Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Oncol Pharm Pract ; : 10781552241243360, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38576384

RESUMEN

Drug stability and compatibility are critical factors influencing the cost and logistics of treatment delivery, therapeutic effectiveness, and patient safety. This is particularly significant in the realm of cancer chemotherapeutics, where stability and compatibility studies play a vital role in ensuring rational and safe medicine administration. Oxaliplatin, fluorouracil, and irinotecan, commonly used in various combinations for gastrointestinal cancers, are complemented by co-administration of folinic acid in certain protocols. Notably, some folinic acid preparations include trometamol as an excipient, potentially impacting the stability of the chemotherapeutic agents if infused concomitantly. This study seeks to establish guidelines for oncology multidisciplinary teams, addressing potential risks associated with the combination of trometamol-containing folinic acid and chemotherapeutics. To achieve this, a quantitative questionnaire was distributed to members of the British Oncology Pharmacy Association (BOPA) and non-BOPA members through an online survey. Nineteen healthcare professionals with oncology experience, comprising 18 pharmacists and one nurse, completed the questionnaires. Each participant rated the validity and clarity of statements on a 5-point scale. The Delphi process concluded after the fourth round, consolidating the findings and recommendations from the multidisciplinary team. Twelve recommendations for safe practice have been made.

2.
Appl Environ Microbiol ; 77(24): 8648-55, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22003026

RESUMEN

In this study, we report a whole-genome single nucleotide polymorphism (SNP)-based evolutionary approach to study the epidemiology of a multistate outbreak of Salmonella enterica subsp. enterica serovar Montevideo. This outbreak included 272 cases that occurred in 44 states between July 2009 and April 2010. A case-control study linked the consumption of salami made with contaminated black and red pepper to the outbreak. We sequenced, on the SOLiD System, 47 isolates with XbaI PFGE pattern JIXX01.0011, a common pulsed-field gel electrophoresis (PFGE) pattern associated with isolates from the outbreak. These isolates represented 20 isolates collected from human sources during the period of the outbreak and 27 control isolates collected from human, food, animal, and environmental sources before the outbreak. Based on 253 high-confidence SNPs, we were able to reconstruct a tip-dated molecular clock phylogeny of the isolates and to assign four human isolates to the actual outbreak. We developed an SNP typing assay to rapidly discriminate between outbreak-related cases and non-outbreak-related cases and tested this assay on an extended panel of 112 isolates. These results suggest that only a very small percentage of the human isolates with the outbreak PFGE pattern and obtained during the outbreak period could be attributed to the actual pepper-related outbreak (20%), while the majority (80%) of the putative cases represented background cases. This study demonstrates that next-generation-based SNP typing provides the resolution and accuracy needed for outbreak investigations of food-borne pathogens that cannot be distinguished by currently used subtyping methods.


Asunto(s)
Brotes de Enfermedades , Enfermedades Transmitidas por los Alimentos/epidemiología , Tipificación Molecular/métodos , Polimorfismo de Nucleótido Simple , Infecciones por Salmonella/epidemiología , Salmonella enterica/clasificación , Salmonella enterica/genética , Análisis por Conglomerados , Electroforesis en Gel de Campo Pulsado , Enfermedades Transmitidas por los Alimentos/microbiología , Genotipo , Humanos , Epidemiología Molecular/métodos , Infecciones por Salmonella/microbiología , Salmonella enterica/aislamiento & purificación
3.
Photoacoustics ; 21: 100238, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33473348

RESUMEN

This work describes the design, development and added value of breast-supporting cups to immobilize and position the pendant breast in photoacoustic tomographic imaging. We explain the considerations behind the choice of the material, the shape and sizes of a cup-shaped construct for supporting the breast in water in an imaging tank during full-breast imaging. We provide details of the fabrication, and other processing and testing procedures used. Various experiments were conducted to demonstrate the added value of using these cups. We show that breast movement during a measurement time of four minutes is reduced from maximum 2 mm to 0.1 mm by the use of cups. Further, the presence of the cup, centered in the aperture leading to the imaging tank, ensures that the breast can be reproducibly positioned at the center of the field-of-view of the detection aperture in the tank. Finally, since an accurate delineation of the water-tissue boundary can now be made, the use of the cup enables accurate application of a two-speed of sound model for reconstruction. All in all, we demonstrate that the use of cups to support the breast provides clear enhancement in contrast and resolution of breast images in photoacoustic imaging.

4.
J Biomed Opt ; 27(7)2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34889084

RESUMEN

SIGNIFICANCE: During the development and early testing phases of new photoacoustic (PA) breast imaging systems, several choices need to be made in aspects of system design and measurement sequences. Decision-making can be complex for state-of-the-art systems such as 3D hybrid photoacoustic-ultrasound (PA-US) breast imagers intended for multispectral quantitative imaging. These systems have a large set of design choices and system settings that affect imaging performance in different ways and often require trade-offs. Decisions have to be made carefully as they can strongly influence the imaging performance. AIM: A systematic approach to assess the influence of various choices on the imaging performance in carefully controlled laboratory situations is crucial before starting with human studies. Test objects and phantoms are used for first imaging studies, but most reported structures have a 2D geometry and are not suitable to assess all the image quality characteristics (IQCs) of 3D hybrid PA-US systems. APPROACH: Our work introduces a suite of five test objects designed for hybrid PA-US systems with a 3D detection aperture. We present the test object designs and production protocols and explain how they can be used to study various performance measures. To demonstrate the utility of the developed objects, measurements are made with an existing tomographic PA system. RESULTS: Two test objects were developed for measurements of the US detectors' impulse responses and light distribution on the breast surface. Three others were developed to assess image quality and quantitative accuracy of the PA and US modes. Three of the five objects were imaged to demonstrate their use. CONCLUSIONS: The developed test objects allow one to study influences of various choices in design and system settings. With this, IQCs can be assessed as a function of measurement sequence settings for the PA and US modes in a controlled way. Systematic studies and measurements using these objects will help to optimize various system settings and measurement protocols in laboratory situations before embarking on human studies.

5.
J Biomed Opt ; 24(12): 1-12, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31650741

RESUMEN

We present the Twente Photoacoustic Mammoscope 2, a photoacoustic breast imaging system employing a tomographic configuration. It images one breast pendant inside an imaging tank filled with water while a woman lies prone on a bed. A dual-head laser (755 and 1064 nm) illuminates the breast with one beam directed at the nipple and nine beams directed at the sides. Ultrasound signals are detected using 12 arc-shaped arrays, each curving along the pendant breast. Each array comprises 32 piezocomposite elements each with a center frequency of 1 MHz. The imaging tank and the ultrasound arrays rotate around the breast in steps to obtain additional multiple projections. Three-dimensional images are reconstructed using a filtered backprojection algorithm. The system is described in detail, and measurements on a test object are presented. As part of a preliminary study to assess the system's in vivo performance, the breasts of two healthy volunteers were imaged. These images show the breast contour, the nipple, and the vascular anatomy within the breast. In the nipple of one case, multiple high-intensity "hot spots" are observed, which we suspect are associated with the lactiferous ducts terminating in the nipple.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mama/diagnóstico por imagen , Imagenología Tridimensional , Mamografía/instrumentación , Mamografía/métodos , Técnicas Fotoacústicas , Adulto , Algoritmos , Diseño de Equipo , Femenino , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador , Rayos Láser , Distribución Normal , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA