Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Biomed Opt ; 12(5): 051604, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17994873

RESUMEN

This research describes a noninvasive, noncontact method used to quantitatively analyze the functional characteristics of tissue. Multispectral images collected at several near-infrared wavelengths are input into a mathematical optical skin model that considers the contributions from different analytes in the epidermis and dermis skin layers. Through a reconstruction algorithm, we can quantify the percent of blood in a given area of tissue and the fraction of that blood that is oxygenated. Imaging normal tissue confirms previously reported values for the percent of blood in tissue and the percent of blood that is oxygenated in tissue and surrounding vasculature, for the normal state and when ischemia is induced. This methodology has been applied to assess vascular Kaposi's sarcoma lesions and the surrounding tissue before and during experimental therapies. The multispectral imaging technique has been combined with laser Doppler imaging to gain additional information. Results indicate that these techniques are able to provide quantitative and functional information about tissue changes during experimental drug therapy and investigate progression of disease before changes are visibly apparent, suggesting a potential for them to be used as complementary imaging techniques to clinical assessment.


Asunto(s)
Dermoscopía/métodos , Hemoglobinas/análisis , Interpretación de Imagen Asistida por Computador/métodos , Sarcoma de Kaposi/patología , Neoplasias Cutáneas/patología , Espectrofotometría Infrarroja/métodos , Biomarcadores/análisis , Humanos , Sarcoma de Kaposi/metabolismo , Neoplasias Cutáneas/metabolismo
2.
Biomed Opt Express ; 3(1): 192-205, 2012 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-22254179

RESUMEN

In this paper we discuss results based on using instrumental motion as a signal rather than treating it as noise in Near Infra-Red (NIR) imaging. As a practical application to demonstrate this approach we show the design of a novel NIR hematoma detection device. The proposed device is based on a simplified single source configuration with a dual separation detector array and uses motion as a signal for detecting changes in blood volume in the dural regions of the head. The rapid triage of hematomas in the emergency room will lead to improved use of more sophisticated/expensive imaging facilities such as CT/MRI units. We present simulation results demonstrating the viability of such a device and initial phantom results from a proof of principle device. The results demonstrate excellent localization of inclusions as well as good quantitative comparisons.

3.
Biomed Opt Express ; 2(5): 1040-58, 2011 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-21559118

RESUMEN

We describe a novel reconstruction algorithm based on Principal Component Analysis (PCA) applied to multi-spectral imaging data. Using numerical phantoms, based on a two layered skin model developed previously, we found analytical expressions, which convert qualitative PCA results into quantitative blood volume and oxygenation values, assuming the epidermal thickness to be known. We also evaluate the limits of accuracy of this method when the value of the epidermal thickness is not known. We show that blood volume can reliably be extracted (less than 6% error) even if the assumed thickness deviates 0.04mm from the actual value, whereas the error in blood oxygenation can be as large as 25% for the same deviation in thickness. This PCA based reconstruction was found to extract blood volume and blood oxygenation with less than 8% error, if the underlying structure is known. We then apply the method to in vivo multi-spectral images from a healthy volunteer's lower forearm, complemented by images of the same area using Optical Coherence Tomography (OCT) for measuring the epidermal thickness. Reconstruction of the imaging results using a two layered analytical skin model was compared to PCA based reconstruction results. A point wise correlation was found, showing the proof of principle of using PCA based reconstruction for blood volume and oxygenation extraction.

4.
J Biomed Opt ; 15(4): 046007, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20799809

RESUMEN

Multispectral images of skin contain information on the spatial distribution of biological chromophores, such as blood and melanin. From this, parameters such as blood volume and blood oxygenation can be retrieved using reconstruction algorithms. Most such approaches use some form of pixelwise or volumetric reconstruction code. We explore the use of principal component analysis (PCA) of multispectral images to access blood volume and blood oxygenation in near real time. We present data from healthy volunteers under arterial occlusion of the forearm, experiencing ischemia and reactive hyperemia. Using a two-layered analytical skin model, we show reconstruction results of blood volume and oxygenation and compare it to the results obtained from our new spectral analysis based on PCA. We demonstrate that PCA applied to multispectral images gives near equivalent results for skin chromophore mapping and quantification with the advantage of being three orders of magnitude faster than the reconstruction algorithm.


Asunto(s)
Determinación del Volumen Sanguíneo/métodos , Isquemia/metabolismo , Oximetría/métodos , Oxígeno/análisis , Piel/irrigación sanguínea , Piel/metabolismo , Análisis Espectral/métodos , Algoritmos , Sistemas de Computación , Interpretación Estadística de Datos , Humanos , Análisis de Componente Principal
5.
J Biomed Opt ; 15(4): 046013, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20799815

RESUMEN

Noncontact optical imaging of curved objects can result in strong artifacts due to the object's shape, leading to curvature biased intensity distributions. This artifact can mask variations due to the object's optical properties, and makes reconstruction of optical/physiological properties difficult. In this work we demonstrate a curvature correction method that removes this artifact and recovers the underlying data, without the necessity of measuring the object's shape. This method is applicable to many optical imaging modalities that suffer from shape-based intensity biases. By separating the spatially varying data (e.g., physiological changes) from the background signal (dc component), we show that the curvature can be extracted by either averaging or fitting the rows and columns of the images. Numerical simulations show that our method is equivalent to directly removing the curvature, when the object's shape is known, and accurately recovers the underlying data. Experiments on phantoms validate the numerical results and show that for a given image with 16.5% error due to curvature, the method reduces that error to 1.2%. Finally, diffuse multispectral images are acquired on forearms in vivo. We demonstrate the enhancement in image quality on intensity images, and consequently on reconstruction results of blood volume and oxygenation distributions.


Asunto(s)
Algoritmos , Antebrazo/anatomía & histología , Aumento de la Imagen/métodos , Análisis Espectral/métodos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
J Microsc ; 228(Pt 3): 330-7, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18045327

RESUMEN

We have constructed a device that maximizes the probability of collecting all of the scattered and ballistic light isotropically generated at the focal spot of multiphoton excited emissions (MPE) to optimize the signal-to-noise ratio (SNR) for micro-imaging. This was accomplished by optically coupling a parabolic reflector (that surrounds the sample and top of the objective) to a pair of collimating lenses (above the sample) that redirects emitted light to a separate detector. These additional optics, combined with the objective, allow the total emission detection (TED) condition to be approached. Numerical simulations suggest an approximately 10-fold improvement in SNR with TED. Comparisons between the objective detection and TED reveal an enhancement of 8.9 in SNR (77% of predicted) for GFP-labelled brain slices and similar results for fluorescent beads. This increase in SNR can be used to improve time resolution, reduce laser power requirements/photodynamic damage, and, in certain cases, detection depth, for MPE imaging techniques.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA