Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Europace ; 19(4): 588-595, 2017 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-28431058

RESUMEN

AIMS: The aim of this study was to evaluate any benefits to the number of viable pacing vectors and maximal spatial coverage with quadripolar left ventricular (LV) leads when compared with tripolar and bipolar equivalents in patients receiving cardiac resynchronization therapy (CRT). METHODS AND RESULTS: A meta-analysis of five previously published clinical trials involving the Quartet™ LV lead (St Jude Medical, St Paul, MN, USA) was performed to evaluate the number of viable pacing vectors defined as capture thresholds ≤2.5 V and no phrenic nerve stimulation and maximal spatial coverage of viable vectors in CRT patients at pre-discharge (n = 370) and first follow-up (n = 355). Bipolar and tripolar lead configurations were modelled by systematic elimination of two and one electrode(s), respectively, from the Quartet lead. The Quartet lead with its four pacing electrodes exhibited the greatest number of pacing vectors per patient when compared with the best bipolar and the best tripolar modelled equivalents. Similarly, the Quartet lead provided the highest spatial coverage in terms of the distance between two furthest viable pacing cathodes when compared with the best bipolar and the best tripolar configurations (P < 0.05). Among the three modelled bipolar configurations, the lead configuration with the two most distal electrodes resulted in the highest number of viable pacing vectors. Among the four modelled tripolar configurations, elimination of the second proximal electrode (M3) resulted in the highest number of viable pacing options per patient. There were no significant differences observed between pre-discharge and first follow-up analyses. CONCLUSION: The Quartet lead with its four electrodes and the capability to pace from four anatomical locations provided the highest number of viable pacing vectors at pre-discharge and first follow-up visits, providing more flexibility in device programming and enabling continuation of CRT in more patients when compared with bipolar and tripolar equivalents.


Asunto(s)
Desfibriladores Implantables/estadística & datos numéricos , Electrodos Implantados/estadística & datos numéricos , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/prevención & control , Marcapaso Artificial/estadística & datos numéricos , Terapia Asistida por Computador/instrumentación , Terapia Asistida por Computador/estadística & datos numéricos , Anciano , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Ventrículos Cardíacos , Humanos , Masculino , Prevalencia , Resultado del Tratamiento
2.
Europace ; 19(10): 1700-1709, 2017 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-27738070

RESUMEN

AIMS: In times of evolving cardiac resynchronization therapy, intra-procedural characterization of left ventricular (LV) mechanical activation patterns is desired but technically challenging with currently available technologies. In patients with normal systolic function, we evaluated the feasibility of characterizing LV wall motion using a novel sensor-based, real-time tracking technology. METHODS AND RESULTS: Ten patients underwent simultaneous motion and electrical mapping of the LV endocardium during sinus rhythm using electroanatomical mapping and navigational systems (EnSite™ NavX™ and MediGuide™, SJM). Epicardial motion data were also collected simultaneously at corresponding locations from accessible coronary sinus branches. Displacements at each mapping point and times of electrical and mechanical activation were combined over each of the six standard LV wall segments. Mechanical activation timing was compared with that from electrical activation and preoperative 2D speckle tracking echocardiography (echo). MediGuide-based displacement data were further analysed to estimate LV chamber volumes that were compared with echo and magnetic resonance imaging (MRI). The lateral and septal walls exhibited the largest (12.5 [11.6-15.0] mm) and smallest (10.2 [9.0-11.3] mm) displacement, respectively. Radial displacement was significantly larger endocardially than epicardially (endo: 6.7 [5.0-9.1] mm; epi: 3.8 [2.4-5.6] mm), while longitudinal displacement was significantly larger epicardially (endo: 8.0 [5.0-10.6] mm; epi: 10.3 [7.4-13.8] mm). Most often, the anteroseptal/anterior and lateral walls showed the earliest and latest mechanical activations, respectively. 9/10 patients had concordant or adjacent wall segments of latest mechanical and electrical activation, and 6/10 patients had concordant or adjacent wall segments of latest mechanical activation as measured by MediGuide and echo. MediGuide's LV chamber volumes were significantly correlated with MRI (R2= 0.73, P < 0.01) and echo (R2= 0.75, P < 0.001). CONCLUSION: The feasibility of mapping-guided intra-procedural characterization of LV wall motion was established. CLINICAL TRIAL REGISTRATION: http://www.clinicaltrials.gov; Unique identifier: CT01629160.


Asunto(s)
Potenciales de Acción , Fenómenos Electromagnéticos , Monitoreo Ambulatorio/instrumentación , Telemetría/instrumentación , Transductores , Función Ventricular Izquierda , Anciano , Ecocardiografía , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Estudios de Factibilidad , Femenino , Frecuencia Cardíaca , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Monitoreo Ambulatorio/métodos , Proyectos Piloto , Valor Predictivo de las Pruebas , Estudios Prospectivos , Volumen Sistólico , Sístole , Telemetría/métodos , Factores de Tiempo
3.
J Cardiovasc Electrophysiol ; 25(1): 87-93, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24118580

RESUMEN

INTRODUCTION: Cardiac resynchronization therapy implants entail significant radiation exposure for patients and physicians. A novel 3D electromagnetic cardiovascular navigation system (MediGuide™) was designed to superimpose the real-time location of sensors embedded in delivery tools on prerecorded coronary sinus (CS) venograms while adjusting for patient movement and variations in heart rate under different C-arm angulations. We studied the accuracy and efficacy of MediGuide™ in reducing radiation exposure during LV lead implants. METHODS AND RESULTS: Fluoroscopy durations and radiation exposures were measured in 6 canines undergoing both conventional and MediGuide™-guided LV lead implants. The in vivo accuracy of MediGuide™ was evaluated by obtaining CS venograms at 3 different C-arm angulations at 3 different heart rates and measuring the separation between the projected sensor icon of a MediGuide™ sensor-enabled guidewire and the encompassing branch on prerecorded venograms. RESULTS: Mediguide™-guided implants resulted in significant reductions in fluoroscopy time (52 ± 120 [median 6] vs 129 ± 118 [median 90] sec, P < 0.001) and radiation exposure (13.8 ± 32.4 [median 1.7] vs 49.2 ± 45.3 [median 27.2] µGym(2) , P = 0.03) compared to conventional implants. LV lead delivery time was not significantly different between the 2 implant techniques (P = 0.27). The mean separation between the projected guidewire sensor icon and its encompassing branch was 0.48 ± 0.94 (median 0.00) mm. System accuracy was not affected by variations in heart rate or C-arm angulations. CONCLUSION: The novel 3D cardiovascular navigation system enabled accurate and reliable tracking of sensor-enabled tools at varying heart rates and C-arm angulations with minimal need for fluoroscopy guidance, significantly reducing fluoroscopy time and radiation exposure.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables , Fluoroscopía/métodos , Imagenología Tridimensional/métodos , Dosis de Radiación , Animales , Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables/efectos adversos , Perros , Femenino , Fluoroscopía/efectos adversos , Fluoroscopía/instrumentación , Imagenología Tridimensional/efectos adversos , Imagenología Tridimensional/instrumentación , Masculino
4.
Am J Physiol Lung Cell Mol Physiol ; 304(1): L17-28, 2013 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-23043077

RESUMEN

Pulmonary artery (PA) stenosis is a difficult obstructive defect to manage since clinicians cannot know a priori which obstructions to treat and when. Prognosis of PA stenosis and its chronic effects on lung development are poorly understood. This study aimed to characterize the hemodynamic and structural effects of PA stenosis during development. Fourteen male Sprague-Dawley rats underwent left PA (LPA) banding at age 21 days, and 13 underwent sham operation. Hemodynamic and structural impacts were studied longitudinally at 20, 36, 52, 100, and 160 days. Chronic LPA banding resulted in a significant reduction in LPA flow (P < 0.0001) and size of both proximal LPA (P < 0.0001) and distal LPA (P < 0.01), as well as a significant increase in flow and size of the right PA (P < 0.05) throughout development. Flows and sizes adapted such that normal levels of wall shear were restored after banding. At 160 days, LPA banding resulted in a significant decrease in left lung volume and an increase in right lung volume but no significant differences in total lung volume. There was an elevation of proximal LPA pressure as well as right ventricular hypertrophy in the banded animals. The banded lung exhibited arterial disorganization, loss of vessels, and enlargement of its bronchial arteries, whereas the contralateral lung showed signs of vascular pathology. There are consequences on development of both lungs in the presence of an LPA stenosis at young age. These results suggest that early intervention may be necessary to optimize left lung growth and minimize right lung vascular pathology.


Asunto(s)
Pulmón/crecimiento & desarrollo , Arteria Pulmonar/patología , Circulación Pulmonar , Estenosis de la Válvula Pulmonar/fisiopatología , Animales , Hemodinámica , Hipertrofia Ventricular Derecha/patología , Ligadura , Masculino , Arteria Pulmonar/fisiopatología , Ratas , Ratas Sprague-Dawley
5.
Microvasc Res ; 83(2): 146-53, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22230111

RESUMEN

Understanding mechanisms causing pulmonary vascular disease (PVD) frequently requires a thorough understanding of the underlying structural changes in the pulmonary circulation. Animal models have been used extensively to study different forms of PVD but conventional experimental techniques are limited in their ability to allow the study of the whole pulmonary vasculature at once. In this study, we introduce novel techniques of arterial casting, high-resolution imaging and tree analysis to study the pulmonary circulation in rodent models. Male Sprague-Dawley rats were used at 20, 36, 52, 100 and 160 days of age. A technique involving arterial casting with Microfil silicone polymer, high-resolution micro-computed tomography (micro-CT) at 12.5 µm resolution and image data analysis involving segmentation and skeletonization was developed to both qualitatively and quantitatively describe the changes in the pulmonary vasculature with increasing age. Parameters identified to affect the quality of pulmonary arterial casting included polymer flow rate, total injected volume, polymer viscosity and polymerization time. By optimizing these parameters, we successfully created arterial casts of the pulmonary circulation in rats of different ages and demonstrated the feasibility of quantitatively characterizing the changes in the number of vessels with postnatal growth. These preliminary data suggest that the number of vessels with lumen diameters of 50-200 µm increases rapidly in both lungs between 52 and 100 days of age. With this new technique, the pulmonary vasculature can now be studied in a whole lung animal model to better understand the global effects of disease on vascular structure.


Asunto(s)
Molde por Corrosión , Procesamiento de Imagen Asistido por Computador , Arteria Pulmonar/crecimiento & desarrollo , Microtomografía por Rayos X , Factores de Edad , Envejecimiento , Animales , Estudios de Factibilidad , Inyecciones , Masculino , Modelos Anatómicos , Modelos Cardiovasculares , Arteria Pulmonar/anatomía & histología , Arteria Pulmonar/diagnóstico por imagen , Ratas , Ratas Sprague-Dawley , Elastómeros de Silicona/química , Factores de Tiempo , Viscosidad
6.
Arterioscler Thromb Vasc Biol ; 31(4): 814-20, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21233449

RESUMEN

OBJECTIVE: The G-protein-coupled receptor APJ and its ligand apelin are highly expressed in the pulmonary vasculature, but their function in this vascular bed is unclear. We hypothesized that disruption of apelin signaling would lead to worsening of the vascular remodeling associated with pulmonary hypertension (PH). METHODS AND RESULTS: We found that apelin-null mice developed more severe PH compared with wild-type mice when exposed to chronic hypoxia. Micro-computed tomography of the pulmonary arteries demonstrated significant pruning of the microvasculature in the apelin-null mice. Apelin-null mice had a significant reduction of serum nitrate levels. This was secondary to downregulation of endothelial nitric oxide synthase (eNOS), which was associated with reduced expression of Kruppel-like factor 2 (KLF2), a known regulator of eNOS expression. In vitro knockdown studies targeting apelin in human pulmonary artery endothelial cells demonstrated decreased eNOS and KLF2 expression, as well as impaired phosphorylation of AMP-activated kinase and eNOS. Moreover, serum apelin levels of patients with PH were significantly lower than those of controls. CONCLUSIONS: These data demonstrate that disruption of apelin signaling can exacerbate PH mediated by decreased activation of AMP-activated kinase and eNOS, and they identify this pathway as a potentially important therapeutic target for treatment of this refractory human disease.


Asunto(s)
Proteínas Portadoras/metabolismo , Hipertensión Pulmonar/etiología , Hipoxia/complicaciones , Péptidos y Proteínas de Señalización Intercelular/metabolismo , Arteria Pulmonar/metabolismo , Receptores Acoplados a Proteínas G/metabolismo , Transducción de Señal , Proteínas Quinasas Activadas por AMP/metabolismo , Adipoquinas , Adulto , Animales , Apelina , Receptores de Apelina , Proteínas Portadoras/genética , Estudios de Casos y Controles , Células Cultivadas , Modelos Animales de Enfermedad , Femenino , Humanos , Hipertensión Pulmonar/diagnóstico por imagen , Hipertensión Pulmonar/genética , Hipertensión Pulmonar/metabolismo , Hipertensión Pulmonar/fisiopatología , Hipoxia/genética , Hipoxia/metabolismo , Péptidos y Proteínas de Señalización Intercelular/genética , Factores de Transcripción de Tipo Kruppel/metabolismo , Masculino , Ratones , Ratones de la Cepa 129 , Ratones Noqueados , Persona de Mediana Edad , Óxido Nítrico/metabolismo , Óxido Nítrico Sintasa de Tipo III/metabolismo , Fosforilación , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/fisiopatología , Receptores Acoplados a Proteínas G/sangre , Índice de Severidad de la Enfermedad , Microtomografía por Rayos X
7.
Am J Physiol Lung Cell Mol Physiol ; 301(3): L368-79, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21665961

RESUMEN

Malformations of the pulmonary arteries can increase right heart workload and result in morbidity, heart failure, and death. With the increased use of murine models to study these malformations, there is a pressing need for an accurate and noninvasive experimental technique that is capable of characterizing pulmonary arterial hemodynamics in these animals. We describe the growth trends of pulmonary arteries in 13 male Sprague-Dawley rats at 20, 36, 52, 100, and 160 days of age with the introduction of phase-contrast MRI as such a technique. PCMRI results correlated closely with cardiac output measurements by ultrasound echocardiography and with fluorescent microspheres in right-left lung flow split (flow partition). Mean flow, average cross-sectional area, distensibility, and shear rates for the right and left pulmonary arteries (RPA and LPA) were calculated. The RPA was larger and received more flow at all times than the LPA (P < 0.0001). Right-left flow split did not change significantly with age, and arterial distensibility was not significantly different between RPA and LPA, except at 160 days (P < 0.01). Shear rates were much higher for the LPA than the RPA (P < 0.0001) throughout development. The RPA and LPA showed different structure-function relationships but obeyed similar allometric scaling laws, with scaling exponents comparable to those of the main pulmonary artery. This study is the first to quantitatively describe changes in RPA and LPA flows and sizes with development and to apply phase-contrast MRI techniques to pulmonary arteries in rats.


Asunto(s)
Arteria Pulmonar/crecimiento & desarrollo , Animales , Velocidad del Flujo Sanguíneo , Gasto Cardíaco , Ecocardiografía , Frecuencia Cardíaca , Imagen por Resonancia Magnética/métodos , Masculino , Arteria Pulmonar/fisiopatología , Ratas , Ratas Sprague-Dawley
8.
J Interv Card Electrophysiol ; 51(3): 205-214, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29388068

RESUMEN

PURPOSE: Cardiac disease frequently has a degenerative effect on cardiac pump function and regional myocardial contraction. Therefore, an accurate assessment of regional wall motion is a measure of the extent and severity of the disease. We sought to further validate an intra-operative, sensor-based technology for measuring wall motion and strain by characterizing left ventricular (LV) mechanical and electrical activation patterns in patients with normal (NSF) and impaired systolic function (ISF). METHODS: NSF (n = 10; ejection fraction = 62.9 ± 6.1%) and ISF (n = 18; ejection fraction = 35.1 ± 13.6%) patients underwent simultaneous electrical and motion mapping of the LV endocardium using electroanatomical mapping and navigational systems (EnSite™ NavX™ and MediGuide™, Abbott). Motion trajectories, strain profiles, and activation times were calculated over the six standard LV walls. RESULTS: NSF patients had significantly greater motion and systolic strains across all LV walls than ISF patients. LV walls with low-voltage areas showed less motion and systolic strain than walls with normal voltage. LV electrical dyssynchrony was significantly smaller in NSF and ISF patients with narrow-QRS complexes than ISF patients with wide-QRS complexes, but mechanical dyssynchrony was larger in all ISF patients than NSF patients. The latest mechanical activation was most often the lateral/posterior walls in NSF and wide-QRS ISF patients but varied in narrow-QRS ISF patients. CONCLUSIONS: This intra-operative technique can be used to characterize LV wall motion and strain in patients with impaired systolic function. This technique may be utilized clinically to provide individually tailored LV lead positioning at the region of latest mechanical activation for patients undergoing cardiac resynchronization therapy. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01629160.


Asunto(s)
Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas , Mapeo Epicárdico/métodos , Interpretación de Imagen Asistida por Computador , Volumen Sistólico/fisiología , Anciano , Fibrilación Atrial/diagnóstico , Terapia de Resincronización Cardíaca/métodos , Ablación por Catéter/métodos , Electrocardiografía Ambulatoria/métodos , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio/métodos , Contracción Miocárdica/fisiología , Selección de Paciente , Recuperación de la Función , Valores de Referencia , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA