Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Sensors (Basel) ; 21(20)2021 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-34696104

RESUMEN

Rotary left ventricular assist devices (LVAD) have emerged as a long-term treatment option for patients with advanced heart failure. LVADs need to maintain sufficient physiological perfusion while avoiding left ventricular myocardial damage due to suction at the LVAD inlet. To achieve these objectives, a control algorithm that utilizes a calculated suction index from measured pump flow (SIMPF) is proposed. This algorithm maintained a reference, user-defined SIMPF value, and was evaluated using an in silico model of the human circulatory system coupled to an axial or mixed flow LVAD with 5-10% uniformly distributed measurement noise added to flow sensors. Efficacy of the SIMPF algorithm was compared to a constant pump speed control strategy currently used clinically, and control algorithms proposed in the literature including differential pump speed control, left ventricular end-diastolic pressure control, mean aortic pressure control, and differential pressure control during (1) rest and exercise states; (2) rapid, eight-fold augmentation of pulmonary vascular resistance for (1); and (3) rapid change in physiologic states between rest and exercise. Maintaining SIMPF simultaneously provided sufficient physiological perfusion and avoided ventricular suction. Performance of the SIMPF algorithm was superior to the compared control strategies for both types of LVAD, demonstrating pump independence of the SIMPF algorithm.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos , Humanos , Modelos Cardiovasculares , Succión
2.
Anal Chem ; 92(16): 11288-11296, 2020 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-32689790

RESUMEN

In this study, we report the development of an electrically active solid-liquid interface for the evanescent-wave cavity-ring-down spectroscopic (EW-CRDS) technique to enable spectroelectrochemical investigations of redox events. Because of a high-quality transparent conductive electrode film of indium tin oxide (ITO) coated on the interface of total internal reflection of the EW-CRDS platform, a cavity ring-down time of about 900 ns was obtained allowing spectroelectrochemical studies at solid-liquid interfaces. As a proof-of-concept on the capabilities of the developed platform, measurements were performed to address the effects of an applied electric potential to the adsorption behavior of the redox protein cytochrome c (Cyt-C) onto different interfaces, namely, bare-ITO, 3-aminopropyl triethoxysilane (APTES), and Cyt-C antibody. For each interface, the adsorption and desorption constants, the surface equilibrium constant, the Gibbs free energy of adsorption, and the surface coverage were optically measured by our electrically active EW-CRDS tool. Optical measurements at a set of constant discrete values of the applied electric potential were acquired for kinetic adsorption analysis. Cyclic voltammetry (CV) scans under synchronous optical readout were performed to study the effects of each molecular interface on the redox process of surface-adsorbed protein species. Overall, the experimental results demonstrate the ability of the electro-active EW-CRDS platform to unambiguously measure electrode-driven redox events of surface-confined molecular species at low submonolayer coverages and at a single diffraction-limited spot. Such capability is expected to open several opportunities for the EW-CRDS technique to investigate a variety of electrochemical phenomena at solid-liquid interfaces.

3.
Phys Chem Chem Phys ; 18(30): 20281-9, 2016 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-26667964

RESUMEN

The self-organization of tri-adamantyl (TAB) benzene molecules has been investigated using low temperature scanning tunneling microscopy (LT-STM). The molecular structures have also been studied using molecular modeling. In particular, these calculations have been performed on large areas (1000 nm(2)) from the atomic structure of the molecular building block, combining molecular dynamics (MD) and Monte-Carlo (MC) approaches. These investigations show that the structure of the molecule and its flexibility allow for the formation of different networks as a function of surface coverage. The calculations demonstrate that the stability of the largest structures is obtained through the increase of the interfacial energy induced by the rotation of the adamantyl groups, a behavior whose consequences explain the subtle contrasts observed in the experimental STM images.

4.
Anal Chem ; 86(17): 8541-6, 2014 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-25082792

RESUMEN

Current water quality monitoring for heavy metal contaminants largely results in analytical snapshots at a particular time and place. Therefore, we have been interested in miniaturized and inexpensive sensors suitable for long-term, real-time monitoring of the drinking water distribution grid, industrial wastewater effluents, and even rivers and lakes. Among the biggest challenges for such sensors are the issues of in-field device calibration and sample pretreatment. Previously, we have demonstrated use of coulometric stripping analysis for calibration-free determination of copper and mercury. For more negatively reduced metals, O2 reduction interferes with stripping analysis; hence, most electroanalysis techniques rely on pretreatments to remove dissolved oxygen (DO). Current strategies for portable DO removal offer limited practicality, because of their complexity, and often cause inadvertent sample alterations. Therefore, we have designed an indirect in-line electrochemical DO removal device (EDOR), utilizing a silver cathode to reduce DO in a chamber that is fluidically isolated from the sample stream by an O2-permeable membrane. The resulting concentration gradient supports passive DO diffusion from the sample stream into the deoxygenation chamber. The DO levels in the sample stream were determined by cyclic voltammetry (CV) and amperometry at a custom thin-layer cell (TLC) detector. Results show removal of 98% of the DO in a test sample at flow rates approaching 50 µL/min and power consumption as low as 165 mW h L(-1) at steady state. Besides our specific stripping application, this device is well-suited for LOC applications where miniaturized DO removal and/or regulation are desirable.


Asunto(s)
Técnicas Electroquímicas/métodos , Oxígeno/química , Agua Potable/análisis , Técnicas Electroquímicas/instrumentación , Electrodos , Monitoreo del Ambiente , Técnicas Analíticas Microfluídicas/instrumentación , Oxidación-Reducción
5.
Disabil Rehabil Assist Technol ; : 1-8, 2024 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-38294319

RESUMEN

PURPOSE: Activity-based locomotor training improves intrinsic trunk control in children with spinal cord injury (SCI). To reinforce these improvements, there is a need to develop community integration activities to allow a patient to apply the retrained nervous system at home. One activity that has been explored is rocking in a rocking chair. This paper describes the design, fabrication, and evaluation of a rocking chair for children with SCI. MATERIALS AND METHODS: The Quality Function Deployment (QFD) design process was used. Fundamental needs and features for the rocking chair were defined in a focus group with experienced therapists, and needs were then rated for importance. A House of Quality (HOQ) matrix was developed to correlate needs with design features, and a prototype design was generated. Virtual motion studies and finite element analysis (FEA) were utilized to assess the design. The chair was fabricated and physical testing was performed, including tipping and static and dynamic load assessments. RESULTS AND CONCLUSIONS: The needs identified through the QFD process were categorized into (1) safety, (2) therapeutic, (3) practical and aesthetic, and (4) data to track chair use. Features selected to meet these needs include safety stops, padding, straps, a stable base, armrests, adjustable footrest, and sensors to capture rocking data. FEA showed a factor of safety (FOS) > 5. Physical testing confirmed physical integrity, load-bearing capacity, and stability of the prototype glider rocking chair. The prototype provides a safe tool for further investigation of rocking for promotion of trunk muscle activation in children with SCI.


Rocking in a rocking chair promotes carryover of gained trunk control capacity, from clinic to home in a population that is non-ambulatory.Rocking provides opportunity for self-practice in population with severely compromised capacity.Rocking is a movement that may be performed when other types of movement cannot be readily performed, e.g., resistance exercise, movement against gravity.Rocking creates opportunity for repetitive, voluntary, self-directed movement that is inherently pleasurable and reinforcing.

6.
Anal Chem ; 85(18): 8773-9, 2013 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-23952579

RESUMEN

A major challenge in cardiac tissue engineering is the delivery of hemodynamic mechanical cues that play a critical role in the early development and maturation of cardiomyocytes. Generation of functional cardiac tissue capable of replacing or augmenting cardiac function therefore requires physiologically relevant environments that can deliver complex mechanical cues for cardiomyocyte functional maturation. The goal of this work is the development and validation of a cardiac cell culture model (CCCM) microenvironment that accurately mimics pressure-volume changes seen in the left ventricle and to use this system to achieve cardiac cell maturation under conditions where mechanical loads such as pressure and stretch are gradually increased from the unloaded state to conditions seen in vivo. The CCCM platform, consisting of a cell culture chamber integrated within a flow loop was created to accomplish culture of 10 day chick embryonic ventricular cardiomyocytes subject to 4 days of stimulation (10 mmHg, ∼13% stretch at a frequency of 2 Hz). Results clearly show that CCCM conditioned cardiomyocytes accelerate cardiomyocyte structural and functional maturation in comparison to static unloaded controls as evidenced by increased proliferation, alignment of actin cytoskeleton, bundle-like sarcomeric α-actinin expression, higher pacing beat rate at lower threshold voltages, and increased shortening. These results confirm the CCCM microenvironment can accelerate immature cardiac cell structural and functional maturation for potential cardiac regenerative applications.


Asunto(s)
Técnicas de Cultivo de Célula/métodos , Ventrículos Cardíacos/citología , Miocitos Cardíacos , Ingeniería de Tejidos/métodos , Animales , Embrión de Pollo
7.
Anal Chem ; 83(8): 3170-7, 2011 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-21413699

RESUMEN

The phenotype and function of vascular cells in vivo are influenced by complex mechanical signals generated by pulsatile hemodynamic loading. Physiologically relevant in vitro studies of vascular cells therefore require realistic environments where in vivo mechanical loading conditions can be accurately reproduced. To accomplish a realistic in vivo-like loading environment, we designed and fabricated an Endothelial Cell Culture Model (ECCM) to generate physiological pressure, stretch, and shear stress profiles associated with normal and pathological cardiac flow states. Cells within this system were cultured on a stretchable, thin (∼500 µm) planar membrane within a rectangular flow channel and subject to constant fluid flow. Under pressure, the thin planar membrane assumed a concave shape, representing a segment of the blood vessel wall. Pulsatility was introduced using a programmable pneumatically controlled collapsible chamber. Human aortic endothelial cells (HAECs) were cultured within this system under normal conditions and compared to HAECs cultured under static and "flow only" (13 dyn/cm(2)) control conditions using microscopy. Cells cultured within the ECCM were larger than both controls and assumed an ellipsoidal shape. In contrast to static control control cells, ECCM-cultured cells exhibited alignment of cytoskeletal actin filaments and high and continuous expression levels of ß-catenin indicating an in vivo-like phenotype. In conclusion, design, fabrication, testing, and validation of the ECCM for culture of ECs under realistic pressure, flow, strain, and shear loading seen in normal and pathological conditions was accomplished. The ECCM therefore is an enabling technology that allows for study of ECs under physiologically relevant biomechanical loading conditions in vitro.


Asunto(s)
Técnicas de Cultivo de Célula/métodos , Células Endoteliales/citología , Modelos Biológicos , Técnicas de Cultivo de Célula/instrumentación , Células Cultivadas , Humanos , Presión , Estrés Fisiológico
8.
Phys Chem Chem Phys ; 13(9): 3985-96, 2011 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-21234499

RESUMEN

Using molecular simulation, four types of nanoporous carbons are examined as adsorbents for the separation of CO(2)/CH(4) mixtures at ambient temperature and pressures up to 10 MPa. First, the adsorption selectivity of CO(2) is investigated in carbon slit pores and single-walled carbon nanotube bundles in order to find the optimal pore dimensions for CO(2) separation. Then, the adsorptive properties of the optimized slit pore and nanotube bundle are compared with two realistic nanoporous carbon models: a carbon replica of zeolite Y and an amorphous carbon. For the four carbon models, adsorption isotherms and isosteric heats of adsorption are presented for both pure components and mixtures. Special attention is given to the calculation of excess isotherms and isosteric heats, which are necessary to assess the performance of model nanoporous materials in the context of experimental measurements. From these results, we discuss the impact that variables such as pore size, pore morphology, pressure and mixture composition have on the performance of nanoporous carbons for CO(2) separation.

9.
Microscopy (Oxf) ; 70(3): 278-288, 2021 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-33064828

RESUMEN

Important breakthroughs in far-field imaging techniques have been made since the first demonstrations of stimulated emission depletion (STED) microscopy. To date, the most straightforward and widespread deployment of STED microscopy has used continuous wave (CW) laser beams for both the excitation and depletion of fluorescence emission. A major drawback of the CW STED imaging technique has been photobleaching effects due to the high optical power needed in the depletion beam to reach sub-diffraction resolution. To overcome this hurdle, we have applied a synchronous detection approach based on modulating the excitation laser beam, while keeping the depletion beam at CW operation, and frequency filtering the collected signal with a lock-in amplifier to record solely the super-resolved fluorescence emission. We demonstrate here that such approach allows an important reduction in the optical power of both laser beams that leads to measurable decreases in photobleaching effects in STED microscopy. We report super-resolution images with relatively low powers for both the excitation and depletion beams. In addition, typical unwanted scattering effects and background signal generated from the depletion beam, which invariably arises from mismatches in refractive index in the material composing the sample, are largely reduced by using the modulated STED approach. The capability of acquiring super-resolution images with relatively low power is quite relevant for studying a variety of samples, but particularly important for biological species as exemplified in this work.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Microscopía Fluorescente/métodos , Imagen Óptica/métodos , Fotoblanqueo , Animales , Fluorescencia , Rayos Láser , Ratones , Ratones Transgénicos
10.
ASAIO J ; 67(9): 1026-1035, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-33315663

RESUMEN

Pediatric heart failure (HF) patients have been a historically underserved population for mechanical circulatory support (MCS) therapy. To address this clinical need, we are developing a low cost, universal magnetically levitated extracorporeal system with interchangeable pump heads for pediatric support. Two impeller and pump designs (pump V1 and V2) for the pediatric pump were developed using dimensional analysis techniques and classic pump theory based on defined performance criteria (generated flow, pressure, and impeller diameter). The designs were virtually constructed using computer-aided design (CAD) software and 3D flow and pressure features were analyzed using computational fluid dynamics (CFD) analysis. Simulated pump designs (V1, V2) were operated at higher rotational speeds (~5,000 revolutions per minute [RPM]) than initially estimated (4,255 RPM) to achieve the desired operational point (3.5 L/min flow at 150 mm Hg). Pump V2 outperformed V1 by generating approximately 30% higher pressures at all simulated rotational speeds and at 5% lower priming volume. Simulated hydrodynamic performance (achieved flow and pressure, hydraulic efficiency) of our pediatric pump design, featuring reduced impeller size and priming volume, compares favorably to current commercially available MCS devices.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Niño , Diseño de Equipo , Insuficiencia Cardíaca/cirugía , Humanos , Hidrodinámica , Diseño de Prótesis
11.
Phys Chem Chem Phys ; 12(25): 6632-40, 2010 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-20422115

RESUMEN

The adsorption and diffusion mechanisms of argon at 120 K were examined in a (25,0) single-walled carbon nanotube (SWCNT) bundle using a combination of Grand Canonical Monte Carlo and microcanonical molecular dynamics simulations. Interstices between the SWCNTs provided the most energetically favorable adsorption sites and filled completely at low relative pressure, followed by adsorption in the SWCNTs. We calculated the self-diffusivities from the average mean squared displacements of argon molecules. In both flexible and rigid bundles, we observed a bimodal diffusion mechanism, with single-file diffusion occurring in the interstitial sites and Fickian diffusion in the SWCNTs. Strong system size effects were observed in our simulations. The largest system sizes showed very little influence of the nanotube flexibility on the diffusion of argon even at the lowest pressures studied.

12.
J Chem Phys ; 133(9): 094501, 2010 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-20831318

RESUMEN

The transition from single-file diffusion to Fickian diffusion in narrow cylindrical pores is investigated for systems of rigid single-walled armchair carbon nanotubes, solvated with binary mixtures of Lennard-Jones fluids (Ar/Ne, Ar/Kr, and Ar/Xe). A range of effects is examined including the mixture concentration, the size ratio of the two components, and the nanotube diameter. The transition from single-file to Fickian diffusion in varying carbon nanotube diameters is analyzed in terms of the Fickian self-diffusivity and the single-file mobility of the mixture components. It is found that the single-file to Fickian carbon nanotube transition diameter is a unique property of the individual molecule's diameter and remains unchanged regardless of the mixture composition. In applications of binary mixtures, each component may crossover from single-file to Fickian diffusion in a different carbon nanotube diameter, giving rise to bimodal diffusion in some nanotubes. This transition allows for one species to diffuse in single-file while the other diffuses by a Fickian mechanism, yielding orders of magnitude difference between the self-diffusional rates of the two molecules. This phenomenon might be further extended to alter the diffusional motion of molecules in nanoporous materials.

13.
Anal Chem ; 81(12): 4762-9, 2009 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-19459620

RESUMEN

A scalable and rather inexpensive solution to producing microanalytical systems with "on-chip" three-dimensional (3D) microelectrodes is presented in this study, along with applicability to practical electrochemical (EC) detection scenarios such as preconcentration and interferant removal. This technique to create high-aspect-ratio (as much as 4:1) gold microstructures in constrained areas involved the modification of stud bump geometry with microfabricated silicon molds via an optimized combination of temperature, pressure, and time. The microelectrodes that resulted consisted of an array of square pillars approximately 18 microm tall and 20 microm wide on each side, placed at the end of a microfabricated electrophoresis channel. This technique increased the active surface area of the microelectrodes by as much as a factor of 50, while mass transfer and, consequently, preconcentration collection efficiencies were increased to approximately 100%, compared to approximately 30% efficiency for planar nonmodified microelectrodes (samples that were used included the neurotransmitters dopamine and catechol). The 3D microelectrodes were used both in a stand-alone configuration, for direct EC detection of model catecholamine analytes, and, more interestingly, in dual electrode configurations for EC sample processing prior to detection downstream at a second planar electrode. In particular, the 3D electrodes were shown to be capable of performing coulometry or complete (100%) redox conversion of analyte species over a wide range of concentrations, from 4.3 microM to 4.4 mM, in either plug-flow or continuous-flow formats.


Asunto(s)
Electrodos , Electroforesis por Microchip/instrumentación , Electroforesis por Microchip/métodos , Catecoles/análisis , Dopamina/análisis , Oro/química , Microscopía Electrónica de Rastreo
14.
Methods Mol Biol ; 339: 13-26, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16790863

RESUMEN

In this chapter, a detailed outline delineating the processing steps for microfabricating capillary electrophoresis (CE) with integrated electrochemical detection (ECD) platforms for performing analyte separation and detection is presented to enable persons familiar with microfabrication to enter a cleanroom and fabricate a fully functional Lab-on-a-Chip (LOC) microdevice. The processing steps outlined are appropriate for the production of LOC prototypes using easily obtained glass substrates and common microfabrication techniques. Microfabrication provides a major advantage over existing macro-scale systems by enabling precise control over electrode placement, and integration of all required CE and ECD electrodes directly onto a single substrate with a small footprint. In the processing sequences presented, top and bottom glass substrates are photolithographically patterned and etched using wet chemical processing techniques. The bottom substrate contains seven electrodes required for CE/ECD operation, whereas the top substrate contains the microchannel network. The flush planar electrodes are created using sputter deposition and lift-off processing techniques. Finally, the two glass substrates are thermally bonded to create the final LOC device.


Asunto(s)
Electroforesis por Microchip/instrumentación , Electroquímica/instrumentación , Electrodos , Diseño de Equipo , Vidrio , Fotograbar
15.
Nanoscale ; 6(14): 7991-8001, 2014 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-24905213

RESUMEN

The prediction of supramolecular self-assembly onto solid surfaces is still challenging in many situations of interest for nanoscience. In particular, no previous simulation approach has been capable to simulate large self-assembly patterns of organic molecules over reconstructed surfaces (which have periodicities over large distances) due to the large number of surface atoms and adsorbing molecules involved. Using a novel simulation technique, we report here large scale simulations of the self-assembly patterns of an organic molecule (DIP) over different reconstructions of the Au(111) surface. We show that on particular reconstructions, the molecule-molecule interactions are enhanced in a way that long-range order is promoted. Also, the presence of a distortion in a reconstructed surface pattern not only induces the presence of long-range order but also is able to drive the organization of DIP into two coexisting homochiral domains, in quantitative agreement with STM experiments. On the other hand, only short range order is obtained in other reconstructions of the Au(111) surface. The simulation strategy opens interesting perspectives to tune the supramolecular structure by simulation design and surface engineering if choosing the right molecular building blocks and stabilising the chosen reconstruction pattern.

16.
J Chem Theory Comput ; 9(5): 2161-9, 2013 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-26583710

RESUMEN

We present here the implementation of a code developed for the simulation of the self-assembly of nano objects (SANO). The code has the ability to predict the molecular self-assembly of different structural motifs by tuning the molecular building blocks as well as the metallic substrate. It consists in a two-dimensional grand canonical Monte Carlo (GCMC) approach developed to perform atomistic simulations of thousands of large organic molecules self-assembling on metal surfaces. By computing adsorption isotherms at room temperature and spanning over the characteristic submicrometric scales, we confront the robustness of the approach with three different well-known systems: ZnPcCl8 on Ag(111), CuPcF16 on Au(111), and PTBC on Ag(111). We retrieve respectively their square, oblique, and hexagonal supramolecular tilling. The code incorporates generalized force fields to describe the molecular interactions, which provides transferability to many organic building blocks and metal surfaces. Ultimately, the method is versatile and can be an interesting multiscale approach if one aims to bridge quantum level calculations to the experimental scales and within a treatment in temperature.

17.
Anal Chim Acta ; 803: 47-55, 2013 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-24216196

RESUMEN

Remote unattended sensor networks are increasingly sought after to monitor the drinking water distribution grid, industrial wastewater effluents, and even rivers and lakes. One of the biggest challenges for application of such sensors is the issue of in-field device calibration. With this challenge in mind, we report here the use of anodic stripping coulometry (ASC) as the basis of a calibration-free micro-fabricated electrochemical sensor (CF-MES) for heavy metal determinations. The sensor platform consisted of a photo-lithographically patterned gold working electrode on SiO2 substrate, which was housed within a custom stopped-flow thin-layer cell, with a total volume of 2-4 µL. The behavior of this platform was characterized by fluorescent particle microscopy and electrochemical studies utilizing Fe(CN)6(3-/4-) as a model analyte. The average charge obtained for oxidation of 500 µM ferrocyanide after 60s over a 10 month period was 176 µC, corresponding to a volume of 3.65 µL (RSD = 2.4%). The response of the platform to copper concentrations ranging from 50 to 7500 ppb was evaluated, and the ASC results showed a linear dependence of charge on copper concentrations with excellent reproducibility (RSD ≤ 2.5%) and accuracy for most concentrations (≤ 5-10% error). The platform was also used to determine copper and mercury mixtures, where the total metallic content was measurable with excellent reproducibility (RSD ≤ 4%) and accuracy (≤ 6% error).


Asunto(s)
Cobre/análisis , Técnicas Electroquímicas/instrumentación , Mercurio/análisis , Tecnología de Sensores Remotos/instrumentación , Contaminantes Químicos del Agua/análisis , Calibración , Técnicas Electroquímicas/métodos , Electrodos , Diseño de Equipo , Límite de Detección , Microtecnología/métodos , Tecnología de Sensores Remotos/métodos , Reproducibilidad de los Resultados
18.
Anal Chem ; 75(14): 3643-9, 2003 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-14570221

RESUMEN

Miniaturized, battery-powered, high-voltage power supply, electrochemical (EC) detection, and interface circuits designed for microchip capillary electrophoresis (CE) are described. The dual source CE power supply provides +/- 1 kVDC at 380 microA and can operate continuously for 15 h without recharging. The amperometric EC detection circuit provides electrode potentials of +/-2 VDC and gains of 1, 10, and 100 nA/V. The CE power supply power is connected to the microchip through an interface circuit consisting of two miniature relays, diodes, and resistors. The microchip has equal length buffer and separation channels. This geometry allows the microchip to be controlled from only two reservoirs using fixed dc sources while providing a consistent and stable sample injection volume. The interface circuit also maintains the detection reservoir at ground potential and allows channel currents to be measured likewise. Data are recorded, and the circuits are controlled by a National Instruments signal interface card and software installed in a notebook computer. The combined size (4 in. x 6 in. x 1 in.) and weight (0.35 kg) of the circuits make them ideal for lab-on-a-chip applications. The circuits were tested electrically, by performing separations of dopamine and catechol EC and by laser-induced fluorescence visualization.

19.
Anal Chem ; 74(15): 3690-7, 2002 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-12175155

RESUMEN

Microfabricated lab-on-a-chip devices employing a fully integrated electrochemical (EC) detection system have been developed and evaluated. Both capillary electrophoresis (CE) channels and all CE/EC electrodes were incorporated directly onto glass substrates via traditional microfabrication techniques, including photolithographic patterning, wet chemical etching, DC sputtering, and thermal wafer bonding. Unlike analogous CE/EC devices previously reported, no external electrodes were required, and critical electrode characteristics, including size, shape, and placement on the microchip, were established absolutely by the photolithography process. For the model analytes dopamine and catechol, detection limits in the 4-5 microM range (approximately 200 amol injected) were obtained with the Pt EC electrodes employed here, and devices gave stable analytical performance over months of usage.


Asunto(s)
Electroforesis Capilar/instrumentación , Catecoles/análisis , Dopamina/análisis , Electroforesis Capilar/normas , Microquímica/instrumentación , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA