Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Radiol Prot ; 40(3): 877-891, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32604085

RESUMEN

OBJECTIVES: The detection of Coronavirus Disease 2019 (COVID-19) by reverse transcription polymerase chain reaction (RT-PCR) has varying sensitivity. Computed tomography (CT) of the chest can verify infection in patients with clinical symptoms and a negative test result, accelerating treatment and actions to prevent further contagion. However, CT employs ionising radiation. The purpose of this study was to evaluate protocol settings, associated radiation exposure, image quality and diagnostic performance of a low-dose CT protocol in a university hospital setting. MATERIALS AND METHODS: Chest CT examinations were performed on a single scanner (Somatom Definition Edge, Siemens Healthineers, Germany) in 105 symptomatic patients (60 male, 45 female). Images were evaluated with regard to protocol parameters, image quality, radiation exposure and diagnostic accuracy. Serial RT-PCR served as the standard of reference. Based on this reference standard sensitivity, specificity, positive and negative predictive values of CT with 95% confidence interval were calculated. RESULTS: The mean effective dose was 1.3 ± 0.4 mSv (0.7-2.9 mSv) for the patient cohort (mean age 66.6 ± 16.7 years (19-94 years), mean body mass index (BMI) 26.6 ± 5.3 kg m-2 (16-46 kg/m2)). A sensitivity of 100 [95% CI: 82-100]%, a specificity of 78 [95% CI: 68-86]%, a positive predictive value of 50 [95% CI: 33-67]% and a negative predictive value of 100 [95% CI: 95-100]% were obtained. No COVID-19 diagnoses were missed by CT. Image noise did not strongly correlate with BMI or patient diameter and was rated as average. CONCLUSIONS: We presented a robust imaging procedure with a chest CT protocol for confident diagnosis of COVID-19. Even for an overweight patient cohort, an associated radiation exposure of only 1.3 ± 0.4 mSv was achieved with sufficient diagnostic quality to exclude COVID-19.


Asunto(s)
Infecciones por Coronavirus/diagnóstico por imagen , Neumonía Viral/diagnóstico por imagen , Dosis de Radiación , Radiografía Torácica/normas , Tomografía Computarizada por Rayos X/normas , Adulto , Anciano , Anciano de 80 o más Años , Betacoronavirus , COVID-19 , Femenino , Hospitales Universitarios , Humanos , Masculino , Persona de Mediana Edad , Pandemias , Valor Predictivo de las Pruebas , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , SARS-CoV-2 , Sensibilidad y Especificidad
2.
Radiology ; 285(1): 223-230, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28640695

RESUMEN

Purpose To determine whether signal intensity (SI) in T1 sequences as a potential indicator of gadolinium deposition increases after repeated administration of the macrocyclic gadolinium-based contrast agents (GBCAs) gadoteridol and gadoterate meglumine in a pediatric cohort. Materials and Methods This retrospective case-control study of children with brain tumors who underwent nine or more contrast material-enhanced brain magnetic resonance (MR) imaging studies from 2008 to 2015 was approved by the local ethics board. Informed consent was obtained for MR imaging. Twenty-four case patients aged 5-18 years and appropriate control patients with nonpathologic MR neuroimaging findings (and no GBCA administration), matched for age and sex, were inculded. SI was measured on unenhanced T1-weighted MR images for the following five regions of interest (ROIs): the dentate nucleus (DN), pons, substantia nigra (SN), pulvinar thalami, and globus pallidus (GP). Paired t tests were used to compare SI and SI ratios (DN to pons, GP to thalamus) between case patients and control patients. Pearson correlations between relative signal changes and the number of GBCA administrations and total GBCA dose were calculated. Results The mean number of GBCA administrations was 14.2. No significant differences in mean SI for any ROI and no group differences were found when DN-to-pons and GP-to-pulvinar ratios were compared (DN-to-pons ratio in case patients: mean, 1.0083 ± 0.0373 [standard deviation]; DN-to-pons ratio in control patients: mean, 1.0183 ± 0.01917; P = .37; GP-to-pulvinar ratio in case patients: mean, 1.1335 ± 0.04528; and GP-to-pulvinar ratio in control patients: mean, 1.1141 ± 0.07058; P = .29). No correlation was found between the number of GBCA administrations or the total amount of GBCA administered and signal change for any ROI. (Number of GBCA applications: DN: r = -0.254, P = .31; pons: r = -0.097, P = .65; SN: r = -0.194, P = .38; GP: r = -0.175, P = .41; pulvinar: r = -0.067, P = .75; total amount of administered GBCA: DN: r = 0.091, P = .72; pons: r = 0.106, P = .62; SN: r = -0.165, P = .45; GP: r = 0.111, P = .61; pulvinar: r = 0.173, P = .42.) Conclusion Multiple intravenous administrations of these macrocyclic GBCAs in children were not associated with a measurable increase in SI in T1 sequences as an indicator of brain gadolinium deposition detectable by using MR imaging. Additional imaging and pathologic studies are needed to confirm these findings. © RSNA, 2017 Online supplemental material is available for this article.


Asunto(s)
Encéfalo/efectos de los fármacos , Encéfalo/diagnóstico por imagen , Medios de Contraste , Gadolinio , Imagen por Resonancia Magnética , Administración Intravenosa , Adolescente , Encéfalo/metabolismo , Encéfalo/patología , Estudios de Casos y Controles , Niño , Preescolar , Medios de Contraste/administración & dosificación , Medios de Contraste/metabolismo , Medios de Contraste/farmacología , Medios de Contraste/uso terapéutico , Femenino , Gadolinio/administración & dosificación , Gadolinio/metabolismo , Gadolinio/farmacología , Gadolinio/uso terapéutico , Humanos , Masculino , Meglumina/administración & dosificación , Meglumina/metabolismo , Meglumina/farmacología , Meglumina/uso terapéutico , Compuestos Organometálicos/administración & dosificación , Compuestos Organometálicos/metabolismo , Compuestos Organometálicos/farmacología , Compuestos Organometálicos/uso terapéutico , Estudios Retrospectivos
3.
Rofo ; 194(10): 1110-1118, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35545100

RESUMEN

PURPOSE: To assess whether it is possible to reliably detect patients with strong suspicion of COVID-19 despite initially negative quantitative polymerase-chain-reaction (qPCR) tests by means of computed tomography (CT). MATERIALS AND METHODS: 437 patients with suspected COVID-19 but initially negative qPCR and subsequent chest CT between March 13 and November 30, 2020 were included in this retrospective study. CT findings were compared to results of successive qPCR tests (minimum of 3 qPCR tests if CT suggested infection) to determine the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT for diagnosing COVID-19. RESULTS: COVID-19 was diagnosed correctly with a sensitivity of 100 % [95 % confidence interval (CI): 65-100] and a specificity of 88 % [95 % CI: 84-90]. A PPV of 12 % [95 % CI: 6-22] and an NPV of 100 % [95 % CI: 99-100] were determined. CONCLUSION: CT is able to detect COVID-19 before qPCR in initially negative patients in this special study setting. Similar CT findings in COVID-19 and other atypical pneumonias can lead to high numbers of false-positive patients, reducing the specificity of CT. KEY POINTS: · Low-dose chest CT is able to diagnose COVID-19 in symptomatic patients even in cases of an initially negative quantitative PCR result and therefore is a fast support method to detect COVID-19, especially in early disease.. · Low-dose chest CT can reliably exclude COVID-19 in a pandemic setting.. · CT does not always ensure a reliable differentiation from other viral diseases.. CITATION FORMAT: · Valentin B, Steuwe A, Wienemann T, et al. CT Findings in Patients with COVID-19-Compatible Symptoms but Initially Negative qPCR Test. Fortschr Röntgenstr 2022; 194: 1110 - 1118.


Asunto(s)
COVID-19 , COVID-19/diagnóstico por imagen , Humanos , Estudios Retrospectivos , SARS-CoV-2 , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
4.
Rofo ; 194(8): 862-872, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35211925

RESUMEN

PURPOSE: Classifications were created to facilitate radiological evaluation of the novel coronavirus disease 2019 (COVID-19) on computed tomography (CT) images. The categorical CT assessment scheme (CO-RADS) categorizes lung parenchymal changes according to their likelihood of being caused by SARS-CoV-2 infection. This study investigates the diagnostic accuracy of diagnosing COVID-19 with CO-RADS compared to the Thoracic Imaging Section of the German Radiological Society (DRG) classification and Radiological Society of North America (RSNA) classification in an anonymized patient cohort. To mimic advanced disease stages, follow-up examinations were included as well. METHOD: This study includes all patients undergoing chest CT in the case of a suspected SARS-CoV-2 infection or an already confirmed infection between March 13 and November 30, 2020. During the study period, two regional lockdowns occurred due to high incidence values, increasing the pre-test probability of COVID-19. Anonymized CT images were reviewed retrospectively and in consensus by two radiologists applying CO-RADS, DRG, and RSNA classification. Afterwards, CT findings were compared to results of sequential real-time reverse transcriptase polymerase chain reaction (qPCR) test performed during hospitalization to determine statistical analysis for diagnosing COVID-19. RESULTS: 536 CT examinations were included. CO-RADS, DRG and RSNA achieved an NPV of 96 %/94 %/95 % (CO-RADS/DRG/RSNA), PPV of 83 %/80 %/88 %, sensitivity of 86 %/76 %/80 %, and specificity of 96 %/95 %/97 %. The disease prevalence was 20 %. CONCLUSION: All applied classifications can reliably exclude a SARS-CoV-2 infection even in an anonymous setting. Nevertheless, pre-test probability was high in our study setting and has a great influence on the classifications. Therefore, the applicability of the individual classifications will become apparent in the future with lower prevalence and incidence of COVID-19. KEY POINTS: · CO-RADS, DRG, and RSNA classifications help to reliably detect infected patients in an anonymized setting. · Pre-test probability has a great influence on the individual classifications. · Difficulties in an anonymized study setting are severe pulmonary changes and residuals.. CITATION FORMAT: · Valentin B, Steuwe A, Wienemann T et al. Applicability of CO-RADS in an Anonymized Cohort Including Early and Advanced Stages of COVID-19 in Comparison to the Recommendations of the German Radiological Society and Radiological Society of North America. Fortschr Röntgenstr 2022; 194: 862 - 872.


Asunto(s)
COVID-19 , COVID-19/diagnóstico por imagen , Control de Enfermedades Transmisibles , Humanos , América del Norte/epidemiología , Estudios Retrospectivos , SARS-CoV-2
5.
Br J Radiol ; 94(1117): 20200677, 2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-33095654

RESUMEN

OBJECTIVES: Modern reconstruction and post-processing software aims at reducing image noise in CT images, potentially allowing for a reduction of the employed radiation exposure. This study aimed at assessing the influence of a novel deep-learning based software on the subjective and objective image quality compared to two traditional methods [filtered back-projection (FBP), iterative reconstruction (IR)]. METHODS: In this institutional review board-approved retrospective study, abdominal low-dose CT images of 27 patients (mean age 38 ± 12 years, volumetric CT dose index 2.9 ± 1.8 mGy) were reconstructed with IR, FBP and, furthermore, post-processed using a novel software. For the three reconstructions, qualitative and quantitative image quality was evaluated by means of CT numbers, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in six different ROIs. Additionally, the reconstructions were compared using SNR, peak SNR, root mean square error and mean absolute error to assess structural differences. RESULTS: On average, CT numbers varied within 1 Hounsfield unit (HU) for the three assessed methods in the assessed ROIs. In soft tissue, image noise was up to 42% lower compared to FBP and up to 27% lower to IR when applying the novel software. Consequently, SNR and CNR were highest with the novel software. For both IR and the novel software, subjective image quality was equal but higher than the image quality of FBP-images. CONCLUSION: The assessed software reduces image noise while maintaining image information, even in comparison to IR, allowing for a potential dose reduction of approximately 20% in abdominal CT imaging. ADVANCES IN KNOWLEDGE: The assessed software reduces image noise by up to 27% compared to IR and 48% compared to FBP while maintaining the image information.The reduced image noise allows for a potential dose reduction of approximately 20% in abdominal imaging.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Dosis de Radiación , Radiografía Abdominal/métodos , Tomografía Computarizada por Rayos X/métodos , Abdomen/diagnóstico por imagen , Adulto , Aprendizaje Profundo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Relación Señal-Ruido , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA