Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 510
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38767244

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

2.
N Engl J Med ; 389(18): 1660-1671, 2023 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-37634148

RESUMEN

BACKGROUND: Catheter-based pulmonary vein isolation is an effective treatment for paroxysmal atrial fibrillation. Pulsed field ablation, which delivers microsecond high-voltage electrical fields, may limit damage to tissues outside the myocardium. The efficacy and safety of pulsed field ablation as compared with conventional thermal ablation are not known. METHODS: In this randomized, single-blind, noninferiority trial, we assigned patients with drug-refractory paroxysmal atrial fibrillation in a 1:1 ratio to undergo pulsed field ablation or conventional radiofrequency or cryoballoon ablation. The primary efficacy end point was freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation. The primary safety end point included acute and chronic device- and procedure-related serious adverse events. RESULTS: A total of 305 patients were assigned to undergo pulsed field ablation, and 302 were assigned to undergo thermal ablation. At 1 year, the primary efficacy end point was met (i.e., no events occurred) in 204 patients (estimated probability, 73.3%) who underwent pulsed field ablation and 194 patients (estimated probability, 71.3%) who underwent thermal ablation (between-group difference, 2.0 percentage points; 95% Bayesian credible interval, -5.2 to 9.2; posterior probability of noninferiority, >0.999). Primary safety end-point events occurred in 6 patients (estimated incidence, 2.1%) who underwent pulsed field ablation and 4 patients (estimated incidence, 1.5%) who underwent thermal ablation (between-group difference, 0.6 percentage points; 95% Bayesian credible interval, -1.5 to 2.8; posterior probability of noninferiority, >0.999). CONCLUSIONS: Among patients with paroxysmal atrial fibrillation receiving a catheter-based therapy, pulsed field ablation was noninferior to conventional thermal ablation with respect to freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation and with respect to device- and procedure-related serious adverse events at 1 year. (Funded by Farapulse-Boston Scientific; ADVENT ClinicalTrials.gov number, NCT04612244.).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/clasificación , Fibrilación Atrial/cirugía , Teorema de Bayes , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Recurrencia , Método Simple Ciego , Taquicardia/etiología , Resultado del Tratamiento
3.
N Engl J Med ; 388(25): 2360-2370, 2023 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-37212442

RESUMEN

BACKGROUND: Single-chamber ventricular leadless pacemakers do not support atrial pacing or consistent atrioventricular synchrony. A dual-chamber leadless pacemaker system consisting of two devices implanted percutaneously, one in the right atrium and one in the right ventricle, would make leadless pacemaker therapy a treatment option for a wider range of indications. METHODS: We conducted a prospective, multicenter, single-group study to evaluate the safety and performance of a dual-chamber leadless pacemaker system. Patients with a conventional indication for dual-chamber pacing were eligible for participation. The primary safety end point was freedom from complications (i.e., device- or procedure-related serious adverse events) at 90 days. The first primary performance end point was a combination of adequate atrial capture threshold and sensing amplitude at 3 months. The second primary performance end point was at least 70% atrioventricular synchrony at 3 months while the patient was sitting. RESULTS: Among the 300 patients enrolled, 190 (63.3%) had sinus-node dysfunction and 100 (33.3%) had atrioventricular block as the primary pacing indication. The implantation procedure was successful (i.e., two functioning leadless pacemakers were implanted and had established implant-to-implant communication) in 295 patients (98.3%). A total of 35 device- or procedure-related serious adverse events occurred in 29 patients. The primary safety end point was met in 271 patients (90.3%; 95% confidence interval [CI], 87.0 to 93.7), which exceeded the performance goal of 78% (P<0.001). The first primary performance end point was met in 90.2% of the patients (95% CI, 86.8 to 93.6), which exceeded the performance goal of 82.5% (P<0.001). The mean (±SD) atrial capture threshold was 0.82±0.70 V, and the mean P-wave amplitude was 3.58±1.88 mV. Of the 21 patients (7%) with a P-wave amplitude of less than 1.0 mV, none required device revision for inadequate sensing. At least 70% atrioventricular synchrony was achieved in 97.3% of the patients (95% CI, 95.4 to 99.3), which exceeded the performance goal of 83% (P<0.001). CONCLUSIONS: The dual-chamber leadless pacemaker system met the primary safety end point and provided atrial pacing and reliable atrioventricular synchrony for 3 months after implantation. (Funded by Abbott Medical; Aveir DR i2i ClinicalTrials.gov number, NCT05252702.).


Asunto(s)
Arritmias Cardíacas , Estimulación Cardíaca Artificial , Marcapaso Artificial , Humanos , Fibrilación Atrial/terapia , Fibrilación Atrial/etiología , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Estudios de Seguimiento , Marcapaso Artificial/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Arritmias Cardíacas/terapia
4.
Stroke ; 55(1): 214-225, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38134262

RESUMEN

Nonvalvular atrial fibrillation is a common rhythm disorder of middle-aged to older adults that can cause ischemic strokes and systemic embolism. Lifelong use of oral anticoagulants reduces the risk of these ischemic events but increases the risk of major and clinically relevant hemorrhages. These medications also require strict compliance for efficacy, and they have nontrivial failure rates in higher-risk patients. Left atrial appendage closure is a nonpharmacological method to prevent ischemic strokes in atrial fibrillation without the need for lifelong anticoagulant use, but this procedure has the potential for complications and residual embolic events. This workshop of the Roundtable of Academia and Industry for Stroke Prevention discussed future research needed to further decrease the ischemic and hemorrhagic risks among patients with atrial fibrillation. A direct thrombin inhibitor, factor Xa inhibitors, and left atrial appendage closure are FDA-approved approaches whereas factor XIa inhibitors are currently being studied in phase 3 randomized controlled trials for stroke prevention. The benefits, risks, and shortcomings of these treatments and future research required in different high-risk patient populations are reviewed in this consensus statement.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Embolia , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Persona de Mediana Edad , Humanos , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/complicaciones , Anticoagulantes/uso terapéutico , Embolia/complicaciones , Accidente Cerebrovascular Isquémico/tratamiento farmacológico , Resultado del Tratamiento
5.
Artículo en Inglés | MEDLINE | ID: mdl-38845147

RESUMEN

INTRODUCTION: Prior studies have indicated that the frequency of premature ventricular complexes (PVC) increases after catheter ablation for atrial fibrillation (AF). However, these studies have primarily focused on patients whose PVC burden increased rather than including the full spectrum of outcomes. METHODS AND RESULTS: We performed a single-center retrospective cohort study of consecutive patients who underwent first-time AF ablation from 1/2018 to 12/2022 for paroxysmal or persistent AF and had both preablation and postablation rhythm monitoring within 6 months of the procedure. Patients were excluded if they had prior AF or PVC ablation or were prescribed a class I or III antiarrhythmic medication. Among 2945 patients who underwent AF ablation during the study period, 130 patients underwent first-time AF ablation and received both pre and post ambulatory monitoring. The median PVC burden before ablation was <1%. Most patients (63%) had no change in PVC burden after AF ablation compared with preablation, and patients who had an increase in PVC burden were offset by those with reductions in PVCs. A paired analysis pre- and post-AF ablation showed no significant change in PVC burden (p = .495). CONCLUSION: Although an elevated PVC burden after AF ablation may be seen clinically, the majority of patients have no change in burden. Studies that suggest an increase in PVC burden after AF ablation may suffer from incomplete sample selection and thus omit the important effect of regression to the mean.

6.
J Card Fail ; 2024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38211934

RESUMEN

OBJECTIVE: Splanchnic vasoconstriction augments transfer of blood volume from the abdomen into the thorax, which may increase filling pressures and hemodynamic congestion in patients with noncompliant hearts. Therapeutic interruption of splanchnic nerve activity holds promise to reduce hemodynamic congestion in patients with heart failure with preserved ejection fraction (HFpEF). Here we describe (1) the rationale and design of the first sham-controlled, randomized clinical trial of splanchnic nerve ablation for HFpEF and (2) the 12-month results of the lead-in (open-label) trial's participants. METHODS: REBALANCE-HF is a prospective, multicenter, randomized, double-blinded, sham-controlled clinical trial of endovascular, transcatheter, right-sided greater splanchnic nerve ablation for volume management (SAVM) in patients with HFpEF. The primary objectives are to evaluate the safety and efficacy of SAVM and identify responder characteristics to inform future studies. The trial consists of an open-label lead-in phase followed by the randomized, sham-controlled phase. The primary efficacy endpoint is the reduction in pulmonary capillary wedge pressure (PCWP) at 1-month follow-up compared to baseline during passive leg raise and 20W exercise. Secondary and exploratory endpoints include health status (Kansas City Cardiomyopathy Questionnaire), 6-minute walk test distance, New York Heart Association class, and NTproBNP levels at 3, 6 and 12 months. The primary safety endpoint is device- or procedure-related serious adverse events at the 1-month follow-up. RESULTS: The lead-in phase of the study, which enrolled 26 patients with HFpEF who underwent SAVM, demonstrated favorable safety outcomes and reduction in exercise PCWP at 1 month post-procedure and improvements in all secondary endpoints at 6 and 12 months of follow-up. The randomized phase of the trial (n = 44 SAVM; n = 46 sham) has completed enrollment, and follow-up is ongoing. CONCLUSION: REBALANCE-HF is the first sham-controlled randomized clinical trial of greater splanchnic nerve ablation in HFpEF. Initial 12-month open-label results are promising, and the results of the randomized portion of the trial will inform the design of a future pivotal clinical trial. SAVM may offer a promising therapeutic option for patients with HFpEF. TRIAL REGISTRATION: NCT04592445.

7.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38912887

RESUMEN

AIMS: Pulsed field ablation (PFA) is an emerging non-thermal ablative modality demonstrating considerable promise for catheter ablation of atrial fibrillation (AF). However, these PFA trials have almost universally included only Caucasian populations, with little data on its effect on other races/ethnicities. The PLEASE-AF trial sought to study the 12-month efficacy and the safety of a multi-electrode hexaspline PFA catheter in treating a predominantly Asian/Chinese population of patients with drug-refractory paroxysmal AF. METHODS AND RESULTS: Patients underwent pulmonary vein (PV) isolation (PVI) by delivering different pulse intensities at the PV ostium (1800 V) and atrium (2000 V). Acute success was defined as no PV potentials and entrance/exit conduction block of all PVs after a 20-min waiting period. Follow-up at 3, 6, and 12 months included 12-lead electrocardiogram and 24-h Holter examinations. The primary efficacy endpoint was 12-month freedom from any atrial arrhythmias lasting at least 30 s. The cohort included 143 patients from 12 hospitals treated by 28 operators: age 60.2 ± 10.0 years, 65.7% male, Asian/Chinese 100%, and left atrial diameter 36.6 ± 4.9 mm. All PVs (565/565, 100%) were successfully isolated. The total procedure, catheter dwell, total PFA application, and total fluoroscopy times were 123.5 ± 38.8 min, 63.0 ± 30.7 min, 169.7 ± 34.6 s, and 27.3 ± 10.1 min, respectively. The primary endpoint was observed in 124 of 143 patients (86.7%). One patient (0.7%) developed a small pericardial effusion 1-month post-procedure, not requiring intervention. CONCLUSION: The novel hexaspline PFA catheter demonstrated universal acute PVI with an excellent safety profile and promising 12-month freedom from recurrent atrial arrhythmias in an Asian/Chinese population with paroxysmal AF. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05114954.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Anciano , Resultado del Tratamiento , Pueblo Asiatico , China , Catéteres Cardíacos , Recurrencia , Electrocardiografía Ambulatoria , Factores de Tiempo , Diseño de Equipo , Frecuencia Cardíaca , Potenciales de Acción
8.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38582974

RESUMEN

AIMS: The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS: This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION: In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION: NCT04893317.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Criocirugía , Taquicardia Ventricular , Anciano , Humanos , Persona de Mediana Edad , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico , Cardiomiopatías/cirugía , Ablación por Catéter/efectos adversos , Cicatriz/complicaciones , Criocirugía/efectos adversos , Estudios Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Temperatura , Resultado del Tratamiento
9.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38584468

RESUMEN

AIMS: Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. METHODS AND RESULTS: After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 s per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 ± 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 ± 21.6, 10.0 ± 6.0, 19.1 ± 9.3, and 5.7 ± 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort. CONCLUSION: Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.


Asunto(s)
Fibrilación Atrial , Catéteres Cardíacos , Ablación por Catéter , Venas Pulmonares , Recurrencia , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Masculino , Femenino , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Diseño de Equipo , Técnicas Electrofisiológicas Cardíacas , Factores de Tiempo , Frecuencia Cardíaca , Potenciales de Acción
10.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38305503

RESUMEN

AIMS: When it occurs, pulmonary vein (PV) stenosis after atrial fibrillation (AF) ablation is associated with significant morbidity. Even mild-to-moderate PV narrowing may have long-term implications. Unlike thermal ablation energies, such as radiofrequency (RF) or cryothermy, pulsed field ablation (PFA) is a non-thermal modality associated with less fibrotic proliferation. Herein, we compared the effects of PFA vs. thermal ablation on PV narrowing after AF ablation. METHODS AND RESULTS: ADVENT was a multi-centre, randomized, single-blind study comparing PFA (pentaspline catheter) with thermal ablation-force-sensing RF or cryoballoon (CB)-to treat drug-refractory paroxysmal AF. Pulmonary vein diameter and aggregate cross-sectional area were obtained by baseline and 3-month imaging. The pre-specified, formally tested, secondary safety endpoint compared a measure of PV narrowing between PFA vs. thermal groups, with superiority defined by posterior probability > 0.975. Among subjects randomized to PFA (n = 305) or thermal ablation (n = 302), 259 PFA and 255 thermal ablation (137 RF and 118 CB) subjects had complete baseline and 3-month PV imaging. No subject had significant (≥70%) PV stenosis. Change in aggregate PV cross-sectional area was less with PFA (-0.9%) than thermal ablation (-12%, posterior probability > 0.999)-primarily driven by the RF sub-cohort (-19.5%) vs. CB sub-cohort (-3.3%). Almost half of all PFA PV diameters did not decrease, but the majority (80%) of RF PVs decreased, regardless of PV anatomic location. CONCLUSION: In this first randomized comparison of PFA vs. thermal ablation, PFA resulted in less PV narrowing-thereby underscoring the qualitatively differential and favourable impact of PFA on PV tissue.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Estenosis de Vena Pulmonar , Humanos , Venas Pulmonares/cirugía , Constricción Patológica/complicaciones , Constricción Patológica/cirugía , Método Simple Ciego , Resultado del Tratamiento , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Estenosis de Vena Pulmonar/diagnóstico por imagen , Estenosis de Vena Pulmonar/etiología
11.
Circulation ; 146(24): 1808-1819, 2022 12 13.
Artículo en Inglés | MEDLINE | ID: mdl-36134574

RESUMEN

BACKGROUND: Pulsed field ablation (PFA) has a unique safety profile when used to treat atrial fibrillation, largely related to its preferentiality for myocardial tissue ablation, in particular, esophageal sparing. A pentaspline catheter was the first such PFA system studied clinically for atrial fibrillation ablation; in these initial regulatory trials, the catheter was used for pulmonary vein isolation and left atrial posterior wall ablation. Since its regulatory approval in Europe, in clinical practice, physicians have ablated beyond pulmonary vein isolation and left atrial posterior wall ablation to expanded lesion sets in closer proximity to coronary arteries. This is an unstudied important issue because preclinical and clinical data have raised the potential for coronary arterial spasm. Herein, we studied the vasospastic potential of PFA lesion sets, both remote from and adjacent to coronary arteries. METHODS: During routine atrial fibrillation ablation using the pentaspline PFA catheter, coronary angiography was performed before, during, and after pulsed field applications. The lesion sets studied included: (1) those remote from the coronary arteries such as pulmonary vein isolation (n=25 patients) and left atrial posterior wall ablation (n=5), and (2) ablation of the cavotricuspid isthmus (n=20) that is situated adjacent to the right coronary artery. RESULTS: During pulmonary vein isolation and left atrial posterior wall ablation, coronary spasm did not occur, but cavotricuspid isthmus ablation provoked severe subtotal vasospasm in 5 of 5 (100%) consecutive patients, and this was relieved by intracoronary nitroglycerin in 5.5±3.5 minutes. ST-segment elevation was not observed. However, no patient (0%, P=0.004) had severe spasm if first administered parenteral nitroglycerin, either intracoronary (n=5) or intravenous (n=10), before treatment. CONCLUSIONS: Coronary vasospasm was not provoked during PFA at locations remote from coronary arteries, but when the energy is delivered adjacent to a coronary artery, PFA routinely provokes subclinical vasospasm. This phenomenon is attenuated by nitroglycerin, administered either post hoc to treat spasm or as prophylaxis.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Ablación por Catéter/efectos adversos , Atrios Cardíacos , Nitroglicerina/uso terapéutico , Resultado del Tratamiento
12.
Stroke ; 54(3): e75-e85, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36848427

RESUMEN

Atrial fibrillation (AF) is one of the strongest risk factors for ischemic stroke, which is a leading cause of disability and death. Given the aging population, increasing prevalence of AF risk factors, and improved survival in those with cardiovascular disease, the number of individuals affected by AF will continue increasing over time. While multiple proven stroke prevention therapies exist, important questions remain about the optimal approach to stroke prevention at the population and individual patient levels. Our report summarizes the National Heart, Lung, and Blood Institute virtual workshop focused on identifying key research opportunities related to stroke prevention in AF. The workshop reviewed major knowledge gaps and identified targeted research opportunities to advance stroke prevention in AF in the following areas: (1) improving risk stratification tools for stroke and intracranial hemorrhage; (2) addressing challenges with oral anticoagulants; and (3) delineating the optimal roles of percutaneous left atrial appendage occlusion and surgical left atrial appendage closure/excision. This report aims to promote innovative, impactful research that will lead to more personalized, effective use of stroke prevention strategies in people with AF.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Estados Unidos/epidemiología , Humanos , Anciano , Fibrilación Atrial/complicaciones , National Heart, Lung, and Blood Institute (U.S.) , Corazón , Academias e Institutos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control
13.
Am Heart J ; 264: 123-132, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37279840

RESUMEN

BACKGROUND: Percutaneous left atrial appendage (LAA) closure (LAAC) was developed as a nonpharmacologic alternative to oral anticoagulants (OACs) in patients with atrial fibrillation (AF) who are at an increased risk for stroke or systemic embolism. The Watchman device permanently seals off the LAA to prevent thrombi from escaping into the circulation. Previous randomized trials have established the safety and efficacy of LAAC compared to warfarin. However, direct OACs (DOACs) have become the preferred pharmacologic strategy for stroke prevention in patients with AF, and there is limited data comparing Watchman FLX to DOACs in a broad AF patient population. CHAMPION-AF is designed to prospectively determine whether LAAC with Watchman FLX is a reasonable first-line alternative to DOACs in patients with AF who are indicated for OAC therapy. STUDY DESIGN: A total of 3,000 patients with a CHA2DS2-VASc score ≥2 (men) or ≥3 (women) were randomized to Watchman FLX or DOAC in a 1:1 allocation at 142 global clinical sites. Patients in the device arm were to be treated with DOAC and aspirin, DOAC alone, or DAPT for at least 3 months postimplant followed by aspirin or P2Y12 inhibitor for 1-year. Control patients were required to take an approved DOAC for the duration of the trial. Clinical follow-up visits are scheduled at 3- and 12-months, and then annually through 5 years; LAA imaging is required at 4 months in the device group. Two primary end points will be evaluated at 3 years: (1) composite of stroke (ischemic/hemorrhagic), cardiovascular death, and systemic embolism compared for noninferiority, and (2) nonprocedural bleeding (International Society on Thrombosis and Haemostasis [ISTH] major and clinically relevant nonmajor bleeding) tested for superiority in the device arm against DOACs. The third primary noninferiority end point is the composite of ischemic stroke and systemic embolism at 5 years. Secondary end points include 3- and 5-year rates of (1) ISTH-defined major bleeding and (2) the composite of cardiovascular death, all stroke, systemic embolism, and nonprocedural ISTH bleeding. CONCLUSIONS: This study will prospectively evaluate whether LAAC with the Watchman FLX device is a reasonable alternative to DOACs in patients with AF. CLINICAL TRIAL REGISTRATION: NCT04394546.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Embolia , Accidente Cerebrovascular , Masculino , Humanos , Femenino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Resultado del Tratamiento , Estudios de Seguimiento , Apéndice Atrial/cirugía , Anticoagulantes/uso terapéutico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/epidemiología , Hemorragia/inducido químicamente , Hemorragia/complicaciones , Aspirina/uso terapéutico , Embolia/prevención & control
14.
J Cardiovasc Electrophysiol ; 34(11): 2195-2202, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37712346

RESUMEN

BACKGROUND: Pulsed-field ablation (PFA) has emerged as a nonthermal energy source for cardiac ablation, with potential safety advantages over radiofrequency ablation (RFA) and cryoballoon ablation. OBJECTIVE: To report the preclinical results of a novel hexaspline PFA catheter for pulmonary vein isolation (PVI), and to verify the influence of PFA on esophagus by comparing with RFA. METHODS: This study included a total of 15 canines for the efficacy and safety study and four swine for the esophageal safety study. The 15 canines were divided into an acute cohort (n = 3), a 30-day follow-up cohort (n = 5) and a 90-day follow-up cohort (n = 7), PVI was performed with the novel hexaspline PFA ablation catheter. In the esophageal safety study, four swine were divided into PFA cohort (n = 2) and RFA cohort (n = 2), esophageal injury swine model was adopted, the esophagus was intubated with an esophageal balloon retractor, under fluoroscopy, the DV8 device was inflated with a mixture of saline and contrast and rotated to displace the esophagus rightward and anteriorly toward the ablation catheter in the inferior vena cava (IVC) and right inferior pulmonary vein (PV). Nine PFA applications were delivered at four locations on IVC and two locations on the right inferior PV in the PFA cohort, six RFA applications were delivered at each location in the RFA group. Histopathological analysis of all PVs, esophagus, IVC, and the adjacent lungs was performed. RESULTS: Acute PV isolation was achieved in all 15 canines (100%), with energy delivery times of less than 3 min/animal. In the 30 and 90 days group, the overall success rates were 88.9% and 88.5% per PVs, respectively. Two right superior pulmonary veins (RSPVs) in the 30-day group, two RSPVs and one left superior PV in the 90-day group with recovered potentials. At follow-up, gross pathological examination revealed the lesions around the PVs were continuous and transmural. Masson's trichrome staining revealed the myocardial cells in the PVs became fibrotic, but small arteries and nervous tissue were preserved. Results of swine esophageal injury model revealed the esophageal luminal surface was smooth and without evidence for esophageal injury in the PFA group, whereas obvious ulceration was detected on the esophagus tunica mucosa in the RFA group. CONCLUSION: In the chronic canine study, PFA-based PVI were safe and effective with demonstrable sparing of nerves and venous tissue. Compared with RFA, there was also good evidence for safety of PFA, avoiding PV stenosis and esophageal injury. This preclinical study provided the scientific basis for the first-in-human endocardial PFA studies.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Ablación por Radiofrecuencia , Humanos , Porcinos , Animales , Perros , Venas Pulmonares/cirugía , Venas Pulmonares/patología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/patología , Ablación por Catéter/métodos , Catéteres , Resultado del Tratamiento
15.
J Cardiovasc Electrophysiol ; 34(2): 315-324, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36511472

RESUMEN

INTRODUCTION: Visually-guided laser balloon ablation (VGLA) currently requires careful manual rotation of the laser to create overlapping lesions. A novel semi-automated VGLA may reduce ablation times and lesion gaps. We aimed to compare semi-automated (SA) VGLA to that of manual (MN) VGLA. METHODS: Acute: Nine swine underwent right superior pulmonary vein isolation (PVI) using either SA (n = 3, 13-18 W), MN (n = 3, 8.5-12 W), or radiofrequency (RF, n = 3, 25-40 W) and were killed acutely. Chronic: 16 swine, underwent PVI using either SA (n = 8, 15 W) or MN (n = 8, 10 W), and were survived for 1 month before being killed. All hearts were then submitted for pathological evaluation. RESULTS: Acute: PVI was successful in all 9/9 swine with lesion counts significantly lower in the SA arm (5.3 ± 5.9, 33.7 ± 10.0, and 28.0 ± 4.4 in SA, MN, and RF arms; p = .007 for SA and MN). At necropsy, circumferentiality and transmurality were 98% and 94% in SA, 98% and 80% in MN, and 100% and 100% in RF arms. A single steam pop was noted on sectioning in the SA arm swine and occurred in the high dose (18 W) strategy. Chronic: PVI was acutely successful in 16/16 swine with no difference in PVI durability rates (62.5% vs. 75.0%), lesion transmurality (95.8 ± 17.4% vs.91.9 ± 25.9%), and circumferentiality (95.8 ± 6.6% vs. 94.8 ± 6.3%) between SA and MN arms. Catheter use time and lesion counts were lower in the SA arm compared to the MN arm (11.5 ± 12.7 vs. 21.8 ± 3.8 min, p = .046 and 4.8 ± 3.83 vs. 35.4 ± 4.4, p < .001). CONCLUSION: Motor-assisted semi-automated laser balloon ablation can improve upon procedural efficiency by reducing ablation time.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Terapia por Láser , Venas Pulmonares , Porcinos , Animales , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Terapia por Láser/efectos adversos
16.
J Cardiovasc Electrophysiol ; 34(5): 1277-1285, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36950852

RESUMEN

INTRODUCTION: Multiple randomized controlled trials have demonstrated sodium-glucose cotransporter-2 inhibitors (SGLT2i) decrease the composite endpoint of cardiovascular death or heart failure hospitalizations in all heart failure patients. It is uncertain whether SGLT2i impacts the risk of sudden cardiac death in patients with heart failure. METHODS: A comprehensive search was performed to identify relevant data published before August 28, 2022. Trials were included if: (1) all patients had clinical heart failure (2) SGLT2i and placebo were compared (3) all patients received conventional medical therapy and (4) reported outcomes of interest (sudden cardiac death [SCD], ventricular arrhythmias, atrial arrhythmias). RESULTS: SCD was reported in seven of the eleven trials meeting selection criteria: 10 796 patients received SGLT2i and 10 796 received placebo. SGLT2i therapy was associated with a significant reduction in the risk of SCD (risk ratios [RR]: 0.68; 95% confidence intervals [CI]: 0.48-0.95; p = .03; I2 = 0%). Absent dedicated rhythm monitoring, there were no significant differences in the incidence of sustained ventricular arrhythmias not associated with SCD (RR: 1.03; 95% CI: 0.83-1.29; p = .77; I2 = 0%) or atrial arrhythmias (RR: 0.91; 95% CI: 0.77-1.09; p = .31; I2 = 29%) between patients receiving an SGLT2i versus placebo. CONCLUSION: SGLT2i therapy is associated with a reduced risk of SCD in patients with heart failure receiving contemporary medical therapy. Prospective trials are needed to determine the long-term impact of SGLT2i therapy on atrial and ventricular arrhythmias.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Inhibidores del Cotransportador de Sodio-Glucosa 2 , Humanos , Fibrilación Atrial/complicaciones , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/epidemiología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/complicaciones , Estudios Prospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto , Inhibidores del Cotransportador de Sodio-Glucosa 2/efectos adversos
17.
J Cardiovasc Electrophysiol ; 34(9): 1885-1895, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37529864

RESUMEN

INTRODUCTION: Observational studies have shown low bleeding rates in patients with atrial fibrillation (AF) treated by left atrial appendage closure (LAAC); however, data from randomized studies are lacking. This study compared bleeding events among patients with AF treated by LAAC and nonvitamin K anticoagulants (NOAC). METHODS: The Prague-17 trial was a prospective, multicenter, randomized trial that compared LAAC to NOAC in high-risk AF patients. The primary endpoint was a composite of a cardioembolic event, cardiovascular death, and major and clinically relevant nonmajor bleeding (CRNMB) defined according to the International Society on Thrombosis and Hemostasis (ISTH). RESULTS: The trial enrolled 402 patients (201 per arm), and the median follow-up was 3.5 (IQR 2.6-4.2) years. Bleeding occurred in 24 patients (29 events) and 32 patients (40 events) in the LAAC and NOAC groups, respectively. Six of the LAAC bleeding events were procedure/device-related. In the primary intention-to-treat analysis, LAAC was associated with similar rates of ISTH major or CRNMB (sHR 0.75, 95% CI 0.44-1.27, p = 0.28), but with a reduction in nonprocedural major or CRNMB (sHR 0.55, 95% CI 0.31-0.97, p = 0.039). This reduction for nonprocedural bleeding with LAAC was mainly driven by a reduced rate of CRNMB (sHR for major bleeding 0.69, 95% CI 0.34-1.39, p = .30; sHR for CRNMB 0.43, 95% CI 0.18-1.03, p = 0.059). History of bleeding was a predictor of bleeding during follow-up. Gastrointestinal bleeding was the most common bleeding site in both groups. CONCLUSION: During the 4-year follow-up, LAAC was associated with less nonprocedural bleeding. The reduction is mainly driven by a decrease in CRNMB.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Anticoagulantes/efectos adversos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Apéndice Atrial/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Hemorragia/inducido químicamente , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico
18.
J Cardiovasc Electrophysiol ; 34(2): 279-290, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36352771

RESUMEN

INTRODUCTION: Use of a novel magnetic sensor enabled optical contact force ablation catheter has been established to be safe and effective for treatment of symptomatic drug-refractory paroxysmal atrial fibrillation (AF) but has yet to be demonstrated in the persistent AF (PersAF) population. METHODS: PERSIST-END was a multicenter, prospective, nonrandomized, investigational study designed to demonstrate the safety and effectiveness of TactiCath™ Ablation Catheter, Sensor Enabled™(SE) (TactiCath SE) for use in the treatment of subjects with documented PersAF refractory or intolerant to at least one Class I/III AAD. The ablation strategy included pulmonary vein isolation and additional targets at physician discretion. Follow-up through 15-months, including a 3-month blanking period and 3-month therapy consolidation period, was performed with cardiac event and Holter monitoring. Primary safety, primary effectiveness, clinical success, and quality of life (QOL) endpoints were analyzed. RESULTS: Of 224 subjects enrolled at 21 investigational sites in the United States and Australia, 223 underwent ablation with the investigational catheter. The primary safety event rate was 3.1% (seven events in seven subjects). The Kaplan-Meier estimate of freedom from AF/atrial flutter/atrial tachycardia recurrence at 15-months was 61.6% and clinical success at 15 months was 89.8%. Subject QOL significantly improved following ablation as assessed via AFEQT (31.6 point increase, p < .0001) and EQ-5D-5L (10.7 point increase, p < .0001) and was met with a 53% reduction in all cause cardiovascular healthcare utilization. CONCLUSION: The sensor-enabled force-sensing catheter is safe and effective for the treatment of drug refractory recurrent symptomatic PersAF, reducing arrhythmia recurrence while improving QOL and healthcare utilization.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Calidad de Vida , Estudios Prospectivos , Sistema de Conducción Cardíaco , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Recurrencia
19.
J Card Fail ; 29(7): 1046-1055, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36958391

RESUMEN

BACKGROUND: Left ventricular (LV) volume reshaping reduces myocardial wall stress and may induce reverse remodeling in patients with heart failure with reduced ejection fraction. The AccuCinch Transcatheter Left Ventricular Restoration system consists of a series of anchors connected by a cable implanted along the LV base that is cinched to the basal free wall radius. We evaluated the echocardiographic and clinical outcomes following transcatheter left ventricular restoration. METHODS AND RESULTS: We analyzed 51 heart failure patients with a left ventricular ejection fraction between 20% and 40%, with no more than 2+ mitral regurgitation treated with optimal medical therapy, who subsequently underwent transcatheter left ventricular restoration. Serial echocardiograms, Kansas City Cardiomyopathy Questionnaire scores, and 6-minute walk test distances were measured at baseline through 12 months. Primary analysis end point was change in end-diastolic volume at 12 months compared with baseline. Patients (n = 51) were predominantly male (86%) with a mean age of 56.3 ± 13.1 years. Fluoroscopy showed LV free wall radius decreased by a median of 9.2 mm amounting to a 29.6% decrease in the free wall arc length. At 12 months, the LV end-diastolic volume decreased by 33.6 ± 34.8 mL (P < .01), with comparable decreases in the LV end-systolic volume. These decreases were associated with significant improvements in the overall Kansas City Cardiomyopathy Questionnaire score (16.4 ± 18.7 points; P < .01) and 6-minute hall walk test distance (45.9 ± 83.9 m; P < .01). There were no periprocedural deaths; through the 1-year follow-up, 1 patient died (day 280) and 1 patient received a left ventricular assist device (day 13). CONCLUSIONS: In patients with heart failure with reduced ejection fraction without significant mitral regurgitation receiving optimal medical therapy, the AccuCinch System resulted in decreases of LV volume, as well as improved quality of life and exercise endurance. A randomized trial is ongoing (NCT04331769).


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Disfunción Ventricular Izquierda , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Calidad de Vida , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Remodelación Ventricular
20.
Europace ; 25(4): 1369-1378, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36794699

RESUMEN

AIMS: Single-shot pulmonary vein isolation can improve procedural efficiency. To assess the capability of a novel, expandable lattice-shaped catheter to rapidly isolate thoracic veins using pulsed field ablation (PFA) in healthy swine. METHODS AND RESULTS: The study catheter (SpherePVI; Affera Inc) was used to isolate thoracic veins in two cohorts of swine survived for 1 and 5 weeks. In Experiment 1, an initial dose (PULSE2) was used to isolate the superior vena cava (SVC) and the right superior pulmonary vein (RSPV) in six swine and the SVC only in two swine. In Experiment 2, a final dose (PULSE3) was used for SVC, RSPV, and left superior pulmonary vein (LSPV) in five swine. Baseline and follow-up maps, ostial diameters, and phrenic nerve were assessed. Pulsed field ablation was delivered atop the oesophagus in three swine. All tissues were submitted for pathology. In Experiment 1, all 14/14 veins were isolated acutely with durable isolation demonstrated in 6/6 RSPVs and 6/8 SVC. Both reconnections occurred when only one application/vein was used. Fifty-two and 32 sections from the RSPVs and SVC revealed transmural lesions in 100% with a mean depth of 4.0 ± 2.0 mm. In Experiment 2, 15/15 veins were isolated acutely with 14/15 veins (5/5 SVC, 5/5 RSPV, and 4/5 LSPV) durably isolated. Right superior pulmonary vein (31) and SVC (34) sections had 100% transmural, circumferential ablation with minimal inflammation. Viable vessels and nerves were noted without evidence of venous stenosis, phrenic palsy, or oesophageal injury. CONCLUSION: This novel expandable lattice PFA catheter can achieve durable isolation with transmurality and safety.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Porcinos , Animales , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/patología , Venas Pulmonares/cirugía , Venas Pulmonares/patología , Vena Cava Superior/cirugía , Estudios de Factibilidad , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Catéteres , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA