Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Cardiology ; : 1-9, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38934149

RESUMEN

INTRODUCTION: High-molecular-weight (HMW) von Willebrand factor (VWF) multimer deficiency occurs in classical low-flow, low-gradient (LF/LG) aortic stenosis (AS) due to shear force-induced proteolysis. The prognostic value of HMW VWF multimer deficiency is unknown. Therefore, we sought to evaluate the impact of HMW VWF multimer deficiency on clinical outcome. METHODS: In this prospective research study, a total of 83 patients with classical LF/LG AS were included. All patients underwent dobutamine stress echocardiography to distinguish true-severe (TS) from pseudo-severe (PS) classical LF/LG AS. HMW VWF multimer ratio was calculated using densitometric Western blot band quantification. The primary endpoint was all-cause mortality. RESULTS: Mean age was 79 ± 9 years, and TS classical LF/LG AS was diagnosed in 73% (n = 61) and PS classical LF/LG AS in 27% (n = 22) of all patients. Forty-six patients underwent aortic valve replacement (AVR) and 37 were treated conservatively. During a mean follow-up of 27 ± 17 months, 47 deaths occurred. Major bleeding complications after AVR (10/46; 22%) were more common in patients with HMW VWF multimer ratio <1 (8/17; 47%) in comparison to patients with a normal multimer pattern (2/29; 7%) at baseline (p = 0.003). In a multivariable Cox regression analysis, HMW VWF multimer deficiency was a predictor of all-cause mortality (HR: 3.02 [95% CI: 1.31-6.96], p = 0.009) in the entire cohort. This association was driven by higher mortality rates in the AVR group (multivariable-adjusted HR: 9.4; 95% CI 2.0-43.4, p = 0.004). CONCLUSIONS: This is the first study to demonstrate the predictive value of HMW VWF multimer ratio for risk stratification in patients with classical LF/LG AS. HMW VWF multimer deficiency was associated with an increased risk of all-cause mortality and major bleeding complications after AVR.

2.
Eur Heart J ; 43(41): 4421-4432, 2022 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-36036746

RESUMEN

AIMS: Sodium-glucose co-transporter 2 inhibition reduces the risk of hospitalization for heart failure and for death in patients with symptomatic heart failure. However, trials investigating the effects of this drug class in patients following acute myocardial infarction are lacking. METHODS AND RESULTS: In this academic, multicentre, double-blind trial, patients (n = 476) with acute myocardial infarction accompanied by a large creatine kinase elevation (>800 IU/L) were randomly assigned to empagliflozin 10 mg or matching placebo once daily within 72 h of percutaneous coronary intervention. The primary outcome was the N-terminal pro-hormone of brain natriuretic peptide (NT-proBNP) change over 26 weeks. Secondary outcomes included changes in echocardiographic parameters. Baseline median (interquartile range) NT-proBNP was 1294 (757-2246) pg/mL. NT-proBNP reduction was significantly greater in the empagliflozin group, compared with placebo, being 15% lower [95% confidence interval (CI) -4.4% to -23.6%] after adjusting for baseline NT-proBNP, sex, and diabetes status (P = 0.026). Absolute left-ventricular ejection fraction improvement was significantly greater (1.5%, 95% CI 0.2-2.9%, P = 0.029), mean E/e' reduction was 6.8% (95% CI 1.3-11.3%, P = 0.015) greater, and left-ventricular end-systolic and end-diastolic volumes were lower by 7.5 mL (95% CI 3.4-11.5 mL, P = 0.0003) and 9.7 mL (95% CI 3.7-15.7 mL, P = 0.0015), respectively, in the empagliflozin group, compared with placebo. Seven patients were hospitalized for heart failure (three in the empagliflozin group). Other predefined serious adverse events were rare and did not differ significantly between groups. CONCLUSION: In patients with a recent myocardial infarction, empagliflozin was associated with a significantly greater NT-proBNP reduction over 26 weeks, accompanied by a significant improvement in echocardiographic functional and structural parameters. CLINICALTRIALS.GOV REGISTRATION: NCT03087773.


Asunto(s)
Insuficiencia Cardíaca , Infarto del Miocardio , Humanos , Biomarcadores , Insuficiencia Cardíaca/tratamiento farmacológico , Infarto del Miocardio/tratamiento farmacológico , Péptido Natriurético Encefálico , Fragmentos de Péptidos/uso terapéutico , Volumen Sistólico , Función Ventricular Izquierda
3.
Rev Cardiovasc Med ; 23(7): 224, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39076911

RESUMEN

Background: Patients with severe aortic valve stenosis (AS) frequently present with pulmonary hypertension (PH). The gold standard for detection of pulmonary hypertension is right heart catheterization, which is not routinely performed as a preoperative standard in cardiology centers today, neither before surgical valve replacement nor before transcatheter aortic valve replacement (TAVR) procedure. Echocardiographic determination of systolic pulmonary artery pressure (sPAP) provides an opportunity to assess the presence or absence of PH. The aim of the present study was to investigate the extent to which plasma levels of common cardiovascular biomarkers behave in patients with severe AS and an sPAP < 40 mmHg in comparison to patients with an sPAP ≥ 40 mmHg. Methods: 179 patients with echocardiographic evidence of severe AS before TAVR procedure were divided into 2 groups based on sPAP. An sPAP of 40 mmHg was considered the cut-off value, with absence of PH defined by an sPAP < 40 mmHg (n = 82) and presence of PH defined by an sPAP ≥ 40 mmHg (n = 97). Directly before TAVR, a blood sample was drawn from each patient, and plasma concentrations of the cardiovascular biomarkers Soluble Suppression of Tumorigenicity-2 (sST2), Growth/Differentiation of Factor-15 (GDF-15), Heart-Type Fatty-Acid Binding Protein (H-FABP), Insulin Like Growth Factor Binding Protein 2 (IGF-BP2), Soluble Urokinase-Type Plasminogen Activator Receptor (suPAR), Brain Natriuretic Peptide (BNP) and Cardiac Troponin I (cTnI) were determined. Results: Patients with an sPAP ≥ 40 mmHg had significantly higher sST2 (p = 0.010), GDF-15 (p = 0.005), IGF-BP2 (p = 0.029), suPAR (p = 0.018), BNP (p < 0.001) and cTnI (p = 0.039) plasma levels. Only for H-FABP (p = 0.069), no significant differences were discernible between the two groups. In addition, cut-off values were calculated to predict an sPAP ≥ 40 mmHg. Significant results were shown with 16045.84 pg/mL for sST2 (p = 0.010), with 1117.54 pg/mL for GDF-15 (p = 0.005), with 107028.43 pg/mL for IGF-BP2 (p = 0.029), with 3782.84 pg/mL for suPAR (p = 0.018), with 2248.00 pg/mL for BNP (p < 0.001) and with 20.50 pg/mL for cTnI (p = 0.002). Conclusions: sPAP as an echocardiographic parameter in combination with supplementary use of cardiovascular biomarkers presented here have the potential to provide more detailed information about the presence or absence of PH in a non-invasive way.

4.
Wien Med Wochenschr ; 2022 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-36445602

RESUMEN

On the occasion of the reburial of Beethoven's mortal remains in 1863, skull fragments are said to have come into the possession of Prof. Dr. Seligmann, who was present at that time and had conducted scientific investigations. These fragments were inherited in his family and are currently housed in the USA. Their authenticity is doubted by some scientists. On the basis of a plaster cast of Beethoven's skull kept in the Natural History Museum, Fool's Tower, in Vienna, the exact topographical position of these skull fragments could be reconstructed and it could be shown that there is no indication that the fragments did not originate from Beethoven's skull.

5.
J Clin Lab Anal ; 35(11): e23977, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34562276

RESUMEN

BACKGROUND: Systemic inflammation has been identified as a major cardiovascular risk factor in patients undergoing transcatheter aortic valve replacement (TAVR), yet currently, it is not adequately portrayed in scores for pre-interventional risk assessment. The aim of this study was to investigate the predictive ability of TNF-α in TAVR. METHODS: A total of 431 patients undergoing transfemoral TAVR were enrolled in this study. Blood samples were drawn prior to intervention, 24 h post-intervention, 4, 5, and 7 days post-intervention, and 1, 3, and 6 months post-TAVR. RESULTS: In a univariate Cox proportional hazard analysis, plasma concentrations of TNF-α after 24 h and after 5 days were associated with mortality after 12 months (after 24 h: HR 1.002 (1.000-1.004), p = 0.028; after 5d: HR 1.003 (1.001-1.005), p = 0.013). This association remained significant even after correction for confounders in a multivariate Cox regression analysis. Additionally, cut-offs were calculated. Patients above the cut-off for TNF-α after 5d had a significantly worse 12-month mortality than patients below the cut-off (18.8% vs. 2.8%, p = 0.046). CONCLUSION: Plasma levels of TNF-α after 24 h and 5 days were independently associated with 12-month mortality in patients undergoing TAVR. Thus, TNF-α could represent a novel biomarker for enhanced risk stratification in these patients.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Factor de Necrosis Tumoral alfa/sangre , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Femenino , Humanos , Inflamación , Masculino , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad
6.
Wien Med Wochenschr ; 171(15-16): 356-362, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33765204

RESUMEN

Two different strands of hair taken from Beethoven's head after his death were examined for heavy metals using scanning electron microscopy (SEM) and laser ablation-ICP-MS (inductively coupled plasma-mass spectroscopy). The results revealed the presence of small lead particles on the surface of Beethoven's hairs and fluctuating lead levels in hair medulla along the length of the hair due to alternating lead exposure, with an average lead exposure of 100 times the normal value. The time-line attached to the peaks of these fluctuating values correlate with the pneumonia treatment and the paracenteses performed, including the subsequent treatment of the procedure wounds. While the administration of lead-containing drugs and treatments had been proven to resolve the pneumonia, it had simultaneously caused massive liver failure, accelerated by pre-existing cirrhosis. The question as to whether Beethoven's death was a case of malpractice can only be answered from a forensic point of view ex ante, since the state of the medical knowledge of the time has to be taken into account.


Asunto(s)
Personajes , Terapia por Láser , Mala Praxis , Humanos , Plomo
7.
Am Heart J ; 221: 39-47, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31901799

RESUMEN

BACKGROUND: Sodium glucose cotransporter 2 (SGLT2) inhibitors are established antidiabetic drugs with proven cardiovascular benefit. Although growing evidence suggests beneficial effects on myocardial remodeling, fluid balance and cardiac function, the impact of empagliflozin initiated early after acute myocardial infarction (AMI) has not been investigated yet. Therefore, the impact of EMpagliflozin on cardiac function and biomarkers of heart failure in patients with acute MYocardial infarction (EMMY) trial was designed to investigate the efficacy and safety of empagliflozin in diabetic and non-diabetic patients after severe AMI. METHODS: Within a multicenter, randomized, double-blind, placebo-controlled, phase 3b trial we will enroll patients with AMI and characteristics suggestive of severe myocardial necrosis are randomized in a 1:1 ratio to empagliflozin (10 mg once daily) or matching placebo. The primary endpoint is the impact of empagliflozin on changes in NT-proBNP within 6 months after AMI. Secondary endpoints include changes in echocardiographic parameters, levels of ketone body concentrations, HbA1c levels and body weight, respectively. Hospitalization rate due to heart failure or other causes, the duration of hospital stay and all-cause mortality will be assessed as exploratory secondary endpoints. DISCUSSION: The EMMY trial will test empagliflozin in patients with AMI regardless of their diabetic status. The EMMY trial may therefore underpin the concept of SGLT2 inhibition to improve cardiac remodeling, pre-and afterload reduction and cardiac metabolism regardless of its antidiabetic effects. Results will provide the rationale for the conduct of a cardiovascular outcome trial to test the effect of empagliflozin in patients with AMI.


Asunto(s)
Compuestos de Bencidrilo/uso terapéutico , Glucósidos/uso terapéutico , Insuficiencia Cardíaca/diagnóstico por imagen , Infarto del Miocardio/tratamiento farmacológico , Inhibidores del Cotransportador de Sodio-Glucosa 2/uso terapéutico , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/metabolismo , Método Doble Ciego , Ecocardiografía , Hemoglobina Glucada/metabolismo , Insuficiencia Cardíaca/metabolismo , Hospitalización , Humanos , Cuerpos Cetónicos/metabolismo , Tiempo de Internación , Mortalidad , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/metabolismo , Péptido Natriurético Encefálico/metabolismo , Fragmentos de Péptidos/metabolismo
8.
Int J Legal Med ; 134(6): 2121-2132, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32929594

RESUMEN

AIMS: The primary objective of this study was to investigate whether the fatalities of opioid abuse are not only related to respiratory depression but also as a result of other side effects such as emesis, delayed gastric emptying, a reduction of the cough reflex, and impaired consciousness leading to the aspiration of gastric contents, a finding regularly observed in drug-related deaths. DESIGN: A retrospective exploratory study analyzing heroin/morphine/methadone-related deaths submitted to court-ordered autopsy. SETTING: Center for Forensic Medicine, Medical University of Vienna, Austria (2010-2015). PARTICIPANTS: Two hundred thirty-four autopsy cases were included in the study: morphine (n = 200), heroin (n = 11), and methadone (n = 23) intoxication. FINDINGS: Analyses revealed that 41.88% of all deceased showed aspiration of gastric contents with equal gender distribution (p = 0.59). Aspiration was more frequent in younger deceased (χ2 = 8.7936; p = 0.012) and in deceased with higher body mass index (BMI) (χ2 = 6.2441; p = 0.044). Blood opioid concentration was lower in deceased with signs of aspiration than in non-aspirators (p = 0.013). Toxicological evaluation revealed a high degree of concomitant substance abuse (91%)-benzodiazepines (61.6%) and/or alcohol (21.8%). CONCLUSIONS: There are lower opioid concentrations in deceased with signs of aspiration, a fact which strongly points to aspiration as alternative cause of death in opioid-related fatalities. Furthermore, this study highlights the common abuse of slow-release oral morphine in Vienna and discusses alternative medications in substitution programs (buprenorphine/naloxone or tamper-resistant slow-release oral morphine preparations), as they might reduce intravenous abuse and opioid-related deaths.


Asunto(s)
Analgésicos Opioides/envenenamiento , Morfina/envenenamiento , Aspiración Respiratoria de Contenidos Gástricos/inducido químicamente , Trastornos Relacionados con Sustancias/sangre , Adolescente , Adulto , Anciano , Austria/epidemiología , Autopsia , Causas de Muerte , Femenino , Toxicología Forense , Heroína/envenenamiento , Humanos , Masculino , Metadona/envenenamiento , Persona de Mediana Edad , Estudios Retrospectivos , Trastornos Relacionados con Sustancias/mortalidad , Adulto Joven
9.
Solid State Nucl Magn Reson ; 109: 101685, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32932182

RESUMEN

Dynamic nuclear polarization (DNP) and indirect detection are two commonly applied approaches for enhancing the sensitivity of solid-state NMR spectroscopy. However, their use in tandem has not yet been investigated. With the advent of low-temperature fast magic angle spinning (MAS) probes with 1.3-mm diameter rotors capable of MAS at 40 â€‹kHz it becomes feasible to combine these two techniques. In this study, we performed DNP-enhanced 2D indirectly detected heteronuclear correlation (idHETCOR) experiments on 13C, 15N, 113Cd and 89Y nuclei in functionalized mesoporous silica, CdS nanoparticles, and Y2O3 nanoparticles. The sensitivity of the 2D idHETCOR experiments was compared with those of DNP-enhanced directly-detected 1D cross polarization (CP) and 2D HETCOR experiments performed with a standard 3.2-mm rotor. Due to low CP polarization transfer efficiencies and large proton linewidth, the sensitivity gains achieved by indirect detection alone were lower than in conventional (non-DNP) experiments. Nevertheless, despite the smaller sample volume the 2D idHETCOR experiments showed better absolute sensitivities than 2D HETCOR experiments for nuclei with the lowest gyromagnetic ratios. For 89Y, 2D idHETCOR provided 8.2 times better sensitivity than the 1 D89Y-detected CP experiment performed with a 3.2-mm rotor.

10.
Europace ; 21(1): 137-141, 2019 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-29986008

RESUMEN

AIMS: As in vivo real-life data are still scarce, we conducted a study to assess the safety and feasibility of cardiac magnetic resonance imaging (MRI) in patients with a leadless pacemaker system. METHODS AND RESULTS: In this prospective non-randomized interventional trial, we enrolled 15 patients with an MRI conditional Micra® leadless pacemaker system to undergo either a 1.5 T or 3.0 T cardiac MRI scan. Clinical adverse events as well as device parameters such as pacing threshold, sensing, impedance, and battery life were assessed at baseline as well as 1 and 3 months after the scan. Device parameter changes between different time points were tested for statistical significance and compared with pre-set cut-off values. Fourteen patients underwent the cardiac MRI scan according to the protocol as well as the scheduled follow-up visits. One participant was excluded from analysis, as the MRI scan was not possible because of severe claustrophobia. Other clinical events did not occur during the scan and the follow-up period. Device parameters stayed stable and changes during the observational period were statistically not significant (changes vs. baseline: pacing threshold: 0.01 ± 0.05 V, P = 0.308, 0.01 ± 0.07 V, P = 0.419, sensing: -0.15 ± 1.11 mV, P = 0.658, -0.19 ± 1.17 mV, P = 0.800, impedance: -7.86 ± 30.7 Ohm, P = 0.447, -7.86 ± 25.77 Ohm, P = 0.183, at 1 and 3 months follow-up, respectively). Parameter changes were not statistically different between patients who underwent imaging at 1.5 T (n = 7) or 3.0 T (n = 7). CONCLUSION: In our set of patients with a Micra® leadless pacemaker, cardiac magnetic resonance imaging at either 1.5 T or 3.0 T proved feasible and safe with no relevant changes in device parameters within 3 months of follow-up.


Asunto(s)
Estimulación Cardíaca Artificial , Imagen por Resonancia Magnética , Marcapaso Artificial , Adulto , Anciano , Anciano de 80 o más Años , Austria , Diseño de Equipo , Estudios de Factibilidad , Femenino , Humanos , Imagen por Resonancia Magnética/efectos adversos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Valor Predictivo de las Pruebas , Estudios Prospectivos , Falla de Prótesis , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
12.
Solid State Nucl Magn Reson ; 100: 63-69, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30965254

RESUMEN

The development of new, high-frequency solid-state diode sources capable of operating at 263 GHz, together with an optimized stator design for improved millimeter-wave coupling to the NMR sample, have enabled low-power DNP experiments at 263 GHz/400 MHz. With 250 mW output power, signal enhancements as high as 120 are achieved on standard samples - approximately 1/3 of the maximal enhancement available with high-power gyrotrons under similar conditions. Diode-based sources have a number of advantages over vacuum tube devices: they emit a pure mode, can be rapidly frequency-swept over a wide range of frequencies, have reproducible output power over this range, and have excellent output stability. By virtue of their small size, low thermal footprint, and lack of facility requirements, solid-state diodes are also considerably cheaper to operate and maintain than high-power vacuum tube devices. In light of these features, and anticipating further improvements in terms of available output power, solid-state diodes are likely to find widespread use in DNP and contribute to further advances in the field.

13.
Microcirculation ; 25(7): e12491, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30027659

RESUMEN

OBJECTIVE: Acute myocarditis is accompanied by an impaired coronary microcirculation. These microcirculatory disturbances are not well defined, and data are derived from complex invasive measurements. Therefore, this study aimed to evaluate the inflammation-induced microcirculatory dysfunction including its reversibility and association with markers of inflammation severity (extent of LGE on CMR imaging and laboratory markers of myocardial necrosis) using the noninvasive technique of echocardiographic CFR measurement. METHODS: Patients (n = 14) with clinically suspected acute myocarditis in the absence of coronary artery disease were prospectively enrolled, and echocardiographic CFR was determined by measuring peak diastolic coronary blood flow velocity at rest (PDV1) and under adenosine-induced hyperemia (PDV2) at baseline and 3-month follow-up. RESULTS: Eight of 14 (57.1%) patients showed an impaired baseline CFR (PDV2/PDV1 < 2). These patients were characterized by higher levels of cardiac troponin T (0.55 ± 0.39 vs 0.18 ± 0.08; P = 0.008) and larger areas of LGE on CMR. At 3-month follow-up, CFR was normal in all patients. CONCLUSION: A reversibly impaired coronary microcirculation is a frequent finding in acute myocarditis and is associated with markers of inflammation severity. Echocardiographic CFR measurement represents a feasible and safe method for its assessment.


Asunto(s)
Circulación Coronaria , Vasos Coronarios/fisiopatología , Microcirculación , Miocarditis/fisiopatología , Enfermedad Aguda , Velocidad del Flujo Sanguíneo , Vasos Coronarios/diagnóstico por imagen , Ecocardiografía , Femenino , Humanos , Inflamación/fisiopatología , Masculino , Persona de Mediana Edad , Miocarditis/diagnóstico por imagen , Medición de Riesgo
14.
Electrophoresis ; 39(4): 569-580, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29131355

RESUMEN

A fast and precise affinity capillary electrophoresis (ACE) method has been applied to investigate the interactions between two serum albumins (HSA and BSA) and heparinoids. Furthermore, different free flow electrophoresis methods were developed to separate the species which appears owing to interaction of albumins with pentosan polysulfate sodium (PPS) under different experimental conditions. For ACE experiments, the normalized mobility ratios (∆R/Rf ), which provided information about the binding strength and the overall charge of the protein-ligand complex, were used to evaluate the binding affinities. ACE experiments were performed at two different temperatures (23 and 37°C). Both BSA and HSA interact more strongly with PPS than with unfractionated and low molecular weight heparins. For PPS, the interactions can already be observed at low mg/L concentrations (3 mg/L), and saturation is already obtained at approximately 20 mg/L. Unfractionated heparin showed almost no interactions with BSA at 23°C, but weak interactions at 37°C at higher heparin concentrations. The additional signals also appeared at higher concentrations at 37°C. Nevertheless, in most cases the binding data were similar at both temperatures. Furthermore, HSA showed a characteristic splitting in two peaks especially after interacting with PPS, which is probably attributable to the formation of two species or conformational change of HSA after interacting with PPS. The free flow electrophoresis methods have confirmed and completed the ACE experiments.


Asunto(s)
Electroforesis Capilar/métodos , Heparinoides/química , Heparinoides/metabolismo , Albúmina Sérica/química , Albúmina Sérica/metabolismo , Humanos , Poliéster Pentosan Sulfúrico/química , Poliéster Pentosan Sulfúrico/metabolismo , Unión Proteica , Temperatura
15.
J Cardiovasc Magn Reson ; 20(1): 47, 2018 07 05.
Artículo en Inglés | MEDLINE | ID: mdl-29973228

RESUMEN

BACKGROUND: There are limited data on patients with leadless cardiac pacemakers (LCP) undergoing magnetic resonance imaging. The aim of this prospective, single-center, observational study was to evaluate artefacts on cardiovascular magnetic resonance (CMR) images in patients with LCP. METHODS: Fifteen patients with Micra™ LCP, implanted at least 6 weeks prior to CMR scan, were enrolled and underwent either 1.5 Tesla or 3 Tesla CMR imaging. Artefacts were categorized into grade 1 (excellent image quality), grade 2 (good), grade 3 (poor) and grade 4 (non-diagnostic) for each myocardial segment. One patient was excluded because of an incomplete CMR investigation due to claustrophobia. RESULTS: LCP caused an arc-shaped artefact (0.99 ± 0.16 cm2) at the right ventricular (RV) apex. Of 224 analyzed myocardial segments of the left ventricle (LV) 158 (70.5%) were affected by grade 1, 27 (12.1%) by grade 2, 17 (7.6%) by grade 3 and 22 (9.8%) by grade 4 artefacts. The artefact burden of grade 3 and 4 artefacts was significantly higher in the 3 Tesla group (3 Tesla vs 1.5 Tesla: 3.7 ± 1.6 vs 1.9 ± 1.4 myocardial segments per patient, p = 0.03). A high artefact burden was particularly observed in the mid anteroseptal, inferoseptal and apical septal myocardial segments of the LV and in the mid and apical segments of the RV. Quantification of LV function and assessment of valves were feasible in all patients. We did not observe any clinical or device-related adverse events. CONCLUSION: CMR imaging in patients with LCP is feasible with excellent to good image quality in the majority of LV segments. The artefact burden is comparable small allowing an accurate evaluation of LV function, cardiac structures and valves. However, artefacts in the mid anteroseptal, inferoseptal and apical septal myocardial segments of the LV due to the LCP may impair or even exclude diagnostic evaluation of these segments. Artefacts on CMR images may be reduced by the use of 1.5 Tesla CMR scanners.


Asunto(s)
Artefactos , Corazón/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Marcapaso Artificial/efectos adversos , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Corazón/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Función Ventricular Izquierda
16.
Proc Natl Acad Sci U S A ; 112(32): 9896-901, 2015 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-26216996

RESUMEN

Channelrhodopsin-2 from Chlamydomonas reinhardtii is a light-gated ion channel. Over recent years, this ion channel has attracted considerable interest because of its unparalleled role in optogenetic applications. However, despite considerable efforts, an understanding of how molecular events during the photocycle, including the retinal trans-cis isomerization and the deprotonation/reprotonation of the Schiff base, are coupled to the channel-opening mechanism remains elusive. To elucidate this question, changes of conformation and configuration of several photocycle and conducting/nonconducting states need to be determined at atomic resolution. Here, we show that such data can be obtained by solid-state NMR enhanced by dynamic nuclear polarization applied to (15)N-labeled channelrhodopsin-2 carrying 14,15-(13)C2 retinal reconstituted into lipid bilayers. In its dark state, a pure all-trans retinal conformation with a stretched C14-C15 bond and a significant out-of-plane twist of the H-C14-C15-H dihedral angle could be observed. Using a combination of illumination, freezing, and thermal relaxation procedures, a number of intermediate states was generated and analyzed by DNP-enhanced solid-state NMR. Three distinct intermediates could be analyzed with high structural resolution: the early [Formula: see text] K-like state, the slowly decaying late intermediate [Formula: see text], and a third intermediate populated only under continuous illumination conditions. Our data provide novel insight into the photoactive site of channelrhodopsin-2 during the photocycle. They further show that DNP-enhanced solid-state NMR fills the gap for challenging membrane proteins between functional studies and X-ray-based structure analysis, which is required for resolving molecular mechanisms.


Asunto(s)
Chlamydomonas reinhardtii/metabolismo , Luz , Espectroscopía de Resonancia Magnética , Rodopsina/metabolismo , Isótopos de Carbono , Dominio Catalítico , Oscuridad , Membrana Dobles de Lípidos/metabolismo , Isótopos de Nitrógeno , Multimerización de Proteína , Rodopsina/química
17.
J Am Chem Soc ; 139(31): 10609-10612, 2017 08 09.
Artículo en Inglés | MEDLINE | ID: mdl-28692804

RESUMEN

Dynamic nuclear polarization (DNP) has recently emerged as a tool to enhance the sensitivity of solid-state NMR experiments. However, so far high enhancements (>100) are limited to relatively low magnetic fields, and DNP at fields higher than 9.4 T significantly drops in efficiency. Here we report solid-state Overhauser effect DNP enhancements of over 100 at 18.8 T. This is achieved through the unexpected discovery that enhancements increase rapidly with increasing magic angle spinning (MAS) rates. The measurements are made using 1,3-bisdiphenylene-2-phenylallyl dissolved in o-terphenyl at 40 kHz MAS. We introduce a source-sink diffusion model for polarization transfer which is capable of explaining the experimental observations. The advantage of this approach is demonstrated on mesoporous alumina with the acquisition of well-resolved DNP surface-enhanced 27Al cross-polarization spectra.

18.
Electrophoresis ; 38(12): 1560-1571, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28256735

RESUMEN

A fast and precise affinity capillary electrophoresis (ACE) method has been developed and applied for the investigation of the binding interactions between P-selectin and heparinoids as potential P-selectin inhibitors in the presence and absence of calcium ions. Furthermore, model proteins and vitronectin were used to appraise the binding behavior of P-selectin. The normalized mobility ratios (∆R/Rf ), which provided information about the binding strength and the overall charge of the protein-ligand complex, were used to evaluate the binding affinities. It was found that P-selectin interacts more strongly with heparinoids in the presence of calcium ions. P-selectin was affected by heparinoids at the concentration of 3 mg/L. In addition, the results of the ACE experiments showed that among other investigated proteins, albumins and vitronectin exhibited strong interactions with heparinoids. Especially with P-selectin and vitronectin, the interaction may additionally induce conformational changes. Subsequently, computational models were applied to interpret the ACE experiments. Docking experiments explained that the binding of heparinoids on P-selectin is promoted by calcium ions. These docking models proved to be particularly well suited to investigate the interaction of charged compounds, and are therefore complementary to ACE experiments.


Asunto(s)
Heparinoides/química , Selectina-P/química , Proteínas/química , Sitios de Unión , Calcio , Simulación por Computador , Electroforesis Capilar , Iones , Ligandos , Protaminas/química , Unión Proteica
19.
Eur J Clin Invest ; 47(2): 149-157, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28036122

RESUMEN

BACKGROUND: Soluble ST2 (sST2) has been introduced as a novel biomarker in patients suffering from heart failure for risk stratification. In this study, we sought to investigate whether sST2 is useful for risk stratification and prediction of mortality in patients undergoing transcatheter aortic valve implantation (TAVI). MATERIALS AND METHODS: A total of 274 patients undergoing TAVI were included in this study (149 female; age 81 ± 1 years; EUROSCORE 25 ± 1; STS score 3·8 ± 0·2). Plasma samples were obtained preinterventional and analysed for sST2. Patients were followed up 1 month and 1 year after TAVI. RESULTS: In a Cox regression analysis, sST2 plasma concentration was associated with increased mortality (changes per pg/mL sST2 concentration; HR 1·00006 95% (1·00004-1·00009); P < 0·001). A cut-off by means of the Youden Index was calculated (10 070·27 pg/mL), and patients were retrospectively divided into two cohorts, in those above (31·3%) and those below (68·7%) this value. These two groups were then compared regarding mortality both after 30 days and 1 year: whereas 1-month mortality did not differ (7·0% vs. 10·3%, OR 1·50 95% CI (0·60-3·79; P = 0·46)), patients with a sST2 concentration above the cut-off of 10 070·27 pg/mL showed a significantly worse outcome after 1 year (49·2% vs. 23·2%; OR 3·21 95% CI (1·70-6·04); P < 0·001). After correction for confounders in a multivariate Cox regression analysis, sST2 (1·0002 95% CI (1·0001-1·0003); P = 0·001) concentration remained associated with mortality. CONCLUSIONS: sST2 levels were associated with 1-year mortality after TAVI. Based on these results, we assume that sST2 might help to identify patients at high risk for death in whom conservative treatment should be considered.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Proteína 1 Similar al Receptor de Interleucina-1/metabolismo , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Estenosis de la Válvula Aórtica/sangre , Estenosis de la Válvula Aórtica/mortalidad , Estudios de Cohortes , Femenino , Humanos , Masculino , Volumen Sistólico/fisiología , Resultado del Tratamiento
20.
Phys Chem Chem Phys ; 18(15): 10616-22, 2016 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-27035630

RESUMEN

DNP-enhanced solid-state NMR spectroscopy under magic angle spinning (MAS) is rapidly developing into a powerful analytical tool to investigate the structure of a wide range of solid materials, because it provides unsurpassed sensitivity gains. Most developments and applications of DNP MAS NMR were so far reported at moderate spinning frequencies (up to 14 kHz using 3.2 mm rotors). Here, using a 1.3 mm MAS DNP probe operating at 18.8 T and ∼100 K, we show that signal amplification factors can be increased by up to a factor two when using smaller volume rotors as compared to 3.2 mm rotors, and report enhancements of around 60 over a range of sample spinning rates from 10 to 40 kHz. Spinning at 40 kHz is also shown to increase (29)Si coherence lifetimes by a factor three as compared to 10 kHz, substantially increasing sensitivity in CPMG type experiments. The contribution of quenching effects to the overall sensitivity gain at very fast MAS is evaluated, and applications are reported on a functionalised mesostructured organic-inorganic material.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA