Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 44(9): 752-761, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36433808

RESUMEN

AIMS: The present study aimed to determine the association between Type 2 diabetes mellitus (T2DM) and third-degree (complete) atrioventricular block. METHODS AND RESULTS: This nationwide nested case-control study included patients older than 18 years, diagnosed with third-degree atrioventricular block between 1 July 1995 and 31 December 2018. Data on medication, comorbidity, and outcomes were collected from Danish registries. Five controls, from the risk set of each case of third-degree atrioventricular block, were matched on age and sex to fit a Cox regression model with time-dependent exposure and time-dependent covariates. Subgroup analysis was conducted with Cox regression models for each subgroup. We located 25 995 cases with third-degree atrioventricular block that were matched with 130 004 controls. The mean age was 76 years and 62% were male. Cases had more T2DM (21% vs. 11%), hypertension (69% vs. 50%), atrial fibrillation (25% vs. 10%), heart failure (20% vs. 6.3%), and myocardial infarction (19% vs. 9.2%), compared with the control group. In Cox regression analysis, adjusting for comorbidities and atrioventricular nodal blocking agents, T2DM was significantly associated with third-degree atrioventricular block (hazard ratio: 1.63, 95% confidence interval: 1.57-1.69). The association remained in several subgroup analyses of diseases also suspected to be associated with third-degree atrioventricular block. There was a significant interaction with comorbidities of interest including hypertension, atrial fibrillation, heart failure, and myocardial infarction. CONCLUSION: In this nationwide study, T2DM was associated with a higher rate of third-degree atrioventricular block compared with matched controls. The association remained independent of atrioventricular nodal blocking agents and other comorbidities known to be associated with third-degree atrioventricular block.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Diabetes Mellitus Tipo 2 , Insuficiencia Cardíaca , Hipertensión , Infarto del Miocardio , Humanos , Masculino , Anciano , Femenino , Estudios de Casos y Controles , Sistema de Registros , Dinamarca
2.
J Cardiovasc Electrophysiol ; 34(3): 519-526, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36640430

RESUMEN

INTRODUCTION: Reconnections to pulmonary vein (PV) triggers of atrial fibrillation (AF) are the primary cause of AF recurrence after PV isolation (PVI) with radiofrequency (RF) or cryoballoon catheter ablation (CRYO), but method-specific contributions to PV reconduction pattern and conductive gap location are incompletely understood. METHODS: The objective of this radiofrequency versus cryoballoon catheter ablation for paroxysmal atrial fibrillation substudy was to determine procedure-specific patterns of PV reconduction in a randomized population with protocol-mandated repeat procedures, irrespective of AF recurrence. Each PV was assessed in turn and PV reconnection sites were identified by high-density electroanatomical mapping and locating the earliest activation site. Gap locations were verified by PV re-isolation. RESULTS: In 98 patients, 81% versus 76% previously isolated PVs remained isolated after CRYO versus RF (risk ratio [RR]: 1.06; 95% confidence interval [CI]: 0.96-1.18; p = .28). There were no significant differences for any PV: left superior PV: 90% versus 80%; left inferior PV: 80% versus 78%; right superior PV: 81% versus 80%, and right inferior PV: 76% versus 73%. For each reconnected PV, 34% of ipsilateral PVs were also reconnected after CRYO compared with 64% after RF (RR: 0.54; 95% CI: 0.32-0.90; p = .01). After RF, gaps were clustered by the carina and adjacent segments, whereas they were more heterogeneously distributed after CRYO. CONCLUSION: Although RF and CRYO produce similar proportions of durably isolated PVs, gap locations appear to develop in procedure-specific patterns. After RF, ipsilateral PV reconduction is more frequent and gap sites cluster by the carina, suggesting that this region should be selectively ablated for more durable PVI.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Criocirugía/métodos , Venas Pulmonares/cirugía , Recurrencia , Fibrilación Atrial/cirugía , Frecuencia Cardíaca , Ablación por Catéter/métodos , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto
3.
J Cardiovasc Electrophysiol ; 34(12): 2434-2442, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37814483

RESUMEN

INTRODUCTION: Atrial tachyarrhythmia recurrence during the blanking period (early ATA) after pulmonary vein isolation (PVI) is associated with an increased risk of later recurrence, but its relationship with pulmonary vein reconduction (PVR) is poorly understood. The objective of the present study was to evaluate the relationship between early ATA and PVR. Second, to provide data on the optimal blanking period by (a) evaluating how the predictive values of ATA for PVR are affected by blanking period duration, and (b) assessing the temporal development in atrial fibrillation (AF) burden. METHODS: In this RACE-AF substudy, 91 patients with paroxysmal AF undergoing PVI randomized to radiofrequency or cryoballoon ablation were included. All patients received an implantable cardiac monitor and underwent a protocol-mandated repeat procedure after 4-6 months for assessment of PVR. ATA ≥ 30 s. ≤ 90 days after PVI constituted early ATA. RESULTS: PVR was found in 37/54 (69%) patients with early ATA and in 11/37 (30%) patients without (p < .001). The positive predictive value of ATA for PVR was independent of blanking period duration (range 0-90 days). In both patients with and without PVR, AF burden was higher in the first month after PVI, but AF burden from the second month was similar to AF burden after the conventional blanking period. CONCLUSION: Early ATA indicates PVR, and the positive predictive value is independent of the blanking period duration. Altogether, the results of this study support substantially shortening the blanking period after PVI for paroxysmal AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Venas Pulmonares/cirugía , Resultado del Tratamiento , Atrios Cardíacos , Taquicardia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Recurrencia
4.
Europace ; 25(2): 425-432, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36480430

RESUMEN

AIMS: Overweight is associated with increased risk of atrial fibrillation (AF), but the impact of overweight and AF recurrence after ablation is less clear. Despite this, an increasing number of AF ablations are carried out in overweight patients. We investigated the impact of body mass index (BMI) on AF recurrence rates after ablation. METHODS AND RESULTS: Through Danish nationwide registers, all patients undergoing first-time AF ablation between 2010 and 2018 were identified. Exposure of interest was BMI. The primary outcome was recurrent AF, defined from either any usage of antiarrhythmic medication, AF hospitalization, cardioversion, or re-ablation. A total of 9188 patients were included. Median age and interquartile range was 64 (60-75) in the normal-weight group and 60 (53-66) in the morbidly obese. There was an increase in comorbidity burden with increasing BMI, including a higher prevalence of heart failure, chronic obstructive pulmonary disease, diabetes, and hypertension. At 1- and 5-year follow ups, recurrence rates of AF increased incrementally by BMI categories. The hazard ratios and 95% confidence intervals of recurrent AF after ablation were 1.15 (1.07-1.23), 1.18 (1.09-1.28), and 1.26 (1.13-1.41) in overweight, obese, and morbidly obese, respectively, compared with normal-weight patients. Procedure duration and X-ray dose exposure also increased with increasing BMI. CONCLUSION: Following AF ablation, recurrence rates of AF increased incrementally with increasing BMI. Therefore, aggressive weight management pre ablation in overweight patients could potentially provide substantial benefits and improve short- and long-term outcomes after ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Obesidad Mórbida , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Estudios de Cohortes , Índice de Masa Corporal , Factores de Riesgo , Sobrepeso/etiología , Sobrepeso/cirugía , Obesidad Mórbida/complicaciones , Obesidad Mórbida/diagnóstico , Obesidad Mórbida/epidemiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia , Dinamarca/epidemiología , Resultado del Tratamiento
5.
Europace ; 25(7)2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37379528

RESUMEN

AIMS: Pulsed field ablation (PFA) is a new, non-thermal ablation modality for pulmonary vein (PV) isolation in patients with atrial fibrillation (AF). The multi-centre EUropean Real World Outcomes with Pulsed Field AblatiOn in Patients with Symptomatic AtRIAl Fibrillation (EU-PORIA) registry sought to determine the safety, efficacy, and learning curve characteristics for the pentaspline, multi-electrode PFA catheter. METHODS AND RESULTS: All-comer AF patients from seven high-volume centres were consecutively enrolled. Procedural and follow-up data were collected. Learning curve effects were analysed by operator ablation experience and primary ablation modality. In total, 1233 patients (61% male, mean age 66 ± 11years, 60% paroxysmal AF) were treated by 42 operators. In 169 patients (14%), additional lesions outside the PVs were performed, most commonly at the posterior wall (n = 127). Median procedure and fluoroscopy times were 58 (interquartile range: 40-87) and 14 (9-21) min, respectively, with no differences due to operator experience. Major complications occurred in 21/1233 procedures (1.7%) including pericardial tamponade (14; 1.1%) and transient ischaemic attack or stroke (n = 7; 0.6%), of which one was fatal. Prior cryoballoon users had less complication. At a median follow-up of 365 (323-386) days, the Kaplan-Meier estimate of arrhythmia-free survival was 74% (80% for paroxysmal and 66% for persistent AF). Freedom from arrhythmia was not influenced by operator experience. In 149 (12%) patients, a repeat procedure was performed due to AF recurrence and 418/584 (72%) PVs were durably isolated. CONCLUSION: The EU-PORIA registry demonstrates a high single-procedure success rate with an excellent safety profile and short procedure times in a real-world, all-comer AF patient population.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Poria , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fluoroscopía , Venas Pulmonares/cirugía , Recurrencia
6.
Am Heart J ; 244: 42-49, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34666012

RESUMEN

BACKGROUND: Electrical cardioversion (ECV) is a common procedure for terminating atrial fibrillation (AF). ECV is associated with brady-arrhythmic events, however, the age-specific risks of clinically significant brady-arrhythmic events are unknown. METHODS: Using Danish nationwide registers, we identified patients with AF at their first non-emergent ECV between 2005 and 2018 and estimated their 30-day risk of brady-arrhythmic events. Moreover, factors associated with increased risks of brady-arrhythmias were identified. Absolute risks were estimated using logistic regression models fitted with natural splines as well as standardization (G-formula). RESULTS: We identified 20,725 eligible patients with a median age of 66 years (IQR 60-72) and most males (73%). The 30-day risks of brady-arrhythmic events after ECV were highly dependent on age with estimated risks ranging from 0.5% (95% CI 0.2-1.7) and 1.2% (95% CI 0.99-1.5) to 2.7% (95% CI 2.1-3.3) and 5.1% (95% CI 2.6-9.7) in patients aged 40, 65, 80, and 90 years, respectively. Factors associated with brady-arrhythmias were generally related to cardiovascular disease (eg, ischemic heart disease, heart failure, valvular AF) or a history of syncope. We found no indications that pre-treatment with anti-arrhythmic drugs conferred increased risks of brady-arrhythmic events (standardized absolute risk difference -0.25% [95% CI -0.67 to 0.17]). CONCLUSIONS: ECV conferred clinically relevant 30-day risks of brady-arrhythmic events, especially in older patients. Anti-arrhythmic drug treatment was not found to increase the risk of brady-arrhythmias. Given the widespread use of ECV, these data should provide insights regarding the potential risks of brady-arrhythmic events.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/métodos , Insuficiencia Cardíaca/complicaciones , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Recurrencia , Resultado del Tratamiento
7.
Europace ; 21(8): 1211-1219, 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-31329849

RESUMEN

AIMS: The safety of omitting implantable cardioverter-defibrillator (ICD) generator replacement in patients with no prior appropriate therapy, comorbid conditions, and advanced age is unclear. The aim was to investigate incidence of appropriate ICD therapy after generator replacement. METHODS AND RESULTS: We identified patients implanted with a primary prevention ICD (n = 4630) from 2007 to 2016, who subsequently underwent an elective ICD generator replacement (n = 670) from the Danish Pacemaker and ICD Register. The data were linked to other databases and evaluated the outcomes of appropriate therapy and death. Predictors of ICD therapy were identified using multivariate Cox regression analyses. A total of 670 patients underwent elective ICD generator replacement. Of these, 197 (29.4%) patients had experienced appropriate therapy in their 1st generator period. During follow-up of 2.0 ± 1.6 years, 95 (14.2%) patients experienced appropriate therapy. Predictors of appropriate therapy in 2nd generator period was low initial left ventricular ejection fraction (≤25%) [hazard ratio (HR) 1.87, confidence interval (CI) 1.13-1.95] and appropriate therapy in 1st generator period (HR 3.95, CI 2.57-6.06). For patients with appropriate therapy in 1st generator period, 4-year incidence of appropriate therapy was 50.6% vs. 16.4% in those without (P < 0.001). Among patients >80 years with no prior appropriate therapy 8.8% of patients experienced appropriate therapy after replacement. Comorbidity burden and advanced age were associated with reduced device utilization after replacement and a high competing risk of death without preceding appropriate therapy. CONCLUSION: A significant residual risk of appropriate therapy in the 2nd generator was present even among patients with advanced age and with a full prior generator period without any appropriate ICD events.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica , Seguridad de Equipos , Implantación de Prótesis , Factores de Edad , Anciano de 80 o más Años , Comorbilidad , Dinamarca/epidemiología , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/métodos , Seguridad de Equipos/métodos , Seguridad de Equipos/estadística & datos numéricos , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Mortalidad , Prevención Primaria/instrumentación , Prevención Primaria/métodos , Prevención Primaria/estadística & datos numéricos , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/métodos
8.
Ann Noninvasive Electrocardiol ; 23(2): e12491, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28940909

RESUMEN

BACKGROUND: Frequent ventricular ectopy on preimplantation Holter has been associated with attenuated benefit from cardiac resynchronization therapy (CRT). However, it is unclear whether ectopic burden measured post-CRT implantation can be utilized to evaluate long-term prognosis. We aimed to describe the association between post-CRT implantation ectopic burden and subsequent risk of clinical outcomes. METHODS: At the 12-month follow-up visit, 24-hour Holter recordings were performed in 698 CRT-D patients from the MADIT-CRT study. The mean number of ventricular premature complexes (VPCs/hour) was calculated. High ectopic burden was defined as >10 VPCs/hour and low burden as ≤10 VPCs/hour. Multivariate Cox proportional hazards models were utilized to assess the association between 12-month ectopic burden and the risk of the end points of heart failure (HF) or death and ventricular tachyarrhythmias (VT/VF). RESULTS: At 12 months, 282 (40%) patients presented with low ectopic burden and 416 (60%) patients presented with high ectopic burden. The 3-year risk of HF/death and VT/VF was lower in patients with a low burden (7% and 8%) and significantly higher (25% and 24%) in patients with high burden. In multivariate analyses, patients with a high ectopic burden had approximately threefold increased risk of both HF/death (HR=2.76 [1.62-4.70], p < .001) and VT/VF (HR=2.79 [1.69-4.58], p < .001). CONCLUSION: In CRT-D patients with mild heart failure, high ectopic burden at 12-month follow-up was associated with a high 3-year risk of HF/death and VT/VF and threefold increased risk as compared to patients with low burden. Ectopic burden at 12 months may be a valuable approach for evaluating long-term prognosis.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Electrocardiografía Ambulatoria/métodos , Insuficiencia Cardíaca/mortalidad , Fibrilación Ventricular/mortalidad , Complejos Prematuros Ventriculares/diagnóstico por imagen , Complejos Prematuros Ventriculares/epidemiología , Anciano , Terapia de Resincronización Cardíaca/efectos adversos , Electrocardiografía/métodos , Femenino , Insuficiencia Cardíaca/etiología , Humanos , Incidencia , Internacionalidad , Masculino , Persona de Mediana Edad , Pronóstico , Medición de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/terapia , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/etiología , Complejos Prematuros Ventriculares/etiología
9.
Artículo en Inglés | MEDLINE | ID: mdl-27572179

RESUMEN

AIMS: Strict left bundle branch block (LBBB) criteria were recently proposed to identify LBBB patients to benefit most from cardiac resynchronization therapy (CRT). The aim of our study was to automate identification of strict LBBB in order to facilitate its broader application. METHODS: We developed a series of algorithms to automatically detect and measure parameters required for strict LBBB criteria and proposed a definition of QRS notch detection. The algorithms were developed using training (n = 20) and validation (n = 592) sets consisting of signal-averaged 12-lead ECGs (1,000 Hz sampling) recorded from 612 LBBB patients from Multicenter Automatic Defibrillator Implantation Trial-CRT. Four trained clinicians independently performed adjudication on 148 different ECGs for comparing automatic and manually adjudicated results, in addition to 13 ECGs for evaluation of intraobserver variability and 32 ECGs for interobserver variability. We assessed the performance of the automated algorithms using manually adjudicated ECGs as references. RESULTS: Overall sensitivity and specificity for detecting strict LBBB were 95% and 86%, respectively. The mean absolute deviation (MAD) of QRS duration and notch/slur locations for the automated method versus the manual method was below 1 ms, and MAD values were lower than 2 ms for interobserver and intraobserver variability. Sensitivity and specificity for detecting notch and slur locations were 87% and 96% for notches and 78% and 90% for slurs using the automatic method. In addition 95% and 93% agreements for notches and 90% and 88% agreements for slurs were reached for intra- and interobserver. CONCLUSION: The proposed algorithms automatically measure QRS features for the diagnosis of strict LBBB. Our study shows good performance in reference to manual results.


Asunto(s)
Bloqueo de Rama/diagnóstico , Electrocardiografía/instrumentación , Electrocardiografía/métodos , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
10.
Artículo en Inglés | MEDLINE | ID: mdl-27629147

RESUMEN

BACKGROUND: The effect of chronic kidney disease (CKD) on benefit from cardiac resynchronization therapy with defibrillator (CRT-D) in reducing ventricular tachyarrhythmia (VTA) risk among mild heart failure (HF) patients is not well understood. METHODS: We evaluated the impact of baseline renal function on VTAs in 1274 left bundle branch block (LBBB) patients enrolled in MADIT-CRT. Two prespecified subgroups were created based on estimated glomerular filtration rate (GFR): GFR <60 (n = 413) and GFR ≥60 ml/min/1.73 m2 (n = 861). Primary end point was ventricular tachycardia/ventricular fibrillation/death (VT/VF/death). Secondary end points were any VT/VF and ventricular tachycardia ≥ 200 bpm or VF (fast VT/VF). RESULTS: There were 413 (32%) LBBB patients presenting with CKD, primarily of moderate severity (GFR mean 48.1 ± 8.3). For patients with and without CKD, CRT-D was associated with lower risk of the primary end point (GFR<60: HR = 0.61, 95% CI: 0.41-0.89, p = .010; GFR≥60: HR = 0.58, 95% CI: 0.52-0.89, p = .005), relative to ICD-only treatment. For patients in both renal function categories, CRT-D in comparison to ICD alone was associated with lower risk of VT/VF (GFR<60: HR = 0.68, 95% CI: 0.42-1.10, p = .113; GFR≥60: HR = 0.65, 95% CI: 0.48-0.88, p = .005) and fast VT/VF (GFR<60: HR = 0.49, 95% CI: 0.25-0.96, p = .038; GFR≥60: HR = 0.55, 95% CI: 0.39-0.80, p = .001), when accounting for competing mortality risk. This effect was independent of CRT-induced reverse remodeling. CONCLUSION: Among mild HF patients with LBBB, those with and without CKD both derived benefit from CRT-D in risk reduction in VTAs, independent of cardiac reverse remodeling.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos , Insuficiencia Renal Crónica/complicaciones , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/diagnóstico , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Taquicardia Ventricular/prevención & control , Resultado del Tratamiento
11.
Eur Heart J ; 36(7): 440-8, 2015 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-25112662

RESUMEN

AIMS: Previous studies on biventricular (BIV) pacing and cardiac resynchronization therapy-defibrillator (CRT-D) efficacy have used arbitrarily chosen BIV pacing percentages, and no study has employed implantable cardioverter defibrillator (ICD) patients as a control group. METHODS AND RESULTS: Using Kaplan-Meier plots, we estimated the threshold of BIV pacing percentage needed for CRT-D to be superior to ICD on the end-point of heart failure (HF) or death in 1219 left bundle branch block (LBBB) patients in the MADIT-CRT trial. Patients were censored at the time of crossover. In multivariable Cox analyses, no difference was seen in the risk of HF/death between ICD and CRT-D patients with BIV pacing ≤90% [HR = 0.78 (0.47-1.30), P = 0.344], and with increasing BIV pacing the risk of HF/death was decreased [CRT-D BIV 91-96% vs. ICD: HR = 0.63 (0.42-0.94), P = 0.024 and CRT-D BIV ≥97% vs. ICD: HR = 0.32 (0.23-0.44), P < 0.001]. The risk of death alone was reduced by 52% in CRT-D patients with BIV ≥97% (HR = 0.48, P < 0.016), when compared with ICD patients. Within the CRT-D group, for every 1 percentage point increase in BIV pacing, the risk of HF/death and death alone significantly decreased by 6 and 10%, respectively. Increasing BIV pacing percentage was associated with significant reductions in left ventricular volume. CONCLUSION: In patients with LBBB, who were in sinus rhythm at enrolment, BIV pacing exceeding 90% was associated with a benefit of CRT-D in HF/death when compared with ICD patients. Furthermore, BIV pacing ≥97% was associated with an even further reduction in HF/death, a significant 52% reduction in death alone, and increased reverse remodelling. Clinical trials.gov identifier: NCT00180271.


Asunto(s)
Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Anciano , Bloqueo de Rama/mortalidad , Terapia de Resincronización Cardíaca/mortalidad , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Remodelación Ventricular/fisiología
12.
J Mol Cell Cardiol ; 79: 203-11, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25479336

RESUMEN

BACKGROUND: The most common inherited cardiac arrhythmia, LQT1, is due to IKs potassium channel mutations and is linked to high risk of adrenergic-triggered cardiac events. We recently showed that although exercise-triggered events are very well treated by ß-blockers for these patients, acute arousal-triggered event rate were not significantly reduced after beta-blocker treatment, suggesting that the mechanisms underlying arousal-triggered arrhythmias may be different from those during exercise. IKs is strongly regulated by ß-adrenergic receptor (ß-AR) signaling, but little is known about the role of α1-AR-mediated regulation. METHODS AND RESULTS: Here we show, using a combination of cellular electrophysiology and computational modeling, that IKs phosphorylation and α1-AR regulation via activation of calcium-dependent PKC isoforms (cPKC) may be a key mechanism to control channel voltage-dependent activation and consequently action potential duration (APD) in response to adrenergic-stimulus. We show that simulated mutation-specific combined adrenergic effects (ß+α) on APD were strongly correlated to acute stress-triggered cardiac event rate for patients while ß-AR effects alone were not. CONCLUSION: We were able to show that calcium-dependent PKC signaling is key to normal QT shortening during acute arousal and when impaired, correlates with increased rate of sudden arousal-triggered cardiac events. Our study suggests that the acute α1-AR-cPKC regulation of IKs is important for QT shortening in "fight-or-flight" response and is linked to decreased risk of sudden emotion/arousal-triggered cardiac events in LQT1 patients.


Asunto(s)
Nivel de Alerta , Calcio/metabolismo , Emociones , Activación del Canal Iónico , Canal de Potasio KCNQ1/metabolismo , Síndrome de QT Prolongado/fisiopatología , Canales de Potasio con Entrada de Voltaje/metabolismo , Proteína Quinasa C/metabolismo , Potenciales de Acción , Proteínas Quinasas Dependientes de AMP Cíclico/metabolismo , Células HEK293 , Humanos , Isoenzimas/metabolismo , Canal de Potasio KCNQ1/genética , Síndrome de QT Prolongado/genética , Proteínas Mutantes/metabolismo , Mutación/genética , Fosforilación , Canales de Potasio con Entrada de Voltaje/genética , Modelos de Riesgos Proporcionales , Receptores Adrenérgicos alfa/metabolismo , Receptores Adrenérgicos beta/metabolismo , Factores de Riesgo , Transducción de Señal
13.
Circulation ; 130(25): 2278-86, 2014 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-25301831

RESUMEN

BACKGROUND: Appropriate guideline criteria for use of implantable cardioverter-defibrillators (ICDs) do not take into account potential recovery of left ventricular ejection fraction (LVEF) in patients treated with CRT-defibrillator. METHODS AND RESULTS: Patients randomized to CRT-defibrillator from the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT) trial who survived and had paired echocardiograms at enrollment and at 12 months (n=752) were included. Patients were evaluated by LVEF recovery in 3 groups (LVEF ≤35% [reference], 36%-50%, and >50%) on outcomes of ventricular tachyarrhythmias (VTAs), VTA ≥200 bpm, ICD shock, heart failure or death, and inappropriate ICD therapy by multivariable Cox models. A total of 7.3% achieved LVEF normalization (>50%). The average follow-up was 2.2±0.8 years. The risk of VTA was reduced in patients with LVEF >50% (hazard ratio [HR], 0.24; 95% confidence interval [CI], 0.07-0.82; P=0.023) and LVEF of 36% to 50% (HR, 0.44; 95% CI, 0.28-0.68; P<0.001). Among patients with LVEF >50%, only 1 patient had VTA ≥200 bpm (HR, 0.16; 95% CI, 0.02-1.51), none were shocked by the ICD, and 2 died of nonarrhythmic causes. The risk of HF or death was reduced with improvements in LVEF (LVEF >50%: HR, 0.29; 95% CI, 0.09-0.97; P=0.045; and LVEF of 36%-50%: HR, 0.44; 95% CI, 0.28-0.69; P<0.001). For inappropriate ICD therapy, no additional risk reduction for LVEF>50% was seen compared with an LVEF of 36% to 50%. A total of 6 factors were associated with LVEF normalization, and patients with all factors present (n=42) did not experience VTAs (positive predictive value, 100%). CONCLUSIONS: Patients who achieve LVEF normalization (>50%) have very low absolute and relative risk of VTAs and a favorable clinical course within 2.2 years of follow-up. Risk of inappropriate ICD therapy is still present, and these patients could be considered for downgrade from CRT-defibrillator to CRT-pacemaker at the time of battery depletion if no VTAs have occurred. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00180271.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables/estadística & datos numéricos , Volumen Sistólico/fisiología , Taquicardia Ventricular/terapia , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda/fisiología , Anciano , Terapia de Resincronización Cardíaca/mortalidad , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Pronóstico , Modelos de Riesgos Proporcionales , Recuperación de la Función/fisiología , Factores de Riesgo , Taquicardia Ventricular/mortalidad , Resultado del Tratamiento , Disfunción Ventricular Izquierda/mortalidad , Fibrilación Ventricular/mortalidad , Fibrilación Ventricular/terapia
14.
Circulation ; 129(5): 545-52, 2014 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-24201303

RESUMEN

BACKGROUND: There is a relative paucity of studies investigating the mechanisms of syncope among heart failure patients with implantable cardioverter-defibrillators, and it is controversial whether nonarrhythmogenic syncope is associated with increased mortality. METHODS AND RESULTS: The Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) randomized 1500 patients to 3 different implantable cardioverter-defibrillator programming arms: (1) Conventional programming with therapy for ventricular tachycardia ≥170 bpm; (2) high-rate cutoff with therapy for ventricular tachycardia ≥200 bpm and a monitoring zone at 170 to 199 bpm, and (3) prolonged 60-second delay with a monitoring zone before therapy. Syncope was a prespecified safety end point that was adjudicated independently. Multivariable Cox models were used to identify risk factors associated with syncope and to analyze subsequent risk of mortality. During follow-up, 64 of 1500 patients (4.3%) had syncope. The incidence of syncope was similar across the 3 treatment arms. Prognostic factors for all-cause syncope included the presence of ischemic cardiomyopathy (hazard ratio [HR], 2.48; 95% confidence interval [CI], 1.42-4.34; P=0.002), previous ventricular arrhythmias (HR, 2.99; 95% CI, 1.18-7.59; P=0.021), left ventricular ejection fraction ≤25% (HR, 1.65; 95% CI, 0.98-2.77; P=0.059), and younger age (by 10 years; HR, 1.25; 95% CI, 1.00-1.52; P=0.046). Syncope was associated with increased risk of death regardless of its cause (arrhythmogenic syncope: HR, 4.51; 95% CI, 1.39-14.64, P=0.012; nonarrhythmogenic syncope: HR, 2.97; 95% CI, 1.07-8.28, P=0.038). CONCLUSIONS: Innovative programming of implantable cardioverter-defibrillators with therapy for ventricular tachycardia ≥200 bpm or a long delay is not associated with increased risk of arrhythmogenic or all-cause syncope, and syncope caused by slow ventricular tachycardias (<200 bpm) is a rare event. The clinical risk factors associated with syncope are related to increased cardiovascular risk profile, and syncope is associated with increased mortality irrespective of the cause. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00947310.


Asunto(s)
Cardiomiopatías/mortalidad , Cardiomiopatías/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/mortalidad , Síncope/mortalidad , Síncope/terapia , Anciano , Cardiomiopatías/fisiopatología , Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Síncope/fisiopatología
15.
Circulation ; 130(21): 1859-67, 2014 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-25274002

RESUMEN

BACKGROUND: Although increased dissemination of automated external defibrillators (AEDs) has been associated with more frequent AED use, the trade-off between the number of deployed AEDs and coverage of cardiac arrests remains unclear. We investigated how volunteer-based AED dissemination affected public cardiac arrest coverage in high- and low-risk areas. METHODS AND RESULTS: All public cardiac arrests (1994-2011) and all registered AEDs (2007-2011) in Copenhagen, Denmark, were identified and geocoded. AED coverage of cardiac arrests was defined as historical arrests ≤100 m from an AED. High-risk areas were defined as those with ≥1 arrest every 2 years and accounted for 1.0% of the total city area. Of 1864 cardiac arrests, 18.0% (n=335) occurred in high-risk areas throughout the study period. From 2007 to 2011, the number of AEDs and the corresponding coverage of cardiac arrests increased from 36 to 552 and from 2.7% to 32.6%, respectively. The corresponding increase for high-risk areas was from 1 to 30 AEDs and coverage from 5.7% to 51.3%, respectively. Since the establishment of the AED network (2007-2011), few arrests (n=55) have occurred ≤100 m from an AED with only 14.5% (n=8) being defibrillated before the arrival of emergency medical services. CONCLUSIONS: Despite the lack of a coordinated public access defibrillation program, the number of AEDs increased 15-fold with a corresponding increase in cardiac arrest coverage from 2.7% to 32.6% over a 5-year period. The highest increase in coverage was observed in high-risk areas (from 5.7% to 51.3%). AED networks can be used as useful tools to optimize AED placement in community settings.


Asunto(s)
Redes Comunitarias/tendencias , Desfibriladores/tendencias , Cardioversión Eléctrica/tendencias , Servicios Médicos de Urgencia/tendencias , Paro Cardíaco Extrahospitalario/terapia , Voluntarios , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Desfibriladores/estadística & datos numéricos , Dinamarca/epidemiología , Cardioversión Eléctrica/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Paro Cardíaco Extrahospitalario/diagnóstico , Paro Cardíaco Extrahospitalario/epidemiología , Estudios Prospectivos , Estudios Retrospectivos , Factores de Tiempo
16.
J Cardiovasc Electrophysiol ; 26(3): 291-9, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25431345

RESUMEN

BACKGROUND: It is unknown whether circadian variation of ventricular tachyarrhythmias (VTA) affects clinical outcome in heart failure patients.  METHODS: A total of 1,790 patients (males 75%) with heart failure, NYHA class I and II and implantable cardioverter defibrillators (ICD) or cardiac resynchronization (CRT-D) enrolled in the MADIT-CRT study were included. Time of first and all VTAs as detected and treated by the device with appropriate ICD therapy (antitachycardia pacing or shock) was evaluated by hours of the day and weekdays and related to all-cause mortality using Cox regression analyses. RESULTS: During a mean follow-up period of 40 months, a total of 3,300 VTA episodes were registered. Of all VTAs recorded, most of them (n = 2977, 90%) occurred in males. Recurrent as well as first VTA episodes were more common in the morning and evening with bimodal peaks from 7:00 to 10:59 (21%) and 18:00-21:59 (23%). VTAs that occurred during morning hours were associated with higher mortality when compared to VTA episodes occurring at other hours (hazard ratios [HR] = 2.07; confidence interval [CI]: 1.135-3.77; P = 0.018) with a significant gender interaction placing females at significantly higher risk of death (HR 6.78; CI 1.55-29.860; P = 0.011) than males (HR 1.79; CI 0.92-3.46; P = 0.086) (interaction P = 0.041) despite an overall lower probability for morning VTA among females (HR 0.32; CI 0.16-0.68; P = 0.003). CONCLUSIONS: The occurrence of VTAs in heart failure patients shows a circadian variation with highest incidence during morning hours that translates into a significant higher risk of all-cause mortality, with significantly higher risk among females than males.


Asunto(s)
Terapia de Resincronización Cardíaca/mortalidad , Ritmo Circadiano , Desfibriladores Implantables , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/terapia , Femenino , Estudios de Seguimiento , Humanos , Masculino , Mortalidad/tendencias , Taquicardia Ventricular/diagnóstico
17.
J Cardiovasc Electrophysiol ; 26(8): 879-884, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25917337

RESUMEN

BACKGROUND: There are limited data whether history of atrial tachyarrhythmia (AT) modifies the risk of inappropriate ICD therapy, or the efficacy of novel ICD programming to reduce inappropriate ICD therapy events. METHODS: In MADIT-RIT, we investigated the effects of novel ICD programming with high-rate cut-off VT zone ≥ 200 bpm (arm B), or 60-second delayed therapy in the VT zone 170-199 bpm (arm C), compared to conventional programming VT zone>170 bpm (arm A) on first inappropriate ICD therapy in those with or those without AT prior to enrollment. RESULTS: In patients with prior AT (n = 203, 14%) there was a higher risk of inappropriate ICD therapy (HR = 2.10, 95% CI: 1.38-3.20, P < 0.001), and inappropriate ICD shock (HR = 2.56, 95% CI: 1.38-4.74, P = 0.003) compared to those with no prior AT. The effects of innovative programming to reduce inappropriate ICD therapy with either high-rate cut-off or delayed VT therapy were similar in patients with prior AT (arm B vs. A HR = 0.11, P < 0.001, arm C vs. A HR = 0.17, P < 0.001), and also in patients without prior AT before enrollment (arm B vs. A HR = 0.15, P < 0.001, arm C vs. A HR = 0.24, P < 0.001, interaction P-values >0.10 for all). CONCLUSIONS: Novel ICD programming with a high-rate cut-off or delayed therapy is equally beneficial to reduce inappropriate ICD therapy in patients with or without prior AT, despite the lower risk of inappropriate ICD therapy in patients without prior AT.


Asunto(s)
Fibrilación Atrial/complicaciones , Aleteo Atrial/complicaciones , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Frecuencia Cardíaca , Prevención Primaria/instrumentación , Falla de Prótesis , Taquicardia Ventricular/terapia , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Aleteo Atrial/diagnóstico , Aleteo Atrial/fisiopatología , Canadá , Muerte Súbita Cardíaca/etiología , Cardioversión Eléctrica/efectos adversos , Europa (Continente) , Femenino , Humanos , Israel , Japón , Masculino , Persona de Mediana Edad , Prevención Primaria/métodos , Diseño de Prótesis , Factores de Riesgo , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
18.
J Cardiovasc Electrophysiol ; 26(4): 424-433, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25546486

RESUMEN

INTRODUCTION: The MADIT-RIT trial demonstrated reduction of inappropriate and appropriate ICD therapies and mortality by high-rate cut-off and 60-second-delayed VT therapy ICD programming in patients with a primary prophylactic ICD indication. The aim of this analysis was to study effects of MADIT-RIT ICD programming in patients with ischemic and nonischemic cardiomyopathy. METHODS AND RESULTS: First and total occurrences of both inappropriate and appropriate ICD therapies were analyzed by multivariate Cox models in 791 (53%) patients with ischemic and 707 (47%) patients with nonischemic cardiomyopathy. Patients with ischemic and nonischemic cardiomyopathy had similar incidence of first inappropriate (9% and 11%, P = 0.21) and first appropriate ICD therapy (11.6% and 14.1%, P = 0.15). Patients with ischemic cardiomyopathy had higher mortality rate (6.1% vs. 3.3%, P = 0.01). MADIT-RIT high-rate cut-off (arm B) and delayed VT therapy ICD programming (arm C) compared with conventional (arm A) ICD programming were associated with a significant risk reduction of first inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy (HR range 0.11-0.34, P < 0.001 for all comparisons). Occurrence of total inappropriate and appropriate ICD therapies was significantly reduced by high-rate cut-off ICD programming and delayed VT therapy ICD programming in both ischemic and nonischemic cardiomyopathy patients. CONCLUSION: High-rate cut-off and delayed VT therapy ICD programming are associated with significant reduction in first and total inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy.


Asunto(s)
Cardiomiopatías/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Falla de Equipo , Isquemia Miocárdica/complicaciones , Taquicardia Ventricular/terapia , Anciano , Cardiomiopatías/diagnóstico , Cardiomiopatías/mortalidad , Cardiomiopatías/fisiopatología , Distribución de Chi-Cuadrado , Muerte Súbita Cardíaca/etiología , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Europa (Continente) , Femenino , Humanos , Israel , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidad , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Factores de Riesgo , Procesamiento de Señales Asistido por Computador , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
19.
J Card Fail ; 21(7): 541-7, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25800548

RESUMEN

BACKGROUND: This study sought to assess the association between medication utilization, outcome, and the efficacy of resynchronization therapy in the MADIT-CRT study. METHODS AND RESULTS: Medication use by patients in the MADIT-CRT study was analyzed. Time-dependent Cox proportional hazard regression analyses were performed to assess differences in hospitalization for heart failure (HF) or death. The greater the efficacy of cardiac resynchronization therapy (CRT) as measured by reduction in left ventricular end-systolic volume (LVESV) and increase in left ventricular ejection fraction (LVEF) between baseline and 1 year of follow-up, the greater the likelihood that patients remained on an angiotensin-converting enzyme inhibitor (ACE-I) or angiotensin receptor blocker (ARB) and avoided use of or reduced treatment with diuretics. Treatment with diuretics was associated with a significantly increased risk of HF hospitalization or death (hazard ratio [HR] 1.87, 95% confidence interval [CI] 1.45-2.41; P < .001). In contrast, treatment with an ACE-I/ARB was associated with a significantly decreased risk of HF hospitalization or death (HR 0.58, 95% CI 0.42-0.80; P = .001). CONCLUSIONS: In HF patients in New York Heart Association functional classes I and II and with wide QRS complexes, efficacy of CRT as measured by improvement in LVESV and LVEF was associated with an increased likelihood of remaining on an ACE-I/ARB and discontinuing diuretic therapy. Discontinuation of diuretics was reflective of improved hemodynamic response to CRT.


Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Antagonistas de Receptores de Angiotensina/uso terapéutico , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Terapia de Resincronización Cardíaca , Diuréticos/uso terapéutico , Insuficiencia Cardíaca , Anciano , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Desfibriladores Implantables , Utilización de Medicamentos/estadística & datos numéricos , Ecocardiografía/métodos , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud , Pronóstico , Modelos de Riesgos Proporcionales , Volumen Sistólico/efectos de los fármacos , Taquicardia Ventricular/etiología , Taquicardia Ventricular/terapia , Resultado del Tratamiento
20.
Europace ; 17(12): 1816-22, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26071234

RESUMEN

AIMS: To understand modes of death and factors associated with the risk for cardiac and non-cardiac deaths in patients with cardiac resynchronization therapy with implantable cardioverter-defibrillator (CRT-D) vs. implantable cardioverter-defibrillator (ICD) therapy, which may help clarify the action and limitations of cardiac resynchronization therapy (CRT) in relieving myocardial dysfunction. METHODS AND RESULTS: In Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT), during 4 years of follow-up, 169 (9.3%) of 1820 patients died of known causes, 108 (63.9%) deemed cardiac, and 61 (36.1%) non-cardiac. In multivariate analysis, increased baseline creatinine was significantly associated with both cardiac and non-cardiac deaths [hazard ratio (HR) 2.97, P < 0.001; HR 1.80, P = 0.035, respectively], as was diabetes (HR 1.79, P = 0.006; HR 1.73, P = 0.038, respectively), and the worst New York Heart Association Class > II more than 3 months prior to enrolment (HR 1.90, P = 0.012; HR 2.46, P = 0.010, respectively). Baseline left atrial volume index was significantly associated only with cardiac mortality (HR 1.28 per 5 unit increase, P < 0.001). Ischaemic cardiomyopathy was associated only with non-cardiac death (HR 3.54, P = 0.001). CRT-D vs. an ICD-only was associated with a reduced risk for cardiac death in patients with left bundle branch block (LBBB) (HR 0.56, P = 0.029) but was associated with an increased risk for non-cardiac death in non-LBBB patients (HR 3.48, P = 0.048). CONCLUSIONS: In MADIT-CRT, two-thirds of the deaths were cardiac and one-third non-cardiac. Many of the same risk factors were associated with both cardiac and non-cardiac mortalities. CRT-D was associated with a reduced risk for cardiac death in LBBB but an increased risk for non-cardiac death in non-LBBB. CLINICAL TRIAL REGISTRATION: Information for the MADIT-CRT main study http://www.clinicaltrials.gov, NCT00180271.


Asunto(s)
Bloqueo de Rama/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca/mortalidad , Cardiomiopatías/terapia , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/mortalidad , Insuficiencia Cardíaca/terapia , Anciano , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/mortalidad , Bloqueo de Rama/fisiopatología , Terapia de Resincronización Cardíaca/efectos adversos , Cardiomiopatías/diagnóstico , Cardiomiopatías/mortalidad , Cardiomiopatías/fisiopatología , Causas de Muerte , Distribución de Chi-Cuadrado , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Electrocardiografía , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Modelos de Riesgos Proporcionales , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA