Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Microsc ; 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38711338

RESUMEN

Here we show that compressive sensing allows 4-dimensional (4-D) STEM data to be obtained and accurately reconstructed with both high-speed and reduced electron fluence. The methodology needed to achieve these results compared to conventional 4-D approaches requires only that a random subset of probe locations is acquired from the typical regular scanning grid, which immediately generates both higher speed and the lower fluence experimentally. We also consider downsampling of the detector, showing that oversampling is inherent within convergent beam electron diffraction (CBED) patterns and that detector downsampling does not reduce precision but allows faster experimental data acquisition. Analysis of an experimental atomic resolution yttrium silicide dataset shows that it is possible to recover over 25 dB peak signal-to-noise ratio in the recovered phase using 0.3% of the total data. Lay abstract: Four-dimensional scanning transmission electron microscopy (4-D STEM) is a powerful technique for characterizing complex nanoscale structures. In this method, a convergent beam electron diffraction pattern (CBED) is acquired at each probe location during the scan of the sample. This means that a 2-dimensional signal is acquired at each 2-D probe location, equating to a 4-D dataset. Despite the recent development of fast direct electron detectors, some capable of 100kHz frame rates, the limiting factor for 4-D STEM is acquisition times in the majority of cases, where cameras will typically operate on the order of 2kHz. This means that a raster scan containing 256^2 probe locations can take on the order of 30s, approximately 100-1000 times longer than a conventional STEM imaging technique using monolithic radial detectors. As a result, 4-D STEM acquisitions can be subject to adverse effects such as drift, beam damage, and sample contamination. Recent advances in computational imaging techniques for STEM have allowed for faster acquisition speeds by way of acquiring only a random subset of probe locations from the field of view. By doing this, the acquisition time is significantly reduced, in some cases by a factor of 10-100 times. The acquired data is then processed to fill-in or inpaint the missing data, taking advantage of the inherently low-complex signals which can be linearly combined to recover the information. In this work, similar methods are demonstrated for the acquisition of 4-D STEM data, where only a random subset of CBED patterns are acquired over the raster scan. We simulate the compressive sensing acquisition method for 4-D STEM and present our findings for a variety of analysis techniques such as ptychography and differential phase contrast. Our results show that acquisition times can be significantly reduced on the order of 100-300 times, therefore improving existing frame rates, as well as further reducing the electron fluence beyond just using a faster camera.

2.
J Microsc ; 290(1): 53-66, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36800515

RESUMEN

Scanning transmission electron microscopy images can be complex to interpret on the atomic scale as the contrast is sensitive to multiple factors such as sample thickness, composition, defects and aberrations. Simulations are commonly used to validate or interpret real experimental images, but they come at a cost of either long computation times or specialist hardware such as graphics processing units. Recent works in compressive sensing for experimental STEM images have shown that it is possible to significantly reduce the amount of acquired signal and still recover the full image without significant loss of image quality, and therefore it is proposed here that similar methods can be applied to STEM simulations. In this paper, we demonstrate a method that can significantly increase the efficiency of STEM simulations through a targeted sampling strategy, along with a new approach to independently subsample each frozen phonon layer. We show the effectiveness of this method by simulating a SrTiO3 grain boundary and monolayer 2H-MoS2 containing a sulphur vacancy using the abTEM software. We also show how this method is not limited to only traditional multislice methods, but also increases the speed of the PRISM simulation method. Furthermore, we discuss the possibility for STEM simulations to seed the acquisition of real data, to potentially lead the way to self-driving (correcting) STEM.

6.
Ultramicroscopy ; 242: 113625, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36183423

RESUMEN

Recently it has been shown that precise dose control and an increase in the overall acquisition speed of atomic resolution scanning transmission electron microscope (STEM) images can be achieved by acquiring only a small fraction of the pixels in the image experimentally and then reconstructing the full image using an inpainting algorithm. In this paper, we apply the same inpainting approach (a form of compressed sensing) to simulated, sub-sampled atomic resolution STEM images. We find that it is possible to significantly sub-sample the area that is simulated, the number of g-vectors contributing the image, and the number of frozen phonon configurations contributing to the final image while still producing an acceptable fit to a fully sampled simulation. Here we discuss the parameters that we use and how the resulting simulations can be quantifiably compared to the full simulations. As with any Compressed Sensing methodology, care must be taken to ensure that isolated events are not excluded from the process, but the observed increase in simulation speed provides significant opportunities for real time simulations, image classification and analytics to be performed as a supplement to experiments on a microscope to be developed in the future.