RESUMEN
PURPOSE: We sought to define how changes in position and rotation of fluoroscopic imaging may affect the assessment of condylar widening intraoperatively. METHODS: Thirty-three patients with tibial plateau fractures were prospectively identified and included in this study. Fluoroscopic images of the uninjured tibial plateau were obtained in (1) full extension and (2) slight flexion on foam ramp. Beginning with a plateau view, additional views of the tibial plateau were then obtained by rotating the fluoroscope around the knee in 5 degree increments up to 15 degrees in both internal and external rotation. Measurements of distal femoral condylar width (DFW), distal femoral articular width (FAW), proximal tibial articular width (TAW) and lateral plateau width (LPW) were performed. RESULTS: LPW was decreased in flexion compared to extension at all degrees of rotation (p = 0.04-0.00001). There was a trend toward increasing LPW with increasing degrees of internal rotation which reached significance at 15Ë of internal rotation when the knee was flexed. On ANOVA, there was a significant difference of LPW with increasing degree of internal rotation when the knee was in flexion (p = 0.008), but not in extension. There were no differences in DFW, FAW, TAW and DFW/TAW at any point though LPW was decreased in flexion at all degrees of rotation. The FAW/TAW ratio was increased in flexion at all degrees of rotation. DISCUSSION: The knee in flexion will underestimate the measurement of condylar width compared to the knee in full extension, by ~ 2 mm. Rotation of the knee, in comparison, did not have a significant effect on condylar width assessment. LEVEL OF EVIDENCE: Diagnostic II.
Asunto(s)
Articulación de la Rodilla , Tibia , Humanos , Fenómenos Biomecánicos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Tibia/diagnóstico por imagen , Tibia/cirugía , Fémur/cirugía , Rango del Movimiento ArticularRESUMEN
BACKGROUND: Irreparable posterosuperior rotator cuff tears cause pain and impaired shoulder function. Latissimus dorsi (LD) transfer has been proven to improve shoulder function, but lower trapezius (LT) transfer has recently been proposed as an alternative. This study aimed to compare the biomechanics of LD and LT transfers and how they are affected by different insertion sites. METHODS: The Newcastle shoulder model was used to investigate the biomechanics of these 2 tendon transfers. Computed tomography data sets from 10 healthy subjects were used to customize the model, and virtual LD and LT transfers were performed on supraspinatus, infraspinatus, and teres minor insertion sites. Muscle moment arms and lengths were computed for abduction, forward flexion, and external rotation. RESULTS: The LT yields greater abduction moment arms compared with the LD when it is transferred to the native supraspinatus and infraspinatus insertion sites. However, they become adductors when transferred to the native teres minor insertion. Both muscles show strong external rotation moment arms, except for the LT with a supraspinatus insertion. Resting muscle strains were 0.21 (±0.03), 0.12 (±0.02), and 0.06 (±0.03) for the LD and 0.70 (±0.15), 0.61 (±0.13), and 0.58 (±0.13) for the LT for the supraspinatus, infraspinatus, and teres minor insertions, respectively. CONCLUSIONS: LT provided better abduction and external rotation moment arms when transferred to the infraspinatus insertion. LD performed better when transferred to the supraspinatus insertion. Overall, LT transfer showed a biomechanical advantage compared with LD transfer because of stronger abduction moment arms. However, significantly larger muscle strains after LT transfer necessitate a tendon allograft to prevent muscle overtensioning.
Asunto(s)
Artroplastia/métodos , Rango del Movimiento Articular/fisiología , Lesiones del Manguito de los Rotadores/cirugía , Articulación del Hombro/fisiopatología , Músculos Superficiales de la Espalda/trasplante , Transferencia Tendinosa/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Biológicos , Lesiones del Manguito de los Rotadores/fisiopatología , Articulación del Hombro/cirugíaRESUMEN
BACKGROUND: Version correction via eccentric reaming reduces clinically important retroversion in Walch type B2 glenoids (those with substantial glenoid retroversion and a second, sclerotic neoglenoid cavity) before total shoulder arthroplasty (TSA). Clinically, an increased risk of glenoid component loosening in B2 glenoids was hypothesized to be the result of compromised glenoid bone quality attributable to eccentric reaming. However, no established guidelines exist regarding how much version correction can be applied without compromising the quality of glenoid bone. QUESTIONS/PURPOSES: (1) How does version correction correlate to the reaming depth and the volume of resected bone during eccentric reaming of B2 glenoids? (2) How does version correction affect the density of the remaining glenoid bone? (3) How does version correction affect the spatial distribution of high-quality bone in the remaining glenoid? METHODS: CT scans of 25 patients identified with Walch type B2 glenoids (age, 68 ± 9 years; 14 males, 11 females) were selected from a cohort of 111 patients (age, 69 ± 10 years; 50 males, 61 females) with primary shoulder osteoarthritis who underwent TSA. Virtual TSA with version corrections of 0°, 5°, 10°, and 15° was performed on 25 CT-reconstructed three-dimensional models of B2 scapulae. After simulated eccentric reaming at each version correction angle, bone density (Hounsfield units [HUs]) was analyzed in five adjacent 1-mm layers under the reamed glenoid surface. Remaining high-quality bone (> 650 HUs) distribution in each 1-mm layer at different version corrections was observed on spatial distribution maps. RESULTS: Larger version corrections required more bone resection, especially from the anterior glenoid. Mean bone densities in the first 1-mm bone bed under the reamed surface were lower with 10° (523.3 ± 79.9 HUs) and 15° (479.5 ± 81.0 HUs) version corrections relative to 0° (0°, 609.0 ± 103.9 HUs; mean difference between 0° and 15°, 129.5 HUs [95% CI, 46.3-212.8 HUs], p < 0.001; mean difference between 0° and 10°, 85.7 HUs [95% CI, 8.6-162.9 HUs], p = 0.021) version correction. Similar results were observed for the second 1-mm bone bed. Spatial distribution maps qualitatively showed a decreased frequency of high-quality bone in the anterior glenoid as version correction increased. CONCLUSIONS: A version correction as low as 10° was shown to reduce the density of the glenoid bone bed for TSA glenoid fixation in our computational study that simulated reaming on CT-reconstructed B2 glenoid models. Increased version correction resulted in gradual depletion of high-quality bone from the anterior region of B2 glenoids. CLINICAL RELEVANCE: This computational study of eccentric reaming of the glenoid before TSA quantitatively showed glenoid bone quality is sensitive to version correction via simulated eccentric reaming. The bone density results of our study may benefit surgeons to better plan TSA on B2 glenoids needing durable bone support, and help to clarify goals for development of precision surgical tools.
Asunto(s)
Artroplastia de Reemplazo/métodos , Cavidad Glenoidea/cirugía , Osteoartritis/cirugía , Osteotomía/métodos , Modelación Específica para el Paciente , Articulación del Hombro/cirugía , Cirugía Asistida por Computador , Anciano , Artroplastia de Reemplazo/efectos adversos , Artroplastia de Reemplazo/instrumentación , Densidad Ósea , Femenino , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/fisiopatología , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Osteoartritis/diagnóstico por imagen , Osteoartritis/fisiopatología , Osteotomía/efectos adversos , Diseño de Prótesis , Interpretación de Imagen Radiográfica Asistida por Computador , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/fisiopatología , Prótesis de Hombro , Cirugía Asistida por Computador/efectos adversos , Tomografía Computarizada por Rayos X , Resultado del TratamientoRESUMEN
In the quest to understand the implications of separating management and treatment, we must first examine the forces driving management decisions. By defining ownership and equity interest, we are able to isolate a critical factor in the decision-making process. Evaluating the spectrum of the different models of dentistry gives us insight into potential advantages as well as disadvantages that can arise. In private practice, an owner typically wants to see the business grow over a lifetime, while, on the other end of the spectrum, corporate dental companies may be prioritizing dividends, investment returns through speedy packaged sales, or other means of reporting progress to investors. Interestingly, each model of dentistry has shown strength and growth, but there is no clear path to what is deemed ideal.
Asunto(s)
Administración de la Práctica Odontológica/organización & administración , Rol Profesional , Servicios Contratados , Toma de Decisiones , Práctica Odontológica de Grupo/organización & administración , Humanos , Modelos Organizacionales , Propiedad , Práctica Odontológica Asociada/organización & administraciónRESUMEN
OBJECTIVES: To estimate the prevalence of suboptimal fluoroscopy of sacral outlet images due to anatomic and equipment dimensions. Pelvic retroversion is hypothesized to mitigate this issue. DESIGN: In silico simulations using retrospectively collected computed tomography (CT) data from human patients. SETTING: Level I trauma center. PATIENT SELECTION CRITERIA: Adults with OTA/AO 61 pelvic ring disruptions treated with posterior pelvic fixation between July and December 2021. OUTCOME MEASURES AND COMPARISONS: C-arm tilt angles required to obtain 3 optimal fluoroscopic sacral outlet images, defined as vectors from pubic symphysis to S2 and parallel to the first and second sacral neural foramina, were calculated from sagittal CT images. A suboptimal view was defined as collision of the C-arm radiation source or image intensifier with the patient/operating table at the required tilt angle simulated using the dimensions of 5 commercial C-arm models and trigonometric calculations. Incidence of suboptimal outlet views and pelvic retroversion necessary to obtain optimal views without collision, which may be obtained by placement of a sacral bump, was determined for each view for all patients and C-arm models. RESULTS: CT data from 72 adults were used. Collision between patient and C-arm would occur at the optimal tilt angle for 17% of simulations and at least 1 view in 68% of patients. Greater body mass index was associated with greater odds of suboptimal imaging (standard outlet: odds ratio [OR] 0.84, confidence interval [CI] 0.79-0.89, P < 0.001; S1: OR 0.91, CI 0.87-0.97, P = 0.002; S2: OR 0.85, CI 0.80-0.91, P < 0.001). S1 anterior sacral slope was associated with suboptimal S1 outlet views (OR 1.12, Cl 1.07-1.17, P < 0.001). S2 anterior sacral slope was associated with suboptimal standard outlet (OR 1.07, Cl 1.02-1.13, P = 0.004) and S2 outlet (OR 1.16, Cl 1.09-1.23, P < 0.001) views. Retroversion of the pelvis 15-20 degrees made optimal outlet views possible without collision in 95%-99% of all simulations, respectively. CONCLUSIONS: Suboptimal outlet imaging of the sacrum is associated with greater body mass index and sacral slope at S1 and S2. Retroversion of the pelvis by 15-20 degrees with a bump under the distal sacrum may offer a low-tech solution to ensure optimal fluoroscopic imaging for percutaneous fixation of the posterior pelvic ring. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
Asunto(s)
Huesos Pélvicos , Sacro , Tomografía Computarizada por Rayos X , Humanos , Sacro/diagnóstico por imagen , Fluoroscopía , Masculino , Femenino , Huesos Pélvicos/diagnóstico por imagen , Estudios Retrospectivos , Adulto , Persona de Mediana Edad , Tomografía Computarizada por Rayos X/métodos , Simulación por Computador , Fracturas Óseas/diagnóstico por imagen , AncianoRESUMEN
Bone drilling is a critical skill honed during orthopaedic surgical education. How a bone drill is held and operated (bracing position) may influence drilling performance. Methods: A prospective study with randomized crossover was conducted to assess the effect of 4 bracing positions on orthopaedic surgical trainee performance in a simulated bone drilling task. Linear mixed effects models considering participant training level, preferred bracing position, height, weight, and drill hole number were used to estimate pairwise and overall comparisons of the effect of each bracing position on 2 primary outcomes of drilling depth and accuracy. Results: A total of 42 trainees were screened and 19 were randomized and completed the study. Drill plunge depth with a 1-handed drilling position was significantly greater by pairwise comparison to any of the 3 double handed positions tested: a soft tissue protection sleeve in the other hand (0.41 mm, 95% confidence interval [CI] 0.80-0.03, p = 0.031), a 2-handed position with the contralateral small finger on bone and the thumb on the drill (0.42 mm, 95% CI 0.06-0.79, p = 0.018), and a 2-handed position with the contralateral elbow braced against the table (0.40 mm, 95% CI 0.02-0.78, p = 0.038). No position afforded a significant accuracy advantage (p = 0.227). Interactions of participant height with plunge depth and accuracy as well between drill hole number and plunge depth were observed. Conclusion: Orthopaedic surgical educators should discourage trainees from operating a bone drill using only 1 hand to reduce the risk of iatrogenic injury due to drill plunging. Level of Evidence: Therapeutic Level II.
RESUMEN
OBJECTIVE: To determine individual bilateral differences (IBDs) in tibial torsion in a diverse population. METHODS: Computed tomography scans of uninjured bilateral tibiae were used to determine tibial torsion and IBDs in torsion using 4 measurement methods. Age, sex, and self-identified race/ethnicity were also recorded for each subject. Mean tibial torsion and IBDs in torsion were compared in the overall cohort and when stratified by sex and race/ethnicity. Simple and multiple linear regression models were used to correlate demographic variables with tibial torsion and IBDs in torsion. RESULTS: One hundred ninety-five patients were evaluated. The mean tibial torsion was 27.5 ± 8.3 degrees (range -3 to 47.5 degrees). The mean IBD in torsion was 5.3 ± 4.0 degrees (range 0-23.5 degrees, P < 0.001). 12.3% of patients had IBDs in torsion of ≥10 degrees. In the regression analysis, patients who identified as White had greater average torsion by 4.4 degrees compared with Hispanic/Latinx patients (P = 0.001), whereas age and sex were not significantly associated with absolute torsion. Demographics were not associated with significant differences in IBDs in torsion. CONCLUSIONS: Tibial torsion varies considerably and individual side-to-side differences are common. Race/ethnicity was associated with differences in the magnitude of tibial torsion, but no factors were associated with bilateral differences in torsion. The results of this study may be clinically significant in the context of using the uninjured contralateral limb to help establish rotational alignment during medullary nail stabilization of diaphyseal tibia fractures. In addition, these findings should be considered in the evaluation of tibia rotational malalignment. LEVEL OF EVIDENCE: Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Asunto(s)
Desviación Ósea , Fracturas de la Tibia , Desviación Ósea/diagnóstico por imagen , Estudios de Cohortes , Humanos , Tibia/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Anomalía Torsional/diagnóstico por imagenRESUMEN
Latent membrane protein 1 (LMP1) is an Epstein-Barr virus (EBV) oncogenic protein that has no intrinsic enzymatic activity or sequence homology to cellular or viral proteins. The oncogenic potential of LMP1 has been ascribed to pleiotropic signaling properties initiated through protein-protein interactions in cytosolic membrane compartments, but the effects of LMP1 extend to nuclear and extracellular processes. Although LMP1 is one of the latent genes required for EBV-immortalization of B cells, the biology of LMP1 in the pathogenesis of the epithelial cancer nasopharyngeal carcinoma (NPC) is more complex. NPC is prevalent in specific regions of the world with high incidence in southeast China. The epidemiology and time interval from seroconversion to NPC onset in adults would suggest the involvement of multiple risk factors that complement the establishment of a latent and persistent EBV infection. The contribution of LMP1 to EBV pathogenesis in polarized epithelia has only recently begun to be elucidated. Furthermore, the LMP1 gene has emerged as one of the most divergent sequences in the EBV genome. This review will discuss the significance of recent advances in NPC research from elucidating LMP1 function in epithelial cells and lessons that could be learned from mining LMP1 sequence diversity.
RESUMEN
Understanding the mechanical environment of articular cartilage and chondrocytes is of the utmost importance in evaluating tissue damage which is often related to failure of the fibre architecture and mechanical injury to the cells. This knowledge also has significant implications for understanding the mechanobiological response in healthy and diseased cartilage and can drive the development of intervention strategies, ranging from the design of tissue-engineered constructs to the establishment of rehabilitation protocols. Spanning multiple spatial scales, a wide range of biomechanical factors dictate this mechanical environment. Computational modelling and simulation provide descriptive and predictive tools to identify multiscale interactions, and can lead towards a greater comprehension of healthy and diseased cartilage function, possibly in an individualized manner. Cartilage and chondrocyte mechanics can be examined in silico, through post-processing or feed-forward approaches. First, joint-tissue level simulations, typically using the finite-element method, solve boundary value problems representing the joint articulation and underlying tissue, which can differentiate the role of compartmental joint loading in cartilage contact mechanics and macroscale cartilage field mechanics. Subsequently, tissue-cell scale simulations, driven by the macroscale cartilage mechanical field information, can predict chondrocyte deformation metrics along with the mechanics of the surrounding pericellular and extracellular matrices. A high-throughput modelling and simulation framework is necessary to develop models representative of regional and population-wide variations in cartilage and chondrocyte anatomy and mechanical properties, and to conduct large-scale analysis accommodating a multitude of loading scenarios. However, realization of such a framework is a daunting task, with technical difficulties hindering the processes of model development, scale coupling, simulation and interpretation of the results. This study aims to summarize various strategies to address the technical challenges of post-processing-based simulations of cartilage and chondrocyte mechanics with the ultimate goal of establishing the foundations of a high-throughput multiscale analysis framework. At the joint-tissue scale, rapid development of regional models of articular contact is possible by automating the process of generating parametric representations of cartilage boundaries and depth-dependent zonal delineation with associated constitutive relationships. At the tissue-cell scale, models descriptive of multicellular and fibrillar architecture of cartilage zones can also be generated in an automated fashion. Through post-processing, scripts can extract biphasic mechanical metrics at a desired point in the cartilage to assign loading and boundary conditions to models at the lower spatial scale of cells. Cell deformation metrics can be extracted from simulation results to provide a simplified description of individual chondrocyte responses. Simulations at the tissue-cell scale can be parallelized owing to the loosely coupled nature of the feed-forward approach. Verification studies illustrated the necessity of a second-order data passing scheme between scales and evaluated the role that the microscale representative volume size plays in appropriately predicting the mechanical response of the chondrocytes. The tools summarized in this study collectively provide a framework for high-throughput exploration of cartilage biomechanics, which includes minimally supervised model generation, and prediction of multiscale biomechanical metrics across a range of spatial scales, from joint regions and cartilage zones, down to that of the chondrocytes.