RESUMEN
An SU-8 probe with an array of nine, individually addressable gold microband electrodes (100 µm long, 4 µm wide, separated by 4-µm gaps) was photolithographically fabricated and characterized for detection of low concentrations of chemicals in confined spaces and in vivo studies of biological tissues. The probe's shank (6 mm long, 100 µm wide, 100 µm thick) is flexible, but exhibits sufficient sharpness and rigidity to be inserted into soft tissue. Laser micromachining was used to define probe geometry by spatially revealing the underlying sacrificial aluminum layer, which was then etched to free the probes from a silicon wafer. Perfusion with fluorescent nanobeads showed that, like a carbon fiber electrode, the probe produced no noticeable damage when inserted into rat brain, in contrast to damage from an inserted microdialysis probe. The individual addressability of the electrodes allows single and multiple electrode activation. Redox cycling is possible, where adjacent electrodes serve as generators (that oxidize or reduce molecules) and collectors (that do the opposite) to amplify signals of small concentrations without background subtraction. Information about electrochemical mechanisms and kinetics may also be obtained. Detection limits for potassium ferricyanide in potassium chloride electrolyte of 2.19, 1.25, and 2.08 µM and for dopamine in artificial cerebral spinal fluid of 1.94, 1.08, and 5.66 µM for generators alone and for generators and collectors during redox cycling, respectively, were obtained.
Asunto(s)
Dopamina/líquido cefalorraquídeo , Técnicas Electroquímicas/instrumentación , Microelectrodos , Animales , Calibración , Cuerpo Estriado/cirugía , Técnicas Electroquímicas/métodos , Electrólitos/química , Ferricianuros/análisis , Ferricianuros/química , Oro , Rayos Láser , Masculino , Microelectrodos/efectos adversos , Microtecnología , Oxidación-Reducción , Polímeros/química , Cloruro de Potasio/química , Ratas Sprague-DawleyRESUMEN
Vascular damage and reduced tissue perfusion are expected to majorly contribute to the loss of neurons or neural signals around implanted electrodes. However, there are limited methods of controlling the vascular dynamics in tissues surrounding these implants. This work utilizes conducting polymer poly(ethylenedioxythiophene) and sulfonated silica nanoparticle composite (PEDOT/SNP) to load and release a vasodilator, sodium nitroprusside, to controllably dilate the vasculature around carbon fiber electrodes (CFEs) implanted in the mouse cortex. The vasodilator release is triggered via electrical stimulation and the amount of release increases with increasing electrical pulses. The vascular dynamics are monitored in real-time using two-photon microscopy, with changes in vessel diameters quantified before, during, and after the release of the vasodilator into the tissues. This work observes significant increases in vessel diameters when the vasodilator is electrically triggered to release, and differential effects of the drug release on vessels of different sizes. In conclusion, the use of nanoparticle reservoirs in conducting polymer-based drug delivery platforms enables the controlled delivery of vasodilator into the implant environment, effectively altering the local vascular dynamics on demand. With further optimization, this technology could be a powerful tool to improve the neural electrode-tissue interface and study neurovascular coupling.
Asunto(s)
Nanopartículas , Vasodilatadores , Ratones , Animales , Dióxido de Silicio , Polímeros/farmacología , Electrodos Implantados , Encéfalo/fisiología , Compuestos Bicíclicos Heterocíclicos con Puentes/farmacologíaRESUMEN
In vivo glutamate sensing has provided valuable insight into the physiology and pathology of the brain. Electrochemical glutamate biosensors, constructed by cross-linking glutamate oxidase onto an electrode and oxidizing H2O2 as a proxy for glutamate, are the gold standard for in vivo glutamate measurements for many applications. While glutamate sensors have been employed ubiquitously for acute measurements, there are almost no reports of long-term, chronic glutamate sensing in vivo, despite demonstrations of glutamate sensors lasting for weeks in vitro. To address this, we utilized a platinum electrode with nanometer-scale roughness (nanoPt) to improve the glutamate sensors' sensitivity and longevity. NanoPt improved the GLU sensitivity by 67.4% and the sensors were stable in vitro for 3 weeks. In vivo, nanoPt glutamate sensors had a measurable signal above a control electrode on the same array for 7 days. We demonstrate the utility of the nanoPt sensors by studying the effect of traumatic brain injury on glutamate in the rat striatum with a flexible electrode array and report measurements of glutamate taken during the injury itself. We also show the flexibility of the nanoPt platform to be applied to other oxidase enzyme-based biosensors by measuring γ-aminobutyric acid in the porcine spinal cord. NanoPt is a simple, effective way to build high sensitivity, robust biosensors harnessing enzymes to detect neurotransmitters in vivo.
Asunto(s)
Aminoácido Oxidorreductasas , Técnicas Biosensibles , Ácido Glutámico , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Animales , Ácido Glutámico/análisis , Ácido Glutámico/química , Ratas , Aminoácido Oxidorreductasas/química , Aminoácido Oxidorreductasas/metabolismo , Electrodos , Platino (Metal)/química , Porcinos , Lesiones Traumáticas del Encéfalo/metabolismo , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Peróxido de Hidrógeno/análisis , Peróxido de Hidrógeno/metabolismo , Peróxido de Hidrógeno/química , Ratas Sprague-Dawley , Masculino , GalvanoplastiaRESUMEN
Traumatic brain injury (TBI) is a major public health crisis in many regions of the world. Severe TBI may cause a primary brain lesion with a surrounding penumbra of tissue that is vulnerable to secondary injury. Secondary injury presents as progressive expansion of the lesion, possibly leading to severe disability, a persistent vegetive state, or death. Real time neuromonitoring to detect and monitor secondary injury is urgently needed. Dexamethasone-enhanced continuous online microdialysis (Dex-enhanced coMD) is an emerging paradigm for chronic neuromonitoring after brain injury. The present study employed Dex-enhanced coMD to monitor brain K+ and O2 during manually induced spreading depolarization in the cortex of anesthetized rats and after controlled cortical impact, a widely used rodent model of TBI, in behaving rats. Consistent with prior reports on glucose, O2 exhibited a variety of responses to spreading depolarization and a prolonged, essentially permanent decline in the days after controlled cortical impact. These findings confirm that Dex-enhanced coMD delivers valuable information regarding the impact of spreading depolarization and controlled cortical impact on O2 levels in the rat cortex.
Asunto(s)
Lesiones Traumáticas del Encéfalo , Lesiones Encefálicas , Ratas , Animales , Microdiálisis , Lesiones Encefálicas/patología , Encéfalo , Dexametasona/farmacologíaRESUMEN
Chronic sampling of tonic serotonin (5-hydroxytryptamine, 5-HT) concentrations in the brain is critical for tracking neurological disease development and the time course of pharmacological treatments. Despite their value, in vivo chronic multi-site measurements of tonic 5-HT have not been reported. To fill this technological gap, we batch-fabricated implantable glassy carbon (GC) microelectrode arrays (MEAs) onto a flexible SU-8 substrate to provide an electrochemically stable and biocompatible device/tissue interface. To achieve detection of tonic 5-HT concentrations, we applied a poly(3,4-ethylenedioxythiophene)/carbon nanotube (PEDOT/CNT) electrode coating and optimized a square wave voltammetry (SWV) waveform for selective 5-HT measurement. In vitro, the PEDOT/CNT-coated GC microelectrodes achieved high sensitivity to 5-HT, good fouling resistance, and excellent selectivity against the most common neurochemical interferents. In vivo, our PEDOT/CNT-coated GC MEAs successfully detected basal 5-HT concentrations at different locations within the CA2 region of the hippocampus of both anesthetized and awake mice. Furthermore, the PEDOT/CNT-coated MEAs were able to detect tonic 5-HT in the mouse hippocampus for one week after implantation. Histology reveals that the flexible GC MEA implants caused less tissue damage and reduced inflammatory response in the hippocampus compared to commercially available stiff silicon probes. To the best of our knowledge, this PEDOT/CNT-coated GC MEA is the first implantable, flexible sensor capable of chronic in vivo multi-site sensing of tonic 5-HT.
Asunto(s)
Técnicas Biosensibles , Serotonina , Ratones , Animales , Microelectrodos , Polímeros/farmacología , Compuestos Bicíclicos Heterocíclicos con PuentesRESUMEN
Real-time multi-channel measurements of tonic serotonin (5-hydroxytryptamine, 5-HT) concentrations across different brain regions are of utmost importance to the understanding of 5-HTâ™s role in anxiety, depression, and impulse control disorders, which will improve the diagnosis and treatment of these neuropsychiatric illnesses. Chronic sampling of 5-HT is critical in tracking disease development as well as the time course of pharmacological treatments. Despite their value, in vivo chronic multi-site measurements of 5-HT have not been reported. To fill this technological gap, we batch fabricated implantable glassy carbon (GC) microelectrode arrays (MEAs) on a flexible SU-8 substrate to provide an electrochemically stable and biocompatible device/tissue interface. Then, to achieve multi-site detection of tonic 5-HT concentrations, we incorporated the poly(3,4-ethylenedioxythiophene)/functionalized carbon nanotube (PEDOT/CNT) coating on the GC microelectrodes in combination with a new square wave voltammetry (SWV) approach, optimized for selective 5-HT measurement. In vitro , the PEDOT/CNT coated GC microelectrodes achieved high sensitivity towards 5-HT, good fouling resistance in the presence of 5-HT, and excellent selectivity towards the most common neurochemical interferents. In vivo , our PEDOT/CNT-coated GC MEAs were able to successfully detect basal 5-HT concentrations at different locations of the CA2 hippocampal region of mice in both anesthetized and awake head-fixed conditions. Furthermore, the implanted PEDOT/CNT-coated MEA achieved stable detection of tonic 5-HT concentrations for one week. Finally, histology data in the hippocampus shows reduced tissue damage and inflammatory responses compared to stiff silicon probes. To the best of our knowledge, this PEDOT/CNT-coated GC MEA is the first implantable flexible multisite sensor capable of chronic in vivo multi-site sensing of tonic 5-HT. This implantable MEA can be custom-designed according to specific brain region of interests and research questions, with the potential to combine electrophysiology recording and multiple analyte sensing to maximize our understanding of neurochemistry. Highlights: PEDOT/CNT-coated GC microelectrodes enabled sensitive and selective tonic detection of serotonin (5-HT) using a new square wave voltammetry (SWV) approach PEDOT/CNT-coated GC MEAs achieved multi-site in vivo 5-HT tonic detection for one week. Flexible MEAs lead to reduced tissue damage and inflammation compared to stiff silicon probes.
RESUMEN
Dopamine (DA) plays a central role in the modulation of various physiological brain functions, including learning, motivation, reward, and movement control. The DA dynamic occurs over multiple timescales, including fast phasic release, as a result of neuronal firing and slow tonic release, which regulates the phasic firing. Real-time measurements of tonic and phasic DA concentrations in the living brain can shed light on the mechanism of DA dynamics underlying behavioral and psychiatric disorders and on the action of pharmacological treatments targeting DA. Current state-of-the-art in vivo DA detection technologies are limited in either spatial or temporal resolution, channel count, longitudinal stability, and ability to measure both phasic and tonic dynamics. We present here an implantable glassy carbon (GC) multielectrode array on a SU-8 flexible substrate for integrated multichannel phasic and tonic measurements of DA concentrations. The GC MEA demonstrated in vivo multichannel fast-scan cyclic voltammetry (FSCV) detection of electrically stimulated phasic DA release simultaneously at different locations of the mouse dorsal striatum. Tonic DA measurement was enabled by coating GC electrodes with poly(3,4-ethylenedioxythiophene)/carbon nanotube (PEDOT/CNT) and using optimized square-wave voltammetry (SWV). Implanted PEDOT/CNT-coated MEAs achieved stable detection of tonic DA concentrations for up to 3 weeks in the mouse dorsal striatum. This is the first demonstration of implantable flexible MEA capable of multisite electrochemical sensing of both tonic and phasic DA dynamics in vivo with chronic stability.
Asunto(s)
Dopamina , Nanotubos de Carbono , Animales , Encéfalo , Cuerpo Estriado , Humanos , RatonesRESUMEN
The brain is a complex network that accounts for only 5% of human mass but consumes 20% of our energy. Uncovering the mysteries of the brain's functions in motion, memory, learning, behavior, and mental health remains a hot but challenging topic. Neurochemicals in the brain, such as neurotransmitters, neuromodulators, gliotransmitters, hormones, and metabolism substrates and products, play vital roles in mediating and modulating normal brain function, and their abnormal release or imbalanced concentrations can cause various diseases, such as epilepsy, Alzheimer's disease, and Parkinson's disease. A wide range of techniques have been used to probe the concentrations of neurochemicals under normal, stimulated, diseased, and drug-induced conditions in order to understand the neurochemistry of drug mechanisms and develop diagnostic tools or therapies. Recent advancements in detection methods, device fabrication, and new materials have resulted in the development of neurochemical sensors with improved performance. However, direct in vivo measurements require a robust sensor that is highly sensitive and selective with minimal fouling and reduced inflammatory foreign body responses. Here, we review recent advances in neurochemical sensor development for in vivo studies, with a focus on electrochemical and optical probes. Other alternative methods are also compared. We discuss in detail the in vivo challenges for these methods and provide an outlook for future directions.
RESUMEN
Traumatic brain injury (TBI) induces a pathophysiologic state that can be worsened by secondary injury. Monitoring brain metabolism with intracranial microdialysis can provide clinical insights to limit secondary injury in the days following TBI. Recent enhancements to microdialysis include the implementation of continuously operating electrochemical biosensors for monitoring the dialysate sample stream in real time and dexamethasone retrodialysis to mitigate the tissue response to probe insertion. Dexamethasone-enhanced continuous-online microdialysis (Dex-enhanced coMD) records long-lasting declines of glucose after controlled cortical impact in rats and TBI in patients. The present study employed retrodialysis and fluorescence microscopy to investigate the mechanism responsible for the decline of dialysate glucose after injury of the rat cortex. Findings confirm the long-term functionality of Dex-enhanced coMD for monitoring brain glucose after injury, demonstrate that intracranial glucose microdialysis is coupled to glucose utilization in the tissues surrounding the probes, and validate the conclusion that aberrant glucose utilization drives the postinjury glucose decline.
Asunto(s)
Lesiones Encefálicas , Animales , Encéfalo , Dexametasona , Glucosa , Humanos , Microdiálisis , RatasRESUMEN
Melatonin (MT) has been recently considered an excellent candidate for the treatment of sleep disorders, neural injuries, and neurological diseases. To better investigate the actions of MT in various brain functions, real-time detection of MT concentrations in specific brain regions is much desired. Previously, we have demonstrated detection of exogenously administered MT in anesthetized mouse brain using square wave voltammetry (SWV). Here, for the first time, we show successful detection of exogenous MT in the brain using fast scan cyclic voltammetry (FSCV) on electrochemically pre-activated carbon fiber microelectrodes (CFEs). In vitro evaluation showed the highest sensitivity (28.1 nA/µM) and lowest detection limit (20.2 ± 4.8 nM) ever reported for MT detection at carbon surface. Additionally, an extensive CFE stability and fouling assessment demonstrated that a prolonged CFE pre-conditioning stabilizes the background, in vitro and in vivo, and provides consistent CFE sensitivity over time even in the presence of a high MT concentration. Finally, the stable in vivo background, with minimized CFE fouling, allows us to achieve a drift-free FSCV detection of exogenous administered MT in mouse brain over a period of 3 min, which is significantly longer than the duration limit (usually < 90 s) for traditional in vivo FSCV acquisition. The MT concentration and dynamics measured by FSCV are in good agreement with SWV, while microdialysis further validated the concentration range. These results demonstrated reliable MT detection using FSCV that has the potential to monitor MT in the brain over long periods of time.
RESUMEN
Intracerebral microdialysis has proven useful for chemical monitoring in patients following traumatic brain injury. Recent studies in animals, however, have documented that insertion of microdialysis probes into brain tissues initiates a foreign-body response. Within a few days after probe insertion, the foreign body response impedes the use of microdialysis to monitor the K+ and glucose transients associated with spreading depolarization, a potential mechanism for secondary brain injury. Herein, we show that perfusing microdialysis probes with dexamethasone, a potent anti-inflammatory glucocorticoid, suppresses the foreign body response and facilitates the monitoring of spontaneous spreading depolarizations for at least 10 days following controlled cortical injury in the rat. In addition to spreading depolarizations, results of this study suggest that a progressive, apparently permanent, decline in pericontusional interstitial glucose may be an additional sequela of brain injury. This study establishes extended dexamethasone-enhanced microdialysis in the injured rodent cortex as a new paradigm for investigating trauma-induced metabolic crisis.
Asunto(s)
Antiinflamatorios/uso terapéutico , Lesiones Encefálicas/metabolismo , Encéfalo/efectos de los fármacos , Dexametasona/uso terapéutico , Reacción a Cuerpo Extraño/prevención & control , Microdiálisis/métodos , Animales , Antiinflamatorios/farmacología , Encéfalo/metabolismo , Dexametasona/farmacología , Glucosa/metabolismo , Masculino , Monitoreo Fisiológico , Potasio/metabolismo , Ratas , Ratas Sprague-DawleyRESUMEN
Dopamine (DA) is a monoamine neurotransmitter responsible for regulating a variety of vital life functions. In vivo detection of DA poses a challenge due to the low concentration and high speed of physiological signaling. Fast scan cyclic voltammetry at carbon fiber microelectrodes (CFEs) is an effective method to monitor real-time in vivo DA signaling, however the sensitivity is somewhat limited. Electrodeposition of poly(3,4-ethylene dioxythiophene) (PEDOT)/graphene oxide (GO) onto the CFE surface is shown to increase the sensitivity and lower the limit of detection for DA compared to bare CFEs. Thicker PEDOT/GO coatings demonstrate higher sensitivities for DA, but display the negative drawback of slow adsorption and electron transfer kinetics. The moderate thickness resulting from 25 s electrodeposition of PEDOT/GO produces the optimal electrode, exhibiting an 880% increase in sensitivity, a 50% decrease in limit of detection and minimally altered electrode kinetics. PEDOT/GO coated electrodes rapidly and robustly detect DA, both in solution and in the rat dorsal striatum. This increase in DA sensitivity is likely due to increasing the electrode surface area with a PEDOT/GO coating and improved adsorption of DA's oxidation product (DA-o-quinone). Increasing DA sensitivity without compromising electrode kinetics is expected to significantly improve our understanding of the DA function in vivo.
Asunto(s)
Compuestos Bicíclicos Heterocíclicos con Puentes/química , Cuerpo Estriado/química , Dopamina/análisis , Técnicas Electroquímicas/métodos , Grafito/química , Polímeros/química , Animales , Técnicas Biosensibles/métodos , Galvanoplastia , Límite de Detección , Masculino , Microelectrodos , Ratas , Ratas Sprague-DawleyRESUMEN
In vivo voltammetry reveals substantial diversity of dopamine kinetics in the rat striatum. To substantiate this kinetic diversity, we evaluate the temporal distortion of dopamine measurements arising from the diffusion-limited adsorption of dopamine to voltammetric microelectrodes. We validate two mathematical procedures for correcting adsorptive distortion, both of which substantiate that dopamine's apparent kinetic diversity is not an adsorption artifact.
Asunto(s)
Cuerpo Estriado/metabolismo , Dopamina/metabolismo , Técnicas Electroquímicas/métodos , Profármacos/farmacocinética , Animales , Masculino , Farmacocinética , Ratas , Ratas Sprague-DawleyRESUMEN
Dopamine is an important neurotransmitter that exhibits numerous functions in the healthy, injured, and diseased brain. Fast scan cyclic voltammetry paired with electrical stimulation of dopamine axons is a popular and powerful method for investigating the dynamics of dopamine in the extracellular space. Evidence now suggests that the heterogeneity of electrically evoked dopamine responses reflects the inherent kinetic diversity of dopamine systems, which might contribute to their diversity of physiological function. Dopamine measurements by fast scan cyclic voltammetry are affected by the adsorption of dopamine to carbon fiber electrodes. The temporal distortion caused by dopamine adsorption is correctable by a straightforward mathematical procedure. The corrected responses exhibit excellent agreement with a dopamine kinetic model cast to provide a generic description of restricted diffusion, short-term plasticity of dopamine release, and first-order dopamine clearance. The new DA kinetic model brings to light the rich kinetic information content of electrically evoked dopamine responses recorded via fast scan cyclic voltammetry in the rat dorsal striatum.