Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Cardiovasc Revasc Med ; 63: 1-7, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38423848

RESUMEN

PURPOSE: To evaluate the safety and effectiveness of the novel, next-generation Myval Octacor - Transcatheter Heart Valve (THV) in patients with severe, symptomatic, native aortic stenosis (AS). METHODS: This multicenter, real-world observational registry included 123 patients with severe symptomatic AS, across 16 Indian centers who underwent treatment with the novel Myval Octacor THV. Study endpoints included all-cause mortality, all stroke, acute kidney injury (AKI), major vascular complications, moderate or severe paravalvular leakage (PVL) and new permanent pacemaker implantation (PPI) until 30 days follow-up. RESULTS: Of the 123 patients (average age 70.07 ± 8.33 years), 37.4 % (n = 46) were female and 39.84 % presented with bicuspid valves. The technical success rate of the procedure was 100 % and the device success rate at 30 days was 98.4 %. At 30 days (n = 123) after the procedure, the overall mortality was 1.6 %. AKI occurred in 1.6 % of patients and there was no incidence of stroke, bleeding (types 3 and 4), and major vascular complications. In an analysis of 31 patients whose echocardiographic parameters were available across all timepoints, there were significant improvements in the mean pressure gradient (54.31 ± 18.19 mmHg vs. 10.42 ± 4.24 mmHg; p < 0.0001) and effective orifice area (0.66 ± 0.21 cm2 vs. 1.80 ± 0.44 cm2; p < 0.0001) from baseline to the 30-day follow-up. None of the patients experienced severe PVL, while moderate PVL was observed in two patients (1.6 %). CONCLUSIONS: Early outcomes of the next-generation, novel Myval Octacor THV proved its safety and effectiveness in the treatment of severe AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Anciano , India , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Factores de Tiempo , Anciano de 80 o más Años , Persona de Mediana Edad , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Factores de Riesgo , Recuperación de la Función , Complicaciones Posoperatorias , Estudios Retrospectivos , Hemodinámica
2.
Ann Card Anaesth ; 26(1): 78-82, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36722592

RESUMEN

Concomitant mitral and aortic valve stenosis in a patient with mitral annular calcification and porcelain aorta poses a unique problem to the surgical team. Transcatheter aortic and mitral valve replacements in native valves offer a viable option for such selected group of patients. We present the case of a 54-year-old male who presented with severe aortic stenosis (AS) and severe mitral stenosis (MS) but was deemed high risk for surgery owing to intense calcification of the aorta and mitral annular calcification, and successfully underwent transcatheter double native valve replacement.


Asunto(s)
Estenosis de la Válvula Aórtica , Calcinosis , Procedimientos Quirúrgicos Cardíacos , Estenosis de la Válvula Mitral , Masculino , Humanos , Persona de Mediana Edad , Estenosis de la Válvula Mitral/complicaciones , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Calcinosis/complicaciones , Calcinosis/diagnóstico por imagen , Calcinosis/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía
3.
Future Cardiol ; 17(1): 73-80, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32628046

RESUMEN

The transcatheter aortic valve replacement (TAVR) is an established treatment for patients with severe symptomatic aortic stenosis (AS) at prohibitive risk for surgery. It is an alternative treatment to surgical aortic valve replacement in patients with AS at intermediate- and high-surgical risk. Although regulatory authorities extend the indications of TAVR to treat patients at low-surgical risk, the limitations of earlier-generation transcatheter heart valve (THV) systems accelerate the development of improved newer generation of THV systems. Myval™ THV (Meril Life Sciences Pvt. Ltd., Vapi, Gujarat, India) is a newer-generation, balloon-expandable TAVR system with features that facilitate accurate positioning of the bioprosthetic valve and favorable procedural and clinical outcomes. This review summarizes existing preclinical and clinical data on Myval THV for the intervention of symptomatic native AS and lays out the plan for future research program.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Resultado del Tratamiento
4.
Indian Heart J ; 69(3): 382-392, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28648438

RESUMEN

Dyslipidemia is the most important atherosclerotic risk factor. Review of population based studies in India shows increasing mean total cholesterol levels. Recent studies have reported that high cholesterol is present in 25-30% of urban and 15-20% rural subjects. This prevalence is lower than high-income countries. The most common dyslipidemia in India are borderline high LDL cholesterol, low HDL cholesterol and high triglycerides. Studies have reported that over a 20-year period total cholesterol, LDL cholesterol and triglyceride levels have increased among urban populations. Case-control studies have reported that there is significant association of coronary events with raised apolipoproteinB, total cholesterol, LDL cholesterol and non-HDL cholesterol and inverse association with high apolipoproteinA and HDL cholesterol. Prevalence of suspected familial hypercholesterolemia in urban subjects varies from 1:125 to 1:450. Only limited studies exist regarding lipid abnormalities in children. There is low awareness, treatment and control of hypercholesterolemia in India.


Asunto(s)
Dislipidemias/epidemiología , Lípidos/sangre , Dislipidemias/sangre , Humanos , India/epidemiología , Morbilidad/tendencias
5.
Ann Thorac Surg ; 103(5): 1399-1405, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-27765175

RESUMEN

BACKGROUND: Smaller transcatheter aortic valve replacement (TAVR) delivery systems have increased the number of patients eligible for transfemoral procedures while decreasing the need for transaortic (TAo) or transapical (TA) access. As a result, newer TAVR centers are likely to have less exposure to these alternative access techniques, making it harder to achieve proficiency. The purpose of this study was to evaluate the learning curve for TAVR approaches and compare perioperative outcomes. METHODS: From January 2008 to December 2014, 400 patients underwent TAVR (transfemoral, n = 179; TA, n = 120; and TAo, n = 101)). Learning curves were constructed using metrics of contrast utilization, procedural, and fluoroscopy times. Outcomes during the learning curve were compared with after proficiency was achieved. RESULTS: Depending on the metric, learning curves for all three routes differed slightly but all demonstrated proficiency by the 50th case. There were no significant differences in procedural times whereas improvements in contrast use were most notable for TA (69 ± 40 mL versus 50 ± 23 mL, p = 0.002). For both TA and TAo, fewer patients received transfusions once proficiency was reached (62% versus 34%, p = 0.003, and 42% versus 14%, p = 0.002, respectively). No differences in 30-day or 1-year mortality were seen before or after proficiency was reached for any approach. CONCLUSIONS: The learning curves for TA and TAo are distinct but technical proficiency begins to develop by 25 cases and becomes complete by 50 cases for both approaches. Given the relatively low volume of alternative access, achieving technical proficiency may take significant time. However, technical proficiency had no effect on 30-day or 1-year mortality for any access approach.


Asunto(s)
Instituciones Cardiológicas , Curva de Aprendizaje , Reemplazo de la Válvula Aórtica Transcatéter/educación , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Competencia Clínica , Medios de Contraste/administración & dosificación , Femenino , Necesidades y Demandas de Servicios de Salud , Humanos , Comunicación Interdisciplinaria , Colaboración Intersectorial , Estimación de Kaplan-Meier , Masculino , Tempo Operativo , Selección de Paciente , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA