1.
Water Sci Technol ; 83(2): 331-343, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33504698

RESUMEN

Municipal wastewater phycoremediation represents a promising circular economy-based process for wastewater reclamation used to recover water and produce biomass. This study aimed to evaluate a pilot-scale phycoremediation system, using the most efficient strain of microalgae for wastewater reclamation in the Atacama Desert. Nitrogen and phosphorus removal, as well as biomass growth, were compared in different microalgae treatments, namely Muriellopsis sp., Scenedesmus almeriensis, Chlamydomonas segnis, Chlorella pyrenoidosa and Chlorella vulgaris. The most efficient treatments, Muriellopsis sp. and S. almeriensis, were scaled up to 20-L bubble column reactors to evaluate nutrient removal and biomass biochemical profile for potential biotechnological application. Finally, Muriellopsis sp. was selected for a pilot-scale phycoremediation experiment (800-L raceway), which removed 84% of nitrogen, 93% of phosphorus and other chemical compounds after 4 days of treatment to meet most of the Chilean standards for irrigation water (NCh. 1333. DS. MOP No. 867/78). Faecal coliforms count was reduced by 99.9%. Furthermore, biomass productivity reached 104.25 mg·L-1·day-1 value with 51% protein, and pigment content of 0.6% carotenoid, with 0.3% lutein. These results indicate the potential of wastewater phycoremediation at an industrial scale for the production of irrigation water and carotenoid using Muriellopsis sp.


Asunto(s)
Chlorella vulgaris , Microalgas , Biomasa , Chile , Nitrógeno , Fósforo , Aguas Residuales/análisis
2.
Allergol Immunopathol (Madr) ; 44(2): 106-12, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26001339

RESUMEN

BACKGROUND: Ciclesonide (CIC) is an effective inhaled corticosteroid for treating asthmatic children. However, its effect on airway inflammation assessed by the fraction of exhaled nitric oxide (FENO) in children with persistent asthma is virtually unknown. We aimed to assess the effect of once-daily generic CIC, 80 or 160 µg, on FENO, lung function, asthma control and bronchial hyperresponsiveness, in atopic children with persistent asthma. METHODS: This was a 12-week, randomised, double-blind, parallel-group study. Sixty children with mild-to-moderate persistent asthma were recruited. Changes in FENO, asthma control score, lung function (FEV1) and bronchial hyperresponsiveness to methacholine (BHR) were used to assess the effects of both CIC doses. Non-normally distributed variables were log-transformed to approximate normality, and parametric tests were used for comparisons within and between groups at baseline and after 12 weeks of treatment. RESULTS: In the CIC 80 µg group, FENO decreased from 45.0 ppb (95% CI 37.8-53.7) to 32.7 ppb (95% CI 21.0-47.3) at the end of study (P=0.021), whereas in the CIC 160 µg group, FENO decreased from 47.3 ppb (95% CI 40.4-55.3) to 30.5 ppb (95% CI 24.1-38.7) (P<0.001). The difference between groups in FENO at the end of study was not significant (P=0.693). There was a significant improvement of asthma control with both CIC doses but there was no significant change in BHR or FEV1 in either group. CONCLUSION: Once-daily generic ciclesonide (80 µg or 160 µg), for 12 weeks, is effective to improve airway inflammation and asthma control in atopic children with persistent asthma.


Asunto(s)
Antialérgicos/uso terapéutico , Asma/tratamiento farmacológico , Medicamentos Genéricos/uso terapéutico , Espiración/efectos de los fármacos , Hipersensibilidad Inmediata/tratamiento farmacológico , Pregnenodionas/uso terapéutico , Adolescente , Pruebas Respiratorias , Pruebas de Provocación Bronquial , Niño , Chile , Protocolos Clínicos , Estudios de Seguimiento , Humanos , Óxido Nítrico/análisis
3.
Allergol Immunopathol (Madr) ; 43(6): 528-32, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25456527

RESUMEN

BACKGROUND: The fraction of exhaled nitric oxide (FENO) measured using portable devices is increasingly used in the clinical setting to assess asthmatic children. However, there is little and variable information on the reference values obtained using these devices in healthy children from different populations. METHODS: 190 healthy non-smoker children (8-15 years old) were randomly selected from public schools participating in this study. The objective was to determine FENO reference values for healthy Chilean schoolchildren. Healthy individuals were identified by medical interview and parent questionnaire on the use of asthma medications, and current and past symptoms of asthma, rhinoconjunctivitis and eczema. FENO was measured at schools using a portable device with electrochemical sensor (NIO MINOX). Reference values of FENO were expressed as geometric mean and upper limit of the 95% reference interval (right-sided). The relationship of FENO with gender, age, height, body mass, and other factors was assessed by multiple regression, and the difference between groups was contrasted by ANOVA. RESULTS: The FENO geometric mean was 15.4ppb with a 95% reference interval upper limit (right-sided), of 27.4ppb (90%CI 25.6-29.2). The 5th and 95th percentiles were 9.0ppb and 28.0ppb, respectively. Height was the only factor significantly associated to FENO (p=0.022). There was no significant difference in mean FENO regarding age, gender, weight, parent reported rhinoconjunctivitis and eczema. CONCLUSION: This study suggests that FENO values higher than 27ppb are likely to be abnormal and would reflect airway inflammation in children as those in the present study.


Asunto(s)
Asma/diagnóstico , Pruebas Respiratorias/métodos , Óxido Nítrico/metabolismo , Adolescente , Estatura , Niño , Chile , Equipos y Suministros , Espiración , Femenino , Humanos , Masculino , Población , Valores de Referencia
4.
AJNR Am J Neuroradiol ; 42(6): 1087-1092, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33858823

RESUMEN

BACKGROUND AND PURPOSE: Few reports described flow diversion for ICA bifurcation aneurysms. Our aim was to provide further insight into flow diversion for ICA bifurcation aneurysms difficult to treat with other strategies. MATERIALS AND METHODS: Consecutive patients receiving flow diverters for unruptured ICA bifurcation aneurysms were collected. Aneurysm occlusion (O'Kelly-Marotta grading scale) and clinical outcomes were evaluated. RESULTS: Twenty saccular ICA bifurcation aneurysms were treated with the Pipeline Embolization Device deployed from the M1 to the ICA, covering the aneurysm and the A1 segment. All patients presented with an angiographic visualized contralateral flow from the anterior communicating artery. Mean aneurysm size was 6.5 (SD, 3.2) mm (range, 4.5-20 mm). All lesions had an unfavorable dome-to-neck ratio (mean/median, 1.6/1.6; range, 0.8-2.8; interquartile range = 0.5) or aspect ratio for coiling (mean/median = 1.5/1.55; range, 0.8-2.5; interquartile range = 0.6). One was a very large aneurysm (20 mm). Nineteen medium-sized lesions were completely occluded during the angiographic follow-up (13 months). No cases of aneurysm rupture or retreatment were reported. No adverse events were described. Aneurysm occlusion was associated with the asymptomatic flow modification of the covered A1 that was occluded and contralaterally filled among 10 patients (50%), narrowed among 9 patients (45%), and unchanged in 1 subject (5%). There was no difference in the mean initial diameter of the occluded (2.1 [SD 0.4] mm; range, 1.6-3 mm) and narrowed (2 [SD, 0.2] mm; range, 1.7-2.6 mm) A1 segments. CONCLUSIONS: Medium-sized unruptured ICA bifurcation aneurysms with unfavorable morphology for coiling can be treated with M1 ICA flow diversion. Aneurysm occlusion is associated with flow modifications of the covered A1 that seems safe in the presence of a favorable collateral anatomy through the anterior communicating artery complex.


Asunto(s)
Aneurisma Roto , Embolización Terapéutica , Procedimientos Endovasculares , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Estudios Retrospectivos , Stents , Resultado del Tratamiento
5.
Clin Neurol Neurosurg ; 208: 106900, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34454205

RESUMEN

BACKGROUND & PURPOSE: The safety and efficacy of the Woven EndoBridge (WEB) device has been proven in recent multicenter trials. This study investigated whether operator experience influences WEB treatment-related outcomes. MATERIAL AND METHODS: This was a retrospective analysis of a prospectively collected multicenter database. The data of all patients who underwent WEB treatment for an intracranial aneurysm from March 2014 to June 2020 in two high-volume centers were pooled. Operator experience was indexed by the number of WEB treatments performed previously. The primary endpoint was the overall complication rate. Secondary endpoints were long-term adequate (Raymond-Roy classification of 1-2.) angiographic occlusion, WEB-related complications, number of WEB not deployed, procedure duration, and radiation exposure (air kerma). RESULTS: Among 237 patients (mean age 59.4 +/- 11.5 years) treated with WEB (median aneurysm diameter, 5.8 mm; interquartile range 4.5-7 mm), WEB-related complications occurred in 28 patients (11.8%) and adequate long-term occlusion was achieved for 154 aneurysms (86%). The median number of WEB treatment performed previously per operator was 20 (IQR, 9-41). The overall complication rate, WEB-related complication rate and aneurysm occlusion rate were not significantly correlated with WEB operator experience. There were also no significant correlations between the WEB operator experience and the number of WEB not deployed, procedure duration or radiation exposure. CONCLUSION: There was no significant association between the number of WEB treatments previously performed per operator and any technical or clinical results after intracranial aneurysm treatment with WEB. These results imply a relatively short learning curve for this device in high-volume neurovascular centers.


Asunto(s)
Competencia Clínica , Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal/terapia , Anciano , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
6.
AJNR Am J Neuroradiol ; 41(1): 134-139, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31924605

RESUMEN

BACKGROUND: Treatment management and outcomes of unruptured nonsaccular aneurysms are different compared with their saccular counterparts. PURPOSE: Our aim was to analyze the outcomes after flow diversion among nonsaccular unruptured lesions. DATA SOURCES: A systematic search of 3 data bases (2005-2019) was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. STUDY SELECTION: We included studies reporting flow diversion for nonsaccular unruptured aneurysms of the posterior and distal anterior circulations. Anterior circulation lesions were included if located distal to the petrocavernous and supraclinoid ICA (MCA, A1, anterior communicating artery, A2). Giant dolichoectatic holobasilar lesions were excluded because of their poor treatment outcomes. DATA ANALYSIS: Aneurysm occlusion and complication rates were calculated (random effects meta-analysis). DATA SYNTHESIS: We included 15 studies (213 aneurysms). The long-term adequate occlusion rate was 85.3% (137/168; 95% CI, 78.2%-92.4%; I2 = 42.3%). Treatment-related complications were 17.4% (41/213; 95% CI, 12.45%-22.4%; I2 = 0%). Overall, 15% (37/213; 95% CI, 10%-20%; I2 = 0%) were ischemic events. Procedure-related morbidity was 8% (20/213; 95% CI, 5%-12%; I2 = 0%). Fusiform or dissecting types had comparable adequate occlusion (116/146 = 83%; 95% CI, 74%-92%; I2 = 48% versus 33/36 = 89%; 95% CI, 80%-98%; I2 = 0%; P = .31) and complication rates (35/162 = 17%; 95% CI, 10%-25%; I2 = 24% versus 11/51 = 19%; 95% CI, 10%-31%; I2 = 0%; P = .72). Aneurysm size (>10 versus ≤10 mm) was independently associated with a higher rate of complications (OR = 6.6; 95% CI, 1.3-15; P = .02). The rate of ischemic events after discontinuation of the antiplatelet therapy was 5% (5/93; 95% CI, 2%-9%; I2 = 0%). LIMITATIONS: Small and retrospective studies were available for this meta-analysis. CONCLUSIONS: Unruptured nonsaccular aneurysms located in the posterior and distal anterior circulations can be effectively treated with flow diversion. Nevertheless, treatment-related complications are not negligible, with about 15% ischemic events and 8% morbidity. Larger size (>10 mm) significantly increases the risk of procedure-related adverse events.


Asunto(s)
Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Aneurisma Intracraneal/terapia , Adulto , Anciano , Bases de Datos Factuales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Stents , Resultado del Tratamiento
7.
Food Sci Technol Int ; 25(4): 303-317, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30646760

RESUMEN

Autochthonous lactic acid bacteria may provide a means of promoting the quality and safety of traditional fermented food products, in particular, artisanal cheeses. Pico cheese is an artisanal, dairy specialty of the Azores in risk of disappearing. Efforts to maintain its quality to the requirements of the modern markets are, thus, necessary. Lactic acid bacteria were isolated from artisanal Pico cheese, identified by sequencing of the 16S rRNA gene, and their potential as starter cultures was evaluated by studying their acidification ability, enzymatic activities (caseinolysis, lipolysis and API-ZYM profile), diacetyl and expolysaccharide production, autolysis, antimicrobial activity against Listeria monocytogenes ATCC 7466, Escherichia coli ATCC 25922, Staphylococcus aureus ATCC 29523, Pseudomonas aeruginosa ATCC 27853 and Clostridium perfringens ATCC 8357, sensory evaluation of odour formation in milk, syneresis and firmness of the curd. Several of the studied lactic acid bacteria isolates showed interesting properties for practical application as starters in artisanal cheese production. The isolates with the highest number of positive traits and, therefore, the most promising for starter development were Lactococcus lactis ssp. lactis L1C21M1, Lactobacillus paracasei L1B1E3, Leuconostoc pseudomesenteroides L1C1E6, Lactobacillus casei L1A1E5 and L1C1E8.


Asunto(s)
Queso/análisis , Queso/microbiología , Microbiología de Alimentos , Lactobacillales/fisiología , Animales , Antiinfecciosos , Fermentación , Lactobacillales/clasificación , Lactobacillales/aislamiento & purificación , Leche/microbiología , ARN Ribosómico 16S/genética
8.
AJNR Am J Neuroradiol ; 40(5): 820-826, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30975649

RESUMEN

BACKGROUND AND PURPOSE: The intrasaccular flow disruptor, the Woven EndoBridge device, is increasingly used for the treatment of wide-neck intracranial aneurysms. Due to unfavorable anatomy, additional stent placement is sometimes required to avoid Woven EndoBridge protrusion into bifurcation branches. We report our experience with the Woven EndoBridge associated with stent placement for the treatment of complex intracranial aneurysms. MATERIALS AND METHODS: Patients with aneurysms treated with the Woven EndoBridge Single-Layer plus stent placement were evaluated retrospectively with prospectively maintained data. The technical feasibility, procedural complications, aneurysm occlusion, and clinical outcome were studied. RESULTS: Seventeen patients and aneurysms treated with the Woven EndoBridge plus stent placement were included. The mean aneurysm size was 7 ± 3.1 mm. Aneurysm locations were the following: MCA (10 patients), anterior communicating artery (3 patients), basilar tip (3 patients), and posterior communicating artery (1 patient). Two lesions were ruptured and treated in the acute phase. The Woven EndoBridge and stent placement were successfully delivered in all cases. There were no permanent/major complications. Among the 2 patients with SAH, minor and completely reversible in-stent thrombosis occurred during treatment. An asymptomatic occlusion of the angular artery with a distal nonbifurcation aneurysm was discovered during the angiographic follow-up. Long-term (10.4 months) angiographic complete (Raymond-Roy I) and near-complete (Raymond-Roy II) occlusion was obtained in 11 (69%) and 2 (12.5%) aneurysms, respectively. The mean sizes of aneurysms showing Raymond-Roy I/Raymond-Roy II and Raymond-Roy III occlusion were 5.5 ± 2.1 mm and 10 ± 1 mm, respectively (P = .003). The mean fluoroscopy time was 35 ± 14 minutes. CONCLUSIONS: Aneurysm embolization with the Woven EndoBridge device associated with stent placement appears technically feasible and effective for the treatment of lesions with unfavorable anatomy. In our study, this strategy was relatively safe with a low rate of relevant procedure-related adverse events.


Asunto(s)
Prótesis Vascular , Embolización Terapéutica/instrumentación , Procedimientos Endovasculares/instrumentación , Aneurisma Intracraneal/terapia , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Stents , Resultado del Tratamiento
9.
AJNR Am J Neuroradiol ; 40(4): 687-693, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30872418

RESUMEN

BACKGROUND: The safety and efficacy of flow diversion among distal anterior circulation aneurysms must be proved. PURPOSE: Our aim was to analyze the outcomes after flow diversion among MCA, anterior communicating artery, and distal anterior cerebral artery aneurysms. DATA SOURCES: A systematic search of 3 databases was performed for studies published from 2005 to 2018. STUDY SELECTION: According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, we included studies reporting flow diversion of distal anterior circulation aneurysms. DATA ANALYSIS: Random-effects meta-analysis was used to pool aneurysm occlusion and complication rates. From the individual patient data, univariate and multivariate analyses were used to test predictors of occlusion and complications. DATA SYNTHESIS: We included 27 studies (484 aneurysms). The long-term adequate occlusion rate (O'Kelly-Marotta scale, C-D) was 82.7% (295/364; 95% CI, 77.4%-87.9%; I2 = 52%). Treatment-related complications were 12.5% (63/410; 95% CI, 9%-16%%; I2 = 18.8%), with 5.4% (29/418; 95% CI, 3.2%-7.5%; I2 = 0%) morbidity. MCA location was an independent factor associated with lower occlusion (OR = 0.5, P = .03) and higher complication rates (OR = 1.8, P = .02), compared with anterior communicating artery and distal anterior cerebral artery aneurysms. The Pipeline Embolization Device (versus other stents) gave better occlusion rates (OR = 2.6, P = .002), whereas large/giant aneurysms were associated with higher odds of complications (OR = 2.2, P = .03). The rates of occlusion and narrowing of arteries covered by flow-diverter stents were 6.3% (29/283; 95% CI, 3.5%-9.1%; I2 = 4.2%) and 23.8% (69/283; 95% CI, 15.7%-32%; I2 = 80%), respectively. Symptoms related to occlusion and narrowing of the jailed arteries were 3.5% (6/269; 95% CI, 1.1%-5%; I2 = 0%) and 3% (6/245; 95% CI, 1%-4%; I2 = 0%), respectively. LIMITATIONS: We reviewed small and retrospective series. CONCLUSIONS: Flow diversion among distal anterior circulation aneurysms is effective, leading to adequate aneurysm occlusion in 83% of cases. However, this strategy has some limitations among MCA and larger lesions, especially related to the higher rate of complications. Compared with the other devices, the Pipeline Embolization Device seems to be associated with a higher occlusion rate.


Asunto(s)
Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Aneurisma Intracraneal/cirugía , Stents , Adulto , Anciano , Embolización Terapéutica/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
10.
AJNR Am J Neuroradiol ; 40(4): 681-686, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30872419

RESUMEN

BACKGROUND: Clopidogrel is routinely used to decrease ischemic complications during neurointerventional procedures. However, the efficacy may be limited by antiplatelet resistance. PURPOSE: Our aim was to analyze the efficacy of prasugrel compared with clopidogrel in the cerebrovascular field. DATA SOURCES: A systematic search of 2 large databases was performed for studies published from 2000 to 2018. STUDY SELECTION: According to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, we included studies reporting treatment-related outcomes of patients undergoing neurointerventional procedures under prasugrel, and studies comparing prasugrel and clopidogrel. DATA ANALYSIS: Random-effects meta-analysis was used to pool the overall rate of complications, ischemic and hemorrhagic events, and influence of the dose of prasugrel. DATA SYNTHESIS: In the 7 included studies, 682 and 672 unruptured intracranial aneurysms were treated under prasugrel (cases) and clopidogrel (controls), respectively. Low-dose (20 mg/5 mg; loading and maintenance doses) prasugrel compared with the standard dose of clopidogrel (300 mg/75 mg) showed a significant reduction in the complication rate (OR = 0.36; 95% CI, 0.17-74, P = .006; I2 = 0%). Overall, the ischemic complication rate was significantly higher in the clopidogrel group (40/672 = 6%; 95% CI, 3%-13%; I2 = 83% versus 16/682 = 2%; 95% CI, 1%-5%; I2 = 73%; P = .03). Low and high loading doses of prasugrel were associated with 0.6% (5/535; 95% CI, 0.1%-1.6%; I2 = 0%) and 9.3% (13/147; 95% CI, 0.2%-18%; I2 = 60%) intraperiprocedural hemorrhages, respectively (P = .001), whereas low and high maintenance doses of prasugrel were associated with 0% (0/433) and 0.9% (2/249; 95% CI, 0.3%-2%; I2 = 0%) delayed hemorrhagic events, respectively (P = .001). LIMITATIONS: Retrospective series and heterogeneous endovascular treatments were limitations. CONCLUSIONS: In our study, low-dose prasugrel compared with clopidogrel premedication was associated with an effective reduction of the ischemic events with an acceptable rate of hemorrhagic complications.


Asunto(s)
Clopidogrel/uso terapéutico , Procedimientos Endovasculares/efectos adversos , Aneurisma Intracraneal/terapia , Inhibidores de Agregación Plaquetaria/uso terapéutico , Complicaciones Posoperatorias/prevención & control , Clorhidrato de Prasugrel/uso terapéutico , Anciano , Isquemia Encefálica/etiología , Isquemia Encefálica/prevención & control , Embolización Terapéutica/efectos adversos , Femenino , Hemorragia/epidemiología , Hemorragia/etiología , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Premedicación , Estudios Retrospectivos , Resultado del Tratamiento
11.
AJNR Am J Neuroradiol ; 40(7): 1201-1206, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31171518

RESUMEN

BACKGROUND AND PURPOSE: Delayed cerebral ischemia strongly impacts clinical outcome after aneurysmal SAH. The effect of antiplatelet therapy on delayed cerebral ischemia has been described with heterogeneous results. Our aim was to analyze the efficacy of antiplatelet therapy on delayed cerebral ischemia and clinical outcome in patients with SAH. DATA SOURCES: A systematic search of 3 databases was performed for studies published from 1990 to 2019. STUDY SELECTION: According to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, we included studies comparing the rates of delayed cerebral ischemia and clinical outcomes among patients with SAH with and without antiplatelet therapy. DATA ANALYSIS: Random-effects meta-analysis was used to pool the following: delayed cerebral ischemia, mortality, and good outcome rates. DATA SYNTHESIS: Including 7 studies, 1060 and 1762 patients with SAH were endovascularly or surgically treated with (cases) and without (controls) antiplatelet therapy, respectively. Overall, antiplatelet therapy did not significantly decrease delayed cerebral ischemia rates compared with the control group (219/1060 versus 485/1762, OR = 0.781; 95% CI, 0.46-1.31; P = .33). Among patients treated endovascularly, there was a trend toward lower delayed cerebral ischemia rates after antiplatelet therapy (157/778 versus 413/1410, OR = 0.552; 95% CI, 0.273-1.115; P = .06). Long-term (>2 weeks) antiplatelet therapy tended to be associated with a lower incidence of delayed cerebral ischemia (63/438 versus 96/353, OR = 0.379; 95% CI, 0.12-1.2; P = .06). The good-outcome rate was significantly higher (803/1144 versus 1175/1775, OR = 1.368; 95% CI, 1.117-1.676; P = .002) and the mortality rate was significantly lower (79/672 versus 97/571, OR = 0.656; 95% CI, 0.47-0.91; P = .01) among the antiplatelet therapy group. LIMITATIONS: Heterogeneity was high for most outcomes. CONCLUSIONS: Overall, the incidence of delayed cerebral ischemia seems not to be significantly reduced among the antiplatelet therapy group. However, delayed cerebral ischemia tended to be lower among subjects with both long-term antiplatelet therapy and endovascular treatment and antiplatelet administration. Poor outcome and mortality rates were significantly reduced among the antiplatelet therapy group.


Asunto(s)
Isquemia Encefálica/epidemiología , Isquemia Encefálica/etiología , Inhibidores de Agregación Plaquetaria/uso terapéutico , Hemorragia Subaracnoidea/complicaciones , Hemorragia Subaracnoidea/tratamiento farmacológico , Femenino , Humanos , Incidencia , Masculino , Resultado del Tratamiento
12.
AJNR Am J Neuroradiol ; 40(10): 1773-1778, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31537514

RESUMEN

BACKGROUND AND PURPOSE: Flow disruption with the Woven EndoBridge is increasingly used for the treatment of intracranial aneurysms. We examined factors leading to aneurysm occlusion and Woven EndoBridge shape change during a midterm follow-up. MATERIALS AND METHODS: Patients with a minimum 12-month angiographic follow-up were included. Through a univariate and multivariate analysis, independent predictors of adequate occlusion (Raymond-Roy 1/Raymond-Roy 2) and Woven EndoBridge shape change (decrease of the height of the device) were assessed. RESULTS: Eighty-six patients/aneurysms were included. The aneurysm mean size was 5.5 mm (range, 3-11.5 mm). The most common locations were the MCA (43/86 = 50%), basilar tip (13/86 = 15.1%), and anterior communicating artery (12/86 = 14%). Twenty-one patients (21/86 = 24%) had acute SAH. Immediate and long-term Raymond-Roy 1/Raymond-Roy 2 occlusion rates were 49% (42/86) and 80% (68/86), respectively. Woven EndoBridge shape change was detected among 22% (19/86) of cases. At binary logistic regression, wide ostium (≥4 mm) (OR = 0.2; 95% CI, 0.01-1; P = .04) and regular aneurysm morphology (OR = 5.9; 95% CI, 1.4-24; P = .01) were independent factors of incomplete and adequate aneurysm occlusion, respectively. In addition, irregular morphology (OR = 5.4; 95%CI, 1.4-19; P = .01) and a wide ostium (OR = 9.8; 95% CI, 1.6-60; P = .03) significantly increased the probability of the Woven EndoBridge shape change. Decrease of the Woven EndoBridge height was more common among incompletely occluded aneurysms (6/12 = 50% versus 13/74 = 17.5%), but it was not an independent prognosticator of occlusion at the multivariate model. CONCLUSIONS: The likelihood of good occlusion was 5 times lower in the presence of a wide ostium, whereas aneurysms with regular morphology were 6 times more likely to be occluded. Woven EndoBridge shape modification was strongly influenced by the aneurysm shape and ostium size, and it was not independently associated with the angiographic occlusion.


Asunto(s)
Embolización Terapéutica/instrumentación , Procedimientos Endovasculares/instrumentación , Aneurisma Intracraneal/patología , Aneurisma Intracraneal/terapia , Adulto , Anciano , Angiografía Cerebral , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
13.
AJNR Am J Neuroradiol ; 39(6): 1100-1106, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29650782

RESUMEN

BACKGROUND AND PURPOSE: Flow diversion for aneurysms beyond the circle of Willis is still debated. Our aim was to evaluate the safety and efficacy of flow diversion treatment of distal anterior cerebral artery aneurysms. MATERIALS AND METHODS: Consecutive patients with distal anterior cerebral artery aneurysms treated from January 2014 to October 2017 were evaluated retrospectively with prospectively maintained data. Treatment was performed only for unruptured or recanalized aneurysms after coiling. Technical feasibility, procedural complications, aneurysm occlusion (O'Kelly-Marotta grading scale), and clinical outcome were evaluated. RESULTS: Fifteen patients were included in the study, with 17 distal anterior cerebral artery saccular aneurysms treated with flow-diverter stents. Mean aneurysm size was 4.25 ± 3.9 mm; range, 2-9 mm. Flow diversion was used as retreatment among 6 previously coiled aneurysms (5 ruptured and coiled in the acute phase, and 1 unruptured and recanalized). Stent deployment was technically successful in all cases. During the perioperative period, 1 patient experienced a transient minor stroke (6%), whereas 2 patients reported acute in-stent thrombosis with disabling ischemic complications (13%). Fourteen patients and 16 aneurysms were available during a mean radiologic follow-up of 12 months (range, 3-24 months). Overall, 12 (75%) aneurysms were completely occluded (O'Kelly-Marotta grading scale score D), 1 aneurysm (6%) showed near-complete occlusion (O'Kelly-Marotta grading scale score C), and 3 aneurysms (19%) were incompletely occluded (O'Kelly-Marotta grading scale, score B). All 6 aneurysms previously coiled were completely occluded after flow diversion, whereas 70% of aneurysms treated with flow diverters alone showed complete/near-complete occlusion (O'Kelly-Marotta grading scale C-D). There were no cases of aneurysm rupture, in-stent occlusion, or retreatment during long-term follow-up. CONCLUSIONS: Treatment of distal anterior cerebral artery aneurysms with flow-diverter stents is feasible and effective, with high rates of aneurysm occlusion. Flow diversion plus coiling, in the retreatment of lesions previously coiled, allowed higher rates of occlusion compared with flow diverters alone. However, the risk of ischemic complications is not negligible, and flow-diversion treatment should be evaluated only for aneurysms not amenable to simple coil embolization.


Asunto(s)
Prótesis Vascular , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/métodos , Aneurisma Intracraneal/terapia , Stents , Adulto , Anciano , Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Stents/efectos adversos , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
14.
AJNR Am J Neuroradiol ; 39(11): 2057-2063, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30287459

RESUMEN

BACKGROUND AND PURPOSE: Flow diversion with intermediate-porosity stents (braided stents) has been recently reported for distally located small aneurysms. The aim of this study was to evaluate the flow-diversion effect of LEO stents on covered vessels and for aneurysms treated with sole stent-placement therapy. MATERIALS AND METHODS: We retrospectively evaluated the following outcomes: 1) remodeling of covered side branches and perforators (extra-aneurysmal flow remodeling), and 2) the occlusion rate of aneurysms treated with sole stent-placement therapy (intra-aneurysmal flow remodeling). RESULTS: Seventy-six patients with 98 covered vessels were studied. Overall, 89 covered arteries (91%) were normal, 7 showed narrowing (7%), and 2 (2%) were occluded (1 posterior communicating artery and 1 MCA) without related complications (mean DSA follow-up, 14 months). Univariate and multivariate analyses highlighted smoking (P = .03) and the length of follow-up (P = .002) as factors associated with arterial remodeling. Of the 17 Sylvian (lenticulostriate arteries) and 7 basilar perforators, 1 (4%) group of Sylvian perforators covered with double stents had asymptomatic remodeling. Ten aneurysms (mean size, 3.5 mm) were treated with LEO stents as stent monotherapy (5 recanalized after coiling and 5 directly treated with the LEO). Complete occlusion (Raymond-Roy I) was achieved in 70% of aneurysms (mean follow-up, 14 months). The Raymond-Roy I occlusion rate among recanalized aneurysms and those directly treated with LEO stents was 80% and 60%, respectively (P = .9). CONCLUSIONS: The rate of flow remodeling on the covered arteries and perforators was 9% and 4%, respectively, and was clinically irrelevant in all cases. Complete occlusion of aneurysms treated with sole stent-placement therapy was 70%. These data stress the flow-diversion properties of LEO stents.


Asunto(s)
Procedimientos Endovasculares/instrumentación , Aneurisma Intracraneal/cirugía , Stents , Remodelación Vascular , Adulto , Anciano , Femenino , Humanos , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
15.
AJNR Am J Neuroradiol ; 39(11): 2064-2069, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30262643

RESUMEN

BACKGROUND: The safety and efficacy of treatment with self-expandable braided stents (LEO and LVIS) required further investigation. PURPOSE: Our aim was to analyze the outcomes after treatment with braided stents. DATA SOURCES: A systematic search of 3 databases was performed for studies published from 2006 to 2017. STUDY SELECTION: According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, we included studies reporting patients treated with LEO or LVIS stents. DATA ANALYSIS: Random-effects meta-analysis was used to pool the following: aneurysm occlusion rate, complications, and neurologic outcomes. DATA SYNTHESIS: Thirty-five studies evaluating 1426 patients treated with braided stents were included in this meta-analysis. Successful stent delivery and complete aneurysm occlusion were 97% (1041/1095; 95% CI, 95%-98%) (I2 = 44%) and 88.3% (1097/1256; 95% CI, 85%-91%) (I2 = 72%), respectively. Overall, treatment-related complications were 7.4% (107/1317; 95% CI, 5%-9%) (I2 = 44%). Ischemic/thromboembolic events (48/1324 = 2.4%; 95% CI, 1.5%-3.4%) (I2 = 27%) and in-stent thrombosis (35/1324 = 1.5%; 95% CI, 0.6%-1.7%) (I2 = 0%) were the most common complications. Treatment-related morbidity was 1.5% (30/1324; 95% CI, 0.9%-2%) and was comparable between the LEO and LVIS groups. Complication rates between the anterior (29/322 = 8.8%; 95% CI, 3.4%-12%) (I2 = 41%) versus posterior circulation (10/84 = 10.5%; 95% CI, 4%-16%) (I2 = 0%) and distal (30/303 = 8%; 95% CI, 4.5%-12%) (I2 = 48%) versus proximal aneurysms (14/153 = 9%; 95% CI, 3%-13%) (I2 = 46%) were comparable (P > .05). LIMITATIONS: Limitations were selection and publication biases. CONCLUSIONS: In this analysis, treatment with the LEO and LVIS stents was relatively safe and effective. The most common complications were periprocedural thromboembolisms and in-stent thrombosis. The rate of complications was comparable among anterior and posterior circulation aneurysms, as well as for proximal and distally located lesions.


Asunto(s)
Procedimientos Endovasculares/instrumentación , Aneurisma Intracraneal/cirugía , Complicaciones Posoperatorias/epidemiología , Stents , Adulto , Bases de Datos Factuales , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Estudios Retrospectivos , Stents/efectos adversos , Tromboembolia/epidemiología , Tromboembolia/etiología , Resultado del Tratamiento
16.
AJNR Am J Neuroradiol ; 39(6): 1093-1099, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29700047

RESUMEN

BACKGROUND AND PURPOSE: Internal carotid dissection is a frequent cause of ischemic stroke in young adults. It may cause tandem occlusions in which cervical carotid obstruction is associated with intracranial proximal vessel occlusion. To date, no consensus has emerged concerning endovascular treatment strategy. Our aim was to evaluate our endovascular "distal-to-proximal" strategy in the treatment of this stroke subtype in the first large multicentric cohort. MATERIALS AND METHODS: Prospectively managed stroke data bases from 2 separate centers were retrospectively studied between 2009 and 2014 for records of tandem occlusions related to internal carotid dissection. Atheromatous tandem occlusions were excluded. The first step in the revascularization procedure was intracranial thrombectomy. Then, cervical carotid stent placement was performed depending on the functionality of the circle of Willis and the persistence of residual cervical ICA occlusion, severe stenosis, or thrombus apposition. Efficiency, complications, and radiologic and clinical outcomes were recorded. RESULTS: Thirty-four patients presenting with tandem occlusion stroke secondary to internal carotid dissection were treated during the study period. The mean age was 52.5 years, the mean initial NIHSS score was 17.29 ± 6.23, and the mean delay between onset and groin puncture was 3.58 ± 1.1 hours. Recanalization TICI 2b/3 was obtained in 21 cases (62%). Fifteen patients underwent cervical carotid stent placement. There was no recurrence of ipsilateral stroke in the nonstented subgroup. Twenty-one patients (67.65%) had a favorable clinical outcome after 3 months. CONCLUSIONS: Endovascular treatment of internal carotid dissection-related tandem occlusion stroke using the distal-to-proximal recanalization strategy appears to be feasible, with low complication rates and considerable rates of successful recanalization.


Asunto(s)
Revascularización Cerebral/métodos , Procedimientos Endovasculares/métodos , Accidente Cerebrovascular/cirugía , Adulto , Anciano , Arteriopatías Oclusivas/etiología , Arteriopatías Oclusivas/cirugía , Disección de la Arteria Carótida Interna/complicaciones , Bases de Datos Factuales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
17.
AJNR Am J Neuroradiol ; 39(5): 852-858, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29545248

RESUMEN

BACKGROUND: The safety and efficacy of reconstructive and deconstructive endovascular treatments of very large/giant intracranial aneurysms are not completely clear. PURPOSE: Our aim was to compare treatment-related outcomes between these 2 techniques. DATA SOURCES: A systematic search of 3 data bases was performed for studies published from 1990 to 2017. STUDY SELECTION: We selected series of reconstructive and deconstructive treatments with >10 patients. DATA ANALYSIS: Random-effects meta-analysis was used to analyze occlusion rates, complications, and neurologic outcomes. DATA SYNTHESIS: Thirty-nine studies evaluating 894 very large/giant aneurysms were included. Long-term occlusion of unruptured aneurysms was 71% and 93% after reconstructive and deconstructive treatments, respectively (P = .003). Among unruptured aneurysms, complications were lower after parent artery occlusion (16% versus 30%, P = .05), whereas among ruptured lesions, complications were lower after reconstructive techniques (34% versus 38%). Parent artery occlusion in the posterior circulation had higher complications compared with in the anterior circulation (36% versus 15%, P = .001). Overall, coiling yielded lower complication and occlusion rates compared with flow diverters and stent-assisted coiling. Complication rates of flow diversion were lower in the anterior circulation (17% versus 41%, P < .01). Among unruptured lesions, early aneurysm rupture (within 30 days) was slightly higher after reconstructive treatment (5% versus 0%, P = .08) and after flow diversion alone compared with flow diversion plus coiling (7% versus 0%). LIMITATIONS: Limitations were selection and publication biases. CONCLUSIONS: Parent artery occlusion allowed high rates of occlusion with an acceptable rate of complications for unruptured, anterior circulation aneurysms. Coiling should be preferred for posterior circulation and ruptured lesions, whereas flow diversion is relatively safe and effective for unruptured anterior circulation aneurysms.


Asunto(s)
Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Aneurisma Intracraneal/terapia , Procedimientos de Cirugía Plástica/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Stents , Resultado del Tratamiento
18.
AJNR Am J Neuroradiol ; 37(7): 1281-8, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26965467

RESUMEN

BACKGROUND AND PURPOSE: Internal carotid artery dissection is a common cause of stroke in young adults. It may be responsible for tandem occlusion defined by a cervical steno-occlusive carotid wall hematoma associated with an intracranial large-vessel stroke. Intravenous thrombolysis is associated with a poor clinical outcome in these cases, and endovascular treatment has not been specifically evaluated to date. Our aim was to evaluate endovascular treatment technical and clinical efficiency in this specific occlusion topography, in comparison with treatment of isolated anterior circulation stroke. MATERIALS AND METHODS: As part of our ongoing prospective stroke data base started in August 2009 (Prognostic Factors Related to Clinical Outcome Following Thrombectomy in Ischemic Stroke [RECOST] Study), we analyzed all carotid artery dissection tandem occlusion strokes and isolated anterior circulation occlusions. All patients were selected for endovascular treatment according to clinical-radiologic mismatch, NIHSS ≥ 7 and DWI-ASPECTS ≥5, within 6 hours after onset. For carotid artery dissection, the revascularization procedure consisted first of distal recanalization by a stent retriever in the intracranial vessel. Following assessment of the circle of Willis, internal carotid artery stent placement was only performed in case of insufficiency. Carotid artery dissection treatment efficacy, safety, and clinical outcome were compared with the results of the isolated anterior circulation occlusion cohort. RESULTS: Two hundred fifty-eight patients with an anterior circulation stroke were analyzed, including 57 with tandem occlusions (22%); among them, 20 were carotid artery dissection-related occlusions (7.6%). The median age of patients with tandem occlusions with internal carotid dissection was 52.45 versus 66.85 years for isolated anterior circulation occlusion (P < .05); the mean initial NIHSS score was 17.53 ± 4.11 versus 17.55 ± 4.8 (P = .983). The median DWI-ASPECTS was 6.05 versus 6.64 (P = .098), and the average time from onset to puncture was 4.38 for tandem occlusions versus 4.53 hours in isolated anterior circulation occlusion (P = .704). Complication rates and symptomatic intracranial hemorrhage were comparable in both groups (5% versus 3%, P = .49). The duration of the procedure was significantly prolonged in case of tandem occlusion (80.69 versus 65.45 minutes, P = .030). Fourteen patients with carotid artery dissection (70%) had a 3-month mRS of ≤ 2, without a significant difference from patients with an isolated anterior circulation occlusion (44%, P = .2). Only 5 carotid artery dissections (25%) necessitated cervical stent placement. No early ipsilateral stroke recurrence was recorded, despite the absence of stent placement in 15 patients (75%) with carotid artery dissection. CONCLUSIONS: Mechanical endovascular treatment of carotid artery dissection tandem occlusions is safe and effective compared with isolated anterior circulation occlusion stroke therapy. Hence, a more conservative approach with stent placement only in cases of circle of Willis insufficiency may be a reliable and safe strategy.


Asunto(s)
Disección de la Arteria Carótida Interna/complicaciones , Disección de la Arteria Carótida Interna/patología , Procedimientos Endovasculares/métodos , Accidente Cerebrovascular/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Arteria Carótida Interna/cirugía , Disección de la Arteria Carótida Interna/cirugía , Bases de Datos Factuales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Stents , Accidente Cerebrovascular/etiología , Trombectomía/métodos , Resultado del Tratamiento
19.
AJNR Am J Neuroradiol ; 36(4): 725-31, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25523592

RESUMEN

BACKGROUND AND PURPOSE: Flow-diverter technology has proved to be a safe and effective treatment for intracranial aneurysm based on the concept of flow diversion allowing parent artery and collateral preservation and aneurysm healing. We investigated the patency of covered side branches and flow modification within the parent artery following placement of the Pipeline Embolization Device in the treatment of intracranial aneurysms. MATERIALS AND METHODS: Sixty-six aneurysms in 59 patients were treated with 96 Pipeline Embolization Devices. We retrospectively reviewed imaging and clinical results during the postoperative period at 6 and 12 months to assess flow modification through the parent artery and side branches. Reperfusion syndrome was assessed by MR imaging and clinical evaluation. RESULTS: Slow flow was observed in 13 of 68 (19.1%) side branches covered by the Pipeline Embolization Device. It was reported in all cases of anterior cerebral artery coverage, in 3/5 cases of M2-MCA coverage, and in 5/34 (14.7%) cases of ophthalmic artery coverage. One territorial infarction was observed in a case of M2-MCA coverage, without arterial occlusion. One case of deep Sylvian infarct was reported in a case of coverage of MCA perforators. Two ophthalmic arteries (5.9%) were occluded, and 11 side branches (16.2%) were narrowed at 12 months' follow-up; patients remained asymptomatic. Parent vessel flow modification was responsible for 2 cases (3.4%) of reperfusion syndrome. Overall permanent morbidity and mortality rates were 5.2% and 6.9%, respectively. We did not report any permanent deficit or death in case of slow flow observed within side branches. CONCLUSIONS: After Pipeline Embolization Device placement, reperfusion syndrome was observed in 3.4%, and territorial infarction, in 3.4%. Delayed occlusion of ophthalmic arteries and delayed narrowing of arteries covered by the Pipeline Embolization Device were observed in 5.9% and 16.2%, respectively. No permanent morbidity or death was related to side branch coverage at midterm follow-up.


Asunto(s)
Embolización Terapéutica/efectos adversos , Aneurisma Intracraneal/cirugía , Daño por Reperfusión/epidemiología , Adulto , Anciano , Embolización Terapéutica/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
20.
AJNR Am J Neuroradiol ; 36(11): 2096-103, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26272976

RESUMEN

BACKGROUND AND PURPOSE: We report our preliminary results in terms of safety and efficacy in using the low-profile LEO Baby stent for the treatment of large-neck and complex intracranial aneurysms with balloon-then-stent-assisted coiling and single- or dual-stent-assisted coiling. MATERIALS AND METHODS: Clinical and radiologic data of all consecutive patients treated at our institution from September 2012 to October 2013 for an intracranial aneurysm by using a LEO Baby stent were retrospectively analyzed. Immediate and midterm clinical and anatomic follow-up of each patient is reported. RESULTS: Twenty-nine patients with 29 aneurysms were treated with LEO Baby stents at our institution. The mean age of patients was 48 years; 20 patients were women (71%). One patient was treated in the acute phase of a subarachnoid hemorrhage. In 8 procedures, a double-lumen-catheter balloon was used for balloon-then-stent-assisted coiling. In 3 cases, a LEO Baby stent was used in a Y-, T-, and telescopic dual-stent configuration. In 18 cases, a single LEO Baby stent was used. In 2 cases, technical failure to deploy the stent resulted in acute parent artery thrombosis. In 3 further cases, thromboembolic complications occurred intraoperatively. MR imaging and angiographic midterm follow-up showed complete aneurysm occlusion for 96% of the followed patients (27/29). Clinical outcome was favorable for all patients followed up. CONCLUSIONS: Results obtained in our study by using the LEO Baby stent for balloon-then-stent and single- or dual-stent-assisted coiling of complex and distally located intracranial aneurysms are encouraging. Incomplete or inadequate opening of the device is a potential cause of laminar blood flow alteration and thrombus formation.


Asunto(s)
Implantación de Prótesis Vascular/métodos , Embolización Terapéutica/instrumentación , Aneurisma Intracraneal/cirugía , Stents , Adulto , Anciano , Anciano de 80 o más Años , Implantación de Prótesis Vascular/efectos adversos , Embolización Terapéutica/efectos adversos , Femenino , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Radiografía , Estudios Retrospectivos , Stents/efectos adversos , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA