Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Neth Heart J ; 2024 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-39283568

RESUMEN

BACKGROUND: Transcatheter mitral valve replacement (TMVR) has emerged as a minimally invasive alternative to mitral valve surgery for patients at high or prohibitive operative risk. Prospective studies reported favourable outcomes in patients with annulus calcification (valve-in-mitral annulus calcification; ViMAC), failed annuloplasty ring (mitral valve-in-ring; MViR), and bioprosthetic mitral valve dysfunction (mitral valve-in-valve; MViV). Multi-slice computed tomography (MSCT)-derived 3D-modelling and simulations may provide complementary anatomical perspectives for TMVR planning. AIMS: We aimed to illustrate the implementation of MSCT-derived modelling and simulations in the workup of TMVR for ViMAC, MViR, and MViV. METHODS: For this retrospective study, we included all consecutive patients screened for TMVR and compared MSCT data, echocardiographic outcomes and clinical outcomes. RESULTS: Sixteen out of 41 patients were treated with TMVR (ViMAC n = 9, MViR n = 3, MViV n = 4). Eleven patients were excluded for inappropriate sizing, 4 for anchoring issues and 10 for an unacceptable risk of left ventricular outflow tract obstruction (LVOTO) based on 3D modelling. There were 3 procedure-related deaths and 1 non-procedure-related cardiovascular death during 30 days of follow-up. LVOTO occurred in 3 ViMAC patients and 1 MViR patient, due to deeper valve implantation than planned in 3 patients, and anterior mitral leaflet displacement with recurrent basal septum thickening in 1 patient. TMVR significantly reduced mitral mean gradients as compared with baseline measurements (median mean gradient 9.5 (9.0-11.5) mm Hg before TMVR versus 5.0 (4.5-6.0) mm Hg after TMVR, p = 0.03). There was no residual mitral regurgitation at 30 days. CONCLUSION: MSCT-derived 3D modelling and simulation provide valuable anatomical insights for TMVR with transcatheter balloon expandable valves in ViMAC, MViR and MViV. Further planning iterations should target the persistent risk for neo-LVOTO.

2.
Catheter Cardiovasc Interv ; 91(4): 790-797, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-28895285

RESUMEN

OBJECTIVES: To evaluate the value of left vertebral artery filter protection in addition to the current filter-based embolic protection technology to achieve complete cerebral protection during TAVR. BACKGROUND: The occurrence of cerebrovascular events after transcatheter aortic valve replacement (TAVR) has fueled concern for its potential application in younger patients with longer life expectancy. Transcatheter cerebral embolic protection (TCEP) devices may limit periprocedural cerebrovascular events by preventing macro and micro-embolization to the brain. Conventional filter-based TCEP devices cover three extracranial contributories to the brain, yet leave the left vertebral artery unprotected. METHODS: Patients underwent TAVR with complete TCEP. A dual-filter system was deployed in the brachiocephalic trunk and left common carotid artery with an additional single filter in the left vertebral artery. After TAVR all filters were retrieved and sent for histopathological evaluation by an experienced pathologist. RESULTS: Eleven patients received a dual-filter system and nine of them received an additional left vertebral filter. In the remaining two patients, the left vertebral filter could not be deployed. No periprocedural strokes occurred. We found debris in all filters, consisting of thrombus, tissue derived debris, and foreign body material. The left vertebral filter contained debris in an equal amount of patients as the Sentinel filters. The size of the captured particles was similar between all filters. CONCLUSIONS: The left vertebral artery is an important entry route for embolic material to the brain during TAVR. Selective filter protection of the left vertebral artery revealed embolic debris in all patients. The clinical value of complete filter-based TCEP during TAVR warrants further research.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Tronco Braquiocefálico , Arteria Carótida Común , Dispositivos de Protección Embólica , Prótesis Valvulares Cardíacas , Embolia Intracraneal/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Arteria Vertebral , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Tronco Braquiocefálico/diagnóstico por imagen , Tronco Braquiocefálico/patología , Arteria Carótida Común/diagnóstico por imagen , Arteria Carótida Común/patología , Angiografía por Tomografía Computarizada , Femenino , Humanos , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/etiología , Embolia Intracraneal/patología , Masculino , Estudios Prospectivos , Diseño de Prótesis , Factores Protectores , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Arteria Vertebral/diagnóstico por imagen , Arteria Vertebral/patología
3.
Artículo en Inglés | MEDLINE | ID: mdl-38970592

RESUMEN

Inter-echocardiography core laboratory (ECL) harmonization is pivotal to consider data from different ECLs interchangeable. On the basis of the experience of the first trans-Atlantic harmonization of 2 established ECLs in the field of transcatheter aortic valve replacement (TAVR) trials, this review describes the harmonized ECL methodology in analyzing and adjudicating the post-TAVR echocardiographic endpoints according to Valve Academic Research Consortium 3 definitions. This review presents the feasibility and intra- and inter-ECL reproducibility, explains the root cause of potential important inter-ECL variability, and formulates ECL recommendations for optimal post-TAVR echocardiographic image acquisition. The implementation of inter-ECL harmonization may further define the best practice of ECLs and have logistic and regulatory implications for the realization of future TAVR trials.

4.
JACC Case Rep ; 29(3): 102193, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38361565

RESUMEN

Left ventricular outflow tract obstruction (LVOTO) is a notorious complication of transcatheter mitral valve replacement (TMVR). Computed tomography-derived simulations can predict neo-LVOTO post-TMVR, whereas alcohol septal ablation (ASA) can mitigate neo-LVOTO risk. We report a case of sequential ASA of 2 adjacent septal branches to resolve unexpected neo-LVOTO post-TMVR.

5.
J Cardiovasc Imaging ; 31(3): 135-141, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37488918

RESUMEN

BACKGROUND: Global longitudinal strain (GLS) is an accurate and reproducible parameter of left ventricular (LV) systolic function which has shown meaningful prognostic value. Fast, user-friendly, and accurate tools are required for its widespread implementation. We aim to compare a novel web-based tool with two established algorithms for strain analysis and test its reproducibility. METHODS: Thirty echocardiographic datasets with focused LV acquisitions were analyzed using three different semi-automated endocardial GLS algorithms by two readers. Analyses were repeated by one reader for the purpose of intra-observer variability. CAAS Qardia (Pie Medical Imaging) was compared with 2DCPA and AutoLV (TomTec). RESULTS: Mean GLS values were -15.0 ± 3.5% from Qardia, -15.3 ± 4.0% from 2DCPA, and -15.2 ± 3.8% from AutoLV. Mean GLS between Qardia and 2DCPA were not statistically different (p = 0.359), with a bias of -0.3%, limits of agreement (LOA) of 3.7%, and an intra-class correlation coefficient (ICC) of 0.88. Mean GLS between Qardia and AutoLV were not statistically different (p = 0.637), with a bias of -0.2%, LOA of 3.4%, and an ICC of 0.89. The coefficient of variation (CV) for intra-observer variability was 4.4% for Qardia, 8.4% 2DCPA, and 7.7% AutoLV. The CV for inter-observer variability was 4.5%, 8.1%, and 8.0%, respectively. CONCLUSIONS: In echocardiographic datasets of good image quality analyzed at an independent core laboratory using a standardized annotation method, a novel web-based tool for GLS analysis showed consistent results when compared with two algorithms of an established platform. Moreover, inter- and intra-observer reproducibility results were excellent.

8.
J Cardiovasc Surg (Torino) ; 58(4): 598-605, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28128540

RESUMEN

BACKGKGROUND: The aim of this paper was to explore the determinants of aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI) using multi-slice computed tomography (MSCT) instead of echocardiography-guided sizing. METHODS: Determinants of AR were assessed in 313 consecutive patients who underwent TAVI with the Medtronic (MCS, N.=259) or Edwards Sapien or XT (ESV, N.=54) using MSCT-guided sizing. AR was assessed by angiography immediately after TAVI (N.=313, Sellers) and by echocardiography at discharge (N.=285, VARC-2). Distinction was made between patients with grade 0-1 and grade ≥2 AR post-TAVI. RESULTS: AR≥2 post-TAVI was seen in 91 patients or 29% (MCS 85/259: 33% vs. ESV 6/54:11%) by angiography and 94 patients or 33% (MCS 87/239:36% vs. ESV 7/46:15%) by echocardiography. By univariable analysis, patients with AR≥2 post TAVI had more AR≥2 at baseline (70% vs. 52%, P=0.003), a larger mean and maximal annulus diameter (25.0 [23.5-26.3] vs. 24.0 [22.6-26.0], P=0.025 and 27.9±2.7 mm vs. 27.0±2.8 mm, P=0.018, respectively) and a higher Agatston Score (3.9 [2.9-5.3] vs. 2.6 [1.8-3.8], P≤0.001). AR≥2 post-TAVI was more frequent after MCS than ESV (33% vs. 11%, P=0.001). There was no difference in nominal valve size relative to the patient's annulus, nor depth of implantation. By propensity score adjusted multivariable analysis, AR≥2 at baseline (odds 2.407 [95% CI: 1.472-3.938]) but above all MCS (odds: 6.047 [95% CI; 1.307- 27.976]) were independent determinants of AR≥2 post-TAVI. The latter was also confirmed by propensity score adjusted multivariable analysis in the echocardiography population (N.=285) (odds: 5.259 [95% CI; 1.070-25.851]). CONCLUSIONS: AR≥2 is more prevalent after MCS valve implantation and is an independent determinant of AR also when using MSCT guided-sizing.


Asunto(s)
Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/diagnóstico por imagen , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Tomografía Computarizada Multidetector , Diseño de Prótesis , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Distribución de Chi-Cuadrado , Ecocardiografía Doppler , Femenino , Humanos , Modelos Logísticos , Masculino , Análisis Multivariante , Oportunidad Relativa , Valor Predictivo de las Pruebas , Puntaje de Propensión , Factores de Riesgo , Resultado del Tratamiento
9.
JACC Cardiovasc Interv ; 9(5): 508-12, 2016 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-26965945
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA