato de SodioRESUMEN
The analysis of product-related substances and impurities is a critical step in the biopharmaceutical quality control of multiattribute monoclonal antibodies (mAbs), as posttranslational modifications or other variants can influence the product's biological activity. Many approaches are available for variant analysis; however, they are either variant-specific, mAb-specific, time-consuming, or require expensive equipment. Here, we present a generic capillary electrophoretic method based on a neutral-coated capillary which was coupled to mass spectrometry (MS) via the nanoCEasy interface for mAb variant analysis at the subunit level (enzymatically digested and reduced mAb). The method enabled the separation of several (i) size variants (e.g. glycosylation variants) and (ii) charge variants (e.g. c-terminal lysin clipping) as well as (iii) multiple other proteoforms (e.g. additional glycation) and (iv) incompletely reduced subunits. Separated variants were confirmed by MS/MS fragmentation even for small mass deviations like deamidation or open disulfide bridges. The system, initially developed for one mAb, was tested with nine other IgG1s to show the general applicability of the system. The presented multiattribute method enables fast and detailed characterization of mAb variants with little sample preparation and relatively simple separation equipment enabling the separation of a large set of mAb variants.
Asunto(s)
Anticuerpos Monoclonales , Electroforesis Capilar , Espectrometría de Masas en Tándem , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/análisis , Electroforesis Capilar/métodos , Espectrometría de Masas en Tándem/métodos , Glicosilación , Procesamiento Proteico-Postraduccional , Inmunoglobulina G/química , Inmunoglobulina G/análisis , Espectrometría de Masas/métodos , Subunidades de Proteína/químicaRESUMEN
The objective of this study was to characterize the ABL1-BCR fusion gene in 76 BCR-ABL1-positive chronic myeloid leukemia (CML) patients regarding expression as well as genomic status, to assess the frequency of ABL1-BCR gene deletion in these patients, which has been reported to be an adverse prognostic factor in Philadelphia chromosome-positive CML. Patients were analyzed for ABL1-BCR 1b-b3 and/or 1b-b4 transcription by RT-PCR analysis. ABL1-BCR gene status was analyzed by FISH in 16 CML patients with no ABL1-BCR transcript. FISH revealed a partial or total deletion of the ABL1-BCR gene in 9/16 and localized the 5' portion of ABL1 and the 3' portion of BCR at separated loci in 5/16 patients. The latter FISH pattern resulted from a nonreciprocal translocation in two and a complex translocation in three individuals. In 2/16 patients, FISH could not exclude an intact ABL1-BCR fusion gene. Thus, most CML patients without ABL1-BCR transcript could be characterized cytogenetically to belong to two major subgroups: a silent ABL1-BCR gene was attributed to a deletion in der(9)t(9;22) in 56% of the investigated patients or to variants of a standard t(9;22) (approximately 31%). Conversely, none of the 50 patients with an ABL1-BCR transcript exhibited a variant t(9;22) in GTG-banding analysis. Thus, genomic aberrations such as deletions or complex genomic rearrangements are the basic and most frequent cause for ABL1-BCR RNA negativity in CML. The heterogeneity of the underlying molecular mechanisms may explain divergent clinical implications described for patients with an ABL1-BCR deletion and those with no ABL1-BCR transcript.