Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 183
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39323300

RESUMEN

BACKGROUND: Coronary artery dissections are caused by a tear in the vessel endothelium, resulting in blood extravasation into the subintimal space, with subsequent intramural hematoma (IMH). One potential technique to deal with this complication is the use of cutting balloons, however, a significant number of cases experienced distal propagation of the hematoma. We describe a novel technique that enhances the possibility of creating intimal tears between the false and true lumen, aiding in hematoma drainage and restoring distal coronary flow. METHODS: We conducted a retrospective analysis of seven consecutive patients who underwent percutaneous coronary intervention complicated by flow-limiting intramural hematomas. All patients were treated using the "Cuttering Technique," based on the operators' preference. Procedural success was defined as achieving a distal thrombolysis in myocardial infarction 3 (TIMI 3) flow. RESULTS: In five out of seven patients treated with "Cuttering Technique" we observed a complete restoration of TIMI 3 flow into the dissected segment. CONCLUSIONS: Our cases show the effectiveness of the "Cuttering Technique" as a viable approach for managing IMHs. This technique enhances the possibility of creating intimal tears between the false and true lumens, aiding in hematoma drainage and restoring distal coronary flow.

2.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37957842

RESUMEN

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Dilatación , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Diseño de Prótesis
3.
Cardiovasc Diabetol ; 22(1): 28, 2023 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-36747244

RESUMEN

BACKGROUND: Despite paucity of data, it is common practice to discontinue metformin before invasive coronary angiography due to an alleged risk of Metformin-Associated Lactic Acidosis (M-ALA). We aimed at assessing the safety of metformin continuation in diabetic patients undergoing coronary angiography in terms of significant increase in lactate levels. METHODS: In this open-label, prospective, multicentre, single-arm trial, all diabetic patients undergoing coronary angiography with or without percutaneous coronary intervention at 3 European centers were screened for enrolment. The primary endpoint was the increase in lactate levels from preprocedural levels at 72-h after the procedure. Secondary endpoints included contrast associated-acute kidney injury (CA-AKI), M-ALA, and all-cause mortality. RESULTS: 142 diabetic patients on metformin therapy were included. Median preprocedural lactate level was 1.8 mmol/l [interquartile range (IQR) 1.3-2.3]. Lactate levels at 72 h after coronary angiography were 1.7 mmol/l (IQR 1.3-2.3), with no significant differences as compared to preprocedural levels (p = 0.91; median difference = 0; IQR - 0.5 to 0.4 mmol/l). One patient had 72-h levels ≥ 5 mmol/l (5.3 mmol/l), but no cases of M-ALA were reported. CA-AKI occurred in 9 patients (6.1%) and median serum creatinine and estimated glomerular filtration rate remained similar throughout the periprocedural period. At a median follow-up of 90 days (43-150), no patients required hemodialysis and 2 patients died due to non-cardiac causes. CONCLUSIONS: In diabetic patients undergoing invasive coronary angiography, metformin continuation throughout the periprocedural period does not increase lactate levels and was not associated with any decline in renal function. TRIAL REGISTRATION: The study was registered at Clinicaltrials.gov (NCT04766008).


Asunto(s)
Acidosis Láctica , Lesión Renal Aguda , Diabetes Mellitus , Metformina , Humanos , Acidosis Láctica/inducido químicamente , Acidosis Láctica/diagnóstico , Lesión Renal Aguda/inducido químicamente , Lesión Renal Aguda/diagnóstico , Angiografía Coronaria/efectos adversos , Diabetes Mellitus/inducido químicamente , Hipoglucemiantes/efectos adversos , Lactatos , Metformina/efectos adversos , Estudios Prospectivos
4.
Catheter Cardiovasc Interv ; 101(5): 911-917, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36856010

RESUMEN

BACKGROUND: Chronic total occlusion (CTO) revascularization is a major source of radiation for both patients and physicians. Therefore, efforts to minimize radiation during CTO percutaneous coronary intervention (PCI) are highly encouraged. AIMS: To evaluate the impact of an Ultra Low fluoroscopic Dose Protocol (ULDP), based on 3.75 frames per second for the fluoroscopy and 7.5 frames per second for the cine acquisition, during CTO PCI. METHODS: One hundred fifty consecutive patients who underwent CTO PCI were retrospectively enrolled. Eighty-five underwent standard dose protocol (SDP) and 65 ULDP. Radiation exposure and acute clinical outcomes were compared between groups. Results were stratified according to lesion complexity. RESULTS: Patients undergoing ULDP, as compared to those undergoing SDP, showed a significant reduction of kerma area product, both for simple lesions (6861.0 vs. 13236.0 mGy × cm2 ; p = 0.014) and complex lesions (CL) (8865.0 vs. 16618.0 mGy × cm2 ; p < 0.001). Similarly, Air Kerma (AK) was lower when ULDP was used (1222.5 vs. 2015.0 cGy in SL, p = 0.134; 1499.0 vs. 2794.0 cGy in CL, p < 0.001). No significant differences were reported regarding procedural success and in-hospital major adverse cardiovascular events between groups. Notably, there was not any crossover from ULDO to SDP due to poor quality images. Interestingly, fluoroscopy time, procedural time and contrast volume was significantly lower in patients undergoing ULDP only for CLs. CONCLUSIONS: ULDP significantly reduces radiation exposure in the setting of high complexity procedures such as CTO PCI. This reduction seemed to be greater with increased procedural complexity and did not impact acute success or adverse clinical events.


Asunto(s)
Oclusión Coronaria , Fluoroscopía , Intervención Coronaria Percutánea , Humanos , Enfermedad Crónica , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/métodos , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Oclusión Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
5.
Catheter Cardiovasc Interv ; 101(4): 798-805, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36841945

RESUMEN

OBJECTIVES: The objective of this study is to investigate the use of cutting balloon (CB) inflated at high pressure compared with noncompliant balloon (NCB) for the treatment of calcified coronary lesions. BACKGROUND: No data are available regarding the safety and efficacy of CB inflated at high pressure in coronary artery calcifications. METHODS: Patients with calcified lesions (more than 100° of calcium demonstrated at baseline intravascular ultrasound) were randomized. Primary endpoint of the study was the final minimal stent area (MSA) and stent symmetry in the calcific segment. Secondary endpoints included rate of device failure and the 1-year rate of target lesion revascularization, target vessel revascularization, and major adverse cardiovascular events. RESULTS: From September 2019 to June 2021, a total of 100 patients were included and randomized; 13 patients were excluded for major protocol deviations. Lesions were complex (type B2/C n = 61 [71.2%]) with a mean arch of calcium of 266 ± 84°, a calcium length of 12 ± 6.6 mm. CB was inflated at comparable atmospheres when compared with NCB (18.3 ± 5 vs. 19 ± 4.5, p = 0.46). In the per-protocol population, the final MSA at the level of the calcium site was significantly higher in the CB group (8.1 ± 2 vs. 7.3 ± 2.1, p = 0.035) with a higher eccentricity index achieved in the CB group (0.84 ± 0.07 vs. 0.8 ± 0.08, p = 0.013). Three device failure occurred in the CB group. One-year follow-up outcomes were comparable. CONCLUSIONS: Treatment of calcified lesions with high-pressure CB has a good safety profile and is associated with a larger MSA and higher eccentricity of the stent at the level of the calcium site compared with NCB.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Humanos , Angiografía Coronaria , Calcio , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/terapia , Stents
6.
Catheter Cardiovasc Interv ; 102(5): 931-943, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37668097

RESUMEN

BACKGROUND: Evidence of clinical impact of PPM after TAVI is conflicting and might vary according to the type of valve implanted. AIMS: To assess the clinical impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) with balloon-expandable (BEV) and self-expandable valves (SEV) in patients with small annuli. METHODS: TAVI-SMALL 2 enrolled 628 patients in an international retrospective registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 ) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Analyses were performed comparing patients with less than moderate (n = 452), moderate (n = 138), and severe PPM (n = 38). Primary endpoint was incidence of all-cause mortality. Predictors of all-cause mortality and PPM were investigated. RESULTS: At a median follow-up of 380 days (interquartile range: 210-709 days), patients with severe PPM, but not moderate PPM, had an increased risk of all-cause mortality when compared with less than moderate PPM (log-rank p = 0.046). Severe PPM predicted all-cause mortality in patients with BEV (hazard ratio [HR]: 5.20, 95% confidence interval [CI]: 1.27-21.2) and intra-annular valves (IAVs, HR: 4.23, 95% CI: 1.28-14.02), and it did so with borderline significance in the overall population (HR: 2.89, 95% CI: 0.95-8.79). Supra-annular valve (SAV) implantation was the only predictor of severe PPM (odds ratio: 0.33, 95% CI: 0.13-0.83). CONCLUSIONS: Patients with small aortic annuli and severe PPM after TAVI have an increased risk of all-cause mortality at early term follow-up, especially after IAV or BEV implantation. TAVI with SAV protected from severe PPM.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Estudios Retrospectivos , Diseño de Prótesis , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
7.
Catheter Cardiovasc Interv ; 102(6): 1048-1056, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37933728

RESUMEN

BACKGROUND: Percutaneous treatment for ostial left circumflex artery (LCx) lesions is known to be associated with suboptimal results. AIMS: The present study aims to assess the procedural and long-term clinical outcomes of percutaneous coronary intervention (PCI) for de novo ostial LCx lesions overall and according to the coronary revascularization strategy. METHODS: Consecutive patients undergoing PCI with second generation drug eluting stents or drug coated balloons for de novo ostial LCx lesions in three high-volume Italian centers between 2012 and 2021 were retrospectively evaluated. The primary endpoint was target-vessel revascularization (TVR) at 2 years. Secondary endpoints included major adverse cardiovascular and cerebrovascular events (MACCE), target lesion revascularization, myocardial infarction, stroke, all-cause death, and repeat revascularization. RESULTS: A total of 366 patients were included in the analysis with a median follow-up of 901 (IQR: 450-1728) days. 79.5% of the patients were male, 33.6% were diabetic, 49.7% had a previous PCI, and 23.1% a prior surgical revascularization. Very ostial LCx stenting was performed in 34.1%, crossover from left main to LCx in 17.3%, and a two-stent strategy in 48.6% of cases, respectively. In the overall population, the incidence of TVR at 2 years was 19.0% while MACCE rate was 25.7%. No major differences in clinical outcomes were found according to the stenting strategy. Use of intracoronary imaging was associated with fewer MACCE (HR: 0.47, 95% CI: 0.25-1.13, p = 0.01), while the diameter of the stent implanted in the ostial LCx was associated with less TVR (HR: 0.43, 95% CI: 0.25-0.75, p = 0.002). CONCLUSIONS: Percutaneous revascularization of the ostial LCx is associated with a high rate of TVR, regardless of the stenting strategy. Intracoronary imaging and proper stent sizing may reduce the failure rates.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Masculino , Femenino , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Angiografía Coronaria/métodos
8.
Eur Heart J Suppl ; 25(Suppl C): C79-C83, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37125288

RESUMEN

True coronary bifurcation lesions (CBL) represent a challenging scenario for percutaneous coronary interventions (PCI), and are associated with a higher risk of target lesion failure (TLF), particularly when two stents are implanted. A hybrid strategy combining a drug-eluting stent (DES) in the main branch, and a drug-coated balloon in the side branch may improve outcomes by reducing the total stent length while maintaining an effective anti-prolipherative action. In this sub-study of the HYPER trial, 50 patients with true CBL were treated with a hybrid strategy: procedural success was 96%, one case of peri-procedural myocardial infarction and one case of TLF (in a DES-treated segment) at 1 year were reported. This study suggests that such a hybrid strategy may be a safe and effective option for true CBL PCI, and warrants additional investigations to compare outcomes with standard of care strategies.

9.
Rev Cardiovasc Med ; 23(2): 76, 2022 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-35229567

RESUMEN

Tricuspid regurgitation (TR) has a considerable prevalence in the overall population, that further increases in selected categories of patients. Three morphologic types of TR prevail, namely primary, secondary and atrial TR, mostly, but not always, occurring in different subsets of patients. Recent evidences demonstrate a negative impact of TR on outcomes, irrespective of etiology and even when less than severe in grading. Unfortunately, current surgical standards are void of strong prospective evidence of positive impact on clinical outcomes. While on one hand recent advances in diagnosis and risk stratification of patients with TR are shedding light onto the population that may benefit from intervention and its appropriate timing, on the other hand the arrival on stage of percutaneous treatment options is widening even more the therapeutic options for such population. In this review we will address and discuss the available evidence on the prognostic impact of TR in different clinical contexts encountered in practice.


Asunto(s)
Insuficiencia de la Válvula Tricúspide , Humanos , Pronóstico , Estudios Prospectivos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/terapia
10.
Rev Cardiovasc Med ; 23(7): 220, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39076922

RESUMEN

Tricuspid regurgitation (TR) negatively affects patient outcomes. Surgical tricuspid valve repair/replacement carries a high operative risk and is not a viable option for many high-risk patients. Percutaneous approaches provide an attractive alternative solution for such patients since they represent a valid alternative to open heart surgery without the significant risks carried by surgery. A number of percutaneous devices are currently under clinical development. This review will discuss about the latest development in the field of percutaneous tricuspid valve repair with possible future developments.

11.
Catheter Cardiovasc Interv ; 99(6): 1766-1777, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35312151

RESUMEN

INTRODUCTION: Device entrapment is a life-threatening complication during percutaneous coronary intervention (PCI). However, the success for its management is predominantly based on operator experience with limited available guidance in the published literature. METHODS: A systematic review was performed on December 2021; we searched PubMed for articles on device entrapment during PCI. In addition, backward snowballing (i.e., review of references from identified articles and pertinent reviews) was employed. RESULTS: A total of 4209 articles were retrieved, of which 150 studies were included in the synthesis of the data. A methodical algorithmic approach to prevention and management of device entrapment can help to optimize outcomes. The recommended sequence of steps are as follows: (a) pulling, (b) trapping, (c) snaring, (d) plaque modification, (e) telescoping, and (f) surgery. CONCLUSIONS: In-depth knowledge of the techniques and necessary tools can help optimize the likelihood of successful equipment retrieval and minimization of complications.


Asunto(s)
Intervención Coronaria Percutánea , Placa Aterosclerótica , Humanos , Resultado del Tratamiento
12.
Catheter Cardiovasc Interv ; 100(5): 903-909, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36040688

RESUMEN

OBJECTIVES: To report the experience of a high-volume center with balloon-expandable (BE) stents implantation to manage vascular complications after transcatheter aortic valve replacement (TAVR). BACKGROUND: Despite increased operator experience and better devices, vascular complications after TAVR are still a major issue and covered stent implantation is often required. METHODS: We retrospectively collected baseline and procedural data about 78 consecutive patients who underwent BE stent implantation to manage a vascular complication after transfemoral TAVR. Primary endpoints were technical success, incidence of new-onset claudication and need for vascular interventions during long-term follow-up. Secondary endpoints included length of hospitalization, in-hospital and 30-day mortality, and major postoperative complications. RESULTS: BE stents implantation to manage vascular complications after TAVR was successfully performed in 96.2% of the cases, with bailout surgery required in two cases. One patient suffered in-hospital death. Predischarge Doppler Ultrasound revealed no cases of in-stent occlusion or fracture. At a median follow-up of 429 days (interquartile range, 89-994 days), no cases of symptomatic leg ischemia were reported and only one patient experienced new-onset claudication. CONCLUSIONS: Our experience showed good periprocedural and long-term results of BE covered stent implantation to manage vascular complication after TAVR. Their great radial outward force may guarantee effective hemostasis without necessarily being associated with stent deformation/fracture resulting in restenosis or further interventions. More research is needed to define the role of BE covered stents in this setting.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Enfermedades Vasculares , Humanos , Estudios de Seguimiento , Estudios Retrospectivos , Mortalidad Hospitalaria , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Resultado del Tratamiento , Stents , Enfermedades Vasculares/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
13.
Catheter Cardiovasc Interv ; 100(4): 620-627, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35842775

RESUMEN

OBJECTIVES: To assess feasibility and safety of second-generation left atrial appendage closure (LAAC) Ultraseal device in patients with nonvalvular atrial fibrillation (NVAF). BACKGROUND: LAAC with first-generation Ultraseal device (Cardia, Eagan, Minnesota) has been shown to be a feasible therapeutic option in patients with NVAF. However, there is a paucity of data regarding the novel second-generation Ultraseal device. METHODS: All patients with NVAF undergoing second-generation Ultraseal device implantation between February 2018 and September 2020 were included in a multicenter international registry. Periprocedural and post-discharge events were collected through 6-month follow-up. Co-primary efficacy endpoints were device success and technical success while primary safety endpoint was in-hospital major adverse event (MAE) occurrence. RESULTS: A total of 52 patients were included: mean age 75 ± 8, 30.8% women, mean HAS-BLED 3 ± 1. The device was successfully implanted in all patients. Technical success was achieved in 50 patients (96.1%). In-hospital MAEs occurred in three patients (5.8%). The incidence of 6-month all-cause death and major bleeding was 11.6% and 2.1%, respectively. No strokes, transient ischemic attacks, systemic embolisms, or device embolization were reported after discharge. CONCLUSIONS: Second-generation Ultraseal device implantation was associated with high success rates and a low incidence of peri-procedural complications. Larger studies with longer follow-up are warranted to further evaluate the safety and the efficacy of this device, especially at long-term follow-up.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Cuidados Posteriores , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Femenino , Humanos , Masculino , Alta del Paciente , Sistema de Registros , Resultado del Tratamiento
14.
Lancet ; 395(10235): 1487-1495, 2020 05 09.
Artículo en Inglés | MEDLINE | ID: mdl-32386592

RESUMEN

BACKGROUND: Antiplatelet therapy is recommended among patients with established atherosclerosis. We compared monotherapy with a P2Y12 inhibitor versus aspirin for secondary prevention. METHODS: In this systematic review and meta-analysis, all randomised trials comparing P2Y12 inhibitor with aspirin monotherapy for secondary prevention in patients with cerebrovascular, coronary, or peripheral artery disease were evaluated for inclusion. On Dec 18, 2019, we searched PubMed, Embase, BioMedCentral, Google Scholar, and the Cochrane Central Register of Controlled Trials. Additionally, we reviewed references from identified articles and searched abstracts from 2017 to 2019 presented at relevant scientific meetings. Data about year of publication, inclusion and exclusion criteria, sample size, baseline patients' features including the baseline condition determining study inclusion (ie, cerebrovascular, coronary, or peripheral artery disease), P2Y12 inhibitor type and dosage, aspirin dosage, endpoint definitions, effect estimates, follow-up duration, and percentage of patients lost to follow-up were collected. Odds ratios (ORs) and 95% CIs were used as metric of choice for treatment effects with random-effects models. Co-primary endpoints were myocardial infarction and stroke. Key secondary endpoints were all-cause death and vascular death. Heterogeneity was assessed with the I2 index. This study is registered with PROSPERO (CRD42018115037). FINDINGS: A total of nine randomised trials were identified and included in this study, and 42 108 patients randomly allocated to a P2Y12 inhibitor (n=21 043) or aspirin (n=21 065) were included in our analyses. Patients who received a P2Y12 inhibitor had a borderline reduction for the risk of myocardial infarction compared with those who received aspirin (OR 0·81 [95% CI 0·66-0·99]; I2=10·9%). Risks of stroke (OR 0·93 [0·82-1·06]; I2=34·5%), all-cause death (OR 0·98 [0·89-1·08]; I2=0%), and vascular death (OR 0·97 [0·86-1·09]; I2=0%) did not differ between patients who received a P2Y12 inhibitor and those who received aspirin. Similarly, the risk of major bleeding (OR 0·90 [0·74-1·10]; I2=3·9%) did not differ between patients who received a P2Y12 inhibitor and those who received aspirin. The number needed to treat to prevent one myocardial infarction with P2Y12 inhibitor monotherapy was 244 patients. Findings were consistent regardless of the type of P2Y12 inhibitor used. INTERPRETATION: Compared with aspirin monotherapy, P2Y12 inhibitor monotherapy is associated with a risk reduction for myocardial infarction and a comparable risk of stroke in the setting of secondary prevention. The benefit of P2Y12 inhibitor monotherapy is of debatable clinical relevance, in view of the high number needed to treat to prevent a myocardial infarction and the absence of any effect on all-cause and vascular mortality. FUNDING: Italian Ministry of Education.


Asunto(s)
Aspirina/uso terapéutico , Aterosclerosis/tratamiento farmacológico , Clopidogrel/uso terapéutico , Inhibidores de Agregación Plaquetaria/uso terapéutico , Antagonistas del Receptor Purinérgico P2Y/uso terapéutico , Ticagrelor/uso terapéutico , Ticlopidina/uso terapéutico , Anciano , Aterosclerosis/complicaciones , Trastornos Cerebrovasculares/tratamiento farmacológico , Enfermedad Coronaria/tratamiento farmacológico , Femenino , Hemorragia/inducido químicamente , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/prevención & control , Enfermedad Arterial Periférica/tratamiento farmacológico , Ensayos Clínicos Controlados Aleatorios como Asunto , Medición de Riesgo , Prevención Secundaria/métodos , Accidente Cerebrovascular/prevención & control
15.
Catheter Cardiovasc Interv ; 98(2): 238-245, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32857911

RESUMEN

OBJECTIVES AND BACKGROUND: Coronary artery perforation (CAP) is a potentially life-threatening complication during percutaneous coronary interventions (PCI) and the best strategy for its management is yet to be proved. We aimed to analyze the safety, efficacy, and long-term clinical outcomes of the block and deliver (BAD) technique, as only anecdotal cases are reported in literature. METHODS: From January 2016 to January 2020, all consecutive patients treated with the BAD technique at five high-volume centers in Italy were retrospectively identified. RESULTS: 25 CAPs treated with the BAD technique were included. The most frequently perforated artery was the left anterior descending artery (32%) and spring-coil wires with a hydrophilic coating were the most common culprit wires (68%). Mean sealing time was 46.9 ± 60.1 min, with no significant differences between CTO-PCIs and non-CTO PCIs (p = .921). Acute successful sealing of the CAP was achieved in 96% of the cases. Immediate cardiac tamponade occurred in 28% of patients, four during CTO PCI and three during non-CTO PCI (p = .55). Two patients required pericardiocentesis during hospitalization, one patient developed acute kidney injury, and one patient underwent cardiac surgery due to severe mitral regurgitation. At 1-year follow-up no significant differences were observed between groups in terms of POCE (25 vs 25%, p = .628) and its individual components. CONCLUSION: The BAD technique proved to be effective for the management of CAP, showing high successful sealing rates. Rates of in-hospital events and at 1-year follow-up did not significantly differ between patients suffering CAP during CTO revascularization or during non-CTO PCI.


Asunto(s)
Oclusión Coronaria , Intervención Coronaria Percutánea , Enfermedad Crónica , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/cirugía , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Humanos , Intervención Coronaria Percutánea/efectos adversos , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
16.
Catheter Cardiovasc Interv ; 98(3): 595-604, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33586278

RESUMEN

BACKGROUND: Valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) is an emerging alternative to re-do surgery. However, the challenge of coronary access (CA) following ViV-TAVR is a potential limitation as TAVR expands to younger lower-risk populations. OBJECTIVES: Using post-implantation computed tomography (CT) scans to evaluate the geometrical relationship between coronary ostia and valve frame in patients undergoing ViV-TAVR with the ACURATE neo valve. METHODS: Post-implant CT scans of 18 out of 20 consecutive patients treated with the ACURATE neo valve were analyzed. Coronary ostia location in relation to the highest plane (HP) (highest point of the ACURATE neo or surgical valve) was determined. Ostia located below the highest plan were further subclassified according to the gap available between the transcatheter heart valve frame and ostium (transcatheter-to-coronary [TTC] distance). The impact implantation depth has on these geometrical relationships was evaluated. RESULTS: A total of 21 out of 36 coronary ostia (58%) were located below the level of the HP with the left coronary artery (36%) more likely to be affected than the right (22%). Further sub-classification of these ostia revealed a large (>6 mm), moderate (4-6 mm), and small (<4 mm) TTC distance in 57% (12/21), 38% (8/21), and in 6% (1/18) of cases, respectively. At an implantation depth <4 mm compared to >4 mm, all ostia were located below the HP with no difference in post-procedural mean gradients (14.5 mmHg ± 4.7 vs. 12.6 mmHg ± 5.8; p = .5, 95%CI 3.8-7.5). CONCLUSIONS: CA following ACURATE neo implantation for ViV-TAVR could potentially be challenging in a significant proportion of patients and specific consideration should be given to the implantation depth.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Tomografía , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
17.
Curr Cardiol Rep ; 23(10): 137, 2021 08 19.
Artículo en Inglés | MEDLINE | ID: mdl-34410511

RESUMEN

PURPOSE OF THE REVIEW: Annular-based strategies for treating tricuspid valve (TV) regurgitation do not always have satisfactory long-term outcomes. Management of failed TV annuloplasty can be challenging and requires a dedicated heart team approach. This review explores the treatment options available for failed TV annuloplasty. RECENT FINDINGS: Recent developments and novel percutaneous treatment options have emerged as promising alternatives for patients with failed TV annuloplasty. Leaflet-based interventions, valve-in-valve procedures, transcatheter tricuspid valves and new-generation trans-caval valves are all feasible options, which can assure good results whilst minimizing risks for the patient. Failure of tricuspid annuloplasty is not uncommon amongst patients treated with either a tricuspid ring or suture-based device. The complex anatomy, physiology and clinical risk profile should be carefully evaluated on an individual patient-by-patient basis in order to select the most appropriate clinical and percutaneous treatment strategy. Different transcatheter tricuspid valve repair or replacement techniques may provide an attractive alternative treatment option for managing this challenging patient cohort.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Tricúspide , Válvula Aórtica , Humanos , Válvula Mitral/cirugía , Recurrencia , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía
18.
Catheter Cardiovasc Interv ; 95(3): 411-413, 2020 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-31456357

RESUMEN

Patients presenting with cardiogenic shock and severe combined aortic and mitral regurgitation represent a major clinical challenge. Therapeutic options are limited in this setting as they are often deemed inoperable due to prohibitive risk for surgery, while mechanical circulatory support is usually contraindicated or technically challenging. Medical therapy, on the other hand, is associated with high-mortality rates. Therefore, percutaneous therapies may represent an appealing alternative. Here, we present a "one-stop-shop" totally percutaneous approach for severe aortic and mitral regurgitation in a patient with cardiogenic shock.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Choque Cardiogénico/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Prótesis Valvulares Cardíacas , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Diseño de Prótesis , Recuperación de la Función , Índice de Severidad de la Enfermedad , Choque Cardiogénico/diagnóstico , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Función Ventricular Izquierda
19.
Catheter Cardiovasc Interv ; 93(1): 120-127, 2019 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-30079565

RESUMEN

OBJECTIVE: To investigate the effect of left atrial appendage (LAA) occlusion device positioning upon periprocedural and long-term outcomes. BACKGROUND: The Amulet device is designed to cover the ostium of the LAA. Prolapse of the device into the neck of the LAA is not uncommon resulting in incomplete coverage of the ostium. The clinical consequences of this remain uncertain. METHODS: Outcomes of 87 patients with successful LAA closure were analyzed according to Amulet disc position: group A (n = 45) had complete LAA ostium coverage; group B (n = 42) had incomplete ostium coverage because of disc prolapse. Periprocedural major adverse events (MAE) (composite of all cause death, tamponade, device/air embolization, cerebrovascular events, myocardial infarction, and major bleeding not related to vascular access complications) and total device-related periprocedural adverse events (defined as MAE and pericardial effusion) were evaluated. All patients were followed up longitudinally with long-term events defined as a composite of: cardiovascular death, cerebrovascular events, systemic embolization, and major bleeding requiring transfusion or intervention. RESULTS: Median follow-up was 234 days (IQR 150-436 days). There was a trend toward more periprocedural MAE in group B (P = 0.07) with deep implantation of the Amulet device associated with significantly more periprocedural adverse events (P = 0.03). There were no differences in reposition attempts (P = 0.9) or long-term events (P = 0.57). CONCLUSIONS: Our data suggest that suboptimal device positioning may be associated with worse periprocedural outcomes but no difference in long-term clinical outcomes. The results of this relatively small cohort does not seem to be affected by repositioning attempts during the index procedure.


Asunto(s)
Apéndice Atrial/fisiopatología , Fibrilación Atrial/terapia , Cateterismo Cardíaco/instrumentación , Frecuencia Cardíaca , Anciano , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
20.
Catheter Cardiovasc Interv ; 94(4): 571-577, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-30773795

RESUMEN

OBJECTIVES: The aims of this study were to evaluate the long-term clinical outcomes after coronary covered stent (CS) implantation and to compare the results according to the indications. BACKGROUND: To date, data on the long-term follow-up of coronary CS are limited, and no studies have been conducted to compare outcomes on the basis of specific lesions treated. METHODS: A total of 190 consecutive patients (212 lesions) implanted with CS and surviving until discharge between May 1997 and February 2017 were enrolled in this retrospective study. Clinical outcomes were evaluated and compared using the Gehan-Breslow-Wilcoxon test. RESULTS: CS was mainly used for the treatment of a saphenous vein graft (SVG) (51.4%), followed by coronary artery perforation (CAP) (25.0%) and coronary artery aneurysm (CAA) (11.8%). The median follow-up duration was 6.0 (interquartile range: 1.6-13.5) years. Target vessel myocardial infarction (MI), target vessel occlusion, target lesion revascularization, and stent thrombosis, frequently occurred in the early follow-up period (7.3%, 16.6%, 21.5%, and 8.9% at 1 year, respectively) and continued to increase throughout the long-term follow-up (14.8%, 38.6%, 38.7%, and 17.8% at 10 years, respectively). Target vessel occlusion, target vessel MI, and ST were not identified in CAA with superiority to CAP (Gehan-Breslow-Wilcoxon p-value = 0.010, 0.047, and 0.046, respectively). SVG had a higher rate of target vessel occlusion than CAA (p = 0.004). CONCLUSIONS: Clinical events after CS implantation frequently occurred in the early period and steadily increased in the long-term period. CS implantation in CAA was associated with fewer adverse cardiac events and may lead to safe and acceptable outcomes. However, CS implanted in CAP and SVG are associated with a high risk of long-term cardiac events.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea/instrumentación , Stents , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/fisiopatología , Bases de Datos Factuales , Femenino , Estudios de Seguimiento , Humanos , Italia , Masculino , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA