Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
2.
Nature ; 584(7820): 304-309, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32581365

RESUMEN

The human GABAB receptor-a member of the class C family of G-protein-coupled receptors (GPCRs)-mediates inhibitory neurotransmission and has been implicated in epilepsy, pain and addiction1. A unique GPCR that is known to require heterodimerization for function2-6, the GABAB receptor has two subunits, GABAB1 and GABAB2, that are structurally homologous but perform distinct and complementary functions. GABAB1 recognizes orthosteric ligands7,8, while GABAB2 couples with G proteins9-14. Each subunit is characterized by an extracellular Venus flytrap (VFT) module, a descending peptide linker, a seven-helix transmembrane domain and a cytoplasmic tail15. Although the VFT heterodimer structure has been resolved16, the structure of the full-length receptor and its transmembrane signalling mechanism remain unknown. Here we present a near full-length structure of the GABAB receptor, captured in an inactive state by cryo-electron microscopy. Our structure reveals several ligands that preassociate with the receptor, including two large endogenous phospholipids that are embedded within the transmembrane domains to maintain receptor integrity and modulate receptor function. We also identify a previously unknown heterodimer interface between transmembrane helices 3 and 5 of both subunits, which serves as a signature of the inactive conformation. A unique 'intersubunit latch' within this transmembrane interface maintains the inactive state, and its disruption leads to constitutive receptor activity.


Asunto(s)
Microscopía por Crioelectrón , Receptores de GABA-B/química , Receptores de GABA-B/ultraestructura , Calcio/metabolismo , Etanolaminas/química , Etanolaminas/metabolismo , Humanos , Ligandos , Modelos Moleculares , Fosforilcolina/química , Fosforilcolina/metabolismo , Dominios Proteicos , Multimerización de Proteína , Subunidades de Proteína/química , Subunidades de Proteína/metabolismo , Receptores de GABA-B/metabolismo , Relación Estructura-Actividad
3.
Radiographics ; 44(2): e230129, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38300813

RESUMEN

The breasts undergo marked physiologic changes during lactation that can make conventional imaging evaluation with mammography and US challenging. MRI can be a valuable diagnostic aid to differentiate physiologic and benign processes from malignancy in patients who are lactating. In addition, MRI may allow more accurate delineation of disease involvement than does conventional imaging and assists in locoregional staging, screening of the contralateral breast, assessment of response to neoadjuvant chemotherapy, and surgical planning. Although the American College of Radiology recommends against patients undergoing contrast-enhanced MRI during pregnancy because of fetal safety concerns, contrast-enhanced MRI is safe during lactation. As more women delay childbearing, the incidence of pregnancy-associated breast cancer (PABC) and breast cancer in lactating women beyond the 1st year after pregnancy is increasing. Thus, MRI is increasingly being performed in lactating women for diagnostic evaluation and screening of patients at high risk. PABC is associated with a worse prognosis than that of non-PABCs, with delays in diagnosis contributing to an increased likelihood of advanced-stage disease at diagnosis. Familiarity with the MRI features of the lactating breast and the appearance of various pathologic conditions is essential to avoid diagnostic pitfalls and prevent delays in cancer diagnosis and treatment. The authors review clinical indications for breast MRI during lactation, describe characteristic features of the lactating breast at MRI, and compare MRI features of a spectrum of benign and malignant breast abnormalities. ©RSNA, 2024 Test Your Knowledge questions for this article are available in the supplemental material. See the invited commentary by Chikarmane in this issue.


Asunto(s)
Azidas , Neoplasias de la Mama , Lactancia , Propanolaminas , Embarazo , Femenino , Humanos , Mama/diagnóstico por imagen , Mama/patología , Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Imagen por Resonancia Magnética/métodos
4.
Proc Natl Acad Sci U S A ; 118(51)2021 12 21.
Artículo en Inglés | MEDLINE | ID: mdl-34916296

RESUMEN

The human extracellular calcium-sensing (CaS) receptor controls plasma Ca2+ levels and contributes to nutrient-dependent maintenance and metabolism of diverse organs. Allosteric modulation of the CaS receptor corrects disorders of calcium homeostasis. Here, we report the cryogenic-electron microscopy reconstructions of a near-full-length CaS receptor in the absence and presence of allosteric modulators. Activation of the homodimeric CaS receptor requires a break in the transmembrane 6 (TM6) helix of each subunit, which facilitates the formation of a TM6-mediated homodimer interface and expansion of homodimer interactions. This transformation in TM6 occurs without a positive allosteric modulator. Two modulators with opposite functional roles bind to overlapping sites within the transmembrane domain through common interactions, acting to stabilize distinct rotamer conformations of key residues on the TM6 helix. The positive modulator reinforces TM6 distortion and maximizes subunit contact to enhance receptor activity, while the negative modulator strengthens an intact TM6 to dampen receptor function. In both active and inactive states, the receptor displays symmetrical transmembrane conformations that are consistent with its homodimeric assembly.


Asunto(s)
Calcio/metabolismo , Regulación de la Expresión Génica/fisiología , Homeostasis/fisiología , Receptores Sensibles al Calcio/metabolismo , Microscopía por Crioelectrón , Células HEK293 , Humanos , Modelos Moleculares , Conformación Proteica , Dominios Proteicos , Receptores Sensibles al Calcio/genética , Transducción de Señal
5.
Radiology ; 306(3): e213199, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36378030

RESUMEN

Background There is increasing interest in noncontrast breast MRI alternatives for tumor visualization to increase the accessibility of breast MRI. Purpose To evaluate the feasibility and accuracy of generating simulated contrast-enhanced T1-weighted breast MRI scans from precontrast MRI sequences in biopsy-proven invasive breast cancer with use of deep learning. Materials and Methods Women with invasive breast cancer and a contrast-enhanced breast MRI examination that was performed for initial evaluation of the extent of disease between January 2015 and December 2019 at a single academic institution were retrospectively identified. A three-dimensional, fully convolutional deep neural network simulated contrast-enhanced T1-weighted breast MRI scans from five precontrast sequences (T1-weighted non-fat-suppressed [FS], T1-weighted FS, T2-weighted FS, apparent diffusion coefficient, and diffusion-weighted imaging). For qualitative assessment, four breast radiologists (with 3-15 years of experience) blinded to whether the method of contrast was real or simulated assessed image quality (excellent, acceptable, good, poor, or unacceptable), presence of tumor enhancement, and maximum index mass size by using 22 pairs of real and simulated contrast-enhanced MRI scans. Quantitative comparison was performed using whole-breast similarity and error metrics and Dice coefficient analysis of enhancing tumor overlap. Results Ninety-six MRI examinations in 96 women (mean age, 52 years ± 12 [SD]) were evaluated. The readers assessed all simulated MRI scans as having the appearance of a real MRI scan with tumor enhancement. Index mass sizes on real and simulated MRI scans demonstrated good to excellent agreement (intraclass correlation coefficient, 0.73-0.86; P < .001) without significant differences (mean differences, -0.8 to 0.8 mm; P = .36-.80). Almost all simulated MRI scans (84 of 88 [95%]) were considered of diagnostic quality (ratings of excellent, acceptable, or good). Quantitative analysis demonstrated strong similarity (structural similarity index, 0.88 ± 0.05), low voxel-wise error (symmetric mean absolute percent error, 3.26%), and Dice coefficient of enhancing tumor overlap of 0.75 ± 0.25. Conclusion It is feasible to generate simulated contrast-enhanced breast MRI scans with use of deep learning. Simulated and real contrast-enhanced MRI scans demonstrated comparable tumor sizes, areas of tumor enhancement, and image quality without significant qualitative or quantitative differences. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Slanetz in this issue. An earlier incorrect version appeared online. This article was corrected on January 17, 2023.


Asunto(s)
Neoplasias de la Mama , Aprendizaje Profundo , Femenino , Humanos , Persona de Mediana Edad , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Estudios Retrospectivos , Mama/diagnóstico por imagen , Mama/patología , Imagen por Resonancia Magnética/métodos , Medios de Contraste
6.
Radiology ; 297(2): 316-324, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32870133

RESUMEN

Background Women are increasingly delaying childbearing, and thus lactation, into their 30s and 40s, when mammography would typically be the initial imaging modality to evaluate palpable masses in the general population. Current guidelines recommend US as the first-line imaging modality for palpable masses in pregnant and lactating women, but data regarding breastfeeding women age 30 years and older are near nonexistent. Purpose To evaluate the diagnostic performance of targeted US as the primary imaging modality for the evaluation of palpable masses in lactating women, including those of advanced maternal age. Materials and Methods Lactating women with palpable breast masses evaluated at targeted US over a 17-year period (January 2000 to July 2017) were retrospectively identified. All US evaluations were performed at diagnostic evaluation, and mammography was performed at the discretion of the interpreting radiologist. Breast Imaging Reporting and Data System assessments, imaging, and pathology results were collected. Descriptive statistics and 2 × 2 contingency tables were assessed at the patient level. Results There were 167 women (mean age, 35 years ± 5 [standard deviation]), 101 of whom (60%) were of advanced maternal age (≥35 years). All women underwent targeted US, and 98 (59%) underwent mammography in addition to US. The frequency of malignancy was five of 167 (3.0%). Targeted US demonstrated a sensitivity and specificity of five of five (100%; 95% confidence interval [CI]: 48%, 100%) and 114 of 162 (70%; 95% CI: 63%, 77%), respectively. Negative predictive value, positive predictive value of an abnormal examination, and positive predictive value of biopsy were 114 of 114 (100%; 95% CI: 97%, 100%), five of 53 (9.4%; 95% CI: 3%, 21%), and five of 50 (10%; 95% CI: 3%, 22%), respectively. In the subset of 98 women who underwent mammography in addition to US, mammography depicted seven incidental suspicious findings, which lowered the specificity from 62 of 93 (67%; 95% CI: 56%, 76%) to 57 of 93 (61%; 95% CI: 51%, 71%) (P = .02). Conclusion Targeted US depicted all malignancies in lactating women with palpable masses. Adding mammography increased false-positive findings without any additional cancer diagnoses. © RSNA, 2020 See also the editorial by Newell in this issue.


Asunto(s)
Lactancia Materna , Neoplasias de la Mama/diagnóstico por imagen , Edad Materna , Ultrasonografía Mamaria , Adulto , Biopsia , Femenino , Humanos , Hallazgos Incidentales , Mamografía , Palpación , Valor Predictivo de las Pruebas , Estudios Retrospectivos
7.
Radiology ; 286(1): 60-70, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28885890

RESUMEN

Purpose To evaluate the association between Breast Imaging Reporting and Data System (BI-RADS) mammographic and magnetic resonance (MR) imaging features and breast cancer recurrence risk in patients with estrogen receptor-positive breast cancer who underwent the Oncotype DX assay. Materials and Methods In this institutional review board-approved and HIPAA-compliant protocol, 408 patients diagnosed with invasive breast cancer between 2004 and 2013 who underwent the Oncotype DX assay were identified. Mammographic and MR imaging features were retrospectively collected according to the BI-RADS lexicon. Linear regression assessed the association between imaging features and Oncotype DX test recurrence score (ODxRS), and post hoc pairwise comparisons assessed ODxRS means by using imaging features. Results Mammographic breast density was inversely associated with ODxRS (P ≤ .05). Average ODxRS for density category A was 24.4 and that for density category D was 16.5 (P < .02). Both indistinct mass margins and fine linear branching calcifications at mammography were significantly associated with higher ODxRS (P < .01 and P < .03, respectively). Masses with indistinct margins had an average ODxRS of 31.3, which significantly differed from the ODxRS of 18.5 for all other mass margins (P < .01). The average ODxRS for fine linear branching calcifications was 29.6, whereas the ODxRS for all other suspicious calcification morphologies was 19.4 (P < .03). Average ODxRS was significantly higher for irregular mass margins at MR imaging compared with spiculated mass margins (24.0 vs 17.6; P < .02). The presence of nonmass enhancement at MR imaging was associated with lower ODxRS than was its absence (16.4 vs 19.9; P < .05). Conclusion The BI-RADS features of mammographic breast density, calcification morphology, mass margins at mammography and MR imaging, and nonmass enhancement at MR imaging have the potential to serve as imaging biomarkers of breast cancer recurrence risk. Further prospective studies involving larger patient cohorts are needed to validate these preliminary findings. © RSNA, 2017 Online supplemental material is available for this article.


Asunto(s)
Neoplasias de la Mama , Genómica/métodos , Imagen por Resonancia Magnética/métodos , Mamografía/métodos , Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/genética , Neoplasias de la Mama/patología , Neoplasias de la Mama/radioterapia , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Persona de Mediana Edad
9.
Radiology ; 289(3): 630-638, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30277445

RESUMEN

Purpose To compare the performance of two-dimensional synthetic mammography (SM) plus digital breast tomosynthesis (DBT) versus conventional full-field digital mammography (FFDM) in the detection of microcalcifications on screening mammograms. Materials and Methods In this retrospective multireader observer study, 72 consecutive screening mammograms recalled for microcalcifications from June 2015 through August 2016 were evaluated with both FFDM and DBT. The data set included 54 mammograms with benign microcalcifications and 18 mammograms with malignant microcalcifications, and 20 additional screening mammograms without microcalcifications used as controls. FFDM alone was compared to synthetic mammography plus DBT. Four readers independently reviewed each data set and microcalcification recalls were tabulated. Sensitivity and specificity for microcalcification detection were calculated for SM plus DBT and for FFDM alone. Interreader agreement was calculated with Fleiss kappa values. Results Reader agreement was kappa value of 0.66 (P < .001) for FFDM and 0.63 (P < .001) for SM plus DBT. For FFDM, the combined reader sensitivity for all microcalcifications was 80% (229 of 288; 95% confidence interval [CI]: 74%, 84%) and for malignant microcalcifications was 92% (66 of 72; 95% CI: 83%, 97%). For SM plus DBT, the combined reader sensitivity for all microcalcifications was 75% (215 of 288; 95% CI: 69%, 80%) and for malignant microcalcifications was 94% (68 of 72; 95% CI: 86%, 98%). For FFDM, the combined reader specificity for all microcalcifications was 98% (78 of 80; 95% CI: 91%, 100%) and for malignant microcalcifications was 98% (78 of 80; 95% CI: 91%, 100%). For SM plus DBT, combined reader specificity for all microcalcifications was 95% (76 of 80; 95% CI: 88%, 99%) and for malignant microcalcifications was 95% (76 of 80; 95% CI: 88%, 99%). Mixed-effects model concluded no differences between modalities (‒0.03; 95% CI: ‒0.08, 0.01; P = .13). Conclusion Relative to full-field digital mammography, synthetic mammography plus digital breast tomosynthesis had similar sensitivity and specificity for the detection of microcalcifications previously identified for recall at screening mammography. © RSNA, 2018 See also the editorial by Bae and Moon in this issue.


Asunto(s)
Enfermedades de la Mama/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Mamografía/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Adulto , Anciano , Mama/diagnóstico por imagen , Femenino , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
10.
Radiology ; 286(3): 822-829, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29072981

RESUMEN

Purpose To evaluate the effect of background parenchymal enhancement (BPE) on breast magnetic resonance (MR) imaging interpretive performance in a large multi-institutional cohort with independent analysis of screening and diagnostic MR studies. Materials and Methods Analysis of 3770 breast MR studies was conducted. Examinations were performed in 2958 women at six participating facilities in the San Francisco Bay Area from January 2010 to October 2012. Findings were recorded prospectively in the San Francisco Mammography Registry. Performance measures were compared between studies with low BPE (mild or minimal) and those with high BPE (moderate or marked) by using binomial tests of proportions. Results Of 1726 MR imaging studies in the screening group, 1301 were classified as having low BPE and 425 were classified as having high BPE (75% vs 25%, respectively; P < .001). Of 2044 MR imaging studies in the diagnostic group, 1443 were classified as having low BPE and 601 were classified as having high BPE (71% vs 29%, respectively; P < .001). For low versus high BPE groups at screening, abnormal interpretation rate was 157 of 1301 versus 111 of 424 (12% vs 26%, P < .001); biopsy recommendation rate was 85 of 1301 versus 54 of 424 (7% vs 13%, P < .001); and specificity was 89% (95% confidence interval [CI]: 87, 91) versus 75% (95% CI: 71, 80) (P = .01). For the low versus high BPE groups at diagnostic MR imaging, biopsy recommendation rate was 325 of 1443 versus 195 of 601 (23% vs 32%, P < .001); and specificity was 86% (95% CI: 84, 88) versus 75% (95% CI: 74, 82) (P < .001). There were no significant differences between studies with low versus high BPE in sensitivity for screening (76% [95% CI: 55, 91] vs 83% [95% CI: 52, 98]; P = .94) or diagnostic (93% [95% CI: 87, 97] vs 96% [95% CI: 87, 99]; P = .69) MR imaging, nor were there significant differences in cancer detection rate per 1000 patients between the low BPE versus high BPE groups for screening (15 per 1000 vs 24 per 1000, P = .30) or diagnostic (78 per 1000 vs 85 per 1000, P = .64) MR imaging. Conclusion Relative to MR studies with minimal or mild BPE, those with moderate or marked BPE were associated with higher abnormal interpretation and biopsy rates and lower specificity, with no difference in cancer detection rate. © RSNA, 2017 Online supplemental material is available for this article.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Tejido Parenquimatoso/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Biopsia/estadística & datos numéricos , Neoplasias de la Mama/patología , Femenino , Humanos , Tamizaje Masivo/métodos , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros , Sensibilidad y Especificidad , Adulto Joven
11.
AJR Am J Roentgenol ; 210(2): 264-270, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29064760

RESUMEN

OBJECTIVE: Breast cancer is an important health problem for women 40-49 years old, yet screening mammography for this age group remains controversial. This article reviews recent guidelines and supporting evidence on screening mammography in women of this age group. CONCLUSION: Evidence supports the benefit of annual screening mammography in women 40-49 years old. Models of different breast cancer screening strategies consistently show the greatest breast cancer mortality reduction and life-years gained with annual screening starting when women reach 40 years old.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mamografía/normas , Tamizaje Masivo , Adulto , Neoplasias de la Mama/epidemiología , Detección Precoz del Cáncer , Medicina Basada en la Evidencia , Femenino , Humanos , Incidencia , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Estados Unidos/epidemiología
12.
AJR Am J Roentgenol ; 210(4): 927-934, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29489404

RESUMEN

OBJECTIVE: The purpose of this study is to determine the frequency of correlation of sonographic and MRI findings after percutaneous sampling of presumed ultrasound correlates to suspicious lesions detected on breast MRI and to describe our initial experiences with limited-sequence MRI for postprocedural clip verification. MATERIALS AND METHODS: Between January 1, 2014, and March 31, 2016, a total of 1947 contrast-enhanced breast MRI examinations were performed, and 245 targeted ultrasound examinations were conducted to identify correlates to suspicious MRI findings. We retrospectively identified all lesions that underwent ultrasound-guided sampling of a presumed sonographic correlate and for which a subsequent postprocedural limited-sequence unenhanced MR image for clip localization was available. This consisted of a T1-weighted non-fat-saturated and a T2-weighted fat-saturated sequence. Frequencies of sonographic-MRI correlation were quantified. RESULTS: The study cohort consisted of 35 patients with 38 presumed correlates that underwent ultrasound-guided sampling with postprocedural MRI for clip verification. The mean time from percutaneous sampling to postprocedural MRI examination was 1 day. Ten presumed sonographic correlates (26%) were found to localize to a site distinct from the lesion originally identified on MRI. One of these discordant cases revealed malignancy on subsequent MRI-guided biopsy, whereas the presumed sonographic correlate was found to be benign. No patient or lesion characteristics were associated with significantly different frequencies of correlation. CONCLUSION: In our initial experiences with MRI performed for postprocedural clip verification, 26% of presumed correlates to suspicious lesions detected on MRI were not the actual correlate, and 10% of these discordant cases ultimately revealed malignancy. Radiologists should take caution presuming that lesions identified on ultrasound actually represent the suspicious lesions detected on MRI. MRI for clip verification may be useful if ultrasound-guided sampling is pursued.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Cuerpos Extraños/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Instrumentos Quirúrgicos , Ultrasonografía Mamaria/métodos , Adulto , Anciano , Neoplasias de la Mama/patología , Medios de Contraste , Femenino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos
13.
Breast J ; 24(6): 1038-1042, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30240068

RESUMEN

While breast cancer most commonly presents as a screen-detected mammographic finding or a breast symptom, in very rare instances it may first present as a paraneoplastic neurologic syndrome (PNS; Surg Case Rep, 2015;1:59; Ann Neurol 2004;56:715). Fewer than 1% of breast cancer patients have PNS, and an even smaller percentage initially present with neurologic symptoms (J Neurol Neurosurg Psychiatry, 2004;75:ii43). We report a case series of three patients who presented with neurological disorders suspicious for PNS, and were subsequently found to have underlying breast cancer. We follow this with a discussion of key clinical features of management considerations in paraneoplastic syndromes secondary to breast malignancy.


Asunto(s)
Encéfalo/diagnóstico por imagen , Neoplasias de la Mama/patología , Metástasis Linfática/diagnóstico , Síndromes Paraneoplásicos del Sistema Nervioso/etiología , Encéfalo/patología , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/terapia , Carcinoma Intraductal no Infiltrante/diagnóstico , Carcinoma Intraductal no Infiltrante/terapia , Femenino , Humanos , Metástasis Linfática/patología , Imagen por Resonancia Magnética , Mastectomía , Persona de Mediana Edad , Síndromes Paraneoplásicos del Sistema Nervioso/terapia
15.
AJR Am J Roentgenol ; 209(2): 442-453, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28537753

RESUMEN

OBJECTIVE: The majority of MRI-guided breast biopsies yield benign pathology. The purpose of this article is to provide a comprehensive overview of benign pathologic entities commonly encountered at MRI-guided breast biopsy. CONCLUSION: Proper radiologic-pathologic correlation is an integral component of MRI-guided breast biopsy. Familiarity with the spectrum of MRI findings and key histopathologic features of common benign entities will enhance the radiologist's confidence in determining concordance and lead to improved patient management recommendations.


Asunto(s)
Enfermedades de la Mama/diagnóstico por imagen , Enfermedades de la Mama/patología , Biopsia Guiada por Imagen , Imagen por Resonancia Magnética Intervencional , Diagnóstico Diferencial , Femenino , Humanos , Sensibilidad y Especificidad
16.
AJR Am J Roentgenol ; 207(4): 918-924, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27385404

RESUMEN

OBJECTIVE: The objective of the present study is to evaluate the effect of comparison with multiple prior mammograms on the outcomes of screening mammography relative to comparison with a single prior mammogram. MATERIALS AND METHODS: We retrospectively analyzed 46,288 consecutive screening mammograms performed at our institution for 22,792 women. We divided these examinations into three groups: those interpreted without comparison with prior mammograms, those interpreted in comparison with one prior examination, and those interpreted in comparison with two or more prior examinations. For each group, we determined the rate of examination recall. We also calculated the positive predictive value of recall (i.e., positive predictive value level 1 [PPV1]) and the cancer detection rate (CDR) for both the group of examinations compared with a single prior mammogram and the group compared with multiple prior mammograms. Generalized estimating equations with the logistic link function were used to determine the relative odds ratio of recall as a function of the number of comparisons, with adjustment made for age as a confounding variable. The Fisher exact test was performed to compare the PPV1 and the CDR in the different cohorts. RESULTS: The recall rate for mammograms interpreted without comparison with prior examinations was 16.6%, whereas that for mammograms compared with one prior examination was 7.8% and that for mammograms compared with two or more prior examinations was 6.3%. After adjustment was made for age, the odds ratio of recall for the group with multiple prior examinations relative to the group with a single prior examination was 0.864 (95% CI, 0.776-0.962; p = 0.0074). Statistically significant increases in the PPV1 of 0.05 (p = 0.0009) and in the CDR of 2.3 cases per 1000 examinations (p = 0.0481) were also noted for mammograms compared with multiple prior examinations relative to those compared with a single prior examination. CONCLUSION: Comparison with two or more prior mammograms resulted in a statistically significant reduction in the screening mammography recall rate and increases in the CDR and PPV1 relative to comparison with a single prior mammogram.

17.
AJR Am J Roentgenol ; 204(2): 257-60, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25615746

RESUMEN

OBJECTIVE. The purpose of this article is describe the origins and provisions of breast density legislation and to evaluate these mandates with regard to the balance between the potential benefit of supplementary screening and the substantial risk of false-positive findings and the adjunctive tests they necessitate. CONCLUSION. Many states have passed breast density notification legislation, and federal legislation is pending. These mandates present a number of challenges for patients and physicians. There is no consensus regarding the need for supplementary testing solely because a woman has dense breasts. The failure of density legislation to require insurance coverage in many states further complicates implementation of the mandates.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Mama/patología , Detección Precoz del Cáncer/economía , Responsabilidad Legal , Mecanismo de Reembolso , Revelación de la Verdad , Femenino , Humanos
18.
Breast J ; 21(5): 538-42, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26148173

RESUMEN

To review the imaging and pathologic features of a series of lesions detected at digital breast tomosynthesis (DBT), which are occult to conventional digital mammography (DM). We retrospectively reviewed 268 consecutive breast imaging reporting and data system 4 and 5 lesions imaged with both DM and DBT at our facility from July 2012 through April 2013. For each lesion, we recorded the mammographic finding, breast density, mode of biopsy, and pathology results. A total of 19 lesions were identified at DBT that were occult to DM. Sixty three percent (12/19) of these lesions were identified in dense breasts. Architectural distortion was seen in 74% (14/19) of cases and spiculated masses accounted for the remaining 26% (5/19). The positive predictive value of biopsy was 53% (10/19). Seven cases were infiltrating ductal carcinomas and three were infiltrating lobular carcinomas. High-risk lesions accounted for 47% (9/19) of the lesions, the majority of which were radial scars 67% (6/9). Eighty four percent (16/19) of the lesions underwent ultrasound guided core biopsy while the remainder underwent magnetic resonance imaging guided core biopsy. DBT may demonstrate suspicious lesions that are occult to DM, particularly in women with dense breasts. Such lesions have a high likelihood of malignancy and warrant biopsy.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Intensificación de Imagen Radiográfica/métodos , Detección Precoz del Cáncer/métodos , Femenino , Humanos , Invasividad Neoplásica , Estadificación de Neoplasias , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Ultrasonografía Mamaria
19.
Radiol Clin North Am ; 62(4): 559-569, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38777533

RESUMEN

Interval breast cancers are not detected at routine screening and are diagnosed in the interval between screening examinations. A variety of factors contribute to interval cancers, including patient and tumor characteristics as well as the screening technique and frequency. The interval cancer rate is an important metric by which the effectiveness of screening may be assessed and may serve as a surrogate for mortality benefit.


Asunto(s)
Neoplasias de la Mama , Detección Precoz del Cáncer , Mamografía , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Detección Precoz del Cáncer/métodos , Femenino , Mamografía/métodos , Tamizaje Masivo/métodos , Factores de Tiempo
20.
J Breast Imaging ; 6(3): 232-237, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38190264

RESUMEN

There are important differences in the performance and outcomes of breast cancer screening in the prevalent compared to the incident screening rounds. The prevalent screen is the first screening examination using a particular imaging technique and identifies pre-existing, undiagnosed cancers in the population. The incident screen is any subsequent screening examination using that technique. It is expected to identify fewer cancers than the prevalent screen because it captures only those cancers that have become detectable since the prior screening examination. The higher cancer detection rate at prevalent relative to incident screening should be taken into account when analyzing the medical audit and effectiveness of new screening technologies.


Asunto(s)
Neoplasias de la Mama , Detección Precoz del Cáncer , Mamografía , Humanos , Neoplasias de la Mama/epidemiología , Neoplasias de la Mama/diagnóstico , Detección Precoz del Cáncer/métodos , Femenino , Mamografía/estadística & datos numéricos , Mamografía/métodos , Incidencia , Prevalencia , Tamizaje Masivo/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA