Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Rev Invest Clin ; 66 Suppl 1: S85-93, 2014 Jul.
Artículo en Español | MEDLINE | ID: mdl-25264803

RESUMEN

Knowledge of the general characteristics and physical condition that keeps the transfemoral amputation stump to select and adapt appropriate type of prosthesis to restore a walking pattern amputee patient acceptable and useful design parameters set to propose new prosthetic systems. In this paper, the degree of difference between the volumes of the limb stump and healthy as well as morphological features occurred more frequently in the stumps of transfemoral amputees who were treated at the Laboratory of Orthotics and Prosthetics (LOP), Instituto Nacional de Rehabilitación (INR) in 2008. It captured all patients with unilateral transfemoral amputation left and right, over 18 years old, both sexes, use of hearing candidates were evaluated clinically and took three measurements of the circumferences at different wavelengths and the limb stump healthy, were calculated volumes of both sides using the mathematical model of the truncated cone and analyzed in three groups according to the level of amputation (proximal, middle and distal third). We obtained 49 patients, 39 men and 10 women, the difference stump volume compared to healthy limb volume per group were: 44.9% proximal third, middle third and distal 26.5%, 21.1%, the frequency of diagnostic data showed a stump right transfemoral amputees, due to metabolic, without use of prostheses, the most common morphological features indicate that the stump has a conical shape and size distal third, whose tissue is semi-flaccid consistency, the scar is not adhered to deep planes and shows a negative tinel, the mattress soft tissue is 2.15 ± 1.3 cm and physically presents a force level 4 in the clinical rating scale Daniels. The data are consistent with other studies comparing the percentage of the volume change with the percentages of reduced diameters transfemoral stump muscle, likewise agrees most amputees incidence of diabetes mellitus with other studies, cataloging it eat first cause amputation. The general description developed transfemoral stump-served in the INR will help in the process of manufacture of prostheses and prosthetic design new systems that you attend these needs.


Asunto(s)
Muñones de Amputación , Amputados , Miembros Artificiales , Cicatriz/patología , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Teóricos , Diseño de Prótesis
2.
Rev Invest Clin ; 66 Suppl 1: S131-41, 2014 Jul.
Artículo en Español | MEDLINE | ID: mdl-25264793

RESUMEN

A device for dynamic acquisition and distribution analysis of in-socket pressure for patients with partial foot amputation is presented in this work. By using the developed system, we measured and generated pressure distribution graphs, obtained maximal pressure, and calculated pressure-time integral (PTI) of three subjects with partial foot amputation and of a group of Healthy subjects (Hs) (n = 10). Average maximal pressure in the healthy group was 19.4 ± 4.11 PSI, while for the three amputated patients, this was 27.8 ± 1.38, 17.6 ± 1.15, 29.10 ± 3.9 PSI, respectively. Maximal pressure-time integral for healthy subjects was 11.56 ± 2.83 PSI*s, and for study subjects was 19.54 ± 1.9, 12.35 ± 1.48, and 13.17 ± 1.31 PSI*s, respectively. The results of the control group agree with those previously reported in the literature. The pressure distribution pattern showed clear differences between study subjects and those of the control group; these graphs allowed us to identify the pressure in regions-of-interest that could be critical, such as surgical scars. The system presented in this work will aid to assess the effectiveness with which prosthetic systems distribute load, given that the formation of ulcers is highly linked to the pressure exercised at the point of contact; in addition, these results will help to investigate the comfort perception of the prosthesis, a factor directly influenced by the stump's pressure distribution.


Asunto(s)
Amputación Quirúrgica , Úlcera del Pie/etiología , Pie , Presión , Adulto , Estudios de Casos y Controles , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Úlcera por Presión/etiología , Diseño de Prótesis , Adulto Joven
3.
Rev Invest Clin ; 66 Suppl 1: S24-31, 2014 Jul.
Artículo en Español | MEDLINE | ID: mdl-25264794

RESUMEN

Familiarization to treadmill walking in unimpaired Parkinson's disease (PD) patients is assessed, across multiple treadmill walking sessions. Thirteen PD subjects were enrolled into the study (Eight were in a moderate stage of the disease, and 5 in an advanced stage). PD subjects attended a progressive program consisting of 12 sessions of 20 min. Walking speed, cadence, step length and coefficient of variation were assessed. ANOVA test were used to evaluate progression of disease and time influence over familiarization. PD Subjects baseline characteristics did not differ significantly between both groups and typical dependencies over progression of disease and velocity were found for cadence, step length and coefficient of variation. However, we showed that some PD subjects may require longer familiarization times and that familiarization is an adaptation process which involves parameters as velocity, cadence and gait stability. A better definition of familiarization to treadmill is needed since some parameters such as step length does not change significantly while others such as cadence, coefficient of variation and intraclass correlation coefficient does. Therefore familiarization to treadmill walking should remain on measures of velocity, cadence, reliability and variability. However, a bigger sample size is needed in order to improve the results of the present study.


Asunto(s)
Adaptación Fisiológica/fisiología , Enfermedad de Parkinson/fisiopatología , Caminata/fisiología , Anciano , Prueba de Esfuerzo , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Factores de Tiempo
4.
Rev Invest Clin ; 66 Suppl 1: S39-47, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25264796

RESUMEN

Virtual reality (VR) in neurorehabilitation allows to reduce patient's risk and allows him to learn on a faster way. Up to now VR has been used in patients with Parkinson disease (PD) as a research tool and none of the developed systems are used in clinical practice. The goal of this project is to develop a VR-based system for gait therapy, and gait research of patients with PD designed based on published evidence. The developed system uses a digital camera to measure spatiotemporal gait parameters. The software was developed in C#, using Open-Source libraries that facilitates VR programming. The system has potential uses in clinical and research settings.


Asunto(s)
Prueba de Esfuerzo/métodos , Marcha/fisiología , Enfermedad de Parkinson/rehabilitación , Interfaz Usuario-Computador , Adulto , Anciano , Anciano de 80 o más Años , Medicina Basada en la Evidencia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad de Parkinson/fisiopatología , Adulto Joven
5.
Rev Invest Clin ; 66 Suppl 1: S79-84, 2014 Jul.
Artículo en Español | MEDLINE | ID: mdl-25264801

RESUMEN

Percutaneous surgical techniques are suitable for the correction of the hallux valgus deformity. Satisfactory aesthetic and functional results obtained with the Reverdin- Isham osteotomy have been reported. The aim of this study was to describe dynamic plantar pressure redistribution after the correction of the deformity using this technique. A sample of 20 feet with mild or moderate hallux valgus was conformed and surgically treated using the Reverdin-Isham osteotomy. Clinical, radiological, surface and pressure assessments were performed pre and postoperatively. Postoperative mean (± SD) values of the American Orthopaedic Foot and Ankle Society (AOFAS) score, metatarsophalangeal, first intermetatarsal and proximal articular sect angles were 95.7 (3.3), 15.5° (5.4), 9.5° (1.5) y 5.3° (3.0), respectively. A significant decrease was observed in surface values of both lateral (P = 0.003) and medial (P = 0.001) masks of the forefoot. Mean pressure values of the lateral forefoot region denoted a significant increase (P < 0.001) while the medial forefoot region showed no change (P = 0.137). There is evidence that this particular surgical technique promotes a new plantar pressure pattern in the foot that might significantly favour the increase of the pressure observed under the lesser metatarsal heads and might not induce meaningful changes in the mean pressure registered under the first metatarsal head and hallux.


Asunto(s)
Hallux Valgus/cirugía , Osteotomía/métodos , Adulto , Femenino , Hallux Valgus/diagnóstico por imagen , Humanos , Masculino , Huesos Metatarsianos , Persona de Mediana Edad , Presión , Radiografía , Resultado del Tratamiento
6.
J Pers Med ; 14(8)2024 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-39202064

RESUMEN

Functional electrical stimulation (FES) is a rehabilitation and assistive technique used for stroke survivors. FES systems mainly consist of sensors, a control algorithm, and a stimulation unit. However, there is a critical need to reassess sensing and control techniques in FES systems to enhance their efficiency. This SLR was carried out following the PRISMA 2020 statement. Four databases (PubMed, Scopus, Web of Science, Wiley Online Library) from 2010 to 2024 were searched using terms related to sensing and control strategies in FES systems. A total of 322 articles were chosen in the first stage, while only 60 of them remained after the final filtering stage. This systematic review mainly focused on sensor techniques and control strategies to deliver FES. The most commonly used sensors reported were inertial measurement units (IMUs), 45% (27); biopotential electrodes, 36.7% (22); vision-based systems, 18.3% (11); and switches, 18.3% (11). The control strategy most reported is closed-loop; however, most of the current commercial FES systems employ open-loop strategies due to their simplicity. Three main factors were identified that should be considered when choosing a sensor for gait-oriented FES systems: wearability, accuracy, and affordability. We believe that the combination of computer vision systems with artificial intelligence-based control algorithms can contribute to the development of minimally invasive and personalized FES systems for the gait rehabilitation of patients with FDS.

7.
J Spinal Cord Med ; : 1-9, 2023 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-37036293

RESUMEN

BACKGROUND: Wheelchairs are vital for the successful rehabilitation and inclusion of people with mobility disabilities; 10% of the population with disabilities needs a wheelchair, but only 15% have access to an adequate one. Not user-configured wheelchairs may lead to postural deformities and pressure ulcers, thus negatively impact user satisfaction, wheelchair skills, and quality of life. OBJECTIVE: To assess the impact of the 8-step "Guidelines on the provision of manual wheelchairs in less-resourced settings" from the World Health Organization (WHO) on user satisfaction, wheelchair skills, and quality of life of Mexican manual wheelchair users. METHODS: 12 wheelchair users with spinal cord injury that received rehabilitation were recruited. Volunteers were provided a wheelchair and cushion following the WHO 8-step guidelines. Assessment of QUEST, WHOQOL-Bref, and WST-Q was performed at the beginning of the study and 12 months later. RESULTS: Significant improvement was observed in terms of satisfaction (QUEST; P = 0.009) after receiving the wheelchair and the foam cushion (QUEST; P = 0.004). WHOQol-Bref did not denote significant differences. For the dimensions assessed by the WST-Q scores, a significant 10.9% improvement was observed in both, capacity (P = 0.022) and performance (P = 0.009). CONCLUSIONS: The application of the WHO 8-step guidelines for wheelchair provision may contribute to increase user satisfaction regarding the wheelchair and cushion devices as well as the prescription process as determined by the QUEST. According to the WST-Q, functional capacity and mobility may also be improved by following the 8-step guidelines.

8.
J Spinal Cord Med ; 46(1): 154-163, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-34612796

RESUMEN

BACKGROUND: Trunk control (TC) constitutes one of the main objectives in the rehabilitation of people with a spinal cord injury (SCI), but there are few clinically validated tests to assess it. Accelerometers have been proposed as sensitive and suitable procedures to assess TC. OBJECTIVE: To evaluate test-retest reliability, construct and criterion validity of accelerometer parameters to assess TC in people with SCI. METHODS: A cross-sectional study of simultaneous application of Clinical Trunk Control Test (CTCT) and accelerometer evaluation was conducted. Accelerometers were placed on the trunks of 27 people with SCI and 15 people without SCI. Reliability was assessed by three repeated measures in random order of selected static and dynamic TC tasks. Acceleration on three axes was analyzed using five metrics. Criterion validity was assessed by analyzing correlation of acceleration to CTCT scores. Construct validity was assessed by analyzing capacity of inertial measurement units (IMU) to differentiate individual's characteristics, ASIA Impairment scale, gait capacity, level of TC, and neurological level of injury. RESULTS: Reliable IMU data were obtained in people with SCI and without SCI, of all accelerometer axes, metrics, and tested items of the CTCT. Reliability of acceleration decreases with the increasing demand for TC tasks. Ten acceleration parameters showed construct and criterion validity. CONCLUSION: Accelerometer parameters are reliable, valid, and sensitive to evaluate TC in people with SCI. SIGNIFICANCE: A set of IMU parameters were validated as reliable and valid measures to evaluate TC, which could be useful for the assessment of progression of people with SCI and clinical interventions.


Asunto(s)
Traumatismos de la Médula Espinal , Humanos , Traumatismos de la Médula Espinal/diagnóstico , Traumatismos de la Médula Espinal/rehabilitación , Reproducibilidad de los Resultados , Estudios Transversales
9.
J Biomech ; 139: 110871, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34839962

RESUMEN

Whole body vibration (WBV) has been suggested as improving skin and blood flow. This study aimed to determine the effect of exposure to WBV on levels of partial transcutaneous oxygen pressure (TcPO2) in the foot of patients with type 2 diabetes (T2D) within the metabolic control goals. A block randomized, open, two-arm, parallel and controlled clinical trial was conducted. Participants recruited from the Center of Comprehensive Care for the Patient with Diabetes were assessed at the National Institute of Rehabilitation, Mexico City. Control group underwent multidisciplinary care for T2D; experimental group, in addition to the comprehensive diabetes care, was exposed to WBV through an exercise program, attending three times a week for a period of 3 months. TcPO2 was measured in the feet of the participants at baseline and after 12 weeks. A sample of 50 volunteers with recently-diagnosed T2D and similar baseline characteristics (demographic, cardiovascular risk, presence of diabetic polyneuropathy, and indicators of glycemic control and TcPO2) was recruited. The experimental group (n = 27) showed a mean value of 47.7 ± 6.1 mmHg in TcPO2, significantly higher (p = 0.028) than the 44.3 ± 7.5 mmHg of control group (n = 23), at the end of intervention. In conclusion, exposure to WBV promoted an increase and a significant 3 mmHg difference in the foot TcPO2 levels between those subjects with T2D that underwent the 12-week exercise program and those not exposed to the treatment.


Asunto(s)
Diabetes Mellitus Tipo 2 , Neuropatías Diabéticas , Diabetes Mellitus Tipo 2/terapia , Pie , Humanos , Oxígeno , Vibración/uso terapéutico
10.
Artif Organs ; 34(3): 230-4, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20447049

RESUMEN

Spasticity has been successfully managed with different treatment modalities or combinations. No information is available on the effectiveness or individual contribution of botulinum toxin type A (BTA) combined with physical and occupational therapy and neuromuscular electrical stimulation to treat spastic upper limb. The purpose of this study was to assess the effects of such treatment and to inform sample-size calculations for a randomized controlled trial. BTA was injected into spastic upper limb muscles of 10 children. They received 10 sessions of physical and occupational therapy followed by 10 sessions of neuromuscular electrical stimulation on the wrist extensors (antagonist muscles). Degree of spasticity using the Modified Ashworth scale, active range of motion, and manual function with the Jebsen hand test, were assessed. Meaningful improvement was observed in hand function posttreatment (P = 0.03). Median spasticity showed a reduction trend and median amplitude of wrist range of motion registered an increase; however, neither of these were significant (P > 0.05). There is evidence of a beneficial effect of the combined treatment. Adequate information has been obtained on main outcome-measurement variability for calculating sample size for a subsequent study to quantify the treatment effect precisely.


Asunto(s)
Toxinas Botulínicas Tipo A/uso terapéutico , Parálisis Cerebral/terapia , Terapia por Estimulación Eléctrica , Fármacos Neuromusculares/uso terapéutico , Terapia Ocupacional , Modalidades de Fisioterapia , Extremidad Superior/fisiopatología , Fenómenos Biomecánicos , Toxinas Botulínicas Tipo A/administración & dosificación , Parálisis Cerebral/diagnóstico , Parálisis Cerebral/fisiopatología , Niño , Preescolar , Terapia Combinada , Evaluación de la Discapacidad , Estudios de Factibilidad , Femenino , Humanos , Inyecciones Intramusculares , Masculino , Espasticidad Muscular , Fármacos Neuromusculares/administración & dosificación , Proyectos Piloto , Rango del Movimiento Articular , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Extremidad Superior/inervación , Muñeca/fisiopatología
11.
Prosthet Orthot Int ; 41(1): 101-105, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27091866

RESUMEN

BACKGROUND AND AIM: The need of comfortable and safe prosthetic systems is an important challenge for both prosthetists and engineers. The aim of this technical note is to demonstrate the use of three-dimensional digital image correlation to evaluate mechanical response of two prosthetic systems under real patient dynamic loads. TECHNIQUE: This note describes the use of three-dimensional digital image correlation method to obtain full-field strain and displacement measurements on the surface of two lower limb prostheses for Chopart amputation. It outlines key points of the measurement protocol and illustrates the analysis of critical regions using data obtained on specific points of interest. DISCUSSION: The results show that the use of three-dimensional digital image correlation can be a tool for the prosthetist to optimize the prosthesis considering features related to the material and design, in order to bear with real patient-specific load conditions. Clinical relevance Three-dimensional digital image correlation can support decision-making on new designs and materials for prosthetics based on quantitative data. Better understanding of mechanical response could also assist prescription for appropriate prosthetic systems.


Asunto(s)
Miembros Artificiales , Imagenología Tridimensional , Diseño de Prótesis , Amputación Quirúrgica , Simulación por Computador , Femenino , Humanos , Estrés Mecánico , Adulto Joven
12.
Med Clin (Barc) ; 148(1): 16-19, 2017 Jan 06.
Artículo en Inglés, Español | MEDLINE | ID: mdl-27871769

RESUMEN

BACKGROUND AND OBJECTIVE: Foot conditions in patients with diabetes mellitus (DM) are major causes of morbidity and disability. Whole body vibration may promote blood circulation in the lower limbs, hence facilitating perfusion and promoting the supply of nutrients and oxygen to comprised tissues. Transcutaneous oxygen levels (TcPO2)>40mmHg in cases of diabetic foot syndrome are associated with a good prognosis in the resolution of ulcers. The objective of this study was to determine whether whole body vibration favors some parameters of interest related to complications associated with the diabetic foot syndrome. PATIENTS AND METHODS: Fifty-four patients with DM were included in a 12-week exercise program based on whole body vibration. Glycemic control was determined on the basis of the patients' levels of glycated hemoglobin (HbA1c); sensitivity and TcPO2 levels of each foot were also recorded. Assessments were performed prior to initiating the whole body vibration program and at the end of it. RESULTS: No significant changes were observed in the patients' HbA1c (P=.442) levels or sensitivity (P=.07). A significant 7mmHg increase (P<.0001; effect size: d=0.53) was observed in the concentration of TcPO2. CONCLUSIONS: Whole body vibration may increase TcPO2 levels with useful implications for the prevention or management of complications associated with restricted blood perfusion in the diabetic foot syndrome.


Asunto(s)
Diabetes Mellitus Tipo 2/complicaciones , Pie Diabético/prevención & control , Oxígeno/metabolismo , Modalidades de Fisioterapia , Piel/metabolismo , Vibración/uso terapéutico , Adulto , Anciano , Biomarcadores/metabolismo , Pie Diabético/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oximetría , Resultado del Tratamiento
13.
Cir Cir ; 81(1): 14-20, 2013.
Artículo en Español | MEDLINE | ID: mdl-23461916

RESUMEN

INTRODUCTION: Cerebral palsy is the most common cause of disability among children. Parent's main concerns are the acquisition and improvement of gait. The aim of this study was to compare long term results of the effect of two modalities of gait training. METHODS: Quantitative measurement of gait and clinical assessment of the gross motor function classification system and Modified Ashworth Scale were perfomed in 14 patients with Cerebral palsy -spastic hemiplegia and randomizedly assigned into two groups of treatment: the first one using a driven gait orthosis (Lokomat(®)) and the second a gait training a long a rail inside a hydrotherapy tank. Measurements and assessments, above described, were performed immediately and one year after the treatment concluded. RESULTS: Significant change was observed in the gross motor function classification system from II to I among children (p=0.042) and a positive correlation between the shape functional of the march and the gross motor function classification system (r = 0.54, p = 0.042). Patients on the Lokomat(®) training improved on gait symmetry over patients on the conventional therapy (p = 0.05). A year after, this intervention showed tendency to kept the gait patterns only on patients treated with the Lokomat(®) CONCLUSION: Benefit obtained with either modality was evident for both groups. However, residual effects observed on the Lokomat group, either in clinical assessment or gait parameters, were more promising than in the conventional therapy. Due to the size of the sample used in this study the results are not conclusive and more research must be done on this subject in long term time horizon.


Asunto(s)
Parálisis Cerebral/fisiopatología , Parálisis Cerebral/rehabilitación , Hemiplejía/fisiopatología , Hemiplejía/rehabilitación , Parálisis Cerebral/complicaciones , Niño , Preescolar , Femenino , Marcha , Hemiplejía/complicaciones , Humanos , Masculino , Estudios Prospectivos , Análisis Espacio-Temporal
14.
Gait Posture ; 32(1): 78-81, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20378352

RESUMEN

OBJECTIVE: To examine temporal and spatial gait parameters in Mexican healthy pediatric subjects to describe normal values which could serve as reference data to eventually compare pathological patterns of the Mexican infant gait. MATERIALS AND METHODS: Descriptive study that analyzed the gait of 120 children (61 boys and 59 girls) between the ages of 6 and 13 years old. Modifying factors (age, gender, and footwear) were recorded and its impact over temporal and spatial gait parameters was assessed. The data was stratified according to the modifying factors. A GAITRite System was used for recording the gait data. RESULTS: Significant differences were noted for the following factors: age and the use of footwear. As the individual advances in age, a decrease in number of steps, normalized velocity, velocity, cadence, normalized cadence, normalized step and stride length was observed. In contrast, step and stride length increased. Use of footwear increased velocity (normalized and non-normalized), normalized cadence, step and stride length (normalized and non-normalized), and percentage of stance GC phase; cadence and swing GC percentage diminished. Gender stratification showed no significant differences in any temporal and spatial gait parameters. There were also found significant differences with those reported for normal adult and pediatric gait in the literature. CONCLUSION: Age and footwear modified gait pattern in the studied sample, while gender apparently did not exert any influence on it.


Asunto(s)
Marcha/fisiología , Adolescente , Envejecimiento/fisiología , Niño , Femenino , Humanos , Masculino , México , Valores de Referencia , Zapatos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA