Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 411
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Nature ; 613(7943): 383-390, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36599982

RESUMEN

Specific, regulated modification of RNAs is important for proper gene expression1,2. tRNAs are rich with various chemical modifications that affect their stability and function3,4. 7-Methylguanosine (m7G) at tRNA position 46 is a conserved modification that modulates steady-state tRNA levels to affect cell growth5,6. The METTL1-WDR4 complex generates m7G46 in humans, and dysregulation of METTL1-WDR4 has been linked to brain malformation and multiple cancers7-22. Here we show how METTL1 and WDR4 cooperate to recognize RNA substrates and catalyse methylation. A crystal structure of METTL1-WDR4 and cryo-electron microscopy structures of METTL1-WDR4-tRNA show that the composite protein surface recognizes the tRNA elbow through shape complementarity. The cryo-electron microscopy structures of METTL1-WDR4-tRNA with S-adenosylmethionine or S-adenosylhomocysteine along with METTL1 crystal structures provide additional insights into the catalytic mechanism by revealing the active site in multiple states. The METTL1 N terminus couples cofactor binding with conformational changes in the tRNA, the catalytic loop and the WDR4 C terminus, acting as the switch to activate m7G methylation. Thus, our structural models explain how post-translational modifications of the METTL1 N terminus can regulate methylation. Together, our work elucidates the core and regulatory mechanisms underlying m7G modification by METTL1, providing the framework to understand its contribution to biology and disease.


Asunto(s)
Microscopía por Crioelectrón , Proteínas de Unión al GTP , Metilación , Metiltransferasas , Procesamiento Postranscripcional del ARN , ARN de Transferencia , Humanos , Dominio Catalítico , Cristalografía por Rayos X , Proteínas de Unión al GTP/química , Proteínas de Unión al GTP/metabolismo , Proteínas de Unión al GTP/ultraestructura , Metiltransferasas/química , Metiltransferasas/metabolismo , Metiltransferasas/ultraestructura , ARN de Transferencia/química , ARN de Transferencia/metabolismo , ARN de Transferencia/ultraestructura , S-Adenosilhomocisteína/metabolismo , S-Adenosilmetionina/metabolismo , Especificidad por Sustrato , Biocatálisis
2.
N Engl J Med ; 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38767244

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

3.
N Engl J Med ; 386(11): 1046-1057, 2022 03 17.
Artículo en Inglés | MEDLINE | ID: mdl-35081293

RESUMEN

BACKGROUND: Although the three vaccines against coronavirus disease 2019 (Covid-19) that have received emergency use authorization in the United States are highly effective, breakthrough infections are occurring. Data are needed on the serial use of homologous boosters (same as the primary vaccine) and heterologous boosters (different from the primary vaccine) in fully vaccinated recipients. METHODS: In this phase 1-2, open-label clinical trial conducted at 10 sites in the United States, adults who had completed a Covid-19 vaccine regimen at least 12 weeks earlier and had no reported history of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection received a booster injection with one of three vaccines: mRNA-1273 (Moderna) at a dose of 100 µg, Ad26.COV2.S (Johnson & Johnson-Janssen) at a dose of 5×1010 virus particles, or BNT162b2 (Pfizer-BioNTech) at a dose of 30 µg. The primary end points were safety, reactogenicity, and humoral immunogenicity on trial days 15 and 29. RESULTS: Of the 458 participants who were enrolled in the trial, 154 received mRNA-1273, 150 received Ad26.COV2.S, and 153 received BNT162b2 as booster vaccines; 1 participant did not receive the assigned vaccine. Reactogenicity was similar to that reported for the primary series. More than half the recipients reported having injection-site pain, malaise, headache, or myalgia. For all combinations, antibody neutralizing titers against a SARS-CoV-2 D614G pseudovirus increased by a factor of 4 to 73, and binding titers increased by a factor of 5 to 55. Homologous boosters increased neutralizing antibody titers by a factor of 4 to 20, whereas heterologous boosters increased titers by a factor of 6 to 73. Spike-specific T-cell responses increased in all but the homologous Ad26.COV2.S-boosted subgroup. CD8+ T-cell levels were more durable in the Ad26.COV2.S-primed recipients, and heterologous boosting with the Ad26.COV2.S vaccine substantially increased spike-specific CD8+ T cells in the mRNA vaccine recipients. CONCLUSIONS: Homologous and heterologous booster vaccines had an acceptable safety profile and were immunogenic in adults who had completed a primary Covid-19 vaccine regimen at least 12 weeks earlier. (Funded by the National Institute of Allergy and Infectious Diseases; DMID 21-0012 ClinicalTrials.gov number, NCT04889209.).


Asunto(s)
Vacuna nCoV-2019 mRNA-1273/inmunología , Ad26COVS1/inmunología , Anticuerpos Neutralizantes/sangre , Anticuerpos Antivirales/sangre , Vacuna BNT162/inmunología , Vacunas contra la COVID-19/inmunología , Inmunogenicidad Vacunal , Adulto , Anciano , Anciano de 80 o más Años , Vacunas contra la COVID-19/efectos adversos , Femenino , Humanos , Inmunización Secundaria/efectos adversos , Inyecciones Intramusculares/efectos adversos , Masculino , Persona de Mediana Edad , SARS-CoV-2/inmunología , Glicoproteína de la Espiga del Coronavirus/inmunología , Linfocitos T/inmunología
4.
Eur Heart J ; 45(14): 1241-1251, 2024 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-38426911

RESUMEN

BACKGROUND AND AIMS: Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. METHODS: All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine-Gray competing risk models. RESULTS: 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6-64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%-5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36-.61; P < .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%-6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P < .001). CONCLUSIONS: Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.


Asunto(s)
Arritmias Cardíacas , Marcapaso Artificial , Humanos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Resultado del Tratamiento , Diseño de Equipo , Marcapaso Artificial/efectos adversos , Sistema de Registros , Estimulación Cardíaca Artificial/efectos adversos
5.
Clin Infect Dis ; 78(6): 1757-1768, 2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38537255

RESUMEN

INTRODUCTION: A surge of human influenza A(H7N9) cases began in 2016 in China from an antigenically distinct lineage. Data are needed about the safety and immunogenicity of 2013 and 2017 A(H7N9) inactivated influenza vaccines (IIVs) and the effects of AS03 adjuvant, prime-boost interval, and priming effects of 2013 and 2017 A(H7N9) IIVs. METHODS: Healthy adults (n = 180), ages 19-50 years, were enrolled into this partially blinded, randomized, multicenter phase 2 clinical trial. Participants were randomly assigned to 1 of 6 vaccination groups evaluating homologous versus heterologous prime-boost strategies with 2 different boost intervals (21 vs 120 days) and 2 dosages (3.75 or 15 µg of hemagglutinin) administered with or without AS03 adjuvant. Reactogenicity, safety, and immunogenicity measured by hemagglutination inhibition and neutralizing antibody titers were assessed. RESULTS: Two doses of A(H7N9) IIV were well tolerated, and no safety issues were identified. Although most participants had injection site and systemic reactogenicity, these symptoms were mostly mild to moderate in severity; injection site reactogenicity was greater in vaccination groups receiving adjuvant. Immune responses were greater after an adjuvanted second dose, and with a longer interval between prime and boost. The highest hemagglutination inhibition geometric mean titer (95% confidence interval) observed against the 2017 A(H7N9) strain was 133.4 (83.6-212.6) among participants who received homologous, adjuvanted 3.75 µg + AS03/2017 doses with delayed boost interval. CONCLUSIONS: Administering AS03 adjuvant with the second H7N9 IIV dose and extending the boost interval to 4 months resulted in higher peak antibody responses. These observations can broadly inform strategic approaches for pandemic preparedness. Clinical Trials Registration. NCT03589807.


Asunto(s)
Anticuerpos Antivirales , Inmunización Secundaria , Subtipo H7N9 del Virus de la Influenza A , Vacunas contra la Influenza , Gripe Humana , Vacunas de Productos Inactivados , Humanos , Vacunas contra la Influenza/inmunología , Vacunas contra la Influenza/administración & dosificación , Vacunas contra la Influenza/efectos adversos , Adulto , Masculino , Femenino , Persona de Mediana Edad , Subtipo H7N9 del Virus de la Influenza A/inmunología , Vacunas de Productos Inactivados/inmunología , Vacunas de Productos Inactivados/administración & dosificación , Vacunas de Productos Inactivados/efectos adversos , Anticuerpos Antivirales/sangre , Gripe Humana/prevención & control , Gripe Humana/inmunología , Adulto Joven , Esquemas de Inmunización , Pruebas de Inhibición de Hemaglutinación , Estados Unidos , Inmunogenicidad Vacunal , Anticuerpos Neutralizantes/sangre , Polisorbatos/administración & dosificación , Polisorbatos/efectos adversos , alfa-Tocoferol/administración & dosificación , alfa-Tocoferol/efectos adversos , Escualeno/administración & dosificación , Escualeno/efectos adversos , Escualeno/inmunología , Voluntarios Sanos , Combinación de Medicamentos , Adyuvantes de Vacunas/administración & dosificación , Vacunación/métodos , Adyuvantes Inmunológicos/administración & dosificación , Adyuvantes Inmunológicos/efectos adversos
6.
J Cardiovasc Electrophysiol ; 35(6): 1061-1068, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38501564

RESUMEN

INTRODUCTION: The relationships between baseline tissue local impedance (LI), contact force (CF), atrial fibrosis, and atrial rhythm are uninvestigated in a clinical setting. We compared the relationship of LI and CF between atrial fibrillation (AF) and sinus rhythm (SR) accounting for the effects of atrial fibrosis as assessed by bipolar voltage and LI. METHODS: Patients undergoing persistent AF ablation were recruited. LI was recorded referenced to patient blood pool (LIr) and concurrent to changes in CF, with data collected at the same locations in AF and SR. RESULTS: Twenty patients were recruited. 109 locations were sampled obtaining 1903 data points (SR: 966, AF: 937). CF correlated strongly with LI (repeated measures correlation = 0.64). The relationship between CF and LIr was logarithmic. Rhythm and CF had a significant main (both p < .0005) and interaction effect (p = .022) on tissue LI: AF demonstrated higher LIr values than SR for similar CF. Bipolar voltage had no effect on the relationship of CF to LIr in either rhythm. Assessing fibrosis using LIr showed an interaction effect with CF for LIr in SR and AF, (SR: p < .0005, AF: p = .01), with increased fibrosis showing lesser change in LIr per gram of CF. CONCLUSIONS: CF and rhythm significantly affect the measured LIr of LA myocardium. Optimal catheter-tissue coupling may be better achieved with higher levels of CF and in AF rather than SR. Atrial fibrosis, as assessed by LIr but not bipolar voltage, affected the CF-LI relationship.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Función del Atrio Izquierdo , Ablación por Catéter , Fibrosis , Atrios Cardíacos , Frecuencia Cardíaca , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Persona de Mediana Edad , Atrios Cardíacos/fisiopatología , Anciano , Factores de Tiempo , Técnicas Electrofisiológicas Cardíacas , Impedancia Eléctrica , Valor Predictivo de las Pruebas , Resultado del Tratamiento , Remodelación Atrial
7.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38861398

RESUMEN

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) offer potentially distinct advantages over transvenous defibrillator systems. Recent randomized trials showed significantly lower lead failure rates than transvenous ICD. Still, S-ICDs remain associated with the risk of inappropriate shocks (IAS). While previous studies have reported varying causes of IAS, this study explores a rare cause of IAS, referred to as 'sense-B-noise.' It was recently described in case series, but its incidence has not been studied in a large cohort of S-ICD patients. METHODS AND RESULTS: We retrospectively reviewed data from patients implanted with S-ICD models 1010, A209, and A219 between October 2009 and July 2023 across nine centres in Europe and the USA. The analysis concentrated on determining the incidence and understanding the implications of sense-B-noise events. Sense-B-noise represents a rare manifestation of distinct electrogram abnormalities within the primary and alternate sensing vectors. Data were collected from medical records, device telemetry, and manufacturer reports for investigation. This registry is registered on clinicaltrials.gov (NCT05713708). Subcutaneous implantable cardioverter-defibrillator devices of the 1158 patients were analysed. The median follow-up time for all patients was 46 (IQR 23-64) months. In 107 patients (9.2%) ≥1 IAS was observed during follow-up. Sense-B-noise failure was diagnosed in six (0.5 and 5.6% of all IAS) patients, in all patients, the diagnosis was made after an IAS episode. Median lead dwell time in the affected patients was 23 (2-70) months. To resolve the sense-B-noise defect, in three patients reprogramming to the secondary vector was undertaken, and two patients underwent system removal with subsequent S-ICD reimplantation due to low amplitude in the secondary vector. In one patient, the secondary vector was initially programmed, and subsequently, an S-ICD system exchange was performed due to T-wave-oversensing IAS episodes. CONCLUSION: This multicentre analysis' findings shed light on a rare but clinically highly significant adverse event in S-ICD therapy. To our knowledge, we provide the first systematic multicentre analysis investigating the incidence of sense-B-noise. Due to being difficult to diagnose and limited options for resolution, management of sense-B-noise is challenging. Complete system exchange may be the only option for some patients. Educating healthcare providers involved in S-ICD patient care is crucial for ensuring accurate diagnosis and effective management of sense-B-noise issues.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica , Sistema de Registros , Humanos , Masculino , Estudios Retrospectivos , Femenino , Persona de Mediana Edad , Incidencia , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Anciano , Europa (Continente)/epidemiología , Falla de Equipo/estadística & datos numéricos , Estados Unidos/epidemiología , Factores de Riesgo
8.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38885309

RESUMEN

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have become established in preventing sudden cardiac death, with some advantages over transvenous defibrillator systems, including a lower incidence of lead failures. Despite technological advancements, S-ICD carriers may suffer from significant complications, such as premature battery depletion (PBD), that led to an advisory for nearly 40 000 patients. This multicentre study evaluated the incidence of PBD in a large set of S-ICD patients. METHODS AND RESULTS: Data from patients implanted with S-ICD models A209 and A219 between October 2012 and July 2023 across nine centres in Europe and the USA were reviewed. Incidence and implications of PBD, defined as clinically observed sudden drop in battery longevity, were analysed and compared to PBD with the definition of battery depletion within 60 months. Prospectively collected clinical data were obtained retrospectively from medical records, device telemetry, and manufacturer reports. This registry is listed on ClinicalTrials.gov (NCT05713708). Of the 1112 S-ICD devices analysed, 547 (49.2%) were equipped with a potentially affected capacitor linked to PBD occurrence, currently under Food and Drug Administration advisory. The median follow-up time for all patients was 46 [inter-quartile range (IQR) 24-63] months. Clinically suspected PBD was observed in 159 (29.1%) of cases, with a median time to generator removal or replacement of 65 (IQR 55-72) months, indicative of significant deviations from expected battery lifespan. Manufacturer confirmation of PBD was made in 91.7% of devices returned for analysis. No cases of PBD were observed in devices that were not under advisory. CONCLUSION: This manufacturer-independent analysis highlights a notable incidence of PBD in patients equipped with S-ICD models under advisory, and the rate of PBD in this study corresponds to the rate currently estimated by the manufacturer. To the best of our knowledge, this provides the largest contemporary peer-reviewed study cohort investigating the actual incidence of PBD in S-ICD patients. These findings emphasize the importance of post-market registries in collaboration between clinicians and the manufacturer to optimize safety and efficacy in S-ICD treatment.


Asunto(s)
Desfibriladores Implantables , Suministros de Energía Eléctrica , Sistema de Registros , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Anciano , Estados Unidos/epidemiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/epidemiología , Europa (Continente)/epidemiología , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Falla de Equipo/estadística & datos numéricos , Factores de Tiempo , Análisis de Falla de Equipo/estadística & datos numéricos , Adulto
9.
Pacing Clin Electrophysiol ; 47(2): 195-202, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38214035

RESUMEN

BACKGROUND: Peri-procedural complications associated with cardiac implantable electronic devices are not uncommon. European Society of Cardiology guidelines recommend device checks of all devices within 72 h of implant. European Heart Rhythm Association expert practical guide on Cardiac implantable electronic devices (CIEDs) recommend that a chest x-ray (CXR) should be performed within 24 h to rule out pneumothorax and document lead positions. First, the rate of peri-procedural complications associated with CIED implants at our center, as well as patient and/or procedural-related factors that are associated with higher rates of complications, is analyzed. Second, the yield of the guideline-recommended measures in the early detection of peri-procedural complications is examined. MATERIALS AND METHODS: Consecutive de novo transvenous device implants at our center in 2019 were retrospectively analyzed. Patients' demographics, types and indications for device therapy, procedural reports, device checks, and CXRs were obtained from the hospital electronic records. RESULTS: A total of 578 patients (Age 74 ± 16 years, 68% male) were included. All patients had routine post-procedure CXRs and device checks. There were 16 (2.8%) complications; 7 (1.2%) pneumothoraxes, 6 (1%) pericardial effusions, and 3 (0.5%) lead displacements. Procedure time correlated significantly with complications; in uncomplicated cases it was 99 ± 43 min versus 127 ± 50 min in procedures associated with complications (p = .02). CONCLUSIONS: Routine post CIED implantation CXRs can detect early peri-procedural complications, while repeat post mobilization device checks has low yield of detection of complications. The only statistically significant predictor of peri-procedural complications is the duration of the procedure; longer procedures were associated with higher rates of complications.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Desfibriladores Implantables/efectos adversos , Estudios Retrospectivos , Corazón , Reino Unido , Marcapaso Artificial/efectos adversos
10.
Bull Math Biol ; 86(5): 52, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38592370

RESUMEN

This paper offers advice to early-mid career researchers in Mathematical Biology from ten past and current Presidents of the Society for Mathematical Biology. The topics covered include deciding if a career in academia is right for you; finding and working with a mentor; building collaborations and working with those from other disciplines; formulating a research question; writing a paper; reviewing papers; networking; writing fellowship or grant proposals; applying for faculty positions; and preparing and giving lectures. While written with mathematical biologists in mind, it is hoped that this paper will be of use to early and mid career researchers across the mathematical, physical and life sciences, as they embark on careers in these disciplines.


Asunto(s)
Disciplinas de las Ciencias Biológicas , Conceptos Matemáticos , Modelos Biológicos
11.
Indian Pacing Electrophysiol J ; 24(4): 192-199, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38871179

RESUMEN

INTRODUCTION: The risk of complications associated with transvenous ICDs make the subcutaneous implantable cardiac defibrillator (S-ICD) a valuable alternative in patients with adult congenital heart disease (ACHD). However, higher S-ICD ineligibility and higher inappropriate shock rates-mostly caused by T wave oversensing (TWO)- are observed in this population. We report a novel application of deep learning methods to screen patients for S-ICD eligibility over a longer period than conventional screening. METHODS: Adult patients with ACHD and a control group of normal subjects were fitted with a 24-h Holters to record their S-ICD vectors. Their T:R ratio was analysed utilising phase space reconstruction matrices and a deep learning-based model to provide an in-depth description of the T: R variation plot for each vector. T: R variation was compared statistically using t-test. RESULTS: 13 patients (age 37.4 ± 7.89 years, 61.5 % male, 6 ACHD and 7 control subjects) were enrolled. A significant difference was observed in the mean and median T: R values between the two groups (p < 0.001). There was also a significant difference in the standard deviation of T: R between both groups (p = 0.04). CONCLUSIONS: T:R ratio, a main determinant for S-ICD eligibility, is significantly higher with more tendency to fluctuate in ACHD patients when compared to a population with normal hearts. We hypothesise that our novel model could be used to select S-ICD eligible patients by better characterisation of T:R ratio, reducing the risk of TWO and inappropriate shocks in the ACHD patient cohort.

12.
J Infect Dis ; 228(3): 287-298, 2023 08 11.
Artículo en Inglés | MEDLINE | ID: mdl-36702771

RESUMEN

BACKGROUND: We evaluated the associations between baseline influenza virus-specific hemagglutination inhibition (HAI) and microneutralization (MN) titers and subsequent symptomatic influenza virus infection in a controlled human infection study. METHODS: We inoculated unvaccinated healthy adults aged 18-49 years with an influenza A/California/04/2009/H1N1pdm-like virus (NCT04044352). We collected serial safety labs, serum for HAI and MN, and nasopharyngeal swabs for reverse-transcription polymerase chain reaction (RT-PCR) testing. Analyses used the putative seroprotective titer of ≥40 for HAI and MN. The primary clinical outcome was mild-to-moderate influenza disease (MMID), defined as ≥1 postchallenge positive qualitative RT-PCR test with a qualifying symptom/clinical finding. RESULTS: Of 76 participants given influenza virus challenge, 54 (71.1%) experienced MMID. Clinical illness was generally very mild. MMID attack rates among participants with baseline titers ≥40 by HAI and MN were 64.9% and 67.9%, respectively, while MMID attack rates among participants with baseline titers <40 by HAI and MN were 76.9% and 78.3%, respectively. The estimated odds of developing MMID decreased by 19% (odds ratio, 0.81 [95% confidence interval, .62-1.06]; P = .126) for every 2-fold increase in baseline HAI. There were no significant adverse events. CONCLUSIONS: We achieved a 71.1% attack rate of MMID. High baseline HAI and MN were associated with protection from illness. Clinical Trials Registration. NCT04044352.


Asunto(s)
Subtipo H1N1 del Virus de la Influenza A , Vacunas contra la Influenza , Gripe Humana , Humanos , Adulto , Gripe Humana/prevención & control , Anticuerpos Antivirales , Proyectos de Investigación , Pruebas de Inhibición de Hemaglutinación
14.
Clin Infect Dis ; 77(4): 560-564, 2023 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-37036397

RESUMEN

In a randomized clinical trial, we compare early neutralizing antibody responses after boosting with bivalent severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) messenger RNA (mRNA) vaccines based on either BA.1 or BA.4/BA.5 Omicron spike protein combined with wild-type spike. Responses against SARS-CoV-2 variants exhibited the greatest reduction in titers against currently circulating Omicron subvariants for both bivalent vaccines.


Asunto(s)
COVID-19 , Humanos , COVID-19/prevención & control , SARS-CoV-2/genética , Anticuerpos Neutralizantes , Vacunas Combinadas , Anticuerpos Antivirales
15.
N Engl J Med ; 383(20): 1920-1931, 2020 11 12.
Artículo en Inglés | MEDLINE | ID: mdl-32663912

RESUMEN

BACKGROUND: The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) emerged in late 2019 and spread globally, prompting an international effort to accelerate development of a vaccine. The candidate vaccine mRNA-1273 encodes the stabilized prefusion SARS-CoV-2 spike protein. METHODS: We conducted a phase 1, dose-escalation, open-label trial including 45 healthy adults, 18 to 55 years of age, who received two vaccinations, 28 days apart, with mRNA-1273 in a dose of 25 µg, 100 µg, or 250 µg. There were 15 participants in each dose group. RESULTS: After the first vaccination, antibody responses were higher with higher dose (day 29 enzyme-linked immunosorbent assay anti-S-2P antibody geometric mean titer [GMT], 40,227 in the 25-µg group, 109,209 in the 100-µg group, and 213,526 in the 250-µg group). After the second vaccination, the titers increased (day 57 GMT, 299,751, 782,719, and 1,192,154, respectively). After the second vaccination, serum-neutralizing activity was detected by two methods in all participants evaluated, with values generally similar to those in the upper half of the distribution of a panel of control convalescent serum specimens. Solicited adverse events that occurred in more than half the participants included fatigue, chills, headache, myalgia, and pain at the injection site. Systemic adverse events were more common after the second vaccination, particularly with the highest dose, and three participants (21%) in the 250-µg dose group reported one or more severe adverse events. CONCLUSIONS: The mRNA-1273 vaccine induced anti-SARS-CoV-2 immune responses in all participants, and no trial-limiting safety concerns were identified. These findings support further development of this vaccine. (Funded by the National Institute of Allergy and Infectious Diseases and others; mRNA-1273 ClinicalTrials.gov number, NCT04283461).


Asunto(s)
Infecciones por Coronavirus/prevención & control , Pandemias/prevención & control , Neumonía Viral/prevención & control , ARN Mensajero/inmunología , Glicoproteína de la Espiga del Coronavirus/inmunología , Vacunas Virales/uso terapéutico , Vacuna nCoV-2019 mRNA-1273 , Adulto , Anticuerpos Neutralizantes/sangre , Anticuerpos Antivirales/sangre , Formación de Anticuerpos , Betacoronavirus , COVID-19 , Vacunas contra la COVID-19 , Femenino , Humanos , Inmunización Secundaria , Masculino , SARS-CoV-2 , Linfocitos T/inmunología , Vacunas Virales/efectos adversos , Adulto Joven
16.
N Engl J Med ; 383(25): 2427-2438, 2020 12 17.
Artículo en Inglés | MEDLINE | ID: mdl-32991794

RESUMEN

BACKGROUND: Testing of vaccine candidates to prevent infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in an older population is important, since increased incidences of illness and death from coronavirus disease 2019 (Covid-19) have been associated with an older age. METHODS: We conducted a phase 1, dose-escalation, open-label trial of a messenger RNA vaccine, mRNA-1273, which encodes the stabilized prefusion SARS-CoV-2 spike protein (S-2P) in healthy adults. The trial was expanded to include 40 older adults, who were stratified according to age (56 to 70 years or ≥71 years). All the participants were assigned sequentially to receive two doses of either 25 µg or 100 µg of vaccine administered 28 days apart. RESULTS: Solicited adverse events were predominantly mild or moderate in severity and most frequently included fatigue, chills, headache, myalgia, and pain at the injection site. Such adverse events were dose-dependent and were more common after the second immunization. Binding-antibody responses increased rapidly after the first immunization. By day 57, among the participants who received the 25-µg dose, the anti-S-2P geometric mean titer (GMT) was 323,945 among those between the ages of 56 and 70 years and 1,128,391 among those who were 71 years of age or older; among the participants who received the 100-µg dose, the GMT in the two age subgroups was 1,183,066 and 3,638,522, respectively. After the second immunization, serum neutralizing activity was detected in all the participants by multiple methods. Binding- and neutralizing-antibody responses appeared to be similar to those previously reported among vaccine recipients between the ages of 18 and 55 years and were above the median of a panel of controls who had donated convalescent serum. The vaccine elicited a strong CD4 cytokine response involving type 1 helper T cells. CONCLUSIONS: In this small study involving older adults, adverse events associated with the mRNA-1273 vaccine were mainly mild or moderate. The 100-µg dose induced higher binding- and neutralizing-antibody titers than the 25-µg dose, which supports the use of the 100-µg dose in a phase 3 vaccine trial. (Funded by the National Institute of Allergy and Infectious Diseases and others; mRNA-1273 Study ClinicalTrials.gov number, NCT04283461.).


Asunto(s)
Vacunas contra la COVID-19/efectos adversos , Vacunas contra la COVID-19/inmunología , COVID-19/prevención & control , SARS-CoV-2/inmunología , Vacuna nCoV-2019 mRNA-1273 , Anciano , Anticuerpos Neutralizantes/sangre , Anticuerpos Antivirales/sangre , COVID-19/inmunología , Vacunas contra la COVID-19/administración & dosificación , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pruebas de Neutralización , Glicoproteína de la Espiga del Coronavirus , Linfocitos T/fisiología
17.
PLoS Pathog ; 17(10): e1010015, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34665847

RESUMEN

Clostridioides difficile infections occur upon ecological / metabolic disruptions to the normal colonic microbiota, commonly due to broad-spectrum antibiotic use. Metabolism of bile acids through a 7α-dehydroxylation pathway found in select members of the healthy microbiota is regarded to be the protective mechanism by which C. difficile is excluded. These 7α-dehydroxylated secondary bile acids are highly toxic to C. difficile vegetative growth, and antibiotic treatment abolishes the bacteria that perform this metabolism. However, the data that supports the hypothesis that secondary bile acids protect against C. difficile infection is supported only by in vitro data and correlative studies. Here we show that bacteria that 7α-dehydroxylate primary bile acids protect against C. difficile infection in a bile acid-independent manner. We monoassociated germ-free, wildtype or Cyp8b1-/- (cholic acid-deficient) mutant mice and infected them with C. difficile spores. We show that 7α-dehydroxylation (i.e., secondary bile acid generation) is dispensable for protection against C. difficile infection and provide evidence that Stickland metabolism by these organisms consumes nutrients essential for C. difficile growth. Our findings indicate secondary bile acid production by the microbiome is a useful biomarker for a C. difficile-resistant environment but the microbiome protects against C. difficile infection in bile acid-independent mechanisms.


Asunto(s)
Ácidos y Sales Biliares/metabolismo , Infecciones por Clostridium/metabolismo , Resistencia a la Enfermedad/fisiología , Microbioma Gastrointestinal/fisiología , Animales , Ratones , Ratones Noqueados
18.
J Org Chem ; 88(13): 8093-8098, 2023 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-37311064

RESUMEN

The synthesis of a range of loline alkaloids is reported. The C(7) and C(7a) stereogenic centers for the targets were formed by the established conjugate addition of lithium (S)-N-benzyl-N-(α-methylbenzyl)amide to tert-butyl 5-benzyloxypent-2-enoate, ensuing enolate oxidation to give an α-hydroxy-ß-amino ester, and then formal exchange of the resultant amino and hydroxyl functionalities (via the intermediacy of the corresponding aziridinium ion) to give an α-amino-ß-hydroxy ester. Subsequent transformation gave a 3-hydroxyprolinal derivative which was converted to the corresponding N-tert-butylsulfinylimine. Mannich-type reaction with the enolate derived from O-Boc protected methyl glycolate then formed the remaining C(1) and C(2) stereogenic centers for the targets. The 2,7-ether bridge was formed by a displacement reaction, completing construction of the loline alkaloid core. Facile manipulations then gave a range of loline alkaloids, including loline itself.


Asunto(s)
Alcaloides , Alcaloides de Pirrolicidina , Oxidación-Reducción , Estereoisomerismo
19.
Pacing Clin Electrophysiol ; 46(9): 1085-1091, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37428941

RESUMEN

BACKGROUND: Leadless pacemakers have been developed to avoid some of the complications that are associated transvenous pacemakers. Pericardial effusion is a rare complication of leadless pacemaker implantation, which may result from perforation of the delivery catheter. In this study, we describe preclinical perforation performance of an updated Micra delivery catheter. METHODS: To assess preclinical perforation performance of the updated delivery catheter, three analyses were performed. First, Finite Element Analysis (FEA) computational modeling was performed to estimate the target tissue stress during Micra delivery catheter tenting. Second, benchtop perforation forces of ovine tissue were recorded for the original and updated delivery catheters. Finally, a Monte-Carlo simulation combining human cadaveric Micra implant forces and human ventricular tissue perforation properties was performed to estimate clinical perforation performance. RESULTS: FEA modeling demonstrated a 66% reduction in target tissue stress when using the updated Micra delivery catheter (6.2 vs. 2.2 psi, Original vs. Updated Micra delivery catheter). Updated Micra delivery catheters required 20% more force to perforate porcine ventricular tissues in benchtop testing (µupd  = 26.9N vs. µorg  = 22.4N, p = .01). Monte-Carlo Simulation of catheter performance in human cadaveric tissues predicts 28.5% reduction of catheter-perforated cases with the updated delivery catheter. CONCLUSIONS: This study, using computer modelling and benchtop experimentation, has indicated that increased surface area and rounding of the updated Micra catheter tip significantly improves preclinical perforation performance. It will be important to evaluate the impact of these catheter design changes with robust registry data.


Asunto(s)
Marcapaso Artificial , Humanos , Animales , Ovinos , Porcinos , Resultado del Tratamiento , Diseño de Equipo , Ventrículos Cardíacos , Cadáver
20.
Ann Noninvasive Electrocardiol ; 28(1): e13028, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36524869

RESUMEN

INTRODUCTION: S-ICD eligibility is assessed at pre-implant screening where surface ECG traces are used as surrogates for S-ICD vectors. In heart failure (HF) patients undergoing diuresis, electrolytes and fluid shifts can cause changes in R and T waves. Subsequently, T:R ratio, a major predictor of S-ICD eligibility, can be dynamic. METHODS: This is a prospective study of patients with structurally normal hearts and HF patients undergoing diuresis. All patients were fitted with Holters® to record their S-ICD vectors. Our deep learning model was used to analyze the T:R ratios across the recordings. Welch two sample t-test and Mann-Whitney U were used to compare the data between the two groups. RESULTS: Twenty-one patients (age 58.43 ± 18.92, 62% male, 14 HF, 7 normal hearts) were enrolled. There was a significant difference in the T:R ratios between both groups. Mean T: R was higher in the HF group (0.18 ± 0.08 vs 0.10 ± 0.05, p < .001). Standard deviation of T: R was also higher in the HF group (0.09 ± 0.05 vs 0.07 ± 0.04, p = .024). There was no difference between leads within the same group. CONCLUSIONS: T:R ratio, a main determinant for S-ICD eligibility, is higher and has more tendency to fluctuate in HF patients undergoing diuresis. We hypothesize that our novel neural network model could be used to select HF patients eligible for S-ICD by better characterization of T:R ratio reducing the risk of T-wave over-sensing (TWO) and inappropriate shocks. Further work is required to consolidate our findings before applying to clinical practice.


Asunto(s)
Aprendizaje Profundo , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Masculino , Adulto , Persona de Mediana Edad , Anciano , Femenino , Desfibriladores Implantables/efectos adversos , Muerte Súbita Cardíaca/etiología , Electrocardiografía/métodos , Estudios Prospectivos , Arritmias Cardíacas/complicaciones , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA